{"title":"110-230V AC","description":null,"products":[{"product_id":"38-3-way-stainless-steel-motorized-ball-valve-2-wire-ac110-230v-l-type-standard-port-with-manual-function-ip67","title":"3\/8\" 3 Way Stainless Steel Motorized Ball Valve,  2 Wire, AC110-230V,  L Type,  Standard Port with Manual Function,  IP67","description":"\u003cbody\u003e \n\n\n    \u003cstyle\u003e\n        @media only screen and (max-width: 600px) {\n        }\n    \u003c\/style\u003e\n\n\n    \u003cdiv class=\"desktop-only\"\u003e\n        \u003c!--  --\u003e\n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; line-height: 26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 10px; color: black; font-family: Arial;\"\u003eDesigned for durability, this 3-way valve features multiple voltage designs, built-in limit switches, 2-wire control, and a capacitor return for efficient current and water use. Made of robust stainless steel with NPT female thread connection, it's ideal for HVAC, water treatment, and automatic systems. The compact size allows space-efficient integration into pipelines, outperforming multiple one-way valves.\u003c\/p\u003e\n        \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/features-3%20Ways.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n             \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n    \u003ctable style=\"border-collapse: collapse;\n                  border: 0px;\n                  width: 100%;\n                  font-family: Arial;\n                  overflow-x: auto;\n                  background-color: #FFFFFF;\"\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"width: 100%;text-align: left;\n                       padding: 0px;\n                       font-size: 16px;\n                       border: 0;\n                       background-color: #FFFFFF;\"\u003e\n                \u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eSITUATION 1\u003c\/strong\u003e\u003c\/h2\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif14.gif\" style=\"width: 100%;height: 100%;\"\u003e\n            \u003c\/td\u003e\n            \u003ctd style=\"width: 100%;text-align: left;\n                       padding: 0px;\n                       font-size: 16px;\n                       border: 0;\n                       background-color: #FFFFFF;\"\u003e\n                \u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eSITUATION 2 \u003c\/strong\u003e\u003c\/h2\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif13.gif\" style=\"width: 100%;height: 100%;\"\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/table\u003e\n\u003c\/div\u003e\n \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFLOW DIRECTION ( L Type)\u003c\/strong\u003e\u003c\/p\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eSituation 1: \u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eWater enters from the bottom port. With power, it flows from the left port; without power, from the right port.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eSituation 2: \u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eWater enters from both the left and right ports. With power, it flows from the left port to the bottom; without power, from the right port to the bottom.\u003c\/p\u003e \n \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/L-type%281%29.jpg\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n          \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e \n \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV10013\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e2 Wire\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e3\/8\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eO-ring\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eFKM\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eSS304\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e0 - 5 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e110-230V AC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e5 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e3 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e2°C to 90°C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e70,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eStandard\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eActuator Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003ePPO\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e-15°C to 50°C\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eIP67\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/CE.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP67 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYES. The motorized ball valve is made of lead-free stainless steel.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n\u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves shown in this sheet are equipped with a manual operation function. You can manually open or close the valve safely, and this design allows for operation even in the absence of power, providing flexibility and reliability. \u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP67 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n           \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP67. The 6 in IP67 represents complete dust - tightness. The 7 in IP67 indicates protection against water immersion up to 1 meter for 30 minutes. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/IP67-SS304.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/Manual%20for%20Tonhe.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n    \u003cdiv class=\"mobile-only\"\u003e\n        \u003c!--  --\u003e\n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; line-height:26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 0px; color: black; font-family: Arial;\"\u003eDesigned for durability, this 3-way valve features multiple voltage designs, built-in limit switches, 2-wire control, and a capacitor return for efficient current and water use. Made of robust stainless steel with NPT female thread connection, it's ideal for HVAC, water treatment, and automatic systems. The compact size allows space-efficient integration into pipelines, outperforming multiple one-way valves.\u003c\/p\u003e\n            \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/features-3%20Ways-app.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-bottom:10px; margin-top:20px; color: black;\"\u003e\u003cstrong\u003eAPPLICATION\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n    \u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eSITUATION 1\u003c\/strong\u003e\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif14.gif\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n    \u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eSITUATION 2\u003c\/strong\u003e\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif13.gif\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFLOW DIRECTION ( L Type)\u003c\/strong\u003e\u003c\/p\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eSituation 1: \u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eWater enters from the bottom port. With power, it flows from the left port; without power, from the right port.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eSituation 2: \u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eWater enters from both the left and right ports. With power, it flows from the left port to the bottom; without power, from the right port to the bottom.\u003c\/p\u003e \n \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/L-type%281%29.jpg\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n      \u003cp style=\"font-size: 16px; text-align: left; margin-bottom:10px; margin-top:20px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n         \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV10013\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e2 Wire\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e3\/8\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eO-ring\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eFKM\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eSS304\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e0 - 5 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e110-230V AC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e5 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e3 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e2°C to 90°C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e70,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eStandard\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eActuator Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003ePPO\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e-15°C to 50°C\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eIP67\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/CE.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n       \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP67 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYES. The motorized ball valve is made of lead-free stainless steel.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n    \u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                 \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves shown in this sheet are equipped with a manual operation function. You can manually open or close the valve safely, and this design allows for operation even in the absence of power, providing flexibility and reliability. \u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP67 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP67. The 6 in IP67 represents complete dust - tightness. The 7 in IP67 indicates protection against water immersion up to 1 meter for 30 minutes. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/IP67-SS304.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material-APP.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/Manual%20for%20Tonhe.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n    \u003cscript\u003e\n\n        \/\/ (User Agent)\n        const isMobile = window.matchMedia(\"only screen and (max-width: 600px)\").matches;\n        const desktopContent = document.querySelector('.desktop-only');\n        const mobileContent = document.querySelector('.mobile-only');\n\n        if (isMobile) {\n            \/\/ \n            console.log('');\n            \/\/ ，\n            desktopContent.style.display = 'none';\n            mobileContent.style.display = 'block';\n        } else {\n            \/\/ \n            console.log('');            \n            \/\/ ，\n            desktopContent.style.display = 'block';\n            mobileContent.style.display = 'none';\n        }\n    \u003c\/script\u003e\n\n\n\n\u003c\/body\u003e","brand":"U.S. Solid","offers":[{"title":"NPT","offer_id":46918820954367,"sku":"JFMSV10013","price":81.87,"currency_code":"USD","in_stock":true},{"title":"G","offer_id":46918820987135,"sku":"JFMSV10013-G","price":83.77,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/2__93231.1708504343.1280.1280.jpg?v=1731291560"},{"product_id":"1-3-way-brass-motorized-ball-valve-2-wire-ac110-230v-l-type-standard-port-with-manual-function-ip67","title":"1\" 3 Way Brass Motorized Ball Valve,  2 Wire, AC110-230V,  L Type,  Standard Port with Manual Function,  IP67","description":"\u003cbody\u003e \n\n\n    \u003cstyle\u003e\n        @media only screen and (max-width: 600px) {\n        }\n    \u003c\/style\u003e\n\n\n    \u003cdiv class=\"desktop-only\"\u003e\n        \u003c!--  --\u003e\n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; line-height: 26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 10px; color: black; font-family: Arial;\"\u003eDesigned for durability, this 3-way valve features multiple voltage designs, built-in limit switches, 2-wire control, and a capacitor return for efficient current and water use. Made of robust brass with NPT female thread connection, it's ideal for HVAC, water treatment, and automatic systems. The compact size allows space-efficient integration into pipelines, outperforming multiple one-way valves.\u003c\/p\u003e\n        \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/features-3%20Ways.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n             \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n    \u003ctable style=\"border-collapse: collapse;\n                  border: 0px;\n                  width: 100%;\n                  font-family: Arial;\n                  overflow-x: auto;\n                  background-color: #FFFFFF;\"\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"width: 100%;text-align: left;\n                       padding: 0px;\n                       font-size: 16px;\n                       border: 0;\n                       background-color: #FFFFFF;\"\u003e\n                \u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eSITUATION 1\u003c\/strong\u003e\u003c\/h2\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif14.gif\" style=\"width: 100%;height: 100%;\"\u003e\n            \u003c\/td\u003e\n            \u003ctd style=\"width: 100%;text-align: left;\n                       padding: 0px;\n                       font-size: 16px;\n                       border: 0;\n                       background-color: #FFFFFF;\"\u003e\n                \u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eSITUATION 2 \u003c\/strong\u003e\u003c\/h2\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif13.gif\" style=\"width: 100%;height: 100%;\"\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/table\u003e\n\u003c\/div\u003e\n \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFLOW DIRECTION ( L Type)\u003c\/strong\u003e\u003c\/p\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eSituation 1: \u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eWater enters from the bottom port. With power, it flows from the left port; without power, from the right port.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eSituation 2: \u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eWater enters from both the left and right ports. With power, it flows from the left port to the bottom; without power, from the right port to the bottom.\u003c\/p\u003e \n \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/L-type%281%29.jpg\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n          \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e \n \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV10017\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e2 Wire\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eO-ring\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eFKM\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eBrass\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e0 - 5 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e110-230V AC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e5 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e3 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e2°C to 90°C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e70,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eStandard\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eActuator Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003ePPO\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e-15°C to 50°C\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eIP67\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/CE.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP67 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNO. This product can expose you to chemicals including lead, which is known to the State of California to cause cancer and birth defects or other reproductive harm.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n\u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves shown in this sheet are equipped with a manual operation function. You can manually open or close the valve safely, and this design allows for operation even in the absence of power, providing flexibility and reliability. \u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP67 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n           \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP67. The 6 in IP67 represents complete dust - tightness. The 7 in IP67 indicates protection against water immersion up to 1 meter for 30 minutes. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/IP67.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/Manual%20for%20Tonhe.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n    \u003cdiv class=\"mobile-only\"\u003e\n        \u003c!--  --\u003e\n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; line-height:26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 0px; color: black; font-family: Arial;\"\u003eDesigned for durability, this 3-way valve features multiple voltage designs, built-in limit switches, 2-wire control, and a capacitor return for efficient current and water use. Made of robust brass with NPT female thread connection, it's ideal for HVAC, water treatment, and automatic systems. The compact size allows space-efficient integration into pipelines, outperforming multiple one-way valves.\u003c\/p\u003e\n            \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/features-3%20Ways-app.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-bottom:10px; margin-top:20px; color: black;\"\u003e\u003cstrong\u003eAPPLICATION\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n    \u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eSITUATION 1\u003c\/strong\u003e\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif14.gif\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n    \u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eSITUATION 2\u003c\/strong\u003e\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif13.gif\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFLOW DIRECTION ( L Type)\u003c\/strong\u003e\u003c\/p\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eSituation 1: \u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eWater enters from the bottom port. With power, it flows from the left port; without power, from the right port.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eSituation 2: \u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eWater enters from both the left and right ports. With power, it flows from the left port to the bottom; without power, from the right port to the bottom.\u003c\/p\u003e \n \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/L-type%281%29.jpg\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n      \u003cp style=\"font-size: 16px; text-align: left; margin-bottom:10px; margin-top:20px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n         \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV10017\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e2 Wire\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eO-ring\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eFKM\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eBrass\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e0 - 5 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e110-230V AC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e5 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e3 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e2°C to 90°C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e70,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eStandard\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eActuator Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003ePPO\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e-15°C to 50°C\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eIP67\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/CE.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n       \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP67 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNO. This product can expose you to chemicals including lead, which is known to the State of California to cause cancer and birth defects or other reproductive harm.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n    \u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                 \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves shown in this sheet are equipped with a manual operation function. You can manually open or close the valve safely, and this design allows for operation even in the absence of power, providing flexibility and reliability. \u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP67 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP67. The 6 in IP67 represents complete dust - tightness. The 7 in IP67 indicates protection against water immersion up to 1 meter for 30 minutes. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/IP67.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material-APP.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/Manual%20for%20Tonhe.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n    \u003cscript\u003e\n\n        \/\/ (User Agent)\n        const isMobile = window.matchMedia(\"only screen and (max-width: 600px)\").matches;\n        const desktopContent = document.querySelector('.desktop-only');\n        const mobileContent = document.querySelector('.mobile-only');\n\n        if (isMobile) {\n            \/\/ \n            console.log('');\n            \/\/ ，\n            desktopContent.style.display = 'none';\n            mobileContent.style.display = 'block';\n        } else {\n            \/\/ \n            console.log('');            \n            \/\/ ，\n            desktopContent.style.display = 'block';\n            mobileContent.style.display = 'none';\n        }\n    \u003c\/script\u003e\n\n\n\n\u003c\/body\u003e","brand":"U.S. Solid","offers":[{"title":"NPT","offer_id":46918813384959,"sku":"JFMSV10017","price":94.49,"currency_code":"USD","in_stock":true},{"title":"G","offer_id":46918813417727,"sku":"JFMSV10017-G","price":95.49,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/1__05732.1708505661.1280.1280.jpg?v=1731291565"},{"product_id":"34-3-way-brass-motorized-ball-valve-2-wire-ac110-230v-l-type-standard-port-with-manual-function-ip67","title":"3\/4\" 3 Way Brass Motorized Ball Valve,  2 Wire, AC110-230V,  L Type,  Standard Port with Manual Function,  IP67","description":"\u003cbody\u003e \n\n\n    \u003cstyle\u003e\n        @media only screen and (max-width: 600px) {\n        }\n    \u003c\/style\u003e\n\n\n    \u003cdiv class=\"desktop-only\"\u003e\n        \u003c!--  --\u003e\n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; line-height: 26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 10px; color: black; font-family: Arial;\"\u003eDesigned for durability, this 3-way valve features multiple voltage designs, built-in limit switches, 2-wire control, and a capacitor return for efficient current and water use. Made of robust brass with NPT female thread connection, it's ideal for HVAC, water treatment, and automatic systems. The compact size allows space-efficient integration into pipelines, outperforming multiple one-way valves.\u003c\/p\u003e\n        \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/features-3%20Ways.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n             \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n    \u003ctable style=\"border-collapse: collapse;\n                  border: 0px;\n                  width: 100%;\n                  font-family: Arial;\n                  overflow-x: auto;\n                  background-color: #FFFFFF;\"\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"width: 100%;text-align: left;\n                       padding: 0px;\n                       font-size: 16px;\n                       border: 0;\n                       background-color: #FFFFFF;\"\u003e\n                \u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eSITUATION 1\u003c\/strong\u003e\u003c\/h2\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif14.gif\" style=\"width: 100%;height: 100%;\"\u003e\n            \u003c\/td\u003e\n            \u003ctd style=\"width: 100%;text-align: left;\n                       padding: 0px;\n                       font-size: 16px;\n                       border: 0;\n                       background-color: #FFFFFF;\"\u003e\n                \u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eSITUATION 2 \u003c\/strong\u003e\u003c\/h2\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif13.gif\" style=\"width: 100%;height: 100%;\"\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/table\u003e\n\u003c\/div\u003e\n \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFLOW DIRECTION ( L Type)\u003c\/strong\u003e\u003c\/p\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eSituation 1: \u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eWater enters from the bottom port. With power, it flows from the left port; without power, from the right port.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eSituation 2: \u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eWater enters from both the left and right ports. With power, it flows from the left port to the bottom; without power, from the right port to the bottom.\u003c\/p\u003e \n \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/L-type%281%29.jpg\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n          \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e \n \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV10016\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e2 Wire\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e3\/4\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eO-ring\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eFKM\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eBrass\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e0 - 5 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e110-230V AC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e5 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e3 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e2°C to 90°C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e70,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eStandard\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eActuator Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003ePPO\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e-15°C to 50°C\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eIP67\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/CE.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP67 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNO. This product can expose you to chemicals including lead, which is known to the State of California to cause cancer and birth defects or other reproductive harm.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n\u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves shown in this sheet are equipped with a manual operation function. You can manually open or close the valve safely, and this design allows for operation even in the absence of power, providing flexibility and reliability. \u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP67 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n           \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP67. The 6 in IP67 represents complete dust - tightness. The 7 in IP67 indicates protection against water immersion up to 1 meter for 30 minutes. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/IP67.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/Manual%20for%20Tonhe.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n    \u003cdiv class=\"mobile-only\"\u003e\n        \u003c!--  --\u003e\n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; line-height:26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 0px; color: black; font-family: Arial;\"\u003eDesigned for durability, this 3-way valve features multiple voltage designs, built-in limit switches, 2-wire control, and a capacitor return for efficient current and water use. Made of robust brass with NPT female thread connection, it's ideal for HVAC, water treatment, and automatic systems. The compact size allows space-efficient integration into pipelines, outperforming multiple one-way valves.\u003c\/p\u003e\n            \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/features-3%20Ways-app.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-bottom:10px; margin-top:20px; color: black;\"\u003e\u003cstrong\u003eAPPLICATION\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n    \u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eSITUATION 1\u003c\/strong\u003e\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif14.gif\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n    \u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eSITUATION 2\u003c\/strong\u003e\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif13.gif\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFLOW DIRECTION ( L Type)\u003c\/strong\u003e\u003c\/p\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eSituation 1: \u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eWater enters from the bottom port. With power, it flows from the left port; without power, from the right port.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eSituation 2: \u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eWater enters from both the left and right ports. With power, it flows from the left port to the bottom; without power, from the right port to the bottom.\u003c\/p\u003e \n \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/L-type%281%29.jpg\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n      \u003cp style=\"font-size: 16px; text-align: left; margin-bottom:10px; margin-top:20px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n         \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV10016\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e2 Wire\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e3\/4\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eO-ring\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eFKM\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eBrass\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e0 - 5 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e110-230V AC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e5 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e3 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e2°C to 90°C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e70,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eStandard\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eActuator Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003ePPO\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e-15°C to 50°C\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eIP67\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/CE.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n       \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP67 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNO. This product can expose you to chemicals including lead, which is known to the State of California to cause cancer and birth defects or other reproductive harm.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n    \u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                 \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves shown in this sheet are equipped with a manual operation function. You can manually open or close the valve safely, and this design allows for operation even in the absence of power, providing flexibility and reliability. \u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP67 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP67. The 6 in IP67 represents complete dust - tightness. The 7 in IP67 indicates protection against water immersion up to 1 meter for 30 minutes. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/IP67.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material-APP.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/Manual%20for%20Tonhe.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n    \u003cscript\u003e\n\n        \/\/ (User Agent)\n        const isMobile = window.matchMedia(\"only screen and (max-width: 600px)\").matches;\n        const desktopContent = document.querySelector('.desktop-only');\n        const mobileContent = document.querySelector('.mobile-only');\n\n        if (isMobile) {\n            \/\/ \n            console.log('');\n            \/\/ ，\n            desktopContent.style.display = 'none';\n            mobileContent.style.display = 'block';\n        } else {\n            \/\/ \n            console.log('');            \n            \/\/ ，\n            desktopContent.style.display = 'block';\n            mobileContent.style.display = 'none';\n        }\n    \u003c\/script\u003e\n\n\n\n\u003c\/body\u003e","brand":"U.S. Solid","offers":[{"title":"NPT","offer_id":46918812860671,"sku":"JFMSV10016","price":87.74,"currency_code":"USD","in_stock":true},{"title":"G","offer_id":46918812893439,"sku":"JFMSV10016-G","price":88.49,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/1__07480.1708505431.1280.1280.jpg?v=1731291563"},{"product_id":"12-3-way-brass-motorized-ball-valve-2-wire-ac110-230v-l-type-standard-port-with-manual-function-ip67","title":"1\/2\" 3 Way Brass Motorized Ball Valve,  2 Wire, AC110-230V,  L Type,  Standard Port with Manual Function,  IP67","description":"\u003cbody\u003e \n\n\n    \u003cstyle\u003e\n        @media only screen and (max-width: 600px) {\n        }\n    \u003c\/style\u003e\n\n\n    \u003cdiv class=\"desktop-only\"\u003e\n        \u003c!--  --\u003e\n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; line-height: 26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 10px; color: black; font-family: Arial;\"\u003eDesigned for durability, this 3-way valve features multiple voltage designs, built-in limit switches, 2-wire control, and a capacitor return for efficient current and water use. Made of robust brass with NPT female thread connection, it's ideal for HVAC, water treatment, and automatic systems. The compact size allows space-efficient integration into pipelines, outperforming multiple one-way valves.\u003c\/p\u003e\n        \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/features-3%20Ways.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n             \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n    \u003ctable style=\"border-collapse: collapse;\n                  border: 0px;\n                  width: 100%;\n                  font-family: Arial;\n                  overflow-x: auto;\n                  background-color: #FFFFFF;\"\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"width: 100%;text-align: left;\n                       padding: 0px;\n                       font-size: 16px;\n                       border: 0;\n                       background-color: #FFFFFF;\"\u003e\n                \u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eSITUATION 1\u003c\/strong\u003e\u003c\/h2\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif14.gif\" style=\"width: 100%;height: 100%;\"\u003e\n            \u003c\/td\u003e\n            \u003ctd style=\"width: 100%;text-align: left;\n                       padding: 0px;\n                       font-size: 16px;\n                       border: 0;\n                       background-color: #FFFFFF;\"\u003e\n                \u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eSITUATION 2 \u003c\/strong\u003e\u003c\/h2\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif13.gif\" style=\"width: 100%;height: 100%;\"\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/table\u003e\n\u003c\/div\u003e\n \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFLOW DIRECTION ( L Type)\u003c\/strong\u003e\u003c\/p\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eSituation 1: \u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eWater enters from the bottom port. With power, it flows from the left port; without power, from the right port.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eSituation 2: \u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eWater enters from both the left and right ports. With power, it flows from the left port to the bottom; without power, from the right port to the bottom.\u003c\/p\u003e \n \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/L-type%281%29.jpg\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n          \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e \n \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV10015\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e2 Wire\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1\/2\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eO-ring\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eFKM\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eBrass\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e0 - 5 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e110-230V AC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e5 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e3 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e2°C to 90°C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e70,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eStandard\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eActuator Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003ePPO\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e-15°C to 50°C\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eIP67\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/CE.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP67 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNO. This product can expose you to chemicals including lead, which is known to the State of California to cause cancer and birth defects or other reproductive harm.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n\u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves shown in this sheet are equipped with a manual operation function. You can manually open or close the valve safely, and this design allows for operation even in the absence of power, providing flexibility and reliability. \u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP67 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n           \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP67. The 6 in IP67 represents complete dust - tightness. The 7 in IP67 indicates protection against water immersion up to 1 meter for 30 minutes. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/IP67.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/Manual%20for%20Tonhe.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n    \u003cdiv class=\"mobile-only\"\u003e\n        \u003c!--  --\u003e\n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; line-height:26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 0px; color: black; font-family: Arial;\"\u003eDesigned for durability, this 3-way valve features multiple voltage designs, built-in limit switches, 2-wire control, and a capacitor return for efficient current and water use. Made of robust brass with NPT female thread connection, it's ideal for HVAC, water treatment, and automatic systems. The compact size allows space-efficient integration into pipelines, outperforming multiple one-way valves.\u003c\/p\u003e\n            \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/features-3%20Ways-app.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-bottom:10px; margin-top:20px; color: black;\"\u003e\u003cstrong\u003eAPPLICATION\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n    \u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eSITUATION 1\u003c\/strong\u003e\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif14.gif\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n    \u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eSITUATION 2\u003c\/strong\u003e\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif13.gif\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFLOW DIRECTION ( L Type)\u003c\/strong\u003e\u003c\/p\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eSituation 1: \u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eWater enters from the bottom port. With power, it flows from the left port; without power, from the right port.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eSituation 2: \u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eWater enters from both the left and right ports. With power, it flows from the left port to the bottom; without power, from the right port to the bottom.\u003c\/p\u003e \n \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/L-type%281%29.jpg\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n      \u003cp style=\"font-size: 16px; text-align: left; margin-bottom:10px; margin-top:20px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n         \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV10015\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e2 Wire\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1\/2\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eO-ring\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eFKM\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eBrass\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e0 - 5 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e110-230V AC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e5 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e3 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e2°C to 90°C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e70,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eStandard\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eActuator Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003ePPO\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e-15°C to 50°C\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eIP67\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/CE.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n       \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP67 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNO. This product can expose you to chemicals including lead, which is known to the State of California to cause cancer and birth defects or other reproductive harm.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n    \u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                 \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves shown in this sheet are equipped with a manual operation function. You can manually open or close the valve safely, and this design allows for operation even in the absence of power, providing flexibility and reliability. \u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP67 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP67. The 6 in IP67 represents complete dust - tightness. The 7 in IP67 indicates protection against water immersion up to 1 meter for 30 minutes. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/IP67.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material-APP.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/Manual%20for%20Tonhe.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n    \u003cscript\u003e\n\n        \/\/ (User Agent)\n        const isMobile = window.matchMedia(\"only screen and (max-width: 600px)\").matches;\n        const desktopContent = document.querySelector('.desktop-only');\n        const mobileContent = document.querySelector('.mobile-only');\n\n        if (isMobile) {\n            \/\/ \n            console.log('');\n            \/\/ ，\n            desktopContent.style.display = 'none';\n            mobileContent.style.display = 'block';\n        } else {\n            \/\/ \n            console.log('');            \n            \/\/ ，\n            desktopContent.style.display = 'block';\n            mobileContent.style.display = 'none';\n        }\n    \u003c\/script\u003e\n\n\n\n\u003c\/body\u003e","brand":"U.S. Solid","offers":[{"title":"NPT","offer_id":46918811713791,"sku":"JFMSV10015","price":78.98,"currency_code":"USD","in_stock":true},{"title":"G","offer_id":46918811746559,"sku":"JFMSV10015-G","price":79.49,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/1__66790.1708505300.1280.1280.jpg?v=1731291562"},{"product_id":"12-3-way-stainless-steel-motorized-ball-valve-2-wire-ac110-230v-l-type-standard-port-with-manual-function-ip67","title":"1\/2\" 3 Way Stainless Steel Motorized Ball Valve,  2 Wire, AC110-230V,  L Type,  Standard Port with Manual Function,  IP67","description":"\u003cbody\u003e \n\n\n    \u003cstyle\u003e\n        @media only screen and (max-width: 600px) {\n        }\n    \u003c\/style\u003e\n\n\n    \u003cdiv class=\"desktop-only\"\u003e\n        \u003c!--  --\u003e\n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; line-height: 26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 10px; color: black; font-family: Arial;\"\u003eDesigned for durability, this 3-way valve features multiple voltage designs, built-in limit switches, 2-wire control, and a capacitor return for efficient current and water use. Made of robust stainless steel with NPT female thread connection, it's ideal for HVAC, water treatment, and automatic systems. The compact size allows space-efficient integration into pipelines, outperforming multiple one-way valves.\u003c\/p\u003e\n        \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/features-3%20Ways.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n             \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n    \u003ctable style=\"border-collapse: collapse;\n                  border: 0px;\n                  width: 100%;\n                  font-family: Arial;\n                  overflow-x: auto;\n                  background-color: #FFFFFF;\"\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"width: 100%;text-align: left;\n                       padding: 0px;\n                       font-size: 16px;\n                       border: 0;\n                       background-color: #FFFFFF;\"\u003e\n                \u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eSITUATION 1\u003c\/strong\u003e\u003c\/h2\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif14.gif\" style=\"width: 100%;height: 100%;\"\u003e\n            \u003c\/td\u003e\n            \u003ctd style=\"width: 100%;text-align: left;\n                       padding: 0px;\n                       font-size: 16px;\n                       border: 0;\n                       background-color: #FFFFFF;\"\u003e\n                \u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eSITUATION 2 \u003c\/strong\u003e\u003c\/h2\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif13.gif\" style=\"width: 100%;height: 100%;\"\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/table\u003e\n\u003c\/div\u003e\n \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFLOW DIRECTION ( L Type)\u003c\/strong\u003e\u003c\/p\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eSituation 1: \u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eWater enters from the bottom port. With power, it flows from the left port; without power, from the right port.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eSituation 2: \u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eWater enters from both the left and right ports. With power, it flows from the left port to the bottom; without power, from the right port to the bottom.\u003c\/p\u003e \n \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/L-type%281%29.jpg\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n          \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e \n \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV10006\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e2 Wire\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1\/2\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eO-ring\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eFKM\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eSS304\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e0 - 5 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e110-230V AC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e5 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e3 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e2°C to 90°C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e70,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eStandard\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eActuator Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003ePPO\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e-15°C to 50°C\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eIP67\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/CE.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP67 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYES. The motorized ball valve is made of lead-free stainless steel.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n\u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves shown in this sheet are equipped with a manual operation function. You can manually open or close the valve safely, and this design allows for operation even in the absence of power, providing flexibility and reliability. \u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP67 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n           \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP67. The 6 in IP67 represents complete dust - tightness. The 7 in IP67 indicates protection against water immersion up to 1 meter for 30 minutes. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/IP67-SS304.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/Manual%20for%20Tonhe.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n    \u003cdiv class=\"mobile-only\"\u003e\n        \u003c!--  --\u003e\n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; line-height:26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 0px; color: black; font-family: Arial;\"\u003eDesigned for durability, this 3-way valve features multiple voltage designs, built-in limit switches, 2-wire control, and a capacitor return for efficient current and water use. Made of robust stainless steel with NPT female thread connection, it's ideal for HVAC, water treatment, and automatic systems. The compact size allows space-efficient integration into pipelines, outperforming multiple one-way valves.\u003c\/p\u003e\n            \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/features-3%20Ways-app.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-bottom:10px; margin-top:20px; color: black;\"\u003e\u003cstrong\u003eAPPLICATION\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n    \u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eSITUATION 1\u003c\/strong\u003e\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif14.gif\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n    \u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eSITUATION 2\u003c\/strong\u003e\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif13.gif\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFLOW DIRECTION ( L Type)\u003c\/strong\u003e\u003c\/p\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eSituation 1: \u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eWater enters from the bottom port. With power, it flows from the left port; without power, from the right port.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eSituation 2: \u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eWater enters from both the left and right ports. With power, it flows from the left port to the bottom; without power, from the right port to the bottom.\u003c\/p\u003e \n \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/L-type%281%29.jpg\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n      \u003cp style=\"font-size: 16px; text-align: left; margin-bottom:10px; margin-top:20px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n         \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV10006\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e2 Wire\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1\/2\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eO-ring\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eFKM\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eSS304\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e0 - 5 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e110-230V AC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e5 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e3 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e2°C to 90°C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e70,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eStandard\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eActuator Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003ePPO\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e-15°C to 50°C\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eIP67\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/CE.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n       \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP67 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYES. The motorized ball valve is made of lead-free stainless steel.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n    \u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                 \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves shown in this sheet are equipped with a manual operation function. You can manually open or close the valve safely, and this design allows for operation even in the absence of power, providing flexibility and reliability. \u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP67 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP67. The 6 in IP67 represents complete dust - tightness. The 7 in IP67 indicates protection against water immersion up to 1 meter for 30 minutes. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/IP67-SS304.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material-APP.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/Manual%20for%20Tonhe.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n    \u003cscript\u003e\n\n        \/\/ (User Agent)\n        const isMobile = window.matchMedia(\"only screen and (max-width: 600px)\").matches;\n        const desktopContent = document.querySelector('.desktop-only');\n        const mobileContent = document.querySelector('.mobile-only');\n\n        if (isMobile) {\n            \/\/ \n            console.log('');\n            \/\/ ，\n            desktopContent.style.display = 'none';\n            mobileContent.style.display = 'block';\n        } else {\n            \/\/ \n            console.log('');            \n            \/\/ ，\n            desktopContent.style.display = 'block';\n            mobileContent.style.display = 'none';\n        }\n    \u003c\/script\u003e\n\n\n\n\u003c\/body\u003e","brand":"U.S. Solid","offers":[{"title":"NPT","offer_id":46918810501375,"sku":"JFMSV10006","price":111.77,"currency_code":"USD","in_stock":true},{"title":"G","offer_id":46918810534143,"sku":"JFMSV10006-G","price":103.77,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/1__47292.1708503398.1280.1280.jpg?v=1731291565"},{"product_id":"38-3-way-brass-motorized-ball-valve-2-wire-ac110-230v-l-type-standard-port-with-manual-function-ip67","title":"3\/8\" 3 Way Brass Motorized Ball Valve,  2 Wire,  AC110-230V,  L Type,  Standard Port with Manual Function,  IP67","description":"\u003cbody\u003e \n\n\n    \u003cstyle\u003e\n        @media only screen and (max-width: 600px) {\n        }\n    \u003c\/style\u003e\n\n\n    \u003cdiv class=\"desktop-only\"\u003e\n        \u003c!--  --\u003e\n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; line-height: 26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 10px; color: black; font-family: Arial;\"\u003eDesigned for durability, this 3-way valve features multiple voltage designs, built-in limit switches, 2-wire control, and a capacitor return for efficient current and water use. Made of robust brass with NPT female thread connection, it's ideal for HVAC, water treatment, and automatic systems. The compact size allows space-efficient integration into pipelines, outperforming multiple one-way valves.\u003c\/p\u003e\n        \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/features-3%20Ways.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n             \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n    \u003ctable style=\"border-collapse: collapse;\n                  border: 0px;\n                  width: 100%;\n                  font-family: Arial;\n                  overflow-x: auto;\n                  background-color: #FFFFFF;\"\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"width: 100%;text-align: left;\n                       padding: 0px;\n                       font-size: 16px;\n                       border: 0;\n                       background-color: #FFFFFF;\"\u003e\n                \u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eSITUATION 1\u003c\/strong\u003e\u003c\/h2\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif14.gif\" style=\"width: 100%;height: 100%;\"\u003e\n            \u003c\/td\u003e\n            \u003ctd style=\"width: 100%;text-align: left;\n                       padding: 0px;\n                       font-size: 16px;\n                       border: 0;\n                       background-color: #FFFFFF;\"\u003e\n                \u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eSITUATION 2 \u003c\/strong\u003e\u003c\/h2\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif13.gif\" style=\"width: 100%;height: 100%;\"\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/table\u003e\n\u003c\/div\u003e\n \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFLOW DIRECTION ( L Type)\u003c\/strong\u003e\u003c\/p\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eSituation 1: \u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eWater enters from the bottom port. With power, it flows from the left port; without power, from the right port.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eSituation 2: \u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eWater enters from both the left and right ports. With power, it flows from the left port to the bottom; without power, from the right port to the bottom.\u003c\/p\u003e \n \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/L-type%281%29.jpg\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n          \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e \n \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV10014\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e2 Wire\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e3\/8\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eO-ring\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eFKM\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eBrass\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e0 - 5 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e110-230V AC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e5 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e3 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e2°C to 90°C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e70,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eStandard\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eActuator Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003ePPO\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e-15°C to 50°C\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eIP67\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/CE.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP67 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNO. This product can expose you to chemicals including lead, which is known to the State of California to cause cancer and birth defects or other reproductive harm.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n\u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves shown in this sheet are equipped with a manual operation function. You can manually open or close the valve safely, and this design allows for operation even in the absence of power, providing flexibility and reliability. \u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP67 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n           \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP67. The 6 in IP67 represents complete dust - tightness. The 7 in IP67 indicates protection against water immersion up to 1 meter for 30 minutes. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/IP67.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/Manual%20for%20Tonhe.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n    \u003cdiv class=\"mobile-only\"\u003e\n        \u003c!--  --\u003e\n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; line-height:26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 0px; color: black; font-family: Arial;\"\u003eDesigned for durability, this 3-way valve features multiple voltage designs, built-in limit switches, 2-wire control, and a capacitor return for efficient current and water use. Made of robust brass with NPT female thread connection, it's ideal for HVAC, water treatment, and automatic systems. The compact size allows space-efficient integration into pipelines, outperforming multiple one-way valves.\u003c\/p\u003e\n            \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/features-3%20Ways-app.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-bottom:10px; margin-top:20px; color: black;\"\u003e\u003cstrong\u003eAPPLICATION\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n    \u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eSITUATION 1\u003c\/strong\u003e\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif14.gif\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n    \u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eSITUATION 2\u003c\/strong\u003e\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif13.gif\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFLOW DIRECTION ( L Type)\u003c\/strong\u003e\u003c\/p\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eSituation 1: \u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eWater enters from the bottom port. With power, it flows from the left port; without power, from the right port.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eSituation 2: \u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eWater enters from both the left and right ports. With power, it flows from the left port to the bottom; without power, from the right port to the bottom.\u003c\/p\u003e \n \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/L-type%281%29.jpg\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n      \u003cp style=\"font-size: 16px; text-align: left; margin-bottom:10px; margin-top:20px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n         \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV10014\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e2 Wire\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e3\/8\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eO-ring\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eFKM\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eBrass\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e0 - 5 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e110-230V AC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e5 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e3 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e2°C to 90°C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e70,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eStandard\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eActuator Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003ePPO\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e-15°C to 50°C\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eIP67\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/CE.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n       \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP67 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNO. This product can expose you to chemicals including lead, which is known to the State of California to cause cancer and birth defects or other reproductive harm.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n    \u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                 \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves shown in this sheet are equipped with a manual operation function. You can manually open or close the valve safely, and this design allows for operation even in the absence of power, providing flexibility and reliability. \u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP67 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP67. The 6 in IP67 represents complete dust - tightness. The 7 in IP67 indicates protection against water immersion up to 1 meter for 30 minutes. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/IP67.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material-APP.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/Manual%20for%20Tonhe.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n    \u003cscript\u003e\n\n        \/\/ (User Agent)\n        const isMobile = window.matchMedia(\"only screen and (max-width: 600px)\").matches;\n        const desktopContent = document.querySelector('.desktop-only');\n        const mobileContent = document.querySelector('.mobile-only');\n\n        if (isMobile) {\n            \/\/ \n            console.log('');\n            \/\/ ，\n            desktopContent.style.display = 'none';\n            mobileContent.style.display = 'block';\n        } else {\n            \/\/ \n            console.log('');            \n            \/\/ ，\n            desktopContent.style.display = 'block';\n            mobileContent.style.display = 'none';\n        }\n    \u003c\/script\u003e\n\n\n\n\u003c\/body\u003e","brand":"U.S. Solid","offers":[{"title":"NPT","offer_id":46918809157887,"sku":"JFMSV10014","price":65.98,"currency_code":"USD","in_stock":true},{"title":"G","offer_id":46918809190655,"sku":"JFMSV10014-G","price":68.49,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/1__66897.1708504591.1280.1280.jpg?v=1731291567"},{"product_id":"motorized-ball-valve-ip67-1-2-stainless-steel-waterproof-full-port-110-230v-ac-2-wire-auto-return-normally-closed","title":"Motorized Ball Valve - IP67 1\/2\" Stainless Steel, Waterproof, Full Port, 110-230V AC, 2 Wire Auto Return, Normally Closed","description":"\u003cbody\u003e \n\n\n    \u003cstyle\u003e\n        @media only screen and (max-width: 600px) {\n        }\n    \u003c\/style\u003e\n\n\n    \u003cdiv class=\"desktop-only\"\u003e\n        \n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; line-height: 26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 10px; color: black; font-family: Arial;\"\u003eMotorized ball valves are a vital piece of equipment in numerous applications. This model opens and closes in 3-5 seconds, and remains in its new position while expending almost no energy. This is a key difference between motorized ball valves and many solenoid valves. Most solenoid valves are energized continuously when in a new position, while motorized ball valves expend energy only when changing from open to close, or vice versa.\u003cbr\u003eThe 2 wire auto return model is perfect for situations where the valve needs to be closed in case of power loss. The valve can be energized to open, and left hooked up, with negligible energy used once fully opened. To close, simply shutoff power to the valve. This valve is convenient because it can be operated with a simple on off switch. When on, it will remain open, when turned off (or power is lost for some other reason) the valve automatically closes.\u003c\/p\u003e\n        \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/features-JFMSV3.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n             \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n    \u003ctable style=\"border-collapse: collapse;\n                  border: 0px;\n                  width: 100%;\n                  font-family: Arial;\n                  overflow-x: auto;\n                  background-color: #FFFFFF;\"\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"width: 100%;text-align: left;\n                       padding: 0px;\n                       font-size: 16px;\n                       border: 0;\n                       background-color: #FFFFFF;\"\u003e\n                \u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 1\/2\" style=\"width: 100%;height: 100%;\"\u003e\n            \u003c\/td\u003e\n            \u003ctd style=\"width: 100%;text-align: left;\n                       padding: 0px;\n                       font-size: 16px;\n                       border: 0;\n                       background-color: #FFFFFF;\"\u003e\n                \u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 2\" style=\"width: 100%;height: 100%;\"\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/table\u003e\n\u003c\/div\u003e\n          \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e \n \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV30004\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eU.S. Solid\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1\/2\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e2 Wire Auto Return\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eSS304\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eIP67\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e3 - 5 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e110- 230V AC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e5 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e2 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e2°C to 90°C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e70,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eFull\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNormally Closed\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e-15°C to 55°C\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/CE.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP67 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYES. The motorized ball valve is made of lead-free stainless steel.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n    \u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP67 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP67. The 6 in IP67 represents complete dust - tightness. The 7 in IP67 indicates protection against water immersion up to 1 meter for 30 minutes. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/IP67-SS304.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/Manual%20for%20Tonhe.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n    \u003c\/div\u003e\n    \u003cdiv class=\"mobile-only\"\u003e\n        \n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; line-height:26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 0px; color: black; font-family: Arial;\"\u003eMotorized ball valves are a vital piece of equipment in numerous applications. This model opens and closes in 3-5 seconds, and remains in its new position while expending almost no energy. This is a key difference between motorized ball valves and many solenoid valves. Most solenoid valves are energized continuously when in a new position, while motorized ball valves expend energy only when changing from open to close, or vice versa.\u003cbr\u003eThe 2 wire auto return model is perfect for situations where the valve needs to be closed in case of power loss. The valve can be energized to open, and left hooked up, with negligible energy used once fully opened. To close, simply shutoff power to the valve. This valve is convenient because it can be operated with a simple on off switch. When on, it will remain open, when turned off (or power is lost for some other reason) the valve automatically closes.\u003c\/p\u003e\n            \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/features-JFMSV3.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-bottom:10px; margin-top:20px; color: black;\"\u003e\u003cstrong\u003eAPPLICATION\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n    \u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 1\/2\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n    \u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 2\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n\u003c\/div\u003e\n      \u003cp style=\"font-size: 16px; text-align: left; margin-bottom:10px; margin-top:20px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n       \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV30004\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eU.S. Solid\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1\/2\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e2 Wire Auto Return\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eSS304\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eIP67\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e3 - 5 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e110- 230V AC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e5 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e2 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e2°C to 90°C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e70,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eFull\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNormally Closed\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e-15°C to 55°C\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/CE.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n       \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP67 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYES. The motorized ball valve is made of lead-free stainless steel.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n    \u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                 \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP67 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP67. The 6 in IP67 represents complete dust - tightness. The 7 in IP67 indicates protection against water immersion up to 1 meter for 30 minutes. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/IP67-SS304.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material-APP.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/Manual%20for%20Tonhe.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n    \u003cscript\u003e\n\n        \n        const isMobile = window.matchMedia(\"only screen and (max-width: 600px)\").matches;\n        const desktopContent = document.querySelector('.desktop-only');\n        const mobileContent = document.querySelector('.mobile-only');\n\n        if (isMobile) {\n            \n            console.log('The user is accessing from a mobile phone or tablet device.');\n            \n            desktopContent.style.display = 'none';\n            mobileContent.style.display = 'block';\n        } else {\n           \n            console.log('The user is accessing from a desktop device.');            \n            \n            desktopContent.style.display = 'block';\n            mobileContent.style.display = 'none';\n        }\n    \u003c\/script\u003e\n\n\n\n\u003c\/body\u003e","brand":"U.S. Solid","offers":[{"title":"NPT","offer_id":46918536003839,"sku":"JFMSV30004","price":76.89,"currency_code":"USD","in_stock":true},{"title":"G","offer_id":46918536036607,"sku":"JFMSV30004-G","price":76.79,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/61bO1hFs5qL._AC_SL1500.jpg?v=1735024565"},{"product_id":"motorized-ball-valve-ip67-3-4-stainless-steel-waterproof-full-port-110-230v-ac-2-wire-auto-return","title":"Motorized Ball Valve - IP67 3\/4\" Stainless Steel, Waterproof, Full Port, 110-230V AC, 2 Wire Auto Return","description":"\u003cbody\u003e \n\n\n    \u003cstyle\u003e\n        @media only screen and (max-width: 600px) {\n        }\n    \u003c\/style\u003e\n\n\n    \u003cdiv class=\"desktop-only\"\u003e\n        \n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; line-height: 26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 10px; color: black; font-family: Arial;\"\u003eMotorized ball valves are a vital piece of equipment in numerous applications. This model opens and closes in 3-5 seconds, and remains in its new position while expending almost no energy. This is a key difference between motorized ball valves and many solenoid valves. Most solenoid valves are energized continuously when in a new position, while motorized ball valves expend energy only when changing from open to close, or vice versa.\u003cbr\u003eThe 2 wire auto return model is perfect for situations where the valve needs to be closed in case of power loss. The valve can be energized to open, and left hooked up, with negligible energy used once fully opened. To close, simply shutoff power to the valve. This valve is convenient because it can be operated with a simple on off switch. When on, it will remain open, when turned off (or power is lost for some other reason) the valve automatically closes.\u003c\/p\u003e\n        \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/features-JFMSV3.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n             \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n    \u003ctable style=\"border-collapse: collapse;\n                  border: 0px;\n                  width: 100%;\n                  font-family: Arial;\n                  overflow-x: auto;\n                  background-color: #FFFFFF;\"\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"width: 100%;text-align: left;\n                       padding: 0px;\n                       font-size: 16px;\n                       border: 0;\n                       background-color: #FFFFFF;\"\u003e\n                \u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 3\/4\" style=\"width: 100%;height: 100%;\"\u003e\n            \u003c\/td\u003e\n            \u003ctd style=\"width: 100%;text-align: left;\n                       padding: 0px;\n                       font-size: 16px;\n                       border: 0;\n                       background-color: #FFFFFF;\"\u003e\n                \u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 2\" style=\"width: 100%;height: 100%;\"\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/table\u003e\n\u003c\/div\u003e\n          \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e \n \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV30005\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eU.S. Solid\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e3\/4\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e2 Wire Auto Return\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eSS304\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eIP67\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e3 - 5 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e110- 230V AC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e5 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e2 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e2°C to 90°C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e70,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eFull\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNormally Closed\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e-15°C to 55°C\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/CE.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP67 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYES. The motorized ball valve is made of lead-free stainless steel.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n    \u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP67 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP67. The 6 in IP67 represents complete dust - tightness. The 7 in IP67 indicates protection against water immersion up to 1 meter for 30 minutes. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/IP67-SS304.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/Manual%20for%20Tonhe.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n    \u003c\/div\u003e\n    \u003cdiv class=\"mobile-only\"\u003e\n        \n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; line-height:26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 0px; color: black; font-family: Arial;\"\u003eMotorized ball valves are a vital piece of equipment in numerous applications. This model opens and closes in 3-5 seconds, and remains in its new position while expending almost no energy. This is a key difference between motorized ball valves and many solenoid valves. Most solenoid valves are energized continuously when in a new position, while motorized ball valves expend energy only when changing from open to close, or vice versa.\u003cbr\u003eThe 2 wire auto return model is perfect for situations where the valve needs to be closed in case of power loss. The valve can be energized to open, and left hooked up, with negligible energy used once fully opened. To close, simply shutoff power to the valve. This valve is convenient because it can be operated with a simple on off switch. When on, it will remain open, when turned off (or power is lost for some other reason) the valve automatically closes.\u003c\/p\u003e\n            \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/features-JFMSV3.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-bottom:10px; margin-top:20px; color: black;\"\u003e\u003cstrong\u003eAPPLICATION\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n    \u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 3\/4\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n    \u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 2\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n\u003c\/div\u003e\n      \u003cp style=\"font-size: 16px; text-align: left; margin-bottom:10px; margin-top:20px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n       \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV30005\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eU.S. Solid\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e3\/4\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e2 Wire Auto Return\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eSS304\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eIP67\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e3 - 5 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e110- 230V AC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e5 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e2 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e2°C to 90°C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e70,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eFull\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNormally Closed\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e-15°C to 55°C\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/CE.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n       \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP67 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYES. The motorized ball valve is made of lead-free stainless steel.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n    \u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                 \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP67 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP67. The 6 in IP67 represents complete dust - tightness. The 7 in IP67 indicates protection against water immersion up to 1 meter for 30 minutes. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/IP67-SS304.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material-APP.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/Manual%20for%20Tonhe.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n    \u003cscript\u003e\n\n      \n        const isMobile = window.matchMedia(\"only screen and (max-width: 600px)\").matches;\n        const desktopContent = document.querySelector('.desktop-only');\n        const mobileContent = document.querySelector('.mobile-only');\n\n        if (isMobile) {\n            \n            console.log('The user is accessing from a mobile phone or tablet device.');\n            \n            desktopContent.style.display = 'none';\n            mobileContent.style.display = 'block';\n        } else {\n           \n            console.log('The user is accessing from a desktop device.');            \n           \n            desktopContent.style.display = 'block';\n            mobileContent.style.display = 'none';\n        }\n    \u003c\/script\u003e\n\n\n\n\u003c\/body\u003e","brand":"U.S. Solid","offers":[{"title":"NPT","offer_id":46918533972223,"sku":"JFMSV30005","price":81.89,"currency_code":"USD","in_stock":true},{"title":"G","offer_id":46918534004991,"sku":"JFMSV30005-G","price":81.89,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/61KmoeAuilL._AC_SL1500.jpg?v=1735025792"},{"product_id":"motorized-ball-valve-ip67-1-stainless-steel-waterproof-full-port-110-230v-ac-2-wire-auto-return","title":"Motorized Ball Valve - IP67 1\" Stainless Steel, Waterproof, Full Port, 110-230V AC, 2 Wire Auto Return","description":"\u003cbody\u003e \n\n\n    \u003cstyle\u003e\n        @media only screen and (max-width: 600px) {\n        }\n    \u003c\/style\u003e\n\n\n    \u003cdiv class=\"desktop-only\"\u003e\n        \n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; line-height: 26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 10px; color: black; font-family: Arial;\"\u003eMotorized ball valves are a vital piece of equipment in numerous applications. This model opens and closes in 3-5 seconds, and remains in its new position while expending almost no energy. This is a key difference between motorized ball valves and many solenoid valves. Most solenoid valves are energized continuously when in a new position, while motorized ball valves expend energy only when changing from open to close, or vice versa.\u003cbr\u003eThe 2 wire auto return model is perfect for situations where the valve needs to be closed in case of power loss. The valve can be energized to open, and left hooked up, with negligible energy used once fully opened. To close, simply shutoff power to the valve. This valve is convenient because it can be operated with a simple on off switch. When on, it will remain open, when turned off (or power is lost for some other reason) the valve automatically closes.\u003c\/p\u003e\n        \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/features-JFMSV3.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n             \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n    \u003ctable style=\"border-collapse: collapse;\n                  border: 0px;\n                  width: 100%;\n                  font-family: Arial;\n                  overflow-x: auto;\n                  background-color: #FFFFFF;\"\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"width: 100%;text-align: left;\n                       padding: 0px;\n                       font-size: 16px;\n                       border: 0;\n                       background-color: #FFFFFF;\"\u003e\n                \u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 1\" style=\"width: 100%;height: 100%;\"\u003e\n            \u003c\/td\u003e\n            \u003ctd style=\"width: 100%;text-align: left;\n                       padding: 0px;\n                       font-size: 16px;\n                       border: 0;\n                       background-color: #FFFFFF;\"\u003e\n                \u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 2\" style=\"width: 100%;height: 100%;\"\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/table\u003e\n\u003c\/div\u003e\n          \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e \n \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV30006\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eU.S. Solid\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e2 Wire Auto Return\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eSS304\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eIP67\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e3 - 5 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e110- 230V AC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e5 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e2 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e2°C to 90°C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e70,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eFull\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNormally Closed\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e-15°C to 55°C\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/CE.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP67 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYES. The motorized ball valve is made of lead-free stainless steel.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n    \u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP67 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP67. The 6 in IP67 represents complete dust - tightness. The 7 in IP67 indicates protection against water immersion up to 1 meter for 30 minutes. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/IP67-SS304.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/Manual%20for%20Tonhe.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n    \u003c\/div\u003e\n    \u003cdiv class=\"mobile-only\"\u003e\n    \n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; line-height:26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 0px; color: black; font-family: Arial;\"\u003eMotorized ball valves are a vital piece of equipment in numerous applications. This model opens and closes in 3-5 seconds, and remains in its new position while expending almost no energy. This is a key difference between motorized ball valves and many solenoid valves. Most solenoid valves are energized continuously when in a new position, while motorized ball valves expend energy only when changing from open to close, or vice versa.\u003cbr\u003eThe 2 wire auto return model is perfect for situations where the valve needs to be closed in case of power loss. The valve can be energized to open, and left hooked up, with negligible energy used once fully opened. To close, simply shutoff power to the valve. This valve is convenient because it can be operated with a simple on off switch. When on, it will remain open, when turned off (or power is lost for some other reason) the valve automatically closes.\u003c\/p\u003e\n            \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/features-JFMSV3.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-bottom:10px; margin-top:20px; color: black;\"\u003e\u003cstrong\u003eAPPLICATION\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n    \u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 1\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n    \u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 2\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n\u003c\/div\u003e\n      \u003cp style=\"font-size: 16px; text-align: left; margin-bottom:10px; margin-top:20px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n       \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV30006\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eU.S. Solid\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e2 Wire Auto Return\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eSS304\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eIP67\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e3 - 5 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e110- 230V AC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e5 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e2 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e2°C to 90°C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e70,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eFull\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNormally Closed\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e-15°C to 55°C\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/CE.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n       \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP67 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYES. The motorized ball valve is made of lead-free stainless steel.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n    \u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                 \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP67 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP67. The 6 in IP67 represents complete dust - tightness. The 7 in IP67 indicates protection against water immersion up to 1 meter for 30 minutes. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/IP67-SS304.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material-APP.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/Manual%20for%20Tonhe.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n    \u003cscript\u003e\n\n        \n        const isMobile = window.matchMedia(\"only screen and (max-width: 600px)\").matches;\n        const desktopContent = document.querySelector('.desktop-only');\n        const mobileContent = document.querySelector('.mobile-only');\n\n        if (isMobile) {\n           \n            console.log('The user is accessing from a mobile phone or tablet device.');\n            \n            desktopContent.style.display = 'none';\n            mobileContent.style.display = 'block';\n        } else {\n            \n            console.log('The user is accessing from a desktop device.');            \n            \n            desktopContent.style.display = 'block';\n            mobileContent.style.display = 'none';\n        }\n    \u003c\/script\u003e\n\n\n\n\u003c\/body\u003e","brand":"U.S. Solid","offers":[{"title":"NPT","offer_id":46918531219711,"sku":"JFMSV30006","price":90.11,"currency_code":"USD","in_stock":true},{"title":"G","offer_id":46918531252479,"sku":"JFMSV30006-G","price":87.39,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/61bO1hFs5qL._AC_SL1500_a604d395-3060-4c20-b4e5-f159b6f6d8a2.jpg?v=1735025723"},{"product_id":"motorized-ball-valve-ip67-1-2-brass-waterproof-full-port-110-230v-ac-2-wire-auto-return","title":"Motorized Ball Valve - IP67 1\/2\" Brass, Waterproof, Full Port, 110-230V AC, 2 Wire Auto Return","description":"\u003cbody\u003e \n\n\n    \u003cstyle\u003e\n        @media only screen and (max-width: 600px) {\n        }\n    \u003c\/style\u003e\n\n\n    \u003cdiv class=\"desktop-only\"\u003e\n        \n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; line-height: 26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 10px; color: black; font-family: Arial;\"\u003eMotorized ball valves are a vital piece of equipment in numerous applications. This model opens and closes in 3-5 seconds, and remains in its new position while expending almost no energy. This is a key difference between motorized ball valves and many solenoid valves. Most solenoid valves are energized continuously when in a new position, while motorized ball valves expend energy only when changing from open to close, or vice versa.\u003cbr\u003eThe 2 wire auto return model is perfect for situations where the valve needs to be closed in case of power loss. The valve can be energized to open, and left hooked up, with negligible energy used once fully opened. To close, simply shutoff power to the valve. This valve is convenient because it can be operated with a simple on off switch. When on, it will remain open, when turned off (or power is lost for some other reason) the valve automatically closes.\u003c\/p\u003e\n        \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/features-JFMSV3.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n             \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n    \u003ctable style=\"border-collapse: collapse;\n                  border: 0px;\n                  width: 100%;\n                  font-family: Arial;\n                  overflow-x: auto;\n                  background-color: #FFFFFF;\"\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"width: 100%;text-align: left;\n                       padding: 0px;\n                       font-size: 16px;\n                       border: 0;\n                       background-color: #FFFFFF;\"\u003e\n                \u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 1\" style=\"width: 100%;height: 100%;\"\u003e\n            \u003c\/td\u003e\n            \u003ctd style=\"width: 100%;text-align: left;\n                       padding: 0px;\n                       font-size: 16px;\n                       border: 0;\n                       background-color: #FFFFFF;\"\u003e\n                \u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 2\" style=\"width: 100%;height: 100%;\"\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/table\u003e\n\u003c\/div\u003e\n          \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e \n \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV30010\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eU.S. Solid\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1\/2\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e2 Wire Auto Return\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eBrass\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eIP67\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e3 - 5 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e110- 230V AC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e5 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e2 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e2°C to 90°C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e70,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eFull\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNormally Closed\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e-15°C to 55°C\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/CE.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP67 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNO. This motorized ball valve is made of brass, which contains lead, should not be used for drinking water.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n    \u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP67 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP67. The 6 in IP67 represents complete dust - tightness. The 7 in IP67 indicates protection against water immersion up to 1 meter for 30 minutes. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/IP67.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/Manual%20for%20Tonhe.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n    \u003c\/div\u003e\n    \u003cdiv class=\"mobile-only\"\u003e\n      \n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; line-height:26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 0px; color: black; font-family: Arial;\"\u003eMotorized ball valves are a vital piece of equipment in numerous applications. This model opens and closes in 3-5 seconds, and remains in its new position while expending almost no energy. This is a key difference between motorized ball valves and many solenoid valves. Most solenoid valves are energized continuously when in a new position, while motorized ball valves expend energy only when changing from open to close, or vice versa.\u003cbr\u003eThe 2 wire auto return model is perfect for situations where the valve needs to be closed in case of power loss. The valve can be energized to open, and left hooked up, with negligible energy used once fully opened. To close, simply shutoff power to the valve. This valve is convenient because it can be operated with a simple on off switch. When on, it will remain open, when turned off (or power is lost for some other reason) the valve automatically closes.\u003c\/p\u003e\n            \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/features-JFMSV3.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-bottom:10px; margin-top:20px; color: black;\"\u003e\u003cstrong\u003eAPPLICATION\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n    \u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 1\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n    \u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 2\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n\u003c\/div\u003e\n      \u003cp style=\"font-size: 16px; text-align: left; margin-bottom:10px; margin-top:20px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n       \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV30010\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eU.S. Solid\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1\/2\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e2 Wire Auto Return\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eBrass\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e3 - 5 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e110- 230V AC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e5 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e2 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e2°C to 90°C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e70,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eFull\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNormally Closed\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e-15°C to 55°C\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eIP67\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/CE.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n       \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP67 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNO. This motorized ball valve is made of brass, which contains lead, should not be used for drinking water.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n    \u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                 \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP67 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP67. The 6 in IP67 represents complete dust - tightness. The 7 in IP67 indicates protection against water immersion up to 1 meter for 30 minutes. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/IP67.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material-APP.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/Manual%20for%20Tonhe.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n    \u003cscript\u003e\n\n      \n        const isMobile = window.matchMedia(\"only screen and (max-width: 600px)\").matches;\n        const desktopContent = document.querySelector('.desktop-only');\n        const mobileContent = document.querySelector('.mobile-only');\n\n        if (isMobile) {\n            \n            console.log('The user is accessing from a mobile phone or tablet device.');\n            \n            desktopContent.style.display = 'none';\n            mobileContent.style.display = 'block';\n        } else {\n            \n            console.log('The user is accessing from a desktop device.');            \n           \n            desktopContent.style.display = 'block';\n            mobileContent.style.display = 'none';\n        }\n    \u003c\/script\u003e\n\n\n\n\u003c\/body\u003e","brand":"U.S. Solid","offers":[{"title":"NPT","offer_id":46918517129471,"sku":"JFMSV30010","price":67.99,"currency_code":"USD","in_stock":true},{"title":"G","offer_id":46918517162239,"sku":"JFMSV30010-G","price":68.69,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/61KmoeAuilL._AC_SL1500_bb64771d-07b5-4a45-b6e8-4170cd6be606.jpg?v=1735027805"},{"product_id":"motorized-ball-valve-ip67-3-4-brass-waterproof-full-port-110-230v-ac-2-wire-auto-return","title":"Motorized Ball Valve - IP67 3\/4\" Brass, Waterproof, Full Port, 110-230V AC, 2 Wire Auto Return","description":"\u003cbody\u003e \n\n\n    \u003cstyle\u003e\n        @media only screen and (max-width: 600px) {\n        }\n    \u003c\/style\u003e\n\n\n    \u003cdiv class=\"desktop-only\"\u003e\n        \n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; line-height: 26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 10px; color: black; font-family: Arial;\"\u003eMotorized ball valves are a vital piece of equipment in numerous applications. This model opens and closes in 3-5 seconds, and remains in its new position while expending almost no energy. This is a key difference between motorized ball valves and many solenoid valves. Most solenoid valves are energized continuously when in a new position, while motorized ball valves expend energy only when changing from open to close, or vice versa.\u003cbr\u003eThe 2 wire auto return model is perfect for situations where the valve needs to be closed in case of power loss. The valve can be energized to open, and left hooked up, with negligible energy used once fully opened. To close, simply shutoff power to the valve. This valve is convenient because it can be operated with a simple on off switch. When on, it will remain open, when turned off (or power is lost for some other reason) the valve automatically closes.\u003c\/p\u003e\n        \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/features-JFMSV3.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n             \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n    \u003ctable style=\"border-collapse: collapse;\n                  border: 0px;\n                  width: 100%;\n                  font-family: Arial;\n                  overflow-x: auto;\n                  background-color: #FFFFFF;\"\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"width: 100%;text-align: left;\n                       padding: 0px;\n                       font-size: 16px;\n                       border: 0;\n                       background-color: #FFFFFF;\"\u003e\n                \u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 1\" style=\"width: 100%;height: 100%;\"\u003e\n            \u003c\/td\u003e\n            \u003ctd style=\"width: 100%;text-align: left;\n                       padding: 0px;\n                       font-size: 16px;\n                       border: 0;\n                       background-color: #FFFFFF;\"\u003e\n                \u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 2\" style=\"width: 100%;height: 100%;\"\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/table\u003e\n\u003c\/div\u003e\n          \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e \n \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV30011\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eU.S. Solid\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e3\/4\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e2 Wire Auto Return\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eBrass\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eIP67\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e3 - 5 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e110- 230V AC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e5 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e2 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e2°C to 90°C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e70,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eFull\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNormally Closed\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e-15°C to 55°C\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/CE.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP67 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNO. This motorized ball valve is made of brass, which contains lead, should not be used for drinking water.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n    \u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP67 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP67. The 6 in IP67 represents complete dust - tightness. The 7 in IP67 indicates protection against water immersion up to 1 meter for 30 minutes. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/IP67.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/Manual%20for%20Tonhe.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n    \u003c\/div\u003e\n    \u003cdiv class=\"mobile-only\"\u003e\n        \n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; line-height:26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 0px; color: black; font-family: Arial;\"\u003eMotorized ball valves are a vital piece of equipment in numerous applications. This model opens and closes in 3-5 seconds, and remains in its new position while expending almost no energy. This is a key difference between motorized ball valves and many solenoid valves. Most solenoid valves are energized continuously when in a new position, while motorized ball valves expend energy only when changing from open to close, or vice versa.\u003cbr\u003eThe 2 wire auto return model is perfect for situations where the valve needs to be closed in case of power loss. The valve can be energized to open, and left hooked up, with negligible energy used once fully opened. To close, simply shutoff power to the valve. This valve is convenient because it can be operated with a simple on off switch. When on, it will remain open, when turned off (or power is lost for some other reason) the valve automatically closes.\u003c\/p\u003e\n            \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/features-JFMSV3.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-bottom:10px; margin-top:20px; color: black;\"\u003e\u003cstrong\u003eAPPLICATION\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n    \u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 1\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n    \u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 2\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n\u003c\/div\u003e\n      \u003cp style=\"font-size: 16px; text-align: left; margin-bottom:10px; margin-top:20px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n       \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV30011\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eU.S. Solid\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e3\/4\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e2 Wire Auto Return\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eBrass\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eIP67\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e3 - 5 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e110- 230V AC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e5 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e2 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e2°C to 90°C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e70,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eFull\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNormally Closed\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e-15°C to 55°C\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/CE.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n       \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP67 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNO. This motorized ball valve is made of brass, which contains lead, should not be used for drinking water.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n    \u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                 \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP67 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP67. The 6 in IP67 represents complete dust - tightness. The 7 in IP67 indicates protection against water immersion up to 1 meter for 30 minutes. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/IP67.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material-APP.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/Manual%20for%20Tonhe.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n    \u003cscript\u003e\n\n       \n        const isMobile = window.matchMedia(\"only screen and (max-width: 600px)\").matches;\n        const desktopContent = document.querySelector('.desktop-only');\n        const mobileContent = document.querySelector('.mobile-only');\n\n        if (isMobile) {\n            \n            console.log('The user is accessing from a mobile phone or tablet device.');\n      \n            desktopContent.style.display = 'none';\n            mobileContent.style.display = 'block';\n        } else {\n           \n            console.log('The user is accessing from a desktop device.');            \n           \n            desktopContent.style.display = 'block';\n            mobileContent.style.display = 'none';\n        }\n    \u003c\/script\u003e\n\n\n\n\u003c\/body\u003e","brand":"U.S. Solid","offers":[{"title":"NPT","offer_id":46918509330687,"sku":"JFMSV30011","price":77.89,"currency_code":"USD","in_stock":true},{"title":"G","offer_id":46918509363455,"sku":"JFMSV30011-G","price":75.79,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/61KmoeAuilL._AC_SL1500_b4bec68b-2fb8-4cef-b371-0af8bcb43c21.jpg?v=1735027939"},{"product_id":"motorized-ball-valve-ip67-1-brass-waterproof-full-port-110-230v-ac-2-wire-auto-return","title":"Motorized Ball Valve - IP67 1\" Brass, Waterproof, Full Port, 110-230V AC, 2 Wire Auto Return","description":"\u003cbody\u003e \n\n\n    \u003cstyle\u003e\n        @media only screen and (max-width: 600px) {\n        }\n    \u003c\/style\u003e\n\n\n    \u003cdiv class=\"desktop-only\"\u003e\n        \n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; line-height: 26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 10px; color: black; font-family: Arial;\"\u003eMotorized ball valves are a vital piece of equipment in numerous applications. This model opens and closes in 3-5 seconds, and remains in its new position while expending almost no energy. This is a key difference between motorized ball valves and many solenoid valves. Most solenoid valves are energized continuously when in a new position, while motorized ball valves expend energy only when changing from open to close, or vice versa.\u003cbr\u003eThe 2 wire auto return model is perfect for situations where the valve needs to be closed in case of power loss. The valve can be energized to open, and left hooked up, with negligible energy used once fully opened. To close, simply shutoff power to the valve. This valve is convenient because it can be operated with a simple on off switch. When on, it will remain open, when turned off (or power is lost for some other reason) the valve automatically closes.\u003c\/p\u003e\n        \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/features-JFMSV3.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n             \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n    \u003ctable style=\"border-collapse: collapse;\n                  border: 0px;\n                  width: 100%;\n                  font-family: Arial;\n                  overflow-x: auto;\n                  background-color: #FFFFFF;\"\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"width: 100%;text-align: left;\n                       padding: 0px;\n                       font-size: 16px;\n                       border: 0;\n                       background-color: #FFFFFF;\"\u003e\n                \u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 1\" style=\"width: 100%;height: 100%;\"\u003e\n            \u003c\/td\u003e\n            \u003ctd style=\"width: 100%;text-align: left;\n                       padding: 0px;\n                       font-size: 16px;\n                       border: 0;\n                       background-color: #FFFFFF;\"\u003e\n                \u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 2\" style=\"width: 100%;height: 100%;\"\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/table\u003e\n\u003c\/div\u003e\n          \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e \n \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV30012\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eU.S. Solid\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e2 Wire Auto Return\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eBrass\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eIP67\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e3 - 5 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e110- 230V AC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e5 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e2 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e2°C to 90°C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e70,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eFull\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNormally Closed\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e-15°C to 55°C\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/CE.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP67 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNO. This motorized ball valve is made of brass, which contains lead, should not be used for drinking water.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n    \u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP67 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP67. The 6 in IP67 represents complete dust - tightness. The 7 in IP67 indicates protection against water immersion up to 1 meter for 30 minutes. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/IP67.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/Manual%20for%20Tonhe.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n    \u003c\/div\u003e\n    \u003cdiv class=\"mobile-only\"\u003e\n        \n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; line-height:26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 0px; color: black; font-family: Arial;\"\u003eMotorized ball valves are a vital piece of equipment in numerous applications. This model opens and closes in 3-5 seconds, and remains in its new position while expending almost no energy. This is a key difference between motorized ball valves and many solenoid valves. Most solenoid valves are energized continuously when in a new position, while motorized ball valves expend energy only when changing from open to close, or vice versa.\u003cbr\u003eThe 2 wire auto return model is perfect for situations where the valve needs to be closed in case of power loss. The valve can be energized to open, and left hooked up, with negligible energy used once fully opened. To close, simply shutoff power to the valve. This valve is convenient because it can be operated with a simple on off switch. When on, it will remain open, when turned off (or power is lost for some other reason) the valve automatically closes.\u003c\/p\u003e\n            \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/features-JFMSV3.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-bottom:10px; margin-top:20px; color: black;\"\u003e\u003cstrong\u003eAPPLICATION\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n    \u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 1\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n    \u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 2\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n\u003c\/div\u003e\n      \u003cp style=\"font-size: 16px; text-align: left; margin-bottom:10px; margin-top:20px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n       \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV30012\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eU.S. Solid\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e2 Wire Auto Return\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eBrass\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eIP67\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e3 - 5 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e110- 230V AC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e5 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e2 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e2°C to 90°C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e70,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eFull\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNormally Closed\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e-15°C to 55°C\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/CE.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n       \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP67 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNO. This motorized ball valve is made of brass, which contains lead, should not be used for drinking water.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n    \u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                 \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP67 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP67. The 6 in IP67 represents complete dust - tightness. The 7 in IP67 indicates protection against water immersion up to 1 meter for 30 minutes. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/IP67.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material-APP.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/Manual%20for%20Tonhe.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n    \u003cscript\u003e\n\n     \n        const isMobile = window.matchMedia(\"only screen and (max-width: 600px)\").matches;\n        const desktopContent = document.querySelector('.desktop-only');\n        const mobileContent = document.querySelector('.mobile-only');\n\n        if (isMobile) {\n          \n            console.log('The user is accessing from a mobile phone or tablet device.');\n           \n            desktopContent.style.display = 'none';\n            mobileContent.style.display = 'block';\n        } else {\n           \n            console.log('The user is accessing from a desktop device.');            \n            \n            desktopContent.style.display = 'block';\n            mobileContent.style.display = 'none';\n        }\n    \u003c\/script\u003e\n\n\n\n\u003c\/body\u003e","brand":"U.S. Solid","offers":[{"title":"NPT","offer_id":46918505922815,"sku":"JFMSV30012","price":77.59,"currency_code":"USD","in_stock":true},{"title":"G","offer_id":46918505955583,"sku":"JFMSV30012-G","price":80.79,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/61KmoeAuilL._AC_SL1500_32eb4288-9069-4bcc-869a-1a87d54114c4.jpg?v=1735028315"},{"product_id":"12-3-way-ss304-motorized-ball-valve-2-wire-ac110-230v-t-type-standard-port-with-manual-function-ip67","title":"1\/2\" 3 Way SS304 Motorized Ball Valve,  2 Wire, AC110-230V,  T Type,  Standard Port with Manual Function,  IP67","description":"\u003cbody\u003e \n\n\n    \u003cstyle\u003e\n        @media only screen and (max-width: 600px) {\n        }\n    \u003c\/style\u003e\n\n\n    \u003cdiv class=\"desktop-only\"\u003e\n        \u003c!--  --\u003e\n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; line-height: 26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 10px; color: black; font-family: Arial;\"\u003eDesigned for durability, this 3-way valve features multiple voltage designs, built-in limit switches, 2-wire control, and a capacitor return for efficient current and water use. Made of robust stainless steel with NPT female thread connection, it's ideal for HVAC, water treatment, and automatic systems. The compact size allows space-efficient integration into pipelines, outperforming multiple one-way valves.\u003c\/p\u003e\n        \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/features-3%20Ways.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFLOW DIRECTION ( T Type)\u003c\/strong\u003e\u003c\/p\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eSituation 1: \u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eWith power, water flows from the LEFT port to the RIGHT port. Without power, water flows from the LEFT port to the BOTTOM port.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eSituation 2: \u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eWith power, water flows from the RIGHT to the LEFT port. Without power, water flows from the BOTTOM to the LEFT port.\u003c\/p\u003e \n \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/T-type%281%29.jpg\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n          \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e \n \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV10026\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e2 Wire\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1\/2\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eO-ring\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eFKM\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eSS304\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e0 - 5 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e110-230V AC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e5 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e3 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e2°C to 90°C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e70,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eStandard\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eActuator Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003ePPO\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e-15°C to 50°C\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eIP67\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/CE.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP67 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYES. The motorized ball valve is made of lead-free stainless steel.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n\u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves shown in this sheet are equipped with a manual operation function. You can manually open or close the valve safely, and this design allows for operation even in the absence of power, providing flexibility and reliability. \u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP67 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n           \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP67. The 6 in IP67 represents complete dust - tightness. The 7 in IP67 indicates protection against water immersion up to 1 meter for 30 minutes. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/IP67-SS304.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/Manual%20for%20Tonhe.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n    \u003cdiv class=\"mobile-only\"\u003e\n        \u003c!--  --\u003e\n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; line-height:26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 0px; color: black; font-family: Arial;\"\u003eDesigned for durability, this 3-way valve features multiple voltage designs, built-in limit switches, 2-wire control, and a capacitor return for efficient current and water use. Made of robust stainless steel with NPT female thread connection, it's ideal for HVAC, water treatment, and automatic systems. The compact size allows space-efficient integration into pipelines, outperforming multiple one-way valves.\u003c\/p\u003e\n            \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/features-3%20Ways-app.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-bottom:10px; margin-top:20px; color: black;\"\u003e\u003cstrong\u003eAPPLICATION\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFLOW DIRECTION ( T Type)\u003c\/strong\u003e\u003c\/p\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eSituation 1: \u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eWith power, water flows from the LEFT port to the RIGHT port. Without power, water flows from the LEFT port to the BOTTOM port.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eSituation 2: \u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eWith power, water flows from the RIGHT to the LEFT port. Without power, water flows from the BOTTOM to the LEFT port.\u003c\/p\u003e \n \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/T-type%281%29.jpg\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n      \u003cp style=\"font-size: 16px; text-align: left; margin-bottom:10px; margin-top:20px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n         \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV10026\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e2 Wire\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1\/2\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eO-ring\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eFKM\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eSS304\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e0 - 5 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e110-230V AC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e5 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e3 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e2°C to 90°C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e70,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eStandard\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eActuator Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003ePPO\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e-15°C to 50°C\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eIP67\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/CE.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n       \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP67 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYES. The motorized ball valve is made of lead-free stainless steel.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n    \u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                 \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves shown in this sheet are equipped with a manual operation function. You can manually open or close the valve safely, and this design allows for operation even in the absence of power, providing flexibility and reliability. \u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP67 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP67. The 6 in IP67 represents complete dust - tightness. The 7 in IP67 indicates protection against water immersion up to 1 meter for 30 minutes. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/IP67-SS304.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material-APP.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/Manual%20for%20Tonhe.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n    \u003cscript\u003e\n\n        \/\/ (User Agent)\n        const isMobile = window.matchMedia(\"only screen and (max-width: 600px)\").matches;\n        const desktopContent = document.querySelector('.desktop-only');\n        const mobileContent = document.querySelector('.mobile-only');\n\n        if (isMobile) {\n            \/\/ \n            console.log('');\n            \/\/ ，\n            desktopContent.style.display = 'none';\n            mobileContent.style.display = 'block';\n        } else {\n            \/\/ \n            console.log('');            \n            \/\/ ，\n            desktopContent.style.display = 'block';\n            mobileContent.style.display = 'none';\n        }\n    \u003c\/script\u003e\n\n\n\n\u003c\/body\u003e","brand":"U.S. Solid","offers":[{"title":"NPT","offer_id":46918472302847,"sku":"JFMSV10026","price":101.99,"currency_code":"USD","in_stock":true},{"title":"G","offer_id":46918472335615,"sku":"JFMSV10026-G","price":101.99,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/71OjmILKFTL._AC_SL1500.jpg?v=1740647643"},{"product_id":"34-3-way-ss304-motorized-ball-valve-2-wire-ac110-230v-t-type-standard-port-with-manual-function-ip67","title":"3\/4\" 3 Way SS304 Motorized Ball Valve,  2 Wire, AC110-230V,  T Type,  Standard Port with Manual Function,  IP67","description":"\u003cbody\u003e \n\n\n    \u003cstyle\u003e\n        @media only screen and (max-width: 600px) {\n        }\n    \u003c\/style\u003e\n\n\n    \u003cdiv class=\"desktop-only\"\u003e\n        \u003c!--  --\u003e\n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; line-height: 26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 10px; color: black; font-family: Arial;\"\u003eDesigned for durability, this 3-way valve features multiple voltage designs, built-in limit switches, 2-wire control, and a capacitor return for efficient current and water use. Made of robust stainless steel with NPT female thread connection, it's ideal for HVAC, water treatment, and automatic systems. The compact size allows space-efficient integration into pipelines, outperforming multiple one-way valves.\u003c\/p\u003e\n        \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/features-3%20Ways.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFLOW DIRECTION ( T Type)\u003c\/strong\u003e\u003c\/p\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eSituation 1: \u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eWith power, water flows from the LEFT port to the RIGHT port. Without power, water flows from the LEFT port to the BOTTOM port.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eSituation 2: \u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eWith power, water flows from the RIGHT to the LEFT port. Without power, water flows from the BOTTOM to the LEFT port.\u003c\/p\u003e \n \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/T-type%281%29.jpg\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n          \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e \n \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV10027\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e2 Wire\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e3\/4\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eO-ring\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eFKM\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eSS304\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e0 - 5 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e110-230V AC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e5 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e3 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e2°C to 90°C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e70,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eStandard\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eActuator Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003ePPO\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e-15°C to 50°C\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eIP67\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/CE.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP67 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYES. The motorized ball valve is made of lead-free stainless steel.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n\u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves shown in this sheet are equipped with a manual operation function. You can manually open or close the valve safely, and this design allows for operation even in the absence of power, providing flexibility and reliability. \u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP67 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n           \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP67. The 6 in IP67 represents complete dust - tightness. The 7 in IP67 indicates protection against water immersion up to 1 meter for 30 minutes. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/IP67-SS304.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/Manual%20for%20Tonhe.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n    \u003cdiv class=\"mobile-only\"\u003e\n        \u003c!--  --\u003e\n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; line-height:26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 0px; color: black; font-family: Arial;\"\u003eDesigned for durability, this 3-way valve features multiple voltage designs, built-in limit switches, 2-wire control, and a capacitor return for efficient current and water use. Made of robust stainless steel with NPT female thread connection, it's ideal for HVAC, water treatment, and automatic systems. The compact size allows space-efficient integration into pipelines, outperforming multiple one-way valves.\u003c\/p\u003e\n            \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/features-3%20Ways-app.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-bottom:10px; margin-top:20px; color: black;\"\u003e\u003cstrong\u003eAPPLICATION\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFLOW DIRECTION ( T Type)\u003c\/strong\u003e\u003c\/p\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eSituation 1: \u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eWith power, water flows from the LEFT port to the RIGHT port. Without power, water flows from the LEFT port to the BOTTOM port.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eSituation 2: \u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eWith power, water flows from the RIGHT to the LEFT port. Without power, water flows from the BOTTOM to the LEFT port.\u003c\/p\u003e \n \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/T-type%281%29.jpg\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n      \u003cp style=\"font-size: 16px; text-align: left; margin-bottom:10px; margin-top:20px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n         \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV10027\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e2 Wire\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e3\/4\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eO-ring\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eFKM\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eSS304\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e0 - 5 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e110-230V AC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e5 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e3 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e2°C to 90°C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e70,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eStandard\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eActuator Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003ePPO\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e-15°C to 50°C\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eIP67\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/CE.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n       \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP67 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYES. The motorized ball valve is made of lead-free stainless steel.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n    \u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                 \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves shown in this sheet are equipped with a manual operation function. You can manually open or close the valve safely, and this design allows for operation even in the absence of power, providing flexibility and reliability. \u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP67 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP67. The 6 in IP67 represents complete dust - tightness. The 7 in IP67 indicates protection against water immersion up to 1 meter for 30 minutes. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/IP67-SS304.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material-APP.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/Manual%20for%20Tonhe.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n    \u003cscript\u003e\n\n        \/\/ (User Agent)\n        const isMobile = window.matchMedia(\"only screen and (max-width: 600px)\").matches;\n        const desktopContent = document.querySelector('.desktop-only');\n        const mobileContent = document.querySelector('.mobile-only');\n\n        if (isMobile) {\n            \/\/ \n            console.log('');\n            \/\/ ，\n            desktopContent.style.display = 'none';\n            mobileContent.style.display = 'block';\n        } else {\n            \/\/ \n            console.log('');            \n            \/\/ ，\n            desktopContent.style.display = 'block';\n            mobileContent.style.display = 'none';\n        }\n    \u003c\/script\u003e\n\n\n\n\u003c\/body\u003e","brand":"U.S. Solid","offers":[{"title":"NPT","offer_id":46918470402303,"sku":"JFMSV10027","price":105.99,"currency_code":"USD","in_stock":true},{"title":"G","offer_id":46918470435071,"sku":"JFMSV10027-G","price":105.99,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/71fYp5-NzjL._AC_SL1500.jpg?v=1740648130"},{"product_id":"1-3-way-ss304-motorized-ball-valve-2-wire-ac110-230v-t-type-standard-port-with-manual-function-ip67","title":"1\" 3 Way SS304 Motorized Ball Valve,  2 Wire, AC110-230V,  T Type,  Standard Port with Manual Function,  IP67","description":"\u003cbody\u003e \n\n\n    \u003cstyle\u003e\n        @media only screen and (max-width: 600px) {\n        }\n    \u003c\/style\u003e\n\n\n    \u003cdiv class=\"desktop-only\"\u003e\n        \n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; line-height: 26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 10px; color: black; font-family: Arial;\"\u003eDesigned for durability, this 3-way valve features multiple voltage designs, built-in limit switches, 2-wire control, and a capacitor return for efficient current and water use. Made of robust stainless steel with NPT female thread connection, it's ideal for HVAC, water treatment, and automatic systems. The compact size allows space-efficient integration into pipelines, outperforming multiple one-way valves.\u003c\/p\u003e\n        \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/features-3%20Ways.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFLOW DIRECTION ( T Type)\u003c\/strong\u003e\u003c\/p\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eSituation 1: \u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eWith power, water flows from the LEFT port to the RIGHT port. Without power, water flows from the LEFT port to the BOTTOM port.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eSituation 2: \u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eWith power, water flows from the RIGHT to the LEFT port. Without power, water flows from the BOTTOM to the LEFT port.\u003c\/p\u003e \n \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/T-type%281%29.jpg\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n          \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e \n \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV10028\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e2 Wire\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eO-ring\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eFKM\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eSS304\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e0 - 5 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e110-230V AC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e5 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e3 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e2°C to 90°C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e70,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eStandard\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eActuator Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003ePPO\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e-15°C to 50°C\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eIP67\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/CE.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP67 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYES. The motorized ball valve is made of lead-free stainless steel.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n\u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves shown in this sheet are equipped with a manual operation function. You can manually open or close the valve safely, and this design allows for operation even in the absence of power, providing flexibility and reliability. \u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP67 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n           \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP67. The 6 in IP67 represents complete dust - tightness. The 7 in IP67 indicates protection against water immersion up to 1 meter for 30 minutes. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/IP67-SS304.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/Manual%20for%20Tonhe.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n    \u003cdiv class=\"mobile-only\"\u003e\n        \n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; line-height:26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 0px; color: black; font-family: Arial;\"\u003eDesigned for durability, this 3-way valve features multiple voltage designs, built-in limit switches, 2-wire control, and a capacitor return for efficient current and water use. Made of robust stainless steel with NPT female thread connection, it's ideal for HVAC, water treatment, and automatic systems. The compact size allows space-efficient integration into pipelines, outperforming multiple one-way valves.\u003c\/p\u003e\n            \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/features-3%20Ways-app.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-bottom:10px; margin-top:20px; color: black;\"\u003e\u003cstrong\u003eAPPLICATION\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFLOW DIRECTION ( T Type)\u003c\/strong\u003e\u003c\/p\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eSituation 1: \u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eWith power, water flows from the LEFT port to the RIGHT port. Without power, water flows from the LEFT port to the BOTTOM port.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eSituation 2: \u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eWith power, water flows from the RIGHT to the LEFT port. Without power, water flows from the BOTTOM to the LEFT port.\u003c\/p\u003e \n \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/T-type%281%29.jpg\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n      \u003cp style=\"font-size: 16px; text-align: left; margin-bottom:10px; margin-top:20px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n         \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV10028\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e2 Wire\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eO-ring\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eFKM\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eSS304\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e0 - 5 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e110-230V AC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e5 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e3 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e2°C to 90°C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e70,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eStandard\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eActuator Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003ePPO\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e-15°C to 50°C\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eIP67\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/CE.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n       \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP67 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYES. The motorized ball valve is made of lead-free stainless steel.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n    \u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                 \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves shown in this sheet are equipped with a manual operation function. You can manually open or close the valve safely, and this design allows for operation even in the absence of power, providing flexibility and reliability. \u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP67 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP67. The 6 in IP67 represents complete dust - tightness. The 7 in IP67 indicates protection against water immersion up to 1 meter for 30 minutes. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/IP67-SS304.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material-APP.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/Manual%20for%20Tonhe.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n    \u003cscript\u003e\n\n        \/\/ (User Agent)\n        const isMobile = window.matchMedia(\"only screen and (max-width: 600px)\").matches;\n        const desktopContent = document.querySelector('.desktop-only');\n        const mobileContent = document.querySelector('.mobile-only');\n\n        if (isMobile) {\n            \/\/ \n            console.log('');\n            \/\/ ，\n            desktopContent.style.display = 'none';\n            mobileContent.style.display = 'block';\n        } else {\n            \/\/ \n            console.log('');            \n            \/\/ ，\n            desktopContent.style.display = 'block';\n            mobileContent.style.display = 'none';\n        }\n    \u003c\/script\u003e\n\n\n\n\u003c\/body\u003e","brand":"U.S. Solid","offers":[{"title":"NPT","offer_id":46918469026047,"sku":"JFMSV10028","price":137.99,"currency_code":"USD","in_stock":true},{"title":"G","offer_id":46918469058815,"sku":"JFMSV10028-G","price":140.06,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/71l8S8f7E0L._AC_SL1500.jpg?v=1740702876"},{"product_id":"12-3-way-brass-motorized-ball-valve-2-wire-ac110-230v-t-type-standard-port-with-manual-function-ip67","title":"1\/2\" 3 Way Brass Motorized Ball Valve,  2 Wire, AC110-230V,  T Type,  Standard Port with Manual Function,  IP67","description":"\u003cbody\u003e \n\n\n    \u003cstyle\u003e\n        @media only screen and (max-width: 600px) {\n        }\n    \u003c\/style\u003e\n\n\n    \u003cdiv class=\"desktop-only\"\u003e\n        \u003c!-- PC --\u003e\n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; line-height: 26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 10px; color: black; font-family: Arial;\"\u003eDesigned for durability, this 3-way valve features multiple voltage designs, built-in limit switches, 2-wire control, and a capacitor return for efficient current and water use. Made of robust brass with NPT female thread connection, it's ideal for HVAC, water treatment, and automatic systems. The compact size allows space-efficient integration into pipelines, outperforming multiple one-way valves.\u003c\/p\u003e\n        \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/features-3%20Ways.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFLOW DIRECTION ( T Type)\u003c\/strong\u003e\u003c\/p\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eSituation 1: \u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eWith power, water flows from the LEFT port to the RIGHT port. Without power, water flows from the LEFT port to the BOTTOM port.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eSituation 2: \u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eWith power, water flows from the RIGHT to the LEFT port. Without power, water flows from the BOTTOM to the LEFT port.\u003c\/p\u003e \n \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/T-type%281%29.jpg\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n          \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e \n \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV10035\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e2 Wire\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1\/2\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eO-ring\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eFKM\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eBrass\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e0 - 5 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e110-230V AC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e5 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e3 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e2°C to 90°C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e70,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eStandard\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eActuator Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003ePPO\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e-15°C to 50°C\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eIP67\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/CE.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP67 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNO. This product can expose you to chemicals including lead, which is known to the State of California to cause cancer and birth defects or other reproductive harm.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n\u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves shown in this sheet are equipped with a manual operation function. You can manually open or close the valve safely, and this design allows for operation even in the absence of power, providing flexibility and reliability. \u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP67 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n           \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP67. The 6 in IP67 represents complete dust - tightness. The 7 in IP67 indicates protection against water immersion up to 1 meter for 30 minutes. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/IP67.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/Manual%20for%20Tonhe.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n    \u003cdiv class=\"mobile-only\"\u003e\n        \u003c!-- APP --\u003e\n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; line-height:26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 0px; color: black; font-family: Arial;\"\u003eDesigned for durability, this 3-way valve features multiple voltage designs, built-in limit switches, 2-wire control, and a capacitor return for efficient current and water use. Made of robust brass with NPT female thread connection, it's ideal for HVAC, water treatment, and automatic systems. The compact size allows space-efficient integration into pipelines, outperforming multiple one-way valves.\u003c\/p\u003e\n            \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/features-3%20Ways-app.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-bottom:10px; margin-top:20px; color: black;\"\u003e\u003cstrong\u003eAPPLICATION\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFLOW DIRECTION ( T Type)\u003c\/strong\u003e\u003c\/p\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eSituation 1: \u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eWith power, water flows from the LEFT port to the RIGHT port. Without power, water flows from the LEFT port to the BOTTOM port.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eSituation 2: \u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eWith power, water flows from the RIGHT to the LEFT port. Without power, water flows from the BOTTOM to the LEFT port.\u003c\/p\u003e \n \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/T-type%281%29.jpg\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n      \u003cp style=\"font-size: 16px; text-align: left; margin-bottom:10px; margin-top:20px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n         \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV10035\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e2 Wire\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1\/2\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eO-ring\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eFKM\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eBrass\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e0 - 5 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e110-230V AC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e5 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e3 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e2°C to 90°C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e70,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eStandard\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eActuator Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003ePPO\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e-15°C to 50°C\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eIP67\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/CE.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n       \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP67 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNO. This product can expose you to chemicals including lead, which is known to the State of California to cause cancer and birth defects or other reproductive harm.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n    \u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                 \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves shown in this sheet are equipped with a manual operation function. You can manually open or close the valve safely, and this design allows for operation even in the absence of power, providing flexibility and reliability. \u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP67 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP67. The 6 in IP67 represents complete dust - tightness. The 7 in IP67 indicates protection against water immersion up to 1 meter for 30 minutes. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/IP67.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material-APP.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/Manual%20for%20Tonhe.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n    \u003cscript\u003e\n\n        \/\/ Detect the user agent (User Agent) to determine the device type.\n        const isMobile = window.matchMedia(\"only screen and (max-width: 600px)\").matches;\n        const desktopContent = document.querySelector('.desktop-only');\n        const mobileContent = document.querySelector('.mobile-only');\n\n        if (isMobile) {\n            \/\/ APP\n            console.log('The user is accessing from a mobile phone or tablet device.');\n            desktopContent.style.display = 'none';\n            mobileContent.style.display = 'block';\n        } else {\n            \/\/ PC\n            console.log('The user is accessing from a desktop device.');            \n            desktopContent.style.display = 'block';\n            mobileContent.style.display = 'none';\n        }\n    \u003c\/script\u003e\n\n\n\n\u003c\/body\u003e","brand":"U.S. Solid","offers":[{"title":"NPT","offer_id":46918443794687,"sku":"JFMSV10035","price":80.97,"currency_code":"USD","in_stock":true},{"title":"G","offer_id":46918443827455,"sku":"JFMSV10035-G","price":77.87,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/71wpOyZVTQL._AC_SL1500.jpg?v=1740706393"},{"product_id":"34-3-way-brass-motorized-ball-valve-2-wire-ac110-230v-t-type-standard-port-with-manual-function-ip67","title":"3\/4\" 3 Way Brass Motorized Ball Valve,  2 Wire, AC110-230V,  T Type,  Standard Port with Manual Function,  IP67","description":"\u003cbody\u003e \n\n\n    \u003cstyle\u003e\n        @media only screen and (max-width: 600px) {\n        }\n    \u003c\/style\u003e\n\n\n    \u003cdiv class=\"desktop-only\"\u003e\n        \u003c!--  --\u003e\n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; line-height: 26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 10px; color: black; font-family: Arial;\"\u003eDesigned for durability, this 3-way valve features multiple voltage designs, built-in limit switches, 2-wire control, and a capacitor return for efficient current and water use. Made of robust brass with NPT female thread connection, it's ideal for HVAC, water treatment, and automatic systems. The compact size allows space-efficient integration into pipelines, outperforming multiple one-way valves.\u003c\/p\u003e\n        \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/features-3%20Ways.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFLOW DIRECTION ( T Type)\u003c\/strong\u003e\u003c\/p\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eSituation 1: \u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eWith power, water flows from the LEFT port to the RIGHT port. Without power, water flows from the LEFT port to the BOTTOM port.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eSituation 2: \u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eWith power, water flows from the RIGHT to the LEFT port. Without power, water flows from the BOTTOM to the LEFT port.\u003c\/p\u003e \n \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/T-type%281%29.jpg\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n          \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e \n \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV10036\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e2 Wire\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e3\/4\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eO-ring\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eFKM\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eBrass\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e0 - 5 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e110-230V AC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e5 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e3 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e2°C to 90°C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e70,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eStandard\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eActuator Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003ePPO\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e-15°C to 50°C\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eIP67\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/CE.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP67 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNO. This product can expose you to chemicals including lead, which is known to the State of California to cause cancer and birth defects or other reproductive harm.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n\u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves shown in this sheet are equipped with a manual operation function. You can manually open or close the valve safely, and this design allows for operation even in the absence of power, providing flexibility and reliability. \u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP67 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n           \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP67. The 6 in IP67 represents complete dust - tightness. The 7 in IP67 indicates protection against water immersion up to 1 meter for 30 minutes. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/IP67.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/Manual%20for%20Tonhe.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n    \u003cdiv class=\"mobile-only\"\u003e\n        \u003c!--  --\u003e\n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; line-height:26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 0px; color: black; font-family: Arial;\"\u003eDesigned for durability, this 3-way valve features multiple voltage designs, built-in limit switches, 2-wire control, and a capacitor return for efficient current and water use. Made of robust brass with NPT female thread connection, it's ideal for HVAC, water treatment, and automatic systems. The compact size allows space-efficient integration into pipelines, outperforming multiple one-way valves.\u003c\/p\u003e\n            \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/features-3%20Ways-app.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-bottom:10px; margin-top:20px; color: black;\"\u003e\u003cstrong\u003eAPPLICATION\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFLOW DIRECTION ( T Type)\u003c\/strong\u003e\u003c\/p\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eSituation 1: \u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eWith power, water flows from the LEFT port to the RIGHT port. Without power, water flows from the LEFT port to the BOTTOM port.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eSituation 2: \u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eWith power, water flows from the RIGHT to the LEFT port. Without power, water flows from the BOTTOM to the LEFT port.\u003c\/p\u003e \n \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/T-type%281%29.jpg\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n      \u003cp style=\"font-size: 16px; text-align: left; margin-bottom:10px; margin-top:20px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n         \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV10036\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e2 Wire\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e3\/4\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eO-ring\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eFKM\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eBrass\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e0 - 5 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e110-230V AC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e5 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e3 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e2°C to 90°C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e70,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eStandard\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eActuator Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003ePPO\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e-15°C to 50°C\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eIP67\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/CE.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n       \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP67 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNO. This product can expose you to chemicals including lead, which is known to the State of California to cause cancer and birth defects or other reproductive harm.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n    \u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                 \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves shown in this sheet are equipped with a manual operation function. You can manually open or close the valve safely, and this design allows for operation even in the absence of power, providing flexibility and reliability. \u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP67 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP67. The 6 in IP67 represents complete dust - tightness. The 7 in IP67 indicates protection against water immersion up to 1 meter for 30 minutes. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/IP67.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material-APP.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/Manual%20for%20Tonhe.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n    \u003cscript\u003e\n\n        \/\/ (User Agent)\n        const isMobile = window.matchMedia(\"only screen and (max-width: 600px)\").matches;\n        const desktopContent = document.querySelector('.desktop-only');\n        const mobileContent = document.querySelector('.mobile-only');\n\n        if (isMobile) {\n            \/\/ \n            console.log('');\n            \/\/ ，\n            desktopContent.style.display = 'none';\n            mobileContent.style.display = 'block';\n        } else {\n            \/\/ \n            console.log('');            \n            \/\/ ，\n            desktopContent.style.display = 'block';\n            mobileContent.style.display = 'none';\n        }\n    \u003c\/script\u003e\n\n\n\n\u003c\/body\u003e","brand":"U.S. Solid","offers":[{"title":"NPT","offer_id":46918442942719,"sku":"JFMSV10036","price":95.97,"currency_code":"USD","in_stock":true},{"title":"G","offer_id":46918442975487,"sku":"JFMSV10036-G","price":89.87,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/71ArvVD0gdL._AC_SL1500.jpg?v=1740727813"},{"product_id":"1-3-way-brass-motorized-ball-valve-2-wire-ac110-230v-t-type-standard-port-with-manual-function-ip67","title":"1\" 3 Way Brass Motorized Ball Valve,  2 Wire, AC110-230V,  T Type,  Standard Port with Manual Function,  IP67","description":"\u003cbody\u003e \n\n\n    \u003cstyle\u003e\n        @media only screen and (max-width: 600px) {\n        }\n    \u003c\/style\u003e\n\n\n    \u003cdiv class=\"desktop-only\"\u003e\n       \n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; line-height: 26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 10px; color: black; font-family: Arial;\"\u003eDesigned for durability, this 3-way valve features multiple voltage designs, built-in limit switches, 2-wire control, and a capacitor return for efficient current and water use. Made of robust brass with NPT female thread connection, it's ideal for HVAC, water treatment, and automatic systems. The compact size allows space-efficient integration into pipelines, outperforming multiple one-way valves.\u003c\/p\u003e\n        \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/features-3%20Ways.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFLOW DIRECTION ( T Type)\u003c\/strong\u003e\u003c\/p\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eSituation 1: \u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eWith power, water flows from the LEFT port to the RIGHT port. Without power, water flows from the LEFT port to the BOTTOM port.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eSituation 2: \u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eWith power, water flows from the RIGHT to the LEFT port. Without power, water flows from the BOTTOM to the LEFT port.\u003c\/p\u003e \n \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/T-type%281%29.jpg\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n          \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e \n \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV10037\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e2 Wire\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eO-ring\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eFKM\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eBrass\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e0 - 5 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e110-230V AC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e5 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e3 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e2°C to 90°C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e70,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eStandard\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eActuator Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003ePPO\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e-15°C to 50°C\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eIP67\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/CE.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP67 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNO. This product can expose you to chemicals including lead, which is known to the State of California to cause cancer and birth defects or other reproductive harm.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n\u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves shown in this sheet are equipped with a manual operation function. You can manually open or close the valve safely, and this design allows for operation even in the absence of power, providing flexibility and reliability. \u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP67 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n           \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP67. The 6 in IP67 represents complete dust - tightness. The 7 in IP67 indicates protection against water immersion up to 1 meter for 30 minutes. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/IP67.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/Manual%20for%20Tonhe.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n    \u003cdiv class=\"mobile-only\"\u003e\n       \n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; line-height:26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 0px; color: black; font-family: Arial;\"\u003eDesigned for durability, this 3-way valve features multiple voltage designs, built-in limit switches, 2-wire control, and a capacitor return for efficient current and water use. Made of robust brass with NPT female thread connection, it's ideal for HVAC, water treatment, and automatic systems. The compact size allows space-efficient integration into pipelines, outperforming multiple one-way valves.\u003c\/p\u003e\n            \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/features-3%20Ways-app.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-bottom:10px; margin-top:20px; color: black;\"\u003e\u003cstrong\u003eAPPLICATION\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFLOW DIRECTION ( T Type)\u003c\/strong\u003e\u003c\/p\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eSituation 1: \u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eWith power, water flows from the LEFT port to the RIGHT port. Without power, water flows from the LEFT port to the BOTTOM port.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eSituation 2: \u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eWith power, water flows from the RIGHT to the LEFT port. Without power, water flows from the BOTTOM to the LEFT port.\u003c\/p\u003e \n \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/T-type%281%29.jpg\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n      \u003cp style=\"font-size: 16px; text-align: left; margin-bottom:10px; margin-top:20px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n         \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV10037\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e2 Wire\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eO-ring\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eFKM\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eBrass\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e0 - 5 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e110-230V AC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e5 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e3 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e2°C to 90°C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e70,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eStandard\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eActuator Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003ePPO\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e-15°C to 50°C\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eIP67\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/CE.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n       \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP67 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNO. This product can expose you to chemicals including lead, which is known to the State of California to cause cancer and birth defects or other reproductive harm.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n    \u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                 \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves shown in this sheet are equipped with a manual operation function. You can manually open or close the valve safely, and this design allows for operation even in the absence of power, providing flexibility and reliability. \u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP67 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP67. The 6 in IP67 represents complete dust - tightness. The 7 in IP67 indicates protection against water immersion up to 1 meter for 30 minutes. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/IP67.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material-APP.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/Manual%20for%20Tonhe.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n    \u003cscript\u003e\n\n       \n        const isMobile = window.matchMedia(\"only screen and (max-width: 600px)\").matches;\n        const desktopContent = document.querySelector('.desktop-only');\n        const mobileContent = document.querySelector('.mobile-only');\n\n        if (isMobile) {\n            \n            console.log('');\n           \n            desktopContent.style.display = 'none';\n            mobileContent.style.display = 'block';\n        } else {\n            \n            console.log('');            \n            \n            desktopContent.style.display = 'block';\n            mobileContent.style.display = 'none';\n        }\n    \u003c\/script\u003e\n\n\n\n\u003c\/body\u003e","brand":"U.S. Solid","offers":[{"title":"NPT","offer_id":46918430687487,"sku":"JFMSV10037","price":104.97,"currency_code":"USD","in_stock":true},{"title":"G","offer_id":46918430720255,"sku":"JFMSV10037-G","price":104.87,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/71wpOyZVTQL._AC_SL1500_b7bd5849-c10d-44bd-bd8d-42c7993cf0bf.jpg?v=1740728170"},{"product_id":"34-3-way-stainless-steel-motorized-ball-valve-ac110-230v-l-type-2-wire-with-manual-function-standard-port","title":"3\/4\" 3 Way Stainless Steel Motorized Ball Valve AC110-230V,  L Type, 2 Wire with Manual Function,  Standard Port","description":"\u003cstyle\u003e\n        @media only screen and (max-width: 600px) {\n        }\n    \u003c\/style\u003e\n\u003cdiv class=\"desktop-only\"\u003e\n\u003c!--  --\u003e \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top: 0px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; line-height: 26px; color: black; font-family: Arial; margin: 10px 0px 0px 0px;\"\u003eDesigned for durability, this 3-way valve features multiple voltage designs, built-in limit switches, 2-wire control, and a capacitor return for efficient current and water use. Made of robust stainless steel with NPT female thread connection, it's ideal for HVAC, water treatment, and automatic systems. The compact size allows space-efficient integration into pipelines, outperforming multiple one-way valves.\u003c\/p\u003e\n\u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/features-3%20Ways.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n\u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #ffffff;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 0px; font-size: 16px; border: 0; background-color: #ffffff;\"\u003e\n\u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eSITUATION 1\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif14.gif\" style=\"width: 100%; height: 100%;\"\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 0px; font-size: 16px; border: 0; background-color: #ffffff;\"\u003e\n\u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eSITUATION 2 \u003c\/strong\u003e\u003c\/h2\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif13.gif\" style=\"width: 100%; height: 100%;\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eFLOW DIRECTION ( L Type)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003eSituation 1: \u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eWater enters from the bottom port. With power, it flows from the left port; without power, from the right port.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003eSituation 2: \u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eWater enters from both the left and right ports. With power, it flows from the left port to the bottom; without power, from the right port to the bottom.\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/L-type%281%29.jpg\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n\u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #ffffff;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003eUSS-MSV10007\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003e2 Wire\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003e3\/4\"\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eO-ring\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003eFKM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003eSS304\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003ePTFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003e0 - 5 Seconds\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003e110-230V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003e5 W\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003e3 N m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003e1.0 Mpa\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003e2°C to 90°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003e70,000 Cycles\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003eStandard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003eNPT\/G\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eActuator Material\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003ePPO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003e-15°C to 50°C\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003eIP67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/CE.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial; line-height: 26px;\"\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eThe motor's housing is rated at IP67 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e2.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e3.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eYES. The motorized ball valve is made of lead-free stainless steel.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e4.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e5.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial; line-height: 26px;\"\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top: 20px; margin-bottom: 10px; line-height: 26px; color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves shown in this sheet are equipped with a manual operation function. You can manually open or close the valve safely, and this design allows for operation even in the absence of power, providing flexibility and reliability.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP67 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eThe valves have an ingress - protection rating of IP67. The 6 in IP67 represents complete dust - tightness. The 7 in IP67 indicates protection against water immersion up to 1 meter for 30 minutes. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/IP67-SS304.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/Manual%20for%20Tonhe.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mobile-only\"\u003e\n\u003c!--  --\u003e \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top: 0px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; line-height: 26px; color: black; font-family: Arial; margin: 0px;\"\u003eDesigned for durability, this 3-way valve features multiple voltage designs, built-in limit switches, 2-wire control, and a capacitor return for efficient current and water use. Made of robust stainless steel with NPT female thread connection, it's ideal for HVAC, water treatment, and automatic systems. The compact size allows space-efficient integration into pipelines, outperforming multiple one-way valves.\u003c\/p\u003e\n\u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/features-3%20Ways-app.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-bottom: 10px; margin-top: 20px; color: black;\"\u003e\u003cstrong\u003eAPPLICATION\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n\u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eSITUATION 1\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif14.gif\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n\u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eSITUATION 2\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif13.gif\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eFLOW DIRECTION ( L Type)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003eSituation 1: \u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eWater enters from the bottom port. With power, it flows from the left port; without power, from the right port.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003eSituation 2: \u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eWater enters from both the left and right ports. With power, it flows from the left port to the bottom; without power, from the right port to the bottom.\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/L-type%281%29.jpg\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 16px; text-align: left; margin-bottom: 10px; margin-top: 20px; color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n\u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #ffffff;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003eUSS-MSV10007\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003e2 Wire\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003e3\/4\"\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eO-ring\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003eFKM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003eSS304\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003ePTFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003e0 - 5 Seconds\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003e110-230V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003e5 W\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003e3 N m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003e1.0 Mpa\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003e2°C to 90°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003e70,000 Cycles\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003eStandard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003eNPT\/G\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eActuator Material\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003ePPO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003e-15°C to 50°C\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003eIP67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/CE.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial; line-height: 26px;\"\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eThe motor's housing is rated at IP67 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e2.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e3.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eYES. The motorized ball valve is made of lead-free stainless steel.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e4.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e5.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial; line-height: 26px;\"\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top: 20px; margin-bottom: 10px; line-height: 26px; color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves shown in this sheet are equipped with a manual operation function. You can manually open or close the valve safely, and this design allows for operation even in the absence of power, providing flexibility and reliability.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP67 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eThe valves have an ingress - protection rating of IP67. The 6 in IP67 represents complete dust - tightness. The 7 in IP67 indicates protection against water immersion up to 1 meter for 30 minutes. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/IP67-SS304.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material-APP.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/Manual%20for%20Tonhe.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"U.S. Solid","offers":[{"title":"NPT","offer_id":47077151932671,"sku":"JFMSV10007","price":115.59,"currency_code":"USD","in_stock":true},{"title":"G","offer_id":47077151965439,"sku":"JFMSV10007-G","price":114.19,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/71S4foWpRVL._AC_SL1500.jpg?v=1753663575"},{"product_id":"1-3-way-stainless-steel-motorized-ball-valve-ac110-230v-l-type-2-wire-with-manual-function-standard-port","title":"1\" 3 Way Stainless Steel Motorized Ball Valve AC110-230V,  L Type,  2 Wire with Manual Function,  Standard Port","description":"\u003cstyle\u003e\n        @media only screen and (max-width: 600px) {\n        }\n    \u003c\/style\u003e\n\u003cdiv class=\"desktop-only\"\u003e\n\u003c!--  --\u003e \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top: 0px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; line-height: 26px; color: black; font-family: Arial; margin: 10px 0px 0px 0px;\"\u003eDesigned for durability, this 3-way valve features multiple voltage designs, built-in limit switches, 2-wire control, and a capacitor return for efficient current and water use. Made of robust stainless steel with NPT female thread connection, it's ideal for HVAC, water treatment, and automatic systems. The compact size allows space-efficient integration into pipelines, outperforming multiple one-way valves.\u003c\/p\u003e\n\u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/features-3%20Ways.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n\u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #ffffff;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 0px; font-size: 16px; border: 0; background-color: #ffffff;\"\u003e\n\u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eSITUATION 1\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif14.gif\" style=\"width: 100%; height: 100%;\"\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 0px; font-size: 16px; border: 0; background-color: #ffffff;\"\u003e\n\u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eSITUATION 2 \u003c\/strong\u003e\u003c\/h2\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif13.gif\" style=\"width: 100%; height: 100%;\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eFLOW DIRECTION ( L Type)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003eSituation 1: \u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eWater enters from the bottom port. With power, it flows from the left port; without power, from the right port.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003eSituation 2: \u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eWater enters from both the left and right ports. With power, it flows from the left port to the bottom; without power, from the right port to the bottom.\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/L-type%281%29.jpg\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n\u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #ffffff;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003eUSS-MSV10008\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003e2 Wire\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003e1\"\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eO-ring\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003eFKM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003eSS304\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003ePTFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003e0 - 5 Seconds\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003e110-230V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003e5 W\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003e3 N m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003e1.0 Mpa\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003e2°C to 90°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003e70,000 Cycles\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003eStandard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003eNPT\/G\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eActuator Material\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003ePPO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003e-15°C to 50°C\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003eIP67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/CE.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial; line-height: 26px;\"\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eThe motor's housing is rated at IP67 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e2.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e3.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eYES. The motorized ball valve is made of lead-free stainless steel.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e4.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e5.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial; line-height: 26px;\"\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top: 20px; margin-bottom: 10px; line-height: 26px; color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves shown in this sheet are equipped with a manual operation function. You can manually open or close the valve safely, and this design allows for operation even in the absence of power, providing flexibility and reliability.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP67 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eThe valves have an ingress - protection rating of IP67. The 6 in IP67 represents complete dust - tightness. The 7 in IP67 indicates protection against water immersion up to 1 meter for 30 minutes. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/IP67-SS304.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/Manual%20for%20Tonhe.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mobile-only\"\u003e\n\u003c!--  --\u003e \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top: 0px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; line-height: 26px; color: black; font-family: Arial; margin: 0px;\"\u003eDesigned for durability, this 3-way valve features multiple voltage designs, built-in limit switches, 2-wire control, and a capacitor return for efficient current and water use. Made of robust stainless steel with NPT female thread connection, it's ideal for HVAC, water treatment, and automatic systems. The compact size allows space-efficient integration into pipelines, outperforming multiple one-way valves.\u003c\/p\u003e\n\u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/features-3%20Ways-app.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-bottom: 10px; margin-top: 20px; color: black;\"\u003e\u003cstrong\u003eAPPLICATION\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n\u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eSITUATION 1\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif14.gif\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n\u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eSITUATION 2\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif13.gif\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eFLOW DIRECTION ( L Type)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003eSituation 1: \u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eWater enters from the bottom port. With power, it flows from the left port; without power, from the right port.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003eSituation 2: \u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eWater enters from both the left and right ports. With power, it flows from the left port to the bottom; without power, from the right port to the bottom.\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/L-type%281%29.jpg\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 16px; text-align: left; margin-bottom: 10px; margin-top: 20px; color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n\u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #ffffff;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003eUSS-MSV10008\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003e2 Wire\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003e1\"\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eO-ring\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003eFKM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003eSS304\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003ePTFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003e0 - 5 Seconds\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003e110-230V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003e5 W\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003e3 N m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003e1.0 Mpa\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003e2°C to 90°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003e70,000 Cycles\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003eStandard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003eNPT\/G\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eActuator Material\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003ePPO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003e-15°C to 50°C\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003eIP67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/CE.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial; line-height: 26px;\"\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eThe motor's housing is rated at IP67 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e2.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e3.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eYES. The motorized ball valve is made of lead-free stainless steel.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e4.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e5.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial; line-height: 26px;\"\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top: 20px; margin-bottom: 10px; line-height: 26px; color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves shown in this sheet are equipped with a manual operation function. You can manually open or close the valve safely, and this design allows for operation even in the absence of power, providing flexibility and reliability.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP67 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eThe valves have an ingress - protection rating of IP67. The 6 in IP67 represents complete dust - tightness. The 7 in IP67 indicates protection against water immersion up to 1 meter for 30 minutes. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/IP67-SS304.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material-APP.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/Manual%20for%20Tonhe.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"U.S. Solid","offers":[{"title":"NPT","offer_id":47077149081855,"sku":"JFMSV10008","price":140.59,"currency_code":"USD","in_stock":true},{"title":"G","offer_id":47077149114623,"sku":"JFMSV10008-G","price":134.19,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/71eAygmy2mL._AC_SL1500_159208a8-b7f3-4aef-9fe2-95d6bcb6979b.jpg?v=1753427759"},{"product_id":"wifi-12-brass-remote-control-motorized-ball-valve-with-power-off-memory-ac-100-240v-plug-adapter-with-dc-5v-output-manual-switch","title":"WiFi 1\/2\" Brass Remote Control Motorized Ball Valve with Power-Off Memory, AC 100-240V Plug Adapter with DC 5V Output, Manual Switch","description":"\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e \u003cmeta content=\"width=device-width, initial-scale=1.0\" name=\"viewport\"\u003e\u003c\/p\u003e\n\u003cstyle\u003e\n        \n        .desktop-img {\n            display: block;\n        }\n        .mobile-img {\n            display: none;\n        } \n        \n        .section-title {\n            font-size: 22px;\n            line-height: 22px;\n            font-weight: bold;\n            margin: 15px 0 5px; \n            font-family: Arial;\n        }\n        \n        .section-title2 {\n            font-size: 22px;\n            line-height: 22px;\n            font-weight: bold;\n            margin: 15px 0 3px; \n            font-family: Arial;\n        }\n       \n        .section-title3 {\n            font-size: 22px;\n            line-height: 22px;\n            font-weight: bold;\n            margin: 15px 0 10px; \n            font-family: Arial;\n        }\n\n        \n        .section-description {\n            font-size: 16px;\n            line-height: 26px;\n            margin-top: 0px;\n            margin-bottom: 5px; \n            font-family: Arial;\n        }\n      \n        .faq {\n            font-size: 16px; \n            margin: 0; \n            line-height: 26px; \n            background-color: #f2f2f2; \n            padding: 5px;\n        }\n        \n        .section-description2 {\n            font-size: 16px;\n            line-height: 26px;\n            margin: 0px; \n            font-family: Arial;\n        }\n        \n.parameters-table-wrapper {\n    overflow-x: auto; \n    -webkit-overflow-scrolling: touch; \n    margin-top: 0px;\n}\n\n\n.parameters-table {\n    width: 100%;\n    min-width: 1000px;\n    border-collapse: collapse;\n    margin-top: 0px;\n}\n\n.parameters-table th, .parameters-table td {\n    border-top: 1.2px solid #a6a6a6; \n    border-bottom: 1.2px solid #a6a6a6;  \n    border-left: none;  \n    border-right: none;  \n    padding: 5px 2px;\n    text-align: left;\n    font-size: 16px;\n    line-height: 16px;\n}\n\n.parameters-table th {\n    background-color: #f2f2f2;\n    color: #2c2c2c;\n    font-weight: bold;\n}\n\n\n.parameters-table .bg-gray {\n    background-color: #f2f2f2;  \n}\n\n\n.options-table-wrapper {\n    overflow-x: auto; \n    -webkit-overflow-scrolling: touch; \n    margin-top: 0px;\n}\n\n.options-table {\n    width: 100%;\n    min-width: 1000px; \n    border-collapse: collapse;\n    margin-top: 0px;\n    box-shadow: 0 6px 25px rgba(0, 0, 0, 0.1); \n}\n\n.options-table th, .options-table td {\n    border: 2px solid #000;  \n    padding: 5px 2px;  \n    text-align: center;\n    font-size: 16px;\n    line-height: 16px;\n}\n\n.options-table th {\n    background-color: #f2f2f2;\n    color: #2c2c2c;\n    font-weight: bold;\n}\n\n\n.parameters-table2 {\n    width: 100%;\n    min-width: 1000px; \n    border-collapse: collapse;\n    margin-top: 0px;\n}\n\n.parameters-table2 th, .parameters-table2 td {\n    border-top: 1.2px solid #a6a6a6;  \n    border-bottom: 1.2px solid #a6a6a6; \n    border-left: none;  \n    border-right: none; \n    padding: 5px 2px;\n    text-align: center;\n    font-size: 16px;\n    line-height: 16px;\n}\n\n.parameters-table2 th {\n    background-color: #f2f2f2;\n    color: #2c2c2c;\n    font-weight: bold;\n}\n\n\n.parameters-table2 .bg-gray {\n    background-color: #f2f2f2;  \n}\n\n\n.options-table-wrapper2 {\n    overflow-x: auto; \n    -webkit-overflow-scrolling: touch; \n    margin-top: 0px;\n}\n\n        .instruction-container {\n             display: flex;\n             justify-content: space-between;\n             align-items: flex-start;\n             gap: 10px; \/* Adds space between the video and the text *\/\n             margin-bottom: 0px; \/* Adds some space below the section *\/\n        }\n\n      \n        .img-container {\n              width: 50%; \n             display: flex;\n             justify-content: center; \n        }\n\n      \n        .text-container {\n               width: 50%; \n             font-size: 16px;\n             font-family: Arial;\n             \n         }\n\n         .instruction-container2 {\n             display: flex;\n             justify-content: space-between;\n             align-items: flex-start;\n             gap: 10px; \/* Adds space between the video and the text *\/\n             margin-bottom: 0px; \/* Adds some space below the section *\/\n        }\n\n      \n        .img-container2 {\n             width: 50%; \n             display: flex;\n             justify-content: center; \n        }\n\n      \n        .text-container2 {\n             width: 50%; \n            display: flex;\n             justify-content: center;\n         }\n\n\/* FAQ专属 图片+文字容器 40%+60%占比 - 不影响其他instruction-container *\/\n.instruction-container-faq {\n    display: flex;\n    justify-content: space-between;\n    align-items: flex-start;\n    gap: 10px;\n    margin-bottom: 0px;\n}\n.img-container-faq {\n    width: 35%; \/* FAQ图片占40% *\/\n    display: flex;\n    justify-content: center;\n}\n.text-container-faq {\n    width: 65%; \/* FAQ文字占60% *\/\n    font-size: 16px;\n    font-family: Arial;\n}\n\/* FAQ专属 移动端适配 - 自动上下排列 *\/\n@media (max-width: 768px) {\n    .instruction-container-faq {\n        flex-direction: column;\n        align-items: center;\n    }\n    .img-container-faq, .text-container-faq {\n        width: 100%;\n        margin-bottom: 0px;\n    }\n}\n\n@media (max-width: 768px) {\n    .parameters-table th, .parameters-table td {\n        font-size: 14px; \n        padding: 8px 4px; \n    }\n\n   \n    .options-table th, .options-table td {\n        font-size: 14px; \n        padding: 8px 4px;\n    }\n\n    .parameters-table-wrapper {\n        overflow-x: auto;\n    }\n    .parameters-table2 th, .parameters-table2 td {\n        font-size: 14px; \n        padding: 8px 4px; \n    }\n    .parameters-table-wrapper2 {\n        overflow-x: auto;\n    }\n    .desktop-img {\n                display: none;\n            }\n            .mobile-img {\n                display: block; \n            }\n    .instruction-container {\n                flex-direction: column; \n                align-items: center;\n            }\n\n            .img-container, .text-container {\n                width: 100%; \/* Both take full width *\/\n                margin-bottom: 0px; \n            }\n            .instruction-container2 {\n                flex-direction: column; \n                align-items: center;\n            }\n\n            .img-container2, .text-container2 {\n                width: 100%; \/* Both take full width *\/\n                margin-bottom: 0px; \n            }\n    \n}\n\n@media (max-width: 480px) {\n    .parameters-table th, .parameters-table td {\n        font-size: 12px; \n        padding: 6px 3px; \n    }\n\n    \n    .options-table th, .options-table td {\n        font-size: 12px; \n    }\n\n    .parameters-table-wrapper {\n        overflow-x: auto;\n    }\n    .parameters-table2 th, .parameters-table2 td {\n        font-size: 12px; \n        padding: 6px 3px; \n    }\n    .parameters-table-wrapper2 {\n        overflow-x: auto;\n    }\n    .desktop-img {\n                display: none; \n            }\n            .mobile-img {\n                display: block; \n            }\n    .instruction-container {\n                flex-direction: column; \n            }\n            .instruction-container2 {\n                flex-direction: column; \n            }\n    \n}\n    \u003c\/style\u003e\n\u003c!-- background --\u003e\n\u003cp\u003e\u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/jfmsv-WiFi-plug-a.jpg\"\u003e \u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/jfmsv-WiFi-plug-a-p.jpg\"\u003e\u003c\/p\u003e\n\u003c!-- Introduction --\u003e\n\u003cdiv\u003e\n\u003ch2 class=\"section-title\"\u003eIntroduction\u003c\/h2\u003e\n\u003cp class=\"section-description\"\u003eThe U.S. Solid Smart Motorized Ball Valve is a cutting-edge motorized ball valve with built-in smart control technology. Easily control the valve using your mobile device via Wi-Fi, with no complicated installation required. Simply download the app, connect to Wi-Fi, and remotely open or close the valve with a few taps. Enjoy unmatched convenience and ease of use compared to traditional valves. Perfect for controlling water, gas, or other fluids with reliable and accurate control every time.\u003cbr\u003eCompared to the basic model of smart motorized ball valve (powered by DC 5V via USB), this series comes with a plug-in AC-DC adapter that converts AC 100V-240V to DC 5V, enabling direct power supply from standard household AC outlets.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- Applications--\u003e\n\u003ch2 class=\"section-title2\"\u003eApplications\u003c\/h2\u003e\n\u003cp\u003e\u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFSV\/JFSV-smart-plug-a.jpg\"\u003e \u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFSV\/JFSV-a-p.jpg\"\u003e\u003c\/p\u003e\n\u003c!-- Smart Control--\u003e\n\u003ch2 class=\"section-title2\"\u003eSmart Control\u003c\/h2\u003e\n\u003cp class=\"section-description\"\u003eThe smart motorized ball valve features a smart-control function, providing you with the convenience of controlling your valve using your cellphone. Furthermore, once the valve is connected to your WiFi, you can remotely control the valve even when you are away from home.\u003cbr\u003eThis feature allows for seamless and convenient operation of the valve from anywhere at any time.In addition to its smart control capabilities, the motorized ball valve is also equipped with a manual switch, providing an added layer of assurance and peace of mind.\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFSV\/JFSV-smart-plug.jpg\"\u003e \u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFSV\/JFSV-smart-plug-p-1.jpg\"\u003e \u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFSV\/JFSV-smart-plug-p-2.jpg\"\u003e\u003c\/p\u003e\n\u003c!-- Features --\u003e\n\u003cdiv\u003e\n\u003ch2 class=\"section-title\"\u003eFeatures\u003c\/h2\u003e\n\u003cul class=\"section-description2\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eOpen Percentage:\u003c\/strong\u003e Set the open percentage for precise flow regulation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePlug Connection:\u003c\/strong\u003e Equipped with an included AC-DC adapter (converts AC 100V–240V to DC 5V) for direct wall outlet power supply.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNormally Closed:\u003c\/strong\u003e Closed when unpowered, opens when energized.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNPT\/G Threading:\u003c\/strong\u003e NPT (National Pipe Taper) and G (BSPP) threading to accommodate diverse global specifications, ensuring a secure seal with \u003ca href=\"https:\/\/ussolid.com\/products\/u-s-solid-10-rolls-0-7-inch-w-x-905-inches-l-teflon-tape-plumbers-tape-yellow-shell-html?_pos=3\u0026amp;_sid=7aa2e2725\u0026amp;_ss=r\" target=\"_blank\"\u003eteflon tape\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eValve Body Material:\u003c\/strong\u003e Constructed from corrosion-resistant brass. Not suitable for drinking water applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePTFE Seal:\u003c\/strong\u003e Superior to NBR and Viton in sealing, temperature, and pressure resistance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFSV\/jfsv-smart-plug-ss.jpg\"\u003e \u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFSV\/jfsv-smart-plug-ss-p.jpg\"\u003e\u003c\/p\u003e\n\u003c!-- Technical Data --\u003e\n\u003ch2 class=\"section-title3\"\u003eTechnical Data\u003c\/h2\u003e\n\u003cdiv class=\"parameters-table-wrapper\"\u003e\n\u003ctable class=\"parameters-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eUSS-MSV00451\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eProduct Name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eSmart Motorized Ball Valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eBore Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eFull Port\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eLife Expectancy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e80,000-100,000 Cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eStatus Indicator\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eYes\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eFlow Aperture\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e15 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eThread Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eNPT\/G\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eOperating State\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eNormally Closed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eSize\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1\/2\"\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eWiring Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003ePlug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eValve Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eBrass\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eBall Seal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003ePTFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eOperating Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e8-10 Seconds\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eWorking Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eConverts AC 100V–240V to DC 5V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eMax Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e5W\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eMax Torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e10 N·m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eMedium Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e32℉ to 194℉\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eAmbient Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-4℉ to 113℉\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eMax Medium Pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e145 PSI (1.0 Mpa)\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eCompatible Media\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eWater, air, oil and gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eGross Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1.81 lbs\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003ePackage Dimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e6.30\"x4.72\"x4.13\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eUSB Cable Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2.1 m \/ 6.9 ft\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp class=\"section-description\"\u003e*To view the full table on mobile, please swipe left or right on the screen.\u003c\/p\u003e\n\u003c!-- User Manual --\u003e\n\n\u003ch2 class=\"section-title3\"\u003eCE Certified Quality \u0026amp; Safety\u003c\/h2\u003e\n\u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/CE\/CE.jpg\"\u003e\n\u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/CE\/CE.jpg\"\u003e\n\u003ch2 class=\"section-title\"\u003eUser Manual\u003c\/h2\u003e\n\u003cp class=\"section-description\"\u003eTo learn how to use this product, please refer to the \u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/Instruction%20Manual-U.S.%20Solid%20Smart%20Motorized%20Ball%20Valve2025.pdf\" target=\"_blank\"\u003euser manual\u003c\/a\u003e or watch the \u003ca href=\"https:\/\/youtu.be\/PfpgH29YU-s?list=TLGGw48OMJtyzq8yMTA3MjAyNQ\" target=\"_blank\"\u003etutorial video\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\u003cstrong\u003eNote:\u003c\/strong\u003eThe GIF demonstrates flow control by setting Open Percentage (100% = fully open, 0% = fully closed).\u003c\/p\u003e\n\u003cdiv class=\"instruction-container\"\u003e\n\u003cdiv class=\"img-container\"\u003e\u003cimg alt=\"\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif11.gif\" style=\"width: 100%; height: auto;\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"text-container\"\u003e\u003cimg alt=\"\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif12.gif\" style=\"width: 100%; height: auto;\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- FAQ --\u003e\n\u003ch2 class=\"section-title\"\u003eFAQ\u003c\/h2\u003e\n\u003cp class=\"faq\"\u003e\u003cb\u003eProblem 1: What's the difference between this series and the basic Smart Motorized Ball Valve model?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003eWhile the basic model operates on DC5V via USB, this series includes a plug adapter that converts AC100V-240V to DC5V for direct wall outlet connection.\u003c\/p\u003e\n\u003cp class=\"faq\"\u003e\u003cb\u003eProblem 2: Can the Smart Motorized Ball Valve only be controlled via the app?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\u003cstrong\u003eNo\u003c\/strong\u003e, it also features a manual push-button for local control.\u003c\/p\u003e\n\u003cp class=\"faq\"\u003e\u003cb\u003eProblem 3: This smart ball valve is marked as normally closed – can its power-off passage state be modified via the app?\u003c\/b\u003e\u003c\/p\u003e\n\u003cdiv class=\"instruction-container-faq\"\u003e\n\u003cdiv class=\"img-container-faq\"\u003e\u003cimg alt=\"\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFSV\/jfsv-smart-plug-off.jpg\" style=\"width: 100%; height: auto;\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"text-container-faq\"\u003e\n\u003cp class=\"section-title\"\u003eTap “Settings” to set\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003eThis smart ball valve is factory default set to a normally closed state (valve passage closes automatically when power is lost), and you can freely adjust its power-off working state according to your actual usage needs through the dedicated mobile app.\u003c\/p\u003e\n\u003cp class=\"section-title\"\u003eThree states\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003eSelect the specific power-off state you need for the valve, and the setting will be automatically saved immediately once you make your selection, no additional save operation is required.\u003c\/p\u003e\n\u003cul class=\"section-description2\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eOff:\u003c\/strong\u003e The valve passage stays closed when power is lost (consistent with the default setting).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOn:\u003c\/strong\u003e The valve passage remains open when power is lost.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMemory:\u003c\/strong\u003e The valve passage maintains its last working position before the power failure.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp class=\"faq\"\u003e\u003cb\u003eProblem 4: What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n\u003cul class=\"section-description2\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eFull Port:\u003c\/strong\u003e Matches pipe diameter, minimal flow restriction, ideal for high flow and low pressure drop.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard Port:\u003c\/strong\u003e Smaller than pipe diameter, higher resistance, suitable for general flow and pressure needs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"faq\"\u003e\u003cb\u003eProblem 5: Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\u003cstrong\u003eNo.\u003c\/strong\u003e This valve is made of brass and is not suitable for drinking water applications.\u003c\/p\u003e","brand":"U.S. Solid","offers":[{"title":"NPT","offer_id":47129048940799,"sku":"JFMSV00451","price":94.49,"currency_code":"USD","in_stock":true},{"title":"G","offer_id":47158011887871,"sku":"JFMSV00451-G","price":87.89,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/1_f334f829-8c01-4798-848c-4bcf4618a4c9.jpg?v=1755586522"},{"product_id":"wifi-34-brass-remote-control-motorized-ball-valve-with-power-off-memory-ac-100-240v-plug-adapter-with-dc-5v-output-manual-switch","title":"WiFi 3\/4\" Brass Remote Control Motorized Ball Valve with Power-Off Memory, AC 100-240V Plug Adapter with DC 5V Output, Manual Switch","description":"\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e \u003cmeta content=\"width=device-width, initial-scale=1.0\" name=\"viewport\"\u003e\u003c\/p\u003e\n\u003cstyle\u003e\n        \n        .desktop-img {\n            display: block;\n        }\n        .mobile-img {\n            display: none;\n        } \n        \n        .section-title {\n            font-size: 22px;\n            line-height: 22px;\n            font-weight: bold;\n            margin: 15px 0 5px; \n            font-family: Arial;\n        }\n        \n        .section-title2 {\n            font-size: 22px;\n            line-height: 22px;\n            font-weight: bold;\n            margin: 15px 0 3px; \n            font-family: Arial;\n        }\n       \n        .section-title3 {\n            font-size: 22px;\n            line-height: 22px;\n            font-weight: bold;\n            margin: 15px 0 10px; \n            font-family: Arial;\n        }\n\n        \n        .section-description {\n            font-size: 16px;\n            line-height: 26px;\n            margin-top: 0px;\n            margin-bottom: 5px; \n            font-family: Arial;\n        }\n      \n        .faq {\n            font-size: 16px; \n            margin: 0; \n            line-height: 26px; \n            background-color: #f2f2f2; \n            padding: 5px;\n        }\n        \n        .section-description2 {\n            font-size: 16px;\n            line-height: 26px;\n            margin: 0px; \n            font-family: Arial;\n        }\n        \n.parameters-table-wrapper {\n    overflow-x: auto; \n    -webkit-overflow-scrolling: touch; \n    margin-top: 0px;\n}\n\n\n.parameters-table {\n    width: 100%;\n    min-width: 1000px;\n    border-collapse: collapse;\n    margin-top: 0px;\n}\n\n.parameters-table th, .parameters-table td {\n    border-top: 1.2px solid #a6a6a6; \n    border-bottom: 1.2px solid #a6a6a6;  \n    border-left: none;  \n    border-right: none;  \n    padding: 5px 2px;\n    text-align: left;\n    font-size: 16px;\n    line-height: 16px;\n}\n\n.parameters-table th {\n    background-color: #f2f2f2;\n    color: #2c2c2c;\n    font-weight: bold;\n}\n\n\n.parameters-table .bg-gray {\n    background-color: #f2f2f2;  \n}\n\n\n.options-table-wrapper {\n    overflow-x: auto; \n    -webkit-overflow-scrolling: touch; \n    margin-top: 0px;\n}\n\n.options-table {\n    width: 100%;\n    min-width: 1000px; \n    border-collapse: collapse;\n    margin-top: 0px;\n    box-shadow: 0 6px 25px rgba(0, 0, 0, 0.1); \n}\n\n.options-table th, .options-table td {\n    border: 2px solid #000;  \n    padding: 5px 2px;  \n    text-align: center;\n    font-size: 16px;\n    line-height: 16px;\n}\n\n.options-table th {\n    background-color: #f2f2f2;\n    color: #2c2c2c;\n    font-weight: bold;\n}\n\n\n.parameters-table2 {\n    width: 100%;\n    min-width: 1000px; \n    border-collapse: collapse;\n    margin-top: 0px;\n}\n\n.parameters-table2 th, .parameters-table2 td {\n    border-top: 1.2px solid #a6a6a6;  \n    border-bottom: 1.2px solid #a6a6a6; \n    border-left: none;  \n    border-right: none; \n    padding: 5px 2px;\n    text-align: center;\n    font-size: 16px;\n    line-height: 16px;\n}\n\n.parameters-table2 th {\n    background-color: #f2f2f2;\n    color: #2c2c2c;\n    font-weight: bold;\n}\n\n\n.parameters-table2 .bg-gray {\n    background-color: #f2f2f2;  \n}\n\n\n.options-table-wrapper2 {\n    overflow-x: auto; \n    -webkit-overflow-scrolling: touch; \n    margin-top: 0px;\n}\n\n        .instruction-container {\n             display: flex;\n             justify-content: space-between;\n             align-items: flex-start;\n             gap: 10px; \/* Adds space between the video and the text *\/\n             margin-bottom: 0px; \/* Adds some space below the section *\/\n        }\n\n      \n        .img-container {\n              width: 50%; \n             display: flex;\n             justify-content: center; \n        }\n\n      \n        .text-container {\n               width: 50%; \n             font-size: 16px;\n             font-family: Arial;\n             \n         }\n\n         .instruction-container2 {\n             display: flex;\n             justify-content: space-between;\n             align-items: flex-start;\n             gap: 10px; \/* Adds space between the video and the text *\/\n             margin-bottom: 0px; \/* Adds some space below the section *\/\n        }\n\n      \n        .img-container2 {\n             width: 50%; \n             display: flex;\n             justify-content: center; \n        }\n\n      \n        .text-container2 {\n             width: 50%; \n            display: flex;\n             justify-content: center;\n         }\n\n\/* FAQ专属 图片+文字容器 40%+60%占比 - 不影响其他instruction-container *\/\n.instruction-container-faq {\n    display: flex;\n    justify-content: space-between;\n    align-items: flex-start;\n    gap: 10px;\n    margin-bottom: 0px;\n}\n.img-container-faq {\n    width: 35%; \/* FAQ图片占40% *\/\n    display: flex;\n    justify-content: center;\n}\n.text-container-faq {\n    width: 65%; \/* FAQ文字占60% *\/\n    font-size: 16px;\n    font-family: Arial;\n}\n\/* FAQ专属 移动端适配 - 自动上下排列 *\/\n@media (max-width: 768px) {\n    .instruction-container-faq {\n        flex-direction: column;\n        align-items: center;\n    }\n    .img-container-faq, .text-container-faq {\n        width: 100%;\n        margin-bottom: 0px;\n    }\n}\n\n@media (max-width: 768px) {\n    .parameters-table th, .parameters-table td {\n        font-size: 14px; \n        padding: 8px 4px; \n    }\n\n   \n    .options-table th, .options-table td {\n        font-size: 14px; \n        padding: 8px 4px;\n    }\n\n    .parameters-table-wrapper {\n        overflow-x: auto;\n    }\n    .parameters-table2 th, .parameters-table2 td {\n        font-size: 14px; \n        padding: 8px 4px; \n    }\n    .parameters-table-wrapper2 {\n        overflow-x: auto;\n    }\n    .desktop-img {\n                display: none;\n            }\n            .mobile-img {\n                display: block; \n            }\n    .instruction-container {\n                flex-direction: column; \n                align-items: center;\n            }\n\n            .img-container, .text-container {\n                width: 100%; \/* Both take full width *\/\n                margin-bottom: 0px; \n            }\n            .instruction-container2 {\n                flex-direction: column; \n                align-items: center;\n            }\n\n            .img-container2, .text-container2 {\n                width: 100%; \/* Both take full width *\/\n                margin-bottom: 0px; \n            }\n    \n}\n\n@media (max-width: 480px) {\n    .parameters-table th, .parameters-table td {\n        font-size: 12px; \n        padding: 6px 3px; \n    }\n\n    \n    .options-table th, .options-table td {\n        font-size: 12px; \n    }\n\n    .parameters-table-wrapper {\n        overflow-x: auto;\n    }\n    .parameters-table2 th, .parameters-table2 td {\n        font-size: 12px; \n        padding: 6px 3px; \n    }\n    .parameters-table-wrapper2 {\n        overflow-x: auto;\n    }\n    .desktop-img {\n                display: none; \n            }\n            .mobile-img {\n                display: block; \n            }\n    .instruction-container {\n                flex-direction: column; \n            }\n            .instruction-container2 {\n                flex-direction: column; \n            }\n    \n}\n    \u003c\/style\u003e\n\u003c!-- background --\u003e\n\u003cp\u003e\u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/jfmsv-WiFi-plug-a.jpg\"\u003e \u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/jfmsv-WiFi-plug-a-p.jpg\"\u003e\u003c\/p\u003e\n\u003c!-- Introduction --\u003e\n\u003cdiv\u003e\n\u003ch2 class=\"section-title\"\u003eIntroduction\u003c\/h2\u003e\n\u003cp class=\"section-description\"\u003eThe U.S. Solid Smart Motorized Ball Valve is a cutting-edge motorized ball valve with built-in smart control technology. Easily control the valve using your mobile device via Wi-Fi, with no complicated installation required. Simply download the app, connect to Wi-Fi, and remotely open or close the valve with a few taps. Enjoy unmatched convenience and ease of use compared to traditional valves. Perfect for controlling water, gas, or other fluids with reliable and accurate control every time.\u003cbr\u003eCompared to the basic model of smart motorized ball valve (powered by DC 5V via USB), this series comes with a plug-in AC-DC adapter that converts AC 100V-240V to DC 5V, enabling direct power supply from standard household AC outlets.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- Applications--\u003e\n\u003ch2 class=\"section-title2\"\u003eApplications\u003c\/h2\u003e\n\u003cp\u003e\u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFSV\/JFSV-smart-plug-a.jpg\"\u003e \u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFSV\/JFSV-a-p.jpg\"\u003e\u003c\/p\u003e\n\u003c!-- Smart Control--\u003e\n\u003ch2 class=\"section-title2\"\u003eSmart Control\u003c\/h2\u003e\n\u003cp class=\"section-description\"\u003eThe smart motorized ball valve features a smart-control function, providing you with the convenience of controlling your valve using your cellphone. Furthermore, once the valve is connected to your WiFi, you can remotely control the valve even when you are away from home.\u003cbr\u003eThis feature allows for seamless and convenient operation of the valve from anywhere at any time.In addition to its smart control capabilities, the motorized ball valve is also equipped with a manual switch, providing an added layer of assurance and peace of mind.\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFSV\/JFSV-smart-plug.jpg\"\u003e \u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFSV\/JFSV-smart-plug-p-1.jpg\"\u003e \u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFSV\/JFSV-smart-plug-p-2.jpg\"\u003e\u003c\/p\u003e\n\u003c!-- Features --\u003e\n\u003cdiv\u003e\n\u003ch2 class=\"section-title\"\u003eFeatures\u003c\/h2\u003e\n\u003cul class=\"section-description2\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eOpen Percentage:\u003c\/strong\u003e Set the open percentage for precise flow regulation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePlug Connection:\u003c\/strong\u003e Equipped with an included AC-DC adapter (converts AC 100V–240V to DC 5V) for direct wall outlet power supply.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNormally Closed:\u003c\/strong\u003e Closed when unpowered, opens when energized.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNPT\/G Threading:\u003c\/strong\u003e NPT (National Pipe Taper) and G (BSPP) threading to accommodate diverse global specifications, ensuring a secure seal with \u003ca href=\"https:\/\/ussolid.com\/products\/u-s-solid-10-rolls-0-7-inch-w-x-905-inches-l-teflon-tape-plumbers-tape-yellow-shell-html?_pos=3\u0026amp;_sid=7aa2e2725\u0026amp;_ss=r\" target=\"_blank\"\u003eteflon tape\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eValve Body Material:\u003c\/strong\u003e Constructed from corrosion-resistant brass. Not suitable for drinking water applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePTFE Seal:\u003c\/strong\u003e Superior to NBR and Viton in sealing, temperature, and pressure resistance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFSV\/jfsv-smart-plug-ss.jpg\"\u003e \u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFSV\/jfsv-smart-plug-ss-p.jpg\"\u003e\u003c\/p\u003e\n\u003c!-- Technical Data --\u003e\n\u003ch2 class=\"section-title3\"\u003eTechnical Data\u003c\/h2\u003e\n\u003cdiv class=\"parameters-table-wrapper\"\u003e\n\u003ctable class=\"parameters-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eUSS-MSV00452\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eProduct Name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eSmart Motorized Ball Valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eBore Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eStandard Port\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eLife Expectancy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e80,000-100,000 Cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eStatus Indicator\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eYes\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eFlow Aperture\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e20 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eThread Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eNPT\/G\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eOperating State\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eNormally Closed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eSize\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e3\/4\"\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eWiring Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003ePlug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eValve Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eBrass\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eBall Seal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003ePTFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eOperating Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e8-10 Seconds\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eWorking Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eConverts AC 100V–240V to DC 5V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eMax Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e5W\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eMax Torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e10 N·m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eMedium Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e32℉ to 194℉\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eAmbient Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-4℉ to 113℉\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eMax Medium Pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e145 PSI (1.0 Mpa)\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eCompatible Media\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eWater, air, oil and gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eGross Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1.90 lbs\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003ePackage Dimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e6.30\"x4.72\"x4.13\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eUSB Cable Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2.1 m \/ 6.9 ft\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp class=\"section-description\"\u003e*To view the full table on mobile, please swipe left or right on the screen.\u003c\/p\u003e\n\u003c!-- User Manual --\u003e\n\n\u003ch2 class=\"section-title3\"\u003eCE Certified Quality \u0026amp; Safety\u003c\/h2\u003e\n\u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/CE\/CE.jpg\"\u003e\n\u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/CE\/CE.jpg\"\u003e\n\u003ch2 class=\"section-title\"\u003eUser Manual\u003c\/h2\u003e\n\u003cp class=\"section-description\"\u003eTo learn how to use this product, please refer to the \u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/Instruction%20Manual-U.S.%20Solid%20Smart%20Motorized%20Ball%20Valve2025.pdf\" target=\"_blank\"\u003euser manual\u003c\/a\u003e or watch the \u003ca href=\"https:\/\/youtu.be\/PfpgH29YU-s?list=TLGGw48OMJtyzq8yMTA3MjAyNQ\" target=\"_blank\"\u003etutorial video\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\u003cstrong\u003eNote:\u003c\/strong\u003eThe GIF demonstrates flow control by setting Open Percentage (100% = fully open, 0% = fully closed).\u003c\/p\u003e\n\u003cdiv class=\"instruction-container\"\u003e\n\u003cdiv class=\"img-container\"\u003e\u003cimg alt=\"\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif11.gif\" style=\"width: 100%; height: auto;\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"text-container\"\u003e\u003cimg alt=\"\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif12.gif\" style=\"width: 100%; height: auto;\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- FAQ --\u003e\n\u003ch2 class=\"section-title\"\u003eFAQ\u003c\/h2\u003e\n\u003cp class=\"faq\"\u003e\u003cb\u003eProblem 1: What's the difference between this series and the basic Smart Motorized Ball Valve model?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003eWhile the basic model operates on DC5V via USB, this series includes a plug adapter that converts AC100V-240V to DC5V for direct wall outlet connection.\u003c\/p\u003e\n\u003cp class=\"faq\"\u003e\u003cb\u003eProblem 2: Can the Smart Motorized Ball Valve only be controlled via the app?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\u003cstrong\u003eNo\u003c\/strong\u003e, it also features a manual push-button for local control.\u003c\/p\u003e\n\u003cp class=\"faq\"\u003e\u003cb\u003eProblem 3: This smart ball valve is marked as normally closed – can its power-off passage state be modified via the app?\u003c\/b\u003e\u003c\/p\u003e\n\u003cdiv class=\"instruction-container-faq\"\u003e\n\u003cdiv class=\"img-container-faq\"\u003e\u003cimg alt=\"\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFSV\/jfsv-smart-plug-off.jpg\" style=\"width: 100%; height: auto;\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"text-container-faq\"\u003e\n\u003cp class=\"section-title\"\u003eTap “Settings” to set\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003eThis smart ball valve is factory default set to a normally closed state (valve passage closes automatically when power is lost), and you can freely adjust its power-off working state according to your actual usage needs through the dedicated mobile app.\u003c\/p\u003e\n\u003cp class=\"section-title\"\u003eThree states\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003eSelect the specific power-off state you need for the valve, and the setting will be automatically saved immediately once you make your selection, no additional save operation is required.\u003c\/p\u003e\n\u003cul class=\"section-description2\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eOff:\u003c\/strong\u003e The valve passage stays closed when power is lost (consistent with the default setting).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOn:\u003c\/strong\u003e The valve passage remains open when power is lost.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMemory:\u003c\/strong\u003e The valve passage maintains its last working position before the power failure.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp class=\"faq\"\u003e\u003cb\u003eProblem 4: What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n\u003cul class=\"section-description2\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eFull Port:\u003c\/strong\u003e Matches pipe diameter, minimal flow restriction, ideal for high flow and low pressure drop.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard Port:\u003c\/strong\u003e Smaller than pipe diameter, higher resistance, suitable for general flow and pressure needs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"faq\"\u003e\u003cb\u003eProblem 5: Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\u003cstrong\u003eNo.\u003c\/strong\u003e This valve is made of brass and is not suitable for drinking water applications.\u003c\/p\u003e","brand":"U.S. Solid","offers":[{"title":"NPT","offer_id":47129060704511,"sku":"JFMSV00452","price":97.99,"currency_code":"USD","in_stock":true},{"title":"G","offer_id":47158044786943,"sku":"JFMSV00452-G","price":93.99,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/1_68b394dc-894f-4181-9855-70dea288a69e.jpg?v=1755586745"},{"product_id":"wifi-1-brass-remote-control-motorized-ball-valve-with-power-off-memory-ac-100-240v-plug-adapter-with-dc-5v-output-manual-switch","title":"WiFi 1\" Brass Remote Control Motorized Ball Valve with Power-Off Memory, AC 100-240V Plug Adapter with DC 5V Output, Manual Switch","description":"\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e \u003cmeta content=\"width=device-width, initial-scale=1.0\" name=\"viewport\"\u003e\u003c\/p\u003e\n\u003cstyle\u003e\n        \n        .desktop-img {\n            display: block;\n        }\n        .mobile-img {\n            display: none;\n        } \n        \n        .section-title {\n            font-size: 22px;\n            line-height: 22px;\n            font-weight: bold;\n            margin: 15px 0 5px; \n            font-family: Arial;\n        }\n        \n        .section-title2 {\n            font-size: 22px;\n            line-height: 22px;\n            font-weight: bold;\n            margin: 15px 0 3px; \n            font-family: Arial;\n        }\n       \n        .section-title3 {\n            font-size: 22px;\n            line-height: 22px;\n            font-weight: bold;\n            margin: 15px 0 10px; \n            font-family: Arial;\n        }\n\n        \n        .section-description {\n            font-size: 16px;\n            line-height: 26px;\n            margin-top: 0px;\n            margin-bottom: 5px; \n            font-family: Arial;\n        }\n      \n        .faq {\n            font-size: 16px; \n            margin: 0; \n            line-height: 26px; \n            background-color: #f2f2f2; \n            padding: 5px;\n        }\n        \n        .section-description2 {\n            font-size: 16px;\n            line-height: 26px;\n            margin: 0px; \n            font-family: Arial;\n        }\n        \n.parameters-table-wrapper {\n    overflow-x: auto; \n    -webkit-overflow-scrolling: touch; \n    margin-top: 0px;\n}\n\n\n.parameters-table {\n    width: 100%;\n    min-width: 1000px;\n    border-collapse: collapse;\n    margin-top: 0px;\n}\n\n.parameters-table th, .parameters-table td {\n    border-top: 1.2px solid #a6a6a6; \n    border-bottom: 1.2px solid #a6a6a6;  \n    border-left: none;  \n    border-right: none;  \n    padding: 5px 2px;\n    text-align: left;\n    font-size: 16px;\n    line-height: 16px;\n}\n\n.parameters-table th {\n    background-color: #f2f2f2;\n    color: #2c2c2c;\n    font-weight: bold;\n}\n\n\n.parameters-table .bg-gray {\n    background-color: #f2f2f2;  \n}\n\n\n.options-table-wrapper {\n    overflow-x: auto; \n    -webkit-overflow-scrolling: touch; \n    margin-top: 0px;\n}\n\n.options-table {\n    width: 100%;\n    min-width: 1000px; \n    border-collapse: collapse;\n    margin-top: 0px;\n    box-shadow: 0 6px 25px rgba(0, 0, 0, 0.1); \n}\n\n.options-table th, .options-table td {\n    border: 2px solid #000;  \n    padding: 5px 2px;  \n    text-align: center;\n    font-size: 16px;\n    line-height: 16px;\n}\n\n.options-table th {\n    background-color: #f2f2f2;\n    color: #2c2c2c;\n    font-weight: bold;\n}\n\n\n.parameters-table2 {\n    width: 100%;\n    min-width: 1000px; \n    border-collapse: collapse;\n    margin-top: 0px;\n}\n\n.parameters-table2 th, .parameters-table2 td {\n    border-top: 1.2px solid #a6a6a6;  \n    border-bottom: 1.2px solid #a6a6a6; \n    border-left: none;  \n    border-right: none; \n    padding: 5px 2px;\n    text-align: center;\n    font-size: 16px;\n    line-height: 16px;\n}\n\n.parameters-table2 th {\n    background-color: #f2f2f2;\n    color: #2c2c2c;\n    font-weight: bold;\n}\n\n\n.parameters-table2 .bg-gray {\n    background-color: #f2f2f2;  \n}\n\n\n.options-table-wrapper2 {\n    overflow-x: auto; \n    -webkit-overflow-scrolling: touch; \n    margin-top: 0px;\n}\n\n        .instruction-container {\n             display: flex;\n             justify-content: space-between;\n             align-items: flex-start;\n             gap: 10px; \/* Adds space between the video and the text *\/\n             margin-bottom: 0px; \/* Adds some space below the section *\/\n        }\n\n      \n        .img-container {\n              width: 50%; \n             display: flex;\n             justify-content: center; \n        }\n\n      \n        .text-container {\n               width: 50%; \n             font-size: 16px;\n             font-family: Arial;\n             \n         }\n\n         .instruction-container2 {\n             display: flex;\n             justify-content: space-between;\n             align-items: flex-start;\n             gap: 10px; \/* Adds space between the video and the text *\/\n             margin-bottom: 0px; \/* Adds some space below the section *\/\n        }\n\n      \n        .img-container2 {\n             width: 50%; \n             display: flex;\n             justify-content: center; \n        }\n\n      \n        .text-container2 {\n             width: 50%; \n            display: flex;\n             justify-content: center;\n         }\n\n\/* FAQ专属 图片+文字容器 40%+60%占比 - 不影响其他instruction-container *\/\n.instruction-container-faq {\n    display: flex;\n    justify-content: space-between;\n    align-items: flex-start;\n    gap: 10px;\n    margin-bottom: 0px;\n}\n.img-container-faq {\n    width: 35%; \/* FAQ图片占40% *\/\n    display: flex;\n    justify-content: center;\n}\n.text-container-faq {\n    width: 65%; \/* FAQ文字占60% *\/\n    font-size: 16px;\n    font-family: Arial;\n}\n\/* FAQ专属 移动端适配 - 自动上下排列 *\/\n@media (max-width: 768px) {\n    .instruction-container-faq {\n        flex-direction: column;\n        align-items: center;\n    }\n    .img-container-faq, .text-container-faq {\n        width: 100%;\n        margin-bottom: 0px;\n    }\n}\n\n@media (max-width: 768px) {\n    .parameters-table th, .parameters-table td {\n        font-size: 14px; \n        padding: 8px 4px; \n    }\n\n   \n    .options-table th, .options-table td {\n        font-size: 14px; \n        padding: 8px 4px;\n    }\n\n    .parameters-table-wrapper {\n        overflow-x: auto;\n    }\n    .parameters-table2 th, .parameters-table2 td {\n        font-size: 14px; \n        padding: 8px 4px; \n    }\n    .parameters-table-wrapper2 {\n        overflow-x: auto;\n    }\n    .desktop-img {\n                display: none;\n            }\n            .mobile-img {\n                display: block; \n            }\n    .instruction-container {\n                flex-direction: column; \n                align-items: center;\n            }\n\n            .img-container, .text-container {\n                width: 100%; \/* Both take full width *\/\n                margin-bottom: 0px; \n            }\n            .instruction-container2 {\n                flex-direction: column; \n                align-items: center;\n            }\n\n            .img-container2, .text-container2 {\n                width: 100%; \/* Both take full width *\/\n                margin-bottom: 0px; \n            }\n    \n}\n\n@media (max-width: 480px) {\n    .parameters-table th, .parameters-table td {\n        font-size: 12px; \n        padding: 6px 3px; \n    }\n\n    \n    .options-table th, .options-table td {\n        font-size: 12px; \n    }\n\n    .parameters-table-wrapper {\n        overflow-x: auto;\n    }\n    .parameters-table2 th, .parameters-table2 td {\n        font-size: 12px; \n        padding: 6px 3px; \n    }\n    .parameters-table-wrapper2 {\n        overflow-x: auto;\n    }\n    .desktop-img {\n                display: none; \n            }\n            .mobile-img {\n                display: block; \n            }\n    .instruction-container {\n                flex-direction: column; \n            }\n            .instruction-container2 {\n                flex-direction: column; \n            }\n    \n}\n    \u003c\/style\u003e\n\u003c!-- background --\u003e\n\u003cp\u003e\u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/jfmsv-WiFi-plug-a.jpg\"\u003e \u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/jfmsv-WiFi-plug-a-p.jpg\"\u003e\u003c\/p\u003e\n\u003c!-- Introduction --\u003e\n\u003cdiv\u003e\n\u003ch2 class=\"section-title\"\u003eIntroduction\u003c\/h2\u003e\n\u003cp class=\"section-description\"\u003eThe U.S. Solid Smart Motorized Ball Valve is a cutting-edge motorized ball valve with built-in smart control technology. Easily control the valve using your mobile device via Wi-Fi, with no complicated installation required. Simply download the app, connect to Wi-Fi, and remotely open or close the valve with a few taps. Enjoy unmatched convenience and ease of use compared to traditional valves. Perfect for controlling water, gas, or other fluids with reliable and accurate control every time.\u003cbr\u003eCompared to the basic model of smart motorized ball valve (powered by DC 5V via USB), this series comes with a plug-in AC-DC adapter that converts AC 100V-240V to DC 5V, enabling direct power supply from standard household AC outlets.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- Applications--\u003e\n\u003ch2 class=\"section-title2\"\u003eApplications\u003c\/h2\u003e\n\u003cp\u003e\u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFSV\/JFSV-smart-plug-a.jpg\"\u003e \u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFSV\/JFSV-a-p.jpg\"\u003e\u003c\/p\u003e\n\u003c!-- Smart Control--\u003e\n\u003ch2 class=\"section-title2\"\u003eSmart Control\u003c\/h2\u003e\n\u003cp class=\"section-description\"\u003eThe smart motorized ball valve features a smart-control function, providing you with the convenience of controlling your valve using your cellphone. Furthermore, once the valve is connected to your WiFi, you can remotely control the valve even when you are away from home.\u003cbr\u003eThis feature allows for seamless and convenient operation of the valve from anywhere at any time.In addition to its smart control capabilities, the motorized ball valve is also equipped with a manual switch, providing an added layer of assurance and peace of mind.\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFSV\/JFSV-smart-plug.jpg\"\u003e \u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFSV\/JFSV-smart-plug-p-1.jpg\"\u003e \u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFSV\/JFSV-smart-plug-p-2.jpg\"\u003e\u003c\/p\u003e\n\u003c!-- Features --\u003e\n\u003cdiv\u003e\n\u003ch2 class=\"section-title\"\u003eFeatures\u003c\/h2\u003e\n\u003cul class=\"section-description2\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eOpen Percentage:\u003c\/strong\u003e Set the open percentage for precise flow regulation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePlug Connection:\u003c\/strong\u003e Equipped with an included AC-DC adapter (converts AC 100V–240V to DC 5V) for direct wall outlet power supply.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNormally Closed:\u003c\/strong\u003e Closed when unpowered, opens when energized.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNPT\/G Threading:\u003c\/strong\u003e NPT (National Pipe Taper) and G (BSPP) threading to accommodate diverse global specifications, ensuring a secure seal with \u003ca href=\"https:\/\/ussolid.com\/products\/u-s-solid-10-rolls-0-7-inch-w-x-905-inches-l-teflon-tape-plumbers-tape-yellow-shell-html?_pos=3\u0026amp;_sid=7aa2e2725\u0026amp;_ss=r\" target=\"_blank\"\u003eteflon tape\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eValve Body Material:\u003c\/strong\u003e Constructed from corrosion-resistant brass. Not suitable for drinking water applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePTFE Seal:\u003c\/strong\u003e Superior to NBR and Viton in sealing, temperature, and pressure resistance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFSV\/jfsv-smart-plug-ss.jpg\"\u003e \u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFSV\/jfsv-smart-plug-ss-p.jpg\"\u003e\u003c\/p\u003e\n\u003c!-- Technical Data --\u003e\n\u003ch2 class=\"section-title3\"\u003eTechnical Data\u003c\/h2\u003e\n\u003cdiv class=\"parameters-table-wrapper\"\u003e\n\u003ctable class=\"parameters-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eUSS-MSV00453\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eProduct Name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eSmart Motorized Ball Valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eBore Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eStandard Port\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eLife Expectancy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e80,000-100,000 Cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eStatus Indicator\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eYes\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eFlow Aperture\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e23.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eThread Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eNPT\/G\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eOperating State\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eNormally Closed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eSize\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1\"\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eWiring Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003ePlug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eValve Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eBrass\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eBall Seal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003ePTFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eOperating Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e8-10 Seconds\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eWorking Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eConverts AC 100V–240V to DC 5V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eMax Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e5W\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eMax Torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e10 N·m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eMedium Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e32℉ to 194℉\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eAmbient Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-4℉ to 113℉\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eMax Medium Pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e145 PSI (1.0 Mpa)\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eCompatible Media\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eWater, air, oil and gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eGross Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2.20 lbs\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003ePackage Dimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e6.30\"x4.72\"x3.94\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eUSB Cable Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2.1 m \/ 6.9 ft\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp class=\"section-description\"\u003e*To view the full table on mobile, please swipe left or right on the screen.\u003c\/p\u003e\n\u003c!-- User Manual --\u003e\n\n\u003ch2 class=\"section-title3\"\u003eCE Certified Quality \u0026amp; Safety\u003c\/h2\u003e\n\u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/CE\/CE.jpg\"\u003e\n\u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/CE\/CE.jpg\"\u003e\n\u003ch2 class=\"section-title\"\u003eUser Manual\u003c\/h2\u003e\n\u003cp class=\"section-description\"\u003eTo learn how to use this product, please refer to the \u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/Instruction%20Manual-U.S.%20Solid%20Smart%20Motorized%20Ball%20Valve2025.pdf\" target=\"_blank\"\u003euser manual\u003c\/a\u003e or watch the \u003ca href=\"https:\/\/youtu.be\/PfpgH29YU-s?list=TLGGw48OMJtyzq8yMTA3MjAyNQ\" target=\"_blank\"\u003etutorial video\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\u003cstrong\u003eNote:\u003c\/strong\u003eThe GIF demonstrates flow control by setting Open Percentage (100% = fully open, 0% = fully closed).\u003c\/p\u003e\n\u003cdiv class=\"instruction-container\"\u003e\n\u003cdiv class=\"img-container\"\u003e\u003cimg alt=\"\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif11.gif\" style=\"width: 100%; height: auto;\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"text-container\"\u003e\u003cimg alt=\"\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif12.gif\" style=\"width: 100%; height: auto;\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- FAQ --\u003e\n\u003ch2 class=\"section-title\"\u003eFAQ\u003c\/h2\u003e\n\u003cp class=\"faq\"\u003e\u003cb\u003eProblem 1: What's the difference between this series and the basic Smart Motorized Ball Valve model?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003eWhile the basic model operates on DC5V via USB, this series includes a plug adapter that converts AC100V-240V to DC5V for direct wall outlet connection.\u003c\/p\u003e\n\u003cp class=\"faq\"\u003e\u003cb\u003eProblem 2: Can the Smart Motorized Ball Valve only be controlled via the app?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\u003cstrong\u003eNo\u003c\/strong\u003e, it also features a manual push-button for local control.\u003c\/p\u003e\n\u003cp class=\"faq\"\u003e\u003cb\u003eProblem 3: This smart ball valve is marked as normally closed – can its power-off passage state be modified via the app?\u003c\/b\u003e\u003c\/p\u003e\n\u003cdiv class=\"instruction-container-faq\"\u003e\n\u003cdiv class=\"img-container-faq\"\u003e\u003cimg alt=\"\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFSV\/jfsv-smart-plug-off.jpg\" style=\"width: 100%; height: auto;\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"text-container-faq\"\u003e\n\u003cp class=\"section-title\"\u003eTap “Settings” to set\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003eThis smart ball valve is factory default set to a normally closed state (valve passage closes automatically when power is lost), and you can freely adjust its power-off working state according to your actual usage needs through the dedicated mobile app.\u003c\/p\u003e\n\u003cp class=\"section-title\"\u003eThree states\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003eSelect the specific power-off state you need for the valve, and the setting will be automatically saved immediately once you make your selection, no additional save operation is required.\u003c\/p\u003e\n\u003cul class=\"section-description2\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eOff:\u003c\/strong\u003e The valve passage stays closed when power is lost (consistent with the default setting).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOn:\u003c\/strong\u003e The valve passage remains open when power is lost.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMemory:\u003c\/strong\u003e The valve passage maintains its last working position before the power failure.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp class=\"faq\"\u003e\u003cb\u003eProblem 4: What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n\u003cul class=\"section-description2\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eFull Port:\u003c\/strong\u003e Matches pipe diameter, minimal flow restriction, ideal for high flow and low pressure drop.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard Port:\u003c\/strong\u003e Smaller than pipe diameter, higher resistance, suitable for general flow and pressure needs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"faq\"\u003e\u003cb\u003eProblem 5: Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\u003cstrong\u003eNo.\u003c\/strong\u003e This valve is made of brass and is not suitable for drinking water applications.\u003c\/p\u003e","brand":"U.S. Solid","offers":[{"title":"NPT","offer_id":47129062670591,"sku":"JFMSV00453","price":100.99,"currency_code":"USD","in_stock":true},{"title":"G","offer_id":47158052749567,"sku":"JFMSV00453-G","price":97.99,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/2_ca14e489-de30-400d-9845-ef84fc5ce37c.jpg?v=1755587044"},{"product_id":"wifi-12-stainless-steel-remote-control-motorized-ball-valve-with-power-off-memory-ac-100-240v-plug-adapter-with-dc-5v-output-manual-switch","title":"WiFi 1\/2\" Stainless Steel Remote Control Motorized Ball Valve with Power-Off Memory, AC 100-240V Plug Adapter with DC 5V Output, Manual Switch","description":"\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e \u003cmeta content=\"width=device-width, initial-scale=1.0\" name=\"viewport\"\u003e\u003c\/p\u003e\n\u003cstyle\u003e\n        \n        .desktop-img {\n            display: block;\n        }\n        .mobile-img {\n            display: none;\n        } \n        \n        .section-title {\n            font-size: 22px;\n            line-height: 22px;\n            font-weight: bold;\n            margin: 15px 0 5px; \n            font-family: Arial;\n        }\n        \n        .section-title2 {\n            font-size: 22px;\n            line-height: 22px;\n            font-weight: bold;\n            margin: 15px 0 3px; \n            font-family: Arial;\n        }\n       \n        .section-title3 {\n            font-size: 22px;\n            line-height: 22px;\n            font-weight: bold;\n            margin: 15px 0 10px; \n            font-family: Arial;\n        }\n\n        \n        .section-description {\n            font-size: 16px;\n            line-height: 26px;\n            margin-top: 0px;\n            margin-bottom: 5px; \n            font-family: Arial;\n        }\n      \n        .faq {\n            font-size: 16px; \n            margin: 0; \n            line-height: 26px; \n            background-color: #f2f2f2; \n            padding: 5px;\n        }\n        \n        .section-description2 {\n            font-size: 16px;\n            line-height: 26px;\n            margin: 0px; \n            font-family: Arial;\n        }\n        \n.parameters-table-wrapper {\n    overflow-x: auto; \n    -webkit-overflow-scrolling: touch; \n    margin-top: 0px;\n}\n\n\n.parameters-table {\n    width: 100%;\n    min-width: 1000px;\n    border-collapse: collapse;\n    margin-top: 0px;\n}\n\n.parameters-table th, .parameters-table td {\n    border-top: 1.2px solid #a6a6a6; \n    border-bottom: 1.2px solid #a6a6a6;  \n    border-left: none;  \n    border-right: none;  \n    padding: 5px 2px;\n    text-align: left;\n    font-size: 16px;\n    line-height: 16px;\n}\n\n.parameters-table th {\n    background-color: #f2f2f2;\n    color: #2c2c2c;\n    font-weight: bold;\n}\n\n\n.parameters-table .bg-gray {\n    background-color: #f2f2f2;  \n}\n\n\n.options-table-wrapper {\n    overflow-x: auto; \n    -webkit-overflow-scrolling: touch; \n    margin-top: 0px;\n}\n\n.options-table {\n    width: 100%;\n    min-width: 1000px; \n    border-collapse: collapse;\n    margin-top: 0px;\n    box-shadow: 0 6px 25px rgba(0, 0, 0, 0.1); \n}\n\n.options-table th, .options-table td {\n    border: 2px solid #000;  \n    padding: 5px 2px;  \n    text-align: center;\n    font-size: 16px;\n    line-height: 16px;\n}\n\n.options-table th {\n    background-color: #f2f2f2;\n    color: #2c2c2c;\n    font-weight: bold;\n}\n\n\n.parameters-table2 {\n    width: 100%;\n    min-width: 1000px; \n    border-collapse: collapse;\n    margin-top: 0px;\n}\n\n.parameters-table2 th, .parameters-table2 td {\n    border-top: 1.2px solid #a6a6a6;  \n    border-bottom: 1.2px solid #a6a6a6; \n    border-left: none;  \n    border-right: none; \n    padding: 5px 2px;\n    text-align: center;\n    font-size: 16px;\n    line-height: 16px;\n}\n\n.parameters-table2 th {\n    background-color: #f2f2f2;\n    color: #2c2c2c;\n    font-weight: bold;\n}\n\n\n.parameters-table2 .bg-gray {\n    background-color: #f2f2f2;  \n}\n\n\n.options-table-wrapper2 {\n    overflow-x: auto; \n    -webkit-overflow-scrolling: touch; \n    margin-top: 0px;\n}\n\n        .instruction-container {\n             display: flex;\n             justify-content: space-between;\n             align-items: flex-start;\n             gap: 10px; \/* Adds space between the video and the text *\/\n             margin-bottom: 0px; \/* Adds some space below the section *\/\n        }\n\n      \n        .img-container {\n              width: 50%; \n             display: flex;\n             justify-content: center; \n        }\n\n      \n        .text-container {\n               width: 50%; \n             font-size: 16px;\n             font-family: Arial;\n             \n         }\n\n         .instruction-container2 {\n             display: flex;\n             justify-content: space-between;\n             align-items: flex-start;\n             gap: 10px; \/* Adds space between the video and the text *\/\n             margin-bottom: 0px; \/* Adds some space below the section *\/\n        }\n\n      \n        .img-container2 {\n             width: 50%; \n             display: flex;\n             justify-content: center; \n        }\n\n      \n        .text-container2 {\n             width: 50%; \n            display: flex;\n             justify-content: center;\n         }\n\n\/* FAQ专属 图片+文字容器 40%+60%占比 - 不影响其他instruction-container *\/\n.instruction-container-faq {\n    display: flex;\n    justify-content: space-between;\n    align-items: flex-start;\n    gap: 10px;\n    margin-bottom: 0px;\n}\n.img-container-faq {\n    width: 35%; \/* FAQ图片占40% *\/\n    display: flex;\n    justify-content: center;\n}\n.text-container-faq {\n    width: 65%; \/* FAQ文字占60% *\/\n    font-size: 16px;\n    font-family: Arial;\n}\n\/* FAQ专属 移动端适配 - 自动上下排列 *\/\n@media (max-width: 768px) {\n    .instruction-container-faq {\n        flex-direction: column;\n        align-items: center;\n    }\n    .img-container-faq, .text-container-faq {\n        width: 100%;\n        margin-bottom: 0px;\n    }\n}\n\n@media (max-width: 768px) {\n    .parameters-table th, .parameters-table td {\n        font-size: 14px; \n        padding: 8px 4px; \n    }\n\n   \n    .options-table th, .options-table td {\n        font-size: 14px; \n        padding: 8px 4px;\n    }\n\n    .parameters-table-wrapper {\n        overflow-x: auto;\n    }\n    .parameters-table2 th, .parameters-table2 td {\n        font-size: 14px; \n        padding: 8px 4px; \n    }\n    .parameters-table-wrapper2 {\n        overflow-x: auto;\n    }\n    .desktop-img {\n                display: none;\n            }\n            .mobile-img {\n                display: block; \n            }\n    .instruction-container {\n                flex-direction: column; \n                align-items: center;\n            }\n\n            .img-container, .text-container {\n                width: 100%; \/* Both take full width *\/\n                margin-bottom: 0px; \n            }\n            .instruction-container2 {\n                flex-direction: column; \n                align-items: center;\n            }\n\n            .img-container2, .text-container2 {\n                width: 100%; \/* Both take full width *\/\n                margin-bottom: 0px; \n            }\n    \n}\n\n@media (max-width: 480px) {\n    .parameters-table th, .parameters-table td {\n        font-size: 12px; \n        padding: 6px 3px; \n    }\n\n    \n    .options-table th, .options-table td {\n        font-size: 12px; \n    }\n\n    .parameters-table-wrapper {\n        overflow-x: auto;\n    }\n    .parameters-table2 th, .parameters-table2 td {\n        font-size: 12px; \n        padding: 6px 3px; \n    }\n    .parameters-table-wrapper2 {\n        overflow-x: auto;\n    }\n    .desktop-img {\n                display: none; \n            }\n            .mobile-img {\n                display: block; \n            }\n    .instruction-container {\n                flex-direction: column; \n            }\n            .instruction-container2 {\n                flex-direction: column; \n            }\n    \n}\n    \u003c\/style\u003e\n\u003c!-- background --\u003e\n\u003cp\u003e\u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/jfmsv-WiFi-plug-a.jpg\"\u003e \u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/jfmsv-WiFi-plug-a-p.jpg\"\u003e\u003c\/p\u003e\n\u003c!-- Introduction --\u003e\n\u003cdiv\u003e\n\u003ch2 class=\"section-title\"\u003eIntroduction\u003c\/h2\u003e\n\u003cp class=\"section-description\"\u003eThe U.S. Solid Smart Motorized Ball Valve is a cutting-edge motorized ball valve with built-in smart control technology. Easily control the valve using your mobile device via Wi-Fi, with no complicated installation required. Simply download the app, connect to Wi-Fi, and remotely open or close the valve with a few taps. Enjoy unmatched convenience and ease of use compared to traditional valves. Perfect for controlling water, gas, or other fluids with reliable and accurate control every time.\u003cbr\u003eCompared to the basic model of smart motorized ball valve (powered by DC 5V via USB), this series comes with a plug-in AC-DC adapter that converts AC 100V-240V to DC 5V, enabling direct power supply from standard household AC outlets.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- Applications--\u003e\n\u003ch2 class=\"section-title2\"\u003eApplications\u003c\/h2\u003e\n\u003cp\u003e\u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFSV\/JFSV-smart-plug-a.jpg\"\u003e \u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFSV\/JFSV-a-p.jpg\"\u003e\u003c\/p\u003e\n\u003c!-- Smart Control--\u003e\n\u003ch2 class=\"section-title2\"\u003eSmart Control\u003c\/h2\u003e\n\u003cp class=\"section-description\"\u003eThe smart motorized ball valve features a smart-control function, providing you with the convenience of controlling your valve using your cellphone. Furthermore, once the valve is connected to your WiFi, you can remotely control the valve even when you are away from home.\u003cbr\u003eThis feature allows for seamless and convenient operation of the valve from anywhere at any time.In addition to its smart control capabilities, the motorized ball valve is also equipped with a manual switch, providing an added layer of assurance and peace of mind.\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFSV\/JFSV-smart-plug.jpg\"\u003e \u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFSV\/JFSV-smart-plug-p-1.jpg\"\u003e \u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFSV\/JFSV-smart-plug-p-2.jpg\"\u003e\u003c\/p\u003e\n\u003c!-- Features --\u003e\n\u003cdiv\u003e\n\u003ch2 class=\"section-title\"\u003eFeatures\u003c\/h2\u003e\n\u003cul class=\"section-description2\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eOpen Percentage:\u003c\/strong\u003e Set the open percentage for precise flow regulation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePlug Connection:\u003c\/strong\u003e Equipped with an included AC-DC adapter (converts AC 100V–240V to DC 5V) for direct wall outlet power supply.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFull Port:\u003c\/strong\u003e Maximum flow efficiency, zero restriction.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNormally Closed:\u003c\/strong\u003e Closed when unpowered, opens when energized.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNPT\/G Threading:\u003c\/strong\u003e NPT (National Pipe Taper) and G (BSPP) threading to accommodate diverse global specifications, ensuring a secure seal with \u003ca href=\"https:\/\/ussolid.com\/products\/u-s-solid-10-rolls-0-7-inch-w-x-905-inches-l-teflon-tape-plumbers-tape-yellow-shell-html?_pos=3\u0026amp;_sid=7aa2e2725\u0026amp;_ss=r\" target=\"_blank\"\u003eteflon tape\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eValve Body Material:\u003c\/strong\u003e Constructed from corrosion-resistant stainless steel and is NSF\/ANSI\/CAN 61 certified. Suitable for drinking water applications (compliant with standards).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePTFE Seal:\u003c\/strong\u003e Superior to NBR and Viton in sealing, temperature, and pressure resistance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFSV\/jfsv-smart-plug-ss.jpg\"\u003e \u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFSV\/jfsv-smart-plug-ss-p.jpg\"\u003e\u003c\/p\u003e\n\u003c!-- Technical Data --\u003e\n\u003ch2 class=\"section-title3\"\u003eTechnical Data\u003c\/h2\u003e\n\u003cdiv class=\"parameters-table-wrapper\"\u003e\n\u003ctable class=\"parameters-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eUSS-MSV00454\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eProduct Name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eSmart Motorized Ball Valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eBore Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eFull Port\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eLife Expectancy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e80,000-100,000 Cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eStatus Indicator\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eYes\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eFlow Aperture\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e15 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eThread Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eNPT\/G\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eOperating State\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eNormally Closed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eSize\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1\/2\"\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eWiring Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003ePlug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eValve Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eStainless Steel\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eBall Seal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003ePTFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eOperating Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e8-10 Seconds\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eWorking Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eConverts AC 100V–240V to DC 5V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eMax Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e5W\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eMax Torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e10 N·m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eMedium Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e32℉ to 194℉\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eAmbient Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-4℉ to 113℉\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eMax Medium Pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e145 PSI (1.0 Mpa)\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eCompatible Media\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eWater, air, oil and gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eGross Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1.83 lbs\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003ePackage Dimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e6.30\"x4.72\"x4.13\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eUSB Cable Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2.1 m \/ 6.9 ft\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp class=\"section-description\"\u003e*To view the full table on mobile, please swipe left or right on the screen.\u003c\/p\u003e\n\u003c!-- User Manual --\u003e\n\n\u003ch2 class=\"section-title3\"\u003eCE Certified Quality \u0026amp; Safety\u003c\/h2\u003e\n\u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/CE\/CE.jpg\"\u003e\n\u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/CE\/CE.jpg\"\u003e\n\u003ch2 class=\"section-title\"\u003eUser Manual\u003c\/h2\u003e\n\u003cp class=\"section-description\"\u003eTo learn how to use this product, please refer to the \u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/Instruction%20Manual-U.S.%20Solid%20Smart%20Motorized%20Ball%20Valve2025.pdf\" target=\"_blank\"\u003euser manual\u003c\/a\u003e or watch the \u003ca href=\"https:\/\/youtu.be\/PfpgH29YU-s?list=TLGGw48OMJtyzq8yMTA3MjAyNQ\" target=\"_blank\"\u003etutorial video\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\u003cstrong\u003eNote:\u003c\/strong\u003eThe GIF demonstrates flow control by setting Open Percentage (100% = fully open, 0% = fully closed).\u003c\/p\u003e\n\u003cdiv class=\"instruction-container\"\u003e\n\u003cdiv class=\"img-container\"\u003e\u003cimg alt=\"\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif11.gif\" style=\"width: 100%; height: auto;\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"text-container\"\u003e\u003cimg alt=\"\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif12.gif\" style=\"width: 100%; height: auto;\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- FAQ --\u003e\n\u003ch2 class=\"section-title\"\u003eFAQ\u003c\/h2\u003e\n\u003cp class=\"faq\"\u003e\u003cb\u003eProblem 1: What's the difference between this series and the basic Smart Motorized Ball Valve model?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003eWhile the basic model operates on DC5V via USB, this series includes a plug adapter that converts AC100V-240V to DC5V for direct wall outlet connection.\u003c\/p\u003e\n\u003cp class=\"faq\"\u003e\u003cb\u003eProblem 2: Can the Smart Motorized Ball Valve only be controlled via the app?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\u003cstrong\u003eNo\u003c\/strong\u003e, it also features a manual push-button for local control.\u003c\/p\u003e\n\u003cp class=\"faq\"\u003e\u003cb\u003eProblem 3: This smart ball valve is marked as normally closed – can its power-off passage state be modified via the app?\u003c\/b\u003e\u003c\/p\u003e\n\u003cdiv class=\"instruction-container-faq\"\u003e\n\u003cdiv class=\"img-container-faq\"\u003e\u003cimg alt=\"\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFSV\/jfsv-smart-plug-off.jpg\" style=\"width: 100%; height: auto;\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"text-container-faq\"\u003e\n\u003cp class=\"section-title\"\u003eTap “Settings” to set\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003eThis smart ball valve is factory default set to a normally closed state (valve passage closes automatically when power is lost), and you can freely adjust its power-off working state according to your actual usage needs through the dedicated mobile app.\u003c\/p\u003e\n\u003cp class=\"section-title\"\u003eThree states\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003eSelect the specific power-off state you need for the valve, and the setting will be automatically saved immediately once you make your selection, no additional save operation is required.\u003c\/p\u003e\n\u003cul class=\"section-description2\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eOff:\u003c\/strong\u003e The valve passage stays closed when power is lost (consistent with the default setting).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOn:\u003c\/strong\u003e The valve passage remains open when power is lost.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMemory:\u003c\/strong\u003e The valve passage maintains its last working position before the power failure.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp class=\"faq\"\u003e\u003cb\u003eProblem 4: What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n\u003cul class=\"section-description2\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eFull Port:\u003c\/strong\u003e Matches pipe diameter, minimal flow restriction, ideal for high flow and low pressure drop.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard Port:\u003c\/strong\u003e Smaller than pipe diameter, higher resistance, suitable for general flow and pressure needs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"faq\"\u003e\u003cb\u003eProblem 5: Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\u003cstrong\u003eYes.\u003c\/strong\u003e This valve is made of food-grade stainless steel, meeting drinking water standards and is NSF\/ANSI\/CAN 61 certified. It is safe for potable water with no lead risk (unlike brass valves).\u003c\/p\u003e","brand":"U.S. Solid","offers":[{"title":"NPT","offer_id":47129063424255,"sku":"JFMSV00454","price":101.09,"currency_code":"USD","in_stock":true},{"title":"G","offer_id":47158068543743,"sku":"JFMSV00454-G","price":97.99,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/2_e90fe5e9-5591-4c94-87fb-d7c9e56ab236.jpg?v=1755587465"},{"product_id":"wifi-34-stainless-steel-remote-control-motorized-ball-valve-with-power-off-memory-ac-100-240v-plug-adapter-with-dc-5v-output-manual-switch","title":"WiFi 3\/4\" Stainless Steel Remote Control Motorized Ball Valve with Power-Off Memory, AC 100-240V Plug Adapter with DC 5V Output, Manual Switch","description":"\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e \u003cmeta content=\"width=device-width, initial-scale=1.0\" name=\"viewport\"\u003e\u003c\/p\u003e\n\u003cstyle\u003e\n        \n        .desktop-img {\n            display: block;\n        }\n        .mobile-img {\n            display: none;\n        } \n        \n        .section-title {\n            font-size: 22px;\n            line-height: 22px;\n            font-weight: bold;\n            margin: 15px 0 5px; \n            font-family: Arial;\n        }\n        \n        .section-title2 {\n            font-size: 22px;\n            line-height: 22px;\n            font-weight: bold;\n            margin: 15px 0 3px; \n            font-family: Arial;\n        }\n       \n        .section-title3 {\n            font-size: 22px;\n            line-height: 22px;\n            font-weight: bold;\n            margin: 15px 0 10px; \n            font-family: Arial;\n        }\n\n        \n        .section-description {\n            font-size: 16px;\n            line-height: 26px;\n            margin-top: 0px;\n            margin-bottom: 5px; \n            font-family: Arial;\n        }\n      \n        .faq {\n            font-size: 16px; \n            margin: 0; \n            line-height: 26px; \n            background-color: #f2f2f2; \n            padding: 5px;\n        }\n        \n        .section-description2 {\n            font-size: 16px;\n            line-height: 26px;\n            margin: 0px; \n            font-family: Arial;\n        }\n        \n.parameters-table-wrapper {\n    overflow-x: auto; \n    -webkit-overflow-scrolling: touch; \n    margin-top: 0px;\n}\n\n\n.parameters-table {\n    width: 100%;\n    min-width: 1000px;\n    border-collapse: collapse;\n    margin-top: 0px;\n}\n\n.parameters-table th, .parameters-table td {\n    border-top: 1.2px solid #a6a6a6; \n    border-bottom: 1.2px solid #a6a6a6;  \n    border-left: none;  \n    border-right: none;  \n    padding: 5px 2px;\n    text-align: left;\n    font-size: 16px;\n    line-height: 16px;\n}\n\n.parameters-table th {\n    background-color: #f2f2f2;\n    color: #2c2c2c;\n    font-weight: bold;\n}\n\n\n.parameters-table .bg-gray {\n    background-color: #f2f2f2;  \n}\n\n\n.options-table-wrapper {\n    overflow-x: auto; \n    -webkit-overflow-scrolling: touch; \n    margin-top: 0px;\n}\n\n.options-table {\n    width: 100%;\n    min-width: 1000px; \n    border-collapse: collapse;\n    margin-top: 0px;\n    box-shadow: 0 6px 25px rgba(0, 0, 0, 0.1); \n}\n\n.options-table th, .options-table td {\n    border: 2px solid #000;  \n    padding: 5px 2px;  \n    text-align: center;\n    font-size: 16px;\n    line-height: 16px;\n}\n\n.options-table th {\n    background-color: #f2f2f2;\n    color: #2c2c2c;\n    font-weight: bold;\n}\n\n\n.parameters-table2 {\n    width: 100%;\n    min-width: 1000px; \n    border-collapse: collapse;\n    margin-top: 0px;\n}\n\n.parameters-table2 th, .parameters-table2 td {\n    border-top: 1.2px solid #a6a6a6;  \n    border-bottom: 1.2px solid #a6a6a6; \n    border-left: none;  \n    border-right: none; \n    padding: 5px 2px;\n    text-align: center;\n    font-size: 16px;\n    line-height: 16px;\n}\n\n.parameters-table2 th {\n    background-color: #f2f2f2;\n    color: #2c2c2c;\n    font-weight: bold;\n}\n\n\n.parameters-table2 .bg-gray {\n    background-color: #f2f2f2;  \n}\n\n\n.options-table-wrapper2 {\n    overflow-x: auto; \n    -webkit-overflow-scrolling: touch; \n    margin-top: 0px;\n}\n\n        .instruction-container {\n             display: flex;\n             justify-content: space-between;\n             align-items: flex-start;\n             gap: 10px; \/* Adds space between the video and the text *\/\n             margin-bottom: 0px; \/* Adds some space below the section *\/\n        }\n\n      \n        .img-container {\n              width: 50%; \n             display: flex;\n             justify-content: center; \n        }\n\n      \n        .text-container {\n               width: 50%; \n             font-size: 16px;\n             font-family: Arial;\n             \n         }\n\n         .instruction-container2 {\n             display: flex;\n             justify-content: space-between;\n             align-items: flex-start;\n             gap: 10px; \/* Adds space between the video and the text *\/\n             margin-bottom: 0px; \/* Adds some space below the section *\/\n        }\n\n      \n        .img-container2 {\n             width: 50%; \n             display: flex;\n             justify-content: center; \n        }\n\n      \n        .text-container2 {\n             width: 50%; \n            display: flex;\n             justify-content: center;\n         }\n\n\/* FAQ专属 图片+文字容器 40%+60%占比 - 不影响其他instruction-container *\/\n.instruction-container-faq {\n    display: flex;\n    justify-content: space-between;\n    align-items: flex-start;\n    gap: 10px;\n    margin-bottom: 0px;\n}\n.img-container-faq {\n    width: 35%; \/* FAQ图片占40% *\/\n    display: flex;\n    justify-content: center;\n}\n.text-container-faq {\n    width: 65%; \/* FAQ文字占60% *\/\n    font-size: 16px;\n    font-family: Arial;\n}\n\/* FAQ专属 移动端适配 - 自动上下排列 *\/\n@media (max-width: 768px) {\n    .instruction-container-faq {\n        flex-direction: column;\n        align-items: center;\n    }\n    .img-container-faq, .text-container-faq {\n        width: 100%;\n        margin-bottom: 0px;\n    }\n}\n\n@media (max-width: 768px) {\n    .parameters-table th, .parameters-table td {\n        font-size: 14px; \n        padding: 8px 4px; \n    }\n\n   \n    .options-table th, .options-table td {\n        font-size: 14px; \n        padding: 8px 4px;\n    }\n\n    .parameters-table-wrapper {\n        overflow-x: auto;\n    }\n    .parameters-table2 th, .parameters-table2 td {\n        font-size: 14px; \n        padding: 8px 4px; \n    }\n    .parameters-table-wrapper2 {\n        overflow-x: auto;\n    }\n    .desktop-img {\n                display: none;\n            }\n            .mobile-img {\n                display: block; \n            }\n    .instruction-container {\n                flex-direction: column; \n                align-items: center;\n            }\n\n            .img-container, .text-container {\n                width: 100%; \/* Both take full width *\/\n                margin-bottom: 0px; \n            }\n            .instruction-container2 {\n                flex-direction: column; \n                align-items: center;\n            }\n\n            .img-container2, .text-container2 {\n                width: 100%; \/* Both take full width *\/\n                margin-bottom: 0px; \n            }\n    \n}\n\n@media (max-width: 480px) {\n    .parameters-table th, .parameters-table td {\n        font-size: 12px; \n        padding: 6px 3px; \n    }\n\n    \n    .options-table th, .options-table td {\n        font-size: 12px; \n    }\n\n    .parameters-table-wrapper {\n        overflow-x: auto;\n    }\n    .parameters-table2 th, .parameters-table2 td {\n        font-size: 12px; \n        padding: 6px 3px; \n    }\n    .parameters-table-wrapper2 {\n        overflow-x: auto;\n    }\n    .desktop-img {\n                display: none; \n            }\n            .mobile-img {\n                display: block; \n            }\n    .instruction-container {\n                flex-direction: column; \n            }\n            .instruction-container2 {\n                flex-direction: column; \n            }\n    \n}\n    \u003c\/style\u003e\n\u003c!-- background --\u003e\n\u003cp\u003e\u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/jfmsv-WiFi-plug-a.jpg\"\u003e \u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/jfmsv-WiFi-plug-a-p.jpg\"\u003e\u003c\/p\u003e\n\u003c!-- Introduction --\u003e\n\u003cdiv\u003e\n\u003ch2 class=\"section-title\"\u003eIntroduction\u003c\/h2\u003e\n\u003cp class=\"section-description\"\u003eThe U.S. Solid Smart Motorized Ball Valve is a cutting-edge motorized ball valve with built-in smart control technology. Easily control the valve using your mobile device via Wi-Fi, with no complicated installation required. Simply download the app, connect to Wi-Fi, and remotely open or close the valve with a few taps. Enjoy unmatched convenience and ease of use compared to traditional valves. Perfect for controlling water, gas, or other fluids with reliable and accurate control every time.\u003cbr\u003eCompared to the basic model of smart motorized ball valve (powered by DC 5V via USB), this series comes with a plug-in AC-DC adapter that converts AC 100V-240V to DC 5V, enabling direct power supply from standard household AC outlets.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- Applications--\u003e\n\u003ch2 class=\"section-title2\"\u003eApplications\u003c\/h2\u003e\n\u003cp\u003e\u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFSV\/JFSV-smart-plug-a.jpg\"\u003e \u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFSV\/JFSV-a-p.jpg\"\u003e\u003c\/p\u003e\n\u003c!-- Smart Control--\u003e\n\u003ch2 class=\"section-title2\"\u003eSmart Control\u003c\/h2\u003e\n\u003cp class=\"section-description\"\u003eThe smart motorized ball valve features a smart-control function, providing you with the convenience of controlling your valve using your cellphone. Furthermore, once the valve is connected to your WiFi, you can remotely control the valve even when you are away from home.\u003cbr\u003eThis feature allows for seamless and convenient operation of the valve from anywhere at any time.In addition to its smart control capabilities, the motorized ball valve is also equipped with a manual switch, providing an added layer of assurance and peace of mind.\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFSV\/JFSV-smart-plug.jpg\"\u003e \u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFSV\/JFSV-smart-plug-p-1.jpg\"\u003e \u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFSV\/JFSV-smart-plug-p-2.jpg\"\u003e\u003c\/p\u003e\n\u003c!-- Features --\u003e\n\u003cdiv\u003e\n\u003ch2 class=\"section-title\"\u003eFeatures\u003c\/h2\u003e\n\u003cul class=\"section-description2\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eOpen Percentage:\u003c\/strong\u003e Set the open percentage for precise flow regulation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePlug Connection:\u003c\/strong\u003eEquipped with an included AC-DC adapter (converts AC 100V–240V to DC 5V) for direct wall outlet power supply.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFull Port:\u003c\/strong\u003e Maximum flow efficiency, zero restriction.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNormally Closed:\u003c\/strong\u003e Closed when unpowered, opens when energized.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNPT\/G Threading:\u003c\/strong\u003e NPT (National Pipe Taper) and G (BSPP) threading to accommodate diverse global specifications, ensuring a secure seal with \u003ca href=\"https:\/\/ussolid.com\/products\/u-s-solid-10-rolls-0-7-inch-w-x-905-inches-l-teflon-tape-plumbers-tape-yellow-shell-html?_pos=3\u0026amp;_sid=7aa2e2725\u0026amp;_ss=r\" target=\"_blank\"\u003eteflon tape\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eValve Body Material:\u003c\/strong\u003e Constructed from corrosion-resistant stainless steel and is NSF\/ANSI\/CAN 61 certified. Suitable for drinking water applications (compliant with standards).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePTFE Seal:\u003c\/strong\u003e Superior to NBR and Viton in sealing, temperature, and pressure resistance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFSV\/jfsv-smart-plug-ss.jpg\"\u003e \u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFSV\/jfsv-smart-plug-ss-p.jpg\"\u003e\u003c\/p\u003e\n\u003c!-- Technical Data --\u003e\n\u003ch2 class=\"section-title3\"\u003eTechnical Data\u003c\/h2\u003e\n\u003cdiv class=\"parameters-table-wrapper\"\u003e\n\u003ctable class=\"parameters-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eUSS-MSV00455\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eProduct Name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eSmart Motorized Ball Valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eBore Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eFull Port\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eLife Expectancy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e80,000-100,000 Cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eStatus Indicator\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eYes\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eFlow Aperture\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e20 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eThread Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eNPT\/G\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eOperating State\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eNormally Closed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eSize\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e3\/4\"\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eWiring Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003ePlug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eValve Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eStainless Steel\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eBall Seal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003ePTFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eOperating Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e8-10 Seconds\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eWorking Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eConverts AC 100V–240V to DC 5V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eMax Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e5W\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eMax Torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e10 N·m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eMedium Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e32℉ to 194℉\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eAmbient Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-4℉ to 113℉\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eMax Medium Pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e145 PSI (1.0 Mpa)\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eCompatible Media\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eWater, air, oil and gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eGross Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2.03 lbs\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003ePackage Dimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e6.30\"x4.72\"x4.13\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eUSB Cable Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2.1 m \/ 6.9 ft\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp class=\"section-description\"\u003e*To view the full table on mobile, please swipe left or right on the screen.\u003c\/p\u003e\n\u003c!-- User Manual --\u003e\n\n\u003ch2 class=\"section-title3\"\u003eCE Certified Quality \u0026amp; Safety\u003c\/h2\u003e\n\u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/CE\/CE.jpg\"\u003e\n\u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/CE\/CE.jpg\"\u003e\n\u003ch2 class=\"section-title\"\u003eUser Manual\u003c\/h2\u003e\n\u003cp class=\"section-description\"\u003eTo learn how to use this product, please refer to the \u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/Instruction%20Manual-U.S.%20Solid%20Smart%20Motorized%20Ball%20Valve2025.pdf\" target=\"_blank\"\u003euser manual\u003c\/a\u003e or watch the \u003ca href=\"https:\/\/youtu.be\/PfpgH29YU-s?list=TLGGw48OMJtyzq8yMTA3MjAyNQ\" target=\"_blank\"\u003etutorial video\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\u003cstrong\u003eNote:\u003c\/strong\u003eThe GIF demonstrates flow control by setting Open Percentage (100% = fully open, 0% = fully closed).\u003c\/p\u003e\n\u003cdiv class=\"instruction-container\"\u003e\n\u003cdiv class=\"img-container\"\u003e\u003cimg alt=\"\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif11.gif\" style=\"width: 100%; height: auto;\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"text-container\"\u003e\u003cimg alt=\"\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif12.gif\" style=\"width: 100%; height: auto;\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- FAQ --\u003e\n\u003ch2 class=\"section-title\"\u003eFAQ\u003c\/h2\u003e\n\u003cp class=\"faq\"\u003e\u003cb\u003eProblem 1: What's the difference between this series and the basic Smart Motorized Ball Valve model?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003eWhile the basic model operates on DC5V via USB, this series includes a plug adapter that converts AC100V-240V to DC5V for direct wall outlet connection.\u003c\/p\u003e\n\u003cp class=\"faq\"\u003e\u003cb\u003eProblem 2: Can the Smart Motorized Ball Valve only be controlled via the app?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\u003cstrong\u003eNo\u003c\/strong\u003e, it also features a manual push-button for local control.\u003c\/p\u003e\n\u003cp class=\"faq\"\u003e\u003cb\u003eProblem 3: This smart ball valve is marked as normally closed – can its power-off passage state be modified via the app?\u003c\/b\u003e\u003c\/p\u003e\n\u003cdiv class=\"instruction-container-faq\"\u003e\n\u003cdiv class=\"img-container-faq\"\u003e\u003cimg alt=\"\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFSV\/jfsv-smart-plug-off.jpg\" style=\"width: 100%; height: auto;\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"text-container-faq\"\u003e\n\u003cp class=\"section-title\"\u003eTap “Settings” to set\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003eThis smart ball valve is factory default set to a normally closed state (valve passage closes automatically when power is lost), and you can freely adjust its power-off working state according to your actual usage needs through the dedicated mobile app.\u003c\/p\u003e\n\u003cp class=\"section-title\"\u003eThree states\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003eSelect the specific power-off state you need for the valve, and the setting will be automatically saved immediately once you make your selection, no additional save operation is required.\u003c\/p\u003e\n\u003cul class=\"section-description2\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eOff:\u003c\/strong\u003e The valve passage stays closed when power is lost (consistent with the default setting).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOn:\u003c\/strong\u003e The valve passage remains open when power is lost.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMemory:\u003c\/strong\u003e The valve passage maintains its last working position before the power failure.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp class=\"faq\"\u003e\u003cb\u003eProblem 4: What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n\u003cul class=\"section-description2\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eFull Port:\u003c\/strong\u003e Matches pipe diameter, minimal flow restriction, ideal for high flow and low pressure drop.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard Port:\u003c\/strong\u003e Smaller than pipe diameter, higher resistance, suitable for general flow and pressure needs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"faq\"\u003e\u003cb\u003eProblem 5: Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\u003cstrong\u003eYes.\u003c\/strong\u003e This valve is made of food-grade stainless steel, meeting drinking water standards and is NSF\/ANSI\/CAN 61 certified. It is safe for potable water with no lead risk (unlike brass valves).\u003c\/p\u003e","brand":"U.S. Solid","offers":[{"title":"NPT","offer_id":47129063981311,"sku":"JFMSV00455","price":105.09,"currency_code":"USD","in_stock":true},{"title":"G","offer_id":47158082371839,"sku":"JFMSV00455-G","price":105.09,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/2_962ef412-76b8-4a73-b325-85b7952fe92d.jpg?v=1755587705"},{"product_id":"wifi-1-stainless-steel-remote-control-motorized-ball-valve-with-power-off-memory-ac-100-240v-plug-adapter-with-dc-5v-output-manual-switch","title":"WiFi 1\" Stainless Steel Remote Control Motorized Ball Valve with Power-Off Memory, AC 100-240V Plug Adapter with DC 5V Output, Manual Switch","description":"\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e \u003cmeta content=\"width=device-width, initial-scale=1.0\" name=\"viewport\"\u003e\u003c\/p\u003e\n\u003cstyle\u003e\n        \n        .desktop-img {\n            display: block;\n        }\n        .mobile-img {\n            display: none;\n        } \n        \n        .section-title {\n            font-size: 22px;\n            line-height: 22px;\n            font-weight: bold;\n            margin: 15px 0 5px; \n            font-family: Arial;\n        }\n        \n        .section-title2 {\n            font-size: 22px;\n            line-height: 22px;\n            font-weight: bold;\n            margin: 15px 0 3px; \n            font-family: Arial;\n        }\n       \n        .section-title3 {\n            font-size: 22px;\n            line-height: 22px;\n            font-weight: bold;\n            margin: 15px 0 10px; \n            font-family: Arial;\n        }\n\n        \n        .section-description {\n            font-size: 16px;\n            line-height: 26px;\n            margin-top: 0px;\n            margin-bottom: 5px; \n            font-family: Arial;\n        }\n      \n        .faq {\n            font-size: 16px; \n            margin: 0; \n            line-height: 26px; \n            background-color: #f2f2f2; \n            padding: 5px;\n        }\n        \n        .section-description2 {\n            font-size: 16px;\n            line-height: 26px;\n            margin: 0px; \n            font-family: Arial;\n        }\n        \n.parameters-table-wrapper {\n    overflow-x: auto; \n    -webkit-overflow-scrolling: touch; \n    margin-top: 0px;\n}\n\n\n.parameters-table {\n    width: 100%;\n    min-width: 1000px;\n    border-collapse: collapse;\n    margin-top: 0px;\n}\n\n.parameters-table th, .parameters-table td {\n    border-top: 1.2px solid #a6a6a6; \n    border-bottom: 1.2px solid #a6a6a6;  \n    border-left: none;  \n    border-right: none;  \n    padding: 5px 2px;\n    text-align: left;\n    font-size: 16px;\n    line-height: 16px;\n}\n\n.parameters-table th {\n    background-color: #f2f2f2;\n    color: #2c2c2c;\n    font-weight: bold;\n}\n\n\n.parameters-table .bg-gray {\n    background-color: #f2f2f2;  \n}\n\n\n.options-table-wrapper {\n    overflow-x: auto; \n    -webkit-overflow-scrolling: touch; \n    margin-top: 0px;\n}\n\n.options-table {\n    width: 100%;\n    min-width: 1000px; \n    border-collapse: collapse;\n    margin-top: 0px;\n    box-shadow: 0 6px 25px rgba(0, 0, 0, 0.1); \n}\n\n.options-table th, .options-table td {\n    border: 2px solid #000;  \n    padding: 5px 2px;  \n    text-align: center;\n    font-size: 16px;\n    line-height: 16px;\n}\n\n.options-table th {\n    background-color: #f2f2f2;\n    color: #2c2c2c;\n    font-weight: bold;\n}\n\n\n.parameters-table2 {\n    width: 100%;\n    min-width: 1000px; \n    border-collapse: collapse;\n    margin-top: 0px;\n}\n\n.parameters-table2 th, .parameters-table2 td {\n    border-top: 1.2px solid #a6a6a6;  \n    border-bottom: 1.2px solid #a6a6a6; \n    border-left: none;  \n    border-right: none; \n    padding: 5px 2px;\n    text-align: center;\n    font-size: 16px;\n    line-height: 16px;\n}\n\n.parameters-table2 th {\n    background-color: #f2f2f2;\n    color: #2c2c2c;\n    font-weight: bold;\n}\n\n\n.parameters-table2 .bg-gray {\n    background-color: #f2f2f2;  \n}\n\n\n.options-table-wrapper2 {\n    overflow-x: auto; \n    -webkit-overflow-scrolling: touch; \n    margin-top: 0px;\n}\n\n        .instruction-container {\n             display: flex;\n             justify-content: space-between;\n             align-items: flex-start;\n             gap: 10px; \/* Adds space between the video and the text *\/\n             margin-bottom: 0px; \/* Adds some space below the section *\/\n        }\n\n      \n        .img-container {\n              width: 50%; \n             display: flex;\n             justify-content: center; \n        }\n\n      \n        .text-container {\n               width: 50%; \n             font-size: 16px;\n             font-family: Arial;\n             \n         }\n\n         .instruction-container2 {\n             display: flex;\n             justify-content: space-between;\n             align-items: flex-start;\n             gap: 10px; \/* Adds space between the video and the text *\/\n             margin-bottom: 0px; \/* Adds some space below the section *\/\n        }\n\n      \n        .img-container2 {\n             width: 50%; \n             display: flex;\n             justify-content: center; \n        }\n\n      \n        .text-container2 {\n             width: 50%; \n            display: flex;\n             justify-content: center;\n         }\n\n\/* FAQ专属 图片+文字容器 40%+60%占比 - 不影响其他instruction-container *\/\n.instruction-container-faq {\n    display: flex;\n    justify-content: space-between;\n    align-items: flex-start;\n    gap: 10px;\n    margin-bottom: 0px;\n}\n.img-container-faq {\n    width: 35%; \/* FAQ图片占40% *\/\n    display: flex;\n    justify-content: center;\n}\n.text-container-faq {\n    width: 65%; \/* FAQ文字占60% *\/\n    font-size: 16px;\n    font-family: Arial;\n}\n\/* FAQ专属 移动端适配 - 自动上下排列 *\/\n@media (max-width: 768px) {\n    .instruction-container-faq {\n        flex-direction: column;\n        align-items: center;\n    }\n    .img-container-faq, .text-container-faq {\n        width: 100%;\n        margin-bottom: 0px;\n    }\n}\n\n@media (max-width: 768px) {\n    .parameters-table th, .parameters-table td {\n        font-size: 14px; \n        padding: 8px 4px; \n    }\n\n   \n    .options-table th, .options-table td {\n        font-size: 14px; \n        padding: 8px 4px;\n    }\n\n    .parameters-table-wrapper {\n        overflow-x: auto;\n    }\n    .parameters-table2 th, .parameters-table2 td {\n        font-size: 14px; \n        padding: 8px 4px; \n    }\n    .parameters-table-wrapper2 {\n        overflow-x: auto;\n    }\n    .desktop-img {\n                display: none;\n            }\n            .mobile-img {\n                display: block; \n            }\n    .instruction-container {\n                flex-direction: column; \n                align-items: center;\n            }\n\n            .img-container, .text-container {\n                width: 100%; \/* Both take full width *\/\n                margin-bottom: 0px; \n            }\n            .instruction-container2 {\n                flex-direction: column; \n                align-items: center;\n            }\n\n            .img-container2, .text-container2 {\n                width: 100%; \/* Both take full width *\/\n                margin-bottom: 0px; \n            }\n    \n}\n\n@media (max-width: 480px) {\n    .parameters-table th, .parameters-table td {\n        font-size: 12px; \n        padding: 6px 3px; \n    }\n\n    \n    .options-table th, .options-table td {\n        font-size: 12px; \n    }\n\n    .parameters-table-wrapper {\n        overflow-x: auto;\n    }\n    .parameters-table2 th, .parameters-table2 td {\n        font-size: 12px; \n        padding: 6px 3px; \n    }\n    .parameters-table-wrapper2 {\n        overflow-x: auto;\n    }\n    .desktop-img {\n                display: none; \n            }\n            .mobile-img {\n                display: block; \n            }\n    .instruction-container {\n                flex-direction: column; \n            }\n            .instruction-container2 {\n                flex-direction: column; \n            }\n    \n}\n    \u003c\/style\u003e\n\u003c!-- background --\u003e\n\u003cp\u003e\u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/jfmsv-WiFi-plug-a.jpg\"\u003e \u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/jfmsv-WiFi-plug-a-p.jpg\"\u003e\u003c\/p\u003e\n\u003c!-- Introduction --\u003e\n\u003cdiv\u003e\n\u003ch2 class=\"section-title\"\u003eIntroduction\u003c\/h2\u003e\n\u003cp class=\"section-description\"\u003eThe U.S. Solid Smart Motorized Ball Valve is a cutting-edge motorized ball valve with built-in smart control technology. Easily control the valve using your mobile device via Wi-Fi, with no complicated installation required. Simply download the app, connect to Wi-Fi, and remotely open or close the valve with a few taps. Enjoy unmatched convenience and ease of use compared to traditional valves. Perfect for controlling water, gas, or other fluids with reliable and accurate control every time.\u003cbr\u003eCompared to the basic model of smart motorized ball valve (powered by DC 5V via USB), this series comes with a plug-in AC-DC adapter that converts AC 100V-240V to DC 5V, enabling direct power supply from standard household AC outlets.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- Applications--\u003e\n\u003ch2 class=\"section-title2\"\u003eApplications\u003c\/h2\u003e\n\u003cp\u003e\u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFSV\/JFSV-smart-plug-a.jpg\"\u003e \u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFSV\/JFSV-a-p.jpg\"\u003e\u003c\/p\u003e\n\u003c!-- Smart Control--\u003e\n\u003ch2 class=\"section-title2\"\u003eSmart Control\u003c\/h2\u003e\n\u003cp class=\"section-description\"\u003eThe smart motorized ball valve features a smart-control function, providing you with the convenience of controlling your valve using your cellphone. Furthermore, once the valve is connected to your WiFi, you can remotely control the valve even when you are away from home.\u003cbr\u003eThis feature allows for seamless and convenient operation of the valve from anywhere at any time.In addition to its smart control capabilities, the motorized ball valve is also equipped with a manual switch, providing an added layer of assurance and peace of mind.\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFSV\/JFSV-smart-plug.jpg\"\u003e \u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFSV\/JFSV-smart-plug-p-1.jpg\"\u003e \u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFSV\/JFSV-smart-plug-p-2.jpg\"\u003e\u003c\/p\u003e\n\u003c!-- Features --\u003e\n\u003cdiv\u003e\n\u003ch2 class=\"section-title\"\u003eFeatures\u003c\/h2\u003e\n\u003cul class=\"section-description2\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eOpen Percentage:\u003c\/strong\u003e Set the open percentage for precise flow regulation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePlug Connection:\u003c\/strong\u003e Equipped with an included AC-DC adapter (converts AC 100V–240V to DC 5V) for direct wall outlet power supply.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFull Port:\u003c\/strong\u003e Maximum flow efficiency, zero restriction.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNormally Closed:\u003c\/strong\u003e Closed when unpowered, opens when energized.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNPT\/G Threading:\u003c\/strong\u003e NPT (National Pipe Taper) and G (BSPP) threading to accommodate diverse global specifications, ensuring a secure seal with \u003ca href=\"https:\/\/ussolid.com\/products\/u-s-solid-10-rolls-0-7-inch-w-x-905-inches-l-teflon-tape-plumbers-tape-yellow-shell-html?_pos=3\u0026amp;_sid=7aa2e2725\u0026amp;_ss=r\" target=\"_blank\"\u003eteflon tape\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eValve Body Material:\u003c\/strong\u003e Constructed from corrosion-resistant stainless steel and is NSF\/ANSI\/CAN 61 certified. Suitable for drinking water applications (compliant with standards).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePTFE Seal:\u003c\/strong\u003e Superior to NBR and Viton in sealing, temperature, and pressure resistance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFSV\/jfsv-smart-plug-ss.jpg\"\u003e \u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFSV\/jfsv-smart-plug-ss-p.jpg\"\u003e\u003c\/p\u003e\n\u003c!-- Technical Data --\u003e\n\u003ch2 class=\"section-title3\"\u003eTechnical Data\u003c\/h2\u003e\n\u003cdiv class=\"parameters-table-wrapper\"\u003e\n\u003ctable class=\"parameters-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eUSS-MSV00456\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eProduct Name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eSmart Motorized Ball Valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eBore Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eFull Port\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eLife Expectancy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e80,000-100,000 Cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eStatus Indicator\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eYes\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eFlow Aperture\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e25 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eThread Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eNPT\/G\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eOperating State\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eNormally Closed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eSize\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1\"\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eWiring Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003ePlug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eValve Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eStainless Steel\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eBall Seal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003ePTFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eOperating Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e8-10 Seconds\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eWorking Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eConverts AC 100V–240V to DC 5V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eMax Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e5W\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eMax Torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e10 N·m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eMedium Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e32℉ to 194℉\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eAmbient Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-4℉ to 113℉\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eMax Medium Pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e145 PSI (1.0 Mpa)\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eCompatible Media\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eWater, air, oil and gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eGross Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2.25 lbs\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003ePackage Dimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e6.30\"x4.72\"x4.13\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eUSB Cable Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2.1 m \/ 6.9 ft\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp class=\"section-description\"\u003e*To view the full table on mobile, please swipe left or right on the screen.\u003c\/p\u003e\n\u003c!-- User Manual --\u003e\n\n\u003ch2 class=\"section-title3\"\u003eCE Certified Quality \u0026amp; Safety\u003c\/h2\u003e\n\u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/CE\/CE.jpg\"\u003e\n\u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/CE\/CE.jpg\"\u003e\n\u003ch2 class=\"section-title\"\u003eUser Manual\u003c\/h2\u003e\n\u003cp class=\"section-description\"\u003eTo learn how to use this product, please refer to the \u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/Instruction%20Manual-U.S.%20Solid%20Smart%20Motorized%20Ball%20Valve2025.pdf\" target=\"_blank\"\u003euser manual\u003c\/a\u003e or watch the \u003ca href=\"https:\/\/youtu.be\/PfpgH29YU-s?list=TLGGw48OMJtyzq8yMTA3MjAyNQ\" target=\"_blank\"\u003etutorial video\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\u003cstrong\u003eNote:\u003c\/strong\u003eThe GIF demonstrates flow control by setting Open Percentage (100% = fully open, 0% = fully closed).\u003c\/p\u003e\n\u003cdiv class=\"instruction-container\"\u003e\n\u003cdiv class=\"img-container\"\u003e\u003cimg alt=\"\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif11.gif\" style=\"width: 100%; height: auto;\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"text-container\"\u003e\u003cimg alt=\"\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif12.gif\" style=\"width: 100%; height: auto;\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- FAQ --\u003e\n\u003ch2 class=\"section-title\"\u003eFAQ\u003c\/h2\u003e\n\u003cp class=\"faq\"\u003e\u003cb\u003eProblem 1: What's the difference between this series and the basic Smart Motorized Ball Valve model?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003eWhile the basic model operates on DC5V via USB, this series includes a plug adapter that converts AC100V-240V to DC5V for direct wall outlet connection.\u003c\/p\u003e\n\u003cp class=\"faq\"\u003e\u003cb\u003eProblem 2: Can the Smart Motorized Ball Valve only be controlled via the app?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\u003cstrong\u003eNo\u003c\/strong\u003e, it also features a manual push-button for local control.\u003c\/p\u003e\n\u003cp class=\"faq\"\u003e\u003cb\u003eProblem 3: This smart ball valve is marked as normally closed – can its power-off passage state be modified via the app?\u003c\/b\u003e\u003c\/p\u003e\n\u003cdiv class=\"instruction-container-faq\"\u003e\n\u003cdiv class=\"img-container-faq\"\u003e\u003cimg alt=\"\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFSV\/jfsv-smart-plug-off.jpg\" style=\"width: 100%; height: auto;\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"text-container-faq\"\u003e\n\u003cp class=\"section-title\"\u003eTap “Settings” to set\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003eThis smart ball valve is factory default set to a normally closed state (valve passage closes automatically when power is lost), and you can freely adjust its power-off working state according to your actual usage needs through the dedicated mobile app.\u003c\/p\u003e\n\u003cp class=\"section-title\"\u003eThree states\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003eSelect the specific power-off state you need for the valve, and the setting will be automatically saved immediately once you make your selection, no additional save operation is required.\u003c\/p\u003e\n\u003cul class=\"section-description2\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eOff:\u003c\/strong\u003e The valve passage stays closed when power is lost (consistent with the default setting).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOn:\u003c\/strong\u003e The valve passage remains open when power is lost.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMemory:\u003c\/strong\u003e The valve passage maintains its last working position before the power failure.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp class=\"faq\"\u003e\u003cb\u003eProblem 4: What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n\u003cul class=\"section-description2\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eFull Port:\u003c\/strong\u003e Matches pipe diameter, minimal flow restriction, ideal for high flow and low pressure drop.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard Port:\u003c\/strong\u003e Smaller than pipe diameter, higher resistance, suitable for general flow and pressure needs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"faq\"\u003e\u003cb\u003eProblem 5: Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\u003cstrong\u003eYes.\u003c\/strong\u003e This valve is made of food-grade stainless steel, meeting drinking water standards and is NSF\/ANSI\/CAN 61 certified. It is safe for potable water with no lead risk (unlike brass valves).\u003c\/p\u003e","brand":"U.S. Solid","offers":[{"title":"NPT","offer_id":47129064505599,"sku":"JFMSV00456","price":115.09,"currency_code":"USD","in_stock":true},{"title":"G","offer_id":47158106652927,"sku":"JFMSV00456-G","price":109.09,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/1_2bd346fa-ca3f-494e-a0b7-b280de6a51aa.jpg?v=1755587954"},{"product_id":"wifi-1-14-stainless-steel-remote-control-motorized-ball-valve-with-power-off-memory-ac-100-240v-plug-adapter-with-dc-5v-output-manual-switch","title":"WiFi 1-1\/4\" Stainless Steel Remote Control Motorized Ball Valve with Power-Off Memory, AC 100-240V Plug Adapter with DC 5V Output, Manual Switch","description":"\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e \u003cmeta content=\"width=device-width, initial-scale=1.0\" name=\"viewport\"\u003e\u003c\/p\u003e\n\u003cstyle\u003e\n        \n        .desktop-img {\n            display: block;\n        }\n        .mobile-img {\n            display: none;\n        } \n        \n        .section-title {\n            font-size: 22px;\n            line-height: 22px;\n            font-weight: bold;\n            margin: 15px 0 5px; \n            font-family: Arial;\n        }\n        \n        .section-title2 {\n            font-size: 22px;\n            line-height: 22px;\n            font-weight: bold;\n            margin: 15px 0 3px; \n            font-family: Arial;\n        }\n       \n        .section-title3 {\n            font-size: 22px;\n            line-height: 22px;\n            font-weight: bold;\n            margin: 15px 0 10px; \n            font-family: Arial;\n        }\n\n        \n        .section-description {\n            font-size: 16px;\n            line-height: 26px;\n            margin-top: 0px;\n            margin-bottom: 5px; \n            font-family: Arial;\n        }\n      \n        .faq {\n            font-size: 16px; \n            margin: 0; \n            line-height: 26px; \n            background-color: #f2f2f2; \n            padding: 5px;\n        }\n        \n        .section-description2 {\n            font-size: 16px;\n            line-height: 26px;\n            margin: 0px; \n            font-family: Arial;\n        }\n        \n.parameters-table-wrapper {\n    overflow-x: auto; \n    -webkit-overflow-scrolling: touch; \n    margin-top: 0px;\n}\n\n\n.parameters-table {\n    width: 100%;\n    min-width: 1000px;\n    border-collapse: collapse;\n    margin-top: 0px;\n}\n\n.parameters-table th, .parameters-table td {\n    border-top: 1.2px solid #a6a6a6; \n    border-bottom: 1.2px solid #a6a6a6;  \n    border-left: none;  \n    border-right: none;  \n    padding: 5px 2px;\n    text-align: left;\n    font-size: 16px;\n    line-height: 16px;\n}\n\n.parameters-table th {\n    background-color: #f2f2f2;\n    color: #2c2c2c;\n    font-weight: bold;\n}\n\n\n.parameters-table .bg-gray {\n    background-color: #f2f2f2;  \n}\n\n\n.options-table-wrapper {\n    overflow-x: auto; \n    -webkit-overflow-scrolling: touch; \n    margin-top: 0px;\n}\n\n.options-table {\n    width: 100%;\n    min-width: 1000px; \n    border-collapse: collapse;\n    margin-top: 0px;\n    box-shadow: 0 6px 25px rgba(0, 0, 0, 0.1); \n}\n\n.options-table th, .options-table td {\n    border: 2px solid #000;  \n    padding: 5px 2px;  \n    text-align: center;\n    font-size: 16px;\n    line-height: 16px;\n}\n\n.options-table th {\n    background-color: #f2f2f2;\n    color: #2c2c2c;\n    font-weight: bold;\n}\n\n\n.parameters-table2 {\n    width: 100%;\n    min-width: 1000px; \n    border-collapse: collapse;\n    margin-top: 0px;\n}\n\n.parameters-table2 th, .parameters-table2 td {\n    border-top: 1.2px solid #a6a6a6;  \n    border-bottom: 1.2px solid #a6a6a6; \n    border-left: none;  \n    border-right: none; \n    padding: 5px 2px;\n    text-align: center;\n    font-size: 16px;\n    line-height: 16px;\n}\n\n.parameters-table2 th {\n    background-color: #f2f2f2;\n    color: #2c2c2c;\n    font-weight: bold;\n}\n\n\n.parameters-table2 .bg-gray {\n    background-color: #f2f2f2;  \n}\n\n\n.options-table-wrapper2 {\n    overflow-x: auto; \n    -webkit-overflow-scrolling: touch; \n    margin-top: 0px;\n}\n\n        .instruction-container {\n             display: flex;\n             justify-content: space-between;\n             align-items: flex-start;\n             gap: 10px; \/* Adds space between the video and the text *\/\n             margin-bottom: 0px; \/* Adds some space below the section *\/\n        }\n\n      \n        .img-container {\n              width: 50%; \n             display: flex;\n             justify-content: center; \n        }\n\n      \n        .text-container {\n               width: 50%; \n             font-size: 16px;\n             font-family: Arial;\n             \n         }\n\n         .instruction-container2 {\n             display: flex;\n             justify-content: space-between;\n             align-items: flex-start;\n             gap: 10px; \/* Adds space between the video and the text *\/\n             margin-bottom: 0px; \/* Adds some space below the section *\/\n        }\n\n      \n        .img-container2 {\n             width: 50%; \n             display: flex;\n             justify-content: center; \n        }\n\n      \n        .text-container2 {\n             width: 50%; \n            display: flex;\n             justify-content: center;\n         }\n\n\/* FAQ专属 图片+文字容器 40%+60%占比 - 不影响其他instruction-container *\/\n.instruction-container-faq {\n    display: flex;\n    justify-content: space-between;\n    align-items: flex-start;\n    gap: 10px;\n    margin-bottom: 0px;\n}\n.img-container-faq {\n    width: 35%; \/* FAQ图片占40% *\/\n    display: flex;\n    justify-content: center;\n}\n.text-container-faq {\n    width: 65%; \/* FAQ文字占60% *\/\n    font-size: 16px;\n    font-family: Arial;\n}\n\/* FAQ专属 移动端适配 - 自动上下排列 *\/\n@media (max-width: 768px) {\n    .instruction-container-faq {\n        flex-direction: column;\n        align-items: center;\n    }\n    .img-container-faq, .text-container-faq {\n        width: 100%;\n        margin-bottom: 0px;\n    }\n}\n\n@media (max-width: 768px) {\n    .parameters-table th, .parameters-table td {\n        font-size: 14px; \n        padding: 8px 4px; \n    }\n\n   \n    .options-table th, .options-table td {\n        font-size: 14px; \n        padding: 8px 4px;\n    }\n\n    .parameters-table-wrapper {\n        overflow-x: auto;\n    }\n    .parameters-table2 th, .parameters-table2 td {\n        font-size: 14px; \n        padding: 8px 4px; \n    }\n    .parameters-table-wrapper2 {\n        overflow-x: auto;\n    }\n    .desktop-img {\n                display: none;\n            }\n            .mobile-img {\n                display: block; \n            }\n    .instruction-container {\n                flex-direction: column; \n                align-items: center;\n            }\n\n            .img-container, .text-container {\n                width: 100%; \/* Both take full width *\/\n                margin-bottom: 0px; \n            }\n            .instruction-container2 {\n                flex-direction: column; \n                align-items: center;\n            }\n\n            .img-container2, .text-container2 {\n                width: 100%; \/* Both take full width *\/\n                margin-bottom: 0px; \n            }\n    \n}\n\n@media (max-width: 480px) {\n    .parameters-table th, .parameters-table td {\n        font-size: 12px; \n        padding: 6px 3px; \n    }\n\n    \n    .options-table th, .options-table td {\n        font-size: 12px; \n    }\n\n    .parameters-table-wrapper {\n        overflow-x: auto;\n    }\n    .parameters-table2 th, .parameters-table2 td {\n        font-size: 12px; \n        padding: 6px 3px; \n    }\n    .parameters-table-wrapper2 {\n        overflow-x: auto;\n    }\n    .desktop-img {\n                display: none; \n            }\n            .mobile-img {\n                display: block; \n            }\n    .instruction-container {\n                flex-direction: column; \n            }\n            .instruction-container2 {\n                flex-direction: column; \n            }\n    \n}\n    \u003c\/style\u003e\n\u003c!-- background --\u003e\n\u003cp\u003e\u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/jfmsv-WiFi-plug-a.jpg\"\u003e \u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/jfmsv-WiFi-plug-a-p.jpg\"\u003e\u003c\/p\u003e\n\u003c!-- Introduction --\u003e\n\u003cdiv\u003e\n\u003ch2 class=\"section-title\"\u003eIntroduction\u003c\/h2\u003e\n\u003cp class=\"section-description\"\u003eThe U.S. Solid Smart Motorized Ball Valve is a cutting-edge motorized ball valve with built-in smart control technology. Easily control the valve using your mobile device via Wi-Fi, with no complicated installation required. Simply download the app, connect to Wi-Fi, and remotely open or close the valve with a few taps. Enjoy unmatched convenience and ease of use compared to traditional valves. Perfect for controlling water, gas, or other fluids with reliable and accurate control every time.\u003cbr\u003eCompared to the basic model of smart motorized ball valve (powered by DC 5V via USB), this series comes with a plug-in AC-DC adapter that converts AC 100V-240V to DC 5V, enabling direct power supply from standard household AC outlets.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- Applications--\u003e\n\u003ch2 class=\"section-title2\"\u003eApplications\u003c\/h2\u003e\n\u003cp\u003e\u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFSV\/JFSV-smart-plug-a.jpg\"\u003e \u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFSV\/JFSV-a-p.jpg\"\u003e\u003c\/p\u003e\n\u003c!-- Smart Control--\u003e\n\u003ch2 class=\"section-title2\"\u003eSmart Control\u003c\/h2\u003e\n\u003cp class=\"section-description\"\u003eThe smart motorized ball valve features a smart-control function, providing you with the convenience of controlling your valve using your cellphone. Furthermore, once the valve is connected to your WiFi, you can remotely control the valve even when you are away from home.\u003cbr\u003eThis feature allows for seamless and convenient operation of the valve from anywhere at any time.In addition to its smart control capabilities, the motorized ball valve is also equipped with a manual switch, providing an added layer of assurance and peace of mind.\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFSV\/JFSV-smart-plug.jpg\"\u003e \u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFSV\/JFSV-smart-plug-p-1.jpg\"\u003e \u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFSV\/JFSV-smart-plug-p-2.jpg\"\u003e\u003c\/p\u003e\n\u003c!-- Features --\u003e\n\u003cdiv\u003e\n\u003ch2 class=\"section-title\"\u003eFeatures\u003c\/h2\u003e\n\u003cul class=\"section-description2\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eOpen Percentage:\u003c\/strong\u003e Set the open percentage for precise flow regulation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePlug Connection:\u003c\/strong\u003e Equipped with an included AC-DC adapter (converts AC 100V–240V to DC 5V) for direct wall outlet power supply.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFull Port:\u003c\/strong\u003e Maximum flow efficiency, zero restriction.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNormally Closed:\u003c\/strong\u003e Closed when unpowered, opens when energized.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNPT\/G Threading:\u003c\/strong\u003e NPT (National Pipe Taper) and G (BSPP) threading to accommodate diverse global specifications, ensuring a secure seal with \u003ca href=\"https:\/\/ussolid.com\/products\/u-s-solid-10-rolls-0-7-inch-w-x-905-inches-l-teflon-tape-plumbers-tape-yellow-shell-html?_pos=3\u0026amp;_sid=7aa2e2725\u0026amp;_ss=r\" target=\"_blank\"\u003eteflon tape\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eValve Body Material:\u003c\/strong\u003e Constructed from corrosion-resistant stainless steel and is NSF\/ANSI\/CAN 61 certified. Suitable for drinking water applications (compliant with standards).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePTFE Seal:\u003c\/strong\u003e Superior to NBR and Viton in sealing, temperature, and pressure resistance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFSV\/jfsv-smart-plug-ss.jpg\"\u003e \u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFSV\/jfsv-smart-plug-ss-p.jpg\"\u003e\u003c\/p\u003e\n\u003c!-- Technical Data --\u003e\n\u003ch2 class=\"section-title3\"\u003eTechnical Data\u003c\/h2\u003e\n\u003cdiv class=\"parameters-table-wrapper\"\u003e\n\u003ctable class=\"parameters-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eUSS-MSV00457\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eProduct Name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eSmart Motorized Ball Valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eBore Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eFull Port\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eLife Expectancy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e80,000-100,000 Cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eStatus Indicator\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eYes\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eFlow Aperture\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e32 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eThread Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eNPT\/G\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eOperating State\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eNormally Closed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eSize\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1-1\/4\"\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eWiring Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003ePlug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eValve Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eStainless Steel\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eBall Seal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003ePTFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eOperating Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e8-10 Seconds\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eWorking Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eConverts AC 100V–240V to DC 5V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eMax Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e5W\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eMax Torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e10 N·m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eMedium Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e32℉ to 194℉\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eAmbient Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-4℉ to 113℉\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eMax Medium Pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e145 PSI (1.0 Mpa)\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eCompatible Media\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eWater, air, oil and gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eGross Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e3.20 lbs\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003ePackage Dimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e6.30\"x4.72\"x4.33\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eUSB Cable Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2.1 m \/ 6.9 ft\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp class=\"section-description\"\u003e*To view the full table on mobile, please swipe left or right on the screen.\u003c\/p\u003e\n\u003c!-- User Manual --\u003e\n\n\u003ch2 class=\"section-title3\"\u003eCE Certified Quality \u0026amp; Safety\u003c\/h2\u003e\n\u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/CE\/CE.jpg\"\u003e\n\u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/CE\/CE.jpg\"\u003e\n\u003ch2 class=\"section-title\"\u003eUser Manual\u003c\/h2\u003e\n\u003cp class=\"section-description\"\u003eTo learn how to use this product, please refer to the \u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/Instruction%20Manual-U.S.%20Solid%20Smart%20Motorized%20Ball%20Valve2025.pdf\" target=\"_blank\"\u003euser manual\u003c\/a\u003e or watch the \u003ca href=\"https:\/\/youtu.be\/PfpgH29YU-s?list=TLGGw48OMJtyzq8yMTA3MjAyNQ\" target=\"_blank\"\u003etutorial video\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\u003cstrong\u003eNote:\u003c\/strong\u003eThe GIF demonstrates flow control by setting Open Percentage (100% = fully open, 0% = fully closed).\u003c\/p\u003e\n\u003cdiv class=\"instruction-container\"\u003e\n\u003cdiv class=\"img-container\"\u003e\u003cimg alt=\"\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif11.gif\" style=\"width: 100%; height: auto;\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"text-container\"\u003e\u003cimg alt=\"\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif12.gif\" style=\"width: 100%; height: auto;\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- FAQ --\u003e\n\u003ch2 class=\"section-title\"\u003eFAQ\u003c\/h2\u003e\n\u003cp class=\"faq\"\u003e\u003cb\u003eProblem 1: What's the difference between this series and the basic Smart Motorized Ball Valve model?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003eWhile the basic model operates on DC5V via USB, this series includes a plug adapter that converts AC100V-240V to DC5V for direct wall outlet connection.\u003c\/p\u003e\n\u003cp class=\"faq\"\u003e\u003cb\u003eProblem 2: Can the Smart Motorized Ball Valve only be controlled via the app?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\u003cstrong\u003eNo\u003c\/strong\u003e, it also features a manual push-button for local control.\u003c\/p\u003e\n\u003cp class=\"faq\"\u003e\u003cb\u003eProblem 3: This smart ball valve is marked as normally closed – can its power-off passage state be modified via the app?\u003c\/b\u003e\u003c\/p\u003e\n\u003cdiv class=\"instruction-container-faq\"\u003e\n\u003cdiv class=\"img-container-faq\"\u003e\u003cimg alt=\"\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFSV\/jfsv-smart-plug-off.jpg\" style=\"width: 100%; height: auto;\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"text-container-faq\"\u003e\n\u003cp class=\"section-title\"\u003eTap “Settings” to set\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003eThis smart ball valve is factory default set to a normally closed state (valve passage closes automatically when power is lost), and you can freely adjust its power-off working state according to your actual usage needs through the dedicated mobile app.\u003c\/p\u003e\n\u003cp class=\"section-title\"\u003eThree states\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003eSelect the specific power-off state you need for the valve, and the setting will be automatically saved immediately once you make your selection, no additional save operation is required.\u003c\/p\u003e\n\u003cul class=\"section-description2\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eOff:\u003c\/strong\u003e The valve passage stays closed when power is lost (consistent with the default setting).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOn:\u003c\/strong\u003e The valve passage remains open when power is lost.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMemory:\u003c\/strong\u003e The valve passage maintains its last working position before the power failure.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp class=\"faq\"\u003e\u003cb\u003eProblem 4: What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n\u003cul class=\"section-description2\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eFull Port:\u003c\/strong\u003e Matches pipe diameter, minimal flow restriction, ideal for high flow and low pressure drop.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard Port:\u003c\/strong\u003e Smaller than pipe diameter, higher resistance, suitable for general flow and pressure needs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"faq\"\u003e\u003cb\u003eProblem 5: Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\u003cstrong\u003eYes.\u003c\/strong\u003e This valve is made of food-grade stainless steel, meeting drinking water standards and is NSF\/ANSI\/CAN 61 certified. It is safe for potable water with no lead risk (unlike brass valves).\u003c\/p\u003e","brand":"U.S. Solid","offers":[{"title":"NPT","offer_id":47129072369919,"sku":"JFMSV00457","price":135.49,"currency_code":"USD","in_stock":true},{"title":"G","offer_id":47158109733119,"sku":"JFMSV00457-G","price":130.29,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/1_eeaa76a2-fabb-42f5-8917-1ed59a6e931a.jpg?v=1755588711"},{"product_id":"wifi-1-12-stainless-steel-remote-control-motorized-ball-valve-with-power-off-memory-ac-100-240v-plug-adapter-with-dc-5v-output-manual-switch","title":"WiFi 1-1\/2\" Stainless Steel Remote Control Motorized Ball Valve with Power-Off Memory, AC 100-240V Plug Adapter with DC 5V Output, Manual Switch","description":"\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e \u003cmeta content=\"width=device-width, initial-scale=1.0\" name=\"viewport\"\u003e\u003c\/p\u003e\n\u003cstyle\u003e\n        \n        .desktop-img {\n            display: block;\n        }\n        .mobile-img {\n            display: none;\n        } \n        \n        .section-title {\n            font-size: 22px;\n            line-height: 22px;\n            font-weight: bold;\n            margin: 15px 0 5px; \n            font-family: Arial;\n        }\n        \n        .section-title2 {\n            font-size: 22px;\n            line-height: 22px;\n            font-weight: bold;\n            margin: 15px 0 3px; \n            font-family: Arial;\n        }\n       \n        .section-title3 {\n            font-size: 22px;\n            line-height: 22px;\n            font-weight: bold;\n            margin: 15px 0 10px; \n            font-family: Arial;\n        }\n\n        \n        .section-description {\n            font-size: 16px;\n            line-height: 26px;\n            margin-top: 0px;\n            margin-bottom: 5px; \n            font-family: Arial;\n        }\n      \n        .faq {\n            font-size: 16px; \n            margin: 0; \n            line-height: 26px; \n            background-color: #f2f2f2; \n            padding: 5px;\n        }\n        \n        .section-description2 {\n            font-size: 16px;\n            line-height: 26px;\n            margin: 0px; \n            font-family: Arial;\n        }\n        \n.parameters-table-wrapper {\n    overflow-x: auto; \n    -webkit-overflow-scrolling: touch; \n    margin-top: 0px;\n}\n\n\n.parameters-table {\n    width: 100%;\n    min-width: 1000px;\n    border-collapse: collapse;\n    margin-top: 0px;\n}\n\n.parameters-table th, .parameters-table td {\n    border-top: 1.2px solid #a6a6a6; \n    border-bottom: 1.2px solid #a6a6a6;  \n    border-left: none;  \n    border-right: none;  \n    padding: 5px 2px;\n    text-align: left;\n    font-size: 16px;\n    line-height: 16px;\n}\n\n.parameters-table th {\n    background-color: #f2f2f2;\n    color: #2c2c2c;\n    font-weight: bold;\n}\n\n\n.parameters-table .bg-gray {\n    background-color: #f2f2f2;  \n}\n\n\n.options-table-wrapper {\n    overflow-x: auto; \n    -webkit-overflow-scrolling: touch; \n    margin-top: 0px;\n}\n\n.options-table {\n    width: 100%;\n    min-width: 1000px; \n    border-collapse: collapse;\n    margin-top: 0px;\n    box-shadow: 0 6px 25px rgba(0, 0, 0, 0.1); \n}\n\n.options-table th, .options-table td {\n    border: 2px solid #000;  \n    padding: 5px 2px;  \n    text-align: center;\n    font-size: 16px;\n    line-height: 16px;\n}\n\n.options-table th {\n    background-color: #f2f2f2;\n    color: #2c2c2c;\n    font-weight: bold;\n}\n\n\n.parameters-table2 {\n    width: 100%;\n    min-width: 1000px; \n    border-collapse: collapse;\n    margin-top: 0px;\n}\n\n.parameters-table2 th, .parameters-table2 td {\n    border-top: 1.2px solid #a6a6a6;  \n    border-bottom: 1.2px solid #a6a6a6; \n    border-left: none;  \n    border-right: none; \n    padding: 5px 2px;\n    text-align: center;\n    font-size: 16px;\n    line-height: 16px;\n}\n\n.parameters-table2 th {\n    background-color: #f2f2f2;\n    color: #2c2c2c;\n    font-weight: bold;\n}\n\n\n.parameters-table2 .bg-gray {\n    background-color: #f2f2f2;  \n}\n\n\n.options-table-wrapper2 {\n    overflow-x: auto; \n    -webkit-overflow-scrolling: touch; \n    margin-top: 0px;\n}\n\n        .instruction-container {\n             display: flex;\n             justify-content: space-between;\n             align-items: flex-start;\n             gap: 10px; \/* Adds space between the video and the text *\/\n             margin-bottom: 0px; \/* Adds some space below the section *\/\n        }\n\n      \n        .img-container {\n              width: 50%; \n             display: flex;\n             justify-content: center; \n        }\n\n      \n        .text-container {\n               width: 50%; \n             font-size: 16px;\n             font-family: Arial;\n             \n         }\n\n         .instruction-container2 {\n             display: flex;\n             justify-content: space-between;\n             align-items: flex-start;\n             gap: 10px; \/* Adds space between the video and the text *\/\n             margin-bottom: 0px; \/* Adds some space below the section *\/\n        }\n\n      \n        .img-container2 {\n             width: 50%; \n             display: flex;\n             justify-content: center; \n        }\n\n      \n        .text-container2 {\n             width: 50%; \n            display: flex;\n             justify-content: center;\n         }\n\n\/* FAQ专属 图片+文字容器 40%+60%占比 - 不影响其他instruction-container *\/\n.instruction-container-faq {\n    display: flex;\n    justify-content: space-between;\n    align-items: flex-start;\n    gap: 10px;\n    margin-bottom: 0px;\n}\n.img-container-faq {\n    width: 35%; \/* FAQ图片占40% *\/\n    display: flex;\n    justify-content: center;\n}\n.text-container-faq {\n    width: 65%; \/* FAQ文字占60% *\/\n    font-size: 16px;\n    font-family: Arial;\n}\n\/* FAQ专属 移动端适配 - 自动上下排列 *\/\n@media (max-width: 768px) {\n    .instruction-container-faq {\n        flex-direction: column;\n        align-items: center;\n    }\n    .img-container-faq, .text-container-faq {\n        width: 100%;\n        margin-bottom: 0px;\n    }\n}\n\n@media (max-width: 768px) {\n    .parameters-table th, .parameters-table td {\n        font-size: 14px; \n        padding: 8px 4px; \n    }\n\n   \n    .options-table th, .options-table td {\n        font-size: 14px; \n        padding: 8px 4px;\n    }\n\n    .parameters-table-wrapper {\n        overflow-x: auto;\n    }\n    .parameters-table2 th, .parameters-table2 td {\n        font-size: 14px; \n        padding: 8px 4px; \n    }\n    .parameters-table-wrapper2 {\n        overflow-x: auto;\n    }\n    .desktop-img {\n                display: none;\n            }\n            .mobile-img {\n                display: block; \n            }\n    .instruction-container {\n                flex-direction: column; \n                align-items: center;\n            }\n\n            .img-container, .text-container {\n                width: 100%; \/* Both take full width *\/\n                margin-bottom: 0px; \n            }\n            .instruction-container2 {\n                flex-direction: column; \n                align-items: center;\n            }\n\n            .img-container2, .text-container2 {\n                width: 100%; \/* Both take full width *\/\n                margin-bottom: 0px; \n            }\n    \n}\n\n@media (max-width: 480px) {\n    .parameters-table th, .parameters-table td {\n        font-size: 12px; \n        padding: 6px 3px; \n    }\n\n    \n    .options-table th, .options-table td {\n        font-size: 12px; \n    }\n\n    .parameters-table-wrapper {\n        overflow-x: auto;\n    }\n    .parameters-table2 th, .parameters-table2 td {\n        font-size: 12px; \n        padding: 6px 3px; \n    }\n    .parameters-table-wrapper2 {\n        overflow-x: auto;\n    }\n    .desktop-img {\n                display: none; \n            }\n            .mobile-img {\n                display: block; \n            }\n    .instruction-container {\n                flex-direction: column; \n            }\n            .instruction-container2 {\n                flex-direction: column; \n            }\n    \n}\n    \u003c\/style\u003e\n\u003c!-- background --\u003e\n\u003cp\u003e\u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/jfmsv-WiFi-plug-a.jpg\"\u003e \u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/jfmsv-WiFi-plug-a-p.jpg\"\u003e\u003c\/p\u003e\n\u003c!-- Introduction --\u003e\n\u003cdiv\u003e\n\u003ch2 class=\"section-title\"\u003eIntroduction\u003c\/h2\u003e\n\u003cp class=\"section-description\"\u003eThe U.S. Solid Smart Motorized Ball Valve is a cutting-edge motorized ball valve with built-in smart control technology. Easily control the valve using your mobile device via Wi-Fi, with no complicated installation required. Simply download the app, connect to Wi-Fi, and remotely open or close the valve with a few taps. Enjoy unmatched convenience and ease of use compared to traditional valves. Perfect for controlling water, gas, or other fluids with reliable and accurate control every time.\u003cbr\u003eCompared to the basic model of smart motorized ball valve (powered by DC 5V via USB), this series comes with a plug-in AC-DC adapter that converts AC 100V-240V to DC 5V, enabling direct power supply from standard household AC outlets.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- Applications--\u003e\n\u003ch2 class=\"section-title2\"\u003eApplications\u003c\/h2\u003e\n\u003cp\u003e\u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFSV\/JFSV-smart-plug-a.jpg\"\u003e \u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFSV\/JFSV-a-p.jpg\"\u003e\u003c\/p\u003e\n\u003c!-- Smart Control--\u003e\n\u003ch2 class=\"section-title2\"\u003eSmart Control\u003c\/h2\u003e\n\u003cp class=\"section-description\"\u003eThe smart motorized ball valve features a smart-control function, providing you with the convenience of controlling your valve using your cellphone. Furthermore, once the valve is connected to your WiFi, you can remotely control the valve even when you are away from home.\u003cbr\u003eThis feature allows for seamless and convenient operation of the valve from anywhere at any time.In addition to its smart control capabilities, the motorized ball valve is also equipped with a manual switch, providing an added layer of assurance and peace of mind.\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFSV\/JFSV-smart-plug.jpg\"\u003e \u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFSV\/JFSV-smart-plug-p-1.jpg\"\u003e \u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFSV\/JFSV-smart-plug-p-2.jpg\"\u003e\u003c\/p\u003e\n\u003c!-- Features --\u003e\n\u003cdiv\u003e\n\u003ch2 class=\"section-title\"\u003eFeatures\u003c\/h2\u003e\n\u003cul class=\"section-description2\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eOpen Percentage:\u003c\/strong\u003e Set the open percentage for precise flow regulation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePlug Connection:\u003c\/strong\u003e Equipped with an included AC-DC adapter (converts AC 100V–240V to DC 5V) for direct wall outlet power supply.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFull Port:\u003c\/strong\u003e Maximum flow efficiency, zero restriction.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNormally Closed:\u003c\/strong\u003e Closed when unpowered, opens when energized.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNPT\/G Threading:\u003c\/strong\u003e NPT (National Pipe Taper) and G (BSPP) threading to accommodate diverse global specifications, ensuring a secure seal with \u003ca href=\"https:\/\/ussolid.com\/products\/u-s-solid-10-rolls-0-7-inch-w-x-905-inches-l-teflon-tape-plumbers-tape-yellow-shell-html?_pos=3\u0026amp;_sid=7aa2e2725\u0026amp;_ss=r\" target=\"_blank\"\u003eteflon tape\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eValve Body Material:\u003c\/strong\u003e Constructed from corrosion-resistant stainless steel and is NSF\/ANSI\/CAN 61 certified. Suitable for drinking water applications (compliant with standards).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePTFE Seal:\u003c\/strong\u003e Superior to NBR and Viton in sealing, temperature, and pressure resistance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFSV\/jfsv-smart-plug-ss.jpg\"\u003e \u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFSV\/jfsv-smart-plug-ss-p.jpg\"\u003e\u003c\/p\u003e\n\u003c!-- Technical Data --\u003e\n\u003ch2 class=\"section-title3\"\u003eTechnical Data\u003c\/h2\u003e\n\u003cdiv class=\"parameters-table-wrapper\"\u003e\n\u003ctable class=\"parameters-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eUSS-MSV00458\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eProduct Name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eSmart Motorized Ball Valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eBore Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eFull Port\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eLife Expectancy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e80,000-100,000 Cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eStatus Indicator\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eYes\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eFlow Aperture\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e40 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eThread Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eNPT\/G\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eOperating State\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eNormally Closed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eSize\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1-1\/2\"\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eWiring Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003ePlug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eValve Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eStainless Steel\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eBall Seal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003ePTFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eOperating Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e8-10 Seconds\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eWorking Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eConverts AC 100V–240V to DC 5V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eMax Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e5W\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eMax Torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e10 N·m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eMedium Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e32℉ to 194℉\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eAmbient Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-4℉ to 113℉\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eMax Medium Pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e145 PSI (1.0 Mpa)\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eCompatible Media\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eWater, air, oil and gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eGross Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e3.68 lbs\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003ePackage Dimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e8.66\"x3.94\"x5.31\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eUSB Cable Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2.1 m \/ 6.9 ft\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp class=\"section-description\"\u003e*To view the full table on mobile, please swipe left or right on the screen.\u003c\/p\u003e\n\u003c!-- User Manual --\u003e\n\n\u003ch2 class=\"section-title3\"\u003eCE Certified Quality \u0026amp; Safety\u003c\/h2\u003e\n\u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/CE\/CE.jpg\"\u003e\n\u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/CE\/CE.jpg\"\u003e\n\u003ch2 class=\"section-title\"\u003eUser Manual\u003c\/h2\u003e\n\u003cp class=\"section-description\"\u003eTo learn how to use this product, please refer to the \u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/Instruction%20Manual-U.S.%20Solid%20Smart%20Motorized%20Ball%20Valve2025.pdf\" target=\"_blank\"\u003euser manual\u003c\/a\u003e or watch the \u003ca href=\"https:\/\/youtu.be\/PfpgH29YU-s?list=TLGGw48OMJtyzq8yMTA3MjAyNQ\" target=\"_blank\"\u003etutorial video\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\u003cstrong\u003eNote:\u003c\/strong\u003eThe GIF demonstrates flow control by setting Open Percentage (100% = fully open, 0% = fully closed).\u003c\/p\u003e\n\u003cdiv class=\"instruction-container\"\u003e\n\u003cdiv class=\"img-container\"\u003e\u003cimg alt=\"\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif11.gif\" style=\"width: 100%; height: auto;\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"text-container\"\u003e\u003cimg alt=\"\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif12.gif\" style=\"width: 100%; height: auto;\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- FAQ --\u003e\n\u003ch2 class=\"section-title\"\u003eFAQ\u003c\/h2\u003e\n\u003cp class=\"faq\"\u003e\u003cb\u003eProblem 1: What's the difference between this series and the basic Smart Motorized Ball Valve model?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003eWhile the basic model operates on DC5V via USB, this series includes a plug adapter that converts AC100V-240V to DC5V for direct wall outlet connection.\u003c\/p\u003e\n\u003cp class=\"faq\"\u003e\u003cb\u003eProblem 2: Can the Smart Motorized Ball Valve only be controlled via the app?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\u003cstrong\u003eNo\u003c\/strong\u003e, it also features a manual push-button for local control.\u003c\/p\u003e\n\u003cp class=\"faq\"\u003e\u003cb\u003eProblem 3: This smart ball valve is marked as normally closed – can its power-off passage state be modified via the app?\u003c\/b\u003e\u003c\/p\u003e\n\u003cdiv class=\"instruction-container-faq\"\u003e\n\u003cdiv class=\"img-container-faq\"\u003e\u003cimg alt=\"\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFSV\/jfsv-smart-plug-off.jpg\" style=\"width: 100%; height: auto;\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"text-container-faq\"\u003e\n\u003cp class=\"section-title\"\u003eTap “Settings” to set\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003eThis smart ball valve is factory default set to a normally closed state (valve passage closes automatically when power is lost), and you can freely adjust its power-off working state according to your actual usage needs through the dedicated mobile app.\u003c\/p\u003e\n\u003cp class=\"section-title\"\u003eThree states\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003eSelect the specific power-off state you need for the valve, and the setting will be automatically saved immediately once you make your selection, no additional save operation is required.\u003c\/p\u003e\n\u003cul class=\"section-description2\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eOff:\u003c\/strong\u003e The valve passage stays closed when power is lost (consistent with the default setting).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOn:\u003c\/strong\u003e The valve passage remains open when power is lost.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMemory:\u003c\/strong\u003e The valve passage maintains its last working position before the power failure.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp class=\"faq\"\u003e\u003cb\u003eProblem 4: What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n\u003cul class=\"section-description2\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eFull Port:\u003c\/strong\u003e Matches pipe diameter, minimal flow restriction, ideal for high flow and low pressure drop.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard Port:\u003c\/strong\u003e Smaller than pipe diameter, higher resistance, suitable for general flow and pressure needs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"faq\"\u003e\u003cb\u003eProblem 5: Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\u003cstrong\u003eYes.\u003c\/strong\u003e This valve is made of food-grade stainless steel, meeting drinking water standards and is NSF\/ANSI\/CAN 61 certified. It is safe for potable water with no lead risk (unlike brass valves).\u003c\/p\u003e","brand":"U.S. Solid","offers":[{"title":"NPT","offer_id":47129099862271,"sku":"JFMSV00458","price":174.09,"currency_code":"USD","in_stock":true},{"title":"G","offer_id":47158151381247,"sku":"JFMSV00458-G","price":181.79,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/1_50d6fc9e-31d0-46c6-ba4a-1ad456b06f63.jpg?v=1755588938"},{"product_id":"wifi-2-stainless-steel-remote-control-motorized-ball-valve-with-power-off-memory-ac-100-240v-plug-adapter-with-dc-5v-output-manual-switch","title":"WiFi 2\" Stainless Steel Remote Control Motorized Ball Valve with Power-Off Memory, AC 100-240V Plug Adapter with DC 5V Output, Manual Switch","description":"\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e \u003cmeta content=\"width=device-width, initial-scale=1.0\" name=\"viewport\"\u003e\u003c\/p\u003e\n\u003cstyle\u003e\n        \n        .desktop-img {\n            display: block;\n        }\n        .mobile-img {\n            display: none;\n        } \n        \n        .section-title {\n            font-size: 22px;\n            line-height: 22px;\n            font-weight: bold;\n            margin: 15px 0 5px; \n            font-family: Arial;\n        }\n        \n        .section-title2 {\n            font-size: 22px;\n            line-height: 22px;\n            font-weight: bold;\n            margin: 15px 0 3px; \n            font-family: Arial;\n        }\n       \n        .section-title3 {\n            font-size: 22px;\n            line-height: 22px;\n            font-weight: bold;\n            margin: 15px 0 10px; \n            font-family: Arial;\n        }\n\n        \n        .section-description {\n            font-size: 16px;\n            line-height: 26px;\n            margin-top: 0px;\n            margin-bottom: 5px; \n            font-family: Arial;\n        }\n      \n        .faq {\n            font-size: 16px; \n            margin: 0; \n            line-height: 26px; \n            background-color: #f2f2f2; \n            padding: 5px;\n        }\n        \n        .section-description2 {\n            font-size: 16px;\n            line-height: 26px;\n            margin: 0px; \n            font-family: Arial;\n        }\n        \n.parameters-table-wrapper {\n    overflow-x: auto; \n    -webkit-overflow-scrolling: touch; \n    margin-top: 0px;\n}\n\n\n.parameters-table {\n    width: 100%;\n    min-width: 1000px;\n    border-collapse: collapse;\n    margin-top: 0px;\n}\n\n.parameters-table th, .parameters-table td {\n    border-top: 1.2px solid #a6a6a6; \n    border-bottom: 1.2px solid #a6a6a6;  \n    border-left: none;  \n    border-right: none;  \n    padding: 5px 2px;\n    text-align: left;\n    font-size: 16px;\n    line-height: 16px;\n}\n\n.parameters-table th {\n    background-color: #f2f2f2;\n    color: #2c2c2c;\n    font-weight: bold;\n}\n\n\n.parameters-table .bg-gray {\n    background-color: #f2f2f2;  \n}\n\n\n.options-table-wrapper {\n    overflow-x: auto; \n    -webkit-overflow-scrolling: touch; \n    margin-top: 0px;\n}\n\n.options-table {\n    width: 100%;\n    min-width: 1000px; \n    border-collapse: collapse;\n    margin-top: 0px;\n    box-shadow: 0 6px 25px rgba(0, 0, 0, 0.1); \n}\n\n.options-table th, .options-table td {\n    border: 2px solid #000;  \n    padding: 5px 2px;  \n    text-align: center;\n    font-size: 16px;\n    line-height: 16px;\n}\n\n.options-table th {\n    background-color: #f2f2f2;\n    color: #2c2c2c;\n    font-weight: bold;\n}\n\n\n.parameters-table2 {\n    width: 100%;\n    min-width: 1000px; \n    border-collapse: collapse;\n    margin-top: 0px;\n}\n\n.parameters-table2 th, .parameters-table2 td {\n    border-top: 1.2px solid #a6a6a6;  \n    border-bottom: 1.2px solid #a6a6a6; \n    border-left: none;  \n    border-right: none; \n    padding: 5px 2px;\n    text-align: center;\n    font-size: 16px;\n    line-height: 16px;\n}\n\n.parameters-table2 th {\n    background-color: #f2f2f2;\n    color: #2c2c2c;\n    font-weight: bold;\n}\n\n\n.parameters-table2 .bg-gray {\n    background-color: #f2f2f2;  \n}\n\n\n.options-table-wrapper2 {\n    overflow-x: auto; \n    -webkit-overflow-scrolling: touch; \n    margin-top: 0px;\n}\n\n        .instruction-container {\n             display: flex;\n             justify-content: space-between;\n             align-items: flex-start;\n             gap: 10px; \/* Adds space between the video and the text *\/\n             margin-bottom: 0px; \/* Adds some space below the section *\/\n        }\n\n      \n        .img-container {\n              width: 50%; \n             display: flex;\n             justify-content: center; \n        }\n\n      \n        .text-container {\n               width: 50%; \n             font-size: 16px;\n             font-family: Arial;\n             \n         }\n\n         .instruction-container2 {\n             display: flex;\n             justify-content: space-between;\n             align-items: flex-start;\n             gap: 10px; \/* Adds space between the video and the text *\/\n             margin-bottom: 0px; \/* Adds some space below the section *\/\n        }\n\n      \n        .img-container2 {\n             width: 50%; \n             display: flex;\n             justify-content: center; \n        }\n\n      \n        .text-container2 {\n             width: 50%; \n            display: flex;\n             justify-content: center;\n         }\n\n\n.instruction-container-faq {\n    display: flex;\n    justify-content: space-between;\n    align-items: flex-start;\n    gap: 10px;\n    margin-bottom: 0px;\n}\n.img-container-faq {\n    width: 35%; \n    display: flex;\n    justify-content: center;\n}\n.text-container-faq {\n    width: 65%; \n    font-size: 16px;\n    font-family: Arial;\n}\n\n@media (max-width: 768px) {\n    .instruction-container-faq {\n        flex-direction: column;\n        align-items: center;\n    }\n    .img-container-faq, .text-container-faq {\n        width: 100%;\n        margin-bottom: 0px;\n    }\n}\n\n@media (max-width: 768px) {\n    .parameters-table th, .parameters-table td {\n        font-size: 14px; \n        padding: 8px 4px; \n    }\n\n   \n    .options-table th, .options-table td {\n        font-size: 14px; \n        padding: 8px 4px;\n    }\n\n    .parameters-table-wrapper {\n        overflow-x: auto;\n    }\n    .parameters-table2 th, .parameters-table2 td {\n        font-size: 14px; \n        padding: 8px 4px; \n    }\n    .parameters-table-wrapper2 {\n        overflow-x: auto;\n    }\n    .desktop-img {\n                display: none;\n            }\n            .mobile-img {\n                display: block; \n            }\n    .instruction-container {\n                flex-direction: column; \n                align-items: center;\n            }\n\n            .img-container, .text-container {\n                width: 100%; \/* Both take full width *\/\n                margin-bottom: 0px; \n            }\n            .instruction-container2 {\n                flex-direction: column; \n                align-items: center;\n            }\n\n            .img-container2, .text-container2 {\n                width: 100%; \/* Both take full width *\/\n                margin-bottom: 0px; \n            }\n    \n}\n\n@media (max-width: 480px) {\n    .parameters-table th, .parameters-table td {\n        font-size: 12px; \n        padding: 6px 3px; \n    }\n\n    \n    .options-table th, .options-table td {\n        font-size: 12px; \n    }\n\n    .parameters-table-wrapper {\n        overflow-x: auto;\n    }\n    .parameters-table2 th, .parameters-table2 td {\n        font-size: 12px; \n        padding: 6px 3px; \n    }\n    .parameters-table-wrapper2 {\n        overflow-x: auto;\n    }\n    .desktop-img {\n                display: none; \n            }\n            .mobile-img {\n                display: block; \n            }\n    .instruction-container {\n                flex-direction: column; \n            }\n            .instruction-container2 {\n                flex-direction: column; \n            }\n    \n}\n    \u003c\/style\u003e\n\u003c!-- background --\u003e\n\u003cp\u003e\u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/jfmsv-WiFi-plug-a.jpg\"\u003e \u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/jfmsv-WiFi-plug-a-p.jpg\"\u003e\u003c\/p\u003e\n\u003c!-- Introduction --\u003e\n\u003cdiv\u003e\n\u003ch2 class=\"section-title\"\u003eIntroduction\u003c\/h2\u003e\n\u003cp class=\"section-description\"\u003eThe U.S. Solid Smart Motorized Ball Valve is a cutting-edge motorized ball valve with built-in smart control technology. Easily control the valve using your mobile device via Wi-Fi, with no complicated installation required. Simply download the app, connect to Wi-Fi, and remotely open or close the valve with a few taps. Enjoy unmatched convenience and ease of use compared to traditional valves. Perfect for controlling water, gas, or other fluids with reliable and accurate control every time.\u003cbr\u003eCompared to the basic model of smart motorized ball valve (powered by DC 5V via USB), this series comes with a plug-in AC-DC adapter that converts AC 100V-240V to DC 5V, enabling direct power supply from standard household AC outlets.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- Applications--\u003e\n\u003ch2 class=\"section-title2\"\u003eApplications\u003c\/h2\u003e\n\u003cp\u003e\u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFSV\/JFSV-smart-plug-a.jpg\"\u003e \u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFSV\/JFSV-a-p.jpg\"\u003e\u003c\/p\u003e\n\u003c!-- Smart Control--\u003e\n\u003ch2 class=\"section-title2\"\u003eSmart Control\u003c\/h2\u003e\n\u003cp class=\"section-description\"\u003eThe smart motorized ball valve features a smart-control function, providing you with the convenience of controlling your valve using your cellphone. Furthermore, once the valve is connected to your WiFi, you can remotely control the valve even when you are away from home.\u003cbr\u003eThis feature allows for seamless and convenient operation of the valve from anywhere at any time.In addition to its smart control capabilities, the motorized ball valve is also equipped with a manual switch, providing an added layer of assurance and peace of mind.\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFSV\/JFSV-smart-plug.jpg\"\u003e \u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFSV\/JFSV-smart-plug-p-1.jpg\"\u003e \u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFSV\/JFSV-smart-plug-p-2.jpg\"\u003e\u003c\/p\u003e\n\u003c!-- Features --\u003e\n\u003cdiv\u003e\n\u003ch2 class=\"section-title\"\u003eFeatures\u003c\/h2\u003e\n\u003cul class=\"section-description2\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eOpen Percentage:\u003c\/strong\u003e Set the open percentage for precise flow regulation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePlug Connection:\u003c\/strong\u003e Equipped with an included AC-DC adapter (converts AC 100V–240V to DC 5V) for direct wall outlet power supply.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFull Port:\u003c\/strong\u003e Maximum flow efficiency, zero restriction.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNormally Closed:\u003c\/strong\u003e Closed when unpowered, opens when energized.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNPT\/G Threading:\u003c\/strong\u003e NPT (National Pipe Taper) and G (BSPP) threading to accommodate diverse global specifications, ensuring a secure seal with \u003ca href=\"https:\/\/ussolid.com\/products\/u-s-solid-10-rolls-0-7-inch-w-x-905-inches-l-teflon-tape-plumbers-tape-yellow-shell-html?_pos=3\u0026amp;_sid=7aa2e2725\u0026amp;_ss=r\" target=\"_blank\"\u003eteflon tape\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eValve Body Material:\u003c\/strong\u003e Constructed from corrosion-resistant stainless steel and is NSF\/ANSI\/CAN 61 certified. Suitable for drinking water applications (compliant with standards).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePTFE Seal:\u003c\/strong\u003e Superior to NBR and Viton in sealing, temperature, and pressure resistance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFSV\/jfsv-smart-plug-ss.jpg\"\u003e \u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFSV\/jfsv-smart-plug-ss-p.jpg\"\u003e\u003c\/p\u003e\n\u003c!-- Technical Data --\u003e\n\u003ch2 class=\"section-title3\"\u003eTechnical Data\u003c\/h2\u003e\n\u003cdiv class=\"parameters-table-wrapper\"\u003e\n\u003ctable class=\"parameters-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eUSS-MSV00459\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eProduct Name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eSmart Motorized Ball Valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eBore Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eFull Port\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eLife Expectancy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e80,000-100,000 Cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eStatus Indicator\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eYes\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eFlow Aperture\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eThread Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eNPT\/G\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eOperating State\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eNormally Closed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eSize\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2\"\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eWiring Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003ePlug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eValve Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eStainless Steel\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eBall Seal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003ePTFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eOperating Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e8-10 Seconds\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eWorking Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eConverts AC 100V–240V to DC 5V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eMax Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e5W\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eMax Torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e10 N·m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eMedium Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e32℉ to 194℉\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eAmbient Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-4℉ to 113℉\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eMax Medium Pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e145 PSI (1.0 Mpa)\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eCompatible Media\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eWater, air, oil and gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eGross Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e4.87 lbs\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003ePackage Dimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e8.07\"x3.94\"x5.71\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eUSB Cable Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2.1 m \/ 6.9 ft\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp class=\"section-description\"\u003e*To view the full table on mobile, please swipe left or right on the screen.\u003c\/p\u003e\n\u003c!-- User Manual --\u003e\n\n\u003ch2 class=\"section-title3\"\u003eCE Certified Quality \u0026amp; Safety\u003c\/h2\u003e\n\u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/CE\/CE.jpg\"\u003e\n\u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/CE\/CE.jpg\"\u003e\n\u003ch2 class=\"section-title\"\u003eUser Manual\u003c\/h2\u003e\n\u003cp class=\"section-description\"\u003eTo learn how to use this product, please refer to the \u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/Instruction%20Manual-U.S.%20Solid%20Smart%20Motorized%20Ball%20Valve2025.pdf\" target=\"_blank\"\u003euser manual\u003c\/a\u003e or watch the \u003ca href=\"https:\/\/youtu.be\/PfpgH29YU-s?list=TLGGw48OMJtyzq8yMTA3MjAyNQ\" target=\"_blank\"\u003etutorial video\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\u003cstrong\u003eNote:\u003c\/strong\u003eThe GIF demonstrates flow control by setting Open Percentage (100% = fully open, 0% = fully closed).\u003c\/p\u003e\n\u003cdiv class=\"instruction-container\"\u003e\n\u003cdiv class=\"img-container\"\u003e\u003cimg alt=\"\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif11.gif\" style=\"width: 100%; height: auto;\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"text-container\"\u003e\u003cimg alt=\"\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif12.gif\" style=\"width: 100%; height: auto;\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- FAQ --\u003e\n\u003ch2 class=\"section-title\"\u003eFAQ\u003c\/h2\u003e\n\u003cp class=\"faq\"\u003e\u003cb\u003eProblem 1: What's the difference between this series and the basic Smart Motorized Ball Valve model?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003eWhile the basic model operates on DC5V via USB, this series includes a plug adapter that converts AC100V-240V to DC5V for direct wall outlet connection.\u003c\/p\u003e\n\u003cp class=\"faq\"\u003e\u003cb\u003eProblem 2: Can the Smart Motorized Ball Valve only be controlled via the app?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\u003cstrong\u003eNo\u003c\/strong\u003e, it also features a manual push-button for local control.\u003c\/p\u003e\n\u003cp class=\"faq\"\u003e\u003cb\u003eProblem 3: This smart ball valve is marked as normally closed – can its power-off passage state be modified via the app?\u003c\/b\u003e\u003c\/p\u003e\n\u003cdiv class=\"instruction-container-faq\"\u003e\n\u003cdiv class=\"img-container-faq\"\u003e\u003cimg alt=\"\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFSV\/jfsv-smart-plug-off.jpg\" style=\"width: 100%; height: auto;\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"text-container-faq\"\u003e\n\u003cp class=\"section-title\"\u003eTap “Settings” to set\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003eThis smart ball valve is factory default set to a normally closed state (valve passage closes automatically when power is lost), and you can freely adjust its power-off working state according to your actual usage needs through the dedicated mobile app.\u003c\/p\u003e\n\u003cp class=\"section-title\"\u003eThree states\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003eSelect the specific power-off state you need for the valve, and the setting will be automatically saved immediately once you make your selection, no additional save operation is required.\u003c\/p\u003e\n\u003cul class=\"section-description2\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eOff:\u003c\/strong\u003e The valve passage stays closed when power is lost (consistent with the default setting).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOn:\u003c\/strong\u003e The valve passage remains open when power is lost.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMemory:\u003c\/strong\u003e The valve passage maintains its last working position before the power failure.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp class=\"faq\"\u003e\u003cb\u003eProblem 4: What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n\u003cul class=\"section-description2\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eFull Port:\u003c\/strong\u003e Matches pipe diameter, minimal flow restriction, ideal for high flow and low pressure drop.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard Port:\u003c\/strong\u003e Smaller than pipe diameter, higher resistance, suitable for general flow and pressure needs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"faq\"\u003e\u003cb\u003eProblem 5: Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\u003cstrong\u003eYes.\u003c\/strong\u003e This valve is made of food-grade stainless steel, meeting drinking water standards and is NSF\/ANSI\/CAN 61 certified. It is safe for potable water with no lead risk (unlike brass valves).\u003c\/p\u003e","brand":"U.S. Solid","offers":[{"title":"NPT","offer_id":47129101271295,"sku":"JFMSV00459","price":224.09,"currency_code":"USD","in_stock":true},{"title":"G","offer_id":47158162260223,"sku":"JFMSV00459-G","price":220.68,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/2_641d291c-4774-4ba3-b8ae-19d7aacadd7d.jpg?v=1755589116"},{"product_id":"3-4-ss316-motorized-ball-valve-with-waterproof-cover-110-230v-ac-full-port-ip67-2-wire-auto-return-normally-closed","title":"3\/4\" SS316 Motorized Ball Valve with Waterproof Cover, 110-230V AC, Full Port, IP67, 2 Wire Auto Return, Normally Closed","description":"\u003cbody\u003e     \n\n\n        \u003cstyle\u003e\n            @media only screen and (max-width: 600px) {\n            }\n        \u003c\/style\u003e\n\n\n        \u003cdiv class=\"desktop-only\"\u003e\n           \n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n            \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; line-height: 26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 10px; color: black; font-family: Arial;\"\u003eMotorized ball valves are a vital piece of equipment in numerous applications. This model opens and closes in 3-5 seconds, and remains in its new position while expending almost no energy. This is a key difference between motorized ball valves and many solenoid valves. Most solenoid valves are energized continuously when in a new position, while motorized ball valves expend energy only when changing from open to close, or vice versa.\u003cbr\u003eThe 2 wire auto return model is perfect for situations where the valve needs to be closed in case of power loss. The valve can be energized to open, and left hooked up, with negligible energy used once fully opened. To close, simply shutoff power to the valve. This valve is convenient because it can be operated with a simple on off switch. When on, it will remain open, when turned off (or power is lost for some other reason) the valve automatically closes.\u003c\/p\u003e\n            \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n                 \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/features-JFMSV3.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                    \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                 \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n                 \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse;\n                      border: 0px;\n                      width: 100%;\n                      font-family: Arial;\n                      overflow-x: auto;\n                      background-color: #FFFFFF;\"\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"width: 100%;text-align: left;\n                           padding: 0px;\n                           font-size: 16px;\n                           border: 0;\n                           background-color: #FFFFFF;\"\u003e\n                    \u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n                    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 1\" style=\"width: 100%;height: 100%;\"\u003e\n                \u003c\/td\u003e\n                \u003ctd style=\"width: 100%;text-align: left;\n                           padding: 0px;\n                           font-size: 16px;\n                           border: 0;\n                           background-color: #FFFFFF;\"\u003e\n                    \u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n                    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 2\" style=\"width: 100%;height: 100%;\"\u003e\n                \u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n              \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n    \u003c\/div\u003e \n     \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n            \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n                \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                    \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                    \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV30025\u003c\/td\u003e\n                    \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n                    \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eU.S. Solid\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                    \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                    \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e3\/4\"\u003c\/td\u003e\n                    \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                    \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e2 Wire Auto Return\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                    \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                    \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eSS316\u003c\/td\u003e\n                    \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                    \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eIP67\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                    \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                    \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e3 - 5 Seconds\u003c\/td\u003e\n                    \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                    \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e110 - 230V AC\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                    \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                    \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e5 W\u003c\/td\u003e\n                    \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                    \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e2 N m\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                    \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                    \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                    \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                    \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e2°C to 90°C\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                    \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                    \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e70,000 Cycles\u003c\/td\u003e\n                    \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                    \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eFull\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                    \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                    \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\u003c\/td\u003e\n                    \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n                    \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNormally Closed\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                    \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e-15°C to 55°C\u003c\/td\u003e\n                    \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                    \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/table\u003e\n        \u003c\/div\u003e\n        \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/CE\/CE.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP67 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYES. The motorized ball valve is made of lead-free stainless steel.\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n        \u003c\/div\u003e\n           \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                    \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                    \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                    \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n                   \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n                   \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP67 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n                   \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n                \u003c\/div\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n         \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n         \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n         \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n         \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n         \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n         \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n         \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP67. The 6 in IP67 represents complete dust - tightness. The 7 in IP67 indicates protection against water immersion up to 1 meter for 30 minutes. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n         \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/IP67-SS304.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n     \u003cdiv style=\"text-align: left;\"\u003e\n      \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/Manual%20for%20Tonhe.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n    \u003c\/div\u003e\n        \u003c\/div\u003e\n        \u003cdiv class=\"mobile-only\"\u003e\n            \n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; line-height:26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 0px; color: black; font-family: Arial;\"\u003eMotorized ball valves are a vital piece of equipment in numerous applications. This model opens and closes in 3-5 seconds, and remains in its new position while expending almost no energy. This is a key difference between motorized ball valves and many solenoid valves. Most solenoid valves are energized continuously when in a new position, while motorized ball valves expend energy only when changing from open to close, or vice versa.\u003cbr\u003eThe 2 wire auto return model is perfect for situations where the valve needs to be closed in case of power loss. The valve can be energized to open, and left hooked up, with negligible energy used once fully opened. To close, simply shutoff power to the valve. This valve is convenient because it can be operated with a simple on off switch. When on, it will remain open, when turned off (or power is lost for some other reason) the valve automatically closes.\u003c\/p\u003e\n                \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n                    \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/features-JFMSV3.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                    \u003cp style=\"font-size: 22px; text-align: left; margin-bottom:10px; margin-top:20px; color: black;\"\u003e\u003cstrong\u003eAPPLICATION\u003c\/strong\u003e\u003c\/p\u003e\n    \u003c\/div\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                 \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n                \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 1\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n        \u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 2\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n    \u003c\/div\u003e\n          \u003cp style=\"font-size: 16px; text-align: left; margin-bottom:10px; margin-top:20px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n           \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n            \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n                \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                    \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                    \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV30025\u003c\/td\u003e\n                    \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n                    \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eU.S. Solid\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                    \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                    \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e3\/4\"\u003c\/td\u003e\n                    \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                    \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e2 Wire Auto Return\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                    \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                    \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eSS316\u003c\/td\u003e\n                    \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                    \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eIP67\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                    \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                    \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e3 - 5 Seconds\u003c\/td\u003e\n                    \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                    \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e110 - 230V AC\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                    \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                    \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e5 W\u003c\/td\u003e\n                    \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                    \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e2 N m\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                    \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                    \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                    \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                    \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e2°C to 90°C\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                    \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                    \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e70,000 Cycles\u003c\/td\u003e\n                    \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                    \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eFull\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                    \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                    \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\u003c\/td\u003e\n                    \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n                    \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNormally Closed\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                    \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e-15°C to 55°C\u003c\/td\u003e\n                    \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                    \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/table\u003e\n        \u003c\/div\u003e\n        \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/CE\/CE.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n           \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP67 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYES. The motorized ball valve is made of lead-free stainless steel.\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n        \u003c\/div\u003e\n           \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                    \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                    \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n                   \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n                   \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP67 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n                   \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n                \u003c\/div\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n         \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n         \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n         \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n         \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n         \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n         \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n         \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP67. The 6 in IP67 represents complete dust - tightness. The 7 in IP67 indicates protection against water immersion up to 1 meter for 30 minutes. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n         \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/IP67-SS304.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                 \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n      \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/Manual%20for%20Tonhe.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n    \u003c\/div\u003e\n    \u003c\/div\u003e\n        \u003cscript\u003e\n           \n            const isMobile = window.matchMedia(\"only screen and (max-width: 600px)\").matches;\n            const desktopContent = document.querySelector('.desktop-only');\n            const mobileContent = document.querySelector('.mobile-only');\n\n            if (isMobile) {\n                \n                console.log('The user is accessing from a mobile phone or tablet device.');\n                \n                desktopContent.style.display = 'none';\n                mobileContent.style.display = 'block';\n            } else {\n                \n                console.log('The user is accessing from a desktop device.');            \n                \n                desktopContent.style.display = 'block';\n                mobileContent.style.display = 'none';\n            }\n        \u003c\/script\u003e\n\n\n\n    \u003c\/body\u003e","brand":"U.S. Solid","offers":[{"title":"NPT","offer_id":47613686219007,"sku":"JFMSV30025","price":95.84,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/image_1_4e033f0f-e12f-4acd-adc7-1ac309d39659.jpg?v=1769589335"},{"product_id":"1-2-ss316-motorized-ball-valve-with-waterproof-cover-110-230v-ac-full-port-ip67-2-wire-auto-return-normally-closed","title":"1\/2\" SS316 Motorized Ball Valve with Waterproof Cover, 110-230V AC, Full Port, IP67, 2 Wire Auto Return, Normally Closed","description":"\u003cbody\u003e     \n\n\n        \u003cstyle\u003e\n            @media only screen and (max-width: 600px) {\n            }\n        \u003c\/style\u003e\n\n\n        \u003cdiv class=\"desktop-only\"\u003e\n           \n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n            \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; line-height: 26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 10px; color: black; font-family: Arial;\"\u003eMotorized ball valves are a vital piece of equipment in numerous applications. This model opens and closes in 3-5 seconds, and remains in its new position while expending almost no energy. This is a key difference between motorized ball valves and many solenoid valves. Most solenoid valves are energized continuously when in a new position, while motorized ball valves expend energy only when changing from open to close, or vice versa.\u003cbr\u003eThe 2 wire auto return model is perfect for situations where the valve needs to be closed in case of power loss. The valve can be energized to open, and left hooked up, with negligible energy used once fully opened. To close, simply shutoff power to the valve. This valve is convenient because it can be operated with a simple on off switch. When on, it will remain open, when turned off (or power is lost for some other reason) the valve automatically closes.\u003c\/p\u003e\n            \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n                 \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/features-JFMSV3.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                    \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                 \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n                 \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse;\n                      border: 0px;\n                      width: 100%;\n                      font-family: Arial;\n                      overflow-x: auto;\n                      background-color: #FFFFFF;\"\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"width: 100%;text-align: left;\n                           padding: 0px;\n                           font-size: 16px;\n                           border: 0;\n                           background-color: #FFFFFF;\"\u003e\n                    \u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n                    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 1\" style=\"width: 100%;height: 100%;\"\u003e\n                \u003c\/td\u003e\n                \u003ctd style=\"width: 100%;text-align: left;\n                           padding: 0px;\n                           font-size: 16px;\n                           border: 0;\n                           background-color: #FFFFFF;\"\u003e\n                    \u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n                    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 2\" style=\"width: 100%;height: 100%;\"\u003e\n                \u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n              \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n    \u003c\/div\u003e \n     \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n            \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n                \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                    \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                    \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV30024\u003c\/td\u003e\n                    \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n                    \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eU.S. Solid\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                    \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                    \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1\/2\"\u003c\/td\u003e\n                    \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                    \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e2 Wire Auto Return\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                    \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                    \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eSS316\u003c\/td\u003e\n                    \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                    \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eIP67\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                    \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                    \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e3 - 5 Seconds\u003c\/td\u003e\n                    \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                    \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e110 - 230V AC\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                    \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                    \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e5 W\u003c\/td\u003e\n                    \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                    \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e2 N m\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                    \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                    \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                    \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                    \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e2°C to 90°C\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                    \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                    \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e70,000 Cycles\u003c\/td\u003e\n                    \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                    \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eFull\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                    \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                    \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\u003c\/td\u003e\n                    \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n                    \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNormally Closed\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                    \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e-15°C to 55°C\u003c\/td\u003e\n                    \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                    \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/table\u003e\n        \u003c\/div\u003e\n        \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/CE\/CE.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP67 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYES. The motorized ball valve is made of lead-free stainless steel.\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n        \u003c\/div\u003e\n           \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                    \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                    \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                    \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n                   \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n                   \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP67 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n                   \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n                \u003c\/div\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n         \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n         \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n         \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n         \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n         \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n         \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n         \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP67. The 6 in IP67 represents complete dust - tightness. The 7 in IP67 indicates protection against water immersion up to 1 meter for 30 minutes. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n         \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/IP67-SS304.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n     \u003cdiv style=\"text-align: left;\"\u003e\n      \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/Manual%20for%20Tonhe.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n    \u003c\/div\u003e\n        \u003c\/div\u003e\n        \u003cdiv class=\"mobile-only\"\u003e\n            \n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; line-height:26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 0px; color: black; font-family: Arial;\"\u003eMotorized ball valves are a vital piece of equipment in numerous applications. This model opens and closes in 3-5 seconds, and remains in its new position while expending almost no energy. This is a key difference between motorized ball valves and many solenoid valves. Most solenoid valves are energized continuously when in a new position, while motorized ball valves expend energy only when changing from open to close, or vice versa.\u003cbr\u003eThe 2 wire auto return model is perfect for situations where the valve needs to be closed in case of power loss. The valve can be energized to open, and left hooked up, with negligible energy used once fully opened. To close, simply shutoff power to the valve. This valve is convenient because it can be operated with a simple on off switch. When on, it will remain open, when turned off (or power is lost for some other reason) the valve automatically closes.\u003c\/p\u003e\n                \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n                    \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/features-JFMSV3.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                    \u003cp style=\"font-size: 22px; text-align: left; margin-bottom:10px; margin-top:20px; color: black;\"\u003e\u003cstrong\u003eAPPLICATION\u003c\/strong\u003e\u003c\/p\u003e\n    \u003c\/div\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                 \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n                \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 1\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n        \u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 2\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n    \u003c\/div\u003e\n          \u003cp style=\"font-size: 16px; text-align: left; margin-bottom:10px; margin-top:20px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n           \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n            \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n                \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                    \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                    \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV30024\u003c\/td\u003e\n                    \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n                    \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eU.S. Solid\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                    \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                    \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1\/2\"\u003c\/td\u003e\n                    \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                    \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e2 Wire Auto Return\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                    \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                    \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eSS316\u003c\/td\u003e\n                    \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                    \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eIP67\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                    \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                    \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e3 - 5 Seconds\u003c\/td\u003e\n                    \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                    \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e110 - 230V AC\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                    \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                    \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e5 W\u003c\/td\u003e\n                    \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                    \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e2 N m\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                    \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                    \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                    \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                    \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e2°C to 90°C\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                    \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                    \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e70,000 Cycles\u003c\/td\u003e\n                    \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                    \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eFull\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                    \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                    \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\u003c\/td\u003e\n                    \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n                    \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNormally Closed\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                    \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e-15°C to 55°C\u003c\/td\u003e\n                    \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                    \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/table\u003e\n        \u003c\/div\u003e\n        \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/CE\/CE.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n           \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP67 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYES. The motorized ball valve is made of lead-free stainless steel.\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n        \u003c\/div\u003e\n           \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                    \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                    \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n                   \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n                   \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP67 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n                   \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n                \u003c\/div\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n         \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n         \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n         \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n         \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n         \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n         \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n         \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP67. The 6 in IP67 represents complete dust - tightness. The 7 in IP67 indicates protection against water immersion up to 1 meter for 30 minutes. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n         \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/IP67-SS304.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                 \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n      \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/Manual%20for%20Tonhe.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n    \u003c\/div\u003e\n    \u003c\/div\u003e\n        \u003cscript\u003e\n           \n            const isMobile = window.matchMedia(\"only screen and (max-width: 600px)\").matches;\n            const desktopContent = document.querySelector('.desktop-only');\n            const mobileContent = document.querySelector('.mobile-only');\n\n            if (isMobile) {\n                \n                console.log('The user is accessing from a mobile phone or tablet device.');\n                \n                desktopContent.style.display = 'none';\n                mobileContent.style.display = 'block';\n            } else {\n                \n                console.log('The user is accessing from a desktop device.');            \n                \n                desktopContent.style.display = 'block';\n                mobileContent.style.display = 'none';\n            }\n        \u003c\/script\u003e\n\n\n\n    \u003c\/body\u003e","brand":"U.S. Solid","offers":[{"title":"NPT","offer_id":47613697589503,"sku":"JFMSV30024","price":84.35,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/image_1_1a568208-00b8-4719-9acc-2802f6197691.jpg?v=1769589192"},{"product_id":"1-ss316-motorized-ball-valve-with-waterproof-cover-110-230v-ac-full-port-ip67-2-wire-auto-return-normally-closed","title":"1\" SS316 Motorized Ball Valve with Waterproof Cover, 110-230V AC, Full Port, IP67, 2 Wire Auto Return, Normally Closed","description":"\u003cbody\u003e     \n\n\n        \u003cstyle\u003e\n            @media only screen and (max-width: 600px) {\n            }\n        \u003c\/style\u003e\n\n\n        \u003cdiv class=\"desktop-only\"\u003e\n           \n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n            \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; line-height: 26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 10px; color: black; font-family: Arial;\"\u003eMotorized ball valves are a vital piece of equipment in numerous applications. This model opens and closes in 3-5 seconds, and remains in its new position while expending almost no energy. This is a key difference between motorized ball valves and many solenoid valves. Most solenoid valves are energized continuously when in a new position, while motorized ball valves expend energy only when changing from open to close, or vice versa.\u003cbr\u003eThe 2 wire auto return model is perfect for situations where the valve needs to be closed in case of power loss. The valve can be energized to open, and left hooked up, with negligible energy used once fully opened. To close, simply shutoff power to the valve. This valve is convenient because it can be operated with a simple on off switch. When on, it will remain open, when turned off (or power is lost for some other reason) the valve automatically closes.\u003c\/p\u003e\n            \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n                 \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/features-JFMSV3.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                    \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                 \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n                 \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse;\n                      border: 0px;\n                      width: 100%;\n                      font-family: Arial;\n                      overflow-x: auto;\n                      background-color: #FFFFFF;\"\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"width: 100%;text-align: left;\n                           padding: 0px;\n                           font-size: 16px;\n                           border: 0;\n                           background-color: #FFFFFF;\"\u003e\n                    \u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n                    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 1\" style=\"width: 100%;height: 100%;\"\u003e\n                \u003c\/td\u003e\n                \u003ctd style=\"width: 100%;text-align: left;\n                           padding: 0px;\n                           font-size: 16px;\n                           border: 0;\n                           background-color: #FFFFFF;\"\u003e\n                    \u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n                    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 2\" style=\"width: 100%;height: 100%;\"\u003e\n                \u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n              \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n    \u003c\/div\u003e \n     \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n            \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n                \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                    \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                    \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV30026\u003c\/td\u003e\n                    \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n                    \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eU.S. Solid\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                    \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                    \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1\"\u003c\/td\u003e\n                    \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                    \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e2 Wire Auto Return\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                    \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                    \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eSS316\u003c\/td\u003e\n                    \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                    \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eIP67\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                    \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                    \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e3 - 5 Seconds\u003c\/td\u003e\n                    \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                    \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e110 - 230V AC\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                    \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                    \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e5 W\u003c\/td\u003e\n                    \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                    \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e2 N m\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                    \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                    \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                    \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                    \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e2°C to 90°C\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                    \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                    \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e70,000 Cycles\u003c\/td\u003e\n                    \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                    \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eFull\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                    \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                    \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\u003c\/td\u003e\n                    \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n                    \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNormally Closed\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                    \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e-15°C to 55°C\u003c\/td\u003e\n                    \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                    \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/table\u003e\n        \u003c\/div\u003e\n        \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/CE\/CE.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP67 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYES. The motorized ball valve is made of lead-free stainless steel.\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n        \u003c\/div\u003e\n           \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                    \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                    \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                    \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n                   \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n                   \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP67 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n                   \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n                \u003c\/div\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n         \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n         \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n         \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n         \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n         \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n         \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n         \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP67. The 6 in IP67 represents complete dust - tightness. The 7 in IP67 indicates protection against water immersion up to 1 meter for 30 minutes. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n         \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/IP67-SS304.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n     \u003cdiv style=\"text-align: left;\"\u003e\n      \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/Manual%20for%20Tonhe.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n    \u003c\/div\u003e\n        \u003c\/div\u003e\n        \u003cdiv class=\"mobile-only\"\u003e\n            \n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; line-height:26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 0px; color: black; font-family: Arial;\"\u003eMotorized ball valves are a vital piece of equipment in numerous applications. This model opens and closes in 3-5 seconds, and remains in its new position while expending almost no energy. This is a key difference between motorized ball valves and many solenoid valves. Most solenoid valves are energized continuously when in a new position, while motorized ball valves expend energy only when changing from open to close, or vice versa.\u003cbr\u003eThe 2 wire auto return model is perfect for situations where the valve needs to be closed in case of power loss. The valve can be energized to open, and left hooked up, with negligible energy used once fully opened. To close, simply shutoff power to the valve. This valve is convenient because it can be operated with a simple on off switch. When on, it will remain open, when turned off (or power is lost for some other reason) the valve automatically closes.\u003c\/p\u003e\n                \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n                    \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/features-JFMSV3.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                    \u003cp style=\"font-size: 22px; text-align: left; margin-bottom:10px; margin-top:20px; color: black;\"\u003e\u003cstrong\u003eAPPLICATION\u003c\/strong\u003e\u003c\/p\u003e\n    \u003c\/div\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                 \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n                \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 1\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n        \u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 2\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n    \u003c\/div\u003e\n          \u003cp style=\"font-size: 16px; text-align: left; margin-bottom:10px; margin-top:20px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n           \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n            \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n                \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                    \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                    \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV30026\u003c\/td\u003e\n                    \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n                    \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eU.S. Solid\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                    \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                    \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1\"\u003c\/td\u003e\n                    \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                    \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e2 Wire Auto Return\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                    \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                    \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eSS316\u003c\/td\u003e\n                    \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                    \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eIP67\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                    \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                    \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e3 - 5 Seconds\u003c\/td\u003e\n                    \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                    \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e110 - 230V AC\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                    \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                    \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e5 W\u003c\/td\u003e\n                    \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                    \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e2 N m\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                    \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                    \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                    \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                    \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e2°C to 90°C\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                    \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                    \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e70,000 Cycles\u003c\/td\u003e\n                    \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                    \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eFull\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                    \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                    \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\u003c\/td\u003e\n                    \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n                    \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNormally Closed\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                    \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e-15°C to 55°C\u003c\/td\u003e\n                    \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                    \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/table\u003e\n        \u003c\/div\u003e\n        \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/CE\/CE.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n           \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP67 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYES. The motorized ball valve is made of lead-free stainless steel.\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n        \u003c\/div\u003e\n           \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                    \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                    \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n                   \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n                   \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP67 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n                   \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n                \u003c\/div\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n         \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n         \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n         \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n         \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n         \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n         \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n         \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP67. The 6 in IP67 represents complete dust - tightness. The 7 in IP67 indicates protection against water immersion up to 1 meter for 30 minutes. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n         \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/IP67-SS304.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                 \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n      \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/Manual%20for%20Tonhe.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n    \u003c\/div\u003e\n    \u003c\/div\u003e\n        \u003cscript\u003e\n           \n            const isMobile = window.matchMedia(\"only screen and (max-width: 600px)\").matches;\n            const desktopContent = document.querySelector('.desktop-only');\n            const mobileContent = document.querySelector('.mobile-only');\n\n            if (isMobile) {\n                \n                console.log('The user is accessing from a mobile phone or tablet device.');\n                \n                desktopContent.style.display = 'none';\n                mobileContent.style.display = 'block';\n            } else {\n                \n                console.log('The user is accessing from a desktop device.');            \n                \n                desktopContent.style.display = 'block';\n                mobileContent.style.display = 'none';\n            }\n        \u003c\/script\u003e\n\n\n\n    \u003c\/body\u003e","brand":"U.S. Solid","offers":[{"title":"NPT","offer_id":47613764665599,"sku":"JFMSV30026","price":99.84,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/image_1_95255efd-6acf-4ebb-9778-2282b3bd1ab0.jpg?v=1769589369"},{"product_id":"motorized-ball-valve-ip67-12-stainless-steel-waterproof-full-port-110-230v-ac-2-wire-auto-return-normally-open","title":"Motorized Ball Valve - IP67 1\/2\" Stainless Steel, Waterproof, Full Port, 110-230V AC, 2 Wire Auto Return, Normally Open","description":"\u003cbody\u003e\n\u003cstyle\u003e\n        @media only screen and (max-width: 600px) {\n        }\n    \u003c\/style\u003e\n\u003cdiv class=\"desktop-only\"\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top: 0px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; line-height: 26px; color: black; font-family: Arial; margin: 10px 0px 0px 0px;\"\u003eMotorized ball valves are a vital piece of equipment in numerous applications. This model opens and closes in 3-5 seconds, and remains in its new position while expending almost no energy. This is a key difference between motorized ball valves and many solenoid valves. Most solenoid valves are energized continuously when in a new position, while motorized ball valves expend energy only when changing from open to close, or vice versa.\u003cbr\u003eThe 2-wire auto-return model is perfect for situations where the valve needs to remain open in the event of power loss. The valve can be energized to close and, once fully closed, consumes negligible energy. To open the valve, simply shut off power. This valve is convenient because it can be operated with a simple on\/off switch: when powered on, it remains closed; when turned off—or if power is lost for any reason—the valve automatically opens.\u003c\/p\u003e\n\u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/features-JFMSV3.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n\u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #ffffff;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 0px; font-size: 16px; border: 0; background-color: #ffffff;\"\u003e\n\u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 1\/2\" style=\"width: 100%; height: 100%;\"\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 0px; font-size: 16px; border: 0; background-color: #ffffff;\"\u003e\n\u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 2\" style=\"width: 100%; height: 100%;\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n\u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #ffffff;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003eUSS-MSV50004\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003eU.S. Solid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003e1\/2\"\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003e2 Wire Auto Return\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003eSS304\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003eIP67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003e3 - 5 Seconds\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003e110- 230V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003e5 W\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003e2 N m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003e1.0 Mpa\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003e2°C to 90°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003e70,000 Cycles\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003eFull\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003eNPT\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003eNormally Open\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003e-15°C to 55°C\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003ePTFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial; line-height: 26px;\"\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eThe motor's housing is rated at IP67 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eYES. The motorized ball valve is made of lead-free stainless steel.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial; line-height: 26px;\"\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top: 20px; margin-bottom: 10px; line-height: 26px; color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP67 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eThe valves have an ingress - protection rating of IP67. The 6 in IP67 represents complete dust - tightness. The 7 in IP67 indicates protection against water immersion up to 1 meter for 30 minutes. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/IP67-SS304.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/Manual%20for%20Tonhe.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mobile-only\"\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top: 0px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; line-height: 26px; color: black; font-family: Arial; margin: 0px;\"\u003eMotorized ball valves are a vital piece of equipment in numerous applications. This model opens and closes in 3-5 seconds, and remains in its new position while expending almost no energy. This is a key difference between motorized ball valves and many solenoid valves. Most solenoid valves are energized continuously when in a new position, while motorized ball valves expend energy only when changing from open to close, or vice versa.\u003cbr\u003eThe 2-wire auto-return model is perfect for situations where the valve needs to remain open in the event of power loss. The valve can be energized to close and, once fully closed, consumes negligible energy. To open the valve, simply shut off power. This valve is convenient because it can be operated with a simple on\/off switch: when powered on, it remains closed; when turned off—or if power is lost for any reason—the valve automatically opens.\u003c\/p\u003e\n\u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/features-JFMSV3.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-bottom: 10px; margin-top: 20px; color: black;\"\u003e\u003cstrong\u003eAPPLICATION\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n\u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 1\/2\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n\u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 2\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 16px; text-align: left; margin-bottom: 10px; margin-top: 20px; color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n\u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #ffffff;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003eUSS-MSV50004\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003eU.S. Solid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003e1\/2\"\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003e2 Wire Auto Return\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003eSS304\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003eIP67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003e3 - 5 Seconds\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003e110- 230V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003e5 W\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003e2 N m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003e1.0 Mpa\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003e2°C to 90°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003e70,000 Cycles\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003eFull\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003eNPT\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003eNormally Open\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003e-15°C to 55°C\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003ePTFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial; line-height: 26px;\"\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eThe motor's housing is rated at IP67 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eYES. The motorized ball valve is made of lead-free stainless steel.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial; line-height: 26px;\"\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top: 20px; margin-bottom: 10px; line-height: 26px; color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP67 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eThe valves have an ingress - protection rating of IP67. The 6 in IP67 represents complete dust - tightness. The 7 in IP67 indicates protection against water immersion up to 1 meter for 30 minutes. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/IP67-SS304.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/Manual%20for%20Tonhe.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n    \u003cscript\u003e\n        const isMobile = window.matchMedia(\"only screen and (max-width: 600px)\").matches;\n        const desktopContent = document.querySelector('.desktop-only');\n        const mobileContent = document.querySelector('.mobile-only');\n\n        if (isMobile) {\n            console.log('The user is accessing from a mobile phone or tablet device.');\n            desktopContent.style.display = 'none';\n            mobileContent.style.display = 'block';\n        } else {\n            console.log('The user is accessing from a desktop device.');            \n            desktopContent.style.display = 'block';\n            mobileContent.style.display = 'none';\n        }\n    \u003c\/script\u003e\n\u003c\/body\u003e","brand":"U.S. Solid","offers":[{"title":"NPT","offer_id":47613956129023,"sku":"JFMSV50004","price":84.14,"currency_code":"USD","in_stock":true},{"title":"G","offer_id":47613956161791,"sku":"JFMSV50004-G","price":84.14,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/61bO1hFs5qL._AC_SL1500.jpg?v=1735024565"},{"product_id":"motorized-ball-valve-ip67-34-stainless-steel-waterproof-full-port-110-230v-ac-2-wire-auto-return-normally-open","title":"Motorized Ball Valve - IP67 3\/4\" Stainless Steel, Waterproof, Full Port, 110-230V AC, 2 Wire Auto Return, Normally Open","description":"\u003cbody\u003e\n\u003cstyle\u003e\n        @media only screen and (max-width: 600px) {\n        }\n    \u003c\/style\u003e\n\u003cdiv class=\"desktop-only\"\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top: 0px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; line-height: 26px; color: black; font-family: Arial; margin: 10px 0px 0px 0px;\"\u003eMotorized ball valves are a vital piece of equipment in numerous applications. This model opens and closes in 3-5 seconds, and remains in its new position while expending almost no energy. This is a key difference between motorized ball valves and many solenoid valves. Most solenoid valves are energized continuously when in a new position, while motorized ball valves expend energy only when changing from open to close, or vice versa.\u003cbr\u003eThe 2-wire auto-return model is perfect for situations where the valve needs to remain open in the event of power loss. The valve can be energized to close and, once fully closed, consumes negligible energy. To open the valve, simply shut off power. This valve is convenient because it can be operated with a simple on\/off switch: when powered on, it remains closed; when turned off—or if power is lost for any reason—the valve automatically opens.\u003c\/p\u003e\n\u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/features-JFMSV3.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n\u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #ffffff;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 0px; font-size: 16px; border: 0; background-color: #ffffff;\"\u003e\n\u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 3\/4\" style=\"width: 100%; height: 100%;\"\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 0px; font-size: 16px; border: 0; background-color: #ffffff;\"\u003e\n\u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 2\" style=\"width: 100%; height: 100%;\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n\u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #ffffff;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003eUSS-MSV50005\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003eU.S. Solid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003e3\/4\"\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003e2 Wire Auto Return\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003eSS304\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003eIP67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003e3 - 5 Seconds\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003e110- 230V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003e5 W\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003e2 N m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003e1.0 Mpa\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003e2°C to 90°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003e70,000 Cycles\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003eFull\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003eNPT\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003eNormally Open\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003e-15°C to 55°C\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003ePTFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial; line-height: 26px;\"\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eThe motor's housing is rated at IP67 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eYES. The motorized ball valve is made of lead-free stainless steel.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial; line-height: 26px;\"\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top: 20px; margin-bottom: 10px; line-height: 26px; color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP67 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eThe valves have an ingress - protection rating of IP67. The 6 in IP67 represents complete dust - tightness. The 7 in IP67 indicates protection against water immersion up to 1 meter for 30 minutes. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/IP67-SS304.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/Manual%20for%20Tonhe.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mobile-only\"\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top: 0px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; line-height: 26px; color: black; font-family: Arial; margin: 0px;\"\u003eMotorized ball valves are a vital piece of equipment in numerous applications. This model opens and closes in 3-5 seconds, and remains in its new position while expending almost no energy. This is a key difference between motorized ball valves and many solenoid valves. Most solenoid valves are energized continuously when in a new position, while motorized ball valves expend energy only when changing from open to close, or vice versa.\u003cbr\u003eThe 2-wire auto-return model is perfect for situations where the valve needs to remain open in the event of power loss. The valve can be energized to close and, once fully closed, consumes negligible energy. To open the valve, simply shut off power. This valve is convenient because it can be operated with a simple on\/off switch: when powered on, it remains closed; when turned off—or if power is lost for any reason—the valve automatically opens.\u003c\/p\u003e\n\u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/features-JFMSV3.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-bottom: 10px; margin-top: 20px; color: black;\"\u003e\u003cstrong\u003eAPPLICATION\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n\u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 3\/4\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n\u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 2\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 16px; text-align: left; margin-bottom: 10px; margin-top: 20px; color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n\u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #ffffff;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003eUSS-MSV50005\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003eU.S. Solid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003e3\/4\"\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003e2 Wire Auto Return\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003eSS304\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003eIP67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003e3 - 5 Seconds\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003e110- 230V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003e5 W\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003e2 N m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003e1.0 Mpa\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003e2°C to 90°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003e70,000 Cycles\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003eFull\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003eNPT\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003eNormally Open\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003e-15°C to 55°C\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003ePTFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial; line-height: 26px;\"\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eThe motor's housing is rated at IP67 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eYES. The motorized ball valve is made of lead-free stainless steel.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial; line-height: 26px;\"\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top: 20px; margin-bottom: 10px; line-height: 26px; color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP67 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eThe valves have an ingress - protection rating of IP67. The 6 in IP67 represents complete dust - tightness. The 7 in IP67 indicates protection against water immersion up to 1 meter for 30 minutes. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/IP67-SS304.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/Manual%20for%20Tonhe.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n    \u003cscript\u003e\n        const isMobile = window.matchMedia(\"only screen and (max-width: 600px)\").matches;\n        const desktopContent = document.querySelector('.desktop-only');\n        const mobileContent = document.querySelector('.mobile-only');\n\n        if (isMobile) {\n            console.log('The user is accessing from a mobile phone or tablet device.');\n            desktopContent.style.display = 'none';\n            mobileContent.style.display = 'block';\n        } else {\n            console.log('The user is accessing from a desktop device.');            \n            desktopContent.style.display = 'block';\n            mobileContent.style.display = 'none';\n        }\n    \u003c\/script\u003e\n\u003c\/body\u003e","brand":"U.S. Solid","offers":[{"title":"NPT","offer_id":47613961044223,"sku":"JFMSV50005","price":89.99,"currency_code":"USD","in_stock":true},{"title":"G","offer_id":47613961076991,"sku":"JFMSV50005-G","price":90.89,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/61KmoeAuilL._AC_SL1500.jpg?v=1735025792"},{"product_id":"motorized-ball-valve-ip67-1-stainless-steel-waterproof-full-port-110-230v-ac-2-wire-auto-return-normally-open","title":"Motorized Ball Valve - IP67 1\" Stainless Steel, Waterproof, Full Port, 110-230V AC, 2 Wire Auto Return, Normally Open","description":"\u003cbody\u003e\n\u003cstyle\u003e\n        @media only screen and (max-width: 600px) {\n        }\n    \u003c\/style\u003e\n\u003cdiv class=\"desktop-only\"\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top: 0px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; line-height: 26px; color: black; font-family: Arial; margin: 10px 0px 0px 0px;\"\u003eMotorized ball valves are a vital piece of equipment in numerous applications. This model opens and closes in 3-5 seconds, and remains in its new position while expending almost no energy. This is a key difference between motorized ball valves and many solenoid valves. Most solenoid valves are energized continuously when in a new position, while motorized ball valves expend energy only when changing from open to close, or vice versa.\u003cbr\u003eThe 2-wire auto-return model is perfect for situations where the valve needs to remain open in the event of power loss. The valve can be energized to close and, once fully closed, consumes negligible energy. To open the valve, simply shut off power. This valve is convenient because it can be operated with a simple on\/off switch: when powered on, it remains closed; when turned off—or if power is lost for any reason—the valve automatically opens.\u003c\/p\u003e\n\u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/features-JFMSV3.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n\u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #ffffff;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 0px; font-size: 16px; border: 0; background-color: #ffffff;\"\u003e\n\u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 1\" style=\"width: 100%; height: 100%;\"\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 0px; font-size: 16px; border: 0; background-color: #ffffff;\"\u003e\n\u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 2\" style=\"width: 100%; height: 100%;\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n\u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #ffffff;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003eUSS-MSV50006\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003eU.S. Solid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003e1\"\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003e2 Wire Auto Return\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003eSS304\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003eIP67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003e3 - 5 Seconds\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003e110- 230V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003e5 W\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003e2 N m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003e1.0 Mpa\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003e2°C to 90°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003e70,000 Cycles\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003eFull\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003eNPT\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003eNormally Open\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003e-15°C to 55°C\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003ePTFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial; line-height: 26px;\"\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eThe motor's housing is rated at IP67 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eYES. The motorized ball valve is made of lead-free stainless steel.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial; line-height: 26px;\"\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top: 20px; margin-bottom: 10px; line-height: 26px; color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP67 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eThe valves have an ingress - protection rating of IP67. The 6 in IP67 represents complete dust - tightness. The 7 in IP67 indicates protection against water immersion up to 1 meter for 30 minutes. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/IP67-SS304.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/Manual%20for%20Tonhe.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mobile-only\"\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top: 0px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; line-height: 26px; color: black; font-family: Arial; margin: 0px;\"\u003eMotorized ball valves are a vital piece of equipment in numerous applications. This model opens and closes in 3-5 seconds, and remains in its new position while expending almost no energy. This is a key difference between motorized ball valves and many solenoid valves. Most solenoid valves are energized continuously when in a new position, while motorized ball valves expend energy only when changing from open to close, or vice versa.\u003cbr\u003eThe 2-wire auto-return model is perfect for situations where the valve needs to remain open in the event of power loss. The valve can be energized to close and, once fully closed, consumes negligible energy. To open the valve, simply shut off power. This valve is convenient because it can be operated with a simple on\/off switch: when powered on, it remains closed; when turned off—or if power is lost for any reason—the valve automatically opens.\u003c\/p\u003e\n\u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/features-JFMSV3.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-bottom: 10px; margin-top: 20px; color: black;\"\u003e\u003cstrong\u003eAPPLICATION\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n\u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 1\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n\u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 2\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 16px; text-align: left; margin-bottom: 10px; margin-top: 20px; color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n\u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #ffffff;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003eUSS-MSV50006\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003eU.S. Solid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003e1\"\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003e2 Wire Auto Return\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003eSS304\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003eIP67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003e3 - 5 Seconds\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003e110- 230V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003e5 W\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003e2 N m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003e1.0 Mpa\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003e2°C to 90°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003e70,000 Cycles\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003eFull\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003eNPT\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003eNormally Open\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003e-15°C to 55°C\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003ePTFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial; line-height: 26px;\"\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eThe motor's housing is rated at IP67 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eYES. The motorized ball valve is made of lead-free stainless steel.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial; line-height: 26px;\"\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top: 20px; margin-bottom: 10px; line-height: 26px; color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP67 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eThe valves have an ingress - protection rating of IP67. The 6 in IP67 represents complete dust - tightness. The 7 in IP67 indicates protection against water immersion up to 1 meter for 30 minutes. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/IP67-SS304.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/Manual%20for%20Tonhe.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n    \u003cscript\u003e\n        const isMobile = window.matchMedia(\"only screen and (max-width: 600px)\").matches;\n        const desktopContent = document.querySelector('.desktop-only');\n        const mobileContent = document.querySelector('.mobile-only');\n\n        if (isMobile) {\n            console.log('The user is accessing from a mobile phone or tablet device.');\n            desktopContent.style.display = 'none';\n            mobileContent.style.display = 'block';\n        } else {\n            console.log('The user is accessing from a desktop device.');            \n            desktopContent.style.display = 'block';\n            mobileContent.style.display = 'none';\n        }\n    \u003c\/script\u003e\n\u003c\/body\u003e","brand":"U.S. Solid","offers":[{"title":"NPT","offer_id":47613963862271,"sku":"JFMSV50006","price":94.75,"currency_code":"USD","in_stock":true},{"title":"G","offer_id":47613963895039,"sku":"JFMSV50006-G","price":94.75,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/61bO1hFs5qL._AC_SL1500_a604d395-3060-4c20-b4e5-f159b6f6d8a2.jpg?v=1735025723"},{"product_id":"motorized-ball-valve-ip67-12-brass-waterproof-full-port-110-230v-ac-2-wire-auto-return-normally-open","title":"Motorized Ball Valve - IP67 1\/2\" Brass, Waterproof, Full Port, 110-230V AC, 2 Wire Auto Return, Normally Open","description":"\u003cstyle\u003e\n        @media only screen and (max-width: 600px) {\n        }\n    \u003c\/style\u003e\n\u003cdiv class=\"desktop-only\"\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top: 0px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; line-height: 26px; color: black; font-family: Arial; margin: 10px 0px 0px 0px;\"\u003eMotorized ball valves are a vital piece of equipment in numerous applications. This model opens and closes in 3-5 seconds, and remains in its new position while expending almost no energy. This is a key difference between motorized ball valves and many solenoid valves. Most solenoid valves are energized continuously when in a new position, while motorized ball valves expend energy only when changing from open to close, or vice versa.\u003cbrthe auto-return model is perfect for situations where the valve needs to remain open in event of power loss. can be energized close and once fully closed consumes negligible energy. simply shut off power. this convenient because it operated with a simple on switch: when powered remains turned if lost any reason automatically opens.\u003e\n\u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/features-JFMSV3.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n\u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #ffffff;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 0px; font-size: 16px; border: 0; background-color: #ffffff;\"\u003e\n\u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 1\" style=\"width: 100%; height: 100%;\"\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 0px; font-size: 16px; border: 0; background-color: #ffffff;\"\u003e\n\u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 2\" style=\"width: 100%; height: 100%;\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n\u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #ffffff;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003eUSS-MSV50010\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003eU.S. Solid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003e1\/2\"\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003e2 Wire Auto Return\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003eBrass\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003eIP67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003e3 - 5 Seconds\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003e110- 230V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003e5 W\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003e2 N m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003e1.0 Mpa\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003e2°C to 90°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003e70,000 Cycles\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003eFull\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003eNPT\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003eNormally Open\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003e-15°C to 55°C\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003ePTFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial; line-height: 26px;\"\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eThe motor's housing is rated at IP67 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eNO. This motorized ball valve is made of brass, which contains lead, should not be used for drinking water.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial; line-height: 26px;\"\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top: 20px; margin-bottom: 10px; line-height: 26px; color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP67 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eThe valves have an ingress - protection rating of IP67. The 6 in IP67 represents complete dust - tightness. The 7 in IP67 indicates protection against water immersion up to 1 meter for 30 minutes. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/IP67.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/Manual%20for%20Tonhe.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/brthe\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mobile-only\"\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top: 0px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; line-height: 26px; color: black; font-family: Arial; margin: 0px;\"\u003eMotorized ball valves are a vital piece of equipment in numerous applications. This model opens and closes in 3-5 seconds, and remains in its new position while expending almost no energy. This is a key difference between motorized ball valves and many solenoid valves. Most solenoid valves are energized continuously when in a new position, while motorized ball valves expend energy only when changing from open to close, or vice versa.\u003cbr\u003eThe 2-wire auto-return model is perfect for situations where the valve needs to remain open in the event of power loss. The valve can be energized to close and, once fully closed, consumes negligible energy. To open the valve, simply shut off power. This valve is convenient because it can be operated with a simple on\/off switch: when powered on, it remains closed; when turned off—or if power is lost for any reason—the valve automatically opens.\u003c\/p\u003e\n\u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/features-JFMSV3.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-bottom: 10px; margin-top: 20px; color: black;\"\u003e\u003cstrong\u003eAPPLICATION\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n\u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 1\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n\u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 2\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 16px; text-align: left; margin-bottom: 10px; margin-top: 20px; color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n\u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #ffffff;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003eUSS-MSV50010\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003eU.S. Solid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003e1\/2\"\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003e2 Wire Auto Return\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003eBrass\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003ePTFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003e3 - 5 Seconds\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003e110- 230V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003e5 W\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003e2 N m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003e1.0 Mpa\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003e2°C to 90°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003e70,000 Cycles\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003eFull\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003eNPT\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003eNormally Open\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003e-15°C to 55°C\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003eIP67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial; line-height: 26px;\"\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eThe motor's housing is rated at IP67 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eNO. This motorized ball valve is made of brass, which contains lead, should not be used for drinking water.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial; line-height: 26px;\"\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top: 20px; margin-bottom: 10px; line-height: 26px; color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP67 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eThe valves have an ingress - protection rating of IP67. The 6 in IP67 represents complete dust - tightness. The 7 in IP67 indicates protection against water immersion up to 1 meter for 30 minutes. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/IP67.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/Manual%20for%20Tonhe.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"U.S. Solid","offers":[{"title":"NPT","offer_id":47614014062847,"sku":"JFMSV50010","price":76.04,"currency_code":"USD","in_stock":true},{"title":"G","offer_id":47614014095615,"sku":"JFMSV50010-G","price":76.04,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/61KmoeAuilL._AC_SL1500_bb64771d-07b5-4a45-b6e8-4170cd6be606.jpg?v=1735027805"},{"product_id":"motorized-ball-valve-ip67-34-brass-waterproof-full-port-110-230v-ac-2-wire-auto-return-normally-open","title":"Motorized Ball Valve - IP67 3\/4\" Brass, Waterproof, Full Port, 110-230V AC, 2 Wire Auto Return, Normally Open","description":"\u003cstyle\u003e\n        @media only screen and (max-width: 600px) {\n        }\n    \u003c\/style\u003e\n\u003cdiv class=\"desktop-only\"\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top: 0px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; line-height: 26px; color: black; font-family: Arial; margin: 10px 0px 0px 0px;\"\u003eMotorized ball valves are a vital piece of equipment in numerous applications. This model opens and closes in 3-5 seconds, and remains in its new position while expending almost no energy. This is a key difference between motorized ball valves and many solenoid valves. Most solenoid valves are energized continuously when in a new position, while motorized ball valves expend energy only when changing from open to close, or vice versa.\u003cbr\u003eThe 2-wire auto-return model is perfect for situations where the valve needs to remain open in the event of power loss. The valve can be energized to close and, once fully closed, consumes negligible energy. To open the valve, simply shut off power. This valve is convenient because it can be operated with a simple on\/off switch: when powered on, it remains closed; when turned off—or if power is lost for any reason—the valve automatically opens.\u003c\/p\u003e\n\u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/features-JFMSV3.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n\u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #ffffff;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 0px; font-size: 16px; border: 0; background-color: #ffffff;\"\u003e\n\u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 1\" style=\"width: 100%; height: 100%;\"\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 0px; font-size: 16px; border: 0; background-color: #ffffff;\"\u003e\n\u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 2\" style=\"width: 100%; height: 100%;\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n\u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #ffffff;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003eUSS-MSV50011\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003eU.S. Solid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003e3\/4\"\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003e2 Wire Auto Return\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003eBrass\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003eIP67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003e3 - 5 Seconds\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003e110- 230V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003e5 W\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003e2 N m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003e1.0 Mpa\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003e2°C to 90°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003e70,000 Cycles\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003eFull\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003eNPT\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003eNormally Open\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003e-15°C to 55°C\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003ePTFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial; line-height: 26px;\"\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eThe motor's housing is rated at IP67 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eNO. This motorized ball valve is made of brass, which contains lead, should not be used for drinking water.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial; line-height: 26px;\"\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top: 20px; margin-bottom: 10px; line-height: 26px; color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP67 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eThe valves have an ingress - protection rating of IP67. The 6 in IP67 represents complete dust - tightness. The 7 in IP67 indicates protection against water immersion up to 1 meter for 30 minutes. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/IP67.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/Manual%20for%20Tonhe.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mobile-only\"\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top: 0px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; line-height: 26px; color: black; font-family: Arial; margin: 0px;\"\u003eMotorized ball valves are a vital piece of equipment in numerous applications. This model opens and closes in 3-5 seconds, and remains in its new position while expending almost no energy. This is a key difference between motorized ball valves and many solenoid valves. Most solenoid valves are energized continuously when in a new position, while motorized ball valves expend energy only when changing from open to close, or vice versa.\u003cbr\u003eThe 2-wire auto-return model is perfect for situations where the valve needs to remain open in the event of power loss. The valve can be energized to close and, once fully closed, consumes negligible energy. To open the valve, simply shut off power. This valve is convenient because it can be operated with a simple on\/off switch: when powered on, it remains closed; when turned off—or if power is lost for any reason—the valve automatically opens.\u003c\/p\u003e\n\u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/features-JFMSV3.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-bottom: 10px; margin-top: 20px; color: black;\"\u003e\u003cstrong\u003eAPPLICATION\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n\u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 1\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n\u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 2\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 16px; text-align: left; margin-bottom: 10px; margin-top: 20px; color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n\u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #ffffff;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003eUSS-MSV50011\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003eU.S. Solid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003e3\/4\"\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003e2 Wire Auto Return\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003eBrass\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003eIP67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003e3 - 5 Seconds\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003e110- 230V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003e5 W\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003e2 N m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003e1.0 Mpa\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003e2°C to 90°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003e70,000 Cycles\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003eFull\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003eNPT\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003eNormally Open\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003e-15°C to 55°C\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003ePTFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial; line-height: 26px;\"\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eThe motor's housing is rated at IP67 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eNO. This motorized ball valve is made of brass, which contains lead, should not be used for drinking water.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial; line-height: 26px;\"\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top: 20px; margin-bottom: 10px; line-height: 26px; color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP67 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eThe valves have an ingress - protection rating of IP67. The 6 in IP67 represents complete dust - tightness. The 7 in IP67 indicates protection against water immersion up to 1 meter for 30 minutes. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/IP67.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/Manual%20for%20Tonhe.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"U.S. Solid","offers":[{"title":"NPT","offer_id":47614016258303,"sku":"JFMSV50011","price":83.89,"currency_code":"USD","in_stock":true},{"title":"G","offer_id":47614016291071,"sku":"JFMSV50011-G","price":83.89,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/61KmoeAuilL._AC_SL1500_b4bec68b-2fb8-4cef-b371-0af8bcb43c21.jpg?v=1735027939"},{"product_id":"motorized-ball-valve-ip67-1-brass-waterproof-full-port-110-230v-ac-2-wire-auto-return-normally-open","title":"Motorized Ball Valve - IP67 1\" Brass, Waterproof, Full Port, 110-230V AC, 2 Wire Auto Return, Normally Open","description":"\u003cstyle\u003e\n        @media only screen and (max-width: 600px) {\n        }\n    \u003c\/style\u003e\n\u003cdiv class=\"desktop-only\"\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top: 0px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; line-height: 26px; color: black; font-family: Arial; margin: 10px 0px 0px 0px;\"\u003eMotorized ball valves are a vital piece of equipment in numerous applications. This model opens and closes in 3-5 seconds, and remains in its new position while expending almost no energy. This is a key difference between motorized ball valves and many solenoid valves. Most solenoid valves are energized continuously when in a new position, while motorized ball valves expend energy only when changing from open to close, or vice versa.\u003cbr\u003eThe 2-wire auto-return model is perfect for situations where the valve needs to remain open in the event of power loss. The valve can be energized to close and, once fully closed, consumes negligible energy. To open the valve, simply shut off power. This valve is convenient because it can be operated with a simple on\/off switch: when powered on, it remains closed; when turned off—or if power is lost for any reason—the valve automatically opens.\u003c\/p\u003e\n\u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/features-JFMSV3.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n\u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #ffffff;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 0px; font-size: 16px; border: 0; background-color: #ffffff;\"\u003e\n\u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 1\" style=\"width: 100%; height: 100%;\"\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 0px; font-size: 16px; border: 0; background-color: #ffffff;\"\u003e\n\u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 2\" style=\"width: 100%; height: 100%;\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n\u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #ffffff;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003eUSS-MSV50012\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003eU.S. Solid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003e1\"\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003e2 Wire Auto Return\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003eBrass\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003eIP67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003e3 - 5 Seconds\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003e110- 230V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003e5 W\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003e2 N m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003e1.0 Mpa\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003e2°C to 90°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003e70,000 Cycles\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003eFull\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003eNPT\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003eNormally Open\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003e-15°C to 55°C\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003ePTFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial; line-height: 26px;\"\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eThe motor's housing is rated at IP67 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eNO. This motorized ball valve is made of brass, which contains lead, should not be used for drinking water.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial; line-height: 26px;\"\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top: 20px; margin-bottom: 10px; line-height: 26px; color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP67 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eThe valves have an ingress - protection rating of IP67. The 6 in IP67 represents complete dust - tightness. The 7 in IP67 indicates protection against water immersion up to 1 meter for 30 minutes. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/IP67.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/Manual%20for%20Tonhe.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mobile-only\"\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top: 0px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; line-height: 26px; color: black; font-family: Arial; margin: 0px;\"\u003eMotorized ball valves are a vital piece of equipment in numerous applications. This model opens and closes in 3-5 seconds, and remains in its new position while expending almost no energy. This is a key difference between motorized ball valves and many solenoid valves. Most solenoid valves are energized continuously when in a new position, while motorized ball valves expend energy only when changing from open to close, or vice versa.\u003cbr\u003eThe 2-wire auto-return model is perfect for situations where the valve needs to remain open in the event of power loss. The valve can be energized to close and, once fully closed, consumes negligible energy. To open the valve, simply shut off power. This valve is convenient because it can be operated with a simple on\/off switch: when powered on, it remains closed; when turned off—or if power is lost for any reason—the valve automatically opens.\u003c\/p\u003e\n\u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/features-JFMSV3.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-bottom: 10px; margin-top: 20px; color: black;\"\u003e\u003cstrong\u003eAPPLICATION\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n\u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 1\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n\u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 2\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 16px; text-align: left; margin-bottom: 10px; margin-top: 20px; color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n\u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #ffffff;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003eUSS-MSV50012\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003eU.S. Solid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003e1\"\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003e2 Wire Auto Return\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003eBrass\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003eIP67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003e3 - 5 Seconds\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003e110- 230V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003e5 W\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003e2 N m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003e1.0 Mpa\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003e2°C to 90°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003e70,000 Cycles\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003eFull\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003eNPT\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003eNormally Open\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003e-15°C to 55°C\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003ePTFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial; line-height: 26px;\"\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eThe motor's housing is rated at IP67 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eNO. This motorized ball valve is made of brass, which contains lead, should not be used for drinking water.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial; line-height: 26px;\"\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top: 20px; margin-bottom: 10px; line-height: 26px; color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP67 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eThe valves have an ingress - protection rating of IP67. The 6 in IP67 represents complete dust - tightness. The 7 in IP67 indicates protection against water immersion up to 1 meter for 30 minutes. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/IP67.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/Manual%20for%20Tonhe.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"U.S. Solid","offers":[{"title":"NPT","offer_id":47614016553215,"sku":"JFMSV50012","price":88.24,"currency_code":"USD","in_stock":true},{"title":"G","offer_id":47614016585983,"sku":"JFMSV50012-G","price":88.24,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/61KmoeAuilL._AC_SL1500_32eb4288-9069-4bcc-869a-1a87d54114c4.jpg?v=1735028315"},{"product_id":"1-2-brass-motorised-ball-valve-ac-110-220-v-3-way-t-type-2-wire-auto-return-16-bar-stardard-port","title":"1\/2\" Brass Motorised Ball Valve, AC 110-230V, 3 Way T-type , 2 Wire, 16 bar, Stardard Port","description":"\u003cbody\u003e\n\u003cstyle\u003e\n.jfmsv-detail,.jfmsv-detail *{box-sizing:border-box}\n.jfmsv-detail{width:100%;max-width:100%;margin:0;overflow-x:hidden;color:#17202b;font-family:Arial,Helvetica,sans-serif;line-height:1.65}\n.jfmsv-heading{margin:28px 0 14px;padding-left:12px;border-left:4px solid #b98538;color:#17202b;font-size:22px;line-height:1.3;font-weight:700;letter-spacing:.035em}\n.jfmsv-detail p,.jfmsv-detail li{font-size:16px;line-height:1.7}\n.jfmsv-cover{display:block;width:100%;height:auto;max-width:100%;border:0;background:#fff}.jfmsv-feature-image-slot{display:block;width:100%;height:auto;max-width:100%;background:#fff}.jfmsv-working-grid{display:grid;grid-template-columns:repeat(2,minmax(0,1fr));gap:16px;margin:0 0 18px}.jfmsv-working-grid img{display:block;width:100%;height:auto}\n.jfmsv-specs{width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;margin:12px 0 24px}.jfmsv-specs th,.jfmsv-specs td{overflow-wrap:anywhere}\n.jfmsv-faq{margin:0 0 18px}\n.jfmsv-faq strong{display:block;margin-bottom:4px}\n@media(max-width:700px){.jfmsv-working-grid{grid-template-columns:1fr}}\n@media(max-width:600px){.jfmsv-heading{font-size:21px;margin:24px 0 12px}.jfmsv-detail p,.jfmsv-detail li{font-size:15px}.jfmsv-specs th,.jfmsv-specs td{padding:8px!important;font-size:14px}}\n\u003c\/style\u003e\n\u003cdiv class=\"jfmsv-detail\"\u003e\n\u003cimg class=\"jfmsv-cover\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage-JFMSV10096.jpg\" alt=\"JFMSV series motorized ball valve\" loading=\"lazy\"\u003e\n\u003ch2 class=\"jfmsv-heading\"\u003eINTRODUCTION\u003c\/h2\u003e\n\u003cp\u003eU.S. Solid 1\/2-inch brass 3-way T-port motorized ball valve for switching or diverting flow in compatible non-potable fluid circuits. The 2-wire auto-return control opens when the switch is closed and returns the valve toward closed when the switch is opened. Power is automatically cut at the end positions. The brass body uses a PTFE sealing ring and is rated for a maximum operating pressure of 16 bar. Confirm the thread, pressure, temperature, and electrical rating for your exact valve before installation.\u003c\/p\u003e\n\u003ch2 class=\"jfmsv-heading\"\u003eHOW IT WORKS\u003c\/h2\u003e\n\u003cdiv class=\"jfmsv-working-grid\"\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/JFMSV10096.gif\" alt=\"How the motorized ball valve operates\" loading=\"lazy\"\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/JFMSV10096-2.gif\" alt=\"Motorized ball valve operation diagram\" loading=\"lazy\"\u003e\n\u003c\/div\u003e\n\u003ch2 class=\"jfmsv-heading\"\u003eFEATURES\u003c\/h2\u003e\n\u003cimg class=\"jfmsv-feature-image-slot\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/features-JFMSV10096.jpg\" alt=\"Features of the JFMSV series motorized ball valve\" loading=\"lazy\"\u003e\n\u003ch2 class=\"jfmsv-heading\"\u003eAPPLICATIONS\u003c\/h2\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" alt=\"Typical motorized ball valve applications\" style=\"display:block;width:100%;height:auto;border:0;margin:0 0 12px;\"\u003e\n\u003cp\u003eUse in compatible non-potable water circulation, hydronic heating and cooling loops, and systems using water mixed with up to 50% ethylene glycol. Select the T-port orientation and control method to match the system flow path.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNot for drinking-water service.\u003c\/strong\u003e Brass valves may contain lead; see the WARNING section.\u003c\/p\u003e\n\u003ch2 class=\"jfmsv-heading\"\u003eSPECIFICATIONS\u003c\/h2\u003e\n\u003cdiv style=\"width:100%;max-width:100%;\"\u003e\u003ctable class=\"jfmsv-specs\"\u003e\n\u003ctr\u003e\n\u003cth style=\"width:17%;text-align:left;background:#f5f7f9;font-weight:700;padding:10px 12px;border:1px solid #d9e0e6;\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003eUSS-MSV10096 (NPT), USS-MSV10096-G (G)\u003c\/td\u003e\n\u003cth style=\"width:17%;text-align:left;background:#f5f7f9;font-weight:700;padding:10px 12px;border:1px solid #d9e0e6;\"\u003eNominal size\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003e1\/2 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:17%;text-align:left;background:#f5f7f9;font-weight:700;padding:10px 12px;border:1px solid #d9e0e6;\"\u003eValve configuration\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003e3-way T-port\u003c\/td\u003e\n\u003cth style=\"width:17%;text-align:left;background:#f5f7f9;font-weight:700;padding:10px 12px;border:1px solid #d9e0e6;\"\u003ePort type\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003eStandard port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:17%;text-align:left;background:#f5f7f9;font-weight:700;padding:10px 12px;border:1px solid #d9e0e6;\"\u003eControl type\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003e2 Wire\u003c\/td\u003e\n\u003cth style=\"width:17%;text-align:left;background:#f5f7f9;font-weight:700;padding:10px 12px;border:1px solid #d9e0e6;\"\u003eVoltage\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003eAC 110-230V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:17%;text-align:left;background:#f5f7f9;font-weight:700;padding:10px 12px;border:1px solid #d9e0e6;\"\u003eFlow aperture\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003e12 mm\u003c\/td\u003e\n\u003cth style=\"width:17%;text-align:left;background:#f5f7f9;font-weight:700;padding:10px 12px;border:1px solid #d9e0e6;\"\u003eValve body\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003eBrass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:17%;text-align:left;background:#f5f7f9;font-weight:700;padding:10px 12px;border:1px solid #d9e0e6;\"\u003eSeal material\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003ePTFE\u003c\/td\u003e\n\u003cth style=\"width:17%;text-align:left;background:#f5f7f9;font-weight:700;padding:10px 12px;border:1px solid #d9e0e6;\"\u003eMaximum operating pressure\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003e16 bar (232 psi)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:17%;text-align:left;background:#f5f7f9;font-weight:700;padding:10px 12px;border:1px solid #d9e0e6;\"\u003eMedia temperature\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003e0–90 °C (32–194 °F)\u003c\/td\u003e\n\u003cth style=\"width:17%;text-align:left;background:#f5f7f9;font-weight:700;padding:10px 12px;border:1px solid #d9e0e6;\"\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003e0–60 °C (32–140 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:17%;text-align:left;background:#f5f7f9;font-weight:700;padding:10px 12px;border:1px solid #d9e0e6;\"\u003eEnclosure rating\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003eIP54\u003c\/td\u003e\n\u003cth style=\"width:17%;text-align:left;background:#f5f7f9;font-weight:700;padding:10px 12px;border:1px solid #d9e0e6;\"\u003eOperating torque\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003e6 Nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:17%;text-align:left;background:#f5f7f9;font-weight:700;padding:10px 12px;border:1px solid #d9e0e6;\"\u003eTravel time\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003e6–15 s\u003c\/td\u003e\n\u003cth style=\"width:17%;text-align:left;background:#f5f7f9;font-weight:700;padding:10px 12px;border:1px solid #d9e0e6;\"\u003eRated power\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003e7.5 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:17%;text-align:left;background:#f5f7f9;font-weight:700;padding:10px 12px;border:1px solid #d9e0e6;\"\u003eCompatible media\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003eWater or up to 50% ethylene glycol solution\u003c\/td\u003e\n\u003cth style=\"width:17%;text-align:left;background:#f5f7f9;font-weight:700;padding:10px 12px;border:1px solid #d9e0e6;\"\u003eService life\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003eUp to 100,000 cycles (listed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch2 class=\"jfmsv-heading\"\u003eFAQ\u003c\/h2\u003e\n\u003cdiv class=\"jfmsv-faq\"\u003e\n\u003cstrong\u003eWhat does the T-port configuration do?\u003c\/strong\u003e\u003cp style=\"margin:0;\"\u003eThe ball's T-shaped passage routes flow between three ports. Confirm the port orientation and flow direction against your piping layout and the manual diagrams.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"jfmsv-faq\"\u003e\n\u003cstrong\u003eHow does this wiring type operate?\u003c\/strong\u003e\u003cp style=\"margin:0;\"\u003eWith the 2-wire auto-return model, closing the switch opens the valve; opening the switch closes it. Follow the wiring diagram in the manual.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"jfmsv-faq\"\u003e\n\u003cstrong\u003eCan I use it with ethylene glycol?\u003c\/strong\u003e\u003cp style=\"margin:0;\"\u003eThe supplied product data lists water and a solution containing up to 50% ethylene glycol. Confirm chemical compatibility with all system materials and stay within the rated pressure and temperature limits.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch2 class=\"jfmsv-heading\" style=\"border-left-color:#b13b35;\"\u003eWARNING\u003c\/h2\u003e\n\u003cul style=\"padding-left:22px;margin:0 0 18px;\"\u003e\n\u003cli\u003eBrass valves may contain lead. Do not use this valve for drinking-water service.\u003c\/li\u003e\n\u003cli\u003eDisconnect the power supply before wiring or servicing. Use the voltage listed in the specifications and verify the wiring before connecting the supply.\u003c\/li\u003e\n\u003cli\u003eThe manual instructs that the valve remain powered for at least 1 minute. Follow the wiring diagram and instructions before operation.\u003c\/li\u003e\n\u003cli\u003eDo not exceed 16 bar, 0–90 °C media temperature, or 0–60 °C ambient temperature. IP54 protects against dust ingress and splashing water; it is not an immersion rating.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"jfmsv-heading\"\u003eMANUAL DOWNLOAD\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/Manual-JFMSV10096.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eDownload the 3-Way Motorized Ball Valve Manual (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/body\u003e","brand":"U.S. Solid","offers":[{"title":"NPT","offer_id":49166884798719,"sku":"JFMSV10096","price":44.07,"currency_code":"USD","in_stock":true},{"title":"G","offer_id":49166884831487,"sku":"JFMSV10096-G","price":44.07,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/1_187f9dae-8238-44ea-9418-08138afee2cf.jpg?v=1792474517"},{"product_id":"3-4-brass-motorised-ball-valve-ac-110-220-v-3-way-t-type-2-wire-auto-return-16-bar-stardard-port","title":"3\/4\" Brass Motorised Ball Valve, AC 110-230V, 3 Way T-type , 2 Wire, 16 bar, Stardard Port","description":"\u003cbody\u003e\n\u003cstyle\u003e\n.jfmsv-detail,.jfmsv-detail *{box-sizing:border-box}\n.jfmsv-detail{width:100%;max-width:100%;margin:0;overflow-x:hidden;color:#17202b;font-family:Arial,Helvetica,sans-serif;line-height:1.65}\n.jfmsv-heading{margin:28px 0 14px;padding-left:12px;border-left:4px solid #b98538;color:#17202b;font-size:22px;line-height:1.3;font-weight:700;letter-spacing:.035em}\n.jfmsv-detail p,.jfmsv-detail li{font-size:16px;line-height:1.7}\n.jfmsv-cover{display:block;width:100%;height:auto;max-width:100%;border:0;background:#fff}.jfmsv-feature-image-slot{display:block;width:100%;height:auto;max-width:100%;background:#fff}.jfmsv-working-grid{display:grid;grid-template-columns:repeat(2,minmax(0,1fr));gap:16px;margin:0 0 18px}.jfmsv-working-grid img{display:block;width:100%;height:auto}\n.jfmsv-specs{width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;margin:12px 0 24px}.jfmsv-specs th,.jfmsv-specs td{overflow-wrap:anywhere}\n.jfmsv-faq{margin:0 0 18px}\n.jfmsv-faq strong{display:block;margin-bottom:4px}\n@media(max-width:700px){.jfmsv-working-grid{grid-template-columns:1fr}}\n@media(max-width:600px){.jfmsv-heading{font-size:21px;margin:24px 0 12px}.jfmsv-detail p,.jfmsv-detail li{font-size:15px}.jfmsv-specs th,.jfmsv-specs td{padding:8px!important;font-size:14px}}\n\u003c\/style\u003e\n\u003cdiv class=\"jfmsv-detail\"\u003e\n\u003cimg class=\"jfmsv-cover\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage-JFMSV10096.jpg\" alt=\"JFMSV series motorized ball valve\" loading=\"lazy\"\u003e\n\u003ch2 class=\"jfmsv-heading\"\u003eINTRODUCTION\u003c\/h2\u003e\n\u003cp\u003eU.S. Solid 3\/4-inch brass 3-way T-port motorized ball valve for switching or diverting flow in compatible non-potable fluid circuits. The 2-wire auto-return control opens when the switch is closed and returns the valve toward closed when the switch is opened. Power is automatically cut at the end positions. The brass body uses a PTFE sealing ring and is rated for a maximum operating pressure of 16 bar. Confirm the thread, pressure, temperature, and electrical rating for your exact valve before installation.\u003c\/p\u003e\n\u003ch2 class=\"jfmsv-heading\"\u003eHOW IT WORKS\u003c\/h2\u003e\n\u003cdiv class=\"jfmsv-working-grid\"\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/JFMSV10096.gif\" alt=\"How the motorized ball valve operates\" loading=\"lazy\"\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/JFMSV10096-2.gif\" alt=\"Motorized ball valve operation diagram\" loading=\"lazy\"\u003e\n\u003c\/div\u003e\n\u003ch2 class=\"jfmsv-heading\"\u003eFEATURES\u003c\/h2\u003e\n\u003cimg class=\"jfmsv-feature-image-slot\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/features-JFMSV10096.jpg\" alt=\"Features of the JFMSV series motorized ball valve\" loading=\"lazy\"\u003e\n\u003ch2 class=\"jfmsv-heading\"\u003eAPPLICATIONS\u003c\/h2\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" alt=\"Typical motorized ball valve applications\" style=\"display:block;width:100%;height:auto;border:0;margin:0 0 12px;\"\u003e\n\u003cp\u003eUse in compatible non-potable water circulation, hydronic heating and cooling loops, and systems using water mixed with up to 50% ethylene glycol. Select the T-port orientation and control method to match the system flow path.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNot for drinking-water service.\u003c\/strong\u003e Brass valves may contain lead; see the WARNING section.\u003c\/p\u003e\n\u003ch2 class=\"jfmsv-heading\"\u003eSPECIFICATIONS\u003c\/h2\u003e\n\u003cdiv style=\"width:100%;max-width:100%;\"\u003e\u003ctable class=\"jfmsv-specs\"\u003e\n\u003ctr\u003e\n\u003cth style=\"width:17%;text-align:left;background:#f5f7f9;font-weight:700;padding:10px 12px;border:1px solid #d9e0e6;\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003eUSS-MSV10097 (NPT), USS-MSV10097-G (G)\u003c\/td\u003e\n\u003cth style=\"width:17%;text-align:left;background:#f5f7f9;font-weight:700;padding:10px 12px;border:1px solid #d9e0e6;\"\u003eNominal size\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003e3\/4 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:17%;text-align:left;background:#f5f7f9;font-weight:700;padding:10px 12px;border:1px solid #d9e0e6;\"\u003eValve configuration\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003e3-way T-port\u003c\/td\u003e\n\u003cth style=\"width:17%;text-align:left;background:#f5f7f9;font-weight:700;padding:10px 12px;border:1px solid #d9e0e6;\"\u003ePort type\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003eStandard port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:17%;text-align:left;background:#f5f7f9;font-weight:700;padding:10px 12px;border:1px solid #d9e0e6;\"\u003eControl type\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003e2 Wire\u003c\/td\u003e\n\u003cth style=\"width:17%;text-align:left;background:#f5f7f9;font-weight:700;padding:10px 12px;border:1px solid #d9e0e6;\"\u003eVoltage\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003eAC 110-230V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:17%;text-align:left;background:#f5f7f9;font-weight:700;padding:10px 12px;border:1px solid #d9e0e6;\"\u003eFlow aperture\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003e17 mm\u003c\/td\u003e\n\u003cth style=\"width:17%;text-align:left;background:#f5f7f9;font-weight:700;padding:10px 12px;border:1px solid #d9e0e6;\"\u003eValve body\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003eBrass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:17%;text-align:left;background:#f5f7f9;font-weight:700;padding:10px 12px;border:1px solid #d9e0e6;\"\u003eSeal material\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003ePTFE\u003c\/td\u003e\n\u003cth style=\"width:17%;text-align:left;background:#f5f7f9;font-weight:700;padding:10px 12px;border:1px solid #d9e0e6;\"\u003eMaximum operating pressure\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003e16 bar (232 psi)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:17%;text-align:left;background:#f5f7f9;font-weight:700;padding:10px 12px;border:1px solid #d9e0e6;\"\u003eMedia temperature\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003e0–90 °C (32–194 °F)\u003c\/td\u003e\n\u003cth style=\"width:17%;text-align:left;background:#f5f7f9;font-weight:700;padding:10px 12px;border:1px solid #d9e0e6;\"\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003e0–60 °C (32–140 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:17%;text-align:left;background:#f5f7f9;font-weight:700;padding:10px 12px;border:1px solid #d9e0e6;\"\u003eEnclosure rating\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003eIP54\u003c\/td\u003e\n\u003cth style=\"width:17%;text-align:left;background:#f5f7f9;font-weight:700;padding:10px 12px;border:1px solid #d9e0e6;\"\u003eOperating torque\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003e6 Nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:17%;text-align:left;background:#f5f7f9;font-weight:700;padding:10px 12px;border:1px solid #d9e0e6;\"\u003eTravel time\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003e6–15 s\u003c\/td\u003e\n\u003cth style=\"width:17%;text-align:left;background:#f5f7f9;font-weight:700;padding:10px 12px;border:1px solid #d9e0e6;\"\u003eRated power\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003e7.5 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:17%;text-align:left;background:#f5f7f9;font-weight:700;padding:10px 12px;border:1px solid #d9e0e6;\"\u003eCompatible media\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003eWater or up to 50% ethylene glycol solution\u003c\/td\u003e\n\u003cth style=\"width:17%;text-align:left;background:#f5f7f9;font-weight:700;padding:10px 12px;border:1px solid #d9e0e6;\"\u003eService life\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003eUp to 100,000 cycles (listed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch2 class=\"jfmsv-heading\"\u003eFAQ\u003c\/h2\u003e\n\u003cdiv class=\"jfmsv-faq\"\u003e\n\u003cstrong\u003eWhat does the T-port configuration do?\u003c\/strong\u003e\u003cp style=\"margin:0;\"\u003eThe ball's T-shaped passage routes flow between three ports. Confirm the port orientation and flow direction against your piping layout and the manual diagrams.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"jfmsv-faq\"\u003e\n\u003cstrong\u003eHow does this wiring type operate?\u003c\/strong\u003e\u003cp style=\"margin:0;\"\u003eWith the 2-wire auto-return model, closing the switch opens the valve; opening the switch closes it. Follow the wiring diagram in the manual.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"jfmsv-faq\"\u003e\n\u003cstrong\u003eCan I use it with ethylene glycol?\u003c\/strong\u003e\u003cp style=\"margin:0;\"\u003eThe supplied product data lists water and a solution containing up to 50% ethylene glycol. Confirm chemical compatibility with all system materials and stay within the rated pressure and temperature limits.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch2 class=\"jfmsv-heading\" style=\"border-left-color:#b13b35;\"\u003eWARNING\u003c\/h2\u003e\n\u003cul style=\"padding-left:22px;margin:0 0 18px;\"\u003e\n\u003cli\u003eBrass valves may contain lead. Do not use this valve for drinking-water service.\u003c\/li\u003e\n\u003cli\u003eDisconnect the power supply before wiring or servicing. Use the voltage listed in the specifications and verify the wiring before connecting the supply.\u003c\/li\u003e\n\u003cli\u003eThe manual instructs that the valve remain powered for at least 1 minute. Follow the wiring diagram and instructions before operation.\u003c\/li\u003e\n\u003cli\u003eDo not exceed 16 bar, 0–90 °C media temperature, or 0–60 °C ambient temperature. IP54 protects against dust ingress and splashing water; it is not an immersion rating.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"jfmsv-heading\"\u003eMANUAL DOWNLOAD\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/Manual-JFMSV10096.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eDownload the 3-Way Motorized Ball Valve Manual (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/body\u003e","brand":"U.S. Solid","offers":[{"title":"NPT","offer_id":49166889386239,"sku":"JFMSV10097","price":48.71,"currency_code":"USD","in_stock":true},{"title":"G","offer_id":49166889419007,"sku":"JFMSV10097-G","price":48.71,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/1_32a5947d-03b9-4d0b-a84c-e0694c1f67b9.jpg?v=1792474601"},{"product_id":"1-brass-motorised-ball-valve-ac-110-220-v-3-way-t-type-3-wire-dual-control-16-bar-stardard-port","title":"1\" Brass Motorised Ball Valve, AC 110-230V, 3 Way T-type , 2 Wire, 16 bar, Stardard Port","description":"\u003cbody\u003e\n\u003cstyle\u003e\n.jfmsv-detail,.jfmsv-detail *{box-sizing:border-box}\n.jfmsv-detail{width:100%;max-width:100%;margin:0;overflow-x:hidden;color:#17202b;font-family:Arial,Helvetica,sans-serif;line-height:1.65}\n.jfmsv-heading{margin:28px 0 14px;padding-left:12px;border-left:4px solid #b98538;color:#17202b;font-size:22px;line-height:1.3;font-weight:700;letter-spacing:.035em}\n.jfmsv-detail p,.jfmsv-detail li{font-size:16px;line-height:1.7}\n.jfmsv-cover{display:block;width:100%;height:auto;max-width:100%;border:0;background:#fff}.jfmsv-feature-image-slot{display:block;width:100%;height:auto;max-width:100%;background:#fff}.jfmsv-working-grid{display:grid;grid-template-columns:repeat(2,minmax(0,1fr));gap:16px;margin:0 0 18px}.jfmsv-working-grid img{display:block;width:100%;height:auto}\n.jfmsv-specs{width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;margin:12px 0 24px}.jfmsv-specs th,.jfmsv-specs td{overflow-wrap:anywhere}\n.jfmsv-faq{margin:0 0 18px}\n.jfmsv-faq strong{display:block;margin-bottom:4px}\n@media(max-width:700px){.jfmsv-working-grid{grid-template-columns:1fr}}\n@media(max-width:600px){.jfmsv-heading{font-size:21px;margin:24px 0 12px}.jfmsv-detail p,.jfmsv-detail li{font-size:15px}.jfmsv-specs th,.jfmsv-specs td{padding:8px!important;font-size:14px}}\n\u003c\/style\u003e\n\u003cdiv class=\"jfmsv-detail\"\u003e\n\u003cimg class=\"jfmsv-cover\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage-JFMSV10096.jpg\" alt=\"JFMSV series motorized ball valve\" loading=\"lazy\"\u003e\n\u003ch2 class=\"jfmsv-heading\"\u003eINTRODUCTION\u003c\/h2\u003e\n\u003cp\u003eU.S. Solid 1-inch brass 3-way T-port motorized ball valve for switching or diverting flow in compatible non-potable fluid circuits. The 2-wire auto-return control opens when the switch is closed and returns the valve toward closed when the switch is opened. Power is automatically cut at the end positions. The brass body uses a PTFE sealing ring and is rated for a maximum operating pressure of 16 bar. Confirm the thread, pressure, temperature, and electrical rating for your exact valve before installation.\u003c\/p\u003e\n\u003ch2 class=\"jfmsv-heading\"\u003eHOW IT WORKS\u003c\/h2\u003e\n\u003cdiv class=\"jfmsv-working-grid\"\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/JFMSV10096.gif\" alt=\"How the motorized ball valve operates\" loading=\"lazy\"\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/JFMSV10096-2.gif\" alt=\"Motorized ball valve operation diagram\" loading=\"lazy\"\u003e\n\u003c\/div\u003e\n\u003ch2 class=\"jfmsv-heading\"\u003eFEATURES\u003c\/h2\u003e\n\u003cimg class=\"jfmsv-feature-image-slot\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/features-JFMSV10096.jpg\" alt=\"Features of the JFMSV series motorized ball valve\" loading=\"lazy\"\u003e\n\u003ch2 class=\"jfmsv-heading\"\u003eAPPLICATIONS\u003c\/h2\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" alt=\"Typical motorized ball valve applications\" style=\"display:block;width:100%;height:auto;border:0;margin:0 0 12px;\"\u003e\n\u003cp\u003eUse in compatible non-potable water circulation, hydronic heating and cooling loops, and systems using water mixed with up to 50% ethylene glycol. Select the T-port orientation and control method to match the system flow path.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNot for drinking-water service.\u003c\/strong\u003e Brass valves may contain lead; see the WARNING section.\u003c\/p\u003e\n\u003ch2 class=\"jfmsv-heading\"\u003eSPECIFICATIONS\u003c\/h2\u003e\n\u003cdiv style=\"width:100%;max-width:100%;\"\u003e\u003ctable class=\"jfmsv-specs\"\u003e\n\u003ctr\u003e\n\u003cth style=\"width:17%;text-align:left;background:#f5f7f9;font-weight:700;padding:10px 12px;border:1px solid #d9e0e6;\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003eUSS-MSV10098 (NPT), USS-MSV10098-G (G)\u003c\/td\u003e\n\u003cth style=\"width:17%;text-align:left;background:#f5f7f9;font-weight:700;padding:10px 12px;border:1px solid #d9e0e6;\"\u003eNominal size\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003e1 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:17%;text-align:left;background:#f5f7f9;font-weight:700;padding:10px 12px;border:1px solid #d9e0e6;\"\u003eValve configuration\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003e3-way T-port\u003c\/td\u003e\n\u003cth style=\"width:17%;text-align:left;background:#f5f7f9;font-weight:700;padding:10px 12px;border:1px solid #d9e0e6;\"\u003ePort type\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003eStandard port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:17%;text-align:left;background:#f5f7f9;font-weight:700;padding:10px 12px;border:1px solid #d9e0e6;\"\u003eControl type\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003e2 Wire\u003c\/td\u003e\n\u003cth style=\"width:17%;text-align:left;background:#f5f7f9;font-weight:700;padding:10px 12px;border:1px solid #d9e0e6;\"\u003eVoltage\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003eAC 110-230V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:17%;text-align:left;background:#f5f7f9;font-weight:700;padding:10px 12px;border:1px solid #d9e0e6;\"\u003eFlow aperture\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003e19 mm\u003c\/td\u003e\n\u003cth style=\"width:17%;text-align:left;background:#f5f7f9;font-weight:700;padding:10px 12px;border:1px solid #d9e0e6;\"\u003eValve body\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003eBrass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:17%;text-align:left;background:#f5f7f9;font-weight:700;padding:10px 12px;border:1px solid #d9e0e6;\"\u003eSeal material\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003ePTFE\u003c\/td\u003e\n\u003cth style=\"width:17%;text-align:left;background:#f5f7f9;font-weight:700;padding:10px 12px;border:1px solid #d9e0e6;\"\u003eMaximum operating pressure\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003e16 bar (232 psi)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:17%;text-align:left;background:#f5f7f9;font-weight:700;padding:10px 12px;border:1px solid #d9e0e6;\"\u003eMedia temperature\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003e0–90 °C (32–194 °F)\u003c\/td\u003e\n\u003cth style=\"width:17%;text-align:left;background:#f5f7f9;font-weight:700;padding:10px 12px;border:1px solid #d9e0e6;\"\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003e0–60 °C (32–140 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:17%;text-align:left;background:#f5f7f9;font-weight:700;padding:10px 12px;border:1px solid #d9e0e6;\"\u003eEnclosure rating\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003eIP54\u003c\/td\u003e\n\u003cth style=\"width:17%;text-align:left;background:#f5f7f9;font-weight:700;padding:10px 12px;border:1px solid #d9e0e6;\"\u003eOperating torque\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003e6 Nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:17%;text-align:left;background:#f5f7f9;font-weight:700;padding:10px 12px;border:1px solid #d9e0e6;\"\u003eTravel time\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003e6–15 s\u003c\/td\u003e\n\u003cth style=\"width:17%;text-align:left;background:#f5f7f9;font-weight:700;padding:10px 12px;border:1px solid #d9e0e6;\"\u003eRated power\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003e7.5 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:17%;text-align:left;background:#f5f7f9;font-weight:700;padding:10px 12px;border:1px solid #d9e0e6;\"\u003eCompatible media\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003eWater or up to 50% ethylene glycol solution\u003c\/td\u003e\n\u003cth style=\"width:17%;text-align:left;background:#f5f7f9;font-weight:700;padding:10px 12px;border:1px solid #d9e0e6;\"\u003eService life\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003eUp to 100,000 cycles (listed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch2 class=\"jfmsv-heading\"\u003eFAQ\u003c\/h2\u003e\n\u003cdiv class=\"jfmsv-faq\"\u003e\n\u003cstrong\u003eWhat does the T-port configuration do?\u003c\/strong\u003e\u003cp style=\"margin:0;\"\u003eThe ball's T-shaped passage routes flow between three ports. Confirm the port orientation and flow direction against your piping layout and the manual diagrams.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"jfmsv-faq\"\u003e\n\u003cstrong\u003eHow does this wiring type operate?\u003c\/strong\u003e\u003cp style=\"margin:0;\"\u003eWith the 2-wire auto-return model, closing the switch opens the valve; opening the switch closes it. Follow the wiring diagram in the manual.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"jfmsv-faq\"\u003e\n\u003cstrong\u003eCan I use it with ethylene glycol?\u003c\/strong\u003e\u003cp style=\"margin:0;\"\u003eThe supplied product data lists water and a solution containing up to 50% ethylene glycol. Confirm chemical compatibility with all system materials and stay within the rated pressure and temperature limits.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch2 class=\"jfmsv-heading\" style=\"border-left-color:#b13b35;\"\u003eWARNING\u003c\/h2\u003e\n\u003cul style=\"padding-left:22px;margin:0 0 18px;\"\u003e\n\u003cli\u003eBrass valves may contain lead. Do not use this valve for drinking-water service.\u003c\/li\u003e\n\u003cli\u003eDisconnect the power supply before wiring or servicing. Use the voltage listed in the specifications and verify the wiring before connecting the supply.\u003c\/li\u003e\n\u003cli\u003eThe manual instructs that the valve remain powered for at least 1 minute. Follow the wiring diagram and instructions before operation.\u003c\/li\u003e\n\u003cli\u003eDo not exceed 16 bar, 0–90 °C media temperature, or 0–60 °C ambient temperature. IP54 protects against dust ingress and splashing water; it is not an immersion rating.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"jfmsv-heading\"\u003eMANUAL DOWNLOAD\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/Manual-JFMSV10096.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eDownload the 3-Way Motorized Ball Valve Manual (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/body\u003e","brand":"U.S. Solid","offers":[{"title":"NPT","offer_id":49166893515007,"sku":"JFMSV10098","price":55.67,"currency_code":"USD","in_stock":true},{"title":"G","offer_id":49166893547775,"sku":"JFMSV10098-G","price":55.67,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/1_2eff13d0-370b-4678-8bad-d221e7e55283.jpg?v=1792474698"},{"product_id":"1-2-304-stainless-steel-motorized-ball-valve-3-piece-5-wire-auto-return-normally-closed-110-230-v-ac-ip67-full-port-manual-override","title":"1\/2\" 304 Stainless Steel Motorized Ball Valve, 3-Piece, 5-Wire Auto Return, Normally Closed, 110-230 V AC, IP67, Full Port, Manual Override","description":"\u003cdiv class=\"product-description\" style=\"font-family: Arial, Helvetica, sans-serif; color: #000; line-height: 1.6; width: 100%;\"\u003e\n\u003cstyle\u003e    .product-description, .product-description * { box-sizing: border-box; }\n    .product-description { width: 100% !important; max-width: 100% !important; overflow-x: hidden !important; }\n    .product-description img { max-width: 100% !important; }\n    .product-description table { width: 100% !important; max-width: 100% !important; min-width: 0 !important; table-layout: fixed !important; border-collapse: collapse; }\n    .product-description th, .product-description td { overflow-wrap: anywhere; word-break: break-word; }\n    .product-description .wiring-layout { width: 100%; max-width: 100%; }\n    @media screen and (max-width: 700px) {\n      .product-description th, .product-description td { padding: 6px !important; font-size: 12px !important; }\n      .product-description .wiring-layout { display: block; }\n      .product-description .wiring-visual { width: 100%; }\n    }\n    .wiring-layout { display: flex; align-items: stretch; gap: 24px; width: 100%; }\n    .wiring-visual { flex: 0 0 48%; aspect-ratio: 1 \/ 1; display: flex; align-items: center; justify-content: center; overflow: hidden; }\n    .wiring-visual img { display: block; width: 100% !important; height: 100% !important; object-fit: contain; margin: 0 !important; border: 0 !important; outline: 0; box-shadow: none; }\n    .wiring-copy { flex: 1 1 0; min-width: 0; display: block; padding: 28px; }\n    .wiring-copy p { margin: 100px 0 0; font-size: 18px; line-height: 1.8; }\n    .wiring-title { width: 100%; margin: 0 0 20px; padding: 14px 20px; background: #7abd1c; border: 1px solid #4a4a4a; border-radius: 10px; color: #fff; font-size: 32px; line-height: 1.25; font-weight: 700; font-style: italic; text-align: center; }\n    @media screen and (max-width: 768px) {\n      .wiring-layout { display: block; }\n      .wiring-visual { width: 100%; margin-bottom: 16px; }\n      .wiring-copy { display: block; padding: 20px; border: 0; }\n      .wiring-copy p { margin-top: 20px; font-size: 16px; line-height: 1.7; }\n      .wiring-title { font-size: 24px; padding: 12px 14px; }\n    }\n  \u003c\/style\u003e\n\n  \u003csection style=\"margin:0 0 24px;\"\u003e\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage-3piece.jpg\" alt='U.S. Solid 1\/2\" 304 Stainless Steel Motorized Ball Valve, 3-Piece, 5-Wire Auto Return, Normally Closed, 12-24 V DC \/ 24 V AC, IP67, Full Port, Manual Override' style=\"border:0 !important;outline:0;box-shadow:none;display:block;width:100%;height:auto;\"\u003e\u003c\/section\u003e\u003csection style=\"margin:0 0 24px;\"\u003e\u003ch2 style=\"font-family: Arial, Helvetica, sans-serif !important; font-weight: 700 !important; font-size: 26px; margin: 0 0 12px;\"\u003eINTRODUCTION\u003c\/h2\u003e\n\u003cp style=\"margin:0 0 12px;\"\u003eThe U.S. Solid 1\/2 in motorized ball valve has a 304 stainless steel 3-piece body that is corrosion-resistant and designed for reliable fluid control applications. The bolted body unbolts into three pieces so the center ball and PTFE seats can be cleaned or reseated in line without cutting the pipe. It uses a 5-wire auto return, normally closed design: energize to open, and on power loss an internal capacitor drives the valve back to the fully closed position for safe shutoff, while the signal wires report open or closed status to your PLC, controller, or panel. A top indicator shows valve position at a glance, and a manual override with the included hex key works the valve by hand during a power outage. The full-port bore handles up to 1.6 MPa (232 psi) for water and air lines, filtration, dosing, and other automated fluid control systems.\u003c\/p\u003e\u003c\/section\u003e\u003csection style=\"margin:0 0 24px;\"\u003e\u003ch2 style=\"font-family: Arial, Helvetica, sans-serif !important; font-weight: 700 !important; font-size: 26px; margin: 0 0 12px;\"\u003eFEATURES\u003c\/h2\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/features-3%20pieces-AC110-230V.jpg\" alt=\"JFMSV55009 product features\" style=\"border:0 !important;outline:0;box-shadow:none;display:block;width:100%;height:auto;margin-bottom:16px;\"\u003e\u003c\/section\u003e\u003csection style=\"margin:0 0 24px;\"\u003e\u003ch2 style=\"font-family: Arial, Helvetica, sans-serif !important; font-weight: 700 !important; font-size: 26px; margin: 0 0 12px;\"\u003eAPPLICATIONS\u003c\/h2\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application-3%20pieces.jpg\" alt=\"Typical applications for JFMSV55009\" style=\"border:0 !important;outline:0;box-shadow:none;display:block;width:100%;height:auto;margin-bottom:12px;\"\u003e\u003cp style=\"margin:0;\"\u003eSuitable for compatible water and air lines, filtration, process-water systems, dosing, HVAC, irrigation, and industrial fluid control. Confirm media compatibility and the rated pressure and temperature before installation.\u003c\/p\u003e\u003c\/section\u003e\u003csection style=\"margin:0 0 24px;\"\u003e\u003ch2 style=\"font-family: Arial, Helvetica, sans-serif !important; font-weight: 700 !important; font-size: 26px; margin: 0 0 12px;\"\u003eSPECIFICATIONS\u003c\/h2\u003e\n\u003cdiv style=\"width:100%;max-width:100%;overflow:hidden;\"\u003e\u003ctable style=\"width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;\"\u003e\n\u003ctr\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003eUSS-MSV55009\u003c\/td\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003eU.S. Solid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003eValve Material\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003e304 Stainless Steel\u003c\/td\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003eBall Seat\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003ePTFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003eBody\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003e3-Piece bolted\u003c\/td\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003ePort Size\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003e1\/2 in NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003eOrifice Size\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003e15 mm\u003c\/td\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003eOpen\/Close Time\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003e12 s or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003eWorking Voltage\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003eAC 110-230V\u003c\/td\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003eMax Torque\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003e15 Nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003eMax Working Pressure\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003e1.6 MPa (232 psi)\u003c\/td\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003eMedia Temperature\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003e2°C to 90°C (36°F to 194°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003eAmbient Temperature\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003e-15°C to 50°C (5°F to 122°F)\u003c\/td\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003eService Life\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003e70,000 cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003eDefault State\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003eNormally Closed\u003c\/td\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003eWiring Type\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003e5-Wire Auto Return + Indicator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003eEnclosure Rating\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003eIP67\u003c\/td\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003eBore Type\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003eFull Port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"margin: 0 0 24px;\"\u003e\n    \u003ch2 style=\"font-family: Arial, Helvetica, sans-serif !important; font-weight: 700 !important; font-size: 26px; margin: 0 0 12px;\"\u003eDIMENSIONS\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/3-piece%20size.png\" alt=\"JFMSV55009 product dimensions\" style=\"border: 0 !important; outline: 0; box-shadow: none; display: block; width: 100%; height: auto; margin-bottom: 16px;\"\u003e\n    \u003cp style=\"margin: 0 0 12px;\"\u003eThe following dimensions apply to model JFMSV55009. All dimensions are in mm unless otherwise specified.\u003c\/p\u003e\n    \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n      \u003ctable style=\"width: 100%; min-width: 760px; border-collapse: collapse; table-layout: fixed; font-size: 16px;\"\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 22%; background: #f0f0f0; padding: 11px 10px; text-align: left; border-bottom: 1px dashed #555;\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"width: 28%; padding: 11px 10px; border-bottom: 1px dashed #555;\"\u003eJFMSV55009\u003c\/td\u003e\n\u003cth style=\"width: 22%; background: #f0f0f0; padding: 11px 10px; text-align: left; border-bottom: 1px dashed #555;\"\u003eSize\u003c\/th\u003e\n\u003ctd style=\"width: 28%; padding: 11px 10px; border-bottom: 1px dashed #555;\"\u003e1\/2\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 22%; background: #f0f0f0; padding: 11px 10px; text-align: left; border-bottom: 1px dashed #555;\"\u003eA\u003c\/th\u003e\n\u003ctd style=\"width: 28%; padding: 11px 10px; border-bottom: 1px dashed #555;\"\u003e92.6 mm\u003c\/td\u003e\n\u003cth style=\"width: 22%; background: #f0f0f0; padding: 11px 10px; text-align: left; border-bottom: 1px dashed #555;\"\u003eB\u003c\/th\u003e\n\u003ctd style=\"width: 28%; padding: 11px 10px; border-bottom: 1px dashed #555;\"\u003e75.7 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 22%; background: #f0f0f0; padding: 11px 10px; text-align: left; border-bottom: 1px dashed #555;\"\u003eC\u003c\/th\u003e\n\u003ctd style=\"width: 28%; padding: 11px 10px; border-bottom: 1px dashed #555;\"\u003e80.4 mm\u003c\/td\u003e\n\u003cth style=\"width: 22%; background: #f0f0f0; padding: 11px 10px; text-align: left; border-bottom: 1px dashed #555;\"\u003eD1 ± 0.5\u003c\/th\u003e\n\u003ctd style=\"width: 28%; padding: 11px 10px; border-bottom: 1px dashed #555;\"\u003e1\/2\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 22%; background: #f0f0f0; padding: 11px 10px; text-align: left; border-bottom: 1px dashed #555;\"\u003ed1 ± 0.5\u003c\/th\u003e\n\u003ctd style=\"width: 28%; padding: 11px 10px; border-bottom: 1px dashed #555;\"\u003e15 mm\u003c\/td\u003e\n\u003cth style=\"width: 22%; background: #f0f0f0; padding: 11px 10px; text-align: left; border-bottom: 1px dashed #555;\"\u003eL1 ± 2\u003c\/th\u003e\n\u003ctd style=\"width: 28%; padding: 11px 10px; border-bottom: 1px dashed #555;\"\u003e68 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 22%; background: #f0f0f0; padding: 11px 10px; text-align: left; border-bottom: 1px dashed #555;\"\u003eL2 ± 1\u003c\/th\u003e\n\u003ctd style=\"width: 28%; padding: 11px 10px; border-bottom: 1px dashed #555;\"\u003e14 mm\u003c\/td\u003e\n\u003cth style=\"width: 22%; background: #f0f0f0; padding: 11px 10px; text-align: left; border-bottom: 1px dashed #555;\"\u003eH1 ± 2\u003c\/th\u003e\n\u003ctd style=\"width: 28%; padding: 11px 10px; border-bottom: 1px dashed #555;\"\u003e123.4 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003c\/table\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\u003csection style=\"margin:0 0 24px;\"\u003e\u003ch2 style=\"font-family: Arial, Helvetica, sans-serif !important; font-weight: 700 !important; font-size: 26px; margin: 0 0 12px;\"\u003eWIRING INSTRUCTIONS\u003c\/h2\u003e\n\u003cdiv class=\"wiring-layout\"\u003e\n\u003cdiv class=\"wiring-visual\"\u003e\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/5%20wire%20auto%20return.png\" alt=\"5-wire auto-return wiring diagram\" style=\"border:0 !important;outline:0;box-shadow:none;display:block;width:100%;height:auto;margin-bottom:16px;\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"wiring-copy\"\u003e\n\u003cdiv class=\"wiring-title\"\u003e5 Wire (Auto Return + Indicator)\u003c\/div\u003e\n\u003cp\u003eFor this normally closed model, energizing the actuator opens the valve. If power is lost, the internal capacitor returns it to the fully closed position. Signal wires report the open and closed positions. Use the supplied wiring diagram to identify terminals, confirm the AC 110V-230V supply, and disconnect power before wiring.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"margin:0;\"\u003e\u003ch2 style=\"font-family: Arial, Helvetica, sans-serif !important; font-weight: 700 !important; font-size: 26px; margin: 0 0 12px;\"\u003eMANUAL DOWNLOAD\u003c\/h2\u003e\n\u003cp style=\"margin:0;\"\u003e\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/Manual-JFMSV40081.pdf\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"color:#000;text-decoration:underline;\"\u003eDownload the User Manual\u003c\/a\u003e\u003c\/p\u003e\u003c\/section\u003e\n\n\u003c\/div\u003e","brand":"U.S. Solid","offers":[{"title":"Default Title","offer_id":50721721516287,"sku":"JFMSV55009","price":212.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/jfmsv55009-1.jpg?v=1792486646"},{"product_id":"3-4-304-stainless-steel-motorized-ball-valve-3-piece-5-wire-auto-return-normally-closed-110-230-v-ac-ip67-full-port-manual-override","title":"3\/4\" 304 Stainless Steel Motorized Ball Valve, 3-Piece, 5-Wire Auto Return, Normally Closed, 110-230 V AC, IP67, Full Port, Manual Override","description":"\u003cdiv class=\"product-description\" style=\"font-family: Arial, Helvetica, sans-serif; color: #000; line-height: 1.6; width: 100%;\"\u003e\n\u003cstyle\u003e    .product-description, .product-description * { box-sizing: border-box; }\n    .product-description { width: 100% !important; max-width: 100% !important; overflow-x: hidden !important; }\n    .product-description img { max-width: 100% !important; }\n    .product-description table { width: 100% !important; max-width: 100% !important; min-width: 0 !important; table-layout: fixed !important; border-collapse: collapse; }\n    .product-description th, .product-description td { overflow-wrap: anywhere; word-break: break-word; }\n    .product-description .wiring-layout { width: 100%; max-width: 100%; }\n    @media screen and (max-width: 700px) {\n      .product-description th, .product-description td { padding: 6px !important; font-size: 12px !important; }\n      .product-description .wiring-layout { display: block; }\n      .product-description .wiring-visual { width: 100%; }\n    }\n    .wiring-layout { display: flex; align-items: stretch; gap: 24px; width: 100%; }\n    .wiring-visual { flex: 0 0 48%; aspect-ratio: 1 \/ 1; display: flex; align-items: center; justify-content: center; overflow: hidden; }\n    .wiring-visual img { display: block; width: 100% !important; height: 100% !important; object-fit: contain; margin: 0 !important; border: 0 !important; outline: 0; box-shadow: none; }\n    .wiring-copy { flex: 1 1 0; min-width: 0; display: block; padding: 28px; }\n    .wiring-copy p { margin: 100px 0 0; font-size: 18px; line-height: 1.8; }\n    .wiring-title { width: 100%; margin: 0 0 20px; padding: 14px 20px; background: #7abd1c; border: 1px solid #4a4a4a; border-radius: 10px; color: #fff; font-size: 32px; line-height: 1.25; font-weight: 700; font-style: italic; text-align: center; }\n    @media screen and (max-width: 768px) {\n      .wiring-layout { display: block; }\n      .wiring-visual { width: 100%; margin-bottom: 16px; }\n      .wiring-copy { display: block; padding: 20px; border: 0; }\n      .wiring-copy p { margin-top: 20px; font-size: 16px; line-height: 1.7; }\n      .wiring-title { font-size: 24px; padding: 12px 14px; }\n    }\n  \u003c\/style\u003e\n\n  \u003csection style=\"margin:0 0 24px;\"\u003e\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage-3piece.jpg\" alt='U.S. Solid 3\/4\" 304 Stainless Steel Motorized Ball Valve, 3-Piece, 5-Wire Auto Return, Normally Closed, 12-24 V DC \/ 24 V AC, IP67, Full Port, Manual Override' style=\"border:0 !important;outline:0;box-shadow:none;display:block;width:100%;height:auto;\"\u003e\u003c\/section\u003e\u003csection style=\"margin:0 0 24px;\"\u003e\u003ch2 style=\"font-family: Arial, Helvetica, sans-serif !important; font-weight: 700 !important; font-size: 26px; margin: 0 0 12px;\"\u003eINTRODUCTION\u003c\/h2\u003e\n\u003cp style=\"margin:0 0 12px;\"\u003eThe U.S. Solid 3\/4 in motorized ball valve has a 304 stainless steel 3-piece body that is corrosion-resistant and designed for reliable fluid control applications. The bolted body unbolts into three pieces so the center ball and PTFE seats can be cleaned or reseated in line without cutting the pipe. It uses a 5-wire auto return, normally closed design: energize to open, and on power loss an internal capacitor drives the valve back to the fully closed position for safe shutoff, while the signal wires report open or closed status to your PLC, controller, or panel. A top indicator shows valve position at a glance, and a manual override with the included hex key works the valve by hand during a power outage. The full-port bore handles up to 1.6 MPa (232 psi) for water and air lines, filtration, dosing, and other automated fluid control systems.\u003c\/p\u003e\u003c\/section\u003e\u003csection style=\"margin:0 0 24px;\"\u003e\u003ch2 style=\"font-family: Arial, Helvetica, sans-serif !important; font-weight: 700 !important; font-size: 26px; margin: 0 0 12px;\"\u003eFEATURES\u003c\/h2\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/features-3%20pieces-AC110-230V.jpg\" alt=\"JFMSV55010 product features\" style=\"border:0 !important;outline:0;box-shadow:none;display:block;width:100%;height:auto;margin-bottom:16px;\"\u003e\u003c\/section\u003e\u003csection style=\"margin:0 0 24px;\"\u003e\u003ch2 style=\"font-family: Arial, Helvetica, sans-serif !important; font-weight: 700 !important; font-size: 26px; margin: 0 0 12px;\"\u003eAPPLICATIONS\u003c\/h2\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application-3%20pieces.jpg\" alt=\"Typical applications for JFMSV55010\" style=\"border:0 !important;outline:0;box-shadow:none;display:block;width:100%;height:auto;margin-bottom:12px;\"\u003e\u003cp style=\"margin:0;\"\u003eSuitable for compatible water and air lines, filtration, process-water systems, dosing, HVAC, irrigation, and industrial fluid control. Confirm media compatibility and the rated pressure and temperature before installation.\u003c\/p\u003e\u003c\/section\u003e\u003csection style=\"margin:0 0 24px;\"\u003e\u003ch2 style=\"font-family: Arial, Helvetica, sans-serif !important; font-weight: 700 !important; font-size: 26px; margin: 0 0 12px;\"\u003eSPECIFICATIONS\u003c\/h2\u003e\n\u003cdiv style=\"width:100%;max-width:100%;overflow:hidden;\"\u003e\u003ctable style=\"width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;\"\u003e\n\u003ctr\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003eUSS-MSV55010\u003c\/td\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003eU.S. Solid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003eValve Material\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003e304 Stainless Steel\u003c\/td\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003eBall Seat\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003ePTFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003eBody\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003e3-Piece bolted\u003c\/td\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003ePort Size\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003e3\/4 in NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003eOrifice Size\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003e20 mm\u003c\/td\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003eOpen\/Close Time\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003e12 s or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003eWorking Voltage\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003eAC 110-230V\u003c\/td\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003eMax Torque\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003e15 Nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003eMax Working Pressure\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003e1.6 MPa (232 psi)\u003c\/td\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003eMedia Temperature\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003e2°C to 90°C (36°F to 194°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003eAmbient Temperature\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003e-15°C to 50°C (5°F to 122°F)\u003c\/td\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003eService Life\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003e70,000 cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003eDefault State\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003eNormally Closed\u003c\/td\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003eWiring Type\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003e5-Wire Auto Return + Indicator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003eEnclosure Rating\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003eIP67\u003c\/td\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003eBore Type\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003eFull Port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"margin: 0 0 24px;\"\u003e\n    \u003ch2 style=\"font-family: Arial, Helvetica, sans-serif !important; font-weight: 700 !important; font-size: 26px; margin: 0 0 12px;\"\u003eDIMENSIONS\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/3-piece%20size.png\" alt=\"JFMSV55010 product dimensions\" style=\"border: 0 !important; outline: 0; box-shadow: none; display: block; width: 100%; height: auto; margin-bottom: 16px;\"\u003e\n    \u003cp style=\"margin: 0 0 12px;\"\u003eThe following dimensions apply to model JFMSV55010. All dimensions are in mm unless otherwise specified.\u003c\/p\u003e\n    \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n      \u003ctable style=\"width: 100%; min-width: 760px; border-collapse: collapse; table-layout: fixed; font-size: 16px;\"\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 22%; background: #f0f0f0; padding: 11px 10px; text-align: left; border-bottom: 1px dashed #555;\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"width: 28%; padding: 11px 10px; border-bottom: 1px dashed #555;\"\u003eJFMSV55010\u003c\/td\u003e\n\u003cth style=\"width: 22%; background: #f0f0f0; padding: 11px 10px; text-align: left; border-bottom: 1px dashed #555;\"\u003eSize\u003c\/th\u003e\n\u003ctd style=\"width: 28%; padding: 11px 10px; border-bottom: 1px dashed #555;\"\u003e3\/4\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 22%; background: #f0f0f0; padding: 11px 10px; text-align: left; border-bottom: 1px dashed #555;\"\u003eA\u003c\/th\u003e\n\u003ctd style=\"width: 28%; padding: 11px 10px; border-bottom: 1px dashed #555;\"\u003e92.6 mm\u003c\/td\u003e\n\u003cth style=\"width: 22%; background: #f0f0f0; padding: 11px 10px; text-align: left; border-bottom: 1px dashed #555;\"\u003eB\u003c\/th\u003e\n\u003ctd style=\"width: 28%; padding: 11px 10px; border-bottom: 1px dashed #555;\"\u003e75.7 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 22%; background: #f0f0f0; padding: 11px 10px; text-align: left; border-bottom: 1px dashed #555;\"\u003eC\u003c\/th\u003e\n\u003ctd style=\"width: 28%; padding: 11px 10px; border-bottom: 1px dashed #555;\"\u003e80.4 mm\u003c\/td\u003e\n\u003cth style=\"width: 22%; background: #f0f0f0; padding: 11px 10px; text-align: left; border-bottom: 1px dashed #555;\"\u003eD1 ± 0.5\u003c\/th\u003e\n\u003ctd style=\"width: 28%; padding: 11px 10px; border-bottom: 1px dashed #555;\"\u003e3\/4\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 22%; background: #f0f0f0; padding: 11px 10px; text-align: left; border-bottom: 1px dashed #555;\"\u003ed1 ± 0.5\u003c\/th\u003e\n\u003ctd style=\"width: 28%; padding: 11px 10px; border-bottom: 1px dashed #555;\"\u003e20 mm\u003c\/td\u003e\n\u003cth style=\"width: 22%; background: #f0f0f0; padding: 11px 10px; text-align: left; border-bottom: 1px dashed #555;\"\u003eL1 ± 2\u003c\/th\u003e\n\u003ctd style=\"width: 28%; padding: 11px 10px; border-bottom: 1px dashed #555;\"\u003e80 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 22%; background: #f0f0f0; padding: 11px 10px; text-align: left; border-bottom: 1px dashed #555;\"\u003eL2 ± 1\u003c\/th\u003e\n\u003ctd style=\"width: 28%; padding: 11px 10px; border-bottom: 1px dashed #555;\"\u003e16 mm\u003c\/td\u003e\n\u003cth style=\"width: 22%; background: #f0f0f0; padding: 11px 10px; text-align: left; border-bottom: 1px dashed #555;\"\u003eH1 ± 2\u003c\/th\u003e\n\u003ctd style=\"width: 28%; padding: 11px 10px; border-bottom: 1px dashed #555;\"\u003e127.4 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003c\/table\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\u003csection style=\"margin:0 0 24px;\"\u003e\u003ch2 style=\"font-family: Arial, Helvetica, sans-serif !important; font-weight: 700 !important; font-size: 26px; margin: 0 0 12px;\"\u003eWIRING INSTRUCTIONS\u003c\/h2\u003e\n\u003cdiv class=\"wiring-layout\"\u003e\n\u003cdiv class=\"wiring-visual\"\u003e\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/5%20wire%20auto%20return.png\" alt=\"5-wire auto-return wiring diagram\" style=\"border:0 !important;outline:0;box-shadow:none;display:block;width:100%;height:auto;margin-bottom:16px;\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"wiring-copy\"\u003e\n\u003cdiv class=\"wiring-title\"\u003e5 Wire (Auto Return + Indicator)\u003c\/div\u003e\n\u003cp\u003eFor this normally closed model, energizing the actuator opens the valve. If power is lost, the internal capacitor returns it to the fully closed position. Signal wires report the open and closed positions. Use the supplied wiring diagram to identify terminals, confirm the AC 110V-230V supply, and disconnect power before wiring.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"margin:0;\"\u003e\u003ch2 style=\"font-family: Arial, Helvetica, sans-serif !important; font-weight: 700 !important; font-size: 26px; margin: 0 0 12px;\"\u003eMANUAL DOWNLOAD\u003c\/h2\u003e\n\u003cp style=\"margin:0;\"\u003e\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/Manual-JFMSV40081.pdf\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"color:#000;text-decoration:underline;\"\u003eDownload the User Manual\u003c\/a\u003e\u003c\/p\u003e\u003c\/section\u003e\n\n\u003c\/div\u003e","brand":"U.S. Solid","offers":[{"title":"Default Title","offer_id":50721721745663,"sku":"JFMSV55010","price":219.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/jfmsv55010-1.jpg?v=1792486646"},{"product_id":"1-304-stainless-steel-motorized-ball-valve-3-piece-5-wire-auto-return-normally-closed-110-230-v-ac-ip67-full-port-manual-override","title":"1\" 304 Stainless Steel Motorized Ball Valve, 3-Piece, 5-Wire Auto Return, Normally Closed, 110-230 V AC, IP67, Full Port, Manual Override","description":"\u003cdiv class=\"product-description\" style=\"font-family: Arial, Helvetica, sans-serif; color: #000; line-height: 1.6; width: 100%;\"\u003e\n\u003cstyle\u003e    .product-description, .product-description * { box-sizing: border-box; }\n    .product-description { width: 100% !important; max-width: 100% !important; overflow-x: hidden !important; }\n    .product-description img { max-width: 100% !important; }\n    .product-description table { width: 100% !important; max-width: 100% !important; min-width: 0 !important; table-layout: fixed !important; border-collapse: collapse; }\n    .product-description th, .product-description td { overflow-wrap: anywhere; word-break: break-word; }\n    .product-description .wiring-layout { width: 100%; max-width: 100%; }\n    @media screen and (max-width: 700px) {\n      .product-description th, .product-description td { padding: 6px !important; font-size: 12px !important; }\n      .product-description .wiring-layout { display: block; }\n      .product-description .wiring-visual { width: 100%; }\n    }\n    .wiring-layout { display: flex; align-items: stretch; gap: 24px; width: 100%; }\n    .wiring-visual { flex: 0 0 48%; aspect-ratio: 1 \/ 1; display: flex; align-items: center; justify-content: center; overflow: hidden; }\n    .wiring-visual img { display: block; width: 100% !important; height: 100% !important; object-fit: contain; margin: 0 !important; border: 0 !important; outline: 0; box-shadow: none; }\n    .wiring-copy { flex: 1 1 0; min-width: 0; display: block; padding: 28px; }\n    .wiring-copy p { margin: 100px 0 0; font-size: 18px; line-height: 1.8; }\n    .wiring-title { width: 100%; margin: 0 0 20px; padding: 14px 20px; background: #7abd1c; border: 1px solid #4a4a4a; border-radius: 10px; color: #fff; font-size: 32px; line-height: 1.25; font-weight: 700; font-style: italic; text-align: center; }\n    @media screen and (max-width: 768px) {\n      .wiring-layout { display: block; }\n      .wiring-visual { width: 100%; margin-bottom: 16px; }\n      .wiring-copy { display: block; padding: 20px; border: 0; }\n      .wiring-copy p { margin-top: 20px; font-size: 16px; line-height: 1.7; }\n      .wiring-title { font-size: 24px; padding: 12px 14px; }\n    }\n  \u003c\/style\u003e\n\n  \u003csection style=\"margin:0 0 24px;\"\u003e\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage-3piece.jpg\" alt='U.S. Solid 1\" 304 Stainless Steel Motorized Ball Valve, 3-Piece, 5-Wire Auto Return, Normally Closed, 12-24 V DC \/ 24 V AC, IP67, Full Port, Manual Override' style=\"border:0 !important;outline:0;box-shadow:none;display:block;width:100%;height:auto;\"\u003e\u003c\/section\u003e\u003csection style=\"margin:0 0 24px;\"\u003e\u003ch2 style=\"font-family: Arial, Helvetica, sans-serif !important; font-weight: 700 !important; font-size: 26px; margin: 0 0 12px;\"\u003eINTRODUCTION\u003c\/h2\u003e\n\u003cp style=\"margin:0 0 12px;\"\u003eThe U.S. Solid 1 in motorized ball valve has a 304 stainless steel 3-piece body that is corrosion-resistant and designed for reliable fluid control applications. The bolted body unbolts into three pieces so the center ball and PTFE seats can be cleaned or reseated in line without cutting the pipe. It uses a 5-wire auto return, normally closed design: energize to open, and on power loss an internal capacitor drives the valve back to the fully closed position for safe shutoff, while the signal wires report open or closed status to your PLC, controller, or panel. A top indicator shows valve position at a glance, and a manual override with the included hex key works the valve by hand during a power outage. The full-port bore handles up to 1.6 MPa (232 psi) for water and air lines, filtration, dosing, and other automated fluid control systems.\u003c\/p\u003e\u003c\/section\u003e\u003csection style=\"margin:0 0 24px;\"\u003e\u003ch2 style=\"font-family: Arial, Helvetica, sans-serif !important; font-weight: 700 !important; font-size: 26px; margin: 0 0 12px;\"\u003eFEATURES\u003c\/h2\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/features-3%20pieces-AC110-230V.jpg\" alt=\"JFMSV55011 product features\" style=\"border:0 !important;outline:0;box-shadow:none;display:block;width:100%;height:auto;margin-bottom:16px;\"\u003e\u003c\/section\u003e\u003csection style=\"margin:0 0 24px;\"\u003e\u003ch2 style=\"font-family: Arial, Helvetica, sans-serif !important; font-weight: 700 !important; font-size: 26px; margin: 0 0 12px;\"\u003eAPPLICATIONS\u003c\/h2\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application-3%20pieces.jpg\" alt=\"Typical applications for JFMSV55011\" style=\"border:0 !important;outline:0;box-shadow:none;display:block;width:100%;height:auto;margin-bottom:12px;\"\u003e\u003cp style=\"margin:0;\"\u003eSuitable for compatible water and air lines, filtration, process-water systems, dosing, HVAC, irrigation, and industrial fluid control. Confirm media compatibility and the rated pressure and temperature before installation.\u003c\/p\u003e\u003c\/section\u003e\u003csection style=\"margin:0 0 24px;\"\u003e\u003ch2 style=\"font-family: Arial, Helvetica, sans-serif !important; font-weight: 700 !important; font-size: 26px; margin: 0 0 12px;\"\u003eSPECIFICATIONS\u003c\/h2\u003e\n\u003cdiv style=\"width:100%;max-width:100%;overflow:hidden;\"\u003e\u003ctable style=\"width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;\"\u003e\n\u003ctr\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003eUSS-MSV55011\u003c\/td\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003eU.S. Solid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003eValve Material\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003e304 Stainless Steel\u003c\/td\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003eBall Seat\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003ePTFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003eBody\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003e3-Piece bolted\u003c\/td\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003ePort Size\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003e1 in NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003eOrifice Size\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003e25 mm\u003c\/td\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003eOpen\/Close Time\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003e12 s or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003eWorking Voltage\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003eAC 110-230V\u003c\/td\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003eMax Torque\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003e15 Nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003eMax Working Pressure\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003e1.6 MPa (232 psi)\u003c\/td\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003eMedia Temperature\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003e2°C to 90°C (36°F to 194°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003eAmbient Temperature\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003e-15°C to 50°C (5°F to 122°F)\u003c\/td\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003eService Life\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003e70,000 cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003eDefault State\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003eNormally Closed\u003c\/td\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003eWiring Type\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003e5-Wire Auto Return + Indicator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003eEnclosure Rating\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003eIP67\u003c\/td\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003eBore Type\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003eFull Port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"margin: 0 0 24px;\"\u003e\n    \u003ch2 style=\"font-family: Arial, Helvetica, sans-serif !important; font-weight: 700 !important; font-size: 26px; margin: 0 0 12px;\"\u003eDIMENSIONS\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/3-piece%20size.png\" alt=\"JFMSV55011 product dimensions\" style=\"border: 0 !important; outline: 0; box-shadow: none; display: block; width: 100%; height: auto; margin-bottom: 16px;\"\u003e\n    \u003cp style=\"margin: 0 0 12px;\"\u003eThe following dimensions apply to model JFMSV55011. All dimensions are in mm unless otherwise specified.\u003c\/p\u003e\n    \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n      \u003ctable style=\"width: 100%; min-width: 760px; border-collapse: collapse; table-layout: fixed; font-size: 16px;\"\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 22%; background: #f0f0f0; padding: 11px 10px; text-align: left; border-bottom: 1px dashed #555;\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"width: 28%; padding: 11px 10px; border-bottom: 1px dashed #555;\"\u003eJFMSV55011\u003c\/td\u003e\n\u003cth style=\"width: 22%; background: #f0f0f0; padding: 11px 10px; text-align: left; border-bottom: 1px dashed #555;\"\u003eSize\u003c\/th\u003e\n\u003ctd style=\"width: 28%; padding: 11px 10px; border-bottom: 1px dashed #555;\"\u003e1\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 22%; background: #f0f0f0; padding: 11px 10px; text-align: left; border-bottom: 1px dashed #555;\"\u003eA\u003c\/th\u003e\n\u003ctd style=\"width: 28%; padding: 11px 10px; border-bottom: 1px dashed #555;\"\u003e92.6 mm\u003c\/td\u003e\n\u003cth style=\"width: 22%; background: #f0f0f0; padding: 11px 10px; text-align: left; border-bottom: 1px dashed #555;\"\u003eB\u003c\/th\u003e\n\u003ctd style=\"width: 28%; padding: 11px 10px; border-bottom: 1px dashed #555;\"\u003e75.7 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 22%; background: #f0f0f0; padding: 11px 10px; text-align: left; border-bottom: 1px dashed #555;\"\u003eC\u003c\/th\u003e\n\u003ctd style=\"width: 28%; padding: 11px 10px; border-bottom: 1px dashed #555;\"\u003e80.4 mm\u003c\/td\u003e\n\u003cth style=\"width: 22%; background: #f0f0f0; padding: 11px 10px; text-align: left; border-bottom: 1px dashed #555;\"\u003eD1 ± 0.5\u003c\/th\u003e\n\u003ctd style=\"width: 28%; padding: 11px 10px; border-bottom: 1px dashed #555;\"\u003e1\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 22%; background: #f0f0f0; padding: 11px 10px; text-align: left; border-bottom: 1px dashed #555;\"\u003ed1 ± 0.5\u003c\/th\u003e\n\u003ctd style=\"width: 28%; padding: 11px 10px; border-bottom: 1px dashed #555;\"\u003e25 mm\u003c\/td\u003e\n\u003cth style=\"width: 22%; background: #f0f0f0; padding: 11px 10px; text-align: left; border-bottom: 1px dashed #555;\"\u003eL1 ± 2\u003c\/th\u003e\n\u003ctd style=\"width: 28%; padding: 11px 10px; border-bottom: 1px dashed #555;\"\u003e87 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 22%; background: #f0f0f0; padding: 11px 10px; text-align: left; border-bottom: 1px dashed #555;\"\u003eL2 ± 1\u003c\/th\u003e\n\u003ctd style=\"width: 28%; padding: 11px 10px; border-bottom: 1px dashed #555;\"\u003e17 mm\u003c\/td\u003e\n\u003cth style=\"width: 22%; background: #f0f0f0; padding: 11px 10px; text-align: left; border-bottom: 1px dashed #555;\"\u003eH1 ± 2\u003c\/th\u003e\n\u003ctd style=\"width: 28%; padding: 11px 10px; border-bottom: 1px dashed #555;\"\u003e136.4 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003c\/table\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\u003csection style=\"margin:0 0 24px;\"\u003e\u003ch2 style=\"font-family: Arial, Helvetica, sans-serif !important; font-weight: 700 !important; font-size: 26px; margin: 0 0 12px;\"\u003eWIRING INSTRUCTIONS\u003c\/h2\u003e\n\u003cdiv class=\"wiring-layout\"\u003e\n\u003cdiv class=\"wiring-visual\"\u003e\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/5%20wire%20auto%20return.png\" alt=\"5-wire auto-return wiring diagram\" style=\"border:0 !important;outline:0;box-shadow:none;display:block;width:100%;height:auto;margin-bottom:16px;\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"wiring-copy\"\u003e\n\u003cdiv class=\"wiring-title\"\u003e5 Wire (Auto Return + Indicator)\u003c\/div\u003e\n\u003cp\u003eFor this normally closed model, energizing the actuator opens the valve. If power is lost, the internal capacitor returns it to the fully closed position. Signal wires report the open and closed positions. Use the supplied wiring diagram to identify terminals, confirm the AC 110V-230V supply, and disconnect power before wiring.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"margin:0;\"\u003e\u003ch2 style=\"font-family: Arial, Helvetica, sans-serif !important; font-weight: 700 !important; font-size: 26px; margin: 0 0 12px;\"\u003eMANUAL DOWNLOAD\u003c\/h2\u003e\n\u003cp style=\"margin:0;\"\u003e\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/Manual-JFMSV40081.pdf\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"color:#000;text-decoration:underline;\"\u003eDownload the User Manual\u003c\/a\u003e\u003c\/p\u003e\u003c\/section\u003e\n\n\u003c\/div\u003e","brand":"U.S. Solid","offers":[{"title":"Default Title","offer_id":50721721975039,"sku":"JFMSV55011","price":238.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/jfmsv55011-1.jpg?v=1792486649"},{"product_id":"1-1-4-304-stainless-steel-motorized-ball-valve-3-piece-5-wire-auto-return-normally-closed-110-230-v-ac-ip67-full-port-manual-override","title":"1-1\/4\" 304 Stainless Steel Motorized Ball Valve, 3-Piece, 5-Wire Auto Return, Normally Closed, 110-230 V AC, IP67, Full Port, Manual Override","description":"\u003cdiv class=\"product-description\" style=\"font-family: Arial, Helvetica, sans-serif; color: #000; line-height: 1.6; width: 100%;\"\u003e\n\u003cstyle\u003e    .product-description, .product-description * { box-sizing: border-box; }\n    .product-description { width: 100% !important; max-width: 100% !important; overflow-x: hidden !important; }\n    .product-description img { max-width: 100% !important; }\n    .product-description table { width: 100% !important; max-width: 100% !important; min-width: 0 !important; table-layout: fixed !important; border-collapse: collapse; }\n    .product-description th, .product-description td { overflow-wrap: anywhere; word-break: break-word; }\n    .product-description .wiring-layout { width: 100%; max-width: 100%; }\n    @media screen and (max-width: 700px) {\n      .product-description th, .product-description td { padding: 6px !important; font-size: 12px !important; }\n      .product-description .wiring-layout { display: block; }\n      .product-description .wiring-visual { width: 100%; }\n    }\n    .wiring-layout { display: flex; align-items: stretch; gap: 24px; width: 100%; }\n    .wiring-visual { flex: 0 0 48%; aspect-ratio: 1 \/ 1; display: flex; align-items: center; justify-content: center; overflow: hidden; }\n    .wiring-visual img { display: block; width: 100% !important; height: 100% !important; object-fit: contain; margin: 0 !important; border: 0 !important; outline: 0; box-shadow: none; }\n    .wiring-copy { flex: 1 1 0; min-width: 0; display: block; padding: 28px; }\n    .wiring-copy p { margin: 100px 0 0; font-size: 18px; line-height: 1.8; }\n    .wiring-title { width: 100%; margin: 0 0 20px; padding: 14px 20px; background: #7abd1c; border: 1px solid #4a4a4a; border-radius: 10px; color: #fff; font-size: 32px; line-height: 1.25; font-weight: 700; font-style: italic; text-align: center; }\n    @media screen and (max-width: 768px) {\n      .wiring-layout { display: block; }\n      .wiring-visual { width: 100%; margin-bottom: 16px; }\n      .wiring-copy { display: block; padding: 20px; border: 0; }\n      .wiring-copy p { margin-top: 20px; font-size: 16px; line-height: 1.7; }\n      .wiring-title { font-size: 24px; padding: 12px 14px; }\n    }\n  \u003c\/style\u003e\n\n  \u003csection style=\"margin:0 0 24px;\"\u003e\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage-3piece.jpg\" alt='U.S. Solid 1-1\/4\" 304 Stainless Steel Motorized Ball Valve, 3-Piece, 5-Wire Auto Return, Normally Closed, 12-24 V DC \/ 24 V AC, IP67, Full Port, Manual Override' style=\"border:0 !important;outline:0;box-shadow:none;display:block;width:100%;height:auto;\"\u003e\u003c\/section\u003e\u003csection style=\"margin:0 0 24px;\"\u003e\u003ch2 style=\"font-family: Arial, Helvetica, sans-serif !important; font-weight: 700 !important; font-size: 26px; margin: 0 0 12px;\"\u003eINTRODUCTION\u003c\/h2\u003e\n\u003cp style=\"margin:0 0 12px;\"\u003eThe U.S. Solid 1-1\/4 in motorized ball valve has a 304 stainless steel 3-piece body that is corrosion-resistant and designed for reliable fluid control applications. The bolted body unbolts into three pieces so the center ball and PTFE seats can be cleaned or reseated in line without cutting the pipe. It uses a 5-wire auto return, normally closed design: energize to open, and on power loss an internal capacitor drives the valve back to the fully closed position for safe shutoff, while the signal wires report open or closed status to your PLC, controller, or panel. A top indicator shows valve position at a glance, and a manual override with the included hex key works the valve by hand during a power outage. The full-port bore handles up to 1.6 MPa (232 psi) for water and air lines, filtration, dosing, and other automated fluid control systems.\u003c\/p\u003e\u003c\/section\u003e\u003csection style=\"margin:0 0 24px;\"\u003e\u003ch2 style=\"font-family: Arial, Helvetica, sans-serif !important; font-weight: 700 !important; font-size: 26px; margin: 0 0 12px;\"\u003eFEATURES\u003c\/h2\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/features-3%20pieces-AC110-230V.jpg\" alt=\"JFMSV55012 product features\" style=\"border:0 !important;outline:0;box-shadow:none;display:block;width:100%;height:auto;margin-bottom:16px;\"\u003e\u003c\/section\u003e\u003csection style=\"margin:0 0 24px;\"\u003e\u003ch2 style=\"font-family: Arial, Helvetica, sans-serif !important; font-weight: 700 !important; font-size: 26px; margin: 0 0 12px;\"\u003eAPPLICATIONS\u003c\/h2\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application-3%20pieces.jpg\" alt=\"Typical applications for JFMSV55012\" style=\"border:0 !important;outline:0;box-shadow:none;display:block;width:100%;height:auto;margin-bottom:12px;\"\u003e\u003cp style=\"margin:0;\"\u003eSuitable for compatible water and air lines, filtration, process-water systems, dosing, HVAC, irrigation, and industrial fluid control. Confirm media compatibility and the rated pressure and temperature before installation.\u003c\/p\u003e\u003c\/section\u003e\u003csection style=\"margin:0 0 24px;\"\u003e\u003ch2 style=\"font-family: Arial, Helvetica, sans-serif !important; font-weight: 700 !important; font-size: 26px; margin: 0 0 12px;\"\u003eSPECIFICATIONS\u003c\/h2\u003e\n\u003cdiv style=\"width:100%;max-width:100%;overflow:hidden;\"\u003e\u003ctable style=\"width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;\"\u003e\n\u003ctr\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003eUSS-MSV55012\u003c\/td\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003eU.S. Solid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003eValve Material\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003e304 Stainless Steel\u003c\/td\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003eBall Seat\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003ePTFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003eBody\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003e3-Piece bolted\u003c\/td\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003ePort Size\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003e1-1\/4 in NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003eOrifice Size\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003e32 mm\u003c\/td\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003eOpen\/Close Time\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003e12 s or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003eWorking Voltage\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003eAC 110-230V\u003c\/td\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003eMax Torque\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003e15 Nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003eMax Working Pressure\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003e1.6 MPa (232 psi)\u003c\/td\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003eMedia Temperature\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003e2°C to 90°C (36°F to 194°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003eAmbient Temperature\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003e-15°C to 50°C (5°F to 122°F)\u003c\/td\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003eService Life\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003e70,000 cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003eDefault State\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003eNormally Closed\u003c\/td\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003eWiring Type\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003e5-Wire Auto Return + Indicator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003eEnclosure Rating\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003eIP67\u003c\/td\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003eBore Type\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003eFull Port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"margin: 0 0 24px;\"\u003e\n    \u003ch2 style=\"font-family: Arial, Helvetica, sans-serif !important; font-weight: 700 !important; font-size: 26px; margin: 0 0 12px;\"\u003eDIMENSIONS\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/3-piece%20size.png\" alt=\"JFMSV55012 product dimensions\" style=\"border: 0 !important; outline: 0; box-shadow: none; display: block; width: 100%; height: auto; margin-bottom: 16px;\"\u003e\n    \u003cp style=\"margin: 0 0 12px;\"\u003eThe following dimensions apply to model JFMSV55012. All dimensions are in mm unless otherwise specified.\u003c\/p\u003e\n    \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n      \u003ctable style=\"width: 100%; min-width: 760px; border-collapse: collapse; table-layout: fixed; font-size: 16px;\"\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 22%; background: #f0f0f0; padding: 11px 10px; text-align: left; border-bottom: 1px dashed #555;\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"width: 28%; padding: 11px 10px; border-bottom: 1px dashed #555;\"\u003eJFMSV55012\u003c\/td\u003e\n\u003cth style=\"width: 22%; background: #f0f0f0; padding: 11px 10px; text-align: left; border-bottom: 1px dashed #555;\"\u003eSize\u003c\/th\u003e\n\u003ctd style=\"width: 28%; padding: 11px 10px; border-bottom: 1px dashed #555;\"\u003e1-1\/4\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 22%; background: #f0f0f0; padding: 11px 10px; text-align: left; border-bottom: 1px dashed #555;\"\u003eA\u003c\/th\u003e\n\u003ctd style=\"width: 28%; padding: 11px 10px; border-bottom: 1px dashed #555;\"\u003e92.6 mm\u003c\/td\u003e\n\u003cth style=\"width: 22%; background: #f0f0f0; padding: 11px 10px; text-align: left; border-bottom: 1px dashed #555;\"\u003eB\u003c\/th\u003e\n\u003ctd style=\"width: 28%; padding: 11px 10px; border-bottom: 1px dashed #555;\"\u003e75.7 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 22%; background: #f0f0f0; padding: 11px 10px; text-align: left; border-bottom: 1px dashed #555;\"\u003eC\u003c\/th\u003e\n\u003ctd style=\"width: 28%; padding: 11px 10px; border-bottom: 1px dashed #555;\"\u003e80.4 mm\u003c\/td\u003e\n\u003cth style=\"width: 22%; background: #f0f0f0; padding: 11px 10px; text-align: left; border-bottom: 1px dashed #555;\"\u003eD1 ± 0.5\u003c\/th\u003e\n\u003ctd style=\"width: 28%; padding: 11px 10px; border-bottom: 1px dashed #555;\"\u003e1-1\/4\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 22%; background: #f0f0f0; padding: 11px 10px; text-align: left; border-bottom: 1px dashed #555;\"\u003ed1 ± 0.5\u003c\/th\u003e\n\u003ctd style=\"width: 28%; padding: 11px 10px; border-bottom: 1px dashed #555;\"\u003e32 mm\u003c\/td\u003e\n\u003cth style=\"width: 22%; background: #f0f0f0; padding: 11px 10px; text-align: left; border-bottom: 1px dashed #555;\"\u003eL1 ± 2\u003c\/th\u003e\n\u003ctd style=\"width: 28%; padding: 11px 10px; border-bottom: 1px dashed #555;\"\u003e100 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 22%; background: #f0f0f0; padding: 11px 10px; text-align: left; border-bottom: 1px dashed #555;\"\u003eL2 ± 1\u003c\/th\u003e\n\u003ctd style=\"width: 28%; padding: 11px 10px; border-bottom: 1px dashed #555;\"\u003e18 mm\u003c\/td\u003e\n\u003cth style=\"width: 22%; background: #f0f0f0; padding: 11px 10px; text-align: left; border-bottom: 1px dashed #555;\"\u003eH1 ± 2\u003c\/th\u003e\n\u003ctd style=\"width: 28%; padding: 11px 10px; border-bottom: 1px dashed #555;\"\u003e140.4 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003c\/table\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\u003csection style=\"margin:0 0 24px;\"\u003e\u003ch2 style=\"font-family: Arial, Helvetica, sans-serif !important; font-weight: 700 !important; font-size: 26px; margin: 0 0 12px;\"\u003eWIRING INSTRUCTIONS\u003c\/h2\u003e\n\u003cdiv class=\"wiring-layout\"\u003e\n\u003cdiv class=\"wiring-visual\"\u003e\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/5%20wire%20auto%20return.png\" alt=\"5-wire auto-return wiring diagram\" style=\"border:0 !important;outline:0;box-shadow:none;display:block;width:100%;height:auto;margin-bottom:16px;\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"wiring-copy\"\u003e\n\u003cdiv class=\"wiring-title\"\u003e5 Wire (Auto Return + Indicator)\u003c\/div\u003e\n\u003cp\u003eFor this normally closed model, energizing the actuator opens the valve. If power is lost, the internal capacitor returns it to the fully closed position. Signal wires report the open and closed positions. Use the supplied wiring diagram to identify terminals, confirm the AC 110V-230V supply, and disconnect power before wiring.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"margin:0;\"\u003e\u003ch2 style=\"font-family: Arial, Helvetica, sans-serif !important; font-weight: 700 !important; font-size: 26px; margin: 0 0 12px;\"\u003eMANUAL DOWNLOAD\u003c\/h2\u003e\n\u003cp style=\"margin:0;\"\u003e\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/Manual-JFMSV40081.pdf\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"color:#000;text-decoration:underline;\"\u003eDownload the User Manual\u003c\/a\u003e\u003c\/p\u003e\u003c\/section\u003e\n\n\u003c\/div\u003e","brand":"U.S. Solid","offers":[{"title":"Default Title","offer_id":50721722204415,"sku":"JFMSV55012","price":263.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/jfmsv55012-1.jpg?v=1792486648"},{"product_id":"1-1-2-304-stainless-steel-motorized-ball-valve-3-piece-5-wire-auto-return-normally-closed-110-230-v-ac-ip67-standard-port-manual-override","title":"1-1\/2\" 304 Stainless Steel Motorized Ball Valve, 3-Piece, 5-Wire Auto Return, Normally Closed, 110-230 V AC, IP67, Standard Port, Manual Override","description":"\u003cdiv class=\"product-description\" style=\"font-family: Arial, Helvetica, sans-serif; color: #000; line-height: 1.6; width: 100%;\"\u003e\n\u003cstyle\u003e    .product-description, .product-description * { box-sizing: border-box; }\n    .product-description { width: 100% !important; max-width: 100% !important; overflow-x: hidden !important; }\n    .product-description img { max-width: 100% !important; }\n    .product-description table { width: 100% !important; max-width: 100% !important; min-width: 0 !important; table-layout: fixed !important; border-collapse: collapse; }\n    .product-description th, .product-description td { overflow-wrap: anywhere; word-break: break-word; }\n    .product-description .wiring-layout { width: 100%; max-width: 100%; }\n    @media screen and (max-width: 700px) {\n      .product-description th, .product-description td { padding: 6px !important; font-size: 12px !important; }\n      .product-description .wiring-layout { display: block; }\n      .product-description .wiring-visual { width: 100%; }\n    }\n    .wiring-layout { display: flex; align-items: stretch; gap: 24px; width: 100%; }\n    .wiring-visual { flex: 0 0 48%; aspect-ratio: 1 \/ 1; display: flex; align-items: center; justify-content: center; overflow: hidden; }\n    .wiring-visual img { display: block; width: 100% !important; height: 100% !important; object-fit: contain; margin: 0 !important; border: 0 !important; outline: 0; box-shadow: none; }\n    .wiring-copy { flex: 1 1 0; min-width: 0; display: block; padding: 28px; }\n    .wiring-copy p { margin: 100px 0 0; font-size: 18px; line-height: 1.8; }\n    .wiring-title { width: 100%; margin: 0 0 20px; padding: 14px 20px; background: #7abd1c; border: 1px solid #4a4a4a; border-radius: 10px; color: #fff; font-size: 32px; line-height: 1.25; font-weight: 700; font-style: italic; text-align: center; }\n    @media screen and (max-width: 768px) {\n      .wiring-layout { display: block; }\n      .wiring-visual { width: 100%; margin-bottom: 16px; }\n      .wiring-copy { display: block; padding: 20px; border: 0; }\n      .wiring-copy p { margin-top: 20px; font-size: 16px; line-height: 1.7; }\n      .wiring-title { font-size: 24px; padding: 12px 14px; }\n    }\n  \u003c\/style\u003e\n\n  \u003csection style=\"margin:0 0 24px;\"\u003e\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage-3piece.jpg\" alt='U.S. Solid 1-1\/2\" 304 Stainless Steel Motorized Ball Valve, 3-Piece, 5-Wire Auto Return, Normally Closed, 12-24 V DC \/ 24 V AC, IP67, Standard Port, Manual Override' style=\"border:0 !important;outline:0;box-shadow:none;display:block;width:100%;height:auto;\"\u003e\u003c\/section\u003e\u003csection style=\"margin:0 0 24px;\"\u003e\u003ch2 style=\"font-family: Arial, Helvetica, sans-serif !important; font-weight: 700 !important; font-size: 26px; margin: 0 0 12px;\"\u003eINTRODUCTION\u003c\/h2\u003e\n\u003cp style=\"margin:0 0 12px;\"\u003eThe U.S. Solid 1-1\/2 in motorized ball valve has a 304 stainless steel 3-piece body that is corrosion-resistant and designed for reliable fluid control applications. The bolted body unbolts into three pieces so the center ball and PTFE seats can be cleaned or reseated in line without cutting the pipe. It uses a 5-wire auto return, normally closed design: energize to open, and on power loss an internal capacitor drives the valve back to the fully closed position for safe shutoff, while the signal wires report open or closed status to your PLC, controller, or panel. A top indicator shows valve position at a glance, and a manual override with the included hex key works the valve by hand during a power outage. The standard-port bore handles up to 1.0 MPa (145 psi) for water and air lines, filtration, dosing, and other automated fluid control systems.\u003c\/p\u003e\u003c\/section\u003e\u003csection style=\"margin:0 0 24px;\"\u003e\u003ch2 style=\"font-family: Arial, Helvetica, sans-serif !important; font-weight: 700 !important; font-size: 26px; margin: 0 0 12px;\"\u003eFEATURES\u003c\/h2\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/features-3%20pieces-AC110-230V.jpg\" alt=\"JFMSV55013 product features\" style=\"border:0 !important;outline:0;box-shadow:none;display:block;width:100%;height:auto;margin-bottom:16px;\"\u003e\u003c\/section\u003e\u003csection style=\"margin:0 0 24px;\"\u003e\u003ch2 style=\"font-family: Arial, Helvetica, sans-serif !important; font-weight: 700 !important; font-size: 26px; margin: 0 0 12px;\"\u003eAPPLICATIONS\u003c\/h2\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application-3%20pieces.jpg\" alt=\"Typical applications for JFMSV55013\" style=\"border:0 !important;outline:0;box-shadow:none;display:block;width:100%;height:auto;margin-bottom:12px;\"\u003e\u003cp style=\"margin:0;\"\u003eSuitable for compatible water and air lines, filtration, process-water systems, dosing, HVAC, irrigation, and industrial fluid control. Confirm media compatibility and the rated pressure and temperature before installation.\u003c\/p\u003e\u003c\/section\u003e\u003csection style=\"margin:0 0 24px;\"\u003e\u003ch2 style=\"font-family: Arial, Helvetica, sans-serif !important; font-weight: 700 !important; font-size: 26px; margin: 0 0 12px;\"\u003eSPECIFICATIONS\u003c\/h2\u003e\n\u003cdiv style=\"width:100%;max-width:100%;overflow:hidden;\"\u003e\u003ctable style=\"width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;\"\u003e\n\u003ctr\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003eUSS-MSV55013\u003c\/td\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003eU.S. Solid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003eValve Material\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003e304 Stainless Steel\u003c\/td\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003eBall Seat\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003ePTFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003eBody\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003e3-Piece bolted\u003c\/td\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003ePort Size\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003e1-1\/2 in NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003eOrifice Size\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003e38 mm\u003c\/td\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003eOpen\/Close Time\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003e15 s or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003eWorking Voltage\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003eAC 110-230V\u003c\/td\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003eMax Torque\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003e50 Nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003eMax Working Pressure\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003e1.0 MPa (145 psi)\u003c\/td\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003eMedia Temperature\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003e2°C to 90°C (36°F to 194°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003eAmbient Temperature\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003e-15°C to 50°C (5°F to 122°F)\u003c\/td\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003eService Life\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003e30,000 cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003eDefault State\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003eNormally Closed\u003c\/td\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003eWiring Type\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003e5-Wire Auto Return + Indicator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003eEnclosure Rating\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003eIP67\u003c\/td\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003eBore Type\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003eStandard Port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"margin: 0 0 24px;\"\u003e\n    \u003ch2 style=\"font-family: Arial, Helvetica, sans-serif !important; font-weight: 700 !important; font-size: 26px; margin: 0 0 12px;\"\u003eDIMENSIONS\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/3-piece%20size.png\" alt=\"JFMSV55013 product dimensions\" style=\"border: 0 !important; outline: 0; box-shadow: none; display: block; width: 100%; height: auto; margin-bottom: 16px;\"\u003e\n    \u003cp style=\"margin: 0 0 12px;\"\u003eThe following dimensions apply to model JFMSV55013. All dimensions are in mm unless otherwise specified.\u003c\/p\u003e\n    \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n      \u003ctable style=\"width: 100%; min-width: 760px; border-collapse: collapse; table-layout: fixed; font-size: 16px;\"\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 22%; background: #f0f0f0; padding: 11px 10px; text-align: left; border-bottom: 1px dashed #555;\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"width: 28%; padding: 11px 10px; border-bottom: 1px dashed #555;\"\u003eJFMSV55013\u003c\/td\u003e\n\u003cth style=\"width: 22%; background: #f0f0f0; padding: 11px 10px; text-align: left; border-bottom: 1px dashed #555;\"\u003eSize\u003c\/th\u003e\n\u003ctd style=\"width: 28%; padding: 11px 10px; border-bottom: 1px dashed #555;\"\u003e1-1\/2\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 22%; background: #f0f0f0; padding: 11px 10px; text-align: left; border-bottom: 1px dashed #555;\"\u003eA\u003c\/th\u003e\n\u003ctd style=\"width: 28%; padding: 11px 10px; border-bottom: 1px dashed #555;\"\u003e126.4 mm\u003c\/td\u003e\n\u003cth style=\"width: 22%; background: #f0f0f0; padding: 11px 10px; text-align: left; border-bottom: 1px dashed #555;\"\u003eB\u003c\/th\u003e\n\u003ctd style=\"width: 28%; padding: 11px 10px; border-bottom: 1px dashed #555;\"\u003e105.8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 22%; background: #f0f0f0; padding: 11px 10px; text-align: left; border-bottom: 1px dashed #555;\"\u003eC\u003c\/th\u003e\n\u003ctd style=\"width: 28%; padding: 11px 10px; border-bottom: 1px dashed #555;\"\u003e88.8 mm\u003c\/td\u003e\n\u003cth style=\"width: 22%; background: #f0f0f0; padding: 11px 10px; text-align: left; border-bottom: 1px dashed #555;\"\u003eD1 ± 0.5\u003c\/th\u003e\n\u003ctd style=\"width: 28%; padding: 11px 10px; border-bottom: 1px dashed #555;\"\u003e1-1\/2\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 22%; background: #f0f0f0; padding: 11px 10px; text-align: left; border-bottom: 1px dashed #555;\"\u003ed1 ± 0.5\u003c\/th\u003e\n\u003ctd style=\"width: 28%; padding: 11px 10px; border-bottom: 1px dashed #555;\"\u003e38 mm\u003c\/td\u003e\n\u003cth style=\"width: 22%; background: #f0f0f0; padding: 11px 10px; text-align: left; border-bottom: 1px dashed #555;\"\u003eL1 ± 2\u003c\/th\u003e\n\u003ctd style=\"width: 28%; padding: 11px 10px; border-bottom: 1px dashed #555;\"\u003e109 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 22%; background: #f0f0f0; padding: 11px 10px; text-align: left; border-bottom: 1px dashed #555;\"\u003eL2 ± 1\u003c\/th\u003e\n\u003ctd style=\"width: 28%; padding: 11px 10px; border-bottom: 1px dashed #555;\"\u003e22 mm\u003c\/td\u003e\n\u003cth style=\"width: 22%; background: #f0f0f0; padding: 11px 10px; text-align: left; border-bottom: 1px dashed #555;\"\u003eH1 ± 2\u003c\/th\u003e\n\u003ctd style=\"width: 28%; padding: 11px 10px; border-bottom: 1px dashed #555;\"\u003e160.8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003c\/table\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\u003csection style=\"margin:0 0 24px;\"\u003e\u003ch2 style=\"font-family: Arial, Helvetica, sans-serif !important; font-weight: 700 !important; font-size: 26px; margin: 0 0 12px;\"\u003eWIRING INSTRUCTIONS\u003c\/h2\u003e\n\u003cdiv class=\"wiring-layout\"\u003e\n\u003cdiv class=\"wiring-visual\"\u003e\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/5%20wire%20auto%20return.png\" alt=\"5-wire auto-return wiring diagram\" style=\"border:0 !important;outline:0;box-shadow:none;display:block;width:100%;height:auto;margin-bottom:16px;\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"wiring-copy\"\u003e\n\u003cdiv class=\"wiring-title\"\u003e5 Wire (Auto Return + Indicator)\u003c\/div\u003e\n\u003cp\u003eFor this normally closed model, energizing the actuator opens the valve. If power is lost, the internal capacitor returns it to the fully closed position. Signal wires report the open and closed positions. Use the supplied wiring diagram to identify terminals, confirm the AC 110V-230V supply, and disconnect power before wiring.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"margin:0;\"\u003e\u003ch2 style=\"font-family: Arial, Helvetica, sans-serif !important; font-weight: 700 !important; font-size: 26px; margin: 0 0 12px;\"\u003eMANUAL DOWNLOAD\u003c\/h2\u003e\n\u003cp style=\"margin:0;\"\u003e\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/Manual-JFMSV40081.pdf\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"color:#000;text-decoration:underline;\"\u003eDownload the User Manual\u003c\/a\u003e\u003c\/p\u003e\u003c\/section\u003e\n\n\u003c\/div\u003e","brand":"U.S. Solid","offers":[{"title":"Default Title","offer_id":50721722466559,"sku":"JFMSV55013","price":365.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/jfmsv55013-1.jpg?v=1792486651"},{"product_id":"2-304-stainless-steel-motorized-ball-valve-3-piece-5-wire-auto-return-normally-closed-110-230-v-ac-ip67-standard-port-manual-override","title":"2\" 304 Stainless Steel Motorized Ball Valve, 3-Piece, 5-Wire Auto Return, Normally Closed, 110-230 V AC, IP67, Standard Port, Manual Override","description":"\u003cdiv class=\"product-description\" style=\"font-family: Arial, Helvetica, sans-serif; color: #000; line-height: 1.6; width: 100%;\"\u003e\n\u003cstyle\u003e    .product-description, .product-description * { box-sizing: border-box; }\n    .product-description { width: 100% !important; max-width: 100% !important; overflow-x: hidden !important; }\n    .product-description img { max-width: 100% !important; }\n    .product-description table { width: 100% !important; max-width: 100% !important; min-width: 0 !important; table-layout: fixed !important; border-collapse: collapse; }\n    .product-description th, .product-description td { overflow-wrap: anywhere; word-break: break-word; }\n    .product-description .wiring-layout { width: 100%; max-width: 100%; }\n    @media screen and (max-width: 700px) {\n      .product-description th, .product-description td { padding: 6px !important; font-size: 12px !important; }\n      .product-description .wiring-layout { display: block; }\n      .product-description .wiring-visual { width: 100%; }\n    }\n    .wiring-layout { display: flex; align-items: stretch; gap: 24px; width: 100%; }\n    .wiring-visual { flex: 0 0 48%; aspect-ratio: 1 \/ 1; display: flex; align-items: center; justify-content: center; overflow: hidden; }\n    .wiring-visual img { display: block; width: 100% !important; height: 100% !important; object-fit: contain; margin: 0 !important; border: 0 !important; outline: 0; box-shadow: none; }\n    .wiring-copy { flex: 1 1 0; min-width: 0; display: block; padding: 28px; }\n    .wiring-copy p { margin: 100px 0 0; font-size: 18px; line-height: 1.8; }\n    .wiring-title { width: 100%; margin: 0 0 20px; padding: 14px 20px; background: #7abd1c; border: 1px solid #4a4a4a; border-radius: 10px; color: #fff; font-size: 32px; line-height: 1.25; font-weight: 700; font-style: italic; text-align: center; }\n    @media screen and (max-width: 768px) {\n      .wiring-layout { display: block; }\n      .wiring-visual { width: 100%; margin-bottom: 16px; }\n      .wiring-copy { display: block; padding: 20px; border: 0; }\n      .wiring-copy p { margin-top: 20px; font-size: 16px; line-height: 1.7; }\n      .wiring-title { font-size: 24px; padding: 12px 14px; }\n    }\n  \u003c\/style\u003e\n\n  \u003csection style=\"margin:0 0 24px;\"\u003e\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage-3piece.jpg\" alt='U.S. Solid 2\" 304 Stainless Steel Motorized Ball Valve, 3-Piece, 5-Wire Auto Return, Normally Closed, 12-24 V DC \/ 24 V AC, IP67, Standard Port, Manual Override' style=\"border:0 !important;outline:0;box-shadow:none;display:block;width:100%;height:auto;\"\u003e\u003c\/section\u003e\u003csection style=\"margin:0 0 24px;\"\u003e\u003ch2 style=\"font-family: Arial, Helvetica, sans-serif !important; font-weight: 700 !important; font-size: 26px; margin: 0 0 12px;\"\u003eINTRODUCTION\u003c\/h2\u003e\n\u003cp style=\"margin:0 0 12px;\"\u003eThe U.S. Solid 2 in motorized ball valve has a 304 stainless steel 3-piece body that is corrosion-resistant and designed for reliable fluid control applications. The bolted body unbolts into three pieces so the center ball and PTFE seats can be cleaned or reseated in line without cutting the pipe. It uses a 5-wire auto return, normally closed design: energize to open, and on power loss an internal capacitor drives the valve back to the fully closed position for safe shutoff, while the signal wires report open or closed status to your PLC, controller, or panel. A top indicator shows valve position at a glance, and a manual override with the included hex key works the valve by hand during a power outage. The standard-port bore handles up to 1.0 MPa (145 psi) for water and air lines, filtration, dosing, and other automated fluid control systems.\u003c\/p\u003e\u003c\/section\u003e\u003csection style=\"margin:0 0 24px;\"\u003e\u003ch2 style=\"font-family: Arial, Helvetica, sans-serif !important; font-weight: 700 !important; font-size: 26px; margin: 0 0 12px;\"\u003eFEATURES\u003c\/h2\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/features-3%20pieces-AC110-230V.jpg\" alt=\"JFMSV55014 product features\" style=\"border:0 !important;outline:0;box-shadow:none;display:block;width:100%;height:auto;margin-bottom:16px;\"\u003e\u003c\/section\u003e\u003csection style=\"margin:0 0 24px;\"\u003e\u003ch2 style=\"font-family: Arial, Helvetica, sans-serif !important; font-weight: 700 !important; font-size: 26px; margin: 0 0 12px;\"\u003eAPPLICATIONS\u003c\/h2\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application-3%20pieces.jpg\" alt=\"Typical applications for JFMSV55014\" style=\"border:0 !important;outline:0;box-shadow:none;display:block;width:100%;height:auto;margin-bottom:12px;\"\u003e\u003cp style=\"margin:0;\"\u003eSuitable for compatible water and air lines, filtration, process-water systems, dosing, HVAC, irrigation, and industrial fluid control. Confirm media compatibility and the rated pressure and temperature before installation.\u003c\/p\u003e\u003c\/section\u003e\u003csection style=\"margin:0 0 24px;\"\u003e\u003ch2 style=\"font-family: Arial, Helvetica, sans-serif !important; font-weight: 700 !important; font-size: 26px; margin: 0 0 12px;\"\u003eSPECIFICATIONS\u003c\/h2\u003e\n\u003cdiv style=\"width:100%;max-width:100%;overflow:hidden;\"\u003e\u003ctable style=\"width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;\"\u003e\n\u003ctr\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003eUSS-MSV55014\u003c\/td\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003eU.S. Solid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003eValve Material\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003e304 Stainless Steel\u003c\/td\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003eBall Seat\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003ePTFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003eBody\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003e3-Piece bolted\u003c\/td\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003ePort Size\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003e2 in NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003eOrifice Size\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003e49 mm\u003c\/td\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003eOpen\/Close Time\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003e15 s or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003eWorking Voltage\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003eAC 110-230V\u003c\/td\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003eMax Torque\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003e50 Nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003eMax Working Pressure\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003e1.0 MPa (145 psi)\u003c\/td\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003eMedia Temperature\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003e2°C to 90°C (36°F to 194°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003eAmbient Temperature\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003e-15°C to 50°C (5°F to 122°F)\u003c\/td\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003eService Life\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003e30,000 cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003eDefault State\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003eNormally Closed\u003c\/td\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003eWiring Type\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003e5-Wire Auto Return + Indicator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003eEnclosure Rating\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003eIP67\u003c\/td\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003eBore Type\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003eStandard Port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"margin: 0 0 24px;\"\u003e\n    \u003ch2 style=\"font-family: Arial, Helvetica, sans-serif !important; font-weight: 700 !important; font-size: 26px; margin: 0 0 12px;\"\u003eDIMENSIONS\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/3-piece%20size.png\" alt=\"JFMSV55014 product dimensions\" style=\"border: 0 !important; outline: 0; box-shadow: none; display: block; width: 100%; height: auto; margin-bottom: 16px;\"\u003e\n    \u003cp style=\"margin: 0 0 12px;\"\u003eThe following dimensions apply to model JFMSV55014. All dimensions are in mm unless otherwise specified.\u003c\/p\u003e\n    \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n      \u003ctable style=\"width: 100%; min-width: 760px; border-collapse: collapse; table-layout: fixed; font-size: 16px;\"\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 22%; background: #f0f0f0; padding: 11px 10px; text-align: left; border-bottom: 1px dashed #555;\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"width: 28%; padding: 11px 10px; border-bottom: 1px dashed #555;\"\u003eJFMSV55014\u003c\/td\u003e\n\u003cth style=\"width: 22%; background: #f0f0f0; padding: 11px 10px; text-align: left; border-bottom: 1px dashed #555;\"\u003eSize\u003c\/th\u003e\n\u003ctd style=\"width: 28%; padding: 11px 10px; border-bottom: 1px dashed #555;\"\u003e2\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 22%; background: #f0f0f0; padding: 11px 10px; text-align: left; border-bottom: 1px dashed #555;\"\u003eA\u003c\/th\u003e\n\u003ctd style=\"width: 28%; padding: 11px 10px; border-bottom: 1px dashed #555;\"\u003e126.4 mm\u003c\/td\u003e\n\u003cth style=\"width: 22%; background: #f0f0f0; padding: 11px 10px; text-align: left; border-bottom: 1px dashed #555;\"\u003eB\u003c\/th\u003e\n\u003ctd style=\"width: 28%; padding: 11px 10px; border-bottom: 1px dashed #555;\"\u003e105.8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 22%; background: #f0f0f0; padding: 11px 10px; text-align: left; border-bottom: 1px dashed #555;\"\u003eC\u003c\/th\u003e\n\u003ctd style=\"width: 28%; padding: 11px 10px; border-bottom: 1px dashed #555;\"\u003e88.8 mm\u003c\/td\u003e\n\u003cth style=\"width: 22%; background: #f0f0f0; padding: 11px 10px; text-align: left; border-bottom: 1px dashed #555;\"\u003eD1 ± 0.5\u003c\/th\u003e\n\u003ctd style=\"width: 28%; padding: 11px 10px; border-bottom: 1px dashed #555;\"\u003e2\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 22%; background: #f0f0f0; padding: 11px 10px; text-align: left; border-bottom: 1px dashed #555;\"\u003ed1 ± 0.5\u003c\/th\u003e\n\u003ctd style=\"width: 28%; padding: 11px 10px; border-bottom: 1px dashed #555;\"\u003e49 mm\u003c\/td\u003e\n\u003cth style=\"width: 22%; background: #f0f0f0; padding: 11px 10px; text-align: left; border-bottom: 1px dashed #555;\"\u003eL1 ± 2\u003c\/th\u003e\n\u003ctd style=\"width: 28%; padding: 11px 10px; border-bottom: 1px dashed #555;\"\u003e134 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 22%; background: #f0f0f0; padding: 11px 10px; text-align: left; border-bottom: 1px dashed #555;\"\u003eL2 ± 1\u003c\/th\u003e\n\u003ctd style=\"width: 28%; padding: 11px 10px; border-bottom: 1px dashed #555;\"\u003e27 mm\u003c\/td\u003e\n\u003cth style=\"width: 22%; background: #f0f0f0; padding: 11px 10px; text-align: left; border-bottom: 1px dashed #555;\"\u003eH1 ± 2\u003c\/th\u003e\n\u003ctd style=\"width: 28%; padding: 11px 10px; border-bottom: 1px dashed #555;\"\u003e167.8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003c\/table\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\u003csection style=\"margin:0 0 24px;\"\u003e\u003ch2 style=\"font-family: Arial, Helvetica, sans-serif !important; font-weight: 700 !important; font-size: 26px; margin: 0 0 12px;\"\u003eWIRING INSTRUCTIONS\u003c\/h2\u003e\n\u003cdiv class=\"wiring-layout\"\u003e\n\u003cdiv class=\"wiring-visual\"\u003e\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/5%20wire%20auto%20return.png\" alt=\"5-wire auto-return wiring diagram\" style=\"border:0 !important;outline:0;box-shadow:none;display:block;width:100%;height:auto;margin-bottom:16px;\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"wiring-copy\"\u003e\n\u003cdiv class=\"wiring-title\"\u003e5 Wire (Auto Return + Indicator)\u003c\/div\u003e\n\u003cp\u003eFor this normally closed model, energizing the actuator opens the valve. If power is lost, the internal capacitor returns it to the fully closed position. Signal wires report the open and closed positions. Use the supplied wiring diagram to identify terminals, confirm the AC 110V-230V supply, and disconnect power before wiring.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"margin:0;\"\u003e\u003ch2 style=\"font-family: Arial, Helvetica, sans-serif !important; font-weight: 700 !important; font-size: 26px; margin: 0 0 12px;\"\u003eMANUAL DOWNLOAD\u003c\/h2\u003e\n\u003cp style=\"margin:0;\"\u003e\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/Manual-JFMSV40081.pdf\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"color:#000;text-decoration:underline;\"\u003eDownload the User Manual\u003c\/a\u003e\u003c\/p\u003e\u003c\/section\u003e\n\n\u003c\/div\u003e","brand":"U.S. Solid","offers":[{"title":"Default Title","offer_id":50721723023615,"sku":"JFMSV55014","price":415.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/jfmsv55014-1.jpg?v=1792486651"},{"product_id":"2-1-2-304-stainless-steel-motorized-ball-valve-3-piece-5-wire-auto-return-normally-closed-110-230-v-ac-ip67-standard-port-manual-override","title":"2-1\/2\" 304 Stainless Steel Motorized Ball Valve, 3-Piece, 5-Wire Auto Return, Normally Closed, 110-230 V AC, IP67, Standard Port, Manual Override","description":"\u003cdiv class=\"product-description\" style=\"font-family: Arial, Helvetica, sans-serif; color: #000; line-height: 1.6; width: 100%;\"\u003e\n\u003cstyle\u003e    .product-description, .product-description * { box-sizing: border-box; }\n    .product-description { width: 100% !important; max-width: 100% !important; overflow-x: hidden !important; }\n    .product-description img { max-width: 100% !important; }\n    .product-description table { width: 100% !important; max-width: 100% !important; min-width: 0 !important; table-layout: fixed !important; border-collapse: collapse; }\n    .product-description th, .product-description td { overflow-wrap: anywhere; word-break: break-word; }\n    .product-description .wiring-layout { width: 100%; max-width: 100%; }\n    @media screen and (max-width: 700px) {\n      .product-description th, .product-description td { padding: 6px !important; font-size: 12px !important; }\n      .product-description .wiring-layout { display: block; }\n      .product-description .wiring-visual { width: 100%; }\n    }\n    .wiring-layout { display: flex; align-items: stretch; gap: 24px; width: 100%; }\n    .wiring-visual { flex: 0 0 48%; aspect-ratio: 1 \/ 1; display: flex; align-items: center; justify-content: center; overflow: hidden; }\n    .wiring-visual img { display: block; width: 100% !important; height: 100% !important; object-fit: contain; margin: 0 !important; border: 0 !important; outline: 0; box-shadow: none; }\n    .wiring-copy { flex: 1 1 0; min-width: 0; display: block; padding: 28px; }\n    .wiring-copy p { margin: 100px 0 0; font-size: 18px; line-height: 1.8; }\n    .wiring-title { width: 100%; margin: 0 0 20px; padding: 14px 20px; background: #7abd1c; border: 1px solid #4a4a4a; border-radius: 10px; color: #fff; font-size: 32px; line-height: 1.25; font-weight: 700; font-style: italic; text-align: center; }\n    @media screen and (max-width: 768px) {\n      .wiring-layout { display: block; }\n      .wiring-visual { width: 100%; margin-bottom: 16px; }\n      .wiring-copy { display: block; padding: 20px; border: 0; }\n      .wiring-copy p { margin-top: 20px; font-size: 16px; line-height: 1.7; }\n      .wiring-title { font-size: 24px; padding: 12px 14px; }\n    }\n  \u003c\/style\u003e\n\n  \u003csection style=\"margin:0 0 24px;\"\u003e\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage-3piece.jpg\" alt='U.S. Solid 2-1\/2\" 304 Stainless Steel Motorized Ball Valve, 3-Piece, 5-Wire Auto Return, Normally Closed, 12-24 V DC \/ 24 V AC, IP67, Standard Port, Manual Override' style=\"border:0 !important;outline:0;box-shadow:none;display:block;width:100%;height:auto;\"\u003e\u003c\/section\u003e\u003csection style=\"margin:0 0 24px;\"\u003e\u003ch2 style=\"font-family: Arial, Helvetica, sans-serif !important; font-weight: 700 !important; font-size: 26px; margin: 0 0 12px;\"\u003eINTRODUCTION\u003c\/h2\u003e\n\u003cp style=\"margin:0 0 12px;\"\u003eThe U.S. Solid 2-1\/2 in motorized ball valve has a 304 stainless steel 3-piece body that is corrosion-resistant and designed for reliable fluid control applications. The bolted body unbolts into three pieces so the center ball and PTFE seats can be cleaned or reseated in line without cutting the pipe. It uses a 5-wire auto return, normally closed design: energize to open, and on power loss an internal capacitor drives the valve back to the fully closed position for safe shutoff, while the signal wires report open or closed status to your PLC, controller, or panel. A top indicator shows valve position at a glance, and a manual override with the included hex key works the valve by hand during a power outage. The standard-port bore handles up to 1.0 MPa (145 psi) for water and air lines, filtration, dosing, and other automated fluid control systems.\u003c\/p\u003e\u003c\/section\u003e\u003csection style=\"margin:0 0 24px;\"\u003e\u003ch2 style=\"font-family: Arial, Helvetica, sans-serif !important; font-weight: 700 !important; font-size: 26px; margin: 0 0 12px;\"\u003eFEATURES\u003c\/h2\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/features-3%20pieces-AC110-230V.jpg\" alt=\"JFMSV55015 product features\" style=\"border:0 !important;outline:0;box-shadow:none;display:block;width:100%;height:auto;margin-bottom:16px;\"\u003e\u003c\/section\u003e\u003csection style=\"margin:0 0 24px;\"\u003e\u003ch2 style=\"font-family: Arial, Helvetica, sans-serif !important; font-weight: 700 !important; font-size: 26px; margin: 0 0 12px;\"\u003eAPPLICATIONS\u003c\/h2\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application-3%20pieces.jpg\" alt=\"Typical applications for JFMSV55015\" style=\"border:0 !important;outline:0;box-shadow:none;display:block;width:100%;height:auto;margin-bottom:12px;\"\u003e\u003cp style=\"margin:0;\"\u003eSuitable for compatible water and air lines, filtration, process-water systems, dosing, HVAC, irrigation, and industrial fluid control. Confirm media compatibility and the rated pressure and temperature before installation.\u003c\/p\u003e\u003c\/section\u003e\u003csection style=\"margin:0 0 24px;\"\u003e\u003ch2 style=\"font-family: Arial, Helvetica, sans-serif !important; font-weight: 700 !important; font-size: 26px; margin: 0 0 12px;\"\u003eSPECIFICATIONS\u003c\/h2\u003e\n\u003cdiv style=\"width:100%;max-width:100%;overflow:hidden;\"\u003e\u003ctable style=\"width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;\"\u003e\n\u003ctr\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003eUSS-MSV55015\u003c\/td\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003eU.S. Solid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003eValve Material\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003e304 Stainless Steel\u003c\/td\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003eBall Seat\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003ePTFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003eBody\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003e3-Piece bolted\u003c\/td\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003ePort Size\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003e2-1\/2 in NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003eOrifice Size\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003e65 mm\u003c\/td\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003eOpen\/Close Time\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003e15 s or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003eWorking Voltage\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003eAC 110-230V\u003c\/td\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003eMax Torque\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003e50 Nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003eMax Working Pressure\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003e1.0 MPa (145 psi)\u003c\/td\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003eMedia Temperature\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003e2°C to 90°C (36°F to 194°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003eAmbient Temperature\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003e-15°C to 50°C (5°F to 122°F)\u003c\/td\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003eService Life\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003e30,000 cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003eDefault State\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003eNormally Closed\u003c\/td\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003eWiring Type\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003e5-Wire Auto Return + Indicator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003eEnclosure Rating\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003eIP67\u003c\/td\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003eBore Type\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003eStandard Port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"margin: 0 0 24px;\"\u003e\n    \u003ch2 style=\"font-family: Arial, Helvetica, sans-serif !important; font-weight: 700 !important; font-size: 26px; margin: 0 0 12px;\"\u003eDIMENSIONS\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/3-piece%20size.png\" alt=\"JFMSV55015 product dimensions\" style=\"border: 0 !important; outline: 0; box-shadow: none; display: block; width: 100%; height: auto; margin-bottom: 16px;\"\u003e\n    \u003cp style=\"margin: 0 0 12px;\"\u003eThe following dimensions apply to model JFMSV55015. All dimensions are in mm unless otherwise specified.\u003c\/p\u003e\n    \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n      \u003ctable style=\"width: 100%; min-width: 760px; border-collapse: collapse; table-layout: fixed; font-size: 16px;\"\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 22%; background: #f0f0f0; padding: 11px 10px; text-align: left; border-bottom: 1px dashed #555;\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"width: 28%; padding: 11px 10px; border-bottom: 1px dashed #555;\"\u003eJFMSV55015\u003c\/td\u003e\n\u003cth style=\"width: 22%; background: #f0f0f0; padding: 11px 10px; text-align: left; border-bottom: 1px dashed #555;\"\u003eSize\u003c\/th\u003e\n\u003ctd style=\"width: 28%; padding: 11px 10px; border-bottom: 1px dashed #555;\"\u003e2-1\/2\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 22%; background: #f0f0f0; padding: 11px 10px; text-align: left; border-bottom: 1px dashed #555;\"\u003eA\u003c\/th\u003e\n\u003ctd style=\"width: 28%; padding: 11px 10px; border-bottom: 1px dashed #555;\"\u003e126.4 mm\u003c\/td\u003e\n\u003cth style=\"width: 22%; background: #f0f0f0; padding: 11px 10px; text-align: left; border-bottom: 1px dashed #555;\"\u003eB\u003c\/th\u003e\n\u003ctd style=\"width: 28%; padding: 11px 10px; border-bottom: 1px dashed #555;\"\u003e105.8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 22%; background: #f0f0f0; padding: 11px 10px; text-align: left; border-bottom: 1px dashed #555;\"\u003eC\u003c\/th\u003e\n\u003ctd style=\"width: 28%; padding: 11px 10px; border-bottom: 1px dashed #555;\"\u003e88.8 mm\u003c\/td\u003e\n\u003cth style=\"width: 22%; background: #f0f0f0; padding: 11px 10px; text-align: left; border-bottom: 1px dashed #555;\"\u003eD1 ± 0.5\u003c\/th\u003e\n\u003ctd style=\"width: 28%; padding: 11px 10px; border-bottom: 1px dashed #555;\"\u003e2-1\/2\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 22%; background: #f0f0f0; padding: 11px 10px; text-align: left; border-bottom: 1px dashed #555;\"\u003ed1 ± 0.5\u003c\/th\u003e\n\u003ctd style=\"width: 28%; padding: 11px 10px; border-bottom: 1px dashed #555;\"\u003e65 mm\u003c\/td\u003e\n\u003cth style=\"width: 22%; background: #f0f0f0; padding: 11px 10px; text-align: left; border-bottom: 1px dashed #555;\"\u003eL1 ± 2\u003c\/th\u003e\n\u003ctd style=\"width: 28%; padding: 11px 10px; border-bottom: 1px dashed #555;\"\u003e165 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 22%; background: #f0f0f0; padding: 11px 10px; text-align: left; border-bottom: 1px dashed #555;\"\u003eL2 ± 1\u003c\/th\u003e\n\u003ctd style=\"width: 28%; padding: 11px 10px; border-bottom: 1px dashed #555;\"\u003e34 mm\u003c\/td\u003e\n\u003cth style=\"width: 22%; background: #f0f0f0; padding: 11px 10px; text-align: left; border-bottom: 1px dashed #555;\"\u003eH1 ± 2\u003c\/th\u003e\n\u003ctd style=\"width: 28%; padding: 11px 10px; border-bottom: 1px dashed #555;\"\u003e184.8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003c\/table\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\u003csection style=\"margin:0 0 24px;\"\u003e\u003ch2 style=\"font-family: Arial, Helvetica, sans-serif !important; font-weight: 700 !important; font-size: 26px; margin: 0 0 12px;\"\u003eWIRING INSTRUCTIONS\u003c\/h2\u003e\n\u003cdiv class=\"wiring-layout\"\u003e\n\u003cdiv class=\"wiring-visual\"\u003e\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/5%20wire%20auto%20return.png\" alt=\"5-wire auto-return wiring diagram\" style=\"border:0 !important;outline:0;box-shadow:none;display:block;width:100%;height:auto;margin-bottom:16px;\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"wiring-copy\"\u003e\n\u003cdiv class=\"wiring-title\"\u003e5 Wire (Auto Return + Indicator)\u003c\/div\u003e\n\u003cp\u003eFor this normally closed model, energizing the actuator opens the valve. If power is lost, the internal capacitor returns it to the fully closed position. Signal wires report the open and closed positions. Use the supplied wiring diagram to identify terminals, confirm the AC 110V-230V supply, and disconnect power before wiring.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"margin:0;\"\u003e\u003ch2 style=\"font-family: Arial, Helvetica, sans-serif !important; font-weight: 700 !important; font-size: 26px; margin: 0 0 12px;\"\u003eMANUAL DOWNLOAD\u003c\/h2\u003e\n\u003cp style=\"margin:0;\"\u003e\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/Manual-JFMSV40081.pdf\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"color:#000;text-decoration:underline;\"\u003eDownload the User Manual\u003c\/a\u003e\u003c\/p\u003e\u003c\/section\u003e\n\n\u003c\/div\u003e","brand":"U.S. Solid","offers":[{"title":"Default Title","offer_id":50721723252991,"sku":"JFMSV55015","price":545.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/jfmsv55015-1.jpg?v=1792486653"},{"product_id":"3-304-stainless-steel-motorized-ball-valve-3-piece-5-wire-auto-return-normally-closed-110-230-v-ac-ip67-standard-port-manual-override","title":"3\" 304 Stainless Steel Motorized Ball Valve, 3-Piece, 5-Wire Auto Return, Normally Closed, 110-230 V AC, IP67, Standard Port, Manual Override","description":"\u003cdiv class=\"product-description\" style=\"font-family: Arial, Helvetica, sans-serif; color: #000; line-height: 1.6; width: 100%;\"\u003e\n\u003cstyle\u003e    .product-description, .product-description * { box-sizing: border-box; }\n    .product-description { width: 100% !important; max-width: 100% !important; overflow-x: hidden !important; }\n    .product-description img { max-width: 100% !important; }\n    .product-description table { width: 100% !important; max-width: 100% !important; min-width: 0 !important; table-layout: fixed !important; border-collapse: collapse; }\n    .product-description th, .product-description td { overflow-wrap: anywhere; word-break: break-word; }\n    .product-description .wiring-layout { width: 100%; max-width: 100%; }\n    @media screen and (max-width: 700px) {\n      .product-description th, .product-description td { padding: 6px !important; font-size: 12px !important; }\n      .product-description .wiring-layout { display: block; }\n      .product-description .wiring-visual { width: 100%; }\n    }\n    .wiring-layout { display: flex; align-items: stretch; gap: 24px; width: 100%; }\n    .wiring-visual { flex: 0 0 48%; aspect-ratio: 1 \/ 1; display: flex; align-items: center; justify-content: center; overflow: hidden; }\n    .wiring-visual img { display: block; width: 100% !important; height: 100% !important; object-fit: contain; margin: 0 !important; border: 0 !important; outline: 0; box-shadow: none; }\n    .wiring-copy { flex: 1 1 0; min-width: 0; display: block; padding: 28px; }\n    .wiring-copy p { margin: 100px 0 0; font-size: 18px; line-height: 1.8; }\n    .wiring-title { width: 100%; margin: 0 0 20px; padding: 14px 20px; background: #7abd1c; border: 1px solid #4a4a4a; border-radius: 10px; color: #fff; font-size: 32px; line-height: 1.25; font-weight: 700; font-style: italic; text-align: center; }\n    @media screen and (max-width: 768px) {\n      .wiring-layout { display: block; }\n      .wiring-visual { width: 100%; margin-bottom: 16px; }\n      .wiring-copy { display: block; padding: 20px; border: 0; }\n      .wiring-copy p { margin-top: 20px; font-size: 16px; line-height: 1.7; }\n      .wiring-title { font-size: 24px; padding: 12px 14px; }\n    }\n  \u003c\/style\u003e\n\n  \u003csection style=\"margin:0 0 24px;\"\u003e\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage-3piece.jpg\" alt='U.S. Solid 3\" 304 Stainless Steel Motorized Ball Valve, 3-Piece, 5-Wire Auto Return, Normally Closed, 12-24 V DC \/ 24 V AC, IP67, Standard Port, Manual Override' style=\"border:0 !important;outline:0;box-shadow:none;display:block;width:100%;height:auto;\"\u003e\u003c\/section\u003e\u003csection style=\"margin:0 0 24px;\"\u003e\u003ch2 style=\"font-family: Arial, Helvetica, sans-serif !important; font-weight: 700 !important; font-size: 26px; margin: 0 0 12px;\"\u003eINTRODUCTION\u003c\/h2\u003e\n\u003cp style=\"margin:0 0 12px;\"\u003eThe U.S. Solid 3 in motorized ball valve has a 304 stainless steel 3-piece body that is corrosion-resistant and designed for reliable fluid control applications. The bolted body unbolts into three pieces so the center ball and PTFE seats can be cleaned or reseated in line without cutting the pipe. It uses a 5-wire auto return, normally closed design: energize to open, and on power loss an internal capacitor drives the valve back to the fully closed position for safe shutoff, while the signal wires report open or closed status to your PLC, controller, or panel. A top indicator shows valve position at a glance, and a manual override with the included hex key works the valve by hand during a power outage. The standard-port bore handles up to 1.0 MPa (145 psi) for water and air lines, filtration, dosing, and other automated fluid control systems.\u003c\/p\u003e\u003c\/section\u003e\u003csection style=\"margin:0 0 24px;\"\u003e\u003ch2 style=\"font-family: Arial, Helvetica, sans-serif !important; font-weight: 700 !important; font-size: 26px; margin: 0 0 12px;\"\u003eFEATURES\u003c\/h2\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/features-3%20pieces-AC110-230V.jpg\" alt=\"JFMSV55016 product features\" style=\"border:0 !important;outline:0;box-shadow:none;display:block;width:100%;height:auto;margin-bottom:16px;\"\u003e\u003c\/section\u003e\u003csection style=\"margin:0 0 24px;\"\u003e\u003ch2 style=\"font-family: Arial, Helvetica, sans-serif !important; font-weight: 700 !important; font-size: 26px; margin: 0 0 12px;\"\u003eAPPLICATIONS\u003c\/h2\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application-3%20pieces.jpg\" alt=\"Typical applications for JFMSV55016\" style=\"border:0 !important;outline:0;box-shadow:none;display:block;width:100%;height:auto;margin-bottom:12px;\"\u003e\u003cp style=\"margin:0;\"\u003eSuitable for compatible water and air lines, filtration, process-water systems, dosing, HVAC, irrigation, and industrial fluid control. Confirm media compatibility and the rated pressure and temperature before installation.\u003c\/p\u003e\u003c\/section\u003e\u003csection style=\"margin:0 0 24px;\"\u003e\u003ch2 style=\"font-family: Arial, Helvetica, sans-serif !important; font-weight: 700 !important; font-size: 26px; margin: 0 0 12px;\"\u003eSPECIFICATIONS\u003c\/h2\u003e\n\u003cdiv style=\"width:100%;max-width:100%;overflow:hidden;\"\u003e\u003ctable style=\"width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;\"\u003e\n\u003ctr\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003eUSS-MSV55016\u003c\/td\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003eU.S. Solid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003eValve Material\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003e304 Stainless Steel\u003c\/td\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003eBall Seat\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003ePTFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003eBody\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003e3-Piece bolted\u003c\/td\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003ePort Size\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003e3 in NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003eOrifice Size\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003e80 mm\u003c\/td\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003eOpen\/Close Time\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003e15 s or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003eWorking Voltage\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003eAC 110-230V\u003c\/td\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003eMax Torque\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003e50 Nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003eMax Working Pressure\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003e1.0 MPa (145 psi)\u003c\/td\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003eMedia Temperature\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003e2°C to 90°C (36°F to 194°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003eAmbient Temperature\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003e-15°C to 50°C (5°F to 122°F)\u003c\/td\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003eService Life\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003e30,000 cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003eDefault State\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003eNormally Closed\u003c\/td\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003eWiring Type\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003e5-Wire Auto Return + Indicator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003eEnclosure Rating\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003eIP67\u003c\/td\u003e\n\u003cth style=\"width:17%;padding:10px 12px;text-align:left;border:1px solid #d9e0e6;background:#f5f7f9;font-weight:700;\"\u003eBore Type\u003c\/th\u003e\n\u003ctd style=\"width:33%;padding:10px 12px;border:1px solid #d9e0e6;\"\u003eStandard Port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"margin: 0 0 24px;\"\u003e\n    \u003ch2 style=\"font-family: Arial, Helvetica, sans-serif !important; font-weight: 700 !important; font-size: 26px; margin: 0 0 12px;\"\u003eDIMENSIONS\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/3-piece%20size.png\" alt=\"JFMSV55016 product dimensions\" style=\"border: 0 !important; outline: 0; box-shadow: none; display: block; width: 100%; height: auto; margin-bottom: 16px;\"\u003e\n    \u003cp style=\"margin: 0 0 12px;\"\u003eThe following dimensions apply to model JFMSV55016. All dimensions are in mm unless otherwise specified.\u003c\/p\u003e\n    \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n      \u003ctable style=\"width: 100%; min-width: 760px; border-collapse: collapse; table-layout: fixed; font-size: 16px;\"\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 22%; background: #f0f0f0; padding: 11px 10px; text-align: left; border-bottom: 1px dashed #555;\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"width: 28%; padding: 11px 10px; border-bottom: 1px dashed #555;\"\u003eJFMSV55016\u003c\/td\u003e\n\u003cth style=\"width: 22%; background: #f0f0f0; padding: 11px 10px; text-align: left; border-bottom: 1px dashed #555;\"\u003eSize\u003c\/th\u003e\n\u003ctd style=\"width: 28%; padding: 11px 10px; border-bottom: 1px dashed #555;\"\u003e3\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 22%; background: #f0f0f0; padding: 11px 10px; text-align: left; border-bottom: 1px dashed #555;\"\u003eA\u003c\/th\u003e\n\u003ctd style=\"width: 28%; padding: 11px 10px; border-bottom: 1px dashed #555;\"\u003e126.4 mm\u003c\/td\u003e\n\u003cth style=\"width: 22%; background: #f0f0f0; padding: 11px 10px; text-align: left; border-bottom: 1px dashed #555;\"\u003eB\u003c\/th\u003e\n\u003ctd style=\"width: 28%; padding: 11px 10px; border-bottom: 1px dashed #555;\"\u003e105.8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 22%; background: #f0f0f0; padding: 11px 10px; text-align: left; border-bottom: 1px dashed #555;\"\u003eC\u003c\/th\u003e\n\u003ctd style=\"width: 28%; padding: 11px 10px; border-bottom: 1px dashed #555;\"\u003e88.8 mm\u003c\/td\u003e\n\u003cth style=\"width: 22%; background: #f0f0f0; padding: 11px 10px; text-align: left; border-bottom: 1px dashed #555;\"\u003eD1 ± 0.5\u003c\/th\u003e\n\u003ctd style=\"width: 28%; padding: 11px 10px; border-bottom: 1px dashed #555;\"\u003e3\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 22%; background: #f0f0f0; padding: 11px 10px; text-align: left; border-bottom: 1px dashed #555;\"\u003ed1 ± 0.5\u003c\/th\u003e\n\u003ctd style=\"width: 28%; padding: 11px 10px; border-bottom: 1px dashed #555;\"\u003e80 mm\u003c\/td\u003e\n\u003cth style=\"width: 22%; background: #f0f0f0; padding: 11px 10px; text-align: left; border-bottom: 1px dashed #555;\"\u003eL1 ± 2\u003c\/th\u003e\n\u003ctd style=\"width: 28%; padding: 11px 10px; border-bottom: 1px dashed #555;\"\u003e192.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 22%; background: #f0f0f0; padding: 11px 10px; text-align: left; border-bottom: 1px dashed #555;\"\u003eL2 ± 1\u003c\/th\u003e\n\u003ctd style=\"width: 28%; padding: 11px 10px; border-bottom: 1px dashed #555;\"\u003e38 mm\u003c\/td\u003e\n\u003cth style=\"width: 22%; background: #f0f0f0; padding: 11px 10px; text-align: left; border-bottom: 1px dashed #555;\"\u003eH1 ± 2\u003c\/th\u003e\n\u003ctd style=\"width: 28%; padding: 11px 10px; border-bottom: 1px dashed #555;\"\u003e197.8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003c\/table\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\u003csection style=\"margin:0 0 24px;\"\u003e\u003ch2 style=\"font-family: Arial, Helvetica, sans-serif !important; font-weight: 700 !important; font-size: 26px; margin: 0 0 12px;\"\u003eWIRING INSTRUCTIONS\u003c\/h2\u003e\n\u003cdiv class=\"wiring-layout\"\u003e\n\u003cdiv class=\"wiring-visual\"\u003e\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/5%20wire%20auto%20return.png\" alt=\"5-wire auto-return wiring diagram\" style=\"border:0 !important;outline:0;box-shadow:none;display:block;width:100%;height:auto;margin-bottom:16px;\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"wiring-copy\"\u003e\n\u003cdiv class=\"wiring-title\"\u003e5 Wire (Auto Return + Indicator)\u003c\/div\u003e\n\u003cp\u003eFor this normally closed model, energizing the actuator opens the valve. If power is lost, the internal capacitor returns it to the fully closed position. Signal wires report the open and closed positions. Use the supplied wiring diagram to identify terminals, confirm the AC 110V-230V supply, and disconnect power before wiring.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"margin:0;\"\u003e\u003ch2 style=\"font-family: Arial, Helvetica, sans-serif !important; font-weight: 700 !important; font-size: 26px; margin: 0 0 12px;\"\u003eMANUAL DOWNLOAD\u003c\/h2\u003e\n\u003cp style=\"margin:0;\"\u003e\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/Manual-JFMSV40081.pdf\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"color:#000;text-decoration:underline;\"\u003eDownload the User Manual\u003c\/a\u003e\u003c\/p\u003e\u003c\/section\u003e\n\n\u003c\/div\u003e","brand":"U.S. Solid","offers":[{"title":"Default Title","offer_id":50721723482367,"sku":"JFMSV55016","price":665.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/jfmsv55016-1.jpg?v=1792486653"},{"product_id":"1-1-4-upvc-motorized-ball-valve-double-union-110-230v-ac-with-us-plug-auto-return-normally-closed-ip67-full-port-npt-manual-override-position-indicator","title":"1-1\/4\" UPVC Motorized Ball Valve, 110-230V AC US Plug, Double Union, Full Port, Auto Return, Normally Closed","description":"\u003cmeta charset=\"utf-8\"\u003e\n\u003cmeta content=\"width=device-width, initial-scale=1.0\" name=\"viewport\"\u003e\n\u003cstyle\u003e\n.desktop-img { display: block; width: 100%; }\n.mobile-img { display: none; width: 100%; }\n\n.section-title,\n.section-title2,\n.section-title3,\n.section-title4 {\n    font-size: 22px;\n    line-height: 22px;\n    font-weight: bold;\n    margin: 15px 0 10px;\n    font-family: Arial;\n    color: black;\n}\n\n.title-center {\n    text-align: center;\n}\n\n.section-description {\n    font-size: 16px;\n    line-height: 26px;\n    margin: 5px 0;\n    font-family: Arial;\n    color: black;\n}\n\n.section-description2 {\n    font-size: 16px;\n    line-height: 26px;\n    margin: 0;\n    font-family: Arial;\n}\n\n.faq {\n    font-size: 16px;\n    line-height: 26px;\n    padding: 5px;\n    margin: 10px 0 5px;\n    font-family: Arial;\n    color: black;\n}\n\n.warning-title {\n    font-size: 22px;\n    text-align: left;\n    margin-top: 20px;\n    margin-bottom: 10px;\n    line-height: 26px;\n    color: black;\n    font-weight: bold;\n    font-family: Arial;\n  }\n\n  .flex-row {\n    display: flex;\n    gap: 20px;\n    margin: 20px 0;\n}\n\n.flex-item {\n    flex: 1;\n    min-width: 0;\n}\n\n.flex-item img {\n    width: 100%;\n    display: block;\n}\n\n.parameters-table-wrapper {\n    overflow-x: auto;\n    -webkit-overflow-scrolling: touch;\n}\n\n.parameters-table {\n    width: 100%;\n    min-width: 1000px;\n    border-collapse: collapse;\n    font-family: Arial;\n}\n\n.parameters-table th,\n.parameters-table td {\n    border-top: 1.2px solid #a6a6a6;\n    border-bottom: 1.2px solid #a6a6a6;\n    padding: 5px 2px;\n    text-align: left;\n    font-size: 16px;\n}\n\n.parameters-table th,\n.parameters-table .bg-gray {\n    background-color: #f2f2f2;\n    font-weight: bold;\n}\n\n.bg-gray {\n    color: black;\n    font-weight: bold;\n}\n\n@media (max-width: 768px) {\n    .desktop-img { display: none; }\n    .mobile-img { display: block; }\n    .flex-row {\n        flex-direction: column;\n        gap: 10px;\n    }\n    .parameters-table th,\n    .parameters-table td {\n        font-size: 14px;\n    }\n}\n\n@media (max-width: 480px) {\n    .parameters-table th,\n    .parameters-table td {\n        font-size: 12px;\n    }\n}\n\n\/* Prevent horizontal overflow in storefront content areas. *\/\nhtml, body { max-width: 100%; overflow-x: hidden; }\n.parameters-table-wrapper { width: 100%; max-width: 100%; overflow-x: hidden; }\n.parameters-table { width: 100%; max-width: 100%; min-width: 0; table-layout: fixed; }\n.parameters-table th, .parameters-table td { overflow-wrap: anywhere; word-break: break-word; }\nimg { max-width: 100%; height: auto; }\n\u003c\/style\u003e\n\u003c!-- Cover Image --\u003e\n\u003cp\u003e\n\u003cimg alt=\"\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\"\u003e\n\u003cimg alt=\"\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\"\u003e\n\u003c\/p\u003e\n\u003c!-- INTRODUCTION --\u003e\n\u003ch2 class=\"section-title\"\u003eINTRODUCTION\u003c\/h2\u003e\u003cp class=\"section-description\"\u003eThe U.S. Solid UPVC Motorized Ball Valve combines automatic flow control with a service-friendly double union design. Powered by 110-230V AC and supplied with a US plug, it opens when power is applied and automatically returns to the closed position when power is disconnected. The corrosion-resistant UPVC body features a full-port flow path to help minimize restriction, while NPT threaded connections integrate with matching piping. The IP67-rated actuator enclosure helps protect internal components against dust and water ingress. Detachable union connections make it easy to remove the valve body for cleaning and inspection without cutting the connected pipes. A built-in manual override provides control when electrical power is unavailable, and the position indicator offers a convenient visual reference for valve status. This SKU is the 1-1\/4 inch NPT version. Select a size that matches your piping system. Before operation, allow 1-2 minutes of power-on time for the internal capacitor to charge and support automatic return. Follow the supplied instructions for installation and manual operation.\u003c\/p\u003e\n\u003c!-- FEATURES --\u003e\n\u003ch2 class=\"section-title\"\u003eFEATURES\u003c\/h2\u003e\n\u003cp\u003e\n\u003cimg alt=\"\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/1.png\"\u003e\n\u003cimg alt=\"\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/1.png\"\u003e\n\u003c\/p\u003e\n\u003c!-- MORE DETAILS --\u003e\n\u003ch2 class=\"section-title3\"\u003eMORE DETAILS\u003c\/h2\u003e\n\u003cdiv class=\"flex-row\"\u003e\n\u003cdiv class=\"flex-item\"\u003e\n\u003ch2 class=\"section-title4 title-center\"\u003eMANUAL OVERRIDE\u003c\/h2\u003e\n\u003cimg alt=\"GIF 1\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/jfesm50020-more1.png\"\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"flex-item\"\u003e\n\u003ch2 class=\"section-title4 title-center\"\u003eDETACHABLE DESIGN\u003c\/h2\u003e\n\u003cimg alt=\"GIF 2\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/jfesm50020-more2.jpg\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- APPLICATIONS --\u003e\n\u003ch2 class=\"section-title2\"\u003eAPPLICATIONS\u003c\/h2\u003e\n\u003cp\u003e\n\u003cimg alt=\"\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\"\u003e\n\u003c\/p\u003e\n\u003c!-- OPERATION PERFORMANCE --\u003e\n\u003ch2 class=\"section-title3\"\u003eOPERATION PERFORMANCE\u003c\/h2\u003e\n\u003cdiv class=\"flex-row\"\u003e\n\u003cdiv class=\"flex-item\"\u003e\n\u003ch2 class=\"section-title4 title-center\"\u003eAFTER WIRING\u003c\/h2\u003e\n\u003cimg alt=\"GIF 1\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\"\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"flex-item\"\u003e\n\u003ch2 class=\"section-title4 title-center\"\u003eDISCONNECT THE WIRING\u003c\/h2\u003e\n\u003cimg alt=\"GIF 2\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- SPECIFICATIONS --\u003e\n\u003ch2 class=\"section-title3\"\u003eSPECIFICATIONS\u003c\/h2\u003e\n\u003cdiv class=\"parameters-table-wrapper\"\u003e\n\u003ctable class=\"parameters-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003eModel\u003c\/td\u003e\n\u003ctd\u003eUSS-MSV50016\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eU.S. Solid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003eSize\u003c\/td\u003e\n\u003ctd\u003e1-1\/4\"\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003eWiring Type\u003c\/td\u003e\n\u003ctd\u003ePlug Auto Return\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003eValve Material\u003c\/td\u003e\n\u003ctd\u003eUPVC\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003eEnclosure Rating\u003c\/td\u003e\n\u003ctd\u003eIP67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003eOperating Time\u003c\/td\u003e\n\u003ctd\u003e≤ 12 s\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003eWorking Voltage\u003c\/td\u003e\n\u003ctd\u003eAC 110-230V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003eMax Power\u003c\/td\u003e\n\u003ctd\u003e36 W\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003eMax Torque\u003c\/td\u003e\n\u003ctd\u003e15 Nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003eMax Medium Pressure\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 10 bar\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003eTemperature Range for Flow Medium\u003c\/td\u003e\n\u003ctd\u003e2 ~ 55 ℃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003eLife Expectancy\u003c\/td\u003e\n\u003ctd\u003e70000 Cycles\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003eBore Type\u003c\/td\u003e\n\u003ctd\u003eFull Port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003eOperating State\u003c\/td\u003e\n\u003ctd\u003eNormally Closed\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003eAmbient Temperature Range\u003c\/td\u003e\n\u003ctd\u003e-15 ~ 50 ℃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003eValve Seat\u003c\/td\u003e\n\u003ctd\u003ePTFE\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003eO-Ring Seal\u003c\/td\u003e\n\u003ctd\u003eEPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003eManual Reset Included\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003eSuitable Media\u003c\/td\u003e\n\u003ctd\u003eAir, Water\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003ePosition Indicator\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003eFlow Aperture\u003c\/td\u003e\n\u003ctd\u003e32 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c!-- CE CERTIFIED QUALITY \u0026 SAFETY --\u003e\n\u003ch2 class=\"section-title3\"\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/h2\u003e\n\u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/CE\/CE.jpg\"\u003e\n\u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/CE\/CE.jpg\"\u003e\n\u003c!-- FAQ --\u003e\n\u003ch2 class=\"section-title\"\u003eFAQ\u003c\/h2\u003e\n\u003cp class=\"faq\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\nThe motor's housing is rated at IP67 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\n\u003c\/p\u003e\n\u003cp class=\"faq\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\nIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\n\u003c\/p\u003e\n\u003cp class=\"faq\"\u003e\u003cb\u003e3. What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\nIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\n\u003c\/p\u003e\n\u003cp class=\"faq\"\u003e\u003cb\u003e4. Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003eThe specifications list air and water as compatible media. Check applicable approvals before using the valve in potable water systems.\u003c\/p\u003e\n\u003cp class=\"faq\"\u003e\u003cb\u003e5. For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003eTo support automatic return, allow the internal capacitor to charge for 1-2 minutes before disconnecting power.\u003c\/p\u003e\n\u003cp class=\"faq\"\u003e\u003cb\u003e6. Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003eThe specifications list air and water as compatible media. Propane is not listed; confirm compatibility before using the valve with other media.\u003c\/p\u003e\n\u003c!-- WARNING --\u003e\n\u003ch2 class=\"section-title\"\u003eWARNING\u003c\/h2\u003e\n\u003cp class=\"section-description\"\u003e\n\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\n\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003eUse the built-in manual override as described in the product instructions. Do not force the actuator or valve body by hand.\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\n\u003cb\u003e3.\u003c\/b\u003e Only Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\n\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\n\u003cb\u003e4.\u003c\/b\u003e While the motorized ball valves have an IP67 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\n\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\n\u003cb\u003e5.\u003c\/b\u003e These valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\n\u003c\/p\u003e\n\u003c!-- Valve Attributes --\u003e\n\u003ch2 class=\"section-title\"\u003eValve Attributes\u003c\/h2\u003e\n\u003cp class=\"section-description\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\nNormally Closed: The valve is closed when power is off and opens when power is on.\n\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\nNormally Open: The valve is open when power is off and closes when power is on.\n\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\nFull Port: It has a wide internal passage, resulting in low water - flow resistance.\n\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\nStandard Port: Meets regular usage requirements.\n\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\nThe valves have an ingress - protection rating of IP67. The 6 in IP67 represents complete dust - tightness. The 7 in IP67 indicates protection against water immersion up to 1 meter for 30 minutes. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\n\u003c\/p\u003e\n\u003cp\u003e\n\u003cimg alt=\"\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/IP67-UPVC.png\"\u003e\n\u003c\/p\u003e\n\u003c!-- Valve Attributes --\u003e\n\u003ch2 class=\"section-title\"\u003eWIRING SCHEMATICS\u003c\/h2\u003e\n\u003cp\u003e\n\u003cimg alt=\"\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\"\u003e\n\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003eTo support automatic return, allow the internal capacitor to charge for 1-2 minutes before disconnecting power.\u003c\/p\u003e\n\u003c!-- CHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS --\u003e\n\u003ch2 class=\"section-title3\"\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS \u0026amp; SAFETY\u003c\/h2\u003e\n\u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material.png\"\u003e\n\u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material-APP.png\"\u003e\n\u003cp class=\"section-description\"\u003e\nDownload user manual\n\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/Manual-50020-28.pdf\" target=\"_blank\"\u003ehere\u003c\/a\u003e.\n\u003c\/p\u003e","brand":"U.S. Solid","offers":[{"title":"Default Title","offer_id":50746914242815,"sku":"JFMSV50016","price":189.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/jfmsv50016-1.png?v=1792633158"}],"url":"https:\/\/ussolid.com\/collections\/110-230v-ac-motorized-ball-valves-html.oembed?page=4","provider":"U.S. Solid","version":"1.0","type":"link"}