{"title":"Electric Actuated Ball Valve","description":"\u003cp\u003eU.S. Solid Electric Actuated Ball Valves deliver precise, heavy-duty control for advanced industrial fluid systems, seamlessly bridging electronic control networks and mechanical piping. Torque-optimized, these valves are engineered for direct integration with PLCs and complex automation architectures.\u003cbr\u003eWe offer versatile configurations to meet diverse system needs: standard ON\/OFF or modulating servo control, multi-port routing, and multiple feedback options. Built for harsh environments, they feature industrial-grade IP65 to IP67 protection and wide operating temperature ranges.\u003cbr\u003eOur 3-piece threaded ball valves feature a specialized three-piece body structure. This design allows the center section—containing the ball, stem, and seats—to swing out for independent servicing. Technicians can perform rapid, in-line maintenance and seal replacements without disrupting pipe connections, significantly reducing system downtime.\u003c\/p\u003e","products":[{"product_id":"1-2-electric-actuated-ball-valve-heavy-duty-3-piece-industrial-ball-valve-304ss","title":"1\/2\" Electric Actuated Ball Valve, 110V AC Heavy Duty 3-Piece Industrial Ball Valve,304SS, ON\/OFF Type, Dry Contact","description":"\u003cstyle\u003e\n  .mobile-only {\n    display: none;\n  }\n\n  .desktop-only img,\n  .mobile-only img {\n    max-width: 100%;\n    height: auto;\n  }\n\n  @media only screen and (max-width: 600px) {\n    .desktop-only {\n      display: none !important;\n    }\n\n    .mobile-only {\n      display: block !important;\n      font-family: Arial, sans-serif;\n      color: black;\n    }\n\n    .mobile-only table {\n      min-width: 620px;\n    }\n\n    .mobile-only ul {\n      padding-left: 18px !important;\n    }\n  }\n\n  @media only screen and (min-width: 601px) {\n    .desktop-only {\n      display: block !important;\n    }\n\n    .mobile-only {\n      display: none !important;\n    }\n  }\n\u003c\/style\u003e\n\n\u003cdiv class=\"desktop-only\" style=\"font-family: Arial, sans-serif; color: black;\"\u003e\n\u003ch3 style=\"margin-bottom: 20px; margin-top: 0;\"\u003e\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/%E6%9D%A1%E7%8A%B6%E5%9B%BE.jpg\" style=\"width: 100%; max-width: 100%; height: auto; display: block;\" alt=\"Product Introduction\"\u003e\u003c\/h3\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top: 0px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; line-height: 26px; font-family: Arial; color: black; margin-bottom: 20px;\"\u003eThis premium flow control solution integrates a heavy-duty 3-piece stainless steel ball valve with a high-performance electric actuator. Engineered for reliability and precision, it provides a comprehensive hardware suite for automated systems, offering superior durability, seamless integration, and simplified maintenance in demanding industrial environments.\u003c\/p\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"margin-bottom: 20px; text-align: center;\"\u003e\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/FEATURES.webp\" alt=\"\"\u003e\u003c\/div\u003e\n\u003cul style=\"font-size: 16px; line-height: 26px; color: black; font-family: Arial; margin-bottom: 20px; padding-left: 20px;\"\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003ePremium Material Construction:\u003c\/strong\u003e Crafted from high-grade 304 stainless steel, the valve body is highly resistant to corrosion, making it suitable for handling weak acids, weak alkalis, chemical solvents, and water.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eMaintenance-Friendly 3-Piece Design:\u003c\/strong\u003e The innovative 3-piece body construction allows for seamless in-line maintenance. Internal components can be easily cleaned or replaced without the need to disconnect the pipes, significantly reducing downtime and service costs.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eHigh-Pressure \u0026amp; Full-Bore Efficiency:\u003c\/strong\u003e Designed for maximum performance, the full-bore configuration guarantees minimal pressure drop, ensuring optimal flow capacity even in high-pressure systems.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eSmart Automation Ready:\u003c\/strong\u003e Equipped with integrated limit switches and position feedback, the actuator allows for seamless integration with PLC systems, enabling precise remote control, real-time monitoring, and full automation in complex industrial processes.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eHigh-Torque Reliability:\u003c\/strong\u003e Powered by a compact yet robust heavy-duty motor, the actuator delivers a steady torque of 50Nm, ensuring consistent full-port opening and reliable drop-tight sealing for every cycle.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eEnhanced Safety \u0026amp; Self-Locking:\u003c\/strong\u003e The actuator features an integrated self-locking mechanism to ensure valve stability and system integrity. Additionally, a built-in manual override port ensures safe, reliable intervention during power outages or emergencies.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eRugged Outdoor Durability:\u003c\/strong\u003e Engineered for the elements, the unit is encased in a powder-coated polyester aluminum housing, providing exceptional resistance to corrosion and harsh weather.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eAdvanced Circuitry Protection:\u003c\/strong\u003e To ensure long-term electrical reliability, the internal PCBA is treated with a protective sealant, effectively preventing damage from moisture, condensation, and short circuits.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px;\"\u003e\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/Application.png\" style=\"width: 100%; max-width: 100%; height: auto; display: block;\" alt=\"Applications\"\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eWIRING DIAGRAMS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 15px; margin-bottom: 20px;\"\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/Wiring-AB.jpg\" style=\"flex: 1; min-width: 280px; max-width: 100%; height: auto;\" alt=\"Wiring Diagram 1\"\u003e \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/Wiring-CD.jpg\" style=\"flex: 1; min-width: 280px; max-width: 100%; height: auto;\" alt=\"Wiring Diagram 2\"\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eELECTRIC WIRING\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 20px; margin-bottom: 20px;\"\u003e\n\u003cdiv style=\"flex: 1; min-width: 280px; text-align: center;\"\u003e\n\u003ch4 style=\"font-size: 16px; margin-top: 0; margin-bottom: 10px;\"\u003e\u003cstrong\u003e[OPEN]\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/JFHDBV-OPEN.gif\" alt=\"OPEN\" style=\"width: 100%; max-width: 450px; height: auto;\"\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; min-width: 280px; text-align: center;\"\u003e\n\u003ch4 style=\"font-size: 16px; margin-top: 0; margin-bottom: 10px;\"\u003e\u003cstrong\u003e[CLOSED]\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/JFHDBV-CLOSED.gif\" alt=\"CLOSED\" style=\"width: 100%; max-width: 450px; height: auto;\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"width: 100%; overflow-x: auto; margin-bottom: 20px;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; background-color: rgb(255, 255, 255); font-size: 16px; font-family: Arial; color: black; height: 425.521px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 22.3958px;\"\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; text-align: center; height: 22.3958px;\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px; height: 22.3958px;\"\u003eUSS-HDBV00011\u003c\/td\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; text-align: center; height: 22.3958px;\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px; height: 22.3958px;\"\u003eU.S. Solid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 44.7917px;\"\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eSize\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 44.7917px;\"\u003e1\/2\"\u003c\/td\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eWiring Type\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 44.7917px;\"\u003eType B: ON\/OFF Type, Dry Contact\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 44.7917px;\"\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eValve Material\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 44.7917px;\"\u003e304SS\u003c\/td\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eBall Seal\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 44.7917px;\"\u003ePTFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 44.7917px;\"\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eOperating Time\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 44.7917px;\"\u003e20 Seconds\u003c\/td\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eWorking Voltage\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 44.7917px;\"\u003e110V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 22.3958px;\"\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 22.3958px;\"\u003eMax Power\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 22.3958px;\"\u003e20 W\u003c\/td\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 22.3958px;\"\u003eMax Torque\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 22.3958px;\"\u003e50 N m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 89.5833px;\"\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 89.5833px;\"\u003eMax Medium Pressure\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 89.5833px;\"\u003e1.6 Mpa\u003c\/td\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 89.5833px;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 89.5833px;\"\u003e-30°C to 180°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 44.7917px;\"\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eLife Expectancy\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 44.7917px;\"\u003e30,000 to 50,000 Cycles\u003c\/td\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eBore Type\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 44.7917px;\"\u003eFull port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 44.7917px;\"\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eThread Type\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 44.7917px;\"\u003eNPT\u003c\/td\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eOperating State\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 44.7917px;\"\u003eRemain in position\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 67.1875px;\"\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 67.1875px;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 67.1875px;\"\u003e-30°C to 60°C\u003c\/td\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 67.1875px;\"\u003eEnclosure Rating\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 67.1875px;\"\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eWARNINGS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"font-size: 16px; line-height: 26px; color: black; font-family: Arial; margin-bottom: 20px; padding-left: 20px;\"\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003ePower Failure Behavior:\u003c\/strong\u003e This valve remains in its current position during a power outage. It does not automatically return to a preset position.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eVoltage Match Required:\u003c\/strong\u003e Supply voltage must match the actuator rating exactly. Incorrect voltage may permanently damage the unit.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eDedicated Power Circuit:\u003c\/strong\u003e Each actuator requires its own fuse-protected power supply. Do not connect multiple actuators in parallel.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eDisconnect Power Before Service:\u003c\/strong\u003e Always disconnect power before wiring, maintenance, or using the manual override.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eIP65 Weather Resistant:\u003c\/strong\u003e Suitable for outdoor use, but additional protection is recommended for permanent outdoor installations.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eLow Power Consumption:\u003c\/strong\u003e Power is only used during opening and closing. No power is consumed when fully open or fully closed.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eProfessional Installation Recommended:\u003c\/strong\u003e Installation should be performed by qualified personnel familiar with electrical control systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"font-size: 16px; line-height: 26px; font-family: Arial; color: black; margin-bottom: 20px;\"\u003e\n\u003cp style=\"margin-bottom: 10px;\"\u003e\u003cstrong\u003e1: Can I manually operate the valve?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px; padding-left: 15px;\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes. The actuator features a manual override. We recommend manually cycling the valve before installation to verify smooth operation, and using the adjustment screws during commissioning to fine-tune open\/close positions.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 10px;\"\u003e\u003cstrong\u003e2: Can this valve be installed outdoors?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px; padding-left: 15px;\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes, depending on your model's IP rating. While our heavy-duty actuators are weather-resistant, we highly recommend using a protective cover or shelter for permanent outdoor installations to shield the unit from direct UV rays and ice buildup.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 10px;\"\u003e\u003cstrong\u003e3: Is this valve suitable for high-viscosity fluids or particulates?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px; padding-left: 15px;\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes, but with torque considerations. Our heavy-duty series is built for high-torque applications. However, extremely viscous mediums or large particulates will increase resistance. Ensure the operating torque remains within the actuator's rated capacity to avoid stalling.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 10px;\"\u003e\u003cstrong\u003e4: Is it normal for the actuator to feel hot during operation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px; padding-left: 15px;\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes, it is normal to feel warm during continuous cycling. The actuator includes built-in power-limiting features to prevent overheating under normal use. If the housing becomes too hot to touch, please check that you are not exceeding the recommended duty cycle or the ambient temperature limit (-30°C to +60°C).\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 10px;\"\u003e\u003cstrong\u003e5: Can I wire multiple actuators in parallel on the same circuit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px; padding-left: 15px;\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e No. Each motorized actuator must be installed on its own dedicated, fuse-protected circuit to ensure proper signal response and prevent electrical interference or damage.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 16px; margin-top: 25px;\"\u003eDownload user manual \u003ca href=\"http:\/\/file.ussolid.com\/content\/JFHDBV\/JFHDBV-%20Electric%20Actuated%20Ball%20Valve%20instruction%20manual.pdf\" rel=\"noopener\" style=\"color: #0066cc; text-decoration: underline;\" target=\"_blank\"\u003ehere\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"mobile-only\" style=\"font-family: Arial, sans-serif; color: black;\"\u003e\n\u003ch3 style=\"margin-bottom: 20px; margin-top: 0;\"\u003e\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/%E6%9D%A1%E7%8A%B6%E5%9B%BE.jpg\" style=\"width: 100%; max-width: 100%; height: auto; display: block;\" alt=\"Product Introduction\"\u003e\u003c\/h3\u003e\n\u003cp style=\"font-size: 20px; font-family: Arial; text-align: left; margin-top: 0px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 15px; line-height: 24px; font-family: Arial; color: black; margin-bottom: 20px;\"\u003eThis premium flow control solution integrates a heavy-duty 3-piece stainless steel ball valve with a high-performance electric actuator. Engineered for reliability and precision, it provides a comprehensive hardware suite for automated systems, offering superior durability, seamless integration, and simplified maintenance in demanding industrial environments.\u003c\/p\u003e\n\u003cp style=\"font-size: 20px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"margin-bottom: 20px; text-align: center;\"\u003e\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/FEATURES.webp\" alt=\"\"\u003e\u003c\/div\u003e\n\u003cul style=\"font-size: 15px; line-height: 24px; color: black; font-family: Arial; margin-bottom: 20px; padding-left: 20px;\"\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003ePremium Material Construction:\u003c\/strong\u003e Crafted from high-grade 304 stainless steel, the valve body is highly resistant to corrosion, making it suitable for handling weak acids, weak alkalis, chemical solvents, and water.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eMaintenance-Friendly 3-Piece Design:\u003c\/strong\u003e The innovative 3-piece body construction allows for seamless in-line maintenance. Internal components can be easily cleaned or replaced without the need to disconnect the pipes, significantly reducing downtime and service costs.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eHigh-Pressure \u0026amp; Full-Bore Efficiency:\u003c\/strong\u003e Designed for maximum performance, the full-bore configuration guarantees minimal pressure drop, ensuring optimal flow capacity even in high-pressure systems.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eSmart Automation Ready:\u003c\/strong\u003e Equipped with integrated limit switches and position feedback, the actuator allows for seamless integration with PLC systems, enabling precise remote control, real-time monitoring, and full automation in complex industrial processes.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eHigh-Torque Reliability:\u003c\/strong\u003e Powered by a compact yet robust heavy-duty motor, the actuator delivers a steady torque of 50Nm, ensuring consistent full-port opening and reliable drop-tight sealing for every cycle.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eEnhanced Safety \u0026amp; Self-Locking:\u003c\/strong\u003e The actuator features an integrated self-locking mechanism to ensure valve stability and system integrity. Additionally, a built-in manual override port ensures safe, reliable intervention during power outages or emergencies.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eRugged Outdoor Durability:\u003c\/strong\u003e Engineered for the elements, the unit is encased in a powder-coated polyester aluminum housing, providing exceptional resistance to corrosion and harsh weather.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eAdvanced Circuitry Protection:\u003c\/strong\u003e To ensure long-term electrical reliability, the internal PCBA is treated with a protective sealant, effectively preventing damage from moisture, condensation, and short circuits.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size: 20px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px;\"\u003e\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/Application.png\" style=\"width: 100%; max-width: 100%; height: auto; display: block;\" alt=\"Applications\"\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 20px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eWIRING DIAGRAMS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; gap: 12px; margin-bottom: 20px;\"\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/Wiring-AB.jpg\" style=\"width: 100%; max-width: 100%; height: auto; display: block;\" alt=\"Wiring Diagram 1\"\u003e \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/Wiring-CD.jpg\" style=\"width: 100%; max-width: 100%; height: auto; display: block;\" alt=\"Wiring Diagram 2\"\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 20px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eELECTRIC WIRING\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; gap: 15px; margin-bottom: 20px;\"\u003e\n\u003cdiv style=\"width: 100%; text-align: center;\"\u003e\n\u003ch4 style=\"font-size: 15px; margin-top: 0; margin-bottom: 10px;\"\u003e\u003cstrong\u003e[OPEN]\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/JFHDBV-OPEN.gif\" alt=\"OPEN\" style=\"width: 100%; max-width: 100%; height: auto;\"\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"width: 100%; text-align: center;\"\u003e\n\u003ch4 style=\"font-size: 15px; margin-top: 0; margin-bottom: 10px;\"\u003e\u003cstrong\u003e[CLOSED]\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/JFHDBV-CLOSED.gif\" alt=\"CLOSED\" style=\"width: 100%; max-width: 100%; height: auto;\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 20px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"width: 100%; overflow-x: auto; margin-bottom: 20px;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; background-color: rgb(255, 255, 255); font-size: 15px; font-family: Arial; color: black; height: 425.521px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 22.3958px;\"\u003e\n\u003cth style=\"width: 20%; padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; text-align: center; height: 22.3958px;\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 6px; height: 22.3958px;\"\u003eUSS-HDBV00011\u003c\/td\u003e\n\u003cth style=\"width: 20%; padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; text-align: center; height: 22.3958px;\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 6px; height: 22.3958px;\"\u003eU.S. Solid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 44.7917px;\"\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eSize\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 44.7917px;\"\u003e1\/2\"\u003c\/td\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eWiring Type\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 44.7917px;\"\u003eType B: ON\/OFF Type, Dry Contact\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 44.7917px;\"\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eValve Material\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 44.7917px;\"\u003e304SS\u003c\/td\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eBall Seal\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 44.7917px;\"\u003ePTFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 44.7917px;\"\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eOperating Time\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 44.7917px;\"\u003e20 Seconds\u003c\/td\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eWorking Voltage\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 44.7917px;\"\u003e110V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 22.3958px;\"\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 22.3958px;\"\u003eMax Power\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 22.3958px;\"\u003e20 W\u003c\/td\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 22.3958px;\"\u003eMax Torque\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 22.3958px;\"\u003e50 N m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 89.5833px;\"\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 89.5833px;\"\u003eMax Medium Pressure\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 89.5833px;\"\u003e1.6 Mpa\u003c\/td\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 89.5833px;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 89.5833px;\"\u003e-30°C to 180°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 44.7917px;\"\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eLife Expectancy\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 44.7917px;\"\u003e30,000 to 50,000 Cycles\u003c\/td\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eBore Type\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 44.7917px;\"\u003eFull port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 44.7917px;\"\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eThread Type\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 44.7917px;\"\u003eNPT\u003c\/td\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eOperating State\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 44.7917px;\"\u003eRemain in position\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 67.1875px;\"\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 67.1875px;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 67.1875px;\"\u003e-30°C to 60°C\u003c\/td\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 67.1875px;\"\u003eEnclosure Rating\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 67.1875px;\"\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 20px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eWARNINGS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"font-size: 15px; line-height: 24px; color: black; font-family: Arial; margin-bottom: 20px; padding-left: 20px;\"\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003ePower Failure Behavior:\u003c\/strong\u003e This valve remains in its current position during a power outage. It does not automatically return to a preset position.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eVoltage Match Required:\u003c\/strong\u003e Supply voltage must match the actuator rating exactly. Incorrect voltage may permanently damage the unit.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eDedicated Power Circuit:\u003c\/strong\u003e Each actuator requires its own fuse-protected power supply. Do not connect multiple actuators in parallel.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eDisconnect Power Before Service:\u003c\/strong\u003e Always disconnect power before wiring, maintenance, or using the manual override.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eIP65 Weather Resistant:\u003c\/strong\u003e Suitable for outdoor use, but additional protection is recommended for permanent outdoor installations.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eLow Power Consumption:\u003c\/strong\u003e Power is only used during opening and closing. No power is consumed when fully open or fully closed.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eProfessional Installation Recommended:\u003c\/strong\u003e Installation should be performed by qualified personnel familiar with electrical control systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size: 20px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"font-size: 15px; line-height: 24px; font-family: Arial; color: black; margin-bottom: 20px;\"\u003e\n\u003cp style=\"margin-bottom: 10px;\"\u003e\u003cstrong\u003e1: Can I manually operate the valve?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px; padding-left: 15px;\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes. The actuator features a manual override. We recommend manually cycling the valve before installation to verify smooth operation, and using the adjustment screws during commissioning to fine-tune open\/close positions.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 10px;\"\u003e\u003cstrong\u003e2: Can this valve be installed outdoors?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px; padding-left: 15px;\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes, depending on your model's IP rating. While our heavy-duty actuators are weather-resistant, we highly recommend using a protective cover or shelter for permanent outdoor installations to shield the unit from direct UV rays and ice buildup.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 10px;\"\u003e\u003cstrong\u003e3: Is this valve suitable for high-viscosity fluids or particulates?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px; padding-left: 15px;\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes, but with torque considerations. Our heavy-duty series is built for high-torque applications. However, extremely viscous mediums or large particulates will increase resistance. Ensure the operating torque remains within the actuator's rated capacity to avoid stalling.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 10px;\"\u003e\u003cstrong\u003e4: Is it normal for the actuator to feel hot during operation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px; padding-left: 15px;\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes, it is normal to feel warm during continuous cycling. The actuator includes built-in power-limiting features to prevent overheating under normal use. If the housing becomes too hot to touch, please check that you are not exceeding the recommended duty cycle or the ambient temperature limit (-30°C to +60°C).\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 10px;\"\u003e\u003cstrong\u003e5: Can I wire multiple actuators in parallel on the same circuit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px; padding-left: 15px;\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e No. Each motorized actuator must be installed on its own dedicated, fuse-protected circuit to ensure proper signal response and prevent electrical interference or damage.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 15px; margin-top: 25px;\"\u003eDownload user manual \u003ca href=\"http:\/\/file.ussolid.com\/content\/JFHDBV\/JFHDBV-%20Electric%20Actuated%20Ball%20Valve%20instruction%20manual.pdf\" rel=\"noopener\" style=\"color: #0066cc; text-decoration: underline;\" target=\"_blank\"\u003ehere\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n","brand":"U.S. Solid","offers":[{"title":"Default Title","offer_id":48278856139007,"sku":"JFHDBV00011","price":209.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/2_2f54ce57-deba-4dd9-b2fd-4323d61cd792.jpg?v=1777446926"},{"product_id":"3-4-electric-actuated-ball-valve-heavy-duty-3-piece-industrial-ball-valve-304ss","title":"3\/4\" Electric Actuated Ball Valve, 110V AC Heavy Duty 3-Piece Industrial Ball Valve,304SS, ON\/OFF Type, Dry Contact","description":"\u003cstyle\u003e\n  .mobile-only {\n    display: none;\n  }\n\n  .desktop-only img,\n  .mobile-only img {\n    max-width: 100%;\n    height: auto;\n  }\n\n  @media only screen and (max-width: 600px) {\n    .desktop-only {\n      display: none !important;\n    }\n\n    .mobile-only {\n      display: block !important;\n      font-family: Arial, sans-serif;\n      color: black;\n    }\n\n    .mobile-only table {\n      min-width: 620px;\n    }\n\n    .mobile-only ul {\n      padding-left: 18px !important;\n    }\n  }\n\n  @media only screen and (min-width: 601px) {\n    .desktop-only {\n      display: block !important;\n    }\n\n    .mobile-only {\n      display: none !important;\n    }\n  }\n\u003c\/style\u003e\n\u003cdiv style=\"font-family: Arial, sans-serif; color: black;\" class=\"desktop-only\"\u003e\n\u003ch3 style=\"margin-bottom: 20px; margin-top: 0;\"\u003e\u003cimg alt=\"Product Introduction\" style=\"width: 100%; max-width: 100%; height: auto; display: block;\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/%E6%9D%A1%E7%8A%B6%E5%9B%BE.jpg\"\u003e\u003c\/h3\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top: 0px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; line-height: 26px; font-family: Arial; color: black; margin-bottom: 20px;\"\u003eThis premium flow control solution integrates a heavy-duty 3-piece stainless steel ball valve with a high-performance electric actuator. Engineered for reliability and precision, it provides a comprehensive hardware suite for automated systems, offering superior durability, seamless integration, and simplified maintenance in demanding industrial environments.\u003c\/p\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"margin-bottom: 20px; text-align: center;\"\u003e\u003cimg alt=\"\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/FEATURES.webp\"\u003e\u003c\/div\u003e\n\u003cul style=\"font-size: 16px; line-height: 26px; color: black; font-family: Arial; margin-bottom: 20px; padding-left: 20px;\"\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003ePremium Material Construction:\u003c\/strong\u003e Crafted from high-grade 304 stainless steel, the valve body is highly resistant to corrosion, making it suitable for handling weak acids, weak alkalis, chemical solvents, and water.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eMaintenance-Friendly 3-Piece Design:\u003c\/strong\u003e The innovative 3-piece body construction allows for seamless in-line maintenance. Internal components can be easily cleaned or replaced without the need to disconnect the pipes, significantly reducing downtime and service costs.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eHigh-Pressure \u0026amp; Full-Bore Efficiency:\u003c\/strong\u003e Designed for maximum performance, the full-bore configuration guarantees minimal pressure drop, ensuring optimal flow capacity even in high-pressure systems.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eSmart Automation Ready:\u003c\/strong\u003e Equipped with integrated limit switches and position feedback, the actuator allows for seamless integration with PLC systems, enabling precise remote control, real-time monitoring, and full automation in complex industrial processes.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eHigh-Torque Reliability:\u003c\/strong\u003e Powered by a compact yet robust heavy-duty motor, the actuator delivers a steady torque of 50Nm, ensuring consistent full-port opening and reliable drop-tight sealing for every cycle.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eEnhanced Safety \u0026amp; Self-Locking:\u003c\/strong\u003e The actuator features an integrated self-locking mechanism to ensure valve stability and system integrity. Additionally, a built-in manual override port ensures safe, reliable intervention during power outages or emergencies.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eRugged Outdoor Durability:\u003c\/strong\u003e Engineered for the elements, the unit is encased in a powder-coated polyester aluminum housing, providing exceptional resistance to corrosion and harsh weather.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eAdvanced Circuitry Protection:\u003c\/strong\u003e To ensure long-term electrical reliability, the internal PCBA is treated with a protective sealant, effectively preventing damage from moisture, condensation, and short circuits.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px;\"\u003e\u003cimg alt=\"Applications\" style=\"width: 100%; max-width: 100%; height: auto; display: block;\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/Application.png\"\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eWIRING DIAGRAMS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 15px; margin-bottom: 20px;\"\u003e\n\u003cimg alt=\"Wiring Diagram 1\" style=\"flex: 1; min-width: 280px; max-width: 100%; height: auto;\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/Wiring-AB.jpg\"\u003e \u003cimg alt=\"Wiring Diagram 2\" style=\"flex: 1; min-width: 280px; max-width: 100%; height: auto;\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/Wiring-CD.jpg\"\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eELECTRIC WIRING\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 20px; margin-bottom: 20px;\"\u003e\n\u003cdiv style=\"flex: 1; min-width: 280px; text-align: center;\"\u003e\n\u003ch4 style=\"font-size: 16px; margin-top: 0; margin-bottom: 10px;\"\u003e\u003cstrong\u003e[OPEN]\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cimg style=\"width: 100%; max-width: 450px; height: auto;\" alt=\"OPEN\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/JFHDBV-OPEN.gif\"\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; min-width: 280px; text-align: center;\"\u003e\n\u003ch4 style=\"font-size: 16px; margin-top: 0; margin-bottom: 10px;\"\u003e\u003cstrong\u003e[CLOSED]\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cimg style=\"width: 100%; max-width: 450px; height: auto;\" alt=\"CLOSED\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/JFHDBV-CLOSED.gif\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"width: 100%; overflow-x: auto; margin-bottom: 20px;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; background-color: rgb(255, 255, 255); font-size: 16px; font-family: Arial; color: black; height: 425.521px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 22.3958px;\"\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; text-align: center; height: 22.3958px;\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px; height: 22.3958px;\"\u003eUSS-HDBV00011\u003c\/td\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; text-align: center; height: 22.3958px;\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px; height: 22.3958px;\"\u003eU.S. Solid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 44.7917px;\"\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eSize\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 44.7917px;\"\u003e1\/2\"\u003c\/td\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eWiring Type\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 44.7917px;\"\u003eType B: ON\/OFF Type, Dry Contact\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 44.7917px;\"\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eValve Material\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 44.7917px;\"\u003e304SS\u003c\/td\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eBall Seal\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 44.7917px;\"\u003ePTFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 44.7917px;\"\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eOperating Time\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 44.7917px;\"\u003e20 Seconds\u003c\/td\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eWorking Voltage\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 44.7917px;\"\u003e110V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 22.3958px;\"\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 22.3958px;\"\u003eMax Power\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 22.3958px;\"\u003e20 W\u003c\/td\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 22.3958px;\"\u003eMax Torque\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 22.3958px;\"\u003e50 N m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 89.5833px;\"\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 89.5833px;\"\u003eMax Medium Pressure\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 89.5833px;\"\u003e1.6 Mpa\u003c\/td\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 89.5833px;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 89.5833px;\"\u003e-30°C to 180°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 44.7917px;\"\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eLife Expectancy\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 44.7917px;\"\u003e30,000 to 50,000 Cycles\u003c\/td\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eBore Type\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 44.7917px;\"\u003eFull port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 44.7917px;\"\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eThread Type\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 44.7917px;\"\u003eNPT\u003c\/td\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eOperating State\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 44.7917px;\"\u003eRemain in position\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 67.1875px;\"\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 67.1875px;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 67.1875px;\"\u003e-30°C to 60°C\u003c\/td\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 67.1875px;\"\u003eEnclosure Rating\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 67.1875px;\"\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eWARNINGS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"font-size: 16px; line-height: 26px; color: black; font-family: Arial; margin-bottom: 20px; padding-left: 20px;\"\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003ePower Failure Behavior:\u003c\/strong\u003e This valve remains in its current position during a power outage. It does not automatically return to a preset position.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eVoltage Match Required:\u003c\/strong\u003e Supply voltage must match the actuator rating exactly. Incorrect voltage may permanently damage the unit.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eDedicated Power Circuit:\u003c\/strong\u003e Each actuator requires its own fuse-protected power supply. Do not connect multiple actuators in parallel.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eDisconnect Power Before Service:\u003c\/strong\u003e Always disconnect power before wiring, maintenance, or using the manual override.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eIP65 Weather Resistant:\u003c\/strong\u003e Suitable for outdoor use, but additional protection is recommended for permanent outdoor installations.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eLow Power Consumption:\u003c\/strong\u003e Power is only used during opening and closing. No power is consumed when fully open or fully closed.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eProfessional Installation Recommended:\u003c\/strong\u003e Installation should be performed by qualified personnel familiar with electrical control systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"font-size: 16px; line-height: 26px; font-family: Arial; color: black; margin-bottom: 20px;\"\u003e\n\u003cp style=\"margin-bottom: 10px;\"\u003e\u003cstrong\u003e1: Can I manually operate the valve?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px; padding-left: 15px;\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes. The actuator features a manual override. We recommend manually cycling the valve before installation to verify smooth operation, and using the adjustment screws during commissioning to fine-tune open\/close positions.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 10px;\"\u003e\u003cstrong\u003e2: Can this valve be installed outdoors?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px; padding-left: 15px;\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes, depending on your model's IP rating. While our heavy-duty actuators are weather-resistant, we highly recommend using a protective cover or shelter for permanent outdoor installations to shield the unit from direct UV rays and ice buildup.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 10px;\"\u003e\u003cstrong\u003e3: Is this valve suitable for high-viscosity fluids or particulates?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px; padding-left: 15px;\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes, but with torque considerations. Our heavy-duty series is built for high-torque applications. However, extremely viscous mediums or large particulates will increase resistance. Ensure the operating torque remains within the actuator's rated capacity to avoid stalling.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 10px;\"\u003e\u003cstrong\u003e4: Is it normal for the actuator to feel hot during operation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px; padding-left: 15px;\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes, it is normal to feel warm during continuous cycling. The actuator includes built-in power-limiting features to prevent overheating under normal use. If the housing becomes too hot to touch, please check that you are not exceeding the recommended duty cycle or the ambient temperature limit (-30°C to +60°C).\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 10px;\"\u003e\u003cstrong\u003e5: Can I wire multiple actuators in parallel on the same circuit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px; padding-left: 15px;\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e No. Each motorized actuator must be installed on its own dedicated, fuse-protected circuit to ensure proper signal response and prevent electrical interference or damage.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 16px; margin-top: 25px;\"\u003eDownload user manual \u003ca style=\"color: #0066cc; text-decoration: underline;\" rel=\"noopener\" href=\"http:\/\/file.ussolid.com\/content\/JFHDBV\/JFHDBV-%20Electric%20Actuated%20Ball%20Valve%20instruction%20manual.pdf\" target=\"_blank\"\u003ehere\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"font-family: Arial, sans-serif; color: black;\" class=\"mobile-only\"\u003e\n\u003ch3 style=\"margin-bottom: 20px; margin-top: 0;\"\u003e\u003cimg alt=\"Product Introduction\" style=\"width: 100%; max-width: 100%; height: auto; display: block;\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/%E6%9D%A1%E7%8A%B6%E5%9B%BE.jpg\"\u003e\u003c\/h3\u003e\n\u003cp style=\"font-size: 20px; font-family: Arial; text-align: left; margin-top: 0px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 15px; line-height: 24px; font-family: Arial; color: black; margin-bottom: 20px;\"\u003eThis premium flow control solution integrates a heavy-duty 3-piece stainless steel ball valve with a high-performance electric actuator. Engineered for reliability and precision, it provides a comprehensive hardware suite for automated systems, offering superior durability, seamless integration, and simplified maintenance in demanding industrial environments.\u003c\/p\u003e\n\u003cp style=\"font-size: 20px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"margin-bottom: 20px; text-align: center;\"\u003e\u003cimg alt=\"\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/FEATURES.webp\"\u003e\u003c\/div\u003e\n\u003cul style=\"font-size: 15px; line-height: 24px; color: black; font-family: Arial; margin-bottom: 20px; padding-left: 20px;\"\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003ePremium Material Construction:\u003c\/strong\u003e Crafted from high-grade 304 stainless steel, the valve body is highly resistant to corrosion, making it suitable for handling weak acids, weak alkalis, chemical solvents, and water.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eMaintenance-Friendly 3-Piece Design:\u003c\/strong\u003e The innovative 3-piece body construction allows for seamless in-line maintenance. Internal components can be easily cleaned or replaced without the need to disconnect the pipes, significantly reducing downtime and service costs.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eHigh-Pressure \u0026amp; Full-Bore Efficiency:\u003c\/strong\u003e Designed for maximum performance, the full-bore configuration guarantees minimal pressure drop, ensuring optimal flow capacity even in high-pressure systems.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eSmart Automation Ready:\u003c\/strong\u003e Equipped with integrated limit switches and position feedback, the actuator allows for seamless integration with PLC systems, enabling precise remote control, real-time monitoring, and full automation in complex industrial processes.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eHigh-Torque Reliability:\u003c\/strong\u003e Powered by a compact yet robust heavy-duty motor, the actuator delivers a steady torque of 50Nm, ensuring consistent full-port opening and reliable drop-tight sealing for every cycle.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eEnhanced Safety \u0026amp; Self-Locking:\u003c\/strong\u003e The actuator features an integrated self-locking mechanism to ensure valve stability and system integrity. Additionally, a built-in manual override port ensures safe, reliable intervention during power outages or emergencies.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eRugged Outdoor Durability:\u003c\/strong\u003e Engineered for the elements, the unit is encased in a powder-coated polyester aluminum housing, providing exceptional resistance to corrosion and harsh weather.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eAdvanced Circuitry Protection:\u003c\/strong\u003e To ensure long-term electrical reliability, the internal PCBA is treated with a protective sealant, effectively preventing damage from moisture, condensation, and short circuits.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size: 20px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px;\"\u003e\u003cimg alt=\"Applications\" style=\"width: 100%; max-width: 100%; height: auto; display: block;\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/Application.png\"\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 20px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eWIRING DIAGRAMS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; gap: 12px; margin-bottom: 20px;\"\u003e\n\u003cimg alt=\"Wiring Diagram 1\" style=\"width: 100%; max-width: 100%; height: auto; display: block;\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/Wiring-AB.jpg\"\u003e \u003cimg alt=\"Wiring Diagram 2\" style=\"width: 100%; max-width: 100%; height: auto; display: block;\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/Wiring-CD.jpg\"\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 20px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eELECTRIC WIRING\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; gap: 15px; margin-bottom: 20px;\"\u003e\n\u003cdiv style=\"width: 100%; text-align: center;\"\u003e\n\u003ch4 style=\"font-size: 15px; margin-top: 0; margin-bottom: 10px;\"\u003e\u003cstrong\u003e[OPEN]\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cimg style=\"width: 100%; max-width: 100%; height: auto;\" alt=\"OPEN\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/JFHDBV-OPEN.gif\"\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"width: 100%; text-align: center;\"\u003e\n\u003ch4 style=\"font-size: 15px; margin-top: 0; margin-bottom: 10px;\"\u003e\u003cstrong\u003e[CLOSED]\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cimg style=\"width: 100%; max-width: 100%; height: auto;\" alt=\"CLOSED\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/JFHDBV-CLOSED.gif\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 20px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"width: 100%; overflow-x: auto; margin-bottom: 20px;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; background-color: rgb(255, 255, 255); font-size: 15px; font-family: Arial; color: black; height: 425.521px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 22.3958px;\"\u003e\n\u003cth style=\"width: 20%; padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; text-align: center; height: 22.3958px;\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 6px; height: 22.3958px;\"\u003eUSS-HDBV00012\u003c\/td\u003e\n\u003cth style=\"width: 20%; padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; text-align: center; height: 22.3958px;\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 6px; height: 22.3958px;\"\u003eU.S. Solid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 44.7917px;\"\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eSize\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 44.7917px;\"\u003e3\/4\"\u003c\/td\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eWiring Type\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 44.7917px;\"\u003eType B: ON\/OFF Type, Dry Contact\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 44.7917px;\"\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eValve Material\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 44.7917px;\"\u003e304SS\u003c\/td\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eBall Seal\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 44.7917px;\"\u003ePTFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 44.7917px;\"\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eOperating Time\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 44.7917px;\"\u003e20 Seconds\u003c\/td\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eWorking Voltage\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 44.7917px;\"\u003e110V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 22.3958px;\"\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 22.3958px;\"\u003eMax Power\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 22.3958px;\"\u003e20 W\u003c\/td\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 22.3958px;\"\u003eMax Torque\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 22.3958px;\"\u003e50 N m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 89.5833px;\"\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 89.5833px;\"\u003eMax Medium Pressure\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 89.5833px;\"\u003e1.6 Mpa\u003c\/td\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 89.5833px;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 89.5833px;\"\u003e-30°C to 180°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 44.7917px;\"\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eLife Expectancy\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 44.7917px;\"\u003e30,000 to 50,000 Cycles\u003c\/td\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eBore Type\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 44.7917px;\"\u003eFull port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 44.7917px;\"\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eThread Type\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 44.7917px;\"\u003eNPT\u003c\/td\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eOperating State\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 44.7917px;\"\u003eRemain in position\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 67.1875px;\"\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 67.1875px;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 67.1875px;\"\u003e-30°C to 60°C\u003c\/td\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 67.1875px;\"\u003eEnclosure Rating\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 67.1875px;\"\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 20px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eWARNINGS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"font-size: 15px; line-height: 24px; color: black; font-family: Arial; margin-bottom: 20px; padding-left: 20px;\"\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003ePower Failure Behavior:\u003c\/strong\u003e This valve remains in its current position during a power outage. It does not automatically return to a preset position.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eVoltage Match Required:\u003c\/strong\u003e Supply voltage must match the actuator rating exactly. Incorrect voltage may permanently damage the unit.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eDedicated Power Circuit:\u003c\/strong\u003e Each actuator requires its own fuse-protected power supply. Do not connect multiple actuators in parallel.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eDisconnect Power Before Service:\u003c\/strong\u003e Always disconnect power before wiring, maintenance, or using the manual override.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eIP65 Weather Resistant:\u003c\/strong\u003e Suitable for outdoor use, but additional protection is recommended for permanent outdoor installations.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eLow Power Consumption:\u003c\/strong\u003e Power is only used during opening and closing. No power is consumed when fully open or fully closed.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eProfessional Installation Recommended:\u003c\/strong\u003e Installation should be performed by qualified personnel familiar with electrical control systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size: 20px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"font-size: 15px; line-height: 24px; font-family: Arial; color: black; margin-bottom: 20px;\"\u003e\n\u003cp style=\"margin-bottom: 10px;\"\u003e\u003cstrong\u003e1: Can I manually operate the valve?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px; padding-left: 15px;\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes. The actuator features a manual override. We recommend manually cycling the valve before installation to verify smooth operation, and using the adjustment screws during commissioning to fine-tune open\/close positions.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 10px;\"\u003e\u003cstrong\u003e2: Can this valve be installed outdoors?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px; padding-left: 15px;\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes, depending on your model's IP rating. While our heavy-duty actuators are weather-resistant, we highly recommend using a protective cover or shelter for permanent outdoor installations to shield the unit from direct UV rays and ice buildup.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 10px;\"\u003e\u003cstrong\u003e3: Is this valve suitable for high-viscosity fluids or particulates?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px; padding-left: 15px;\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes, but with torque considerations. Our heavy-duty series is built for high-torque applications. However, extremely viscous mediums or large particulates will increase resistance. Ensure the operating torque remains within the actuator's rated capacity to avoid stalling.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 10px;\"\u003e\u003cstrong\u003e4: Is it normal for the actuator to feel hot during operation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px; padding-left: 15px;\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes, it is normal to feel warm during continuous cycling. The actuator includes built-in power-limiting features to prevent overheating under normal use. If the housing becomes too hot to touch, please check that you are not exceeding the recommended duty cycle or the ambient temperature limit (-30°C to +60°C).\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 10px;\"\u003e\u003cstrong\u003e5: Can I wire multiple actuators in parallel on the same circuit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px; padding-left: 15px;\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e No. Each motorized actuator must be installed on its own dedicated, fuse-protected circuit to ensure proper signal response and prevent electrical interference or damage.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 15px; margin-top: 25px;\"\u003eDownload user manual \u003ca style=\"color: #0066cc; text-decoration: underline;\" rel=\"noopener\" href=\"http:\/\/file.ussolid.com\/content\/JFHDBV\/JFHDBV-%20Electric%20Actuated%20Ball%20Valve%20instruction%20manual.pdf\" target=\"_blank\"\u003ehere\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"U.S. Solid","offers":[{"title":"Default Title","offer_id":48293062508799,"sku":"JFHDBV00012","price":219.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/2_4547e780-18d0-49c9-839d-f5f237217c48.jpg?v=1778311525"},{"product_id":"1-electric-actuated-ball-valve-heavy-duty-3-piece-industrial-ball-valve-304ss","title":"1\" Electric Actuated Ball Valve, 110V AC Heavy Duty 3-Piece Industrial Ball Valve,304SS, ON\/OFF Type, Dry Contact","description":"\u003cstyle\u003e\n  .mobile-only {\n    display: none;\n  }\n\n  .desktop-only img,\n  .mobile-only img {\n    max-width: 100%;\n    height: auto;\n  }\n\n  @media only screen and (max-width: 600px) {\n    .desktop-only {\n      display: none !important;\n    }\n\n    .mobile-only {\n      display: block !important;\n      font-family: Arial, sans-serif;\n      color: black;\n    }\n\n    .mobile-only table {\n      min-width: 620px;\n    }\n\n    .mobile-only ul {\n      padding-left: 18px !important;\n    }\n  }\n\n  @media only screen and (min-width: 601px) {\n    .desktop-only {\n      display: block !important;\n    }\n\n    .mobile-only {\n      display: none !important;\n    }\n  }\n\u003c\/style\u003e\n\u003cdiv style=\"font-family: Arial, sans-serif; color: black;\" class=\"desktop-only\"\u003e\n\u003ch3 style=\"margin-bottom: 20px; margin-top: 0;\"\u003e\u003cimg alt=\"Product Introduction\" style=\"width: 100%; max-width: 100%; height: auto; display: block;\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/%E6%9D%A1%E7%8A%B6%E5%9B%BE.jpg\"\u003e\u003c\/h3\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top: 0px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; line-height: 26px; font-family: Arial; color: black; margin-bottom: 20px;\"\u003eThis premium flow control solution integrates a heavy-duty 3-piece stainless steel ball valve with a high-performance electric actuator. Engineered for reliability and precision, it provides a comprehensive hardware suite for automated systems, offering superior durability, seamless integration, and simplified maintenance in demanding industrial environments.\u003c\/p\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"margin-bottom: 20px; text-align: center;\"\u003e\u003cimg alt=\"\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/FEATURES.webp\"\u003e\u003c\/div\u003e\n\u003cul style=\"font-size: 16px; line-height: 26px; color: black; font-family: Arial; margin-bottom: 20px; padding-left: 20px;\"\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003ePremium Material Construction:\u003c\/strong\u003e Crafted from high-grade 304 stainless steel, the valve body is highly resistant to corrosion, making it suitable for handling weak acids, weak alkalis, chemical solvents, and water.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eMaintenance-Friendly 3-Piece Design:\u003c\/strong\u003e The innovative 3-piece body construction allows for seamless in-line maintenance. Internal components can be easily cleaned or replaced without the need to disconnect the pipes, significantly reducing downtime and service costs.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eHigh-Pressure \u0026amp; Full-Bore Efficiency:\u003c\/strong\u003e Designed for maximum performance, the full-bore configuration guarantees minimal pressure drop, ensuring optimal flow capacity even in high-pressure systems.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eSmart Automation Ready:\u003c\/strong\u003e Equipped with integrated limit switches and position feedback, the actuator allows for seamless integration with PLC systems, enabling precise remote control, real-time monitoring, and full automation in complex industrial processes.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eHigh-Torque Reliability:\u003c\/strong\u003e Powered by a compact yet robust heavy-duty motor, the actuator delivers a steady torque of 50Nm, ensuring consistent full-port opening and reliable drop-tight sealing for every cycle.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eEnhanced Safety \u0026amp; Self-Locking:\u003c\/strong\u003e The actuator features an integrated self-locking mechanism to ensure valve stability and system integrity. Additionally, a built-in manual override port ensures safe, reliable intervention during power outages or emergencies.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eRugged Outdoor Durability:\u003c\/strong\u003e Engineered for the elements, the unit is encased in a powder-coated polyester aluminum housing, providing exceptional resistance to corrosion and harsh weather.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eAdvanced Circuitry Protection:\u003c\/strong\u003e To ensure long-term electrical reliability, the internal PCBA is treated with a protective sealant, effectively preventing damage from moisture, condensation, and short circuits.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px;\"\u003e\u003cimg alt=\"Applications\" style=\"width: 100%; max-width: 100%; height: auto; display: block;\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/Application.png\"\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eWIRING DIAGRAMS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 15px; margin-bottom: 20px;\"\u003e\n\u003cimg alt=\"Wiring Diagram 1\" style=\"flex: 1; min-width: 280px; max-width: 100%; height: auto;\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/Wiring-AB.jpg\"\u003e \u003cimg alt=\"Wiring Diagram 2\" style=\"flex: 1; min-width: 280px; max-width: 100%; height: auto;\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/Wiring-CD.jpg\"\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eELECTRIC WIRING\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 20px; margin-bottom: 20px;\"\u003e\n\u003cdiv style=\"flex: 1; min-width: 280px; text-align: center;\"\u003e\n\u003ch4 style=\"font-size: 16px; margin-top: 0; margin-bottom: 10px;\"\u003e\u003cstrong\u003e[OPEN]\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cimg style=\"width: 100%; max-width: 450px; height: auto;\" alt=\"OPEN\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/JFHDBV-OPEN.gif\"\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; min-width: 280px; text-align: center;\"\u003e\n\u003ch4 style=\"font-size: 16px; margin-top: 0; margin-bottom: 10px;\"\u003e\u003cstrong\u003e[CLOSED]\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cimg style=\"width: 100%; max-width: 450px; height: auto;\" alt=\"CLOSED\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/JFHDBV-CLOSED.gif\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"width: 100%; overflow-x: auto; margin-bottom: 20px;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; background-color: rgb(255, 255, 255); font-size: 16px; font-family: Arial; color: black; height: 425.521px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 22.3958px;\"\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; text-align: center; height: 22.3958px;\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px; height: 22.3958px;\"\u003eUSS-HDBV00011\u003c\/td\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; text-align: center; height: 22.3958px;\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px; height: 22.3958px;\"\u003eU.S. Solid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 44.7917px;\"\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eSize\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 44.7917px;\"\u003e1\/2\"\u003c\/td\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eWiring Type\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 44.7917px;\"\u003eType B: ON\/OFF Type, Dry Contact\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 44.7917px;\"\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eValve Material\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 44.7917px;\"\u003e304SS\u003c\/td\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eBall Seal\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 44.7917px;\"\u003ePTFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 44.7917px;\"\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eOperating Time\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 44.7917px;\"\u003e20 Seconds\u003c\/td\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eWorking Voltage\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 44.7917px;\"\u003e110V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 22.3958px;\"\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 22.3958px;\"\u003eMax Power\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 22.3958px;\"\u003e20 W\u003c\/td\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 22.3958px;\"\u003eMax Torque\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 22.3958px;\"\u003e50 N m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 89.5833px;\"\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 89.5833px;\"\u003eMax Medium Pressure\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 89.5833px;\"\u003e1.6 Mpa\u003c\/td\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 89.5833px;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 89.5833px;\"\u003e-30°C to 180°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 44.7917px;\"\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eLife Expectancy\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 44.7917px;\"\u003e30,000 to 50,000 Cycles\u003c\/td\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eBore Type\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 44.7917px;\"\u003eFull port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 44.7917px;\"\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eThread Type\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 44.7917px;\"\u003eNPT\u003c\/td\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eOperating State\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 44.7917px;\"\u003eRemain in position\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 67.1875px;\"\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 67.1875px;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 67.1875px;\"\u003e-30°C to 60°C\u003c\/td\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 67.1875px;\"\u003eEnclosure Rating\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 67.1875px;\"\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eWARNINGS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"font-size: 16px; line-height: 26px; color: black; font-family: Arial; margin-bottom: 20px; padding-left: 20px;\"\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003ePower Failure Behavior:\u003c\/strong\u003e This valve remains in its current position during a power outage. It does not automatically return to a preset position.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eVoltage Match Required:\u003c\/strong\u003e Supply voltage must match the actuator rating exactly. Incorrect voltage may permanently damage the unit.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eDedicated Power Circuit:\u003c\/strong\u003e Each actuator requires its own fuse-protected power supply. Do not connect multiple actuators in parallel.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eDisconnect Power Before Service:\u003c\/strong\u003e Always disconnect power before wiring, maintenance, or using the manual override.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eIP65 Weather Resistant:\u003c\/strong\u003e Suitable for outdoor use, but additional protection is recommended for permanent outdoor installations.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eLow Power Consumption:\u003c\/strong\u003e Power is only used during opening and closing. No power is consumed when fully open or fully closed.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eProfessional Installation Recommended:\u003c\/strong\u003e Installation should be performed by qualified personnel familiar with electrical control systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"font-size: 16px; line-height: 26px; font-family: Arial; color: black; margin-bottom: 20px;\"\u003e\n\u003cp style=\"margin-bottom: 10px;\"\u003e\u003cstrong\u003e1: Can I manually operate the valve?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px; padding-left: 15px;\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes. The actuator features a manual override. We recommend manually cycling the valve before installation to verify smooth operation, and using the adjustment screws during commissioning to fine-tune open\/close positions.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 10px;\"\u003e\u003cstrong\u003e2: Can this valve be installed outdoors?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px; padding-left: 15px;\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes, depending on your model's IP rating. While our heavy-duty actuators are weather-resistant, we highly recommend using a protective cover or shelter for permanent outdoor installations to shield the unit from direct UV rays and ice buildup.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 10px;\"\u003e\u003cstrong\u003e3: Is this valve suitable for high-viscosity fluids or particulates?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px; padding-left: 15px;\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes, but with torque considerations. Our heavy-duty series is built for high-torque applications. However, extremely viscous mediums or large particulates will increase resistance. Ensure the operating torque remains within the actuator's rated capacity to avoid stalling.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 10px;\"\u003e\u003cstrong\u003e4: Is it normal for the actuator to feel hot during operation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px; padding-left: 15px;\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes, it is normal to feel warm during continuous cycling. The actuator includes built-in power-limiting features to prevent overheating under normal use. If the housing becomes too hot to touch, please check that you are not exceeding the recommended duty cycle or the ambient temperature limit (-30°C to +60°C).\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 10px;\"\u003e\u003cstrong\u003e5: Can I wire multiple actuators in parallel on the same circuit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px; padding-left: 15px;\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e No. Each motorized actuator must be installed on its own dedicated, fuse-protected circuit to ensure proper signal response and prevent electrical interference or damage.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 16px; margin-top: 25px;\"\u003eDownload user manual \u003ca style=\"color: #0066cc; text-decoration: underline;\" rel=\"noopener\" href=\"http:\/\/file.ussolid.com\/content\/JFHDBV\/JFHDBV-%20Electric%20Actuated%20Ball%20Valve%20instruction%20manual.pdf\" target=\"_blank\"\u003ehere\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"font-family: Arial, sans-serif; color: black;\" class=\"mobile-only\"\u003e\n\u003ch3 style=\"margin-bottom: 20px; margin-top: 0;\"\u003e\u003cimg alt=\"Product Introduction\" style=\"width: 100%; max-width: 100%; height: auto; display: block;\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/%E6%9D%A1%E7%8A%B6%E5%9B%BE.jpg\"\u003e\u003c\/h3\u003e\n\u003cp style=\"font-size: 20px; font-family: Arial; text-align: left; margin-top: 0px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 15px; line-height: 24px; font-family: Arial; color: black; margin-bottom: 20px;\"\u003eThis premium flow control solution integrates a heavy-duty 3-piece stainless steel ball valve with a high-performance electric actuator. Engineered for reliability and precision, it provides a comprehensive hardware suite for automated systems, offering superior durability, seamless integration, and simplified maintenance in demanding industrial environments.\u003c\/p\u003e\n\u003cp style=\"font-size: 20px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"margin-bottom: 20px; text-align: center;\"\u003e\u003cimg alt=\"\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/FEATURES.webp\"\u003e\u003c\/div\u003e\n\u003cul style=\"font-size: 15px; line-height: 24px; color: black; font-family: Arial; margin-bottom: 20px; padding-left: 20px;\"\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003ePremium Material Construction:\u003c\/strong\u003e Crafted from high-grade 304 stainless steel, the valve body is highly resistant to corrosion, making it suitable for handling weak acids, weak alkalis, chemical solvents, and water.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eMaintenance-Friendly 3-Piece Design:\u003c\/strong\u003e The innovative 3-piece body construction allows for seamless in-line maintenance. Internal components can be easily cleaned or replaced without the need to disconnect the pipes, significantly reducing downtime and service costs.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eHigh-Pressure \u0026amp; Full-Bore Efficiency:\u003c\/strong\u003e Designed for maximum performance, the full-bore configuration guarantees minimal pressure drop, ensuring optimal flow capacity even in high-pressure systems.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eSmart Automation Ready:\u003c\/strong\u003e Equipped with integrated limit switches and position feedback, the actuator allows for seamless integration with PLC systems, enabling precise remote control, real-time monitoring, and full automation in complex industrial processes.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eHigh-Torque Reliability:\u003c\/strong\u003e Powered by a compact yet robust heavy-duty motor, the actuator delivers a steady torque of 50Nm, ensuring consistent full-port opening and reliable drop-tight sealing for every cycle.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eEnhanced Safety \u0026amp; Self-Locking:\u003c\/strong\u003e The actuator features an integrated self-locking mechanism to ensure valve stability and system integrity. Additionally, a built-in manual override port ensures safe, reliable intervention during power outages or emergencies.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eRugged Outdoor Durability:\u003c\/strong\u003e Engineered for the elements, the unit is encased in a powder-coated polyester aluminum housing, providing exceptional resistance to corrosion and harsh weather.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eAdvanced Circuitry Protection:\u003c\/strong\u003e To ensure long-term electrical reliability, the internal PCBA is treated with a protective sealant, effectively preventing damage from moisture, condensation, and short circuits.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size: 20px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px;\"\u003e\u003cimg alt=\"Applications\" style=\"width: 100%; max-width: 100%; height: auto; display: block;\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/Application.png\"\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 20px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eWIRING DIAGRAMS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; gap: 12px; margin-bottom: 20px;\"\u003e\n\u003cimg alt=\"Wiring Diagram 1\" style=\"width: 100%; max-width: 100%; height: auto; display: block;\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/Wiring-AB.jpg\"\u003e \u003cimg alt=\"Wiring Diagram 2\" style=\"width: 100%; max-width: 100%; height: auto; display: block;\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/Wiring-CD.jpg\"\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 20px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eELECTRIC WIRING\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; gap: 15px; margin-bottom: 20px;\"\u003e\n\u003cdiv style=\"width: 100%; text-align: center;\"\u003e\n\u003ch4 style=\"font-size: 15px; margin-top: 0; margin-bottom: 10px;\"\u003e\u003cstrong\u003e[OPEN]\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cimg style=\"width: 100%; max-width: 100%; height: auto;\" alt=\"OPEN\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/JFHDBV-OPEN.gif\"\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"width: 100%; text-align: center;\"\u003e\n\u003ch4 style=\"font-size: 15px; margin-top: 0; margin-bottom: 10px;\"\u003e\u003cstrong\u003e[CLOSED]\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cimg style=\"width: 100%; max-width: 100%; height: auto;\" alt=\"CLOSED\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/JFHDBV-CLOSED.gif\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 20px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"width: 100%; overflow-x: auto; margin-bottom: 20px;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; background-color: rgb(255, 255, 255); font-size: 15px; font-family: Arial; color: black; height: 425.521px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 22.3958px;\"\u003e\n\u003cth style=\"width: 20%; padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; text-align: center; height: 22.3958px;\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 6px; height: 22.3958px;\"\u003eUSS-HDBV00013\u003c\/td\u003e\n\u003cth style=\"width: 20%; padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; text-align: center; height: 22.3958px;\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 6px; height: 22.3958px;\"\u003eU.S. Solid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 44.7917px;\"\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eSize\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 44.7917px;\"\u003e1\"\u003c\/td\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eWiring Type\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 44.7917px;\"\u003eType B: ON\/OFF Type, Dry Contact\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 44.7917px;\"\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eValve Material\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 44.7917px;\"\u003e304SS\u003c\/td\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eBall Seal\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 44.7917px;\"\u003ePTFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 44.7917px;\"\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eOperating Time\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 44.7917px;\"\u003e20 Seconds\u003c\/td\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eWorking Voltage\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 44.7917px;\"\u003e110V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 22.3958px;\"\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 22.3958px;\"\u003eMax Power\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 22.3958px;\"\u003e20 W\u003c\/td\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 22.3958px;\"\u003eMax Torque\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 22.3958px;\"\u003e50 N m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 89.5833px;\"\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 89.5833px;\"\u003eMax Medium Pressure\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 89.5833px;\"\u003e1.6 Mpa\u003c\/td\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 89.5833px;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 89.5833px;\"\u003e-30°C to 180°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 44.7917px;\"\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eLife Expectancy\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 44.7917px;\"\u003e30,000 to 50,000 Cycles\u003c\/td\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eBore Type\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 44.7917px;\"\u003eFull port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 44.7917px;\"\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eThread Type\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 44.7917px;\"\u003eNPT\u003c\/td\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eOperating State\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 44.7917px;\"\u003eRemain in position\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 67.1875px;\"\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 67.1875px;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 67.1875px;\"\u003e-30°C to 60°C\u003c\/td\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 67.1875px;\"\u003eEnclosure Rating\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 67.1875px;\"\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 20px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eWARNINGS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"font-size: 15px; line-height: 24px; color: black; font-family: Arial; margin-bottom: 20px; padding-left: 20px;\"\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003ePower Failure Behavior:\u003c\/strong\u003e This valve remains in its current position during a power outage. It does not automatically return to a preset position.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eVoltage Match Required:\u003c\/strong\u003e Supply voltage must match the actuator rating exactly. Incorrect voltage may permanently damage the unit.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eDedicated Power Circuit:\u003c\/strong\u003e Each actuator requires its own fuse-protected power supply. Do not connect multiple actuators in parallel.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eDisconnect Power Before Service:\u003c\/strong\u003e Always disconnect power before wiring, maintenance, or using the manual override.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eIP65 Weather Resistant:\u003c\/strong\u003e Suitable for outdoor use, but additional protection is recommended for permanent outdoor installations.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eLow Power Consumption:\u003c\/strong\u003e Power is only used during opening and closing. No power is consumed when fully open or fully closed.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eProfessional Installation Recommended:\u003c\/strong\u003e Installation should be performed by qualified personnel familiar with electrical control systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size: 20px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"font-size: 15px; line-height: 24px; font-family: Arial; color: black; margin-bottom: 20px;\"\u003e\n\u003cp style=\"margin-bottom: 10px;\"\u003e\u003cstrong\u003e1: Can I manually operate the valve?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px; padding-left: 15px;\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes. The actuator features a manual override. We recommend manually cycling the valve before installation to verify smooth operation, and using the adjustment screws during commissioning to fine-tune open\/close positions.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 10px;\"\u003e\u003cstrong\u003e2: Can this valve be installed outdoors?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px; padding-left: 15px;\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes, depending on your model's IP rating. While our heavy-duty actuators are weather-resistant, we highly recommend using a protective cover or shelter for permanent outdoor installations to shield the unit from direct UV rays and ice buildup.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 10px;\"\u003e\u003cstrong\u003e3: Is this valve suitable for high-viscosity fluids or particulates?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px; padding-left: 15px;\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes, but with torque considerations. Our heavy-duty series is built for high-torque applications. However, extremely viscous mediums or large particulates will increase resistance. Ensure the operating torque remains within the actuator's rated capacity to avoid stalling.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 10px;\"\u003e\u003cstrong\u003e4: Is it normal for the actuator to feel hot during operation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px; padding-left: 15px;\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes, it is normal to feel warm during continuous cycling. The actuator includes built-in power-limiting features to prevent overheating under normal use. If the housing becomes too hot to touch, please check that you are not exceeding the recommended duty cycle or the ambient temperature limit (-30°C to +60°C).\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 10px;\"\u003e\u003cstrong\u003e5: Can I wire multiple actuators in parallel on the same circuit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px; padding-left: 15px;\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e No. Each motorized actuator must be installed on its own dedicated, fuse-protected circuit to ensure proper signal response and prevent electrical interference or damage.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 15px; margin-top: 25px;\"\u003eDownload user manual \u003ca style=\"color: #0066cc; text-decoration: underline;\" rel=\"noopener\" href=\"http:\/\/file.ussolid.com\/content\/JFHDBV\/JFHDBV-%20Electric%20Actuated%20Ball%20Valve%20instruction%20manual.pdf\" target=\"_blank\"\u003ehere\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"U.S. Solid","offers":[{"title":"Default Title","offer_id":48293064016127,"sku":"JFHDBV00013","price":249.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/2_9e46fbdb-b336-447e-950c-956a8b771403.jpg?v=1778312036"},{"product_id":"1-1-4-electric-actuated-ball-valve-heavy-duty-3-piece-industrial-ball-valve-304ss","title":"1 1\/4\" Electric Actuated Ball Valve, 110V AC Heavy Duty 3-Piece Industrial Ball Valve,304SS, ON\/OFF Type, Dry Contact","description":"\u003cstyle\u003e\n  .mobile-only {\n    display: none;\n  }\n\n  .desktop-only img,\n  .mobile-only img {\n    max-width: 100%;\n    height: auto;\n  }\n\n  @media only screen and (max-width: 600px) {\n    .desktop-only {\n      display: none !important;\n    }\n\n    .mobile-only {\n      display: block !important;\n      font-family: Arial, sans-serif;\n      color: black;\n    }\n\n    .mobile-only table {\n      min-width: 620px;\n    }\n\n    .mobile-only ul {\n      padding-left: 18px !important;\n    }\n  }\n\n  @media only screen and (min-width: 601px) {\n    .desktop-only {\n      display: block !important;\n    }\n\n    .mobile-only {\n      display: none !important;\n    }\n  }\n\u003c\/style\u003e\n\u003cdiv style=\"font-family: Arial, sans-serif; color: black;\" class=\"desktop-only\"\u003e\n\u003ch3 style=\"margin-bottom: 20px; margin-top: 0;\"\u003e\u003cimg alt=\"Product Introduction\" style=\"width: 100%; max-width: 100%; height: auto; display: block;\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/%E6%9D%A1%E7%8A%B6%E5%9B%BE.jpg\"\u003e\u003c\/h3\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top: 0px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; line-height: 26px; font-family: Arial; color: black; margin-bottom: 20px;\"\u003eThis premium flow control solution integrates a heavy-duty 3-piece stainless steel ball valve with a high-performance electric actuator. Engineered for reliability and precision, it provides a comprehensive hardware suite for automated systems, offering superior durability, seamless integration, and simplified maintenance in demanding industrial environments.\u003c\/p\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"margin-bottom: 20px; text-align: center;\"\u003e\u003cimg alt=\"\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/FEATURES.webp\"\u003e\u003c\/div\u003e\n\u003cul style=\"font-size: 16px; line-height: 26px; color: black; font-family: Arial; margin-bottom: 20px; padding-left: 20px;\"\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003ePremium Material Construction:\u003c\/strong\u003e Crafted from high-grade 304 stainless steel, the valve body is highly resistant to corrosion, making it suitable for handling weak acids, weak alkalis, chemical solvents, and water.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eMaintenance-Friendly 3-Piece Design:\u003c\/strong\u003e The innovative 3-piece body construction allows for seamless in-line maintenance. Internal components can be easily cleaned or replaced without the need to disconnect the pipes, significantly reducing downtime and service costs.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eHigh-Pressure \u0026amp; Full-Bore Efficiency:\u003c\/strong\u003e Designed for maximum performance, the full-bore configuration guarantees minimal pressure drop, ensuring optimal flow capacity even in high-pressure systems.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eSmart Automation Ready:\u003c\/strong\u003e Equipped with integrated limit switches and position feedback, the actuator allows for seamless integration with PLC systems, enabling precise remote control, real-time monitoring, and full automation in complex industrial processes.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eHigh-Torque Reliability:\u003c\/strong\u003e Powered by a compact yet robust heavy-duty motor, the actuator delivers a steady torque of 50Nm, ensuring consistent full-port opening and reliable drop-tight sealing for every cycle.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eEnhanced Safety \u0026amp; Self-Locking:\u003c\/strong\u003e The actuator features an integrated self-locking mechanism to ensure valve stability and system integrity. Additionally, a built-in manual override port ensures safe, reliable intervention during power outages or emergencies.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eRugged Outdoor Durability:\u003c\/strong\u003e Engineered for the elements, the unit is encased in a powder-coated polyester aluminum housing, providing exceptional resistance to corrosion and harsh weather.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eAdvanced Circuitry Protection:\u003c\/strong\u003e To ensure long-term electrical reliability, the internal PCBA is treated with a protective sealant, effectively preventing damage from moisture, condensation, and short circuits.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px;\"\u003e\u003cimg alt=\"Applications\" style=\"width: 100%; max-width: 100%; height: auto; display: block;\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/Application.png\"\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eWIRING DIAGRAMS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 15px; margin-bottom: 20px;\"\u003e\n\u003cimg alt=\"Wiring Diagram 1\" style=\"flex: 1; min-width: 280px; max-width: 100%; height: auto;\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/Wiring-AB.jpg\"\u003e \u003cimg alt=\"Wiring Diagram 2\" style=\"flex: 1; min-width: 280px; max-width: 100%; height: auto;\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/Wiring-CD.jpg\"\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eELECTRIC WIRING\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 20px; margin-bottom: 20px;\"\u003e\n\u003cdiv style=\"flex: 1; min-width: 280px; text-align: center;\"\u003e\n\u003ch4 style=\"font-size: 16px; margin-top: 0; margin-bottom: 10px;\"\u003e\u003cstrong\u003e[OPEN]\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cimg style=\"width: 100%; max-width: 450px; height: auto;\" alt=\"OPEN\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/JFHDBV-OPEN.gif\"\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; min-width: 280px; text-align: center;\"\u003e\n\u003ch4 style=\"font-size: 16px; margin-top: 0; margin-bottom: 10px;\"\u003e\u003cstrong\u003e[CLOSED]\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cimg style=\"width: 100%; max-width: 450px; height: auto;\" alt=\"CLOSED\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/JFHDBV-CLOSED.gif\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"width: 100%; overflow-x: auto; margin-bottom: 20px;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; background-color: rgb(255, 255, 255); font-size: 16px; font-family: Arial; color: black; height: 425.521px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 22.3958px;\"\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; text-align: center; height: 22.3958px;\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px; height: 22.3958px;\"\u003eUSS-HDBV00011\u003c\/td\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; text-align: center; height: 22.3958px;\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px; height: 22.3958px;\"\u003eU.S. Solid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 44.7917px;\"\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eSize\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 44.7917px;\"\u003e1\/2\"\u003c\/td\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eWiring Type\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 44.7917px;\"\u003eType B: ON\/OFF Type, Dry Contact\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 44.7917px;\"\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eValve Material\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 44.7917px;\"\u003e304SS\u003c\/td\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eBall Seal\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 44.7917px;\"\u003ePTFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 44.7917px;\"\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eOperating Time\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 44.7917px;\"\u003e20 Seconds\u003c\/td\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eWorking Voltage\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 44.7917px;\"\u003e110V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 22.3958px;\"\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 22.3958px;\"\u003eMax Power\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 22.3958px;\"\u003e20 W\u003c\/td\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 22.3958px;\"\u003eMax Torque\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 22.3958px;\"\u003e50 N m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 89.5833px;\"\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 89.5833px;\"\u003eMax Medium Pressure\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 89.5833px;\"\u003e1.6 Mpa\u003c\/td\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 89.5833px;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 89.5833px;\"\u003e-30°C to 180°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 44.7917px;\"\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eLife Expectancy\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 44.7917px;\"\u003e30,000 to 50,000 Cycles\u003c\/td\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eBore Type\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 44.7917px;\"\u003eFull port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 44.7917px;\"\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eThread Type\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 44.7917px;\"\u003eNPT\u003c\/td\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eOperating State\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 44.7917px;\"\u003eRemain in position\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 67.1875px;\"\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 67.1875px;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 67.1875px;\"\u003e-30°C to 60°C\u003c\/td\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 67.1875px;\"\u003eEnclosure Rating\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 67.1875px;\"\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eWARNINGS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"font-size: 16px; line-height: 26px; color: black; font-family: Arial; margin-bottom: 20px; padding-left: 20px;\"\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003ePower Failure Behavior:\u003c\/strong\u003e This valve remains in its current position during a power outage. It does not automatically return to a preset position.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eVoltage Match Required:\u003c\/strong\u003e Supply voltage must match the actuator rating exactly. Incorrect voltage may permanently damage the unit.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eDedicated Power Circuit:\u003c\/strong\u003e Each actuator requires its own fuse-protected power supply. Do not connect multiple actuators in parallel.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eDisconnect Power Before Service:\u003c\/strong\u003e Always disconnect power before wiring, maintenance, or using the manual override.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eIP65 Weather Resistant:\u003c\/strong\u003e Suitable for outdoor use, but additional protection is recommended for permanent outdoor installations.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eLow Power Consumption:\u003c\/strong\u003e Power is only used during opening and closing. No power is consumed when fully open or fully closed.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eProfessional Installation Recommended:\u003c\/strong\u003e Installation should be performed by qualified personnel familiar with electrical control systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"font-size: 16px; line-height: 26px; font-family: Arial; color: black; margin-bottom: 20px;\"\u003e\n\u003cp style=\"margin-bottom: 10px;\"\u003e\u003cstrong\u003e1: Can I manually operate the valve?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px; padding-left: 15px;\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes. The actuator features a manual override. We recommend manually cycling the valve before installation to verify smooth operation, and using the adjustment screws during commissioning to fine-tune open\/close positions.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 10px;\"\u003e\u003cstrong\u003e2: Can this valve be installed outdoors?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px; padding-left: 15px;\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes, depending on your model's IP rating. While our heavy-duty actuators are weather-resistant, we highly recommend using a protective cover or shelter for permanent outdoor installations to shield the unit from direct UV rays and ice buildup.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 10px;\"\u003e\u003cstrong\u003e3: Is this valve suitable for high-viscosity fluids or particulates?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px; padding-left: 15px;\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes, but with torque considerations. Our heavy-duty series is built for high-torque applications. However, extremely viscous mediums or large particulates will increase resistance. Ensure the operating torque remains within the actuator's rated capacity to avoid stalling.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 10px;\"\u003e\u003cstrong\u003e4: Is it normal for the actuator to feel hot during operation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px; padding-left: 15px;\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes, it is normal to feel warm during continuous cycling. The actuator includes built-in power-limiting features to prevent overheating under normal use. If the housing becomes too hot to touch, please check that you are not exceeding the recommended duty cycle or the ambient temperature limit (-30°C to +60°C).\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 10px;\"\u003e\u003cstrong\u003e5: Can I wire multiple actuators in parallel on the same circuit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px; padding-left: 15px;\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e No. Each motorized actuator must be installed on its own dedicated, fuse-protected circuit to ensure proper signal response and prevent electrical interference or damage.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 16px; margin-top: 25px;\"\u003eDownload user manual \u003ca style=\"color: #0066cc; text-decoration: underline;\" rel=\"noopener\" href=\"http:\/\/file.ussolid.com\/content\/JFHDBV\/JFHDBV-%20Electric%20Actuated%20Ball%20Valve%20instruction%20manual.pdf\" target=\"_blank\"\u003ehere\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"font-family: Arial, sans-serif; color: black;\" class=\"mobile-only\"\u003e\n\u003ch3 style=\"margin-bottom: 20px; margin-top: 0;\"\u003e\u003cimg alt=\"Product Introduction\" style=\"width: 100%; max-width: 100%; height: auto; display: block;\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/%E6%9D%A1%E7%8A%B6%E5%9B%BE.jpg\"\u003e\u003c\/h3\u003e\n\u003cp style=\"font-size: 20px; font-family: Arial; text-align: left; margin-top: 0px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 15px; line-height: 24px; font-family: Arial; color: black; margin-bottom: 20px;\"\u003eThis premium flow control solution integrates a heavy-duty 3-piece stainless steel ball valve with a high-performance electric actuator. Engineered for reliability and precision, it provides a comprehensive hardware suite for automated systems, offering superior durability, seamless integration, and simplified maintenance in demanding industrial environments.\u003c\/p\u003e\n\u003cp style=\"font-size: 20px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"margin-bottom: 20px; text-align: center;\"\u003e\u003cimg alt=\"\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/FEATURES.webp\"\u003e\u003c\/div\u003e\n\u003cul style=\"font-size: 15px; line-height: 24px; color: black; font-family: Arial; margin-bottom: 20px; padding-left: 20px;\"\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003ePremium Material Construction:\u003c\/strong\u003e Crafted from high-grade 304 stainless steel, the valve body is highly resistant to corrosion, making it suitable for handling weak acids, weak alkalis, chemical solvents, and water.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eMaintenance-Friendly 3-Piece Design:\u003c\/strong\u003e The innovative 3-piece body construction allows for seamless in-line maintenance. Internal components can be easily cleaned or replaced without the need to disconnect the pipes, significantly reducing downtime and service costs.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eHigh-Pressure \u0026amp; Full-Bore Efficiency:\u003c\/strong\u003e Designed for maximum performance, the full-bore configuration guarantees minimal pressure drop, ensuring optimal flow capacity even in high-pressure systems.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eSmart Automation Ready:\u003c\/strong\u003e Equipped with integrated limit switches and position feedback, the actuator allows for seamless integration with PLC systems, enabling precise remote control, real-time monitoring, and full automation in complex industrial processes.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eHigh-Torque Reliability:\u003c\/strong\u003e Powered by a compact yet robust heavy-duty motor, the actuator delivers a steady torque of 50Nm, ensuring consistent full-port opening and reliable drop-tight sealing for every cycle.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eEnhanced Safety \u0026amp; Self-Locking:\u003c\/strong\u003e The actuator features an integrated self-locking mechanism to ensure valve stability and system integrity. Additionally, a built-in manual override port ensures safe, reliable intervention during power outages or emergencies.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eRugged Outdoor Durability:\u003c\/strong\u003e Engineered for the elements, the unit is encased in a powder-coated polyester aluminum housing, providing exceptional resistance to corrosion and harsh weather.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eAdvanced Circuitry Protection:\u003c\/strong\u003e To ensure long-term electrical reliability, the internal PCBA is treated with a protective sealant, effectively preventing damage from moisture, condensation, and short circuits.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size: 20px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px;\"\u003e\u003cimg alt=\"Applications\" style=\"width: 100%; max-width: 100%; height: auto; display: block;\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/Application.png\"\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 20px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eWIRING DIAGRAMS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; gap: 12px; margin-bottom: 20px;\"\u003e\n\u003cimg alt=\"Wiring Diagram 1\" style=\"width: 100%; max-width: 100%; height: auto; display: block;\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/Wiring-AB.jpg\"\u003e \u003cimg alt=\"Wiring Diagram 2\" style=\"width: 100%; max-width: 100%; height: auto; display: block;\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/Wiring-CD.jpg\"\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 20px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eELECTRIC WIRING\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; gap: 15px; margin-bottom: 20px;\"\u003e\n\u003cdiv style=\"width: 100%; text-align: center;\"\u003e\n\u003ch4 style=\"font-size: 15px; margin-top: 0; margin-bottom: 10px;\"\u003e\u003cstrong\u003e[OPEN]\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cimg style=\"width: 100%; max-width: 100%; height: auto;\" alt=\"OPEN\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/JFHDBV-OPEN.gif\"\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"width: 100%; text-align: center;\"\u003e\n\u003ch4 style=\"font-size: 15px; margin-top: 0; margin-bottom: 10px;\"\u003e\u003cstrong\u003e[CLOSED]\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cimg style=\"width: 100%; max-width: 100%; height: auto;\" alt=\"CLOSED\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/JFHDBV-CLOSED.gif\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 20px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"width: 100%; overflow-x: auto; margin-bottom: 20px;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; background-color: rgb(255, 255, 255); font-size: 15px; font-family: Arial; color: black; height: 425.521px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 22.3958px;\"\u003e\n\u003cth style=\"width: 20%; padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; text-align: center; height: 22.3958px;\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 6px; height: 22.3958px;\"\u003eUSS-HDBV00014\u003c\/td\u003e\n\u003cth style=\"width: 20%; padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; text-align: center; height: 22.3958px;\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 6px; height: 22.3958px;\"\u003eU.S. Solid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 44.7917px;\"\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eSize\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 44.7917px;\"\u003e1 1\/4\"\u003c\/td\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eWiring Type\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 44.7917px;\"\u003eType B: ON\/OFF Type, Dry Contact\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 44.7917px;\"\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eValve Material\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 44.7917px;\"\u003e304SS\u003c\/td\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eBall Seal\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 44.7917px;\"\u003ePTFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 44.7917px;\"\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eOperating Time\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 44.7917px;\"\u003e20 Seconds\u003c\/td\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eWorking Voltage\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 44.7917px;\"\u003e110V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 22.3958px;\"\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 22.3958px;\"\u003eMax Power\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 22.3958px;\"\u003e20 W\u003c\/td\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 22.3958px;\"\u003eMax Torque\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 22.3958px;\"\u003e50 N m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 89.5833px;\"\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 89.5833px;\"\u003eMax Medium Pressure\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 89.5833px;\"\u003e1.6 Mpa\u003c\/td\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 89.5833px;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 89.5833px;\"\u003e-30°C to 180°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 44.7917px;\"\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eLife Expectancy\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 44.7917px;\"\u003e30,000 to 50,000 Cycles\u003c\/td\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eBore Type\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 44.7917px;\"\u003eFull port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 44.7917px;\"\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eThread Type\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 44.7917px;\"\u003eNPT\u003c\/td\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eOperating State\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 44.7917px;\"\u003eRemain in position\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 67.1875px;\"\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 67.1875px;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 67.1875px;\"\u003e-30°C to 60°C\u003c\/td\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 67.1875px;\"\u003eEnclosure Rating\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 67.1875px;\"\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 20px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eWARNINGS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"font-size: 15px; line-height: 24px; color: black; font-family: Arial; margin-bottom: 20px; padding-left: 20px;\"\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003ePower Failure Behavior:\u003c\/strong\u003e This valve remains in its current position during a power outage. It does not automatically return to a preset position.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eVoltage Match Required:\u003c\/strong\u003e Supply voltage must match the actuator rating exactly. Incorrect voltage may permanently damage the unit.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eDedicated Power Circuit:\u003c\/strong\u003e Each actuator requires its own fuse-protected power supply. Do not connect multiple actuators in parallel.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eDisconnect Power Before Service:\u003c\/strong\u003e Always disconnect power before wiring, maintenance, or using the manual override.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eIP65 Weather Resistant:\u003c\/strong\u003e Suitable for outdoor use, but additional protection is recommended for permanent outdoor installations.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eLow Power Consumption:\u003c\/strong\u003e Power is only used during opening and closing. No power is consumed when fully open or fully closed.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eProfessional Installation Recommended:\u003c\/strong\u003e Installation should be performed by qualified personnel familiar with electrical control systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size: 20px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"font-size: 15px; line-height: 24px; font-family: Arial; color: black; margin-bottom: 20px;\"\u003e\n\u003cp style=\"margin-bottom: 10px;\"\u003e\u003cstrong\u003e1: Can I manually operate the valve?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px; padding-left: 15px;\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes. The actuator features a manual override. We recommend manually cycling the valve before installation to verify smooth operation, and using the adjustment screws during commissioning to fine-tune open\/close positions.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 10px;\"\u003e\u003cstrong\u003e2: Can this valve be installed outdoors?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px; padding-left: 15px;\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes, depending on your model's IP rating. While our heavy-duty actuators are weather-resistant, we highly recommend using a protective cover or shelter for permanent outdoor installations to shield the unit from direct UV rays and ice buildup.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 10px;\"\u003e\u003cstrong\u003e3: Is this valve suitable for high-viscosity fluids or particulates?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px; padding-left: 15px;\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes, but with torque considerations. Our heavy-duty series is built for high-torque applications. However, extremely viscous mediums or large particulates will increase resistance. Ensure the operating torque remains within the actuator's rated capacity to avoid stalling.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 10px;\"\u003e\u003cstrong\u003e4: Is it normal for the actuator to feel hot during operation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px; padding-left: 15px;\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes, it is normal to feel warm during continuous cycling. The actuator includes built-in power-limiting features to prevent overheating under normal use. If the housing becomes too hot to touch, please check that you are not exceeding the recommended duty cycle or the ambient temperature limit (-30°C to +60°C).\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 10px;\"\u003e\u003cstrong\u003e5: Can I wire multiple actuators in parallel on the same circuit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px; padding-left: 15px;\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e No. Each motorized actuator must be installed on its own dedicated, fuse-protected circuit to ensure proper signal response and prevent electrical interference or damage.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 15px; margin-top: 25px;\"\u003eDownload user manual \u003ca style=\"color: #0066cc; text-decoration: underline;\" rel=\"noopener\" href=\"http:\/\/file.ussolid.com\/content\/JFHDBV\/JFHDBV-%20Electric%20Actuated%20Ball%20Valve%20instruction%20manual.pdf\" target=\"_blank\"\u003ehere\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"U.S. Solid","offers":[{"title":"Default Title","offer_id":48293065818367,"sku":"JFHDBV00014","price":259.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/1_82ed4319-d78a-4cd0-98eb-202e06a44788.jpg?v=1778312794"},{"product_id":"1-1-2-electric-actuated-ball-valve-heavy-duty-3-piece-industrial-ball-valve-304ss","title":"1 1\/2\" Electric Actuated Ball Valve, 110V AC Heavy Duty 3-Piece Industrial Ball Valve,304SS, ON\/OFF Type, Dry Contact","description":"\u003cstyle\u003e\n  .mobile-only {\n    display: none;\n  }\n\n  .desktop-only img,\n  .mobile-only img {\n    max-width: 100%;\n    height: auto;\n  }\n\n  @media only screen and (max-width: 600px) {\n    .desktop-only {\n      display: none !important;\n    }\n\n    .mobile-only {\n      display: block !important;\n      font-family: Arial, sans-serif;\n      color: black;\n    }\n\n    .mobile-only table {\n      min-width: 620px;\n    }\n\n    .mobile-only ul {\n      padding-left: 18px !important;\n    }\n  }\n\n  @media only screen and (min-width: 601px) {\n    .desktop-only {\n      display: block !important;\n    }\n\n    .mobile-only {\n      display: none !important;\n    }\n  }\n\u003c\/style\u003e\n\u003cdiv style=\"font-family: Arial, sans-serif; color: black;\" class=\"desktop-only\"\u003e\n\u003ch3 style=\"margin-bottom: 20px; margin-top: 0;\"\u003e\u003cimg alt=\"Product Introduction\" style=\"width: 100%; max-width: 100%; height: auto; display: block;\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/%E6%9D%A1%E7%8A%B6%E5%9B%BE.jpg\"\u003e\u003c\/h3\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top: 0px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; line-height: 26px; font-family: Arial; color: black; margin-bottom: 20px;\"\u003eThis premium flow control solution integrates a heavy-duty 3-piece stainless steel ball valve with a high-performance electric actuator. Engineered for reliability and precision, it provides a comprehensive hardware suite for automated systems, offering superior durability, seamless integration, and simplified maintenance in demanding industrial environments.\u003c\/p\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"margin-bottom: 20px; text-align: center;\"\u003e\u003cimg alt=\"\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/FEATURES.webp\"\u003e\u003c\/div\u003e\n\u003cul style=\"font-size: 16px; line-height: 26px; color: black; font-family: Arial; margin-bottom: 20px; padding-left: 20px;\"\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003ePremium Material Construction:\u003c\/strong\u003e Crafted from high-grade 304 stainless steel, the valve body is highly resistant to corrosion, making it suitable for handling weak acids, weak alkalis, chemical solvents, and water.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eMaintenance-Friendly 3-Piece Design:\u003c\/strong\u003e The innovative 3-piece body construction allows for seamless in-line maintenance. Internal components can be easily cleaned or replaced without the need to disconnect the pipes, significantly reducing downtime and service costs.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eHigh-Pressure \u0026amp; Full-Bore Efficiency:\u003c\/strong\u003e Designed for maximum performance, the full-bore configuration guarantees minimal pressure drop, ensuring optimal flow capacity even in high-pressure systems.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eSmart Automation Ready:\u003c\/strong\u003e Equipped with integrated limit switches and position feedback, the actuator allows for seamless integration with PLC systems, enabling precise remote control, real-time monitoring, and full automation in complex industrial processes.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eHigh-Torque Reliability:\u003c\/strong\u003e Powered by a compact yet robust heavy-duty motor, the actuator delivers a steady torque of 50Nm, ensuring consistent full-port opening and reliable drop-tight sealing for every cycle.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eEnhanced Safety \u0026amp; Self-Locking:\u003c\/strong\u003e The actuator features an integrated self-locking mechanism to ensure valve stability and system integrity. Additionally, a built-in manual override port ensures safe, reliable intervention during power outages or emergencies.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eRugged Outdoor Durability:\u003c\/strong\u003e Engineered for the elements, the unit is encased in a powder-coated polyester aluminum housing, providing exceptional resistance to corrosion and harsh weather.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eAdvanced Circuitry Protection:\u003c\/strong\u003e To ensure long-term electrical reliability, the internal PCBA is treated with a protective sealant, effectively preventing damage from moisture, condensation, and short circuits.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px;\"\u003e\u003cimg alt=\"Applications\" style=\"width: 100%; max-width: 100%; height: auto; display: block;\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/Application.png\"\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eWIRING DIAGRAMS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 15px; margin-bottom: 20px;\"\u003e\n\u003cimg alt=\"Wiring Diagram 1\" style=\"flex: 1; min-width: 280px; max-width: 100%; height: auto;\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/Wiring-AB.jpg\"\u003e \u003cimg alt=\"Wiring Diagram 2\" style=\"flex: 1; min-width: 280px; max-width: 100%; height: auto;\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/Wiring-CD.jpg\"\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eELECTRIC WIRING\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 20px; margin-bottom: 20px;\"\u003e\n\u003cdiv style=\"flex: 1; min-width: 280px; text-align: center;\"\u003e\n\u003ch4 style=\"font-size: 16px; margin-top: 0; margin-bottom: 10px;\"\u003e\u003cstrong\u003e[OPEN]\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cimg style=\"width: 100%; max-width: 450px; height: auto;\" alt=\"OPEN\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/JFHDBV-OPEN.gif\"\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; min-width: 280px; text-align: center;\"\u003e\n\u003ch4 style=\"font-size: 16px; margin-top: 0; margin-bottom: 10px;\"\u003e\u003cstrong\u003e[CLOSED]\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cimg style=\"width: 100%; max-width: 450px; height: auto;\" alt=\"CLOSED\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/JFHDBV-CLOSED.gif\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"width: 100%; overflow-x: auto; margin-bottom: 20px;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; background-color: rgb(255, 255, 255); font-size: 16px; font-family: Arial; color: black; height: 425.521px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 22.3958px;\"\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; text-align: center; height: 22.3958px;\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px; height: 22.3958px;\"\u003eUSS-HDBV00011\u003c\/td\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; text-align: center; height: 22.3958px;\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px; height: 22.3958px;\"\u003eU.S. Solid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 44.7917px;\"\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eSize\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 44.7917px;\"\u003e1\/2\"\u003c\/td\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eWiring Type\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 44.7917px;\"\u003eType B: ON\/OFF Type, Dry Contact\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 44.7917px;\"\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eValve Material\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 44.7917px;\"\u003e304SS\u003c\/td\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eBall Seal\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 44.7917px;\"\u003ePTFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 44.7917px;\"\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eOperating Time\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 44.7917px;\"\u003e20 Seconds\u003c\/td\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eWorking Voltage\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 44.7917px;\"\u003e110V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 22.3958px;\"\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 22.3958px;\"\u003eMax Power\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 22.3958px;\"\u003e20 W\u003c\/td\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 22.3958px;\"\u003eMax Torque\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 22.3958px;\"\u003e50 N m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 89.5833px;\"\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 89.5833px;\"\u003eMax Medium Pressure\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 89.5833px;\"\u003e1.6 Mpa\u003c\/td\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 89.5833px;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 89.5833px;\"\u003e-30°C to 180°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 44.7917px;\"\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eLife Expectancy\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 44.7917px;\"\u003e30,000 to 50,000 Cycles\u003c\/td\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eBore Type\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 44.7917px;\"\u003eFull port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 44.7917px;\"\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eThread Type\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 44.7917px;\"\u003eNPT\u003c\/td\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eOperating State\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 44.7917px;\"\u003eRemain in position\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 67.1875px;\"\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 67.1875px;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 67.1875px;\"\u003e-30°C to 60°C\u003c\/td\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 67.1875px;\"\u003eEnclosure Rating\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 67.1875px;\"\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eWARNINGS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"font-size: 16px; line-height: 26px; color: black; font-family: Arial; margin-bottom: 20px; padding-left: 20px;\"\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003ePower Failure Behavior:\u003c\/strong\u003e This valve remains in its current position during a power outage. It does not automatically return to a preset position.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eVoltage Match Required:\u003c\/strong\u003e Supply voltage must match the actuator rating exactly. Incorrect voltage may permanently damage the unit.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eDedicated Power Circuit:\u003c\/strong\u003e Each actuator requires its own fuse-protected power supply. Do not connect multiple actuators in parallel.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eDisconnect Power Before Service:\u003c\/strong\u003e Always disconnect power before wiring, maintenance, or using the manual override.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eIP65 Weather Resistant:\u003c\/strong\u003e Suitable for outdoor use, but additional protection is recommended for permanent outdoor installations.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eLow Power Consumption:\u003c\/strong\u003e Power is only used during opening and closing. No power is consumed when fully open or fully closed.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eProfessional Installation Recommended:\u003c\/strong\u003e Installation should be performed by qualified personnel familiar with electrical control systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"font-size: 16px; line-height: 26px; font-family: Arial; color: black; margin-bottom: 20px;\"\u003e\n\u003cp style=\"margin-bottom: 10px;\"\u003e\u003cstrong\u003e1: Can I manually operate the valve?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px; padding-left: 15px;\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes. The actuator features a manual override. We recommend manually cycling the valve before installation to verify smooth operation, and using the adjustment screws during commissioning to fine-tune open\/close positions.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 10px;\"\u003e\u003cstrong\u003e2: Can this valve be installed outdoors?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px; padding-left: 15px;\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes, depending on your model's IP rating. While our heavy-duty actuators are weather-resistant, we highly recommend using a protective cover or shelter for permanent outdoor installations to shield the unit from direct UV rays and ice buildup.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 10px;\"\u003e\u003cstrong\u003e3: Is this valve suitable for high-viscosity fluids or particulates?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px; padding-left: 15px;\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes, but with torque considerations. Our heavy-duty series is built for high-torque applications. However, extremely viscous mediums or large particulates will increase resistance. Ensure the operating torque remains within the actuator's rated capacity to avoid stalling.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 10px;\"\u003e\u003cstrong\u003e4: Is it normal for the actuator to feel hot during operation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px; padding-left: 15px;\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes, it is normal to feel warm during continuous cycling. The actuator includes built-in power-limiting features to prevent overheating under normal use. If the housing becomes too hot to touch, please check that you are not exceeding the recommended duty cycle or the ambient temperature limit (-30°C to +60°C).\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 10px;\"\u003e\u003cstrong\u003e5: Can I wire multiple actuators in parallel on the same circuit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px; padding-left: 15px;\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e No. Each motorized actuator must be installed on its own dedicated, fuse-protected circuit to ensure proper signal response and prevent electrical interference or damage.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 16px; margin-top: 25px;\"\u003eDownload user manual \u003ca style=\"color: #0066cc; text-decoration: underline;\" rel=\"noopener\" href=\"http:\/\/file.ussolid.com\/content\/JFHDBV\/JFHDBV-%20Electric%20Actuated%20Ball%20Valve%20instruction%20manual.pdf\" target=\"_blank\"\u003ehere\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"font-family: Arial, sans-serif; color: black;\" class=\"mobile-only\"\u003e\n\u003ch3 style=\"margin-bottom: 20px; margin-top: 0;\"\u003e\u003cimg alt=\"Product Introduction\" style=\"width: 100%; max-width: 100%; height: auto; display: block;\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/%E6%9D%A1%E7%8A%B6%E5%9B%BE.jpg\"\u003e\u003c\/h3\u003e\n\u003cp style=\"font-size: 20px; font-family: Arial; text-align: left; margin-top: 0px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 15px; line-height: 24px; font-family: Arial; color: black; margin-bottom: 20px;\"\u003eThis premium flow control solution integrates a heavy-duty 3-piece stainless steel ball valve with a high-performance electric actuator. Engineered for reliability and precision, it provides a comprehensive hardware suite for automated systems, offering superior durability, seamless integration, and simplified maintenance in demanding industrial environments.\u003c\/p\u003e\n\u003cp style=\"font-size: 20px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"margin-bottom: 20px; text-align: center;\"\u003e\u003cimg alt=\"\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/FEATURES.webp\"\u003e\u003c\/div\u003e\n\u003cul style=\"font-size: 15px; line-height: 24px; color: black; font-family: Arial; margin-bottom: 20px; padding-left: 20px;\"\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003ePremium Material Construction:\u003c\/strong\u003e Crafted from high-grade 304 stainless steel, the valve body is highly resistant to corrosion, making it suitable for handling weak acids, weak alkalis, chemical solvents, and water.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eMaintenance-Friendly 3-Piece Design:\u003c\/strong\u003e The innovative 3-piece body construction allows for seamless in-line maintenance. Internal components can be easily cleaned or replaced without the need to disconnect the pipes, significantly reducing downtime and service costs.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eHigh-Pressure \u0026amp; Full-Bore Efficiency:\u003c\/strong\u003e Designed for maximum performance, the full-bore configuration guarantees minimal pressure drop, ensuring optimal flow capacity even in high-pressure systems.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eSmart Automation Ready:\u003c\/strong\u003e Equipped with integrated limit switches and position feedback, the actuator allows for seamless integration with PLC systems, enabling precise remote control, real-time monitoring, and full automation in complex industrial processes.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eHigh-Torque Reliability:\u003c\/strong\u003e Powered by a compact yet robust heavy-duty motor, the actuator delivers a steady torque of 100Nm, ensuring consistent full-port opening and reliable drop-tight sealing for every cycle.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eEnhanced Safety \u0026amp; Self-Locking:\u003c\/strong\u003e The actuator features an integrated self-locking mechanism to ensure valve stability and system integrity. Additionally, a built-in manual override port ensures safe, reliable intervention during power outages or emergencies.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eRugged Outdoor Durability:\u003c\/strong\u003e Engineered for the elements, the unit is encased in a powder-coated polyester aluminum housing, providing exceptional resistance to corrosion and harsh weather.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eAdvanced Circuitry Protection:\u003c\/strong\u003e To ensure long-term electrical reliability, the internal PCBA is treated with a protective sealant, effectively preventing damage from moisture, condensation, and short circuits.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size: 20px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px;\"\u003e\u003cimg alt=\"Applications\" style=\"width: 100%; max-width: 100%; height: auto; display: block;\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/Application.png\"\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 20px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eWIRING DIAGRAMS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; gap: 12px; margin-bottom: 20px;\"\u003e\n\u003cimg alt=\"Wiring Diagram 1\" style=\"width: 100%; max-width: 100%; height: auto; display: block;\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/Wiring-AB.jpg\"\u003e \u003cimg alt=\"Wiring Diagram 2\" style=\"width: 100%; max-width: 100%; height: auto; display: block;\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/Wiring-CD.jpg\"\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 20px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eELECTRIC WIRING\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; gap: 15px; margin-bottom: 20px;\"\u003e\n\u003cdiv style=\"width: 100%; text-align: center;\"\u003e\n\u003ch4 style=\"font-size: 15px; margin-top: 0; margin-bottom: 10px;\"\u003e\u003cstrong\u003e[OPEN]\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cimg style=\"width: 100%; max-width: 100%; height: auto;\" alt=\"OPEN\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/JFHDBV-OPEN.gif\"\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"width: 100%; text-align: center;\"\u003e\n\u003ch4 style=\"font-size: 15px; margin-top: 0; margin-bottom: 10px;\"\u003e\u003cstrong\u003e[CLOSED]\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cimg style=\"width: 100%; max-width: 100%; height: auto;\" alt=\"CLOSED\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/JFHDBV-CLOSED.gif\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 20px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"width: 100%; overflow-x: auto; margin-bottom: 20px;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; background-color: rgb(255, 255, 255); font-size: 15px; font-family: Arial; color: black; height: 425.521px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 22.3958px;\"\u003e\n\u003cth style=\"width: 20%; padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; text-align: center; height: 22.3958px;\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 6px; height: 22.3958px;\"\u003eUSS-HDBV00015\u003c\/td\u003e\n\u003cth style=\"width: 20%; padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; text-align: center; height: 22.3958px;\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 6px; height: 22.3958px;\"\u003eU.S. Solid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 44.7917px;\"\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eSize\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 44.7917px;\"\u003e1 1\/2\"\u003c\/td\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eWiring Type\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 44.7917px;\"\u003eType B: ON\/OFF Type, Dry Contact\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 44.7917px;\"\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eValve Material\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 44.7917px;\"\u003e304SS\u003c\/td\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eBall Seal\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 44.7917px;\"\u003ePTFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 44.7917px;\"\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eOperating Time\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 44.7917px;\"\u003e30 Seconds\u003c\/td\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eWorking Voltage\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 44.7917px;\"\u003e110V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 22.3958px;\"\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 22.3958px;\"\u003eMax Power\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 22.3958px;\"\u003e30 W\u003c\/td\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 22.3958px;\"\u003eMax Torque\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 22.3958px;\"\u003e100 N m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 89.5833px;\"\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 89.5833px;\"\u003eMax Medium Pressure\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 89.5833px;\"\u003e1.6 Mpa\u003c\/td\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 89.5833px;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 89.5833px;\"\u003e-30°C to 180°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 44.7917px;\"\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eLife Expectancy\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 44.7917px;\"\u003e30,000 to 50,000 Cycles\u003c\/td\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eBore Type\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 44.7917px;\"\u003eFull port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 44.7917px;\"\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eThread Type\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 44.7917px;\"\u003eNPT\u003c\/td\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eOperating State\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 44.7917px;\"\u003eRemain in position\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 67.1875px;\"\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 67.1875px;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 67.1875px;\"\u003e-30°C to 60°C\u003c\/td\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 67.1875px;\"\u003eEnclosure Rating\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 67.1875px;\"\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 20px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eWARNINGS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"font-size: 15px; line-height: 24px; color: black; font-family: Arial; margin-bottom: 20px; padding-left: 20px;\"\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003ePower Failure Behavior:\u003c\/strong\u003e This valve remains in its current position during a power outage. It does not automatically return to a preset position.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eVoltage Match Required:\u003c\/strong\u003e Supply voltage must match the actuator rating exactly. Incorrect voltage may permanently damage the unit.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eDedicated Power Circuit:\u003c\/strong\u003e Each actuator requires its own fuse-protected power supply. Do not connect multiple actuators in parallel.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eDisconnect Power Before Service:\u003c\/strong\u003e Always disconnect power before wiring, maintenance, or using the manual override.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eIP65 Weather Resistant:\u003c\/strong\u003e Suitable for outdoor use, but additional protection is recommended for permanent outdoor installations.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eLow Power Consumption:\u003c\/strong\u003e Power is only used during opening and closing. No power is consumed when fully open or fully closed.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eProfessional Installation Recommended:\u003c\/strong\u003e Installation should be performed by qualified personnel familiar with electrical control systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size: 20px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"font-size: 15px; line-height: 24px; font-family: Arial; color: black; margin-bottom: 20px;\"\u003e\n\u003cp style=\"margin-bottom: 10px;\"\u003e\u003cstrong\u003e1: Can I manually operate the valve?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px; padding-left: 15px;\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes. The actuator features a manual override. We recommend manually cycling the valve before installation to verify smooth operation, and using the adjustment screws during commissioning to fine-tune open\/close positions.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 10px;\"\u003e\u003cstrong\u003e2: Can this valve be installed outdoors?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px; padding-left: 15px;\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes, depending on your model's IP rating. While our heavy-duty actuators are weather-resistant, we highly recommend using a protective cover or shelter for permanent outdoor installations to shield the unit from direct UV rays and ice buildup.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 10px;\"\u003e\u003cstrong\u003e3: Is this valve suitable for high-viscosity fluids or particulates?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px; padding-left: 15px;\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes, but with torque considerations. Our heavy-duty series is built for high-torque applications. However, extremely viscous mediums or large particulates will increase resistance. Ensure the operating torque remains within the actuator's rated capacity to avoid stalling.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 10px;\"\u003e\u003cstrong\u003e4: Is it normal for the actuator to feel hot during operation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px; padding-left: 15px;\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes, it is normal to feel warm during continuous cycling. The actuator includes built-in power-limiting features to prevent overheating under normal use. If the housing becomes too hot to touch, please check that you are not exceeding the recommended duty cycle or the ambient temperature limit (-30°C to +60°C).\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 10px;\"\u003e\u003cstrong\u003e5: Can I wire multiple actuators in parallel on the same circuit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px; padding-left: 15px;\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e No. Each motorized actuator must be installed on its own dedicated, fuse-protected circuit to ensure proper signal response and prevent electrical interference or damage.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 15px; margin-top: 25px;\"\u003eDownload user manual \u003ca style=\"color: #0066cc; text-decoration: underline;\" rel=\"noopener\" href=\"http:\/\/file.ussolid.com\/content\/JFHDBV\/JFHDBV-%20Electric%20Actuated%20Ball%20Valve%20instruction%20manual.pdf\" target=\"_blank\"\u003ehere\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"U.S. Solid","offers":[{"title":"Default Title","offer_id":48293067423999,"sku":"JFHDBV00015","price":359.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/2_1792d9c1-5082-4238-af11-3dad3d453610.jpg?v=1778312904"},{"product_id":"2-electric-actuated-ball-valve-heavy-duty-3-piece-industrial-ball-valve-304ss","title":"2\" Electric Actuated Ball Valve, 110V AC Heavy Duty 3-Piece Industrial Ball Valve,304SS, ON\/OFF Type, Dry Contact","description":"\u003cstyle\u003e\n  .mobile-only {\n    display: none;\n  }\n\n  .desktop-only img,\n  .mobile-only img {\n    max-width: 100%;\n    height: auto;\n  }\n\n  @media only screen and (max-width: 600px) {\n    .desktop-only {\n      display: none !important;\n    }\n\n    .mobile-only {\n      display: block !important;\n      font-family: Arial, sans-serif;\n      color: black;\n    }\n\n    .mobile-only table {\n      min-width: 620px;\n    }\n\n    .mobile-only ul {\n      padding-left: 18px !important;\n    }\n  }\n\n  @media only screen and (min-width: 601px) {\n    .desktop-only {\n      display: block !important;\n    }\n\n    .mobile-only {\n      display: none !important;\n    }\n  }\n\u003c\/style\u003e\n\u003cdiv class=\"desktop-only\" style=\"font-family: Arial, sans-serif; color: black;\"\u003e\n\u003ch3 style=\"margin-bottom: 20px; margin-top: 0;\"\u003e\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/%E6%9D%A1%E7%8A%B6%E5%9B%BE.jpg\" style=\"width: 100%; max-width: 100%; height: auto; display: block;\" alt=\"Product Introduction\"\u003e\u003c\/h3\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top: 0px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; line-height: 26px; font-family: Arial; color: black; margin-bottom: 20px;\"\u003eThis premium flow control solution integrates a heavy-duty 3-piece stainless steel ball valve with a high-performance electric actuator. Engineered for reliability and precision, it provides a comprehensive hardware suite for automated systems, offering superior durability, seamless integration, and simplified maintenance in demanding industrial environments.\u003c\/p\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"margin-bottom: 20px; text-align: center;\"\u003e\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/FEATURES.webp\" alt=\"\"\u003e\u003c\/div\u003e\n\u003cul style=\"font-size: 16px; line-height: 26px; color: black; font-family: Arial; margin-bottom: 20px; padding-left: 20px;\"\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003ePremium Material Construction:\u003c\/strong\u003e Crafted from high-grade 304 stainless steel, the valve body is highly resistant to corrosion, making it suitable for handling weak acids, weak alkalis, chemical solvents, and water.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eMaintenance-Friendly 3-Piece Design:\u003c\/strong\u003e The innovative 3-piece body construction allows for seamless in-line maintenance. Internal components can be easily cleaned or replaced without the need to disconnect the pipes, significantly reducing downtime and service costs.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eHigh-Pressure \u0026amp; Full-Bore Efficiency:\u003c\/strong\u003e Designed for maximum performance, the full-bore configuration guarantees minimal pressure drop, ensuring optimal flow capacity even in high-pressure systems.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eSmart Automation Ready:\u003c\/strong\u003e Equipped with integrated limit switches and position feedback, the actuator allows for seamless integration with PLC systems, enabling precise remote control, real-time monitoring, and full automation in complex industrial processes.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eHigh-Torque Reliability:\u003c\/strong\u003e Powered by a compact yet robust heavy-duty motor, the actuator delivers a steady torque of 50Nm, ensuring consistent full-port opening and reliable drop-tight sealing for every cycle.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eEnhanced Safety \u0026amp; Self-Locking:\u003c\/strong\u003e The actuator features an integrated self-locking mechanism to ensure valve stability and system integrity. Additionally, a built-in manual override port ensures safe, reliable intervention during power outages or emergencies.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eRugged Outdoor Durability:\u003c\/strong\u003e Engineered for the elements, the unit is encased in a powder-coated polyester aluminum housing, providing exceptional resistance to corrosion and harsh weather.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eAdvanced Circuitry Protection:\u003c\/strong\u003e To ensure long-term electrical reliability, the internal PCBA is treated with a protective sealant, effectively preventing damage from moisture, condensation, and short circuits.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px;\"\u003e\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/Application.png\" style=\"width: 100%; max-width: 100%; height: auto; display: block;\" alt=\"Applications\"\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eWIRING DIAGRAMS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 15px; margin-bottom: 20px;\"\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/Wiring-AB.jpg\" style=\"flex: 1; min-width: 280px; max-width: 100%; height: auto;\" alt=\"Wiring Diagram 1\"\u003e \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/Wiring-CD.jpg\" style=\"flex: 1; min-width: 280px; max-width: 100%; height: auto;\" alt=\"Wiring Diagram 2\"\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eELECTRIC WIRING\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 20px; margin-bottom: 20px;\"\u003e\n\u003cdiv style=\"flex: 1; min-width: 280px; text-align: center;\"\u003e\n\u003ch4 style=\"font-size: 16px; margin-top: 0; margin-bottom: 10px;\"\u003e\u003cstrong\u003e[OPEN]\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/JFHDBV-OPEN.gif\" alt=\"OPEN\" style=\"width: 100%; max-width: 450px; height: auto;\"\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; min-width: 280px; text-align: center;\"\u003e\n\u003ch4 style=\"font-size: 16px; margin-top: 0; margin-bottom: 10px;\"\u003e\u003cstrong\u003e[CLOSED]\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/JFHDBV-CLOSED.gif\" alt=\"CLOSED\" style=\"width: 100%; max-width: 450px; height: auto;\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"width: 100%; overflow-x: auto; margin-bottom: 20px;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; background-color: rgb(255, 255, 255); font-size: 16px; font-family: Arial; color: black; height: 425.521px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 22.3958px;\"\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; text-align: center; height: 22.3958px;\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px; height: 22.3958px;\"\u003eUSS-HDBV00011\u003c\/td\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; text-align: center; height: 22.3958px;\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px; height: 22.3958px;\"\u003eU.S. Solid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 44.7917px;\"\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eSize\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 44.7917px;\"\u003e1\/2\"\u003c\/td\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eWiring Type\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 44.7917px;\"\u003eType B: ON\/OFF Type, Dry Contact\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 44.7917px;\"\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eValve Material\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 44.7917px;\"\u003e304SS\u003c\/td\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eBall Seal\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 44.7917px;\"\u003ePTFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 44.7917px;\"\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eOperating Time\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 44.7917px;\"\u003e20 Seconds\u003c\/td\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eWorking Voltage\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 44.7917px;\"\u003e110V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 22.3958px;\"\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 22.3958px;\"\u003eMax Power\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 22.3958px;\"\u003e20 W\u003c\/td\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 22.3958px;\"\u003eMax Torque\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 22.3958px;\"\u003e50 N m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 89.5833px;\"\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 89.5833px;\"\u003eMax Medium Pressure\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 89.5833px;\"\u003e1.6 Mpa\u003c\/td\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 89.5833px;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 89.5833px;\"\u003e-30°C to 180°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 44.7917px;\"\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eLife Expectancy\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 44.7917px;\"\u003e30,000 to 50,000 Cycles\u003c\/td\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eBore Type\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 44.7917px;\"\u003eFull port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 44.7917px;\"\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eThread Type\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 44.7917px;\"\u003eNPT\u003c\/td\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eOperating State\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 44.7917px;\"\u003eRemain in position\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 67.1875px;\"\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 67.1875px;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 67.1875px;\"\u003e-30°C to 60°C\u003c\/td\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 67.1875px;\"\u003eEnclosure Rating\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 67.1875px;\"\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eWARNINGS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"font-size: 16px; line-height: 26px; color: black; font-family: Arial; margin-bottom: 20px; padding-left: 20px;\"\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003ePower Failure Behavior:\u003c\/strong\u003e This valve remains in its current position during a power outage. It does not automatically return to a preset position.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eVoltage Match Required:\u003c\/strong\u003e Supply voltage must match the actuator rating exactly. Incorrect voltage may permanently damage the unit.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eDedicated Power Circuit:\u003c\/strong\u003e Each actuator requires its own fuse-protected power supply. Do not connect multiple actuators in parallel.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eDisconnect Power Before Service:\u003c\/strong\u003e Always disconnect power before wiring, maintenance, or using the manual override.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eIP65 Weather Resistant:\u003c\/strong\u003e Suitable for outdoor use, but additional protection is recommended for permanent outdoor installations.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eLow Power Consumption:\u003c\/strong\u003e Power is only used during opening and closing. No power is consumed when fully open or fully closed.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eProfessional Installation Recommended:\u003c\/strong\u003e Installation should be performed by qualified personnel familiar with electrical control systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"font-size: 16px; line-height: 26px; font-family: Arial; color: black; margin-bottom: 20px;\"\u003e\n\u003cp style=\"margin-bottom: 10px;\"\u003e\u003cstrong\u003e1: Can I manually operate the valve?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px; padding-left: 15px;\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes. The actuator features a manual override. We recommend manually cycling the valve before installation to verify smooth operation, and using the adjustment screws during commissioning to fine-tune open\/close positions.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 10px;\"\u003e\u003cstrong\u003e2: Can this valve be installed outdoors?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px; padding-left: 15px;\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes, depending on your model's IP rating. While our heavy-duty actuators are weather-resistant, we highly recommend using a protective cover or shelter for permanent outdoor installations to shield the unit from direct UV rays and ice buildup.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 10px;\"\u003e\u003cstrong\u003e3: Is this valve suitable for high-viscosity fluids or particulates?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px; padding-left: 15px;\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes, but with torque considerations. Our heavy-duty series is built for high-torque applications. However, extremely viscous mediums or large particulates will increase resistance. Ensure the operating torque remains within the actuator's rated capacity to avoid stalling.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 10px;\"\u003e\u003cstrong\u003e4: Is it normal for the actuator to feel hot during operation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px; padding-left: 15px;\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes, it is normal to feel warm during continuous cycling. The actuator includes built-in power-limiting features to prevent overheating under normal use. If the housing becomes too hot to touch, please check that you are not exceeding the recommended duty cycle or the ambient temperature limit (-30°C to +60°C).\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 10px;\"\u003e\u003cstrong\u003e5: Can I wire multiple actuators in parallel on the same circuit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px; padding-left: 15px;\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e No. Each motorized actuator must be installed on its own dedicated, fuse-protected circuit to ensure proper signal response and prevent electrical interference or damage.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 16px; margin-top: 25px;\"\u003eDownload user manual \u003ca href=\"http:\/\/file.ussolid.com\/content\/JFHDBV\/JFHDBV-%20Electric%20Actuated%20Ball%20Valve%20instruction%20manual.pdf\" rel=\"noopener\" style=\"color: #0066cc; text-decoration: underline;\" target=\"_blank\"\u003ehere\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mobile-only\" style=\"font-family: Arial, sans-serif; color: black;\"\u003e\n\u003ch3 style=\"margin-bottom: 20px; margin-top: 0;\"\u003e\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/%E6%9D%A1%E7%8A%B6%E5%9B%BE.jpg\" style=\"width: 100%; max-width: 100%; height: auto; display: block;\" alt=\"Product Introduction\"\u003e\u003c\/h3\u003e\n\u003cp style=\"font-size: 20px; font-family: Arial; text-align: left; margin-top: 0px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 15px; line-height: 24px; font-family: Arial; color: black; margin-bottom: 20px;\"\u003eThis premium flow control solution integrates a heavy-duty 3-piece stainless steel ball valve with a high-performance electric actuator. Engineered for reliability and precision, it provides a comprehensive hardware suite for automated systems, offering superior durability, seamless integration, and simplified maintenance in demanding industrial environments.\u003c\/p\u003e\n\u003cp style=\"font-size: 20px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"margin-bottom: 20px; text-align: center;\"\u003e\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/FEATURES.webp\" alt=\"\"\u003e\u003c\/div\u003e\n\u003cul style=\"font-size: 15px; line-height: 24px; color: black; font-family: Arial; margin-bottom: 20px; padding-left: 20px;\"\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003ePremium Material Construction:\u003c\/strong\u003e Crafted from high-grade 304 stainless steel, the valve body is highly resistant to corrosion, making it suitable for handling weak acids, weak alkalis, chemical solvents, and water.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eMaintenance-Friendly 3-Piece Design:\u003c\/strong\u003e The innovative 3-piece body construction allows for seamless in-line maintenance. Internal components can be easily cleaned or replaced without the need to disconnect the pipes, significantly reducing downtime and service costs.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eHigh-Pressure \u0026amp; Full-Bore Efficiency:\u003c\/strong\u003e Designed for maximum performance, the full-bore configuration guarantees minimal pressure drop, ensuring optimal flow capacity even in high-pressure systems.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eSmart Automation Ready:\u003c\/strong\u003e Equipped with integrated limit switches and position feedback, the actuator allows for seamless integration with PLC systems, enabling precise remote control, real-time monitoring, and full automation in complex industrial processes.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eHigh-Torque Reliability:\u003c\/strong\u003e Powered by a compact yet robust heavy-duty motor, the actuator delivers a steady torque of 100Nm, ensuring consistent full-port opening and reliable drop-tight sealing for every cycle.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eEnhanced Safety \u0026amp; Self-Locking:\u003c\/strong\u003e The actuator features an integrated self-locking mechanism to ensure valve stability and system integrity. Additionally, a built-in manual override port ensures safe, reliable intervention during power outages or emergencies.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eRugged Outdoor Durability:\u003c\/strong\u003e Engineered for the elements, the unit is encased in a powder-coated polyester aluminum housing, providing exceptional resistance to corrosion and harsh weather.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eAdvanced Circuitry Protection:\u003c\/strong\u003e To ensure long-term electrical reliability, the internal PCBA is treated with a protective sealant, effectively preventing damage from moisture, condensation, and short circuits.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size: 20px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px;\"\u003e\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/Application.png\" style=\"width: 100%; max-width: 100%; height: auto; display: block;\" alt=\"Applications\"\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 20px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eWIRING DIAGRAMS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; gap: 12px; margin-bottom: 20px;\"\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/Wiring-AB.jpg\" style=\"width: 100%; max-width: 100%; height: auto; display: block;\" alt=\"Wiring Diagram 1\"\u003e \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/Wiring-CD.jpg\" style=\"width: 100%; max-width: 100%; height: auto; display: block;\" alt=\"Wiring Diagram 2\"\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 20px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eELECTRIC WIRING\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; gap: 15px; margin-bottom: 20px;\"\u003e\n\u003cdiv style=\"width: 100%; text-align: center;\"\u003e\n\u003ch4 style=\"font-size: 15px; margin-top: 0; margin-bottom: 10px;\"\u003e\u003cstrong\u003e[OPEN]\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/JFHDBV-OPEN.gif\" alt=\"OPEN\" style=\"width: 100%; max-width: 100%; height: auto;\"\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"width: 100%; text-align: center;\"\u003e\n\u003ch4 style=\"font-size: 15px; margin-top: 0; margin-bottom: 10px;\"\u003e\u003cstrong\u003e[CLOSED]\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/JFHDBV-CLOSED.gif\" alt=\"CLOSED\" style=\"width: 100%; max-width: 100%; height: auto;\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 20px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"width: 100%; overflow-x: auto; margin-bottom: 20px;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; background-color: rgb(255, 255, 255); font-size: 15px; font-family: Arial; color: black; height: 425.521px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 22.3958px;\"\u003e\n\u003cth style=\"width: 20%; padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; text-align: center; height: 22.3958px;\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 6px; height: 22.3958px;\"\u003eUSS-HDBV00016\u003c\/td\u003e\n\u003cth style=\"width: 20%; padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; text-align: center; height: 22.3958px;\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 6px; height: 22.3958px;\"\u003eU.S. Solid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 44.7917px;\"\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eSize\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 44.7917px;\"\u003e2\"\u003c\/td\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eWiring Type\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 44.7917px;\"\u003eType B: ON\/OFF Type, Dry Contact\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 44.7917px;\"\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eValve Material\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 44.7917px;\"\u003e304SS\u003c\/td\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eBall Seal\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 44.7917px;\"\u003ePTFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 44.7917px;\"\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eOperating Time\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 44.7917px;\"\u003e30 Seconds\u003c\/td\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eWorking Voltage\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 44.7917px;\"\u003e110V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 22.3958px;\"\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 22.3958px;\"\u003eMax Power\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 22.3958px;\"\u003e30 W\u003c\/td\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 22.3958px;\"\u003eMax Torque\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 22.3958px;\"\u003e100 N m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 89.5833px;\"\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 89.5833px;\"\u003eMax Medium Pressure\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 89.5833px;\"\u003e1.6 Mpa\u003c\/td\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 89.5833px;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 89.5833px;\"\u003e-30°C to 180°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 44.7917px;\"\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eLife Expectancy\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 44.7917px;\"\u003e30,000 to 50,000 Cycles\u003c\/td\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eBore Type\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 44.7917px;\"\u003eFull port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 44.7917px;\"\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eThread Type\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 44.7917px;\"\u003eNPT\u003c\/td\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eOperating State\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 44.7917px;\"\u003eRemain in position\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 67.1875px;\"\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 67.1875px;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 67.1875px;\"\u003e-30°C to 60°C\u003c\/td\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 67.1875px;\"\u003eEnclosure Rating\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 67.1875px;\"\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 20px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eWARNINGS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"font-size: 15px; line-height: 24px; color: black; font-family: Arial; margin-bottom: 20px; padding-left: 20px;\"\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003ePower Failure Behavior:\u003c\/strong\u003e This valve remains in its current position during a power outage. It does not automatically return to a preset position.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eVoltage Match Required:\u003c\/strong\u003e Supply voltage must match the actuator rating exactly. Incorrect voltage may permanently damage the unit.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eDedicated Power Circuit:\u003c\/strong\u003e Each actuator requires its own fuse-protected power supply. Do not connect multiple actuators in parallel.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eDisconnect Power Before Service:\u003c\/strong\u003e Always disconnect power before wiring, maintenance, or using the manual override.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eIP65 Weather Resistant:\u003c\/strong\u003e Suitable for outdoor use, but additional protection is recommended for permanent outdoor installations.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eLow Power Consumption:\u003c\/strong\u003e Power is only used during opening and closing. No power is consumed when fully open or fully closed.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eProfessional Installation Recommended:\u003c\/strong\u003e Installation should be performed by qualified personnel familiar with electrical control systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size: 20px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"font-size: 15px; line-height: 24px; font-family: Arial; color: black; margin-bottom: 20px;\"\u003e\n\u003cp style=\"margin-bottom: 10px;\"\u003e\u003cstrong\u003e1: Can I manually operate the valve?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px; padding-left: 15px;\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes. The actuator features a manual override. We recommend manually cycling the valve before installation to verify smooth operation, and using the adjustment screws during commissioning to fine-tune open\/close positions.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 10px;\"\u003e\u003cstrong\u003e2: Can this valve be installed outdoors?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px; padding-left: 15px;\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes, depending on your model's IP rating. While our heavy-duty actuators are weather-resistant, we highly recommend using a protective cover or shelter for permanent outdoor installations to shield the unit from direct UV rays and ice buildup.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 10px;\"\u003e\u003cstrong\u003e3: Is this valve suitable for high-viscosity fluids or particulates?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px; padding-left: 15px;\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes, but with torque considerations. Our heavy-duty series is built for high-torque applications. However, extremely viscous mediums or large particulates will increase resistance. Ensure the operating torque remains within the actuator's rated capacity to avoid stalling.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 10px;\"\u003e\u003cstrong\u003e4: Is it normal for the actuator to feel hot during operation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px; padding-left: 15px;\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes, it is normal to feel warm during continuous cycling. The actuator includes built-in power-limiting features to prevent overheating under normal use. If the housing becomes too hot to touch, please check that you are not exceeding the recommended duty cycle or the ambient temperature limit (-30°C to +60°C).\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 10px;\"\u003e\u003cstrong\u003e5: Can I wire multiple actuators in parallel on the same circuit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px; padding-left: 15px;\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e No. Each motorized actuator must be installed on its own dedicated, fuse-protected circuit to ensure proper signal response and prevent electrical interference or damage.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 15px; margin-top: 25px;\"\u003eDownload user manual \u003ca href=\"http:\/\/file.ussolid.com\/content\/JFHDBV\/JFHDBV-%20Electric%20Actuated%20Ball%20Valve%20instruction%20manual.pdf\" rel=\"noopener\" style=\"color: #0066cc; text-decoration: underline;\" target=\"_blank\"\u003ehere\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"U.S. Solid","offers":[{"title":"Default Title","offer_id":48293071651071,"sku":"JFHDBV00016","price":409.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/2_94657ea2-4cea-4139-83de-a3863f067afd.jpg?v=1778313001"},{"product_id":"1-2-electric-actuated-ball-valve-24v-dc-heavy-duty-3-piece-industrial-ball-valve-304ss-on-off-type-dry-contact","title":"1\/2\" Electric Actuated Ball Valve, DC 24V Heavy Duty 3-Piece Industrial Ball Valve,304SS, ON\/OFF Type, Dry Contact","description":"\u003cstyle\u003e\n  .mobile-only {\n    display: none;\n  }\n\n  .desktop-only img,\n  .mobile-only img {\n    max-width: 100%;\n    height: auto;\n  }\n\n  @media only screen and (max-width: 600px) {\n    .desktop-only {\n      display: none !important;\n    }\n\n    .mobile-only {\n      display: block !important;\n      font-family: Arial, sans-serif;\n      color: black;\n    }\n\n    .mobile-only table {\n      min-width: 620px;\n    }\n\n    .mobile-only ul {\n      padding-left: 18px !important;\n    }\n  }\n\n  @media only screen and (min-width: 601px) {\n    .desktop-only {\n      display: block !important;\n    }\n\n    .mobile-only {\n      display: none !important;\n    }\n  }\n\u003c\/style\u003e\n\u003cdiv style=\"font-family: Arial, sans-serif; color: black;\" class=\"desktop-only\"\u003e\n\u003ch3 style=\"margin-bottom: 20px; margin-top: 0;\"\u003e\u003cimg alt=\"Product Introduction\" style=\"width: 100%; max-width: 100%; height: auto; display: block;\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/%E6%9D%A1%E7%8A%B6%E5%9B%BE.jpg\"\u003e\u003c\/h3\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top: 0px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; line-height: 26px; font-family: Arial; color: black; margin-bottom: 20px;\"\u003eThis premium flow control solution integrates a heavy-duty 3-piece stainless steel ball valve with a high-performance electric actuator. Engineered for reliability and precision, it provides a comprehensive hardware suite for automated systems, offering superior durability, seamless integration, and simplified maintenance in demanding industrial environments.\u003c\/p\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"margin-bottom: 20px; text-align: center;\"\u003e\u003cimg alt=\"\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/FEATURES.webp\"\u003e\u003c\/div\u003e\n\u003cul style=\"font-size: 16px; line-height: 26px; color: black; font-family: Arial; margin-bottom: 20px; padding-left: 20px;\"\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003ePremium Material Construction:\u003c\/strong\u003e Crafted from high-grade 304 stainless steel, the valve body is highly resistant to corrosion, making it suitable for handling weak acids, weak alkalis, chemical solvents, and water.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eMaintenance-Friendly 3-Piece Design:\u003c\/strong\u003e The innovative 3-piece body construction allows for seamless in-line maintenance. Internal components can be easily cleaned or replaced without the need to disconnect the pipes, significantly reducing downtime and service costs.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eHigh-Pressure \u0026amp; Full-Bore Efficiency:\u003c\/strong\u003e Designed for maximum performance, the full-bore configuration guarantees minimal pressure drop, ensuring optimal flow capacity even in high-pressure systems.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eSmart Automation Ready:\u003c\/strong\u003e Equipped with integrated limit switches and position feedback, the actuator allows for seamless integration with PLC systems, enabling precise remote control, real-time monitoring, and full automation in complex industrial processes.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eHigh-Torque Reliability:\u003c\/strong\u003e Powered by a compact yet robust heavy-duty motor, the actuator delivers a steady torque of 50Nm, ensuring consistent full-port opening and reliable drop-tight sealing for every cycle.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eEnhanced Safety \u0026amp; Self-Locking:\u003c\/strong\u003e The actuator features an integrated self-locking mechanism to ensure valve stability and system integrity. Additionally, a built-in manual override port ensures safe, reliable intervention during power outages or emergencies.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eRugged Outdoor Durability:\u003c\/strong\u003e Engineered for the elements, the unit is encased in a powder-coated polyester aluminum housing, providing exceptional resistance to corrosion and harsh weather.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eAdvanced Circuitry Protection:\u003c\/strong\u003e To ensure long-term electrical reliability, the internal PCBA is treated with a protective sealant, effectively preventing damage from moisture, condensation, and short circuits.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px;\"\u003e\u003cimg alt=\"Applications\" style=\"width: 100%; max-width: 100%; height: auto; display: block;\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/Application.png\"\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eWIRING DIAGRAMS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"display: grid; grid-template-columns: repeat(2, minmax(0, 1fr)); gap: 15px; margin-bottom: 20px;\"\u003e\n\u003cimg alt=\"Wiring Diagram A\/B\" style=\"width: 100%; max-width: 100%; height: auto; display: block;\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/Wiring-AB.jpg\"\u003e \u003cimg alt=\"Wiring Diagram C\/D\" style=\"width: 100%; max-width: 100%; height: auto; display: block;\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/Wiring-CD.jpg\"\u003e\n\u003cimg alt=\"Type F: ON\/OFF Type, Standard DC Polarity Reversal Control\" style=\"width: 100%; max-width: 100%; height: auto; display: block;\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/Wiring-ef.jpg\"\u003e \u003cimg alt=\"Wiring Diagram I\/J\" style=\"width: 100%; max-width: 100%; height: auto; display: block;\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/Wiring-IJ.jpg\"\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"width: 100%; overflow-x: auto; margin-bottom: 20px;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; background-color: rgb(255, 255, 255); font-size: 16px; font-family: Arial; color: black; height: 425.521px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 22.3958px;\"\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; text-align: center; height: 22.3958px;\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px; height: 22.3958px;\"\u003eUSS-HDBV00021\u003c\/td\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; text-align: center; height: 22.3958px;\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px; height: 22.3958px;\"\u003eU.S. Solid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 44.7917px;\"\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eSize\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 44.7917px;\"\u003e1\/2\"\u003c\/td\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eWiring Type\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 44.7917px;\"\u003eType F: ON\/OFF Type, Standard DC Polarity Reversal Control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 44.7917px;\"\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eValve Material\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 44.7917px;\"\u003e304SS\u003c\/td\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eBall Seal\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 44.7917px;\"\u003ePTFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 44.7917px;\"\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eOperating Time\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 44.7917px;\"\u003e8 Seconds\u003c\/td\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eWorking Voltage\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 44.7917px;\"\u003e24V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 22.3958px;\"\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 22.3958px;\"\u003eMax Power\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 22.3958px;\"\u003e9.5 W\u003c\/td\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 22.3958px;\"\u003eMax Torque\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 22.3958px;\"\u003e50 N m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 89.5833px;\"\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 89.5833px;\"\u003eMax Medium Pressure\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 89.5833px;\"\u003e1.6 Mpa\u003c\/td\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 89.5833px;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 89.5833px;\"\u003e-30°C to 180°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 44.7917px;\"\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eLife Expectancy\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 44.7917px;\"\u003e30,000 to 50,000 Cycles\u003c\/td\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eBore Type\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 44.7917px;\"\u003eFull port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 44.7917px;\"\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eThread Type\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 44.7917px;\"\u003eNPT\u003c\/td\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eOperating State\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 44.7917px;\"\u003eRemain in position\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 67.1875px;\"\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 67.1875px;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 67.1875px;\"\u003e-30°C to 60°C\u003c\/td\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 67.1875px;\"\u003eEnclosure Rating\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 67.1875px;\"\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eWARNINGS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"font-size: 16px; line-height: 26px; color: black; font-family: Arial; margin-bottom: 20px; padding-left: 20px;\"\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003ePower Failure Behavior:\u003c\/strong\u003e This valve remains in its current position during a power outage. It does not automatically return to a preset position.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eVoltage Match Required:\u003c\/strong\u003e Supply voltage must match the actuator rating exactly. Incorrect voltage may permanently damage the unit.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eDedicated Power Circuit:\u003c\/strong\u003e Each actuator requires its own fuse-protected power supply. Do not connect multiple actuators in parallel.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eDisconnect Power Before Service:\u003c\/strong\u003e Always disconnect power before wiring, maintenance, or using the manual override.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eIP65 Weather Resistant:\u003c\/strong\u003e Suitable for outdoor use, but additional protection is recommended for permanent outdoor installations.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eLow Power Consumption:\u003c\/strong\u003e Power is only used during opening and closing. No power is consumed when fully open or fully closed.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eProfessional Installation Recommended:\u003c\/strong\u003e Installation should be performed by qualified personnel familiar with electrical control systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"font-size: 16px; line-height: 26px; font-family: Arial; color: black; margin-bottom: 20px;\"\u003e\n\u003cp style=\"margin-bottom: 10px;\"\u003e\u003cstrong\u003e1: Can I manually operate the valve?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px; padding-left: 15px;\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes. The actuator features a manual override. We recommend manually cycling the valve before installation to verify smooth operation, and using the adjustment screws during commissioning to fine-tune open\/close positions.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 10px;\"\u003e\u003cstrong\u003e2: Can this valve be installed outdoors?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px; padding-left: 15px;\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes, depending on your model's IP rating. While our heavy-duty actuators are weather-resistant, we highly recommend using a protective cover or shelter for permanent outdoor installations to shield the unit from direct UV rays and ice buildup.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 10px;\"\u003e\u003cstrong\u003e3: Is this valve suitable for high-viscosity fluids or particulates?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px; padding-left: 15px;\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes, but with torque considerations. Our heavy-duty series is built for high-torque applications. However, extremely viscous mediums or large particulates will increase resistance. Ensure the operating torque remains within the actuator's rated capacity to avoid stalling.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 10px;\"\u003e\u003cstrong\u003e4: Is it normal for the actuator to feel hot during operation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px; padding-left: 15px;\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes, it is normal to feel warm during continuous cycling. The actuator includes built-in power-limiting features to prevent overheating under normal use. If the housing becomes too hot to touch, please check that you are not exceeding the recommended duty cycle or the ambient temperature limit (-30°C to +60°C).\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 10px;\"\u003e\u003cstrong\u003e5: Can I wire multiple actuators in parallel on the same circuit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px; padding-left: 15px;\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e No. Each motorized actuator must be installed on its own dedicated, fuse-protected circuit to ensure proper signal response and prevent electrical interference or damage.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 16px; margin-top: 25px;\"\u003eDownload user manual \u003ca style=\"color: #0066cc; text-decoration: underline;\" rel=\"noopener\" href=\"http:\/\/file.ussolid.com\/content\/JFHDBV\/JFHDBV-%20Electric%20Actuated%20Ball%20Valve%20instruction%20manual.pdf\" target=\"_blank\"\u003ehere\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"font-family: Arial, sans-serif; color: black;\" class=\"mobile-only\"\u003e\n\u003ch3 style=\"margin-bottom: 20px; margin-top: 0;\"\u003e\u003cimg alt=\"Product Introduction\" style=\"width: 100%; max-width: 100%; height: auto; display: block;\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/%E6%9D%A1%E7%8A%B6%E5%9B%BE.jpg\"\u003e\u003c\/h3\u003e\n\u003cp style=\"font-size: 20px; font-family: Arial; text-align: left; margin-top: 0px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 15px; line-height: 24px; font-family: Arial; color: black; margin-bottom: 20px;\"\u003eThis premium flow control solution integrates a heavy-duty 3-piece stainless steel ball valve with a high-performance electric actuator. Engineered for reliability and precision, it provides a comprehensive hardware suite for automated systems, offering superior durability, seamless integration, and simplified maintenance in demanding industrial environments.\u003c\/p\u003e\n\u003cp style=\"font-size: 20px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"margin-bottom: 20px; text-align: center;\"\u003e\u003cimg alt=\"\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/FEATURES.webp\"\u003e\u003c\/div\u003e\n\u003cul style=\"font-size: 15px; line-height: 24px; color: black; font-family: Arial; margin-bottom: 20px; padding-left: 20px;\"\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003ePremium Material Construction:\u003c\/strong\u003e Crafted from high-grade 304 stainless steel, the valve body is highly resistant to corrosion, making it suitable for handling weak acids, weak alkalis, chemical solvents, and water.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eMaintenance-Friendly 3-Piece Design:\u003c\/strong\u003e The innovative 3-piece body construction allows for seamless in-line maintenance. Internal components can be easily cleaned or replaced without the need to disconnect the pipes, significantly reducing downtime and service costs.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eHigh-Pressure \u0026amp; Full-Bore Efficiency:\u003c\/strong\u003e Designed for maximum performance, the full-bore configuration guarantees minimal pressure drop, ensuring optimal flow capacity even in high-pressure systems.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eSmart Automation Ready:\u003c\/strong\u003e Equipped with integrated limit switches and position feedback, the actuator allows for seamless integration with PLC systems, enabling precise remote control, real-time monitoring, and full automation in complex industrial processes.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eHigh-Torque Reliability:\u003c\/strong\u003e Powered by a compact yet robust heavy-duty motor, the actuator delivers a steady torque of 50Nm, ensuring consistent full-port opening and reliable drop-tight sealing for every cycle.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eEnhanced Safety \u0026amp; Self-Locking:\u003c\/strong\u003e The actuator features an integrated self-locking mechanism to ensure valve stability and system integrity. Additionally, a built-in manual override port ensures safe, reliable intervention during power outages or emergencies.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eRugged Outdoor Durability:\u003c\/strong\u003e Engineered for the elements, the unit is encased in a powder-coated polyester aluminum housing, providing exceptional resistance to corrosion and harsh weather.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eAdvanced Circuitry Protection:\u003c\/strong\u003e To ensure long-term electrical reliability, the internal PCBA is treated with a protective sealant, effectively preventing damage from moisture, condensation, and short circuits.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size: 20px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px;\"\u003e\u003cimg alt=\"Applications\" style=\"width: 100%; max-width: 100%; height: auto; display: block;\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/Application.png\"\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 20px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eWIRING DIAGRAMS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; gap: 12px; margin-bottom: 20px;\"\u003e\n\u003cimg alt=\"Wiring Diagram 1\" style=\"width: 100%; max-width: 100%; height: auto; display: block;\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/Wiring-AB.jpg\"\u003e \u003cimg alt=\"Wiring Diagram 2\" style=\"width: 100%; max-width: 100%; height: auto; display: block;\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/Wiring-CD.jpg\"\u003e \u003cimg alt=\"Type F: ON\/OFF Type, Standard DC Polarity Reversal Control\" style=\"width: 100%; max-width: 100%; height: auto; display: block;\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/Wiring-ef.jpg\"\u003e \u003cimg alt=\"Wiring Diagram I\/J\" style=\"width: 100%; max-width: 100%; height: auto; display: block;\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/Wiring-IJ.jpg\"\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 20px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"width: 100%; overflow-x: auto; margin-bottom: 20px;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; background-color: rgb(255, 255, 255); font-size: 15px; font-family: Arial; color: black; height: 443.656px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 22.3854px;\"\u003e\n\u003cth style=\"width: 20.0202%; padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; text-align: center; height: 22.3854px;\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"width: 30.0303%; text-align: left; padding: 6px; height: 22.3854px;\"\u003eUSS-HDBV00021\u003c\/td\u003e\n\u003cth style=\"width: 20.0202%; padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; text-align: center; height: 22.3854px;\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"width: 30.0303%; text-align: left; padding: 6px; height: 22.3854px;\"\u003eU.S. Solid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 63px;\"\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 63px; width: 20.0202%;\"\u003eSize\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 63px; width: 30.0303%;\"\u003e1\/2\"\u003c\/td\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 63px; width: 20.0202%;\"\u003eWiring Type\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 63px; width: 30.0303%;\"\u003eType F: ON\/OFF Type, Standard DC Polarity Reversal Control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 44.7812px;\"\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7812px; width: 20.0202%;\"\u003eValve Material\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 44.7812px; width: 30.0303%;\"\u003e304SS\u003c\/td\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7812px; width: 20.0202%;\"\u003eBall Seal\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 44.7812px; width: 30.0303%;\"\u003ePTFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 44.7812px;\"\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7812px; width: 20.0202%;\"\u003eOperating Time\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 44.7812px; width: 30.0303%;\"\u003e8 Seconds\u003c\/td\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7812px; width: 20.0202%;\"\u003eWorking Voltage\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 44.7812px; width: 30.0303%;\"\u003e24V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 22.3854px;\"\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 22.3854px; width: 20.0202%;\"\u003eMax Power\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 22.3854px; width: 30.0303%;\"\u003e9.5 W\u003c\/td\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 22.3854px; width: 20.0202%;\"\u003eMax Torque\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 22.3854px; width: 30.0303%;\"\u003e50 N m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 89.5729px;\"\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 89.5729px; width: 20.0202%;\"\u003eMax Medium Pressure\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 89.5729px; width: 30.0303%;\"\u003e1.6 Mpa\u003c\/td\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 89.5729px; width: 20.0202%;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 89.5729px; width: 30.0303%;\"\u003e-30°C to 180°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 44.7812px;\"\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7812px; width: 20.0202%;\"\u003eLife Expectancy\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 44.7812px; width: 30.0303%;\"\u003e30,000 to 50,000 Cycles\u003c\/td\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7812px; width: 20.0202%;\"\u003eBore Type\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 44.7812px; width: 30.0303%;\"\u003eFull port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 44.7812px;\"\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7812px; width: 20.0202%;\"\u003eThread Type\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 44.7812px; width: 30.0303%;\"\u003eNPT\u003c\/td\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7812px; width: 20.0202%;\"\u003eOperating State\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 44.7812px; width: 30.0303%;\"\u003eRemain in position\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 67.1875px;\"\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 67.1875px; width: 20.0202%;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 67.1875px; width: 30.0303%;\"\u003e-30°C to 60°C\u003c\/td\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 67.1875px; width: 20.0202%;\"\u003eEnclosure Rating\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 67.1875px; width: 30.0303%;\"\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 20px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eWARNINGS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"font-size: 15px; line-height: 24px; color: black; font-family: Arial; margin-bottom: 20px; padding-left: 20px;\"\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003ePower Failure Behavior:\u003c\/strong\u003e This valve remains in its current position during a power outage. It does not automatically return to a preset position.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eVoltage Match Required:\u003c\/strong\u003e Supply voltage must match the actuator rating exactly. Incorrect voltage may permanently damage the unit.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eDedicated Power Circuit:\u003c\/strong\u003e Each actuator requires its own fuse-protected power supply. Do not connect multiple actuators in parallel.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eDisconnect Power Before Service:\u003c\/strong\u003e Always disconnect power before wiring, maintenance, or using the manual override.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eIP65 Weather Resistant:\u003c\/strong\u003e Suitable for outdoor use, but additional protection is recommended for permanent outdoor installations.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eLow Power Consumption:\u003c\/strong\u003e Power is only used during opening and closing. No power is consumed when fully open or fully closed.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eProfessional Installation Recommended:\u003c\/strong\u003e Installation should be performed by qualified personnel familiar with electrical control systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size: 20px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"font-size: 15px; line-height: 24px; font-family: Arial; color: black; margin-bottom: 20px;\"\u003e\n\u003cp style=\"margin-bottom: 10px;\"\u003e\u003cstrong\u003e1: Can I manually operate the valve?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px; padding-left: 15px;\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes. The actuator features a manual override. We recommend manually cycling the valve before installation to verify smooth operation, and using the adjustment screws during commissioning to fine-tune open\/close positions.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 10px;\"\u003e\u003cstrong\u003e2: Can this valve be installed outdoors?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px; padding-left: 15px;\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes, depending on your model's IP rating. While our heavy-duty actuators are weather-resistant, we highly recommend using a protective cover or shelter for permanent outdoor installations to shield the unit from direct UV rays and ice buildup.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 10px;\"\u003e\u003cstrong\u003e3: Is this valve suitable for high-viscosity fluids or particulates?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px; padding-left: 15px;\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes, but with torque considerations. Our heavy-duty series is built for high-torque applications. However, extremely viscous mediums or large particulates will increase resistance. Ensure the operating torque remains within the actuator's rated capacity to avoid stalling.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 10px;\"\u003e\u003cstrong\u003e4: Is it normal for the actuator to feel hot during operation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px; padding-left: 15px;\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes, it is normal to feel warm during continuous cycling. The actuator includes built-in power-limiting features to prevent overheating under normal use. If the housing becomes too hot to touch, please check that you are not exceeding the recommended duty cycle or the ambient temperature limit (-30°C to +60°C).\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 10px;\"\u003e\u003cstrong\u003e5: Can I wire multiple actuators in parallel on the same circuit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px; padding-left: 15px;\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e No. Each motorized actuator must be installed on its own dedicated, fuse-protected circuit to ensure proper signal response and prevent electrical interference or damage.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 15px; margin-top: 25px;\"\u003eDownload user manual \u003ca style=\"color: #0066cc; text-decoration: underline;\" rel=\"noopener\" href=\"http:\/\/file.ussolid.com\/content\/JFHDBV\/JFHDBV-%20Electric%20Actuated%20Ball%20Valve%20instruction%20manual.pdf\" target=\"_blank\"\u003ehere\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"U.S. Solid","offers":[{"title":"Default Title","offer_id":48808369258751,"sku":"JFHDBV00021","price":209.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/2_b3ba6799-5154-4d04-a8e2-cf8e8ecfe1ba.jpg?v=1784015242"},{"product_id":"3-4-electric-actuated-ball-valve-dc-24v-heavy-duty-3-piece-industrial-ball-valve-304ss-on-off-type-dry-contact","title":"3\/4\" Electric Actuated Ball Valve, DC 24V Heavy Duty 3-Piece Industrial Ball Valve,304SS, ON\/OFF Type, Dry Contact","description":"\u003cstyle\u003e\n  .mobile-only {\n    display: none;\n  }\n\n  .desktop-only img,\n  .mobile-only img {\n    max-width: 100%;\n    height: auto;\n  }\n\n  @media only screen and (max-width: 600px) {\n    .desktop-only {\n      display: none !important;\n    }\n\n    .mobile-only {\n      display: block !important;\n      font-family: Arial, sans-serif;\n      color: black;\n    }\n\n    .mobile-only table {\n      min-width: 620px;\n    }\n\n    .mobile-only ul {\n      padding-left: 18px !important;\n    }\n  }\n\n  @media only screen and (min-width: 601px) {\n    .desktop-only {\n      display: block !important;\n    }\n\n    .mobile-only {\n      display: none !important;\n    }\n  }\n\u003c\/style\u003e\n\u003cdiv class=\"desktop-only\" style=\"font-family: Arial, sans-serif; color: black;\"\u003e\n\u003ch3 style=\"margin-bottom: 20px; margin-top: 0;\"\u003e\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/%E6%9D%A1%E7%8A%B6%E5%9B%BE.jpg\" style=\"width: 100%; max-width: 100%; height: auto; display: block;\" alt=\"Product Introduction\"\u003e\u003c\/h3\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top: 0px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; line-height: 26px; font-family: Arial; color: black; margin-bottom: 20px;\"\u003eThis premium flow control solution integrates a heavy-duty 3-piece stainless steel ball valve with a high-performance electric actuator. Engineered for reliability and precision, it provides a comprehensive hardware suite for automated systems, offering superior durability, seamless integration, and simplified maintenance in demanding industrial environments.\u003c\/p\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"margin-bottom: 20px; text-align: center;\"\u003e\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/FEATURES.webp\" alt=\"\"\u003e\u003c\/div\u003e\n\u003cul style=\"font-size: 16px; line-height: 26px; color: black; font-family: Arial; margin-bottom: 20px; padding-left: 20px;\"\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003ePremium Material Construction:\u003c\/strong\u003e Crafted from high-grade 304 stainless steel, the valve body is highly resistant to corrosion, making it suitable for handling weak acids, weak alkalis, chemical solvents, and water.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eMaintenance-Friendly 3-Piece Design:\u003c\/strong\u003e The innovative 3-piece body construction allows for seamless in-line maintenance. Internal components can be easily cleaned or replaced without the need to disconnect the pipes, significantly reducing downtime and service costs.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eHigh-Pressure \u0026amp; Full-Bore Efficiency:\u003c\/strong\u003e Designed for maximum performance, the full-bore configuration guarantees minimal pressure drop, ensuring optimal flow capacity even in high-pressure systems.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eSmart Automation Ready:\u003c\/strong\u003e Equipped with integrated limit switches and position feedback, the actuator allows for seamless integration with PLC systems, enabling precise remote control, real-time monitoring, and full automation in complex industrial processes.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eHigh-Torque Reliability:\u003c\/strong\u003e Powered by a compact yet robust heavy-duty motor, the actuator delivers a steady torque of 50Nm, ensuring consistent full-port opening and reliable drop-tight sealing for every cycle.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eEnhanced Safety \u0026amp; Self-Locking:\u003c\/strong\u003e The actuator features an integrated self-locking mechanism to ensure valve stability and system integrity. Additionally, a built-in manual override port ensures safe, reliable intervention during power outages or emergencies.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eRugged Outdoor Durability:\u003c\/strong\u003e Engineered for the elements, the unit is encased in a powder-coated polyester aluminum housing, providing exceptional resistance to corrosion and harsh weather.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eAdvanced Circuitry Protection:\u003c\/strong\u003e To ensure long-term electrical reliability, the internal PCBA is treated with a protective sealant, effectively preventing damage from moisture, condensation, and short circuits.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px;\"\u003e\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/Application.png\" style=\"width: 100%; max-width: 100%; height: auto; display: block;\" alt=\"Applications\"\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eWIRING DIAGRAMS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"display: grid; grid-template-columns: repeat(2, minmax(0, 1fr)); gap: 15px; margin-bottom: 20px;\"\u003e\n\u003cdiv style=\"width: 100%; aspect-ratio: 1.42 \/ 1; display: flex; align-items: center; justify-content: center; overflow: hidden;\"\u003e\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/Wiring-AB.jpg\" style=\"width: 100%; height: 100%; object-fit: contain; display: block;\" alt=\"Wiring Diagram A\/B\"\u003e\u003c\/div\u003e \u003cdiv style=\"width: 100%; aspect-ratio: 1.42 \/ 1; display: flex; align-items: center; justify-content: center; overflow: hidden;\"\u003e\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/Wiring-CD.jpg\" style=\"width: 100%; height: 100%; object-fit: contain; display: block;\" alt=\"Wiring Diagram C\/D\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"width: 100%; aspect-ratio: 1.42 \/ 1; display: flex; align-items: center; justify-content: center; overflow: hidden;\"\u003e\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/Wiring-ef.jpg\" style=\"width: 100%; height: 100%; object-fit: contain; display: block;\" alt=\"Type F: ON\/OFF Type, Standard DC Polarity Reversal Control\"\u003e\u003c\/div\u003e \u003cdiv style=\"width: 100%; aspect-ratio: 1.42 \/ 1; display: flex; align-items: center; justify-content: center; overflow: hidden;\"\u003e\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/Wiring-IJ.jpg\" style=\"width: 100%; height: 100%; object-fit: contain; display: block;\" alt=\"Wiring Diagram I\/J\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"width: 100%; overflow-x: auto; margin-bottom: 20px;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; background-color: rgb(255, 255, 255); font-size: 16px; font-family: Arial; color: black; height: 425.521px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 22.3958px;\"\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; text-align: center; height: 22.3958px;\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px; height: 22.3958px;\"\u003eUSS-HDBV00022\u003c\/td\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; text-align: center; height: 22.3958px;\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px; height: 22.3958px;\"\u003eU.S. Solid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 44.7917px;\"\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eSize\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 44.7917px;\"\u003e3\/4\"\u003c\/td\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eWiring Type\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 44.7917px;\"\u003eType F: ON\/OFF Type, Standard DC Polarity Reversal Control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 44.7917px;\"\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eValve Material\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 44.7917px;\"\u003e304SS\u003c\/td\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eBall Seal\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 44.7917px;\"\u003ePTFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 44.7917px;\"\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eOperating Time\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 44.7917px;\"\u003e8 Seconds\u003c\/td\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eWorking Voltage\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 44.7917px;\"\u003e24V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 22.3958px;\"\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 22.3958px;\"\u003eMax Power\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 22.3958px;\"\u003e9.5 W\u003c\/td\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 22.3958px;\"\u003eMax Torque\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 22.3958px;\"\u003e50 N m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 89.5833px;\"\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 89.5833px;\"\u003eMax Medium Pressure\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 89.5833px;\"\u003e1.6 Mpa\u003c\/td\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 89.5833px;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 89.5833px;\"\u003e-30°C to 180°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 44.7917px;\"\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eLife Expectancy\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 44.7917px;\"\u003e30,000 to 50,000 Cycles\u003c\/td\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eBore Type\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 44.7917px;\"\u003eFull port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 44.7917px;\"\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eThread Type\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 44.7917px;\"\u003eNPT\u003c\/td\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eOperating State\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 44.7917px;\"\u003eRemain in position\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 67.1875px;\"\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 67.1875px;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 67.1875px;\"\u003e-30°C to 60°C\u003c\/td\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 67.1875px;\"\u003eEnclosure Rating\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 67.1875px;\"\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eWARNINGS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"font-size: 16px; line-height: 26px; color: black; font-family: Arial; margin-bottom: 20px; padding-left: 20px;\"\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003ePower Failure Behavior:\u003c\/strong\u003e This valve remains in its current position during a power outage. It does not automatically return to a preset position.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eVoltage Match Required:\u003c\/strong\u003e Supply voltage must match the actuator rating exactly. Incorrect voltage may permanently damage the unit.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eDedicated Power Circuit:\u003c\/strong\u003e Each actuator requires its own fuse-protected power supply. Do not connect multiple actuators in parallel.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eDisconnect Power Before Service:\u003c\/strong\u003e Always disconnect power before wiring, maintenance, or using the manual override.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eIP65 Weather Resistant:\u003c\/strong\u003e Suitable for outdoor use, but additional protection is recommended for permanent outdoor installations.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eLow Power Consumption:\u003c\/strong\u003e Power is only used during opening and closing. No power is consumed when fully open or fully closed.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eProfessional Installation Recommended:\u003c\/strong\u003e Installation should be performed by qualified personnel familiar with electrical control systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"font-size: 16px; line-height: 26px; font-family: Arial; color: black; margin-bottom: 20px;\"\u003e\n\u003cp style=\"margin-bottom: 10px;\"\u003e\u003cstrong\u003e1: Can I manually operate the valve?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px; padding-left: 15px;\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes. The actuator features a manual override. We recommend manually cycling the valve before installation to verify smooth operation, and using the adjustment screws during commissioning to fine-tune open\/close positions.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 10px;\"\u003e\u003cstrong\u003e2: Can this valve be installed outdoors?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px; padding-left: 15px;\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes, depending on your model's IP rating. While our heavy-duty actuators are weather-resistant, we highly recommend using a protective cover or shelter for permanent outdoor installations to shield the unit from direct UV rays and ice buildup.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 10px;\"\u003e\u003cstrong\u003e3: Is this valve suitable for high-viscosity fluids or particulates?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px; padding-left: 15px;\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes, but with torque considerations. Our heavy-duty series is built for high-torque applications. However, extremely viscous mediums or large particulates will increase resistance. Ensure the operating torque remains within the actuator's rated capacity to avoid stalling.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 10px;\"\u003e\u003cstrong\u003e4: Is it normal for the actuator to feel hot during operation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px; padding-left: 15px;\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes, it is normal to feel warm during continuous cycling. The actuator includes built-in power-limiting features to prevent overheating under normal use. If the housing becomes too hot to touch, please check that you are not exceeding the recommended duty cycle or the ambient temperature limit (-30°C to +60°C).\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 10px;\"\u003e\u003cstrong\u003e5: Can I wire multiple actuators in parallel on the same circuit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px; padding-left: 15px;\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e No. Each motorized actuator must be installed on its own dedicated, fuse-protected circuit to ensure proper signal response and prevent electrical interference or damage.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 16px; margin-top: 25px;\"\u003eDownload user manual \u003ca href=\"http:\/\/file.ussolid.com\/content\/JFHDBV\/JFHDBV-%20Electric%20Actuated%20Ball%20Valve%20instruction%20manual.pdf\" rel=\"noopener\" style=\"color: #0066cc; text-decoration: underline;\" target=\"_blank\"\u003ehere\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mobile-only\" style=\"font-family: Arial, sans-serif; color: black;\"\u003e\n\u003ch3 style=\"margin-bottom: 20px; margin-top: 0;\"\u003e\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/%E6%9D%A1%E7%8A%B6%E5%9B%BE.jpg\" style=\"width: 100%; max-width: 100%; height: auto; display: block;\" alt=\"Product Introduction\"\u003e\u003c\/h3\u003e\n\u003cp style=\"font-size: 20px; font-family: Arial; text-align: left; margin-top: 0px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 15px; line-height: 24px; font-family: Arial; color: black; margin-bottom: 20px;\"\u003eThis premium flow control solution integrates a heavy-duty 3-piece stainless steel ball valve with a high-performance electric actuator. Engineered for reliability and precision, it provides a comprehensive hardware suite for automated systems, offering superior durability, seamless integration, and simplified maintenance in demanding industrial environments.\u003c\/p\u003e\n\u003cp style=\"font-size: 20px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"margin-bottom: 20px; text-align: center;\"\u003e\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/FEATURES.webp\" alt=\"\"\u003e\u003c\/div\u003e\n\u003cul style=\"font-size: 15px; line-height: 24px; color: black; font-family: Arial; margin-bottom: 20px; padding-left: 20px;\"\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003ePremium Material Construction:\u003c\/strong\u003e Crafted from high-grade 304 stainless steel, the valve body is highly resistant to corrosion, making it suitable for handling weak acids, weak alkalis, chemical solvents, and water.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eMaintenance-Friendly 3-Piece Design:\u003c\/strong\u003e The innovative 3-piece body construction allows for seamless in-line maintenance. Internal components can be easily cleaned or replaced without the need to disconnect the pipes, significantly reducing downtime and service costs.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eHigh-Pressure \u0026amp; Full-Bore Efficiency:\u003c\/strong\u003e Designed for maximum performance, the full-bore configuration guarantees minimal pressure drop, ensuring optimal flow capacity even in high-pressure systems.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eSmart Automation Ready:\u003c\/strong\u003e Equipped with integrated limit switches and position feedback, the actuator allows for seamless integration with PLC systems, enabling precise remote control, real-time monitoring, and full automation in complex industrial processes.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eHigh-Torque Reliability:\u003c\/strong\u003e Powered by a compact yet robust heavy-duty motor, the actuator delivers a steady torque of 50Nm, ensuring consistent full-port opening and reliable drop-tight sealing for every cycle.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eEnhanced Safety \u0026amp; Self-Locking:\u003c\/strong\u003e The actuator features an integrated self-locking mechanism to ensure valve stability and system integrity. Additionally, a built-in manual override port ensures safe, reliable intervention during power outages or emergencies.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eRugged Outdoor Durability:\u003c\/strong\u003e Engineered for the elements, the unit is encased in a powder-coated polyester aluminum housing, providing exceptional resistance to corrosion and harsh weather.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eAdvanced Circuitry Protection:\u003c\/strong\u003e To ensure long-term electrical reliability, the internal PCBA is treated with a protective sealant, effectively preventing damage from moisture, condensation, and short circuits.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size: 20px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px;\"\u003e\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/Application.png\" style=\"width: 100%; max-width: 100%; height: auto; display: block;\" alt=\"Applications\"\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 20px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eWIRING DIAGRAMS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; gap: 12px; margin-bottom: 20px;\"\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/Wiring-AB.jpg\" style=\"width: 100%; max-width: 100%; height: auto; display: block;\" alt=\"Wiring Diagram 1\"\u003e \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/Wiring-CD.jpg\" style=\"width: 100%; max-width: 100%; height: auto; display: block;\" alt=\"Wiring Diagram 2\"\u003e \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/Wiring-ef.jpg\" style=\"width: 100%; max-width: 100%; height: auto; display: block;\" alt=\"Type F: ON\/OFF Type, Standard DC Polarity Reversal Control\"\u003e \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/Wiring-IJ.jpg\" style=\"width: 100%; max-width: 100%; height: auto; display: block;\" alt=\"Wiring Diagram I\/J\"\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 20px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"width: 100%; overflow-x: auto; margin-bottom: 20px;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; background-color: rgb(255, 255, 255); font-size: 15px; font-family: Arial; color: black; height: 425.521px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 22.3958px;\"\u003e\n\u003cth style=\"width: 20%; padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; text-align: center; height: 22.3958px;\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 6px; height: 22.3958px;\"\u003eUSS-HDBV00022\u003c\/td\u003e\n\u003cth style=\"width: 20%; padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; text-align: center; height: 22.3958px;\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 6px; height: 22.3958px;\"\u003eU.S. Solid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 44.7917px;\"\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eSize\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 44.7917px;\"\u003e3\/4\"\u003c\/td\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eWiring Type\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 44.7917px;\"\u003eType F: ON\/OFF Type, Standard DC Polarity Reversal Control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 44.7917px;\"\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eValve Material\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 44.7917px;\"\u003e304SS\u003c\/td\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eBall Seal\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 44.7917px;\"\u003ePTFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 44.7917px;\"\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eOperating Time\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 44.7917px;\"\u003e8 Seconds\u003c\/td\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eWorking Voltage\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 44.7917px;\"\u003e24V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 22.3958px;\"\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 22.3958px;\"\u003eMax Power\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 22.3958px;\"\u003e9.5 W\u003c\/td\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 22.3958px;\"\u003eMax Torque\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 22.3958px;\"\u003e50 N m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 89.5833px;\"\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 89.5833px;\"\u003eMax Medium Pressure\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 89.5833px;\"\u003e1.6 Mpa\u003c\/td\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 89.5833px;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 89.5833px;\"\u003e-30°C to 180°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 44.7917px;\"\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eLife Expectancy\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 44.7917px;\"\u003e30,000 to 50,000 Cycles\u003c\/td\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eBore Type\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 44.7917px;\"\u003eFull port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 44.7917px;\"\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eThread Type\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 44.7917px;\"\u003eNPT\u003c\/td\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eOperating State\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 44.7917px;\"\u003eRemain in position\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 67.1875px;\"\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 67.1875px;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 67.1875px;\"\u003e-30°C to 60°C\u003c\/td\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 67.1875px;\"\u003eEnclosure Rating\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 67.1875px;\"\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 20px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eWARNINGS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"font-size: 15px; line-height: 24px; color: black; font-family: Arial; margin-bottom: 20px; padding-left: 20px;\"\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003ePower Failure Behavior:\u003c\/strong\u003e This valve remains in its current position during a power outage. It does not automatically return to a preset position.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eVoltage Match Required:\u003c\/strong\u003e Supply voltage must match the actuator rating exactly. Incorrect voltage may permanently damage the unit.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eDedicated Power Circuit:\u003c\/strong\u003e Each actuator requires its own fuse-protected power supply. Do not connect multiple actuators in parallel.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eDisconnect Power Before Service:\u003c\/strong\u003e Always disconnect power before wiring, maintenance, or using the manual override.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eIP65 Weather Resistant:\u003c\/strong\u003e Suitable for outdoor use, but additional protection is recommended for permanent outdoor installations.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eLow Power Consumption:\u003c\/strong\u003e Power is only used during opening and closing. No power is consumed when fully open or fully closed.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eProfessional Installation Recommended:\u003c\/strong\u003e Installation should be performed by qualified personnel familiar with electrical control systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size: 20px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"font-size: 15px; line-height: 24px; font-family: Arial; color: black; margin-bottom: 20px;\"\u003e\n\u003cp style=\"margin-bottom: 10px;\"\u003e\u003cstrong\u003e1: Can I manually operate the valve?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px; padding-left: 15px;\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes. The actuator features a manual override. We recommend manually cycling the valve before installation to verify smooth operation, and using the adjustment screws during commissioning to fine-tune open\/close positions.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 10px;\"\u003e\u003cstrong\u003e2: Can this valve be installed outdoors?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px; padding-left: 15px;\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes, depending on your model's IP rating. While our heavy-duty actuators are weather-resistant, we highly recommend using a protective cover or shelter for permanent outdoor installations to shield the unit from direct UV rays and ice buildup.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 10px;\"\u003e\u003cstrong\u003e3: Is this valve suitable for high-viscosity fluids or particulates?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px; padding-left: 15px;\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes, but with torque considerations. Our heavy-duty series is built for high-torque applications. However, extremely viscous mediums or large particulates will increase resistance. Ensure the operating torque remains within the actuator's rated capacity to avoid stalling.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 10px;\"\u003e\u003cstrong\u003e4: Is it normal for the actuator to feel hot during operation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px; padding-left: 15px;\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes, it is normal to feel warm during continuous cycling. The actuator includes built-in power-limiting features to prevent overheating under normal use. If the housing becomes too hot to touch, please check that you are not exceeding the recommended duty cycle or the ambient temperature limit (-30°C to +60°C).\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 10px;\"\u003e\u003cstrong\u003e5: Can I wire multiple actuators in parallel on the same circuit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px; padding-left: 15px;\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e No. Each motorized actuator must be installed on its own dedicated, fuse-protected circuit to ensure proper signal response and prevent electrical interference or damage.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 15px; margin-top: 25px;\"\u003eDownload user manual \u003ca href=\"http:\/\/file.ussolid.com\/content\/JFHDBV\/JFHDBV-%20Electric%20Actuated%20Ball%20Valve%20instruction%20manual.pdf\" rel=\"noopener\" style=\"color: #0066cc; text-decoration: underline;\" target=\"_blank\"\u003ehere\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"U.S. Solid","offers":[{"title":"Default Title","offer_id":48808398749951,"sku":"JFHDBV00022","price":219.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/2_0cab5a39-28d0-49a5-b19d-b1f275d1cd1c.jpg?v=1784015567"},{"product_id":"1-electric-actuated-ball-valve-dc-24v-heavy-duty-3-piece-industrial-ball-valve-304ss-on-off-type-dry-contact","title":"1\" Electric Actuated Ball Valve, DC 24V Heavy Duty 3-Piece Industrial Ball Valve,304SS, ON\/OFF Type, Dry Contact","description":"\u003cstyle\u003e\n  .mobile-only {\n    display: none;\n  }\n\n  .desktop-only img,\n  .mobile-only img {\n    max-width: 100%;\n    height: auto;\n  }\n\n  @media only screen and (max-width: 600px) {\n    .desktop-only {\n      display: none !important;\n    }\n\n    .mobile-only {\n      display: block !important;\n      font-family: Arial, sans-serif;\n      color: black;\n    }\n\n    .mobile-only table {\n      min-width: 620px;\n    }\n\n    .mobile-only ul {\n      padding-left: 18px !important;\n    }\n  }\n\n  @media only screen and (min-width: 601px) {\n    .desktop-only {\n      display: block !important;\n    }\n\n    .mobile-only {\n      display: none !important;\n    }\n  }\n\u003c\/style\u003e\n\u003cdiv class=\"desktop-only\" style=\"font-family: Arial, sans-serif; color: black;\"\u003e\n\u003ch3 style=\"margin-bottom: 20px; margin-top: 0;\"\u003e\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/%E6%9D%A1%E7%8A%B6%E5%9B%BE.jpg\" style=\"width: 100%; max-width: 100%; height: auto; display: block;\" alt=\"Product Introduction\"\u003e\u003c\/h3\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top: 0px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; line-height: 26px; font-family: Arial; color: black; margin-bottom: 20px;\"\u003eThis premium flow control solution integrates a heavy-duty 3-piece stainless steel ball valve with a high-performance electric actuator. Engineered for reliability and precision, it provides a comprehensive hardware suite for automated systems, offering superior durability, seamless integration, and simplified maintenance in demanding industrial environments.\u003c\/p\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"margin-bottom: 20px; text-align: center;\"\u003e\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/FEATURES.webp\" alt=\"\"\u003e\u003c\/div\u003e\n\u003cul style=\"font-size: 16px; line-height: 26px; color: black; font-family: Arial; margin-bottom: 20px; padding-left: 20px;\"\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003ePremium Material Construction:\u003c\/strong\u003e Crafted from high-grade 304 stainless steel, the valve body is highly resistant to corrosion, making it suitable for handling weak acids, weak alkalis, chemical solvents, and water.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eMaintenance-Friendly 3-Piece Design:\u003c\/strong\u003e The innovative 3-piece body construction allows for seamless in-line maintenance. Internal components can be easily cleaned or replaced without the need to disconnect the pipes, significantly reducing downtime and service costs.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eHigh-Pressure \u0026amp; Full-Bore Efficiency:\u003c\/strong\u003e Designed for maximum performance, the full-bore configuration guarantees minimal pressure drop, ensuring optimal flow capacity even in high-pressure systems.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eSmart Automation Ready:\u003c\/strong\u003e Equipped with integrated limit switches and position feedback, the actuator allows for seamless integration with PLC systems, enabling precise remote control, real-time monitoring, and full automation in complex industrial processes.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eHigh-Torque Reliability:\u003c\/strong\u003e Powered by a compact yet robust heavy-duty motor, the actuator delivers a steady torque of 50Nm, ensuring consistent full-port opening and reliable drop-tight sealing for every cycle.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eEnhanced Safety \u0026amp; Self-Locking:\u003c\/strong\u003e The actuator features an integrated self-locking mechanism to ensure valve stability and system integrity. Additionally, a built-in manual override port ensures safe, reliable intervention during power outages or emergencies.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eRugged Outdoor Durability:\u003c\/strong\u003e Engineered for the elements, the unit is encased in a powder-coated polyester aluminum housing, providing exceptional resistance to corrosion and harsh weather.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eAdvanced Circuitry Protection:\u003c\/strong\u003e To ensure long-term electrical reliability, the internal PCBA is treated with a protective sealant, effectively preventing damage from moisture, condensation, and short circuits.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px;\"\u003e\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/Application.png\" style=\"width: 100%; max-width: 100%; height: auto; display: block;\" alt=\"Applications\"\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eWIRING DIAGRAMS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"display: grid; grid-template-columns: repeat(2, minmax(0, 1fr)); gap: 15px; margin-bottom: 20px;\"\u003e\n\u003cdiv style=\"width: 100%; aspect-ratio: 1.42 \/ 1; display: flex; align-items: center; justify-content: center; overflow: hidden;\"\u003e\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/Wiring-AB.jpg\" style=\"width: 100%; height: 100%; object-fit: contain; display: block;\" alt=\"Wiring Diagram A\/B\"\u003e\u003c\/div\u003e \u003cdiv style=\"width: 100%; aspect-ratio: 1.42 \/ 1; display: flex; align-items: center; justify-content: center; overflow: hidden;\"\u003e\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/Wiring-CD.jpg\" style=\"width: 100%; height: 100%; object-fit: contain; display: block;\" alt=\"Wiring Diagram C\/D\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"width: 100%; aspect-ratio: 1.42 \/ 1; display: flex; align-items: center; justify-content: center; overflow: hidden;\"\u003e\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/Wiring-ef.jpg\" style=\"width: 100%; height: 100%; object-fit: contain; display: block;\" alt=\"Type F: ON\/OFF Type, Standard DC Polarity Reversal Control\"\u003e\u003c\/div\u003e \u003cdiv style=\"width: 100%; aspect-ratio: 1.42 \/ 1; display: flex; align-items: center; justify-content: center; overflow: hidden;\"\u003e\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/Wiring-IJ.jpg\" style=\"width: 100%; height: 100%; object-fit: contain; display: block;\" alt=\"Wiring Diagram I\/J\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"width: 100%; overflow-x: auto; margin-bottom: 20px;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; background-color: rgb(255, 255, 255); font-size: 16px; font-family: Arial; color: black; height: 425.521px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 22.3958px;\"\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; text-align: center; height: 22.3958px;\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px; height: 22.3958px;\"\u003eUSS-HDBV00023\u003c\/td\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; text-align: center; height: 22.3958px;\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px; height: 22.3958px;\"\u003eU.S. Solid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 44.7917px;\"\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eSize\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 44.7917px;\"\u003e1\"\u003c\/td\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eWiring Type\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 44.7917px;\"\u003eType F: ON\/OFF Type, Standard DC Polarity Reversal Control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 44.7917px;\"\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eValve Material\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 44.7917px;\"\u003e304SS\u003c\/td\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eBall Seal\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 44.7917px;\"\u003ePTFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 44.7917px;\"\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eOperating Time\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 44.7917px;\"\u003e8 Seconds\u003c\/td\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eWorking Voltage\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 44.7917px;\"\u003e24V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 22.3958px;\"\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 22.3958px;\"\u003eMax Power\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 22.3958px;\"\u003e9.5 W\u003c\/td\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 22.3958px;\"\u003eMax Torque\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 22.3958px;\"\u003e50 N m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 89.5833px;\"\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 89.5833px;\"\u003eMax Medium Pressure\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 89.5833px;\"\u003e1.6 Mpa\u003c\/td\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 89.5833px;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 89.5833px;\"\u003e-30°C to 180°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 44.7917px;\"\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eLife Expectancy\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 44.7917px;\"\u003e30,000 to 50,000 Cycles\u003c\/td\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eBore Type\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 44.7917px;\"\u003eFull port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 44.7917px;\"\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eThread Type\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 44.7917px;\"\u003eNPT\u003c\/td\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eOperating State\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 44.7917px;\"\u003eRemain in position\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 67.1875px;\"\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 67.1875px;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 67.1875px;\"\u003e-30°C to 60°C\u003c\/td\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 67.1875px;\"\u003eEnclosure Rating\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 67.1875px;\"\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eWARNINGS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"font-size: 16px; line-height: 26px; color: black; font-family: Arial; margin-bottom: 20px; padding-left: 20px;\"\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003ePower Failure Behavior:\u003c\/strong\u003e This valve remains in its current position during a power outage. It does not automatically return to a preset position.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eVoltage Match Required:\u003c\/strong\u003e Supply voltage must match the actuator rating exactly. Incorrect voltage may permanently damage the unit.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eDedicated Power Circuit:\u003c\/strong\u003e Each actuator requires its own fuse-protected power supply. Do not connect multiple actuators in parallel.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eDisconnect Power Before Service:\u003c\/strong\u003e Always disconnect power before wiring, maintenance, or using the manual override.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eIP65 Weather Resistant:\u003c\/strong\u003e Suitable for outdoor use, but additional protection is recommended for permanent outdoor installations.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eLow Power Consumption:\u003c\/strong\u003e Power is only used during opening and closing. No power is consumed when fully open or fully closed.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eProfessional Installation Recommended:\u003c\/strong\u003e Installation should be performed by qualified personnel familiar with electrical control systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"font-size: 16px; line-height: 26px; font-family: Arial; color: black; margin-bottom: 20px;\"\u003e\n\u003cp style=\"margin-bottom: 10px;\"\u003e\u003cstrong\u003e1: Can I manually operate the valve?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px; padding-left: 15px;\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes. The actuator features a manual override. We recommend manually cycling the valve before installation to verify smooth operation, and using the adjustment screws during commissioning to fine-tune open\/close positions.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 10px;\"\u003e\u003cstrong\u003e2: Can this valve be installed outdoors?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px; padding-left: 15px;\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes, depending on your model's IP rating. While our heavy-duty actuators are weather-resistant, we highly recommend using a protective cover or shelter for permanent outdoor installations to shield the unit from direct UV rays and ice buildup.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 10px;\"\u003e\u003cstrong\u003e3: Is this valve suitable for high-viscosity fluids or particulates?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px; padding-left: 15px;\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes, but with torque considerations. Our heavy-duty series is built for high-torque applications. However, extremely viscous mediums or large particulates will increase resistance. Ensure the operating torque remains within the actuator's rated capacity to avoid stalling.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 10px;\"\u003e\u003cstrong\u003e4: Is it normal for the actuator to feel hot during operation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px; padding-left: 15px;\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes, it is normal to feel warm during continuous cycling. The actuator includes built-in power-limiting features to prevent overheating under normal use. If the housing becomes too hot to touch, please check that you are not exceeding the recommended duty cycle or the ambient temperature limit (-30°C to +60°C).\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 10px;\"\u003e\u003cstrong\u003e5: Can I wire multiple actuators in parallel on the same circuit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px; padding-left: 15px;\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e No. Each motorized actuator must be installed on its own dedicated, fuse-protected circuit to ensure proper signal response and prevent electrical interference or damage.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 16px; margin-top: 25px;\"\u003eDownload user manual \u003ca href=\"http:\/\/file.ussolid.com\/content\/JFHDBV\/JFHDBV-%20Electric%20Actuated%20Ball%20Valve%20instruction%20manual.pdf\" rel=\"noopener\" style=\"color: #0066cc; text-decoration: underline;\" target=\"_blank\"\u003ehere\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mobile-only\" style=\"font-family: Arial, sans-serif; color: black;\"\u003e\n\u003ch3 style=\"margin-bottom: 20px; margin-top: 0;\"\u003e\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/%E6%9D%A1%E7%8A%B6%E5%9B%BE.jpg\" style=\"width: 100%; max-width: 100%; height: auto; display: block;\" alt=\"Product Introduction\"\u003e\u003c\/h3\u003e\n\u003cp style=\"font-size: 20px; font-family: Arial; text-align: left; margin-top: 0px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 15px; line-height: 24px; font-family: Arial; color: black; margin-bottom: 20px;\"\u003eThis premium flow control solution integrates a heavy-duty 3-piece stainless steel ball valve with a high-performance electric actuator. Engineered for reliability and precision, it provides a comprehensive hardware suite for automated systems, offering superior durability, seamless integration, and simplified maintenance in demanding industrial environments.\u003c\/p\u003e\n\u003cp style=\"font-size: 20px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"margin-bottom: 20px; text-align: center;\"\u003e\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/FEATURES.webp\" alt=\"\"\u003e\u003c\/div\u003e\n\u003cul style=\"font-size: 15px; line-height: 24px; color: black; font-family: Arial; margin-bottom: 20px; padding-left: 20px;\"\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003ePremium Material Construction:\u003c\/strong\u003e Crafted from high-grade 304 stainless steel, the valve body is highly resistant to corrosion, making it suitable for handling weak acids, weak alkalis, chemical solvents, and water.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eMaintenance-Friendly 3-Piece Design:\u003c\/strong\u003e The innovative 3-piece body construction allows for seamless in-line maintenance. Internal components can be easily cleaned or replaced without the need to disconnect the pipes, significantly reducing downtime and service costs.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eHigh-Pressure \u0026amp; Full-Bore Efficiency:\u003c\/strong\u003e Designed for maximum performance, the full-bore configuration guarantees minimal pressure drop, ensuring optimal flow capacity even in high-pressure systems.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eSmart Automation Ready:\u003c\/strong\u003e Equipped with integrated limit switches and position feedback, the actuator allows for seamless integration with PLC systems, enabling precise remote control, real-time monitoring, and full automation in complex industrial processes.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eHigh-Torque Reliability:\u003c\/strong\u003e Powered by a compact yet robust heavy-duty motor, the actuator delivers a steady torque of 50Nm, ensuring consistent full-port opening and reliable drop-tight sealing for every cycle.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eEnhanced Safety \u0026amp; Self-Locking:\u003c\/strong\u003e The actuator features an integrated self-locking mechanism to ensure valve stability and system integrity. Additionally, a built-in manual override port ensures safe, reliable intervention during power outages or emergencies.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eRugged Outdoor Durability:\u003c\/strong\u003e Engineered for the elements, the unit is encased in a powder-coated polyester aluminum housing, providing exceptional resistance to corrosion and harsh weather.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eAdvanced Circuitry Protection:\u003c\/strong\u003e To ensure long-term electrical reliability, the internal PCBA is treated with a protective sealant, effectively preventing damage from moisture, condensation, and short circuits.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size: 20px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px;\"\u003e\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/Application.png\" style=\"width: 100%; max-width: 100%; height: auto; display: block;\" alt=\"Applications\"\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 20px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eWIRING DIAGRAMS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; gap: 12px; margin-bottom: 20px;\"\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/Wiring-AB.jpg\" style=\"width: 100%; max-width: 100%; height: auto; display: block;\" alt=\"Wiring Diagram 1\"\u003e \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/Wiring-CD.jpg\" style=\"width: 100%; max-width: 100%; height: auto; display: block;\" alt=\"Wiring Diagram 2\"\u003e \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/Wiring-ef.jpg\" style=\"width: 100%; max-width: 100%; height: auto; display: block;\" alt=\"Type F: ON\/OFF Type, Standard DC Polarity Reversal Control\"\u003e \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/Wiring-IJ.jpg\" style=\"width: 100%; max-width: 100%; height: auto; display: block;\" alt=\"Wiring Diagram I\/J\"\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 20px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"width: 100%; overflow-x: auto; margin-bottom: 20px;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; background-color: rgb(255, 255, 255); font-size: 15px; font-family: Arial; color: black; height: 425.521px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 22.3958px;\"\u003e\n\u003cth style=\"width: 20%; padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; text-align: center; height: 22.3958px;\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 6px; height: 22.3958px;\"\u003eUSS-HDBV00023\u003c\/td\u003e\n\u003cth style=\"width: 20%; padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; text-align: center; height: 22.3958px;\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 6px; height: 22.3958px;\"\u003eU.S. Solid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 44.7917px;\"\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eSize\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 44.7917px;\"\u003e1\"\u003c\/td\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eWiring Type\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 44.7917px;\"\u003eType F: ON\/OFF Type, Standard DC Polarity Reversal Control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 44.7917px;\"\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eValve Material\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 44.7917px;\"\u003e304SS\u003c\/td\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eBall Seal\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 44.7917px;\"\u003ePTFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 44.7917px;\"\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eOperating Time\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 44.7917px;\"\u003e8 Seconds\u003c\/td\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eWorking Voltage\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 44.7917px;\"\u003e24V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 22.3958px;\"\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 22.3958px;\"\u003eMax Power\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 22.3958px;\"\u003e9.5 W\u003c\/td\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 22.3958px;\"\u003eMax Torque\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 22.3958px;\"\u003e50 N m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 89.5833px;\"\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 89.5833px;\"\u003eMax Medium Pressure\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 89.5833px;\"\u003e1.6 Mpa\u003c\/td\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 89.5833px;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 89.5833px;\"\u003e-30°C to 180°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 44.7917px;\"\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eLife Expectancy\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 44.7917px;\"\u003e30,000 to 50,000 Cycles\u003c\/td\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eBore Type\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 44.7917px;\"\u003eFull port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 44.7917px;\"\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eThread Type\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 44.7917px;\"\u003eNPT\u003c\/td\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eOperating State\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 44.7917px;\"\u003eRemain in position\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 67.1875px;\"\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 67.1875px;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 67.1875px;\"\u003e-30°C to 60°C\u003c\/td\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 67.1875px;\"\u003eEnclosure Rating\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 67.1875px;\"\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 20px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eWARNINGS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"font-size: 15px; line-height: 24px; color: black; font-family: Arial; margin-bottom: 20px; padding-left: 20px;\"\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003ePower Failure Behavior:\u003c\/strong\u003e This valve remains in its current position during a power outage. It does not automatically return to a preset position.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eVoltage Match Required:\u003c\/strong\u003e Supply voltage must match the actuator rating exactly. Incorrect voltage may permanently damage the unit.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eDedicated Power Circuit:\u003c\/strong\u003e Each actuator requires its own fuse-protected power supply. Do not connect multiple actuators in parallel.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eDisconnect Power Before Service:\u003c\/strong\u003e Always disconnect power before wiring, maintenance, or using the manual override.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eIP65 Weather Resistant:\u003c\/strong\u003e Suitable for outdoor use, but additional protection is recommended for permanent outdoor installations.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eLow Power Consumption:\u003c\/strong\u003e Power is only used during opening and closing. No power is consumed when fully open or fully closed.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eProfessional Installation Recommended:\u003c\/strong\u003e Installation should be performed by qualified personnel familiar with electrical control systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size: 20px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"font-size: 15px; line-height: 24px; font-family: Arial; color: black; margin-bottom: 20px;\"\u003e\n\u003cp style=\"margin-bottom: 10px;\"\u003e\u003cstrong\u003e1: Can I manually operate the valve?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px; padding-left: 15px;\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes. The actuator features a manual override. We recommend manually cycling the valve before installation to verify smooth operation, and using the adjustment screws during commissioning to fine-tune open\/close positions.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 10px;\"\u003e\u003cstrong\u003e2: Can this valve be installed outdoors?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px; padding-left: 15px;\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes, depending on your model's IP rating. While our heavy-duty actuators are weather-resistant, we highly recommend using a protective cover or shelter for permanent outdoor installations to shield the unit from direct UV rays and ice buildup.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 10px;\"\u003e\u003cstrong\u003e3: Is this valve suitable for high-viscosity fluids or particulates?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px; padding-left: 15px;\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes, but with torque considerations. Our heavy-duty series is built for high-torque applications. However, extremely viscous mediums or large particulates will increase resistance. Ensure the operating torque remains within the actuator's rated capacity to avoid stalling.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 10px;\"\u003e\u003cstrong\u003e4: Is it normal for the actuator to feel hot during operation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px; padding-left: 15px;\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes, it is normal to feel warm during continuous cycling. The actuator includes built-in power-limiting features to prevent overheating under normal use. If the housing becomes too hot to touch, please check that you are not exceeding the recommended duty cycle or the ambient temperature limit (-30°C to +60°C).\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 10px;\"\u003e\u003cstrong\u003e5: Can I wire multiple actuators in parallel on the same circuit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px; padding-left: 15px;\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e No. Each motorized actuator must be installed on its own dedicated, fuse-protected circuit to ensure proper signal response and prevent electrical interference or damage.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 15px; margin-top: 25px;\"\u003eDownload user manual \u003ca href=\"http:\/\/file.ussolid.com\/content\/JFHDBV\/JFHDBV-%20Electric%20Actuated%20Ball%20Valve%20instruction%20manual.pdf\" rel=\"noopener\" style=\"color: #0066cc; text-decoration: underline;\" target=\"_blank\"\u003ehere\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"U.S. Solid","offers":[{"title":"Default Title","offer_id":48808423194879,"sku":"JFHDBV00023","price":249.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/2_883e8a45-3a30-45cc-91f7-aeea426edccd.jpg?v=1784016103"},{"product_id":"1-1-4-electric-actuated-ball-valve-dc-24v-heavy-duty-3-piece-industrial-ball-valve-304ss-on-off-type-dry-contact","title":"1 1\/4\" Electric Actuated Ball Valve, DC 24V Heavy Duty 3-Piece Industrial Ball Valve,304SS, ON\/OFF Type, Dry Contact","description":"\u003cstyle\u003e\n  .mobile-only {\n    display: none;\n  }\n\n  .desktop-only img,\n  .mobile-only img {\n    max-width: 100%;\n    height: auto;\n  }\n\n  @media only screen and (max-width: 600px) {\n    .desktop-only {\n      display: none !important;\n    }\n\n    .mobile-only {\n      display: block !important;\n      font-family: Arial, sans-serif;\n      color: black;\n    }\n\n    .mobile-only table {\n      min-width: 620px;\n    }\n\n    .mobile-only ul {\n      padding-left: 18px !important;\n    }\n  }\n\n  @media only screen and (min-width: 601px) {\n    .desktop-only {\n      display: block !important;\n    }\n\n    .mobile-only {\n      display: none !important;\n    }\n  }\n\u003c\/style\u003e\n\u003cdiv style=\"font-family: Arial, sans-serif; color: black;\" class=\"desktop-only\"\u003e\n\u003ch3 style=\"margin-bottom: 20px; margin-top: 0;\"\u003e\u003cimg alt=\"Product Introduction\" style=\"width: 100%; max-width: 100%; height: auto; display: block;\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/%E6%9D%A1%E7%8A%B6%E5%9B%BE.jpg\"\u003e\u003c\/h3\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top: 0px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; line-height: 26px; font-family: Arial; color: black; margin-bottom: 20px;\"\u003eThis premium flow control solution integrates a heavy-duty 3-piece stainless steel ball valve with a high-performance electric actuator. Engineered for reliability and precision, it provides a comprehensive hardware suite for automated systems, offering superior durability, seamless integration, and simplified maintenance in demanding industrial environments.\u003c\/p\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"margin-bottom: 20px; text-align: center;\"\u003e\u003cimg alt=\"\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/FEATURES.webp\"\u003e\u003c\/div\u003e\n\u003cul style=\"font-size: 16px; line-height: 26px; color: black; font-family: Arial; margin-bottom: 20px; padding-left: 20px;\"\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003ePremium Material Construction:\u003c\/strong\u003e Crafted from high-grade 304 stainless steel, the valve body is highly resistant to corrosion, making it suitable for handling weak acids, weak alkalis, chemical solvents, and water.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eMaintenance-Friendly 3-Piece Design:\u003c\/strong\u003e The innovative 3-piece body construction allows for seamless in-line maintenance. Internal components can be easily cleaned or replaced without the need to disconnect the pipes, significantly reducing downtime and service costs.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eHigh-Pressure \u0026amp; Full-Bore Efficiency:\u003c\/strong\u003e Designed for maximum performance, the full-bore configuration guarantees minimal pressure drop, ensuring optimal flow capacity even in high-pressure systems.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eSmart Automation Ready:\u003c\/strong\u003e Equipped with integrated limit switches and position feedback, the actuator allows for seamless integration with PLC systems, enabling precise remote control, real-time monitoring, and full automation in complex industrial processes.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eHigh-Torque Reliability:\u003c\/strong\u003e Powered by a compact yet robust heavy-duty motor, the actuator delivers a steady torque of 50Nm, ensuring consistent full-port opening and reliable drop-tight sealing for every cycle.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eEnhanced Safety \u0026amp; Self-Locking:\u003c\/strong\u003e The actuator features an integrated self-locking mechanism to ensure valve stability and system integrity. Additionally, a built-in manual override port ensures safe, reliable intervention during power outages or emergencies.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eRugged Outdoor Durability:\u003c\/strong\u003e Engineered for the elements, the unit is encased in a powder-coated polyester aluminum housing, providing exceptional resistance to corrosion and harsh weather.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eAdvanced Circuitry Protection:\u003c\/strong\u003e To ensure long-term electrical reliability, the internal PCBA is treated with a protective sealant, effectively preventing damage from moisture, condensation, and short circuits.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px;\"\u003e\u003cimg alt=\"Applications\" style=\"width: 100%; max-width: 100%; height: auto; display: block;\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/Application.png\"\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eWIRING DIAGRAMS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"display: grid; grid-template-columns: repeat(2, minmax(0, 1fr)); gap: 15px; margin-bottom: 20px;\"\u003e\n\u003cdiv style=\"width: 100%; aspect-ratio: 1.42 \/ 1; display: flex; align-items: center; justify-content: center; overflow: hidden;\"\u003e\u003cimg alt=\"Wiring Diagram A\/B\" style=\"width: 100%; height: 100%; object-fit: contain; display: block;\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/Wiring-AB.jpg\"\u003e\u003c\/div\u003e \u003cdiv style=\"width: 100%; aspect-ratio: 1.42 \/ 1; display: flex; align-items: center; justify-content: center; overflow: hidden;\"\u003e\u003cimg alt=\"Wiring Diagram C\/D\" style=\"width: 100%; height: 100%; object-fit: contain; display: block;\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/Wiring-CD.jpg\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"width: 100%; aspect-ratio: 1.42 \/ 1; display: flex; align-items: center; justify-content: center; overflow: hidden;\"\u003e\u003cimg alt=\"Type F: ON\/OFF Type, Standard DC Polarity Reversal Control\" style=\"width: 100%; height: 100%; object-fit: contain; display: block;\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/Wiring-ef.jpg\"\u003e\u003c\/div\u003e \u003cdiv style=\"width: 100%; aspect-ratio: 1.42 \/ 1; display: flex; align-items: center; justify-content: center; overflow: hidden;\"\u003e\u003cimg alt=\"Wiring Diagram I\/J\" style=\"width: 100%; height: 100%; object-fit: contain; display: block;\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/Wiring-IJ.jpg\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"width: 100%; overflow-x: auto; margin-bottom: 20px;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; background-color: rgb(255, 255, 255); font-size: 16px; font-family: Arial; color: black; height: 425.521px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 22.3958px;\"\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; text-align: center; height: 22.3958px;\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px; height: 22.3958px;\"\u003eUSS-HDBV00024\u003c\/td\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; text-align: center; height: 22.3958px;\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px; height: 22.3958px;\"\u003eU.S. Solid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 44.7917px;\"\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eSize\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 44.7917px;\"\u003e1 1\/4\"\u003c\/td\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eWiring Type\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 44.7917px;\"\u003eType F: ON\/OFF Type, Standard DC Polarity Reversal Control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 44.7917px;\"\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eValve Material\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 44.7917px;\"\u003e304SS\u003c\/td\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eBall Seal\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 44.7917px;\"\u003ePTFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 44.7917px;\"\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eOperating Time\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 44.7917px;\"\u003e8 Seconds\u003c\/td\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eWorking Voltage\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 44.7917px;\"\u003e24V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 22.3958px;\"\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 22.3958px;\"\u003eMax Power\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 22.3958px;\"\u003e9.5 W\u003c\/td\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 22.3958px;\"\u003eMax Torque\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 22.3958px;\"\u003e50 N m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 89.5833px;\"\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 89.5833px;\"\u003eMax Medium Pressure\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 89.5833px;\"\u003e1.6 Mpa\u003c\/td\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 89.5833px;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 89.5833px;\"\u003e-30°C to 180°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 44.7917px;\"\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eLife Expectancy\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 44.7917px;\"\u003e30,000 to 50,000 Cycles\u003c\/td\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eBore Type\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 44.7917px;\"\u003eFull port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 44.7917px;\"\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eThread Type\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 44.7917px;\"\u003eNPT\u003c\/td\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eOperating State\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 44.7917px;\"\u003eRemain in position\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 67.1875px;\"\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 67.1875px;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 67.1875px;\"\u003e-30°C to 60°C\u003c\/td\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 67.1875px;\"\u003eEnclosure Rating\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 67.1875px;\"\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eWARNINGS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"font-size: 16px; line-height: 26px; color: black; font-family: Arial; margin-bottom: 20px; padding-left: 20px;\"\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003ePower Failure Behavior:\u003c\/strong\u003e This valve remains in its current position during a power outage. It does not automatically return to a preset position.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eVoltage Match Required:\u003c\/strong\u003e Supply voltage must match the actuator rating exactly. Incorrect voltage may permanently damage the unit.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eDedicated Power Circuit:\u003c\/strong\u003e Each actuator requires its own fuse-protected power supply. Do not connect multiple actuators in parallel.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eDisconnect Power Before Service:\u003c\/strong\u003e Always disconnect power before wiring, maintenance, or using the manual override.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eIP65 Weather Resistant:\u003c\/strong\u003e Suitable for outdoor use, but additional protection is recommended for permanent outdoor installations.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eLow Power Consumption:\u003c\/strong\u003e Power is only used during opening and closing. No power is consumed when fully open or fully closed.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eProfessional Installation Recommended:\u003c\/strong\u003e Installation should be performed by qualified personnel familiar with electrical control systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"font-size: 16px; line-height: 26px; font-family: Arial; color: black; margin-bottom: 20px;\"\u003e\n\u003cp style=\"margin-bottom: 10px;\"\u003e\u003cstrong\u003e1: Can I manually operate the valve?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px; padding-left: 15px;\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes. The actuator features a manual override. We recommend manually cycling the valve before installation to verify smooth operation, and using the adjustment screws during commissioning to fine-tune open\/close positions.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 10px;\"\u003e\u003cstrong\u003e2: Can this valve be installed outdoors?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px; padding-left: 15px;\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes, depending on your model's IP rating. While our heavy-duty actuators are weather-resistant, we highly recommend using a protective cover or shelter for permanent outdoor installations to shield the unit from direct UV rays and ice buildup.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 10px;\"\u003e\u003cstrong\u003e3: Is this valve suitable for high-viscosity fluids or particulates?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px; padding-left: 15px;\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes, but with torque considerations. Our heavy-duty series is built for high-torque applications. However, extremely viscous mediums or large particulates will increase resistance. Ensure the operating torque remains within the actuator's rated capacity to avoid stalling.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 10px;\"\u003e\u003cstrong\u003e4: Is it normal for the actuator to feel hot during operation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px; padding-left: 15px;\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes, it is normal to feel warm during continuous cycling. The actuator includes built-in power-limiting features to prevent overheating under normal use. If the housing becomes too hot to touch, please check that you are not exceeding the recommended duty cycle or the ambient temperature limit (-30°C to +60°C).\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 10px;\"\u003e\u003cstrong\u003e5: Can I wire multiple actuators in parallel on the same circuit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px; padding-left: 15px;\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e No. Each motorized actuator must be installed on its own dedicated, fuse-protected circuit to ensure proper signal response and prevent electrical interference or damage.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 16px; margin-top: 25px;\"\u003eDownload user manual \u003ca style=\"color: #0066cc; text-decoration: underline;\" rel=\"noopener\" href=\"http:\/\/file.ussolid.com\/content\/JFHDBV\/JFHDBV-%20Electric%20Actuated%20Ball%20Valve%20instruction%20manual.pdf\" target=\"_blank\"\u003ehere\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"font-family: Arial, sans-serif; color: black;\" class=\"mobile-only\"\u003e\n\u003ch3 style=\"margin-bottom: 20px; margin-top: 0;\"\u003e\u003cimg alt=\"Product Introduction\" style=\"width: 100%; max-width: 100%; height: auto; display: block;\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/%E6%9D%A1%E7%8A%B6%E5%9B%BE.jpg\"\u003e\u003c\/h3\u003e\n\u003cp style=\"font-size: 20px; font-family: Arial; text-align: left; margin-top: 0px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 15px; line-height: 24px; font-family: Arial; color: black; margin-bottom: 20px;\"\u003eThis premium flow control solution integrates a heavy-duty 3-piece stainless steel ball valve with a high-performance electric actuator. Engineered for reliability and precision, it provides a comprehensive hardware suite for automated systems, offering superior durability, seamless integration, and simplified maintenance in demanding industrial environments.\u003c\/p\u003e\n\u003cp style=\"font-size: 20px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"margin-bottom: 20px; text-align: center;\"\u003e\u003cimg alt=\"\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/FEATURES.webp\"\u003e\u003c\/div\u003e\n\u003cul style=\"font-size: 15px; line-height: 24px; color: black; font-family: Arial; margin-bottom: 20px; padding-left: 20px;\"\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003ePremium Material Construction:\u003c\/strong\u003e Crafted from high-grade 304 stainless steel, the valve body is highly resistant to corrosion, making it suitable for handling weak acids, weak alkalis, chemical solvents, and water.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eMaintenance-Friendly 3-Piece Design:\u003c\/strong\u003e The innovative 3-piece body construction allows for seamless in-line maintenance. Internal components can be easily cleaned or replaced without the need to disconnect the pipes, significantly reducing downtime and service costs.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eHigh-Pressure \u0026amp; Full-Bore Efficiency:\u003c\/strong\u003e Designed for maximum performance, the full-bore configuration guarantees minimal pressure drop, ensuring optimal flow capacity even in high-pressure systems.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eSmart Automation Ready:\u003c\/strong\u003e Equipped with integrated limit switches and position feedback, the actuator allows for seamless integration with PLC systems, enabling precise remote control, real-time monitoring, and full automation in complex industrial processes.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eHigh-Torque Reliability:\u003c\/strong\u003e Powered by a compact yet robust heavy-duty motor, the actuator delivers a steady torque of 50Nm, ensuring consistent full-port opening and reliable drop-tight sealing for every cycle.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eEnhanced Safety \u0026amp; Self-Locking:\u003c\/strong\u003e The actuator features an integrated self-locking mechanism to ensure valve stability and system integrity. Additionally, a built-in manual override port ensures safe, reliable intervention during power outages or emergencies.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eRugged Outdoor Durability:\u003c\/strong\u003e Engineered for the elements, the unit is encased in a powder-coated polyester aluminum housing, providing exceptional resistance to corrosion and harsh weather.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eAdvanced Circuitry Protection:\u003c\/strong\u003e To ensure long-term electrical reliability, the internal PCBA is treated with a protective sealant, effectively preventing damage from moisture, condensation, and short circuits.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size: 20px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px;\"\u003e\u003cimg alt=\"Applications\" style=\"width: 100%; max-width: 100%; height: auto; display: block;\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/Application.png\"\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 20px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eWIRING DIAGRAMS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; gap: 12px; margin-bottom: 20px;\"\u003e\n\u003cimg alt=\"Wiring Diagram 1\" style=\"width: 100%; max-width: 100%; height: auto; display: block;\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/Wiring-AB.jpg\"\u003e \u003cimg alt=\"Wiring Diagram 2\" style=\"width: 100%; max-width: 100%; height: auto; display: block;\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/Wiring-CD.jpg\"\u003e \u003cimg alt=\"Type F: ON\/OFF Type, Standard DC Polarity Reversal Control\" style=\"width: 100%; max-width: 100%; height: auto; display: block;\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/Wiring-ef.jpg\"\u003e \u003cimg alt=\"Wiring Diagram I\/J\" style=\"width: 100%; max-width: 100%; height: auto; display: block;\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/Wiring-IJ.jpg\"\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 20px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"width: 100%; overflow-x: auto; margin-bottom: 20px;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; background-color: rgb(255, 255, 255); font-size: 15px; font-family: Arial; color: black; height: 425.521px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 22.3958px;\"\u003e\n\u003cth style=\"width: 20%; padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; text-align: center; height: 22.3958px;\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 6px; height: 22.3958px;\"\u003eUSS-HDBV00024\u003c\/td\u003e\n\u003cth style=\"width: 20%; padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; text-align: center; height: 22.3958px;\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 6px; height: 22.3958px;\"\u003eU.S. Solid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 44.7917px;\"\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eSize\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 44.7917px;\"\u003e1 1\/4\"\u003c\/td\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eWiring Type\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 44.7917px;\"\u003eType F: ON\/OFF Type, Standard DC Polarity Reversal Control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 44.7917px;\"\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eValve Material\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 44.7917px;\"\u003e304SS\u003c\/td\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eBall Seal\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 44.7917px;\"\u003ePTFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 44.7917px;\"\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eOperating Time\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 44.7917px;\"\u003e8 Seconds\u003c\/td\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eWorking Voltage\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 44.7917px;\"\u003e24V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 22.3958px;\"\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 22.3958px;\"\u003eMax Power\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 22.3958px;\"\u003e9.5 W\u003c\/td\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 22.3958px;\"\u003eMax Torque\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 22.3958px;\"\u003e50 N m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 89.5833px;\"\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 89.5833px;\"\u003eMax Medium Pressure\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 89.5833px;\"\u003e1.6 Mpa\u003c\/td\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 89.5833px;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 89.5833px;\"\u003e-30°C to 180°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 44.7917px;\"\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eLife Expectancy\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 44.7917px;\"\u003e30,000 to 50,000 Cycles\u003c\/td\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eBore Type\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 44.7917px;\"\u003eFull port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 44.7917px;\"\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eThread Type\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 44.7917px;\"\u003eNPT\u003c\/td\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eOperating State\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 44.7917px;\"\u003eRemain in position\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 67.1875px;\"\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 67.1875px;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 67.1875px;\"\u003e-30°C to 60°C\u003c\/td\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 67.1875px;\"\u003eEnclosure Rating\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 67.1875px;\"\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 20px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eWARNINGS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"font-size: 15px; line-height: 24px; color: black; font-family: Arial; margin-bottom: 20px; padding-left: 20px;\"\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003ePower Failure Behavior:\u003c\/strong\u003e This valve remains in its current position during a power outage. It does not automatically return to a preset position.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eVoltage Match Required:\u003c\/strong\u003e Supply voltage must match the actuator rating exactly. Incorrect voltage may permanently damage the unit.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eDedicated Power Circuit:\u003c\/strong\u003e Each actuator requires its own fuse-protected power supply. Do not connect multiple actuators in parallel.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eDisconnect Power Before Service:\u003c\/strong\u003e Always disconnect power before wiring, maintenance, or using the manual override.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eIP65 Weather Resistant:\u003c\/strong\u003e Suitable for outdoor use, but additional protection is recommended for permanent outdoor installations.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eLow Power Consumption:\u003c\/strong\u003e Power is only used during opening and closing. No power is consumed when fully open or fully closed.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eProfessional Installation Recommended:\u003c\/strong\u003e Installation should be performed by qualified personnel familiar with electrical control systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size: 20px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"font-size: 15px; line-height: 24px; font-family: Arial; color: black; margin-bottom: 20px;\"\u003e\n\u003cp style=\"margin-bottom: 10px;\"\u003e\u003cstrong\u003e1: Can I manually operate the valve?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px; padding-left: 15px;\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes. The actuator features a manual override. We recommend manually cycling the valve before installation to verify smooth operation, and using the adjustment screws during commissioning to fine-tune open\/close positions.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 10px;\"\u003e\u003cstrong\u003e2: Can this valve be installed outdoors?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px; padding-left: 15px;\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes, depending on your model's IP rating. While our heavy-duty actuators are weather-resistant, we highly recommend using a protective cover or shelter for permanent outdoor installations to shield the unit from direct UV rays and ice buildup.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 10px;\"\u003e\u003cstrong\u003e3: Is this valve suitable for high-viscosity fluids or particulates?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px; padding-left: 15px;\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes, but with torque considerations. Our heavy-duty series is built for high-torque applications. However, extremely viscous mediums or large particulates will increase resistance. Ensure the operating torque remains within the actuator's rated capacity to avoid stalling.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 10px;\"\u003e\u003cstrong\u003e4: Is it normal for the actuator to feel hot during operation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px; padding-left: 15px;\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes, it is normal to feel warm during continuous cycling. The actuator includes built-in power-limiting features to prevent overheating under normal use. If the housing becomes too hot to touch, please check that you are not exceeding the recommended duty cycle or the ambient temperature limit (-30°C to +60°C).\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 10px;\"\u003e\u003cstrong\u003e5: Can I wire multiple actuators in parallel on the same circuit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px; padding-left: 15px;\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e No. Each motorized actuator must be installed on its own dedicated, fuse-protected circuit to ensure proper signal response and prevent electrical interference or damage.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 15px; margin-top: 25px;\"\u003eDownload user manual \u003ca style=\"color: #0066cc; text-decoration: underline;\" rel=\"noopener\" href=\"http:\/\/file.ussolid.com\/content\/JFHDBV\/JFHDBV-%20Electric%20Actuated%20Ball%20Valve%20instruction%20manual.pdf\" target=\"_blank\"\u003ehere\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"U.S. Solid","offers":[{"title":"Default Title","offer_id":48808440987903,"sku":"JFHDBV00024","price":259.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/2_cbb359e8-e170-42f8-9eaa-7de31651f018.jpg?v=1784016550"},{"product_id":"1-1-2-electric-actuated-ball-valve-dc-24v-heavy-duty-3-piece-industrial-ball-valve-304ss-on-off-type-dry-contact","title":"1 1\/2\" Electric Actuated Ball Valve, DC 24V  Heavy Duty 3-Piece Industrial Ball Valve,304SS, ON\/OFF Type, Dry Contact","description":"\u003cstyle\u003e\n  .mobile-only {\n    display: none;\n  }\n\n  .desktop-only img,\n  .mobile-only img {\n    max-width: 100%;\n    height: auto;\n  }\n\n  @media only screen and (max-width: 600px) {\n    .desktop-only {\n      display: none !important;\n    }\n\n    .mobile-only {\n      display: block !important;\n      font-family: Arial, sans-serif;\n      color: black;\n    }\n\n    .mobile-only table {\n      min-width: 620px;\n    }\n\n    .mobile-only ul {\n      padding-left: 18px !important;\n    }\n  }\n\n  @media only screen and (min-width: 601px) {\n    .desktop-only {\n      display: block !important;\n    }\n\n    .mobile-only {\n      display: none !important;\n    }\n  }\n\u003c\/style\u003e\n\u003cdiv class=\"desktop-only\" style=\"font-family: Arial, sans-serif; color: black;\"\u003e\n\u003ch3 style=\"margin-bottom: 20px; margin-top: 0;\"\u003e\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/%E6%9D%A1%E7%8A%B6%E5%9B%BE.jpg\" style=\"width: 100%; max-width: 100%; height: auto; display: block;\" alt=\"Product Introduction\"\u003e\u003c\/h3\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top: 0px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; line-height: 26px; font-family: Arial; color: black; margin-bottom: 20px;\"\u003eThis premium flow control solution integrates a heavy-duty 3-piece stainless steel ball valve with a high-performance electric actuator. Engineered for reliability and precision, it provides a comprehensive hardware suite for automated systems, offering superior durability, seamless integration, and simplified maintenance in demanding industrial environments.\u003c\/p\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"margin-bottom: 20px; text-align: center;\"\u003e\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/FEATURES.webp\" alt=\"\"\u003e\u003c\/div\u003e\n\u003cul style=\"font-size: 16px; line-height: 26px; color: black; font-family: Arial; margin-bottom: 20px; padding-left: 20px;\"\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003ePremium Material Construction:\u003c\/strong\u003e Crafted from high-grade 304 stainless steel, the valve body is highly resistant to corrosion, making it suitable for handling weak acids, weak alkalis, chemical solvents, and water.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eMaintenance-Friendly 3-Piece Design:\u003c\/strong\u003e The innovative 3-piece body construction allows for seamless in-line maintenance. Internal components can be easily cleaned or replaced without the need to disconnect the pipes, significantly reducing downtime and service costs.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eHigh-Pressure \u0026amp; Full-Bore Efficiency:\u003c\/strong\u003e Designed for maximum performance, the full-bore configuration guarantees minimal pressure drop, ensuring optimal flow capacity even in high-pressure systems.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eSmart Automation Ready:\u003c\/strong\u003e Equipped with integrated limit switches and position feedback, the actuator allows for seamless integration with PLC systems, enabling precise remote control, real-time monitoring, and full automation in complex industrial processes.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eHigh-Torque Reliability:\u003c\/strong\u003e Powered by a compact yet robust heavy-duty motor, the actuator delivers a steady torque of 100Nm, ensuring consistent full-port opening and reliable drop-tight sealing for every cycle.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eEnhanced Safety \u0026amp; Self-Locking:\u003c\/strong\u003e The actuator features an integrated self-locking mechanism to ensure valve stability and system integrity. Additionally, a built-in manual override port ensures safe, reliable intervention during power outages or emergencies.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eRugged Outdoor Durability:\u003c\/strong\u003e Engineered for the elements, the unit is encased in a powder-coated polyester aluminum housing, providing exceptional resistance to corrosion and harsh weather.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eAdvanced Circuitry Protection:\u003c\/strong\u003e To ensure long-term electrical reliability, the internal PCBA is treated with a protective sealant, effectively preventing damage from moisture, condensation, and short circuits.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px;\"\u003e\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/Application.png\" style=\"width: 100%; max-width: 100%; height: auto; display: block;\" alt=\"Applications\"\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eWIRING DIAGRAMS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"display: grid; grid-template-columns: repeat(2, minmax(0, 1fr)); gap: 15px; margin-bottom: 20px;\"\u003e\n\u003cdiv style=\"width: 100%; aspect-ratio: 1.42 \/ 1; display: flex; align-items: center; justify-content: center; overflow: hidden;\"\u003e\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/Wiring-AB.jpg\" style=\"width: 100%; height: 100%; object-fit: contain; display: block;\" alt=\"Wiring Diagram A\/B\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"width: 100%; aspect-ratio: 1.42 \/ 1; display: flex; align-items: center; justify-content: center; overflow: hidden;\"\u003e\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/Wiring-CD.jpg\" style=\"width: 100%; height: 100%; object-fit: contain; display: block;\" alt=\"Wiring Diagram C\/D\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"width: 100%; aspect-ratio: 1.42 \/ 1; display: flex; align-items: center; justify-content: center; overflow: hidden;\"\u003e\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/Wiring-ef.jpg\" style=\"width: 100%; height: 100%; object-fit: contain; display: block;\" alt=\"Type F: ON\/OFF Type, Standard DC Polarity Reversal Control\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"width: 100%; aspect-ratio: 1.42 \/ 1; display: flex; align-items: center; justify-content: center; overflow: hidden;\"\u003e\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/Wiring-IJ.jpg\" style=\"width: 100%; height: 100%; object-fit: contain; display: block;\" alt=\"Wiring Diagram I\/J\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"width: 100%; overflow-x: auto; margin-bottom: 20px;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; background-color: rgb(255, 255, 255); font-size: 16px; font-family: Arial; color: black; height: 425.521px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 22.3958px;\"\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; text-align: center; height: 22.3958px;\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px; height: 22.3958px;\"\u003eUSS-HDBV00025\u003c\/td\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; text-align: center; height: 22.3958px;\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px; height: 22.3958px;\"\u003eU.S. Solid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 44.7917px;\"\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eSize\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 44.7917px;\"\u003e1 1\/2\"\u003c\/td\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eWiring Type\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 44.7917px;\"\u003eType F: ON\/OFF Type, Standard DC Polarity Reversal Control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 44.7917px;\"\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eValve Material\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 44.7917px;\"\u003e304SS\u003c\/td\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eBall Seal\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 44.7917px;\"\u003ePTFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 44.7917px;\"\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eOperating Time\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 44.7917px;\"\u003e11 Seconds\u003c\/td\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eWorking Voltage\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 44.7917px;\"\u003e24V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 22.3958px;\"\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 22.3958px;\"\u003eMax Power\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 22.3958px;\"\u003e9 W\u003c\/td\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 22.3958px;\"\u003eMax Torque\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 22.3958px;\"\u003e100 N m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 89.5833px;\"\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 89.5833px;\"\u003eMax Medium Pressure\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 89.5833px;\"\u003e1.6 Mpa\u003c\/td\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 89.5833px;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 89.5833px;\"\u003e-30°C to 180°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 44.7917px;\"\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eLife Expectancy\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 44.7917px;\"\u003e30,000 to 50,000 Cycles\u003c\/td\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eBore Type\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 44.7917px;\"\u003eFull port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 44.7917px;\"\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eThread Type\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 44.7917px;\"\u003eNPT\u003c\/td\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eOperating State\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 44.7917px;\"\u003eRemain in position\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 67.1875px;\"\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 67.1875px;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 67.1875px;\"\u003e-30°C to 60°C\u003c\/td\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 67.1875px;\"\u003eEnclosure Rating\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 67.1875px;\"\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eWARNINGS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"font-size: 16px; line-height: 26px; color: black; font-family: Arial; margin-bottom: 20px; padding-left: 20px;\"\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003ePower Failure Behavior:\u003c\/strong\u003e This valve remains in its current position during a power outage. It does not automatically return to a preset position.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eVoltage Match Required:\u003c\/strong\u003e Supply voltage must match the actuator rating exactly. Incorrect voltage may permanently damage the unit.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eDedicated Power Circuit:\u003c\/strong\u003e Each actuator requires its own fuse-protected power supply. Do not connect multiple actuators in parallel.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eDisconnect Power Before Service:\u003c\/strong\u003e Always disconnect power before wiring, maintenance, or using the manual override.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eIP65 Weather Resistant:\u003c\/strong\u003e Suitable for outdoor use, but additional protection is recommended for permanent outdoor installations.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eLow Power Consumption:\u003c\/strong\u003e Power is only used during opening and closing. No power is consumed when fully open or fully closed.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eProfessional Installation Recommended:\u003c\/strong\u003e Installation should be performed by qualified personnel familiar with electrical control systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"font-size: 16px; line-height: 26px; font-family: Arial; color: black; margin-bottom: 20px;\"\u003e\n\u003cp style=\"margin-bottom: 10px;\"\u003e\u003cstrong\u003e1: Can I manually operate the valve?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px; padding-left: 15px;\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes. The actuator features a manual override. We recommend manually cycling the valve before installation to verify smooth operation, and using the adjustment screws during commissioning to fine-tune open\/close positions.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 10px;\"\u003e\u003cstrong\u003e2: Can this valve be installed outdoors?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px; padding-left: 15px;\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes, depending on your model's IP rating. While our heavy-duty actuators are weather-resistant, we highly recommend using a protective cover or shelter for permanent outdoor installations to shield the unit from direct UV rays and ice buildup.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 10px;\"\u003e\u003cstrong\u003e3: Is this valve suitable for high-viscosity fluids or particulates?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px; padding-left: 15px;\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes, but with torque considerations. Our heavy-duty series is built for high-torque applications. However, extremely viscous mediums or large particulates will increase resistance. Ensure the operating torque remains within the actuator's rated capacity to avoid stalling.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 10px;\"\u003e\u003cstrong\u003e4: Is it normal for the actuator to feel hot during operation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px; padding-left: 15px;\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes, it is normal to feel warm during continuous cycling. The actuator includes built-in power-limiting features to prevent overheating under normal use. If the housing becomes too hot to touch, please check that you are not exceeding the recommended duty cycle or the ambient temperature limit (-30°C to +60°C).\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 10px;\"\u003e\u003cstrong\u003e5: Can I wire multiple actuators in parallel on the same circuit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px; padding-left: 15px;\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e No. Each motorized actuator must be installed on its own dedicated, fuse-protected circuit to ensure proper signal response and prevent electrical interference or damage.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 16px; margin-top: 25px;\"\u003eDownload user manual \u003ca href=\"http:\/\/file.ussolid.com\/content\/JFHDBV\/JFHDBV-%20Electric%20Actuated%20Ball%20Valve%20instruction%20manual.pdf\" rel=\"noopener\" style=\"color: #0066cc; text-decoration: underline;\" target=\"_blank\"\u003ehere\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mobile-only\" style=\"font-family: Arial, sans-serif; color: black;\"\u003e\n\u003ch3 style=\"margin-bottom: 20px; margin-top: 0;\"\u003e\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/%E6%9D%A1%E7%8A%B6%E5%9B%BE.jpg\" style=\"width: 100%; max-width: 100%; height: auto; display: block;\" alt=\"Product Introduction\"\u003e\u003c\/h3\u003e\n\u003cp style=\"font-size: 20px; font-family: Arial; text-align: left; margin-top: 0px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 15px; line-height: 24px; font-family: Arial; color: black; margin-bottom: 20px;\"\u003eThis premium flow control solution integrates a heavy-duty 3-piece stainless steel ball valve with a high-performance electric actuator. Engineered for reliability and precision, it provides a comprehensive hardware suite for automated systems, offering superior durability, seamless integration, and simplified maintenance in demanding industrial environments.\u003c\/p\u003e\n\u003cp style=\"font-size: 20px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"margin-bottom: 20px; text-align: center;\"\u003e\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/FEATURES.webp\" alt=\"\"\u003e\u003c\/div\u003e\n\u003cul style=\"font-size: 15px; line-height: 24px; color: black; font-family: Arial; margin-bottom: 20px; padding-left: 20px;\"\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003ePremium Material Construction:\u003c\/strong\u003e Crafted from high-grade 304 stainless steel, the valve body is highly resistant to corrosion, making it suitable for handling weak acids, weak alkalis, chemical solvents, and water.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eMaintenance-Friendly 3-Piece Design:\u003c\/strong\u003e The innovative 3-piece body construction allows for seamless in-line maintenance. Internal components can be easily cleaned or replaced without the need to disconnect the pipes, significantly reducing downtime and service costs.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eHigh-Pressure \u0026amp; Full-Bore Efficiency:\u003c\/strong\u003e Designed for maximum performance, the full-bore configuration guarantees minimal pressure drop, ensuring optimal flow capacity even in high-pressure systems.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eSmart Automation Ready:\u003c\/strong\u003e Equipped with integrated limit switches and position feedback, the actuator allows for seamless integration with PLC systems, enabling precise remote control, real-time monitoring, and full automation in complex industrial processes.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eHigh-Torque Reliability:\u003c\/strong\u003e Powered by a compact yet robust heavy-duty motor, the actuator delivers a steady torque of 100Nm, ensuring consistent full-port opening and reliable drop-tight sealing for every cycle.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eEnhanced Safety \u0026amp; Self-Locking:\u003c\/strong\u003e The actuator features an integrated self-locking mechanism to ensure valve stability and system integrity. Additionally, a built-in manual override port ensures safe, reliable intervention during power outages or emergencies.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eRugged Outdoor Durability:\u003c\/strong\u003e Engineered for the elements, the unit is encased in a powder-coated polyester aluminum housing, providing exceptional resistance to corrosion and harsh weather.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eAdvanced Circuitry Protection:\u003c\/strong\u003e To ensure long-term electrical reliability, the internal PCBA is treated with a protective sealant, effectively preventing damage from moisture, condensation, and short circuits.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size: 20px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px;\"\u003e\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/Application.png\" style=\"width: 100%; max-width: 100%; height: auto; display: block;\" alt=\"Applications\"\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 20px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eWIRING DIAGRAMS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; gap: 12px; margin-bottom: 20px;\"\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/Wiring-AB.jpg\" style=\"width: 100%; max-width: 100%; height: auto; display: block;\" alt=\"Wiring Diagram 1\"\u003e \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/Wiring-CD.jpg\" style=\"width: 100%; max-width: 100%; height: auto; display: block;\" alt=\"Wiring Diagram 2\"\u003e \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/Wiring-ef.jpg\" style=\"width: 100%; max-width: 100%; height: auto; display: block;\" alt=\"Type F: ON\/OFF Type, Standard DC Polarity Reversal Control\"\u003e \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/Wiring-IJ.jpg\" style=\"width: 100%; max-width: 100%; height: auto; display: block;\" alt=\"Wiring Diagram I\/J\"\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 20px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"width: 100%; overflow-x: auto; margin-bottom: 20px;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; background-color: rgb(255, 255, 255); font-size: 15px; font-family: Arial; color: black; height: 425.521px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 22.3958px;\"\u003e\n\u003cth style=\"width: 20%; padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; text-align: center; height: 22.3958px;\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 6px; height: 22.3958px;\"\u003eUSS-HDBV00025\u003c\/td\u003e\n\u003cth style=\"width: 20%; padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; text-align: center; height: 22.3958px;\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 6px; height: 22.3958px;\"\u003eU.S. Solid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 44.7917px;\"\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eSize\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 44.7917px;\"\u003e1 1\/2\"\u003c\/td\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eWiring Type\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 44.7917px;\"\u003eType F: ON\/OFF Type, Standard DC Polarity Reversal Control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 44.7917px;\"\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eValve Material\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 44.7917px;\"\u003e304SS\u003c\/td\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eBall Seal\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 44.7917px;\"\u003ePTFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 44.7917px;\"\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eOperating Time\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 44.7917px;\"\u003e11 Seconds\u003c\/td\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eWorking Voltage\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 44.7917px;\"\u003e24V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 22.3958px;\"\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 22.3958px;\"\u003eMax Power\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 22.3958px;\"\u003e9 W\u003c\/td\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 22.3958px;\"\u003eMax Torque\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 22.3958px;\"\u003e100 N m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 89.5833px;\"\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 89.5833px;\"\u003eMax Medium Pressure\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 89.5833px;\"\u003e1.6 Mpa\u003c\/td\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 89.5833px;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 89.5833px;\"\u003e-30°C to 180°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 44.7917px;\"\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eLife Expectancy\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 44.7917px;\"\u003e30,000 to 50,000 Cycles\u003c\/td\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eBore Type\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 44.7917px;\"\u003eFull port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 44.7917px;\"\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eThread Type\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 44.7917px;\"\u003eNPT\u003c\/td\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eOperating State\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 44.7917px;\"\u003eRemain in position\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 67.1875px;\"\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 67.1875px;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 67.1875px;\"\u003e-30°C to 60°C\u003c\/td\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 67.1875px;\"\u003eEnclosure Rating\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 67.1875px;\"\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 20px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eWARNINGS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"font-size: 15px; line-height: 24px; color: black; font-family: Arial; margin-bottom: 20px; padding-left: 20px;\"\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003ePower Failure Behavior:\u003c\/strong\u003e This valve remains in its current position during a power outage. It does not automatically return to a preset position.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eVoltage Match Required:\u003c\/strong\u003e Supply voltage must match the actuator rating exactly. Incorrect voltage may permanently damage the unit.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eDedicated Power Circuit:\u003c\/strong\u003e Each actuator requires its own fuse-protected power supply. Do not connect multiple actuators in parallel.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eDisconnect Power Before Service:\u003c\/strong\u003e Always disconnect power before wiring, maintenance, or using the manual override.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eIP65 Weather Resistant:\u003c\/strong\u003e Suitable for outdoor use, but additional protection is recommended for permanent outdoor installations.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eLow Power Consumption:\u003c\/strong\u003e Power is only used during opening and closing. No power is consumed when fully open or fully closed.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eProfessional Installation Recommended:\u003c\/strong\u003e Installation should be performed by qualified personnel familiar with electrical control systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size: 20px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"font-size: 15px; line-height: 24px; font-family: Arial; color: black; margin-bottom: 20px;\"\u003e\n\u003cp style=\"margin-bottom: 10px;\"\u003e\u003cstrong\u003e1: Can I manually operate the valve?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px; padding-left: 15px;\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes. The actuator features a manual override. We recommend manually cycling the valve before installation to verify smooth operation, and using the adjustment screws during commissioning to fine-tune open\/close positions.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 10px;\"\u003e\u003cstrong\u003e2: Can this valve be installed outdoors?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px; padding-left: 15px;\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes, depending on your model's IP rating. While our heavy-duty actuators are weather-resistant, we highly recommend using a protective cover or shelter for permanent outdoor installations to shield the unit from direct UV rays and ice buildup.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 10px;\"\u003e\u003cstrong\u003e3: Is this valve suitable for high-viscosity fluids or particulates?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px; padding-left: 15px;\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes, but with torque considerations. Our heavy-duty series is built for high-torque applications. However, extremely viscous mediums or large particulates will increase resistance. Ensure the operating torque remains within the actuator's rated capacity to avoid stalling.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 10px;\"\u003e\u003cstrong\u003e4: Is it normal for the actuator to feel hot during operation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px; padding-left: 15px;\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes, it is normal to feel warm during continuous cycling. The actuator includes built-in power-limiting features to prevent overheating under normal use. If the housing becomes too hot to touch, please check that you are not exceeding the recommended duty cycle or the ambient temperature limit (-30°C to +60°C).\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 10px;\"\u003e\u003cstrong\u003e5: Can I wire multiple actuators in parallel on the same circuit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px; padding-left: 15px;\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e No. Each motorized actuator must be installed on its own dedicated, fuse-protected circuit to ensure proper signal response and prevent electrical interference or damage.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 15px; margin-top: 25px;\"\u003eDownload user manual \u003ca href=\"http:\/\/file.ussolid.com\/content\/JFHDBV\/JFHDBV-%20Electric%20Actuated%20Ball%20Valve%20instruction%20manual.pdf\" rel=\"noopener\" style=\"color: #0066cc; text-decoration: underline;\" target=\"_blank\"\u003ehere\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"U.S. Solid","offers":[{"title":"Default Title","offer_id":48819515293951,"sku":"JFHDBV00025","price":359.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/2_53f41f21-2ef0-4d72-a3a0-4d429293e98a.jpg?v=1784017075"},{"product_id":"2-electric-actuated-ball-valve-dc-24v-heavy-duty-3-piece-industrial-ball-valve-304ss-on-off-type-dry-contact","title":"2\" Electric Actuated Ball Valve, DC 24V Heavy Duty 3-Piece Industrial Ball Valve,304SS, ON\/OFF Type, Dry Contact","description":"\u003cstyle\u003e\n  .mobile-only {\n    display: none;\n  }\n\n  .desktop-only img,\n  .mobile-only img {\n    max-width: 100%;\n    height: auto;\n  }\n\n  @media only screen and (max-width: 600px) {\n    .desktop-only {\n      display: none !important;\n    }\n\n    .mobile-only {\n      display: block !important;\n      font-family: Arial, sans-serif;\n      color: black;\n    }\n\n    .mobile-only table {\n      min-width: 620px;\n    }\n\n    .mobile-only ul {\n      padding-left: 18px !important;\n    }\n  }\n\n  @media only screen and (min-width: 601px) {\n    .desktop-only {\n      display: block !important;\n    }\n\n    .mobile-only {\n      display: none !important;\n    }\n  }\n\u003c\/style\u003e\n\u003cdiv class=\"desktop-only\" style=\"font-family: Arial, sans-serif; color: black;\"\u003e\n\u003ch3 style=\"margin-bottom: 20px; margin-top: 0;\"\u003e\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/%E6%9D%A1%E7%8A%B6%E5%9B%BE.jpg\" style=\"width: 100%; max-width: 100%; height: auto; display: block;\" alt=\"Product Introduction\"\u003e\u003c\/h3\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top: 0px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; line-height: 26px; font-family: Arial; color: black; margin-bottom: 20px;\"\u003eThis premium flow control solution integrates a heavy-duty 3-piece stainless steel ball valve with a high-performance electric actuator. Engineered for reliability and precision, it provides a comprehensive hardware suite for automated systems, offering superior durability, seamless integration, and simplified maintenance in demanding industrial environments.\u003c\/p\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"margin-bottom: 20px; text-align: center;\"\u003e\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/FEATURES.webp\" alt=\"\"\u003e\u003c\/div\u003e\n\u003cul style=\"font-size: 16px; line-height: 26px; color: black; font-family: Arial; margin-bottom: 20px; padding-left: 20px;\"\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003ePremium Material Construction:\u003c\/strong\u003e Crafted from high-grade 304 stainless steel, the valve body is highly resistant to corrosion, making it suitable for handling weak acids, weak alkalis, chemical solvents, and water.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eMaintenance-Friendly 3-Piece Design:\u003c\/strong\u003e The innovative 3-piece body construction allows for seamless in-line maintenance. Internal components can be easily cleaned or replaced without the need to disconnect the pipes, significantly reducing downtime and service costs.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eHigh-Pressure \u0026amp; Full-Bore Efficiency:\u003c\/strong\u003e Designed for maximum performance, the full-bore configuration guarantees minimal pressure drop, ensuring optimal flow capacity even in high-pressure systems.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eSmart Automation Ready:\u003c\/strong\u003e Equipped with integrated limit switches and position feedback, the actuator allows for seamless integration with PLC systems, enabling precise remote control, real-time monitoring, and full automation in complex industrial processes.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eHigh-Torque Reliability:\u003c\/strong\u003e Powered by a compact yet robust heavy-duty motor, the actuator delivers a steady torque of 100Nm, ensuring consistent full-port opening and reliable drop-tight sealing for every cycle.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eEnhanced Safety \u0026amp; Self-Locking:\u003c\/strong\u003e The actuator features an integrated self-locking mechanism to ensure valve stability and system integrity. Additionally, a built-in manual override port ensures safe, reliable intervention during power outages or emergencies.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eRugged Outdoor Durability:\u003c\/strong\u003e Engineered for the elements, the unit is encased in a powder-coated polyester aluminum housing, providing exceptional resistance to corrosion and harsh weather.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eAdvanced Circuitry Protection:\u003c\/strong\u003e To ensure long-term electrical reliability, the internal PCBA is treated with a protective sealant, effectively preventing damage from moisture, condensation, and short circuits.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px;\"\u003e\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/Application.png\" style=\"width: 100%; max-width: 100%; height: auto; display: block;\" alt=\"Applications\"\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eWIRING DIAGRAMS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"display: grid; grid-template-columns: repeat(2, minmax(0, 1fr)); gap: 15px; margin-bottom: 20px;\"\u003e\n\u003cdiv style=\"width: 100%; aspect-ratio: 1.42 \/ 1; display: flex; align-items: center; justify-content: center; overflow: hidden;\"\u003e\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/Wiring-AB.jpg\" style=\"width: 100%; height: 100%; object-fit: contain; display: block;\" alt=\"Wiring Diagram A\/B\"\u003e\u003c\/div\u003e \u003cdiv style=\"width: 100%; aspect-ratio: 1.42 \/ 1; display: flex; align-items: center; justify-content: center; overflow: hidden;\"\u003e\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/Wiring-CD.jpg\" style=\"width: 100%; height: 100%; object-fit: contain; display: block;\" alt=\"Wiring Diagram C\/D\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"width: 100%; aspect-ratio: 1.42 \/ 1; display: flex; align-items: center; justify-content: center; overflow: hidden;\"\u003e\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/Wiring-ef.jpg\" style=\"width: 100%; height: 100%; object-fit: contain; display: block;\" alt=\"Type F: ON\/OFF Type, Standard DC Polarity Reversal Control\"\u003e\u003c\/div\u003e \u003cdiv style=\"width: 100%; aspect-ratio: 1.42 \/ 1; display: flex; align-items: center; justify-content: center; overflow: hidden;\"\u003e\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/Wiring-IJ.jpg\" style=\"width: 100%; height: 100%; object-fit: contain; display: block;\" alt=\"Wiring Diagram I\/J\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"width: 100%; overflow-x: auto; margin-bottom: 20px;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; background-color: rgb(255, 255, 255); font-size: 16px; font-family: Arial; color: black; height: 425.521px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 22.3958px;\"\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; text-align: center; height: 22.3958px;\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px; height: 22.3958px;\"\u003eUSS-HDBV00026\u003c\/td\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; text-align: center; height: 22.3958px;\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px; height: 22.3958px;\"\u003eU.S. Solid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 44.7917px;\"\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eSize\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 44.7917px;\"\u003e2\"\u003c\/td\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eWiring Type\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 44.7917px;\"\u003eType F: ON\/OFF Type, Standard DC Polarity Reversal Control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 44.7917px;\"\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eValve Material\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 44.7917px;\"\u003e304SS\u003c\/td\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eBall Seal\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 44.7917px;\"\u003ePTFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 44.7917px;\"\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eOperating Time\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 44.7917px;\"\u003e11 Seconds\u003c\/td\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eWorking Voltage\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 44.7917px;\"\u003e24V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 22.3958px;\"\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 22.3958px;\"\u003eMax Power\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 22.3958px;\"\u003e9 W\u003c\/td\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 22.3958px;\"\u003eMax Torque\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 22.3958px;\"\u003e100 N m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 89.5833px;\"\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 89.5833px;\"\u003eMax Medium Pressure\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 89.5833px;\"\u003e1.6 Mpa\u003c\/td\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 89.5833px;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 89.5833px;\"\u003e-30°C to 180°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 44.7917px;\"\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eLife Expectancy\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 44.7917px;\"\u003e30,000 to 50,000 Cycles\u003c\/td\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eBore Type\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 44.7917px;\"\u003eFull port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 44.7917px;\"\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eThread Type\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 44.7917px;\"\u003eNPT\u003c\/td\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eOperating State\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 44.7917px;\"\u003eRemain in position\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 67.1875px;\"\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 67.1875px;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 67.1875px;\"\u003e-30°C to 60°C\u003c\/td\u003e\n\u003cth style=\"padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; height: 67.1875px;\"\u003eEnclosure Rating\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; height: 67.1875px;\"\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eWARNINGS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"font-size: 16px; line-height: 26px; color: black; font-family: Arial; margin-bottom: 20px; padding-left: 20px;\"\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003ePower Failure Behavior:\u003c\/strong\u003e This valve remains in its current position during a power outage. It does not automatically return to a preset position.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eVoltage Match Required:\u003c\/strong\u003e Supply voltage must match the actuator rating exactly. Incorrect voltage may permanently damage the unit.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eDedicated Power Circuit:\u003c\/strong\u003e Each actuator requires its own fuse-protected power supply. Do not connect multiple actuators in parallel.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eDisconnect Power Before Service:\u003c\/strong\u003e Always disconnect power before wiring, maintenance, or using the manual override.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eIP65 Weather Resistant:\u003c\/strong\u003e Suitable for outdoor use, but additional protection is recommended for permanent outdoor installations.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eLow Power Consumption:\u003c\/strong\u003e Power is only used during opening and closing. No power is consumed when fully open or fully closed.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eProfessional Installation Recommended:\u003c\/strong\u003e Installation should be performed by qualified personnel familiar with electrical control systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"font-size: 16px; line-height: 26px; font-family: Arial; color: black; margin-bottom: 20px;\"\u003e\n\u003cp style=\"margin-bottom: 10px;\"\u003e\u003cstrong\u003e1: Can I manually operate the valve?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px; padding-left: 15px;\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes. The actuator features a manual override. We recommend manually cycling the valve before installation to verify smooth operation, and using the adjustment screws during commissioning to fine-tune open\/close positions.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 10px;\"\u003e\u003cstrong\u003e2: Can this valve be installed outdoors?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px; padding-left: 15px;\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes, depending on your model's IP rating. While our heavy-duty actuators are weather-resistant, we highly recommend using a protective cover or shelter for permanent outdoor installations to shield the unit from direct UV rays and ice buildup.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 10px;\"\u003e\u003cstrong\u003e3: Is this valve suitable for high-viscosity fluids or particulates?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px; padding-left: 15px;\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes, but with torque considerations. Our heavy-duty series is built for high-torque applications. However, extremely viscous mediums or large particulates will increase resistance. Ensure the operating torque remains within the actuator's rated capacity to avoid stalling.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 10px;\"\u003e\u003cstrong\u003e4: Is it normal for the actuator to feel hot during operation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px; padding-left: 15px;\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes, it is normal to feel warm during continuous cycling. The actuator includes built-in power-limiting features to prevent overheating under normal use. If the housing becomes too hot to touch, please check that you are not exceeding the recommended duty cycle or the ambient temperature limit (-30°C to +60°C).\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 10px;\"\u003e\u003cstrong\u003e5: Can I wire multiple actuators in parallel on the same circuit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px; padding-left: 15px;\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e No. Each motorized actuator must be installed on its own dedicated, fuse-protected circuit to ensure proper signal response and prevent electrical interference or damage.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 16px; margin-top: 25px;\"\u003eDownload user manual \u003ca href=\"http:\/\/file.ussolid.com\/content\/JFHDBV\/JFHDBV-%20Electric%20Actuated%20Ball%20Valve%20instruction%20manual.pdf\" rel=\"noopener\" style=\"color: #0066cc; text-decoration: underline;\" target=\"_blank\"\u003ehere\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mobile-only\" style=\"font-family: Arial, sans-serif; color: black;\"\u003e\n\u003ch3 style=\"margin-bottom: 20px; margin-top: 0;\"\u003e\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/%E6%9D%A1%E7%8A%B6%E5%9B%BE.jpg\" style=\"width: 100%; max-width: 100%; height: auto; display: block;\" alt=\"Product Introduction\"\u003e\u003c\/h3\u003e\n\u003cp style=\"font-size: 20px; font-family: Arial; text-align: left; margin-top: 0px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 15px; line-height: 24px; font-family: Arial; color: black; margin-bottom: 20px;\"\u003eThis premium flow control solution integrates a heavy-duty 3-piece stainless steel ball valve with a high-performance electric actuator. Engineered for reliability and precision, it provides a comprehensive hardware suite for automated systems, offering superior durability, seamless integration, and simplified maintenance in demanding industrial environments.\u003c\/p\u003e\n\u003cp style=\"font-size: 20px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"margin-bottom: 20px; text-align: center;\"\u003e\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/FEATURES.webp\" alt=\"\"\u003e\u003c\/div\u003e\n\u003cul style=\"font-size: 15px; line-height: 24px; color: black; font-family: Arial; margin-bottom: 20px; padding-left: 20px;\"\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003ePremium Material Construction:\u003c\/strong\u003e Crafted from high-grade 304 stainless steel, the valve body is highly resistant to corrosion, making it suitable for handling weak acids, weak alkalis, chemical solvents, and water.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eMaintenance-Friendly 3-Piece Design:\u003c\/strong\u003e The innovative 3-piece body construction allows for seamless in-line maintenance. Internal components can be easily cleaned or replaced without the need to disconnect the pipes, significantly reducing downtime and service costs.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eHigh-Pressure \u0026amp; Full-Bore Efficiency:\u003c\/strong\u003e Designed for maximum performance, the full-bore configuration guarantees minimal pressure drop, ensuring optimal flow capacity even in high-pressure systems.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eSmart Automation Ready:\u003c\/strong\u003e Equipped with integrated limit switches and position feedback, the actuator allows for seamless integration with PLC systems, enabling precise remote control, real-time monitoring, and full automation in complex industrial processes.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eHigh-Torque Reliability:\u003c\/strong\u003e Powered by a compact yet robust heavy-duty motor, the actuator delivers a steady torque of 100Nm, ensuring consistent full-port opening and reliable drop-tight sealing for every cycle.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eEnhanced Safety \u0026amp; Self-Locking:\u003c\/strong\u003e The actuator features an integrated self-locking mechanism to ensure valve stability and system integrity. Additionally, a built-in manual override port ensures safe, reliable intervention during power outages or emergencies.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eRugged Outdoor Durability:\u003c\/strong\u003e Engineered for the elements, the unit is encased in a powder-coated polyester aluminum housing, providing exceptional resistance to corrosion and harsh weather.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eAdvanced Circuitry Protection:\u003c\/strong\u003e To ensure long-term electrical reliability, the internal PCBA is treated with a protective sealant, effectively preventing damage from moisture, condensation, and short circuits.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size: 20px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px;\"\u003e\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/Application.png\" style=\"width: 100%; max-width: 100%; height: auto; display: block;\" alt=\"Applications\"\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 20px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eWIRING DIAGRAMS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; gap: 12px; margin-bottom: 20px;\"\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/Wiring-AB.jpg\" style=\"width: 100%; max-width: 100%; height: auto; display: block;\" alt=\"Wiring Diagram 1\"\u003e \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/Wiring-CD.jpg\" style=\"width: 100%; max-width: 100%; height: auto; display: block;\" alt=\"Wiring Diagram 2\"\u003e \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/Wiring-ef.jpg\" style=\"width: 100%; max-width: 100%; height: auto; display: block;\" alt=\"Type F: ON\/OFF Type, Standard DC Polarity Reversal Control\"\u003e \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/Wiring-IJ.jpg\" style=\"width: 100%; max-width: 100%; height: auto; display: block;\" alt=\"Wiring Diagram I\/J\"\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 20px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"width: 100%; overflow-x: auto; margin-bottom: 20px;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; background-color: rgb(255, 255, 255); font-size: 15px; font-family: Arial; color: black; height: 425.521px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 22.3958px;\"\u003e\n\u003cth style=\"width: 20%; padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; text-align: center; height: 22.3958px;\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 6px; height: 22.3958px;\"\u003eUSS-HDBV00026\u003c\/td\u003e\n\u003cth style=\"width: 20%; padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; text-align: center; height: 22.3958px;\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 6px; height: 22.3958px;\"\u003eU.S. Solid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 44.7917px;\"\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eSize\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 44.7917px;\"\u003e2\"\u003c\/td\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eWiring Type\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 44.7917px;\"\u003eType F: ON\/OFF Type, Standard DC Polarity Reversal Control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 44.7917px;\"\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eValve Material\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 44.7917px;\"\u003e304SS\u003c\/td\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eBall Seal\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 44.7917px;\"\u003ePTFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 44.7917px;\"\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eOperating Time\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 44.7917px;\"\u003e11 Seconds\u003c\/td\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eWorking Voltage\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 44.7917px;\"\u003e24V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 22.3958px;\"\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 22.3958px;\"\u003eMax Power\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 22.3958px;\"\u003e9 W\u003c\/td\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 22.3958px;\"\u003eMax Torque\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 22.3958px;\"\u003e100 N m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 89.5833px;\"\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 89.5833px;\"\u003eMax Medium Pressure\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 89.5833px;\"\u003e1.6 Mpa\u003c\/td\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 89.5833px;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 89.5833px;\"\u003e-30°C to 180°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 44.7917px;\"\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eLife Expectancy\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 44.7917px;\"\u003e30,000 to 50,000 Cycles\u003c\/td\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eBore Type\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 44.7917px;\"\u003eFull port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 44.7917px;\"\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eThread Type\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 44.7917px;\"\u003eNPT\u003c\/td\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 44.7917px;\"\u003eOperating State\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 44.7917px;\"\u003eRemain in position\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed rgb(0, 0, 0); height: 67.1875px;\"\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 67.1875px;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 67.1875px;\"\u003e-30°C to 60°C\u003c\/td\u003e\n\u003cth style=\"padding: 6px; background-color: rgb(240, 240, 240); font-weight: bold; height: 67.1875px;\"\u003eEnclosure Rating\u003c\/th\u003e\n\u003ctd style=\"padding: 6px; height: 67.1875px;\"\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 20px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eWARNINGS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"font-size: 15px; line-height: 24px; color: black; font-family: Arial; margin-bottom: 20px; padding-left: 20px;\"\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003ePower Failure Behavior:\u003c\/strong\u003e This valve remains in its current position during a power outage. It does not automatically return to a preset position.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eVoltage Match Required:\u003c\/strong\u003e Supply voltage must match the actuator rating exactly. Incorrect voltage may permanently damage the unit.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eDedicated Power Circuit:\u003c\/strong\u003e Each actuator requires its own fuse-protected power supply. Do not connect multiple actuators in parallel.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eDisconnect Power Before Service:\u003c\/strong\u003e Always disconnect power before wiring, maintenance, or using the manual override.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eIP65 Weather Resistant:\u003c\/strong\u003e Suitable for outdoor use, but additional protection is recommended for permanent outdoor installations.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eLow Power Consumption:\u003c\/strong\u003e Power is only used during opening and closing. No power is consumed when fully open or fully closed.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eProfessional Installation Recommended:\u003c\/strong\u003e Installation should be performed by qualified personnel familiar with electrical control systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size: 20px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"font-size: 15px; line-height: 24px; font-family: Arial; color: black; margin-bottom: 20px;\"\u003e\n\u003cp style=\"margin-bottom: 10px;\"\u003e\u003cstrong\u003e1: Can I manually operate the valve?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px; padding-left: 15px;\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes. The actuator features a manual override. We recommend manually cycling the valve before installation to verify smooth operation, and using the adjustment screws during commissioning to fine-tune open\/close positions.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 10px;\"\u003e\u003cstrong\u003e2: Can this valve be installed outdoors?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px; padding-left: 15px;\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes, depending on your model's IP rating. While our heavy-duty actuators are weather-resistant, we highly recommend using a protective cover or shelter for permanent outdoor installations to shield the unit from direct UV rays and ice buildup.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 10px;\"\u003e\u003cstrong\u003e3: Is this valve suitable for high-viscosity fluids or particulates?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px; padding-left: 15px;\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes, but with torque considerations. Our heavy-duty series is built for high-torque applications. However, extremely viscous mediums or large particulates will increase resistance. Ensure the operating torque remains within the actuator's rated capacity to avoid stalling.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 10px;\"\u003e\u003cstrong\u003e4: Is it normal for the actuator to feel hot during operation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px; padding-left: 15px;\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes, it is normal to feel warm during continuous cycling. The actuator includes built-in power-limiting features to prevent overheating under normal use. If the housing becomes too hot to touch, please check that you are not exceeding the recommended duty cycle or the ambient temperature limit (-30°C to +60°C).\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 10px;\"\u003e\u003cstrong\u003e5: Can I wire multiple actuators in parallel on the same circuit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px; padding-left: 15px;\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e No. Each motorized actuator must be installed on its own dedicated, fuse-protected circuit to ensure proper signal response and prevent electrical interference or damage.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 15px; margin-top: 25px;\"\u003eDownload user manual \u003ca href=\"http:\/\/file.ussolid.com\/content\/JFHDBV\/JFHDBV-%20Electric%20Actuated%20Ball%20Valve%20instruction%20manual.pdf\" rel=\"noopener\" style=\"color: #0066cc; text-decoration: underline;\" target=\"_blank\"\u003ehere\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"U.S. Solid","offers":[{"title":"Default Title","offer_id":48819538395391,"sku":"JFHDBV00026","price":409.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/2_83fdba60-e579-428d-96e0-95663220614e.jpg?v=1784017419"},{"product_id":"1-2-modulating-electric-ball-valve-110v-ac-heavy-duty-3-piece-304-ss-industrial-ball-valve-4-20ma-proportional-control-with-position-feedback","title":"1\/2\" Modulating Electric Ball Valve, 110V AC Heavy Duty 3-Piece 304 SS Industrial Ball Valve, 4-20mA Proportional Control with Position Feedback","description":"\u003cstyle\u003e.bv-detail{font-family:Arial,sans-serif;color:#000;line-height:1.62}.bv-detail .desktop-img{display:block}.bv-detail .mobile-img{display:none}.bv-detail img{width:100%;max-width:100%;height:auto;display:block}.bv-detail h2{font-size:22px;font-weight:700;margin:25px 0 10px}.bv-detail p,.bv-detail li{font-size:16px}.bv-detail .image-pair{margin:0 0 20px}.bv-detail .wiring-grid{display:flex;flex-wrap:wrap;gap:15px;margin-bottom:20px}.bv-detail .wiring-card{flex:1;min-width:280px}.bv-detail .wiring-card h3{text-align:center;font-size:16px;margin:0 0 10px}.bv-detail .control-callout{margin:0 0 24px;padding:18px 20px 8px;border-left:4px solid #78b72a;background:#f4f8ee}.bv-detail .control-callout h3{margin:0 0 12px;font-size:17px;color:#16220c}.bv-detail .control-callout ul{margin:0;padding-left:20px}.bv-detail .control-callout li{margin-bottom:9px}.bv-detail .spec-scroll{width:100%;overflow-x:auto;overflow-y:hidden;margin:0 0 20px;-webkit-overflow-scrolling:touch}.bv-detail .spec-scroll table{width:100%;border-collapse:collapse;background:#fff;margin:0}.bv-detail tr{border-bottom:1px dashed #000}.bv-detail th,.bv-detail td{padding:10px;text-align:left;font-size:15px;vertical-align:top}.bv-detail th{width:20%;background:#f0f0f0;font-weight:bold}.bv-detail .faq-q{font-weight:bold;margin:16px 0 5px}.bv-detail .faq-a{margin:0 0 16px;padding-left:15px}.bv-detail a{color:#0066cc;text-decoration:underline}@media(max-width:600px){.bv-detail .desktop-img{display:none!important}.bv-detail .mobile-img{display:block!important}.bv-detail h2{font-size:20px;font-weight:700}.bv-detail p,.bv-detail li{font-size:15px}.bv-detail .wiring-grid{display:block}.bv-detail .wiring-card{margin-bottom:15px}.bv-detail .control-callout{padding:15px 14px 6px}.bv-detail .control-callout h3{font-size:16px}.bv-detail .spec-scroll table{min-width:680px}.bv-detail th,.bv-detail td{padding:8px 9px;font-size:14px;white-space:normal}}\u003c\/style\u003e\n\u003cdiv class=\"bv-detail\"\u003e\n\u003cdiv class=\"image-pair\"\u003e\n\u003cimg class=\"desktop-img\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/e448011edd64412b090515ded8262a19.jpg?v=1780117738\" alt=\"USS-HDBV00031 product image\"\u003e\u003cimg class=\"mobile-img\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/e448011edd64412b090515ded8262a19.jpg?v=1780117738\" alt=\"USS-HDBV00031 product image\"\u003e\n\u003c\/div\u003e\n\u003ch2\u003eINTRODUCTION\u003c\/h2\u003e\n\u003cp\u003eThis premium flow control solution integrates a heavy-duty 3-piece stainless steel ball valve with a high-performance electric actuator. Engineered for reliability and precision, it provides a comprehensive hardware suite for automated systems, offering superior durability, seamless integration, and simplified maintenance in demanding industrial environments.\u003c\/p\u003e\n\u003ch2\u003eFEATURES\u003c\/h2\u003e\n\u003cdiv class=\"image-pair\"\u003e\n\u003cimg class=\"desktop-img\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/ig_091236ea01646e01016a1fc6106344819babe6cfa61e9ff177.png?v=1780468642\" alt=\"USS-HDBV00031 features\"\u003e\u003cimg class=\"mobile-img\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/ig_091236ea01646e01016a1fc6106344819babe6cfa61e9ff177.png?v=1780468642\" alt=\"USS-HDBV00031 features\"\u003e\n\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePremium Material Construction:\u003c\/strong\u003e Crafted from high-grade 304 stainless steel, the valve body is highly resistant to corrosion, making it suitable for handling weak acids, weak alkalis, chemical solvents, and water.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaintenance-Friendly 3-Piece Design:\u003c\/strong\u003e The innovative 3-piece body construction allows for seamless in-line maintenance. Internal components can be cleaned or replaced without disconnecting the pipes, helping reduce downtime and service costs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Pressure \u0026amp; Full-Bore Efficiency:\u003c\/strong\u003e The full-bore configuration helps minimize pressure drop and maintain efficient flow capacity in high-pressure systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSmart Automation Ready:\u003c\/strong\u003e Integrated limit switches and position feedback support PLC integration, remote control, real-time monitoring, and automated operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Torque Reliability:\u003c\/strong\u003e A compact, heavy-duty motor delivers steady 50 Nm torque for reliable full-port operation and drop-tight sealing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnhanced Safety \u0026amp; Self-Locking:\u003c\/strong\u003e The actuator features a self-locking mechanism for stable operation and a manual override port for controlled intervention during power outages or emergencies.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRugged Outdoor Durability:\u003c\/strong\u003e A powder-coated polyester aluminum housing provides resistance to corrosion and harsh weather conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdvanced Circuitry Protection:\u003c\/strong\u003e The internal PCBA is treated with a protective sealant to help prevent damage from moisture, condensation, and short circuits.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eAPPLICATIONS\u003c\/h2\u003e\n\u003cdiv class=\"image-pair\"\u003e\n\u003cimg class=\"desktop-img\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/Application_d83d7c67-93f0-46dd-bb8d-c1c7a38e6775.png?v=1779780603\" alt=\"USS-HDBV00031 applications\"\u003e\u003cimg class=\"mobile-img\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/Application_d83d7c67-93f0-46dd-bb8d-c1c7a38e6775.png?v=1779780603\" alt=\"USS-HDBV00031 applications\"\u003e\n\u003c\/div\u003e\n\u003ch2\u003eWIRING DIAGRAMS\u003c\/h2\u003e\n\u003cdiv class=\"wiring-grid\"\u003e\n\u003cdiv class=\"wiring-card\"\u003e\n\u003cdiv class=\"image-pair\"\u003e\n\u003cimg class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/ef.jpg\" alt=\"Wiring diagram A\"\u003e\u003cimg class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/ef.jpg\" alt=\"Wiring diagram A\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"wiring-card\"\u003e\n\u003cdiv class=\"image-pair\"\u003e\n\u003cimg class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/IJ.jpg\" alt=\"Wiring diagram B\"\u003e\u003cimg class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/IJ.jpg\" alt=\"Wiring diagram B\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"control-callout\"\u003e\n\u003ch3\u003eTYPE E: Modulating Type with Integrated Servo Controller\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMulti-Signal Modulating Control:\u003c\/strong\u003e Accepts 4-20 mA, 1-5V, or 0-10V DC input signals to automatically position the valve at the required flow setting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated Electronic Servo Controller:\u003c\/strong\u003e The built-in servo controller continuously adjusts valve position in response to the incoming control signal.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e4-20 mA Position Feedback:\u003c\/strong\u003e Provides a 4-20 mA output signal for compatible PLC, DCS, or process control systems to monitor actual valve position.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClosed-Loop Position Sensing:\u003c\/strong\u003e An integrated 1 kΩ potentiometer provides position feedback for accurate, stable modulation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC Power Input:\u003c\/strong\u003e Uses B1 (L) and B2 (N) terminals for the AC power supply connection, as shown in the wiring diagram.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch2\u003eSPECIFICATIONS\u003c\/h2\u003e\n\u003cdiv class=\"spec-scroll\" role=\"region\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr style=\"border-bottom: 1px dashed #000000;\"\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003eUSS-HDBV00031\u003c\/td\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003eU.S. Solid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed #000000;\"\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eSize\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003e1\/2\"\u003c\/td\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eWiring Type\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003eType E: Modulating Type with Integrated Servo Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed #000000;\"\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eValve Material\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003e304SS\u003c\/td\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eBall Seal\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003ePTFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed #000000;\"\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eOperating Time\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003e20 Seconds\u003c\/td\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eWorking Voltage\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003e110V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed #000000;\"\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eMax Power\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003e20 W\u003c\/td\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eMax Torque\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003e50 N m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed #000000;\"\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eMax Medium Pressure\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003e1.6 Mpa\u003c\/td\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003e-30°C to 180°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed #000000;\"\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eLife Expectancy\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003e30,000 to 50,000 Cycles\u003c\/td\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eBore Type\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003eFull port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed #000000;\"\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eThread Type\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003eNPT\u003c\/td\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eOperating State\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003eRemain in position\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed #000000;\"\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003e-30°C to 60°C\u003c\/td\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eEnclosure Rating\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch2\u003eWARNINGS\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Failure Behavior:\u003c\/strong\u003e This valve remains in its current position during a power outage. It does not automatically return to a preset position.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Match Required:\u003c\/strong\u003e Supply voltage must match the actuator rating exactly. Incorrect voltage may permanently damage the unit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDedicated Power Circuit:\u003c\/strong\u003e Each actuator requires its own fuse-protected power supply. Do not connect multiple actuators in parallel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDisconnect Power Before Service:\u003c\/strong\u003e Always disconnect power before wiring, maintenance, or using the manual override.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP65 Weather Resistant:\u003c\/strong\u003e Suitable for outdoor use, but additional protection is recommended for permanent outdoor installations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow Power Consumption:\u003c\/strong\u003e Power is only used during opening and closing. No power is consumed when fully open or fully closed.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProfessional Installation Recommended:\u003c\/strong\u003e Installation should be performed by qualified personnel familiar with electrical control systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003cp class=\"faq-q\"\u003e1. Can I manually operate the valve?\u003c\/p\u003e\n\u003cp class=\"faq-a\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes. The actuator features a manual override. We recommend manually cycling the valve before installation to verify smooth operation and using the adjustment screws during commissioning to fine-tune the open and closed positions.\u003c\/p\u003e\n\u003cp class=\"faq-q\"\u003e2. Can this valve be installed outdoors?\u003c\/p\u003e\n\u003cp class=\"faq-a\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes, depending on the model's IP rating. While our heavy-duty actuators are weather-resistant, we recommend using a protective cover or shelter for permanent outdoor installations to protect the unit from direct UV exposure and ice buildup.\u003c\/p\u003e\n\u003cp class=\"faq-q\"\u003e3. Is this valve suitable for high-viscosity fluids or particulates?\u003c\/p\u003e\n\u003cp class=\"faq-a\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes, subject to torque considerations. Extremely viscous media or large particulates increase resistance, so ensure the operating torque remains within the actuator's rated capacity to prevent stalling.\u003c\/p\u003e\n\u003cp class=\"faq-q\"\u003e4. Is it normal for the actuator to feel hot during operation?\u003c\/p\u003e\n\u003cp class=\"faq-a\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes. The actuator may feel warm during continuous cycling. If the housing becomes too hot to touch, check that the recommended duty cycle and ambient temperature range of -30°C to 60°C are not exceeded.\u003c\/p\u003e\n\u003cp class=\"faq-q\"\u003e5. Can I wire multiple actuators in parallel on the same circuit?\u003c\/p\u003e\n\u003cp class=\"faq-a\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e No. Each motorized actuator should use its own dedicated, fuse-protected power supply to ensure proper signal response and reduce the risk of electrical interference or damage.\u003c\/p\u003e\n\u003cp style=\"margin-top: 25px;\"\u003eDownload user manual \u003ca href=\"http:\/\/file.ussolid.com\/content\/JFHDBV\/JFHDBV-%20Electric%20Actuated%20Ball%20Valve%20instruction%20manual.pdf\" rel=\"noopener\" target=\"_blank\"\u003ehere\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cstyle\u003e.bv-detail{font-family:Arial,sans-serif;color:#000;line-height:1.62}.bv-detail .desktop-img{display:block}.bv-detail .mobile-img{display:none}.bv-detail img{width:100%;max-width:100%;height:auto;display:block}.bv-detail h2{font-size:22px;font-weight:700;margin:25px 0 10px}.bv-detail p,.bv-detail li{font-size:16px}.bv-detail .image-pair{margin:0 0 20px}.bv-detail .wiring-grid{display:flex;flex-wrap:wrap;gap:15px;margin-bottom:20px}.bv-detail .wiring-card{flex:1;min-width:280px}.bv-detail .wiring-card h3{text-align:center;font-size:16px;margin:0 0 10px}.bv-detail .control-callout{margin:0 0 24px;padding:18px 20px 8px;border-left:4px solid #78b72a;background:#f4f8ee}.bv-detail .control-callout h3{margin:0 0 12px;font-size:17px;color:#16220c}.bv-detail .control-callout ul{margin:0;padding-left:20px}.bv-detail .control-callout li{margin-bottom:9px}.bv-detail .spec-scroll{width:100%;overflow-x:auto;overflow-y:hidden;margin:0 0 20px;-webkit-overflow-scrolling:touch}.bv-detail .spec-scroll table{width:100%;border-collapse:collapse;background:#fff;margin:0}.bv-detail tr{border-bottom:1px dashed #000}.bv-detail th,.bv-detail td{padding:10px;text-align:left;font-size:15px;vertical-align:top}.bv-detail th{width:20%;background:#f0f0f0;font-weight:bold}.bv-detail .faq-q{font-weight:bold;margin:16px 0 5px}.bv-detail .faq-a{margin:0 0 16px;padding-left:15px}.bv-detail a{color:#0066cc;text-decoration:underline}@media(max-width:600px){.bv-detail .desktop-img{display:none!important}.bv-detail .mobile-img{display:block!important}.bv-detail h2{font-size:20px;font-weight:700}.bv-detail p,.bv-detail li{font-size:15px}.bv-detail .wiring-grid{display:block}.bv-detail .wiring-card{margin-bottom:15px}.bv-detail .control-callout{padding:15px 14px 6px}.bv-detail .control-callout h3{font-size:16px}.bv-detail .spec-scroll table{min-width:680px}.bv-detail th,.bv-detail td{padding:8px 9px;font-size:14px;white-space:normal}}\u003c\/style\u003e\n\u003cdiv class=\"bv-detail\"\u003e\n\u003cdiv class=\"image-pair\"\u003e\n\u003cimg class=\"desktop-img\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/e448011edd64412b090515ded8262a19.jpg?v=1780117738\" alt=\"USS-HDBV00031 product image\"\u003e\u003cimg class=\"mobile-img\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/e448011edd64412b090515ded8262a19.jpg?v=1780117738\" alt=\"USS-HDBV00031 product image\"\u003e\n\u003c\/div\u003e\n\u003ch2\u003eINTRODUCTION\u003c\/h2\u003e\n\u003cp\u003eThis premium flow control solution integrates a heavy-duty 3-piece stainless steel ball valve with a high-performance electric actuator. Engineered for reliability and precision, it provides a comprehensive hardware suite for automated systems, offering superior durability, seamless integration, and simplified maintenance in demanding industrial environments.\u003c\/p\u003e\n\u003ch2\u003eFEATURES\u003c\/h2\u003e\n\u003cdiv class=\"image-pair\"\u003e\n\u003cimg class=\"desktop-img\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/ig_091236ea01646e01016a1fc6106344819babe6cfa61e9ff177.png?v=1780468642\" alt=\"USS-HDBV00031 features\"\u003e\u003cimg class=\"mobile-img\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/ig_091236ea01646e01016a1fc6106344819babe6cfa61e9ff177.png?v=1780468642\" alt=\"USS-HDBV00031 features\"\u003e\n\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePremium Material Construction:\u003c\/strong\u003e Crafted from high-grade 304 stainless steel, the valve body is highly resistant to corrosion, making it suitable for handling weak acids, weak alkalis, chemical solvents, and water.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaintenance-Friendly 3-Piece Design:\u003c\/strong\u003e The innovative 3-piece body construction allows for seamless in-line maintenance. Internal components can be cleaned or replaced without disconnecting the pipes, helping reduce downtime and service costs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Pressure \u0026amp; Full-Bore Efficiency:\u003c\/strong\u003e The full-bore configuration helps minimize pressure drop and maintain efficient flow capacity in high-pressure systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSmart Automation Ready:\u003c\/strong\u003e Integrated limit switches and position feedback support PLC integration, remote control, real-time monitoring, and automated operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Torque Reliability:\u003c\/strong\u003e A compact, heavy-duty motor delivers steady 50 Nm torque for reliable full-port operation and drop-tight sealing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnhanced Safety \u0026amp; Self-Locking:\u003c\/strong\u003e The actuator features a self-locking mechanism for stable operation and a manual override port for controlled intervention during power outages or emergencies.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRugged Outdoor Durability:\u003c\/strong\u003e A powder-coated polyester aluminum housing provides resistance to corrosion and harsh weather conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdvanced Circuitry Protection:\u003c\/strong\u003e The internal PCBA is treated with a protective sealant to help prevent damage from moisture, condensation, and short circuits.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eAPPLICATIONS\u003c\/h2\u003e\n\u003cdiv class=\"image-pair\"\u003e\n\u003cimg class=\"desktop-img\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/Application_d83d7c67-93f0-46dd-bb8d-c1c7a38e6775.png?v=1779780603\" alt=\"USS-HDBV00031 applications\"\u003e\u003cimg class=\"mobile-img\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/Application_d83d7c67-93f0-46dd-bb8d-c1c7a38e6775.png?v=1779780603\" alt=\"USS-HDBV00031 applications\"\u003e\n\u003c\/div\u003e\n\u003ch2\u003eWIRING DIAGRAMS\u003c\/h2\u003e\n\u003cdiv class=\"wiring-grid\"\u003e\n\u003cdiv class=\"wiring-card\"\u003e\n\u003cdiv class=\"image-pair\"\u003e\n\u003cimg class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/ef.jpg\" alt=\"Wiring diagram A\"\u003e\u003cimg class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/ef.jpg\" alt=\"Wiring diagram A\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"wiring-card\"\u003e\n\u003cdiv class=\"image-pair\"\u003e\n\u003cimg class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/IJ.jpg\" alt=\"Wiring diagram B\"\u003e\u003cimg class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/IJ.jpg\" alt=\"Wiring diagram B\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"control-callout\"\u003e\n\u003ch3\u003eTYPE E: Modulating Type with Integrated Servo Controller\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMulti-Signal Modulating Control:\u003c\/strong\u003e Accepts 4-20 mA, 1-5V, or 0-10V DC input signals to automatically position the valve at the required flow setting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated Electronic Servo Controller:\u003c\/strong\u003e The built-in servo controller continuously adjusts valve position in response to the incoming control signal.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e4-20 mA Position Feedback:\u003c\/strong\u003e Provides a 4-20 mA output signal for compatible PLC, DCS, or process control systems to monitor actual valve position.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClosed-Loop Position Sensing:\u003c\/strong\u003e An integrated 1 kΩ potentiometer provides position feedback for accurate, stable modulation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC Power Input:\u003c\/strong\u003e Uses B1 (L) and B2 (N) terminals for the AC power supply connection, as shown in the wiring diagram.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch2\u003eSPECIFICATIONS\u003c\/h2\u003e\n\u003cdiv class=\"spec-scroll\" role=\"region\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr style=\"border-bottom: 1px dashed #000000;\"\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003eUSS-HDBV00031\u003c\/td\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003eU.S. Solid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed #000000;\"\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eSize\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003e1\/2\"\u003c\/td\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eWiring Type\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003eType E: Modulating Type with Integrated Servo Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed #000000;\"\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eValve Material\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003e304SS\u003c\/td\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eBall Seal\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003ePTFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed #000000;\"\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eOperating Time\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003e20 Seconds\u003c\/td\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eWorking Voltage\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003e110V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed #000000;\"\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eMax Power\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003e20 W\u003c\/td\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eMax Torque\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003e50 N m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed #000000;\"\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eMax Medium Pressure\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003e1.6 Mpa\u003c\/td\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003e-30°C to 180°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed #000000;\"\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eLife Expectancy\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003e30,000 to 50,000 Cycles\u003c\/td\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eBore Type\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003eFull port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed #000000;\"\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eThread Type\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003eNPT\u003c\/td\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eOperating State\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003eRemain in position\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed #000000;\"\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003e-30°C to 60°C\u003c\/td\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eEnclosure Rating\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch2\u003eWARNINGS\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Failure Behavior:\u003c\/strong\u003e This valve remains in its current position during a power outage. It does not automatically return to a preset position.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Match Required:\u003c\/strong\u003e Supply voltage must match the actuator rating exactly. Incorrect voltage may permanently damage the unit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDedicated Power Circuit:\u003c\/strong\u003e Each actuator requires its own fuse-protected power supply. Do not connect multiple actuators in parallel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDisconnect Power Before Service:\u003c\/strong\u003e Always disconnect power before wiring, maintenance, or using the manual override.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP65 Weather Resistant:\u003c\/strong\u003e Suitable for outdoor use, but additional protection is recommended for permanent outdoor installations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow Power Consumption:\u003c\/strong\u003e Power is only used during opening and closing. No power is consumed when fully open or fully closed.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProfessional Installation Recommended:\u003c\/strong\u003e Installation should be performed by qualified personnel familiar with electrical control systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003cp class=\"faq-q\"\u003e1. Can I manually operate the valve?\u003c\/p\u003e\n\u003cp class=\"faq-a\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes. The actuator features a manual override. We recommend manually cycling the valve before installation to verify smooth operation and using the adjustment screws during commissioning to fine-tune the open and closed positions.\u003c\/p\u003e\n\u003cp class=\"faq-q\"\u003e2. Can this valve be installed outdoors?\u003c\/p\u003e\n\u003cp class=\"faq-a\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes, depending on the model's IP rating. While our heavy-duty actuators are weather-resistant, we recommend using a protective cover or shelter for permanent outdoor installations to protect the unit from direct UV exposure and ice buildup.\u003c\/p\u003e\n\u003cp class=\"faq-q\"\u003e3. Is this valve suitable for high-viscosity fluids or particulates?\u003c\/p\u003e\n\u003cp class=\"faq-a\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes, subject to torque considerations. Extremely viscous media or large particulates increase resistance, so ensure the operating torque remains within the actuator's rated capacity to prevent stalling.\u003c\/p\u003e\n\u003cp class=\"faq-q\"\u003e4. Is it normal for the actuator to feel hot during operation?\u003c\/p\u003e\n\u003cp class=\"faq-a\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes. The actuator may feel warm during continuous cycling. If the housing becomes too hot to touch, check that the recommended duty cycle and ambient temperature range of -30°C to 60°C are not exceeded.\u003c\/p\u003e\n\u003cp class=\"faq-q\"\u003e5. Can I wire multiple actuators in parallel on the same circuit?\u003c\/p\u003e\n\u003cp class=\"faq-a\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e No. Each motorized actuator should use its own dedicated, fuse-protected power supply to ensure proper signal response and reduce the risk of electrical interference or damage.\u003c\/p\u003e\n\u003cp style=\"margin-top: 25px;\"\u003eDownload user manual \u003ca href=\"http:\/\/file.ussolid.com\/content\/JFHDBV\/JFHDBV-%20Electric%20Actuated%20Ball%20Valve%20instruction%20manual.pdf\" rel=\"noopener\" target=\"_blank\"\u003ehere\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"U.S. Solid","offers":[{"title":"Default Title","offer_id":50550693921023,"sku":"JFHDBV00031","price":379.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/2_2f54ce57-deba-4dd9-b2fd-4323d61cd792.jpg?v=1777446926"},{"product_id":"3-4-modulating-electric-ball-valve-110v-ac-heavy-duty-3-piece-304-ss-industrial-ball-valve-4-20ma-proportional-control-with-position-feedback","title":"3\/4\" Modulating Electric Ball Valve, 110V AC Heavy Duty 3-Piece 304 SS Industrial Ball Valve, 4-20mA Proportional Control with Position Feedback","description":"\u003cstyle\u003e.bv-detail{font-family:Arial,sans-serif;color:#000;line-height:1.62}.bv-detail .desktop-img{display:block}.bv-detail .mobile-img{display:none}.bv-detail img{width:100%;max-width:100%;height:auto;display:block}.bv-detail h2{font-size:22px;font-weight:700;margin:25px 0 10px}.bv-detail p,.bv-detail li{font-size:16px}.bv-detail .image-pair{margin:0 0 20px}.bv-detail .wiring-grid{display:flex;flex-wrap:wrap;gap:15px;margin-bottom:20px}.bv-detail .wiring-card{flex:1;min-width:280px}.bv-detail .wiring-card h3{text-align:center;font-size:16px;margin:0 0 10px}.bv-detail .control-callout{margin:0 0 24px;padding:18px 20px 8px;border-left:4px solid #78b72a;background:#f4f8ee}.bv-detail .control-callout h3{margin:0 0 12px;font-size:17px;color:#16220c}.bv-detail .control-callout ul{margin:0;padding-left:20px}.bv-detail .control-callout li{margin-bottom:9px}.bv-detail .spec-scroll{width:100%;overflow-x:auto;overflow-y:hidden;margin:0 0 20px;-webkit-overflow-scrolling:touch}.bv-detail .spec-scroll table{width:100%;border-collapse:collapse;background:#fff;margin:0}.bv-detail tr{border-bottom:1px dashed #000}.bv-detail th,.bv-detail td{padding:10px;text-align:left;font-size:15px;vertical-align:top}.bv-detail th{width:20%;background:#f0f0f0;font-weight:bold}.bv-detail .faq-q{font-weight:bold;margin:16px 0 5px}.bv-detail .faq-a{margin:0 0 16px;padding-left:15px}.bv-detail a{color:#0066cc;text-decoration:underline}@media(max-width:600px){.bv-detail .desktop-img{display:none!important}.bv-detail .mobile-img{display:block!important}.bv-detail h2{font-size:20px;font-weight:700}.bv-detail p,.bv-detail li{font-size:15px}.bv-detail .wiring-grid{display:block}.bv-detail .wiring-card{margin-bottom:15px}.bv-detail .control-callout{padding:15px 14px 6px}.bv-detail .control-callout h3{font-size:16px}.bv-detail .spec-scroll table{min-width:680px}.bv-detail th,.bv-detail td{padding:8px 9px;font-size:14px;white-space:normal}}\u003c\/style\u003e\n\u003cdiv class=\"bv-detail\"\u003e\n\u003cdiv class=\"image-pair\"\u003e\n\u003cimg class=\"desktop-img\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/e448011edd64412b090515ded8262a19.jpg?v=1780117738\" alt=\"USS-HDBV00032 product image\"\u003e\u003cimg class=\"mobile-img\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/e448011edd64412b090515ded8262a19.jpg?v=1780117738\" alt=\"USS-HDBV00032 product image\"\u003e\n\u003c\/div\u003e\n\u003ch2\u003eINTRODUCTION\u003c\/h2\u003e\n\u003cp\u003eThis premium flow control solution integrates a heavy-duty 3-piece stainless steel ball valve with a high-performance electric actuator. Engineered for reliability and precision, it provides a comprehensive hardware suite for automated systems, offering superior durability, seamless integration, and simplified maintenance in demanding industrial environments.\u003c\/p\u003e\n\u003ch2\u003eFEATURES\u003c\/h2\u003e\n\u003cdiv class=\"image-pair\"\u003e\n\u003cimg class=\"desktop-img\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/ig_091236ea01646e01016a1fc6106344819babe6cfa61e9ff177.png?v=1780468642\" alt=\"USS-HDBV00032 features\"\u003e\u003cimg class=\"mobile-img\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/ig_091236ea01646e01016a1fc6106344819babe6cfa61e9ff177.png?v=1780468642\" alt=\"USS-HDBV00032 features\"\u003e\n\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePremium Material Construction:\u003c\/strong\u003e Crafted from high-grade 304 stainless steel, the valve body is highly resistant to corrosion, making it suitable for handling weak acids, weak alkalis, chemical solvents, and water.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaintenance-Friendly 3-Piece Design:\u003c\/strong\u003e The innovative 3-piece body construction allows for seamless in-line maintenance. Internal components can be cleaned or replaced without disconnecting the pipes, helping reduce downtime and service costs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Pressure \u0026amp; Full-Bore Efficiency:\u003c\/strong\u003e The full-bore configuration helps minimize pressure drop and maintain efficient flow capacity in high-pressure systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSmart Automation Ready:\u003c\/strong\u003e Integrated limit switches and position feedback support PLC integration, remote control, real-time monitoring, and automated operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Torque Reliability:\u003c\/strong\u003e A compact, heavy-duty motor delivers steady 50 Nm torque for reliable full-port operation and drop-tight sealing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnhanced Safety \u0026amp; Self-Locking:\u003c\/strong\u003e The actuator features a self-locking mechanism for stable operation and a manual override port for controlled intervention during power outages or emergencies.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRugged Outdoor Durability:\u003c\/strong\u003e A powder-coated polyester aluminum housing provides resistance to corrosion and harsh weather conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdvanced Circuitry Protection:\u003c\/strong\u003e The internal PCBA is treated with a protective sealant to help prevent damage from moisture, condensation, and short circuits.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eAPPLICATIONS\u003c\/h2\u003e\n\u003cdiv class=\"image-pair\"\u003e\n\u003cimg class=\"desktop-img\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/Application_d83d7c67-93f0-46dd-bb8d-c1c7a38e6775.png?v=1779780603\" alt=\"USS-HDBV00032 applications\"\u003e\u003cimg class=\"mobile-img\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/Application_d83d7c67-93f0-46dd-bb8d-c1c7a38e6775.png?v=1779780603\" alt=\"USS-HDBV00032 applications\"\u003e\n\u003c\/div\u003e\n\u003ch2\u003eWIRING DIAGRAMS\u003c\/h2\u003e\n\u003cdiv class=\"wiring-grid\"\u003e\n\u003cdiv class=\"wiring-card\"\u003e\n\u003cdiv class=\"image-pair\"\u003e\n\u003cimg class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/ef.jpg\" alt=\"Wiring diagram A\"\u003e\u003cimg class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/ef.jpg\" alt=\"Wiring diagram A\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"wiring-card\"\u003e\n\u003cdiv class=\"image-pair\"\u003e\n\u003cimg class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/IJ.jpg\" alt=\"Wiring diagram B\"\u003e\u003cimg class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/IJ.jpg\" alt=\"Wiring diagram B\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"control-callout\"\u003e\n\u003ch3\u003eTYPE E: Modulating Type with Integrated Servo Controller\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMulti-Signal Modulating Control:\u003c\/strong\u003e Accepts 4-20 mA, 1-5V, or 0-10V DC input signals to automatically position the valve at the required flow setting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated Electronic Servo Controller:\u003c\/strong\u003e The built-in servo controller continuously adjusts valve position in response to the incoming control signal.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e4-20 mA Position Feedback:\u003c\/strong\u003e Provides a 4-20 mA output signal for compatible PLC, DCS, or process control systems to monitor actual valve position.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClosed-Loop Position Sensing:\u003c\/strong\u003e An integrated 1 kΩ potentiometer provides position feedback for accurate, stable modulation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC Power Input:\u003c\/strong\u003e Uses B1 (L) and B2 (N) terminals for the AC power supply connection, as shown in the wiring diagram.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch2\u003eSPECIFICATIONS\u003c\/h2\u003e\n\u003cdiv class=\"spec-scroll\" role=\"region\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr style=\"border-bottom: 1px dashed #000000;\"\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003eUSS-HDBV00032\u003c\/td\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003eU.S. Solid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed #000000;\"\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eSize\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003e3\/4\"\u003c\/td\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eWiring Type\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003eType E: Modulating Type with Integrated Servo Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed #000000;\"\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eValve Material\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003e304SS\u003c\/td\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eBall Seal\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003ePTFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed #000000;\"\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eOperating Time\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003e20 Seconds\u003c\/td\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eWorking Voltage\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003e110V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed #000000;\"\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eMax Power\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003e20 W\u003c\/td\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eMax Torque\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003e50 N m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed #000000;\"\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eMax Medium Pressure\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003e1.6 Mpa\u003c\/td\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003e-30°C to 180°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed #000000;\"\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eLife Expectancy\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003e30,000 to 50,000 Cycles\u003c\/td\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eBore Type\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003eFull port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed #000000;\"\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eThread Type\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003eNPT\u003c\/td\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eOperating State\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003eRemain in position\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed #000000;\"\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003e-30°C to 60°C\u003c\/td\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eEnclosure Rating\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch2\u003eWARNINGS\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Failure Behavior:\u003c\/strong\u003e This valve remains in its current position during a power outage. It does not automatically return to a preset position.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Match Required:\u003c\/strong\u003e Supply voltage must match the actuator rating exactly. Incorrect voltage may permanently damage the unit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDedicated Power Circuit:\u003c\/strong\u003e Each actuator requires its own fuse-protected power supply. Do not connect multiple actuators in parallel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDisconnect Power Before Service:\u003c\/strong\u003e Always disconnect power before wiring, maintenance, or using the manual override.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP65 Weather Resistant:\u003c\/strong\u003e Suitable for outdoor use, but additional protection is recommended for permanent outdoor installations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow Power Consumption:\u003c\/strong\u003e Power is only used during opening and closing. No power is consumed when fully open or fully closed.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProfessional Installation Recommended:\u003c\/strong\u003e Installation should be performed by qualified personnel familiar with electrical control systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003cp class=\"faq-q\"\u003e1. Can I manually operate the valve?\u003c\/p\u003e\n\u003cp class=\"faq-a\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes. The actuator features a manual override. We recommend manually cycling the valve before installation to verify smooth operation and using the adjustment screws during commissioning to fine-tune the open and closed positions.\u003c\/p\u003e\n\u003cp class=\"faq-q\"\u003e2. Can this valve be installed outdoors?\u003c\/p\u003e\n\u003cp class=\"faq-a\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes, depending on the model's IP rating. While our heavy-duty actuators are weather-resistant, we recommend using a protective cover or shelter for permanent outdoor installations to protect the unit from direct UV exposure and ice buildup.\u003c\/p\u003e\n\u003cp class=\"faq-q\"\u003e3. Is this valve suitable for high-viscosity fluids or particulates?\u003c\/p\u003e\n\u003cp class=\"faq-a\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes, subject to torque considerations. Extremely viscous media or large particulates increase resistance, so ensure the operating torque remains within the actuator's rated capacity to prevent stalling.\u003c\/p\u003e\n\u003cp class=\"faq-q\"\u003e4. Is it normal for the actuator to feel hot during operation?\u003c\/p\u003e\n\u003cp class=\"faq-a\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes. The actuator may feel warm during continuous cycling. If the housing becomes too hot to touch, check that the recommended duty cycle and ambient temperature range of -30°C to 60°C are not exceeded.\u003c\/p\u003e\n\u003cp class=\"faq-q\"\u003e5. Can I wire multiple actuators in parallel on the same circuit?\u003c\/p\u003e\n\u003cp class=\"faq-a\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e No. Each motorized actuator should use its own dedicated, fuse-protected power supply to ensure proper signal response and reduce the risk of electrical interference or damage.\u003c\/p\u003e\n\u003cp style=\"margin-top: 25px;\"\u003eDownload user manual \u003ca href=\"http:\/\/file.ussolid.com\/content\/JFHDBV\/JFHDBV-%20Electric%20Actuated%20Ball%20Valve%20instruction%20manual.pdf\" rel=\"noopener\" target=\"_blank\"\u003ehere\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"U.S. Solid","offers":[{"title":"Default Title","offer_id":50550693953791,"sku":"JFHDBV00032","price":389.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/2_4547e780-18d0-49c9-839d-f5f237217c48.jpg?v=1778311525"},{"product_id":"1-modulating-electric-ball-valve-110v-ac-heavy-duty-3-piece-304-ss-industrial-ball-valve-4-20ma-proportional-control-with-position-feedback","title":"1\" Modulating Electric Ball Valve, 110V AC Heavy Duty 3-Piece 304 SS Industrial Ball Valve, 4-20mA Proportional Control with Position Feedback","description":"\u003cstyle\u003e.bv-detail{font-family:Arial,sans-serif;color:#000;line-height:1.62}.bv-detail .desktop-img{display:block}.bv-detail .mobile-img{display:none}.bv-detail img{width:100%;max-width:100%;height:auto;display:block}.bv-detail h2{font-size:22px;font-weight:700;margin:25px 0 10px}.bv-detail p,.bv-detail li{font-size:16px}.bv-detail .image-pair{margin:0 0 20px}.bv-detail .wiring-grid{display:flex;flex-wrap:wrap;gap:15px;margin-bottom:20px}.bv-detail .wiring-card{flex:1;min-width:280px}.bv-detail .wiring-card h3{text-align:center;font-size:16px;margin:0 0 10px}.bv-detail .control-callout{margin:0 0 24px;padding:18px 20px 8px;border-left:4px solid #78b72a;background:#f4f8ee}.bv-detail .control-callout h3{margin:0 0 12px;font-size:17px;color:#16220c}.bv-detail .control-callout ul{margin:0;padding-left:20px}.bv-detail .control-callout li{margin-bottom:9px}.bv-detail .spec-scroll{width:100%;overflow-x:auto;overflow-y:hidden;margin:0 0 20px;-webkit-overflow-scrolling:touch}.bv-detail .spec-scroll table{width:100%;border-collapse:collapse;background:#fff;margin:0}.bv-detail tr{border-bottom:1px dashed #000}.bv-detail th,.bv-detail td{padding:10px;text-align:left;font-size:15px;vertical-align:top}.bv-detail th{width:20%;background:#f0f0f0;font-weight:bold}.bv-detail .faq-q{font-weight:bold;margin:16px 0 5px}.bv-detail .faq-a{margin:0 0 16px;padding-left:15px}.bv-detail a{color:#0066cc;text-decoration:underline}@media(max-width:600px){.bv-detail .desktop-img{display:none!important}.bv-detail .mobile-img{display:block!important}.bv-detail h2{font-size:20px;font-weight:700}.bv-detail p,.bv-detail li{font-size:15px}.bv-detail .wiring-grid{display:block}.bv-detail .wiring-card{margin-bottom:15px}.bv-detail .control-callout{padding:15px 14px 6px}.bv-detail .control-callout h3{font-size:16px}.bv-detail .spec-scroll table{min-width:680px}.bv-detail th,.bv-detail td{padding:8px 9px;font-size:14px;white-space:normal}}\u003c\/style\u003e\n\u003cdiv class=\"bv-detail\"\u003e\n\u003cdiv class=\"image-pair\"\u003e\n\u003cimg class=\"desktop-img\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/e448011edd64412b090515ded8262a19.jpg?v=1780117738\" alt=\"USS-HDBV00033 product image\"\u003e\u003cimg class=\"mobile-img\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/e448011edd64412b090515ded8262a19.jpg?v=1780117738\" alt=\"USS-HDBV00033 product image\"\u003e\n\u003c\/div\u003e\n\u003ch2\u003eINTRODUCTION\u003c\/h2\u003e\n\u003cp\u003eThis premium flow control solution integrates a heavy-duty 3-piece stainless steel ball valve with a high-performance electric actuator. Engineered for reliability and precision, it provides a comprehensive hardware suite for automated systems, offering superior durability, seamless integration, and simplified maintenance in demanding industrial environments.\u003c\/p\u003e\n\u003ch2\u003eFEATURES\u003c\/h2\u003e\n\u003cdiv class=\"image-pair\"\u003e\n\u003cimg class=\"desktop-img\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/ig_091236ea01646e01016a1fc6106344819babe6cfa61e9ff177.png?v=1780468642\" alt=\"USS-HDBV00033 features\"\u003e\u003cimg class=\"mobile-img\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/ig_091236ea01646e01016a1fc6106344819babe6cfa61e9ff177.png?v=1780468642\" alt=\"USS-HDBV00033 features\"\u003e\n\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePremium Material Construction:\u003c\/strong\u003e Crafted from high-grade 304 stainless steel, the valve body is highly resistant to corrosion, making it suitable for handling weak acids, weak alkalis, chemical solvents, and water.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaintenance-Friendly 3-Piece Design:\u003c\/strong\u003e The innovative 3-piece body construction allows for seamless in-line maintenance. Internal components can be cleaned or replaced without disconnecting the pipes, helping reduce downtime and service costs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Pressure \u0026amp; Full-Bore Efficiency:\u003c\/strong\u003e The full-bore configuration helps minimize pressure drop and maintain efficient flow capacity in high-pressure systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSmart Automation Ready:\u003c\/strong\u003e Integrated limit switches and position feedback support PLC integration, remote control, real-time monitoring, and automated operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Torque Reliability:\u003c\/strong\u003e A compact, heavy-duty motor delivers steady 50 Nm torque for reliable full-port operation and drop-tight sealing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnhanced Safety \u0026amp; Self-Locking:\u003c\/strong\u003e The actuator features a self-locking mechanism for stable operation and a manual override port for controlled intervention during power outages or emergencies.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRugged Outdoor Durability:\u003c\/strong\u003e A powder-coated polyester aluminum housing provides resistance to corrosion and harsh weather conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdvanced Circuitry Protection:\u003c\/strong\u003e The internal PCBA is treated with a protective sealant to help prevent damage from moisture, condensation, and short circuits.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eAPPLICATIONS\u003c\/h2\u003e\n\u003cdiv class=\"image-pair\"\u003e\n\u003cimg class=\"desktop-img\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/Application_d83d7c67-93f0-46dd-bb8d-c1c7a38e6775.png?v=1779780603\" alt=\"USS-HDBV00033 applications\"\u003e\u003cimg class=\"mobile-img\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/Application_d83d7c67-93f0-46dd-bb8d-c1c7a38e6775.png?v=1779780603\" alt=\"USS-HDBV00033 applications\"\u003e\n\u003c\/div\u003e\n\u003ch2\u003eWIRING DIAGRAMS\u003c\/h2\u003e\n\u003cdiv class=\"wiring-grid\"\u003e\n\u003cdiv class=\"wiring-card\"\u003e\n\u003cdiv class=\"image-pair\"\u003e\n\u003cimg class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/ef.jpg\" alt=\"Wiring diagram A\"\u003e\u003cimg class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/ef.jpg\" alt=\"Wiring diagram A\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"wiring-card\"\u003e\n\u003cdiv class=\"image-pair\"\u003e\n\u003cimg class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/IJ.jpg\" alt=\"Wiring diagram B\"\u003e\u003cimg class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/IJ.jpg\" alt=\"Wiring diagram B\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"control-callout\"\u003e\n\u003ch3\u003eTYPE E: Modulating Type with Integrated Servo Controller\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMulti-Signal Modulating Control:\u003c\/strong\u003e Accepts 4-20 mA, 1-5V, or 0-10V DC input signals to automatically position the valve at the required flow setting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated Electronic Servo Controller:\u003c\/strong\u003e The built-in servo controller continuously adjusts valve position in response to the incoming control signal.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e4-20 mA Position Feedback:\u003c\/strong\u003e Provides a 4-20 mA output signal for compatible PLC, DCS, or process control systems to monitor actual valve position.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClosed-Loop Position Sensing:\u003c\/strong\u003e An integrated 1 kΩ potentiometer provides position feedback for accurate, stable modulation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC Power Input:\u003c\/strong\u003e Uses B1 (L) and B2 (N) terminals for the AC power supply connection, as shown in the wiring diagram.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch2\u003eSPECIFICATIONS\u003c\/h2\u003e\n\u003cdiv class=\"spec-scroll\" role=\"region\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr style=\"border-bottom: 1px dashed #000000;\"\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003eUSS-HDBV00033\u003c\/td\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003eU.S. Solid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed #000000;\"\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eSize\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003e1\"\u003c\/td\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eWiring Type\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003eType E: Modulating Type with Integrated Servo Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed #000000;\"\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eValve Material\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003e304SS\u003c\/td\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eBall Seal\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003ePTFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed #000000;\"\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eOperating Time\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003e20 Seconds\u003c\/td\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eWorking Voltage\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003e110V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed #000000;\"\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eMax Power\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003e20 W\u003c\/td\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eMax Torque\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003e50 N m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed #000000;\"\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eMax Medium Pressure\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003e1.6 Mpa\u003c\/td\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003e-30°C to 180°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed #000000;\"\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eLife Expectancy\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003e30,000 to 50,000 Cycles\u003c\/td\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eBore Type\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003eFull port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed #000000;\"\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eThread Type\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003eNPT\u003c\/td\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eOperating State\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003eRemain in position\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed #000000;\"\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003e-30°C to 60°C\u003c\/td\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eEnclosure Rating\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch2\u003eWARNINGS\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Failure Behavior:\u003c\/strong\u003e This valve remains in its current position during a power outage. It does not automatically return to a preset position.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Match Required:\u003c\/strong\u003e Supply voltage must match the actuator rating exactly. Incorrect voltage may permanently damage the unit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDedicated Power Circuit:\u003c\/strong\u003e Each actuator requires its own fuse-protected power supply. Do not connect multiple actuators in parallel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDisconnect Power Before Service:\u003c\/strong\u003e Always disconnect power before wiring, maintenance, or using the manual override.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP65 Weather Resistant:\u003c\/strong\u003e Suitable for outdoor use, but additional protection is recommended for permanent outdoor installations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow Power Consumption:\u003c\/strong\u003e Power is only used during opening and closing. No power is consumed when fully open or fully closed.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProfessional Installation Recommended:\u003c\/strong\u003e Installation should be performed by qualified personnel familiar with electrical control systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003cp class=\"faq-q\"\u003e1. Can I manually operate the valve?\u003c\/p\u003e\n\u003cp class=\"faq-a\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes. The actuator features a manual override. We recommend manually cycling the valve before installation to verify smooth operation and using the adjustment screws during commissioning to fine-tune the open and closed positions.\u003c\/p\u003e\n\u003cp class=\"faq-q\"\u003e2. Can this valve be installed outdoors?\u003c\/p\u003e\n\u003cp class=\"faq-a\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes, depending on the model's IP rating. While our heavy-duty actuators are weather-resistant, we recommend using a protective cover or shelter for permanent outdoor installations to protect the unit from direct UV exposure and ice buildup.\u003c\/p\u003e\n\u003cp class=\"faq-q\"\u003e3. Is this valve suitable for high-viscosity fluids or particulates?\u003c\/p\u003e\n\u003cp class=\"faq-a\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes, subject to torque considerations. Extremely viscous media or large particulates increase resistance, so ensure the operating torque remains within the actuator's rated capacity to prevent stalling.\u003c\/p\u003e\n\u003cp class=\"faq-q\"\u003e4. Is it normal for the actuator to feel hot during operation?\u003c\/p\u003e\n\u003cp class=\"faq-a\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes. The actuator may feel warm during continuous cycling. If the housing becomes too hot to touch, check that the recommended duty cycle and ambient temperature range of -30°C to 60°C are not exceeded.\u003c\/p\u003e\n\u003cp class=\"faq-q\"\u003e5. Can I wire multiple actuators in parallel on the same circuit?\u003c\/p\u003e\n\u003cp class=\"faq-a\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e No. Each motorized actuator should use its own dedicated, fuse-protected power supply to ensure proper signal response and reduce the risk of electrical interference or damage.\u003c\/p\u003e\n\u003cp style=\"margin-top: 25px;\"\u003eDownload user manual \u003ca href=\"http:\/\/file.ussolid.com\/content\/JFHDBV\/JFHDBV-%20Electric%20Actuated%20Ball%20Valve%20instruction%20manual.pdf\" rel=\"noopener\" target=\"_blank\"\u003ehere\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"U.S. Solid","offers":[{"title":"Default Title","offer_id":50550694019327,"sku":"JFHDBV00033","price":419.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/2_9e46fbdb-b336-447e-950c-956a8b771403.jpg?v=1778312036"},{"product_id":"1-1-4-modulating-electric-ball-valve-110v-ac-heavy-duty-3-piece-304-ss-industrial-ball-valve-4-20ma-proportional-control-with-position-feedback","title":"1 1\/4\" Modulating Electric Ball Valve, 110V AC Heavy Duty 3-Piece 304 SS Industrial Ball Valve, 4-20mA Proportional Control with Position Feedback","description":"\u003cstyle\u003e.bv-detail{font-family:Arial,sans-serif;color:#000;line-height:1.62}.bv-detail .desktop-img{display:block}.bv-detail .mobile-img{display:none}.bv-detail img{width:100%;max-width:100%;height:auto;display:block}.bv-detail h2{font-size:22px;font-weight:700;margin:25px 0 10px}.bv-detail p,.bv-detail li{font-size:16px}.bv-detail .image-pair{margin:0 0 20px}.bv-detail .wiring-grid{display:flex;flex-wrap:wrap;gap:15px;margin-bottom:20px}.bv-detail .wiring-card{flex:1;min-width:280px}.bv-detail .wiring-card h3{text-align:center;font-size:16px;margin:0 0 10px}.bv-detail .control-callout{margin:0 0 24px;padding:18px 20px 8px;border-left:4px solid #78b72a;background:#f4f8ee}.bv-detail .control-callout h3{margin:0 0 12px;font-size:17px;color:#16220c}.bv-detail .control-callout ul{margin:0;padding-left:20px}.bv-detail .control-callout li{margin-bottom:9px}.bv-detail .spec-scroll{width:100%;overflow-x:auto;overflow-y:hidden;margin:0 0 20px;-webkit-overflow-scrolling:touch}.bv-detail .spec-scroll table{width:100%;border-collapse:collapse;background:#fff;margin:0}.bv-detail tr{border-bottom:1px dashed #000}.bv-detail th,.bv-detail td{padding:10px;text-align:left;font-size:15px;vertical-align:top}.bv-detail th{width:20%;background:#f0f0f0;font-weight:bold}.bv-detail .faq-q{font-weight:bold;margin:16px 0 5px}.bv-detail .faq-a{margin:0 0 16px;padding-left:15px}.bv-detail a{color:#0066cc;text-decoration:underline}@media(max-width:600px){.bv-detail .desktop-img{display:none!important}.bv-detail .mobile-img{display:block!important}.bv-detail h2{font-size:20px;font-weight:700}.bv-detail p,.bv-detail li{font-size:15px}.bv-detail .wiring-grid{display:block}.bv-detail .wiring-card{margin-bottom:15px}.bv-detail .control-callout{padding:15px 14px 6px}.bv-detail .control-callout h3{font-size:16px}.bv-detail .spec-scroll table{min-width:680px}.bv-detail th,.bv-detail td{padding:8px 9px;font-size:14px;white-space:normal}}\u003c\/style\u003e\n\u003cdiv class=\"bv-detail\"\u003e\n\u003cdiv class=\"image-pair\"\u003e\n\u003cimg class=\"desktop-img\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/e448011edd64412b090515ded8262a19.jpg?v=1780117738\" alt=\"USS-HDBV00034 product image\"\u003e\u003cimg class=\"mobile-img\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/e448011edd64412b090515ded8262a19.jpg?v=1780117738\" alt=\"USS-HDBV00034 product image\"\u003e\n\u003c\/div\u003e\n\u003ch2\u003eINTRODUCTION\u003c\/h2\u003e\n\u003cp\u003eThis premium flow control solution integrates a heavy-duty 3-piece stainless steel ball valve with a high-performance electric actuator. Engineered for reliability and precision, it provides a comprehensive hardware suite for automated systems, offering superior durability, seamless integration, and simplified maintenance in demanding industrial environments.\u003c\/p\u003e\n\u003ch2\u003eFEATURES\u003c\/h2\u003e\n\u003cdiv class=\"image-pair\"\u003e\n\u003cimg class=\"desktop-img\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/ig_091236ea01646e01016a1fc6106344819babe6cfa61e9ff177.png?v=1780468642\" alt=\"USS-HDBV00034 features\"\u003e\u003cimg class=\"mobile-img\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/ig_091236ea01646e01016a1fc6106344819babe6cfa61e9ff177.png?v=1780468642\" alt=\"USS-HDBV00034 features\"\u003e\n\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePremium Material Construction:\u003c\/strong\u003e Crafted from high-grade 304 stainless steel, the valve body is highly resistant to corrosion, making it suitable for handling weak acids, weak alkalis, chemical solvents, and water.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaintenance-Friendly 3-Piece Design:\u003c\/strong\u003e The innovative 3-piece body construction allows for seamless in-line maintenance. Internal components can be cleaned or replaced without disconnecting the pipes, helping reduce downtime and service costs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Pressure \u0026amp; Full-Bore Efficiency:\u003c\/strong\u003e The full-bore configuration helps minimize pressure drop and maintain efficient flow capacity in high-pressure systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSmart Automation Ready:\u003c\/strong\u003e Integrated limit switches and position feedback support PLC integration, remote control, real-time monitoring, and automated operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Torque Reliability:\u003c\/strong\u003e A compact, heavy-duty motor delivers steady 50 Nm torque for reliable full-port operation and drop-tight sealing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnhanced Safety \u0026amp; Self-Locking:\u003c\/strong\u003e The actuator features a self-locking mechanism for stable operation and a manual override port for controlled intervention during power outages or emergencies.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRugged Outdoor Durability:\u003c\/strong\u003e A powder-coated polyester aluminum housing provides resistance to corrosion and harsh weather conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdvanced Circuitry Protection:\u003c\/strong\u003e The internal PCBA is treated with a protective sealant to help prevent damage from moisture, condensation, and short circuits.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eAPPLICATIONS\u003c\/h2\u003e\n\u003cdiv class=\"image-pair\"\u003e\n\u003cimg class=\"desktop-img\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/Application_d83d7c67-93f0-46dd-bb8d-c1c7a38e6775.png?v=1779780603\" alt=\"USS-HDBV00034 applications\"\u003e\u003cimg class=\"mobile-img\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/Application_d83d7c67-93f0-46dd-bb8d-c1c7a38e6775.png?v=1779780603\" alt=\"USS-HDBV00034 applications\"\u003e\n\u003c\/div\u003e\n\u003ch2\u003eWIRING DIAGRAMS\u003c\/h2\u003e\n\u003cdiv class=\"wiring-grid\"\u003e\n\u003cdiv class=\"wiring-card\"\u003e\n\u003cdiv class=\"image-pair\"\u003e\n\u003cimg class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/ef.jpg\" alt=\"Wiring diagram A\"\u003e\u003cimg class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/ef.jpg\" alt=\"Wiring diagram A\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"wiring-card\"\u003e\n\u003cdiv class=\"image-pair\"\u003e\n\u003cimg class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/IJ.jpg\" alt=\"Wiring diagram B\"\u003e\u003cimg class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/IJ.jpg\" alt=\"Wiring diagram B\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"control-callout\"\u003e\n\u003ch3\u003eTYPE E: Modulating Type with Integrated Servo Controller\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMulti-Signal Modulating Control:\u003c\/strong\u003e Accepts 4-20 mA, 1-5V, or 0-10V DC input signals to automatically position the valve at the required flow setting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated Electronic Servo Controller:\u003c\/strong\u003e The built-in servo controller continuously adjusts valve position in response to the incoming control signal.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e4-20 mA Position Feedback:\u003c\/strong\u003e Provides a 4-20 mA output signal for compatible PLC, DCS, or process control systems to monitor actual valve position.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClosed-Loop Position Sensing:\u003c\/strong\u003e An integrated 1 kΩ potentiometer provides position feedback for accurate, stable modulation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC Power Input:\u003c\/strong\u003e Uses B1 (L) and B2 (N) terminals for the AC power supply connection, as shown in the wiring diagram.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch2\u003eSPECIFICATIONS\u003c\/h2\u003e\n\u003cdiv class=\"spec-scroll\" role=\"region\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr style=\"border-bottom: 1px dashed #000000;\"\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003eUSS-HDBV00034\u003c\/td\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003eU.S. Solid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed #000000;\"\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eSize\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003e1 1\/4\"\u003c\/td\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eWiring Type\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003eType E: Modulating Type with Integrated Servo Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed #000000;\"\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eValve Material\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003e304SS\u003c\/td\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eBall Seal\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003ePTFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed #000000;\"\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eOperating Time\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003e20 Seconds\u003c\/td\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eWorking Voltage\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003e110V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed #000000;\"\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eMax Power\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003e20 W\u003c\/td\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eMax Torque\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003e50 N m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed #000000;\"\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eMax Medium Pressure\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003e1.6 Mpa\u003c\/td\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003e-30°C to 180°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed #000000;\"\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eLife Expectancy\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003e30,000 to 50,000 Cycles\u003c\/td\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eBore Type\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003eFull port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed #000000;\"\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eThread Type\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003eNPT\u003c\/td\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eOperating State\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003eRemain in position\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed #000000;\"\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003e-30°C to 60°C\u003c\/td\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eEnclosure Rating\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch2\u003eWARNINGS\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Failure Behavior:\u003c\/strong\u003e This valve remains in its current position during a power outage. It does not automatically return to a preset position.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Match Required:\u003c\/strong\u003e Supply voltage must match the actuator rating exactly. Incorrect voltage may permanently damage the unit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDedicated Power Circuit:\u003c\/strong\u003e Each actuator requires its own fuse-protected power supply. Do not connect multiple actuators in parallel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDisconnect Power Before Service:\u003c\/strong\u003e Always disconnect power before wiring, maintenance, or using the manual override.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP65 Weather Resistant:\u003c\/strong\u003e Suitable for outdoor use, but additional protection is recommended for permanent outdoor installations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow Power Consumption:\u003c\/strong\u003e Power is only used during opening and closing. No power is consumed when fully open or fully closed.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProfessional Installation Recommended:\u003c\/strong\u003e Installation should be performed by qualified personnel familiar with electrical control systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003cp class=\"faq-q\"\u003e1. Can I manually operate the valve?\u003c\/p\u003e\n\u003cp class=\"faq-a\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes. The actuator features a manual override. We recommend manually cycling the valve before installation to verify smooth operation and using the adjustment screws during commissioning to fine-tune the open and closed positions.\u003c\/p\u003e\n\u003cp class=\"faq-q\"\u003e2. Can this valve be installed outdoors?\u003c\/p\u003e\n\u003cp class=\"faq-a\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes, depending on the model's IP rating. While our heavy-duty actuators are weather-resistant, we recommend using a protective cover or shelter for permanent outdoor installations to protect the unit from direct UV exposure and ice buildup.\u003c\/p\u003e\n\u003cp class=\"faq-q\"\u003e3. Is this valve suitable for high-viscosity fluids or particulates?\u003c\/p\u003e\n\u003cp class=\"faq-a\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes, subject to torque considerations. Extremely viscous media or large particulates increase resistance, so ensure the operating torque remains within the actuator's rated capacity to prevent stalling.\u003c\/p\u003e\n\u003cp class=\"faq-q\"\u003e4. Is it normal for the actuator to feel hot during operation?\u003c\/p\u003e\n\u003cp class=\"faq-a\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes. The actuator may feel warm during continuous cycling. If the housing becomes too hot to touch, check that the recommended duty cycle and ambient temperature range of -30°C to 60°C are not exceeded.\u003c\/p\u003e\n\u003cp class=\"faq-q\"\u003e5. Can I wire multiple actuators in parallel on the same circuit?\u003c\/p\u003e\n\u003cp class=\"faq-a\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e No. Each motorized actuator should use its own dedicated, fuse-protected power supply to ensure proper signal response and reduce the risk of electrical interference or damage.\u003c\/p\u003e\n\u003cp style=\"margin-top: 25px;\"\u003eDownload user manual \u003ca href=\"http:\/\/file.ussolid.com\/content\/JFHDBV\/JFHDBV-%20Electric%20Actuated%20Ball%20Valve%20instruction%20manual.pdf\" rel=\"noopener\" target=\"_blank\"\u003ehere\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"U.S. Solid","offers":[{"title":"Default Title","offer_id":50550694052095,"sku":"JFHDBV00034","price":429.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/1_82ed4319-d78a-4cd0-98eb-202e06a44788.jpg?v=1778312794"},{"product_id":"1-1-2-modulating-electric-ball-valve-110v-ac-heavy-duty-3-piece-304-ss-industrial-ball-valve-4-20ma-proportional-control-with-position-feedback","title":"1 1\/2\" Modulating Electric Ball Valve, 110V AC Heavy Duty 3-Piece 304 SS Industrial Ball Valve, 4-20mA Proportional Control with Position Feedback","description":"\u003cstyle\u003e.bv-detail{font-family:Arial,sans-serif;color:#000;line-height:1.62}.bv-detail .desktop-img{display:block}.bv-detail .mobile-img{display:none}.bv-detail img{width:100%;max-width:100%;height:auto;display:block}.bv-detail h2{font-size:22px;font-weight:700;margin:25px 0 10px}.bv-detail p,.bv-detail li{font-size:16px}.bv-detail .image-pair{margin:0 0 20px}.bv-detail .wiring-grid{display:flex;flex-wrap:wrap;gap:15px;margin-bottom:20px}.bv-detail .wiring-card{flex:1;min-width:280px}.bv-detail .wiring-card h3{text-align:center;font-size:16px;margin:0 0 10px}.bv-detail .control-callout{margin:0 0 24px;padding:18px 20px 8px;border-left:4px solid #78b72a;background:#f4f8ee}.bv-detail .control-callout h3{margin:0 0 12px;font-size:17px;color:#16220c}.bv-detail .control-callout ul{margin:0;padding-left:20px}.bv-detail .control-callout li{margin-bottom:9px}.bv-detail .spec-scroll{width:100%;overflow-x:auto;overflow-y:hidden;margin:0 0 20px;-webkit-overflow-scrolling:touch}.bv-detail .spec-scroll table{width:100%;border-collapse:collapse;background:#fff;margin:0}.bv-detail tr{border-bottom:1px dashed #000}.bv-detail th,.bv-detail td{padding:10px;text-align:left;font-size:15px;vertical-align:top}.bv-detail th{width:20%;background:#f0f0f0;font-weight:bold}.bv-detail .faq-q{font-weight:bold;margin:16px 0 5px}.bv-detail .faq-a{margin:0 0 16px;padding-left:15px}.bv-detail a{color:#0066cc;text-decoration:underline}@media(max-width:600px){.bv-detail .desktop-img{display:none!important}.bv-detail .mobile-img{display:block!important}.bv-detail h2{font-size:20px;font-weight:700}.bv-detail p,.bv-detail li{font-size:15px}.bv-detail .wiring-grid{display:block}.bv-detail .wiring-card{margin-bottom:15px}.bv-detail .control-callout{padding:15px 14px 6px}.bv-detail .control-callout h3{font-size:16px}.bv-detail .spec-scroll table{min-width:680px}.bv-detail th,.bv-detail td{padding:8px 9px;font-size:14px;white-space:normal}}\u003c\/style\u003e\n\u003cdiv class=\"bv-detail\"\u003e\n\u003cdiv class=\"image-pair\"\u003e\n\u003cimg class=\"desktop-img\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/e448011edd64412b090515ded8262a19.jpg?v=1780117738\" alt=\"USS-HDBV00035 product image\"\u003e\u003cimg class=\"mobile-img\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/e448011edd64412b090515ded8262a19.jpg?v=1780117738\" alt=\"USS-HDBV00035 product image\"\u003e\n\u003c\/div\u003e\n\u003ch2\u003eINTRODUCTION\u003c\/h2\u003e\n\u003cp\u003eThis premium flow control solution integrates a heavy-duty 3-piece stainless steel ball valve with a high-performance electric actuator. Engineered for reliability and precision, it provides a comprehensive hardware suite for automated systems, offering superior durability, seamless integration, and simplified maintenance in demanding industrial environments.\u003c\/p\u003e\n\u003ch2\u003eFEATURES\u003c\/h2\u003e\n\u003cdiv class=\"image-pair\"\u003e\n\u003cimg class=\"desktop-img\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/ig_091236ea01646e01016a1fc6106344819babe6cfa61e9ff177.png?v=1780468642\" alt=\"USS-HDBV00035 features\"\u003e\u003cimg class=\"mobile-img\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/ig_091236ea01646e01016a1fc6106344819babe6cfa61e9ff177.png?v=1780468642\" alt=\"USS-HDBV00035 features\"\u003e\n\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePremium Material Construction:\u003c\/strong\u003e Crafted from high-grade 304 stainless steel, the valve body is highly resistant to corrosion, making it suitable for handling weak acids, weak alkalis, chemical solvents, and water.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaintenance-Friendly 3-Piece Design:\u003c\/strong\u003e The innovative 3-piece body construction allows for seamless in-line maintenance. Internal components can be cleaned or replaced without disconnecting the pipes, helping reduce downtime and service costs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Pressure \u0026amp; Full-Bore Efficiency:\u003c\/strong\u003e The full-bore configuration helps minimize pressure drop and maintain efficient flow capacity in high-pressure systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSmart Automation Ready:\u003c\/strong\u003e Integrated limit switches and position feedback support PLC integration, remote control, real-time monitoring, and automated operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Torque Reliability:\u003c\/strong\u003e A compact, heavy-duty motor delivers steady 50 Nm torque for reliable full-port operation and drop-tight sealing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnhanced Safety \u0026amp; Self-Locking:\u003c\/strong\u003e The actuator features a self-locking mechanism for stable operation and a manual override port for controlled intervention during power outages or emergencies.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRugged Outdoor Durability:\u003c\/strong\u003e A powder-coated polyester aluminum housing provides resistance to corrosion and harsh weather conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdvanced Circuitry Protection:\u003c\/strong\u003e The internal PCBA is treated with a protective sealant to help prevent damage from moisture, condensation, and short circuits.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eAPPLICATIONS\u003c\/h2\u003e\n\u003cdiv class=\"image-pair\"\u003e\n\u003cimg class=\"desktop-img\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/Application_d83d7c67-93f0-46dd-bb8d-c1c7a38e6775.png?v=1779780603\" alt=\"USS-HDBV00035 applications\"\u003e\u003cimg class=\"mobile-img\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/Application_d83d7c67-93f0-46dd-bb8d-c1c7a38e6775.png?v=1779780603\" alt=\"USS-HDBV00035 applications\"\u003e\n\u003c\/div\u003e\n\u003ch2\u003eWIRING DIAGRAMS\u003c\/h2\u003e\n\u003cdiv class=\"wiring-grid\"\u003e\n\u003cdiv class=\"wiring-card\"\u003e\n\u003cdiv class=\"image-pair\"\u003e\n\u003cimg class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/ef.jpg\" alt=\"Wiring diagram A\"\u003e\u003cimg class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/ef.jpg\" alt=\"Wiring diagram A\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"wiring-card\"\u003e\n\u003cdiv class=\"image-pair\"\u003e\n\u003cimg class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/IJ.jpg\" alt=\"Wiring diagram B\"\u003e\u003cimg class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/IJ.jpg\" alt=\"Wiring diagram B\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"control-callout\"\u003e\n\u003ch3\u003eTYPE E: Modulating Type with Integrated Servo Controller\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMulti-Signal Modulating Control:\u003c\/strong\u003e Accepts 4-20 mA, 1-5V, or 0-10V DC input signals to automatically position the valve at the required flow setting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated Electronic Servo Controller:\u003c\/strong\u003e The built-in servo controller continuously adjusts valve position in response to the incoming control signal.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e4-20 mA Position Feedback:\u003c\/strong\u003e Provides a 4-20 mA output signal for compatible PLC, DCS, or process control systems to monitor actual valve position.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClosed-Loop Position Sensing:\u003c\/strong\u003e An integrated 1 kΩ potentiometer provides position feedback for accurate, stable modulation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC Power Input:\u003c\/strong\u003e Uses B1 (L) and B2 (N) terminals for the AC power supply connection, as shown in the wiring diagram.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch2\u003eSPECIFICATIONS\u003c\/h2\u003e\n\u003cdiv class=\"spec-scroll\" role=\"region\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr style=\"border-bottom: 1px dashed #000000;\"\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003eUSS-HDBV00035\u003c\/td\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003eU.S. Solid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed #000000;\"\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eSize\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003e1 1\/2\"\u003c\/td\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eWiring Type\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003eType E: Modulating Type with Integrated Servo Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed #000000;\"\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eValve Material\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003e304SS\u003c\/td\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eBall Seal\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003ePTFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed #000000;\"\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eOperating Time\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003e30 Seconds\u003c\/td\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eWorking Voltage\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003e110V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed #000000;\"\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eMax Power\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003e30 W\u003c\/td\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eMax Torque\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003e100 N m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed #000000;\"\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eMax Medium Pressure\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003e1.6 Mpa\u003c\/td\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003e-30°C to 180°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed #000000;\"\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eLife Expectancy\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003e30,000 to 50,000 Cycles\u003c\/td\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eBore Type\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003eFull port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed #000000;\"\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eThread Type\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003eNPT\u003c\/td\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eOperating State\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003eRemain in position\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed #000000;\"\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003e-30°C to 60°C\u003c\/td\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eEnclosure Rating\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch2\u003eWARNINGS\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Failure Behavior:\u003c\/strong\u003e This valve remains in its current position during a power outage. It does not automatically return to a preset position.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Match Required:\u003c\/strong\u003e Supply voltage must match the actuator rating exactly. Incorrect voltage may permanently damage the unit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDedicated Power Circuit:\u003c\/strong\u003e Each actuator requires its own fuse-protected power supply. Do not connect multiple actuators in parallel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDisconnect Power Before Service:\u003c\/strong\u003e Always disconnect power before wiring, maintenance, or using the manual override.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP65 Weather Resistant:\u003c\/strong\u003e Suitable for outdoor use, but additional protection is recommended for permanent outdoor installations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow Power Consumption:\u003c\/strong\u003e Power is only used during opening and closing. No power is consumed when fully open or fully closed.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProfessional Installation Recommended:\u003c\/strong\u003e Installation should be performed by qualified personnel familiar with electrical control systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003cp class=\"faq-q\"\u003e1. Can I manually operate the valve?\u003c\/p\u003e\n\u003cp class=\"faq-a\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes. The actuator features a manual override. We recommend manually cycling the valve before installation to verify smooth operation and using the adjustment screws during commissioning to fine-tune the open and closed positions.\u003c\/p\u003e\n\u003cp class=\"faq-q\"\u003e2. Can this valve be installed outdoors?\u003c\/p\u003e\n\u003cp class=\"faq-a\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes, depending on the model's IP rating. While our heavy-duty actuators are weather-resistant, we recommend using a protective cover or shelter for permanent outdoor installations to protect the unit from direct UV exposure and ice buildup.\u003c\/p\u003e\n\u003cp class=\"faq-q\"\u003e3. Is this valve suitable for high-viscosity fluids or particulates?\u003c\/p\u003e\n\u003cp class=\"faq-a\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes, subject to torque considerations. Extremely viscous media or large particulates increase resistance, so ensure the operating torque remains within the actuator's rated capacity to prevent stalling.\u003c\/p\u003e\n\u003cp class=\"faq-q\"\u003e4. Is it normal for the actuator to feel hot during operation?\u003c\/p\u003e\n\u003cp class=\"faq-a\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes. The actuator may feel warm during continuous cycling. If the housing becomes too hot to touch, check that the recommended duty cycle and ambient temperature range of -30°C to 60°C are not exceeded.\u003c\/p\u003e\n\u003cp class=\"faq-q\"\u003e5. Can I wire multiple actuators in parallel on the same circuit?\u003c\/p\u003e\n\u003cp class=\"faq-a\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e No. Each motorized actuator should use its own dedicated, fuse-protected power supply to ensure proper signal response and reduce the risk of electrical interference or damage.\u003c\/p\u003e\n\u003cp style=\"margin-top: 25px;\"\u003eDownload user manual \u003ca href=\"http:\/\/file.ussolid.com\/content\/JFHDBV\/JFHDBV-%20Electric%20Actuated%20Ball%20Valve%20instruction%20manual.pdf\" rel=\"noopener\" target=\"_blank\"\u003ehere\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"U.S. Solid","offers":[{"title":"Default Title","offer_id":50550694084863,"sku":"JFHDBV00035","price":509.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/2_1792d9c1-5082-4238-af11-3dad3d453610.jpg?v=1778312904"},{"product_id":"1-2-modulating-electric-ball-valve-24v-dc-heavy-duty-3-piece-304-ss-industrial-ball-valve-4-20ma-proportional-control-with-position-feedback","title":"1\/2\" Modulating Electric Ball Valve,24V DC Heavy Duty 3-Piece 304 SS Industrial Ball Valve, 4-20mA Proportional Control with Position Feedback","description":"\u003cstyle\u003e.bv-detail{font-family:Arial,sans-serif;color:#000;line-height:1.62}.bv-detail .desktop-img{display:block}.bv-detail .mobile-img{display:none}.bv-detail img{width:100%;max-width:100%;height:auto;display:block}.bv-detail h2{font-size:22px;font-weight:700;margin:25px 0 10px}.bv-detail p,.bv-detail li{font-size:16px}.bv-detail .image-pair{margin:0 0 20px}.bv-detail .wiring-grid{display:flex;flex-wrap:wrap;justify-content:center;gap:15px;margin-bottom:20px}.bv-detail .wiring-card{flex:0 1 760px;min-width:0}.bv-detail .wiring-card .image-pair{display:flex;justify-content:center;align-items:center}.bv-detail .wiring-card .image-pair img{width:auto;max-width:100%;margin:0 auto 16px!important;float:none!important}.bv-detail .wiring-card h3{text-align:center;font-size:16px;margin:0 0 10px}.bv-detail .control-callout{margin:0 0 24px;padding:18px 20px 8px;border-left:4px solid #78b72a;background:#f4f8ee}.bv-detail .control-callout h3{margin:0 0 12px;font-size:17px;color:#16220c}.bv-detail .control-callout ul{margin:0;padding-left:20px}.bv-detail .control-callout li{margin-bottom:9px}.bv-detail .spec-scroll{width:100%;overflow-x:auto;overflow-y:hidden;margin:0 0 20px;-webkit-overflow-scrolling:touch}.bv-detail .spec-scroll table{width:100%;border-collapse:collapse;background:#fff;margin:0}.bv-detail tr{border-bottom:1px dashed #000}.bv-detail th,.bv-detail td{padding:10px;text-align:left;font-size:15px;vertical-align:top}.bv-detail th{width:20%;background:#f0f0f0;font-weight:bold}.bv-detail .faq-q{font-weight:bold;margin:16px 0 5px}.bv-detail .faq-a{margin:0 0 16px;padding-left:15px}.bv-detail a{color:#0066cc;text-decoration:underline}@media(max-width:600px){.bv-detail .desktop-img{display:none!important}.bv-detail .mobile-img{display:block!important}.bv-detail h2{font-size:20px;font-weight:700}.bv-detail p,.bv-detail li{font-size:15px}.bv-detail .wiring-grid{display:block}.bv-detail .wiring-card{margin-bottom:15px}.bv-detail .control-callout{padding:15px 14px 6px}.bv-detail .control-callout h3{font-size:16px}.bv-detail .spec-scroll table{min-width:680px}.bv-detail th,.bv-detail td{padding:8px 9px;font-size:14px;white-space:normal}}\u003c\/style\u003e\n\u003cdiv class=\"bv-detail\"\u003e\n\u003cdiv class=\"image-pair\"\u003e\n\u003cimg class=\"desktop-img\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/e448011edd64412b090515ded8262a19.jpg?v=1780117738\" alt=\"USS-HDBV00041 product image\"\u003e\u003cimg class=\"mobile-img\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/e448011edd64412b090515ded8262a19.jpg?v=1780117738\" alt=\"USS-HDBV00041 product image\"\u003e\n\u003c\/div\u003e\n\u003ch2\u003eINTRODUCTION\u003c\/h2\u003e\n\u003cp\u003eThis premium flow control solution integrates a heavy-duty 3-piece stainless steel ball valve with a high-performance electric actuator. Engineered for reliability and precision, it provides a comprehensive hardware suite for automated systems, offering superior durability, seamless integration, and simplified maintenance in demanding industrial environments.\u003c\/p\u003e\n\u003ch2\u003eFEATURES\u003c\/h2\u003e\n\u003cdiv class=\"image-pair\"\u003e\n\u003cimg class=\"desktop-img\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/ig_091236ea01646e01016a1fc6106344819babe6cfa61e9ff177.png?v=1780468642\" alt=\"USS-HDBV00041 features\"\u003e\u003cimg class=\"mobile-img\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/ig_091236ea01646e01016a1fc6106344819babe6cfa61e9ff177.png?v=1780468642\" alt=\"USS-HDBV00041 features\"\u003e\n\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePremium Material Construction:\u003c\/strong\u003e Crafted from high-grade 304 stainless steel, the valve body is highly resistant to corrosion, making it suitable for handling weak acids, weak alkalis, chemical solvents, and water.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaintenance-Friendly 3-Piece Design:\u003c\/strong\u003e The innovative 3-piece body construction allows for seamless in-line maintenance. Internal components can be cleaned or replaced without disconnecting the pipes, helping reduce downtime and service costs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Pressure \u0026amp; Full-Bore Efficiency:\u003c\/strong\u003e The full-bore configuration helps minimize pressure drop and maintain efficient flow capacity in high-pressure systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSmart Automation Ready:\u003c\/strong\u003e Integrated limit switches and position feedback support PLC integration, remote control, real-time monitoring, and automated operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Torque Reliability:\u003c\/strong\u003e A compact, heavy-duty motor delivers steady 50 Nm torque for reliable full-port operation and drop-tight sealing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnhanced Safety \u0026amp; Self-Locking:\u003c\/strong\u003e The actuator features a self-locking mechanism for stable operation and a manual override port for controlled intervention during power outages or emergencies.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRugged Outdoor Durability:\u003c\/strong\u003e A powder-coated polyester aluminum housing provides resistance to corrosion and harsh weather conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdvanced Circuitry Protection:\u003c\/strong\u003e The internal PCBA is treated with a protective sealant to help prevent damage from moisture, condensation, and short circuits.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eAPPLICATIONS\u003c\/h2\u003e\n\u003cdiv class=\"image-pair\"\u003e\n\u003cimg class=\"desktop-img\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/Application_d83d7c67-93f0-46dd-bb8d-c1c7a38e6775.png?v=1779780603\" alt=\"USS-HDBV00041 applications\"\u003e\u003cimg class=\"mobile-img\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/Application_d83d7c67-93f0-46dd-bb8d-c1c7a38e6775.png?v=1779780603\" alt=\"USS-HDBV00041 applications\"\u003e\n\u003c\/div\u003e\n\u003ch2\u003eWIRING DIAGRAMS\u003c\/h2\u003e\n\u003cdiv class=\"wiring-grid\"\u003e\n\u003cdiv class=\"wiring-card\"\u003e\n\u003cdiv class=\"image-pair\" style=\"text-align: center;\"\u003e\n\u003cimg class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/DC24V-modulate-wiring.png\" alt=\"Wiring diagram A\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003cimg class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/DC24V-modulate-wiring.png\" alt=\"Wiring diagram A\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"control-callout\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eMulti-Signal Modulating Control:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Accepts 4–20 mA input signals for automatic valve positioning. \u003c\/span\u003e\u003cem\u003e\u003cspan\u003e(1–5 V or 0–10 VDC input available for customization.)\u003c\/span\u003e\u003c\/em\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrecise 4–20 mA Modulating Control:\u003c\/strong\u003e Receive a standard 4–20 mA control signal and automatically position the valve for smooth, reliable flow regulation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomatic Electronic Positioning:\u003c\/strong\u003e The electronic positioner continuously compares the commanded setting with the actual valve position, then adjusts the actuator as needed to maintain the target opening.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReal-Time 4–20 mA Position Feedback:\u003c\/strong\u003e Send actual valve-position feedback to a compatible PLC, DCS, or process controller for convenient remote monitoring and control verification.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClosed-Loop Position Accuracy:\u003c\/strong\u003e A three-wire position feedback potentiometer continuously tracks valve travel, helping deliver stable, repeatable modulation across the full 0–100% stroke.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e24 VDC Power Supply:\u003c\/strong\u003e Designed for 24 VDC operation, with clearly marked positive (`+`) and negative (`−`) power terminals for straightforward installation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch2\u003eSPECIFICATIONS\u003c\/h2\u003e\n\u003cdiv class=\"spec-scroll\" role=\"region\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr style=\"border-bottom: 1px dashed #000000;\"\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003eUSS-HDBV00041\u003c\/td\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003eU.S. Solid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed #000000;\"\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eSize\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003e1\/2\"\u003c\/td\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eWiring Type\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003eType E: Modulating Type with Integrated Servo Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed #000000;\"\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eValve Material\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003e304SS\u003c\/td\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eBall Seal\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003ePTFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed #000000;\"\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eOperating Time\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003e8 Seconds\u003c\/td\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eWorking Voltage\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003e24V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed #000000;\"\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eMax Power\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003e9.5 W\u003c\/td\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eMax Torque\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003e50 N m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed #000000;\"\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eMax Medium Pressure\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003e1.6 Mpa\u003c\/td\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003e-30°C to 180°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed #000000;\"\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eLife Expectancy\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003e30,000 to 50,000 Cycles\u003c\/td\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eBore Type\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003eFull port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed #000000;\"\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eThread Type\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003eNPT\u003c\/td\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eOperating State\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003eRemain in position\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed #000000;\"\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003e-30°C to 60°C\u003c\/td\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eEnclosure Rating\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch2\u003eWARNINGS\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Failure Behavior:\u003c\/strong\u003e This valve remains in its current position during a power outage. It does not automatically return to a preset position.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Match Required:\u003c\/strong\u003e Supply voltage must match the actuator rating exactly. Incorrect voltage may permanently damage the unit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDedicated Power Circuit:\u003c\/strong\u003e Each actuator requires its own fuse-protected power supply. Do not connect multiple actuators in parallel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDisconnect Power Before Service:\u003c\/strong\u003e Always disconnect power before wiring, maintenance, or using the manual override.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP65 Weather Resistant:\u003c\/strong\u003e Suitable for outdoor use, but additional protection is recommended for permanent outdoor installations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow Power Consumption:\u003c\/strong\u003e Power is only used during opening and closing. No power is consumed when fully open or fully closed.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProfessional Installation Recommended:\u003c\/strong\u003e Installation should be performed by qualified personnel familiar with electrical control systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003cp class=\"faq-q\"\u003e1. Can I manually operate the valve?\u003c\/p\u003e\n\u003cp class=\"faq-a\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes. The actuator features a manual override. We recommend manually cycling the valve before installation to verify smooth operation and using the adjustment screws during commissioning to fine-tune the open and closed positions.\u003c\/p\u003e\n\u003cp class=\"faq-q\"\u003e2. Can this valve be installed outdoors?\u003c\/p\u003e\n\u003cp class=\"faq-a\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes, depending on the model's IP rating. While our heavy-duty actuators are weather-resistant, we recommend using a protective cover or shelter for permanent outdoor installations to protect the unit from direct UV exposure and ice buildup.\u003c\/p\u003e\n\u003cp class=\"faq-q\"\u003e3. Is this valve suitable for high-viscosity fluids or particulates?\u003c\/p\u003e\n\u003cp class=\"faq-a\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes, subject to torque considerations. Extremely viscous media or large particulates increase resistance, so ensure the operating torque remains within the actuator's rated capacity to prevent stalling.\u003c\/p\u003e\n\u003cp class=\"faq-q\"\u003e4. Is it normal for the actuator to feel hot during operation?\u003c\/p\u003e\n\u003cp class=\"faq-a\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes. The actuator may feel warm during continuous cycling. If the housing becomes too hot to touch, check that the recommended duty cycle and ambient temperature range of -30°C to 60°C are not exceeded.\u003c\/p\u003e\n\u003cp class=\"faq-q\"\u003e5. Can I wire multiple actuators in parallel on the same circuit?\u003c\/p\u003e\n\u003cp class=\"faq-a\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e No. Each motorized actuator should use its own dedicated, fuse-protected power supply to ensure proper signal response and reduce the risk of electrical interference or damage.\u003c\/p\u003e\n\u003cp style=\"margin-top: 25px;\"\u003eDownload user manual \u003ca href=\"http:\/\/file.ussolid.com\/content\/JFHDBV\/JFHDBV-%20Electric%20Actuated%20Ball%20Valve%20instruction%20manual.pdf\" rel=\"noopener\" target=\"_blank\"\u003ehere\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n","brand":"U.S. Solid","offers":[{"title":"Default Title","offer_id":50550694150399,"sku":"JFHDBV00041","price":379.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/1_8d4a459f-d9ac-445c-8d67-43464737da94.jpg?v=1783583063"},{"product_id":"3-4-modulating-electric-ball-valve-24v-dc-heavy-duty-3-piece-304-ss-industrial-ball-valve-4-20ma-proportional-control-with-position-feedback","title":"3\/4\" Modulating Electric Ball Valve,24V DC Heavy Duty 3-Piece 304 SS Industrial Ball Valve, 4-20mA Proportional Control with Position Feedback","description":"\u003cstyle\u003e.bv-detail{font-family:Arial,sans-serif;color:#000;line-height:1.62}.bv-detail .desktop-img{display:block}.bv-detail .mobile-img{display:none}.bv-detail img{width:100%;max-width:100%;height:auto;display:block}.bv-detail h2{font-size:22px;font-weight:700;margin:25px 0 10px}.bv-detail p,.bv-detail li{font-size:16px}.bv-detail .image-pair{margin:0 0 20px}.bv-detail .wiring-grid{display:flex;flex-wrap:wrap;justify-content:center;gap:15px;margin-bottom:20px}.bv-detail .wiring-card{flex:0 1 760px;min-width:0}.bv-detail .wiring-card .image-pair{display:flex;justify-content:center;align-items:center}.bv-detail .wiring-card .image-pair img{width:auto;max-width:100%;margin:0 auto 16px!important;float:none!important}.bv-detail .wiring-card h3{text-align:center;font-size:16px;margin:0 0 10px}.bv-detail .control-callout{margin:0 0 24px;padding:18px 20px 8px;border-left:4px solid #78b72a;background:#f4f8ee}.bv-detail .control-callout h3{margin:0 0 12px;font-size:17px;color:#16220c}.bv-detail .control-callout ul{margin:0;padding-left:20px}.bv-detail .control-callout li{margin-bottom:9px}.bv-detail .spec-scroll{width:100%;overflow-x:auto;overflow-y:hidden;margin:0 0 20px;-webkit-overflow-scrolling:touch}.bv-detail .spec-scroll table{width:100%;border-collapse:collapse;background:#fff;margin:0}.bv-detail tr{border-bottom:1px dashed #000}.bv-detail th,.bv-detail td{padding:10px;text-align:left;font-size:15px;vertical-align:top}.bv-detail th{width:20%;background:#f0f0f0;font-weight:bold}.bv-detail .faq-q{font-weight:bold;margin:16px 0 5px}.bv-detail .faq-a{margin:0 0 16px;padding-left:15px}.bv-detail a{color:#0066cc;text-decoration:underline}@media(max-width:600px){.bv-detail .desktop-img{display:none!important}.bv-detail .mobile-img{display:block!important}.bv-detail h2{font-size:20px;font-weight:700}.bv-detail p,.bv-detail li{font-size:15px}.bv-detail .wiring-grid{display:block}.bv-detail .wiring-card{margin-bottom:15px}.bv-detail .control-callout{padding:15px 14px 6px}.bv-detail .control-callout h3{font-size:16px}.bv-detail .spec-scroll table{min-width:680px}.bv-detail th,.bv-detail td{padding:8px 9px;font-size:14px;white-space:normal}}\u003c\/style\u003e\n\u003cdiv class=\"bv-detail\"\u003e\n\u003cdiv class=\"image-pair\"\u003e\n\u003cimg class=\"desktop-img\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/e448011edd64412b090515ded8262a19.jpg?v=1780117738\" alt=\"USS-HDBV00042 product image\"\u003e\u003cimg class=\"mobile-img\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/e448011edd64412b090515ded8262a19.jpg?v=1780117738\" alt=\"USS-HDBV00042 product image\"\u003e\n\u003c\/div\u003e\n\u003ch2\u003eINTRODUCTION\u003c\/h2\u003e\n\u003cp\u003eThis premium flow control solution integrates a heavy-duty 3-piece stainless steel ball valve with a high-performance electric actuator. Engineered for reliability and precision, it provides a comprehensive hardware suite for automated systems, offering superior durability, seamless integration, and simplified maintenance in demanding industrial environments.\u003c\/p\u003e\n\u003ch2\u003eFEATURES\u003c\/h2\u003e\n\u003cdiv class=\"image-pair\"\u003e\n\u003cimg class=\"desktop-img\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/ig_091236ea01646e01016a1fc6106344819babe6cfa61e9ff177.png?v=1780468642\" alt=\"USS-HDBV00042 features\"\u003e\u003cimg class=\"mobile-img\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/ig_091236ea01646e01016a1fc6106344819babe6cfa61e9ff177.png?v=1780468642\" alt=\"USS-HDBV00042 features\"\u003e\n\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePremium Material Construction:\u003c\/strong\u003e Crafted from high-grade 304 stainless steel, the valve body is highly resistant to corrosion, making it suitable for handling weak acids, weak alkalis, chemical solvents, and water.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaintenance-Friendly 3-Piece Design:\u003c\/strong\u003e The innovative 3-piece body construction allows for seamless in-line maintenance. Internal components can be cleaned or replaced without disconnecting the pipes, helping reduce downtime and service costs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Pressure \u0026amp; Full-Bore Efficiency:\u003c\/strong\u003e The full-bore configuration helps minimize pressure drop and maintain efficient flow capacity in high-pressure systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSmart Automation Ready:\u003c\/strong\u003e Integrated limit switches and position feedback support PLC integration, remote control, real-time monitoring, and automated operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Torque Reliability:\u003c\/strong\u003e A compact, heavy-duty motor delivers steady 50 Nm torque for reliable full-port operation and drop-tight sealing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnhanced Safety \u0026amp; Self-Locking:\u003c\/strong\u003e The actuator features a self-locking mechanism for stable operation and a manual override port for controlled intervention during power outages or emergencies.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRugged Outdoor Durability:\u003c\/strong\u003e A powder-coated polyester aluminum housing provides resistance to corrosion and harsh weather conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdvanced Circuitry Protection:\u003c\/strong\u003e The internal PCBA is treated with a protective sealant to help prevent damage from moisture, condensation, and short circuits.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eAPPLICATIONS\u003c\/h2\u003e\n\u003cdiv class=\"image-pair\"\u003e\n\u003cimg class=\"desktop-img\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/Application_d83d7c67-93f0-46dd-bb8d-c1c7a38e6775.png?v=1779780603\" alt=\"USS-HDBV00042 applications\"\u003e\u003cimg class=\"mobile-img\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/Application_d83d7c67-93f0-46dd-bb8d-c1c7a38e6775.png?v=1779780603\" alt=\"USS-HDBV00042 applications\"\u003e\n\u003c\/div\u003e\n\u003ch2\u003eWIRING DIAGRAMS\u003c\/h2\u003e\n\u003cdiv class=\"wiring-grid\"\u003e\n\u003cdiv class=\"wiring-card\"\u003e\n\u003cdiv class=\"image-pair\"\u003e\n\u003cimg class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/DC24V-modulate-wiring.png\" alt=\"Wiring diagram A\"\u003e\u003cimg class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/DC24V-modulate-wiring.png\" alt=\"Wiring diagram A\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"control-callout\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMulti-Signal Modulating Control:\u003c\/strong\u003e Accepts 4-20 mA, 1-5V, or 0-10V DC input signals to automatically\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrecise 4–20 mA Modulating Control:\u003c\/strong\u003e Receive a standard 4–20 mA control signal and automatically position the valve for smooth, reliable flow regulation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomatic Electronic Positioning:\u003c\/strong\u003e The electronic positioner continuously compares the commanded setting with the actual valve position, then adjusts the actuator as needed to maintain the target opening.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReal-Time 4–20 mA Position Feedback:\u003c\/strong\u003e Send actual valve-position feedback to a compatible PLC, DCS, or process controller for convenient remote monitoring and control verification.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClosed-Loop Position Accuracy:\u003c\/strong\u003e A three-wire position feedback potentiometer continuously tracks valve travel, helping deliver stable, repeatable modulation across the full 0–100% stroke.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e24 VDC Power Supply:\u003c\/strong\u003e Designed for 24 VDC operation, with clearly marked positive (`+`) and negative (`−`) power terminals for straightforward installation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch2\u003eSPECIFICATIONS\u003c\/h2\u003e\n\u003cdiv class=\"spec-scroll\" role=\"region\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr style=\"border-bottom: 1px dashed #000000;\"\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003eUSS-HDBV00042\u003c\/td\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003eU.S. Solid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed #000000;\"\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eSize\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003e3\/4\"\u003c\/td\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eWiring Type\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003eType E: Modulating Type with Integrated Servo Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed #000000;\"\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eValve Material\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003e304SS\u003c\/td\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eBall Seal\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003ePTFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed #000000;\"\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eOperating Time\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003e8 Seconds\u003c\/td\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eWorking Voltage\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003e24V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed #000000;\"\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eMax Power\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003e9.5 W\u003c\/td\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eMax Torque\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003e50 N m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed #000000;\"\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eMax Medium Pressure\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003e1.6 Mpa\u003c\/td\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003e-30°C to 180°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed #000000;\"\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eLife Expectancy\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003e30,000 to 50,000 Cycles\u003c\/td\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eBore Type\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003eFull port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed #000000;\"\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eThread Type\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003eNPT\u003c\/td\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eOperating State\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003eRemain in position\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed #000000;\"\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003e-30°C to 60°C\u003c\/td\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eEnclosure Rating\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch2\u003eWARNINGS\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Failure Behavior:\u003c\/strong\u003e This valve remains in its current position during a power outage. It does not automatically return to a preset position.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Match Required:\u003c\/strong\u003e Supply voltage must match the actuator rating exactly. Incorrect voltage may permanently damage the unit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDedicated Power Circuit:\u003c\/strong\u003e Each actuator requires its own fuse-protected power supply. Do not connect multiple actuators in parallel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDisconnect Power Before Service:\u003c\/strong\u003e Always disconnect power before wiring, maintenance, or using the manual override.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP65 Weather Resistant:\u003c\/strong\u003e Suitable for outdoor use, but additional protection is recommended for permanent outdoor installations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow Power Consumption:\u003c\/strong\u003e Power is only used during opening and closing. No power is consumed when fully open or fully closed.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProfessional Installation Recommended:\u003c\/strong\u003e Installation should be performed by qualified personnel familiar with electrical control systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003cp class=\"faq-q\"\u003e1. Can I manually operate the valve?\u003c\/p\u003e\n\u003cp class=\"faq-a\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes. The actuator features a manual override. We recommend manually cycling the valve before installation to verify smooth operation and using the adjustment screws during commissioning to fine-tune the open and closed positions.\u003c\/p\u003e\n\u003cp class=\"faq-q\"\u003e2. Can this valve be installed outdoors?\u003c\/p\u003e\n\u003cp class=\"faq-a\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes, depending on the model's IP rating. While our heavy-duty actuators are weather-resistant, we recommend using a protective cover or shelter for permanent outdoor installations to protect the unit from direct UV exposure and ice buildup.\u003c\/p\u003e\n\u003cp class=\"faq-q\"\u003e3. Is this valve suitable for high-viscosity fluids or particulates?\u003c\/p\u003e\n\u003cp class=\"faq-a\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes, subject to torque considerations. Extremely viscous media or large particulates increase resistance, so ensure the operating torque remains within the actuator's rated capacity to prevent stalling.\u003c\/p\u003e\n\u003cp class=\"faq-q\"\u003e4. Is it normal for the actuator to feel hot during operation?\u003c\/p\u003e\n\u003cp class=\"faq-a\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes. The actuator may feel warm during continuous cycling. If the housing becomes too hot to touch, check that the recommended duty cycle and ambient temperature range of -30°C to 60°C are not exceeded.\u003c\/p\u003e\n\u003cp class=\"faq-q\"\u003e5. Can I wire multiple actuators in parallel on the same circuit?\u003c\/p\u003e\n\u003cp class=\"faq-a\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e No. Each motorized actuator should use its own dedicated, fuse-protected power supply to ensure proper signal response and reduce the risk of electrical interference or damage.\u003c\/p\u003e\n\u003cp style=\"margin-top: 25px;\"\u003eDownload user manual \u003ca href=\"http:\/\/file.ussolid.com\/content\/JFHDBV\/JFHDBV-%20Electric%20Actuated%20Ball%20Valve%20instruction%20manual.pdf\" rel=\"noopener\" target=\"_blank\"\u003ehere\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n","brand":"U.S. Solid","offers":[{"title":"Default Title","offer_id":50550694183167,"sku":"JFHDBV00042","price":389.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/1_b2626ae7-6d89-400c-ba44-a286dabb8128.jpg?v=1783587825"},{"product_id":"1-modulating-electric-ball-valve-24v-dc-heavy-duty-3-piece-304-ss-industrial-ball-valve-4-20ma-proportional-control-with-position-feedback","title":"1\" Modulating Electric Ball Valve,24V DC Heavy Duty 3-Piece 304 SS Industrial Ball Valve, 4-20mA Proportional Control with Position Feedback","description":"\u003cstyle\u003e.bv-detail{font-family:Arial,sans-serif;color:#000;line-height:1.62}.bv-detail .desktop-img{display:block}.bv-detail .mobile-img{display:none}.bv-detail img{width:100%;max-width:100%;height:auto;display:block}.bv-detail h2{font-size:22px;font-weight:700;margin:25px 0 10px}.bv-detail p,.bv-detail li{font-size:16px}.bv-detail .image-pair{margin:0 0 20px}.bv-detail .wiring-grid{display:flex;flex-wrap:wrap;justify-content:center;gap:15px;margin-bottom:20px}.bv-detail .wiring-card{flex:0 1 760px;min-width:0}.bv-detail .wiring-card .image-pair{display:flex;justify-content:center;align-items:center}.bv-detail .wiring-card .image-pair img{width:auto;max-width:100%;margin:0 auto 16px!important;float:none!important}.bv-detail .wiring-card h3{text-align:center;font-size:16px;margin:0 0 10px}.bv-detail .control-callout{margin:0 0 24px;padding:18px 20px 8px;border-left:4px solid #78b72a;background:#f4f8ee}.bv-detail .control-callout h3{margin:0 0 12px;font-size:17px;color:#16220c}.bv-detail .control-callout ul{margin:0;padding-left:20px}.bv-detail .control-callout li{margin-bottom:9px}.bv-detail .spec-scroll{width:100%;overflow-x:auto;overflow-y:hidden;margin:0 0 20px;-webkit-overflow-scrolling:touch}.bv-detail .spec-scroll table{width:100%;border-collapse:collapse;background:#fff;margin:0}.bv-detail tr{border-bottom:1px dashed #000}.bv-detail th,.bv-detail td{padding:10px;text-align:left;font-size:15px;vertical-align:top}.bv-detail th{width:20%;background:#f0f0f0;font-weight:bold}.bv-detail .faq-q{font-weight:bold;margin:16px 0 5px}.bv-detail .faq-a{margin:0 0 16px;padding-left:15px}.bv-detail a{color:#0066cc;text-decoration:underline}@media(max-width:600px){.bv-detail .desktop-img{display:none!important}.bv-detail .mobile-img{display:block!important}.bv-detail h2{font-size:20px;font-weight:700}.bv-detail p,.bv-detail li{font-size:15px}.bv-detail .wiring-grid{display:block}.bv-detail .wiring-card{margin-bottom:15px}.bv-detail .control-callout{padding:15px 14px 6px}.bv-detail .control-callout h3{font-size:16px}.bv-detail .spec-scroll table{min-width:680px}.bv-detail th,.bv-detail td{padding:8px 9px;font-size:14px;white-space:normal}}\u003c\/style\u003e\n\u003cdiv class=\"bv-detail\"\u003e\n\u003cdiv class=\"image-pair\"\u003e\n\u003cimg class=\"desktop-img\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/e448011edd64412b090515ded8262a19.jpg?v=1780117738\" alt=\"USS-HDBV00043 product image\"\u003e\u003cimg class=\"mobile-img\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/e448011edd64412b090515ded8262a19.jpg?v=1780117738\" alt=\"USS-HDBV00043 product image\"\u003e\n\u003c\/div\u003e\n\u003ch2\u003eINTRODUCTION\u003c\/h2\u003e\n\u003cp\u003eThis premium flow control solution integrates a heavy-duty 3-piece stainless steel ball valve with a high-performance electric actuator. Engineered for reliability and precision, it provides a comprehensive hardware suite for automated systems, offering superior durability, seamless integration, and simplified maintenance in demanding industrial environments.\u003c\/p\u003e\n\u003ch2\u003eFEATURES\u003c\/h2\u003e\n\u003cdiv class=\"image-pair\"\u003e\n\u003cimg class=\"desktop-img\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/ig_091236ea01646e01016a1fc6106344819babe6cfa61e9ff177.png?v=1780468642\" alt=\"USS-HDBV00043 features\"\u003e\u003cimg class=\"mobile-img\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/ig_091236ea01646e01016a1fc6106344819babe6cfa61e9ff177.png?v=1780468642\" alt=\"USS-HDBV00043 features\"\u003e\n\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePremium Material Construction:\u003c\/strong\u003e Crafted from high-grade 304 stainless steel, the valve body is highly resistant to corrosion, making it suitable for handling weak acids, weak alkalis, chemical solvents, and water.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaintenance-Friendly 3-Piece Design:\u003c\/strong\u003e The innovative 3-piece body construction allows for seamless in-line maintenance. Internal components can be cleaned or replaced without disconnecting the pipes, helping reduce downtime and service costs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Pressure \u0026amp; Full-Bore Efficiency:\u003c\/strong\u003e The full-bore configuration helps minimize pressure drop and maintain efficient flow capacity in high-pressure systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSmart Automation Ready:\u003c\/strong\u003e Integrated limit switches and position feedback support PLC integration, remote control, real-time monitoring, and automated operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Torque Reliability:\u003c\/strong\u003e A compact, heavy-duty motor delivers steady 50 Nm torque for reliable full-port operation and drop-tight sealing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnhanced Safety \u0026amp; Self-Locking:\u003c\/strong\u003e The actuator features a self-locking mechanism for stable operation and a manual override port for controlled intervention during power outages or emergencies.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRugged Outdoor Durability:\u003c\/strong\u003e A powder-coated polyester aluminum housing provides resistance to corrosion and harsh weather conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdvanced Circuitry Protection:\u003c\/strong\u003e The internal PCBA is treated with a protective sealant to help prevent damage from moisture, condensation, and short circuits.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eAPPLICATIONS\u003c\/h2\u003e\n\u003cdiv class=\"image-pair\"\u003e\n\u003cimg class=\"desktop-img\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/Application_d83d7c67-93f0-46dd-bb8d-c1c7a38e6775.png?v=1779780603\" alt=\"USS-HDBV00043 applications\"\u003e\u003cimg class=\"mobile-img\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/Application_d83d7c67-93f0-46dd-bb8d-c1c7a38e6775.png?v=1779780603\" alt=\"USS-HDBV00043 applications\"\u003e\n\u003c\/div\u003e\n\u003ch2\u003eWIRING DIAGRAMS\u003c\/h2\u003e\n\u003cdiv class=\"wiring-grid\"\u003e\n\u003cdiv class=\"wiring-card\"\u003e\n\u003cdiv class=\"image-pair\"\u003e\n\u003cimg class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/DC24V-modulate-wiring.png\" alt=\"Wiring diagram A\"\u003e\u003cimg class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/DC24V-modulate-wiring.png\" alt=\"Wiring diagram A\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"control-callout\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMulti-Signal Modulating Control:\u003c\/strong\u003e Accepts 4-20 mA, 1-5V, or 0-10V DC input signals to automatically\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrecise 4–20 mA Modulating Control:\u003c\/strong\u003e Receive a standard 4–20 mA control signal and automatically position the valve for smooth, reliable flow regulation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomatic Electronic Positioning:\u003c\/strong\u003e The electronic positioner continuously compares the commanded setting with the actual valve position, then adjusts the actuator as needed to maintain the target opening.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReal-Time 4–20 mA Position Feedback:\u003c\/strong\u003e Send actual valve-position feedback to a compatible PLC, DCS, or process controller for convenient remote monitoring and control verification.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClosed-Loop Position Accuracy:\u003c\/strong\u003e A three-wire position feedback potentiometer continuously tracks valve travel, helping deliver stable, repeatable modulation across the full 0–100% stroke.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e24 VDC Power Supply:\u003c\/strong\u003e Designed for 24 VDC operation, with clearly marked positive (`+`) and negative (`−`) power terminals for straightforward installation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch2\u003eSPECIFICATIONS\u003c\/h2\u003e\n\u003cdiv class=\"spec-scroll\" role=\"region\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr style=\"border-bottom: 1px dashed #000000;\"\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003eUSS-HDBV00043\u003c\/td\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003eU.S. Solid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed #000000;\"\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eSize\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003e1\"\u003c\/td\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eWiring Type\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003eType E: Modulating Type with Integrated Servo Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed #000000;\"\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eValve Material\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003e304SS\u003c\/td\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eBall Seal\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003ePTFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed #000000;\"\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eOperating Time\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003e8 Seconds\u003c\/td\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eWorking Voltage\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003e24V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed #000000;\"\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eMax Power\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003e9.5 W\u003c\/td\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eMax Torque\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003e50 N m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed #000000;\"\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eMax Medium Pressure\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003e1.6 Mpa\u003c\/td\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003e-30°C to 180°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed #000000;\"\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eLife Expectancy\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003e30,000 to 50,000 Cycles\u003c\/td\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eBore Type\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003eFull port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed #000000;\"\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eThread Type\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003eNPT\u003c\/td\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eOperating State\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003eRemain in position\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed #000000;\"\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003e-30°C to 60°C\u003c\/td\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eEnclosure Rating\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch2\u003eWARNINGS\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Failure Behavior:\u003c\/strong\u003e This valve remains in its current position during a power outage. It does not automatically return to a preset position.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Match Required:\u003c\/strong\u003e Supply voltage must match the actuator rating exactly. Incorrect voltage may permanently damage the unit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDedicated Power Circuit:\u003c\/strong\u003e Each actuator requires its own fuse-protected power supply. Do not connect multiple actuators in parallel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDisconnect Power Before Service:\u003c\/strong\u003e Always disconnect power before wiring, maintenance, or using the manual override.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP65 Weather Resistant:\u003c\/strong\u003e Suitable for outdoor use, but additional protection is recommended for permanent outdoor installations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow Power Consumption:\u003c\/strong\u003e Power is only used during opening and closing. No power is consumed when fully open or fully closed.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProfessional Installation Recommended:\u003c\/strong\u003e Installation should be performed by qualified personnel familiar with electrical control systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003cp class=\"faq-q\"\u003e1. Can I manually operate the valve?\u003c\/p\u003e\n\u003cp class=\"faq-a\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes. The actuator features a manual override. We recommend manually cycling the valve before installation to verify smooth operation and using the adjustment screws during commissioning to fine-tune the open and closed positions.\u003c\/p\u003e\n\u003cp class=\"faq-q\"\u003e2. Can this valve be installed outdoors?\u003c\/p\u003e\n\u003cp class=\"faq-a\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes, depending on the model's IP rating. While our heavy-duty actuators are weather-resistant, we recommend using a protective cover or shelter for permanent outdoor installations to protect the unit from direct UV exposure and ice buildup.\u003c\/p\u003e\n\u003cp class=\"faq-q\"\u003e3. Is this valve suitable for high-viscosity fluids or particulates?\u003c\/p\u003e\n\u003cp class=\"faq-a\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes, subject to torque considerations. Extremely viscous media or large particulates increase resistance, so ensure the operating torque remains within the actuator's rated capacity to prevent stalling.\u003c\/p\u003e\n\u003cp class=\"faq-q\"\u003e4. Is it normal for the actuator to feel hot during operation?\u003c\/p\u003e\n\u003cp class=\"faq-a\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes. The actuator may feel warm during continuous cycling. If the housing becomes too hot to touch, check that the recommended duty cycle and ambient temperature range of -30°C to 60°C are not exceeded.\u003c\/p\u003e\n\u003cp class=\"faq-q\"\u003e5. Can I wire multiple actuators in parallel on the same circuit?\u003c\/p\u003e\n\u003cp class=\"faq-a\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e No. Each motorized actuator should use its own dedicated, fuse-protected power supply to ensure proper signal response and reduce the risk of electrical interference or damage.\u003c\/p\u003e\n\u003cp style=\"margin-top: 25px;\"\u003eDownload user manual \u003ca href=\"http:\/\/file.ussolid.com\/content\/JFHDBV\/JFHDBV-%20Electric%20Actuated%20Ball%20Valve%20instruction%20manual.pdf\" rel=\"noopener\" target=\"_blank\"\u003ehere\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"U.S. Solid","offers":[{"title":"Default Title","offer_id":50550694215935,"sku":"JFHDBV00043","price":419.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/2_883e8a45-3a30-45cc-91f7-aeea426edccd.jpg?v=1784016103"},{"product_id":"1-1-4-modulating-electric-ball-valve-24v-dc-heavy-duty-3-piece-304-ss-industrial-ball-valve-4-20ma-proportional-control-with-position-feedback","title":"1 1\/4\" Modulating Electric Ball Valve,24V DC Heavy Duty 3-Piece 304 SS Industrial Ball Valve, 4-20mA Proportional Control with Position Feedback","description":"\u003cstyle\u003e.bv-detail{font-family:Arial,sans-serif;color:#000;line-height:1.62}.bv-detail .desktop-img{display:block}.bv-detail .mobile-img{display:none}.bv-detail img{width:100%;max-width:100%;height:auto;display:block}.bv-detail h2{font-size:22px;font-weight:700;margin:25px 0 10px}.bv-detail p,.bv-detail li{font-size:16px}.bv-detail .image-pair{margin:0 0 20px}.bv-detail .wiring-grid{display:flex;flex-wrap:wrap;justify-content:center;gap:15px;margin-bottom:20px}.bv-detail .wiring-card{flex:0 1 760px;min-width:0}.bv-detail .wiring-card .image-pair{display:flex;justify-content:center;align-items:center}.bv-detail .wiring-card .image-pair img{width:auto;max-width:100%;margin:0 auto 16px!important;float:none!important}.bv-detail .wiring-card h3{text-align:center;font-size:16px;margin:0 0 10px}.bv-detail .control-callout{margin:0 0 24px;padding:18px 20px 8px;border-left:4px solid #78b72a;background:#f4f8ee}.bv-detail .control-callout h3{margin:0 0 12px;font-size:17px;color:#16220c}.bv-detail .control-callout ul{margin:0;padding-left:20px}.bv-detail .control-callout li{margin-bottom:9px}.bv-detail .spec-scroll{width:100%;overflow-x:auto;overflow-y:hidden;margin:0 0 20px;-webkit-overflow-scrolling:touch}.bv-detail .spec-scroll table{width:100%;border-collapse:collapse;background:#fff;margin:0}.bv-detail tr{border-bottom:1px dashed #000}.bv-detail th,.bv-detail td{padding:10px;text-align:left;font-size:15px;vertical-align:top}.bv-detail th{width:20%;background:#f0f0f0;font-weight:bold}.bv-detail .faq-q{font-weight:bold;margin:16px 0 5px}.bv-detail .faq-a{margin:0 0 16px;padding-left:15px}.bv-detail a{color:#0066cc;text-decoration:underline}@media(max-width:600px){.bv-detail .desktop-img{display:none!important}.bv-detail .mobile-img{display:block!important}.bv-detail h2{font-size:20px;font-weight:700}.bv-detail p,.bv-detail li{font-size:15px}.bv-detail .wiring-grid{display:block}.bv-detail .wiring-card{margin-bottom:15px}.bv-detail .control-callout{padding:15px 14px 6px}.bv-detail .control-callout h3{font-size:16px}.bv-detail .spec-scroll table{min-width:680px}.bv-detail th,.bv-detail td{padding:8px 9px;font-size:14px;white-space:normal}}\u003c\/style\u003e\n\u003cdiv class=\"bv-detail\"\u003e\n\u003cdiv class=\"image-pair\"\u003e\n\u003cimg class=\"desktop-img\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/e448011edd64412b090515ded8262a19.jpg?v=1780117738\" alt=\"USS-HDBV00044 product image\"\u003e\u003cimg class=\"mobile-img\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/e448011edd64412b090515ded8262a19.jpg?v=1780117738\" alt=\"USS-HDBV00044 product image\"\u003e\n\u003c\/div\u003e\n\u003ch2\u003eINTRODUCTION\u003c\/h2\u003e\n\u003cp\u003eThis premium flow control solution integrates a heavy-duty 3-piece stainless steel ball valve with a high-performance electric actuator. Engineered for reliability and precision, it provides a comprehensive hardware suite for automated systems, offering superior durability, seamless integration, and simplified maintenance in demanding industrial environments.\u003c\/p\u003e\n\u003ch2\u003eFEATURES\u003c\/h2\u003e\n\u003cdiv class=\"image-pair\"\u003e\n\u003cimg class=\"desktop-img\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/ig_091236ea01646e01016a1fc6106344819babe6cfa61e9ff177.png?v=1780468642\" alt=\"USS-HDBV00044 features\"\u003e\u003cimg class=\"mobile-img\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/ig_091236ea01646e01016a1fc6106344819babe6cfa61e9ff177.png?v=1780468642\" alt=\"USS-HDBV00044 features\"\u003e\n\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePremium Material Construction:\u003c\/strong\u003e Crafted from high-grade 304 stainless steel, the valve body is highly resistant to corrosion, making it suitable for handling weak acids, weak alkalis, chemical solvents, and water.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaintenance-Friendly 3-Piece Design:\u003c\/strong\u003e The innovative 3-piece body construction allows for seamless in-line maintenance. Internal components can be cleaned or replaced without disconnecting the pipes, helping reduce downtime and service costs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Pressure \u0026amp; Full-Bore Efficiency:\u003c\/strong\u003e The full-bore configuration helps minimize pressure drop and maintain efficient flow capacity in high-pressure systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSmart Automation Ready:\u003c\/strong\u003e Integrated limit switches and position feedback support PLC integration, remote control, real-time monitoring, and automated operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Torque Reliability:\u003c\/strong\u003e A compact, heavy-duty motor delivers steady 50 Nm torque for reliable full-port operation and drop-tight sealing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnhanced Safety \u0026amp; Self-Locking:\u003c\/strong\u003e The actuator features a self-locking mechanism for stable operation and a manual override port for controlled intervention during power outages or emergencies.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRugged Outdoor Durability:\u003c\/strong\u003e A powder-coated polyester aluminum housing provides resistance to corrosion and harsh weather conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdvanced Circuitry Protection:\u003c\/strong\u003e The internal PCBA is treated with a protective sealant to help prevent damage from moisture, condensation, and short circuits.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eAPPLICATIONS\u003c\/h2\u003e\n\u003cdiv class=\"image-pair\"\u003e\n\u003cimg class=\"desktop-img\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/Application_d83d7c67-93f0-46dd-bb8d-c1c7a38e6775.png?v=1779780603\" alt=\"USS-HDBV00044 applications\"\u003e\u003cimg class=\"mobile-img\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/Application_d83d7c67-93f0-46dd-bb8d-c1c7a38e6775.png?v=1779780603\" alt=\"USS-HDBV00044 applications\"\u003e\n\u003c\/div\u003e\n\u003ch2\u003eWIRING DIAGRAMS\u003c\/h2\u003e\n\u003cdiv class=\"wiring-grid\"\u003e\n\u003cdiv class=\"wiring-card\"\u003e\n\u003cdiv class=\"image-pair\"\u003e\n\u003cimg class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/DC24V-modulate-wiring.png\" alt=\"Wiring diagram A\"\u003e\u003cimg class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/DC24V-modulate-wiring.png\" alt=\"Wiring diagram A\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"control-callout\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMulti-Signal Modulating Control:\u003c\/strong\u003e Accepts 4-20 mA, 1-5V, or 0-10V DC input signals to automatically\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrecise 4–20 mA Modulating Control:\u003c\/strong\u003e Receive a standard 4–20 mA control signal and automatically position the valve for smooth, reliable flow regulation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomatic Electronic Positioning:\u003c\/strong\u003e The electronic positioner continuously compares the commanded setting with the actual valve position, then adjusts the actuator as needed to maintain the target opening.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReal-Time 4–20 mA Position Feedback:\u003c\/strong\u003e Send actual valve-position feedback to a compatible PLC, DCS, or process controller for convenient remote monitoring and control verification.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClosed-Loop Position Accuracy:\u003c\/strong\u003e A three-wire position feedback potentiometer continuously tracks valve travel, helping deliver stable, repeatable modulation across the full 0–100% stroke.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e24 VDC Power Supply:\u003c\/strong\u003e Designed for 24 VDC operation, with clearly marked positive (`+`) and negative (`−`) power terminals for straightforward installation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch2\u003eSPECIFICATIONS\u003c\/h2\u003e\n\u003cdiv class=\"spec-scroll\" role=\"region\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr style=\"border-bottom: 1px dashed #000000;\"\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003eUSS-HDBV00044\u003c\/td\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003eU.S. Solid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed #000000;\"\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eSize\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003e1 1\/4\"\u003c\/td\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eWiring Type\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003eType E: Modulating Type with Integrated Servo Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed #000000;\"\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eValve Material\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003e304SS\u003c\/td\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eBall Seal\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003ePTFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed #000000;\"\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eOperating Time\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003e8 Seconds\u003c\/td\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eWorking Voltage\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003e24V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed #000000;\"\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eMax Power\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003e9.5 W\u003c\/td\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eMax Torque\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003e50 N m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed #000000;\"\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eMax Medium Pressure\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003e1.6 Mpa\u003c\/td\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003e-30°C to 180°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed #000000;\"\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eLife Expectancy\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003e30,000 to 50,000 Cycles\u003c\/td\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eBore Type\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003eFull port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed #000000;\"\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eThread Type\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003eNPT\u003c\/td\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eOperating State\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003eRemain in position\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed #000000;\"\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003e-30°C to 60°C\u003c\/td\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eEnclosure Rating\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch2\u003eWARNINGS\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Failure Behavior:\u003c\/strong\u003e This valve remains in its current position during a power outage. It does not automatically return to a preset position.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Match Required:\u003c\/strong\u003e Supply voltage must match the actuator rating exactly. Incorrect voltage may permanently damage the unit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDedicated Power Circuit:\u003c\/strong\u003e Each actuator requires its own fuse-protected power supply. Do not connect multiple actuators in parallel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDisconnect Power Before Service:\u003c\/strong\u003e Always disconnect power before wiring, maintenance, or using the manual override.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP65 Weather Resistant:\u003c\/strong\u003e Suitable for outdoor use, but additional protection is recommended for permanent outdoor installations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow Power Consumption:\u003c\/strong\u003e Power is only used during opening and closing. No power is consumed when fully open or fully closed.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProfessional Installation Recommended:\u003c\/strong\u003e Installation should be performed by qualified personnel familiar with electrical control systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003cp class=\"faq-q\"\u003e1. Can I manually operate the valve?\u003c\/p\u003e\n\u003cp class=\"faq-a\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes. The actuator features a manual override. We recommend manually cycling the valve before installation to verify smooth operation and using the adjustment screws during commissioning to fine-tune the open and closed positions.\u003c\/p\u003e\n\u003cp class=\"faq-q\"\u003e2. Can this valve be installed outdoors?\u003c\/p\u003e\n\u003cp class=\"faq-a\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes, depending on the model's IP rating. While our heavy-duty actuators are weather-resistant, we recommend using a protective cover or shelter for permanent outdoor installations to protect the unit from direct UV exposure and ice buildup.\u003c\/p\u003e\n\u003cp class=\"faq-q\"\u003e3. Is this valve suitable for high-viscosity fluids or particulates?\u003c\/p\u003e\n\u003cp class=\"faq-a\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes, subject to torque considerations. Extremely viscous media or large particulates increase resistance, so ensure the operating torque remains within the actuator's rated capacity to prevent stalling.\u003c\/p\u003e\n\u003cp class=\"faq-q\"\u003e4. Is it normal for the actuator to feel hot during operation?\u003c\/p\u003e\n\u003cp class=\"faq-a\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes. The actuator may feel warm during continuous cycling. If the housing becomes too hot to touch, check that the recommended duty cycle and ambient temperature range of -30°C to 60°C are not exceeded.\u003c\/p\u003e\n\u003cp class=\"faq-q\"\u003e5. Can I wire multiple actuators in parallel on the same circuit?\u003c\/p\u003e\n\u003cp class=\"faq-a\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e No. Each motorized actuator should use its own dedicated, fuse-protected power supply to ensure proper signal response and reduce the risk of electrical interference or damage.\u003c\/p\u003e\n\u003cp style=\"margin-top: 25px;\"\u003eDownload user manual \u003ca href=\"http:\/\/file.ussolid.com\/content\/JFHDBV\/JFHDBV-%20Electric%20Actuated%20Ball%20Valve%20instruction%20manual.pdf\" rel=\"noopener\" target=\"_blank\"\u003ehere\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n","brand":"U.S. Solid","offers":[{"title":"Default Title","offer_id":50550694248703,"sku":"JFHDBV00044","price":429.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/1_f0ade981-585f-410f-9fa6-e4e9c11b449d.jpg?v=1783834460"},{"product_id":"1-1-2-modulating-electric-ball-valve-24v-dc-heavy-duty-3-piece-304-ss-industrial-ball-valve-4-20ma-proportional-control-with-position-feedback","title":"1 1\/2\" Modulating Electric Ball Valve,24V DC Heavy Duty 3-Piece 304 SS Industrial Ball Valve, 4-20mA Proportional Control with Position Feedback","description":"\u003cstyle\u003e.bv-detail{font-family:Arial,sans-serif;color:#000;line-height:1.62}.bv-detail .desktop-img{display:block}.bv-detail .mobile-img{display:none}.bv-detail img{width:100%;max-width:100%;height:auto;display:block}.bv-detail h2{font-size:22px;font-weight:700;margin:25px 0 10px}.bv-detail p,.bv-detail li{font-size:16px}.bv-detail .image-pair{margin:0 0 20px}.bv-detail .wiring-grid{display:flex;flex-wrap:wrap;justify-content:center;gap:15px;margin-bottom:20px}.bv-detail .wiring-card{flex:0 1 760px;min-width:0}.bv-detail .wiring-card .image-pair{display:flex;justify-content:center;align-items:center}.bv-detail .wiring-card .image-pair img{width:auto;max-width:100%;margin:0 auto 16px!important;float:none!important}.bv-detail .wiring-card h3{text-align:center;font-size:16px;margin:0 0 10px}.bv-detail .control-callout{margin:0 0 24px;padding:18px 20px 8px;border-left:4px solid #78b72a;background:#f4f8ee}.bv-detail .control-callout h3{margin:0 0 12px;font-size:17px;color:#16220c}.bv-detail .control-callout ul{margin:0;padding-left:20px}.bv-detail .control-callout li{margin-bottom:9px}.bv-detail .spec-scroll{width:100%;overflow-x:auto;overflow-y:hidden;margin:0 0 20px;-webkit-overflow-scrolling:touch}.bv-detail .spec-scroll table{width:100%;border-collapse:collapse;background:#fff;margin:0}.bv-detail tr{border-bottom:1px dashed #000}.bv-detail th,.bv-detail td{padding:10px;text-align:left;font-size:15px;vertical-align:top}.bv-detail th{width:20%;background:#f0f0f0;font-weight:bold}.bv-detail .faq-q{font-weight:bold;margin:16px 0 5px}.bv-detail .faq-a{margin:0 0 16px;padding-left:15px}.bv-detail a{color:#0066cc;text-decoration:underline}@media(max-width:600px){.bv-detail .desktop-img{display:none!important}.bv-detail .mobile-img{display:block!important}.bv-detail h2{font-size:20px;font-weight:700}.bv-detail p,.bv-detail li{font-size:15px}.bv-detail .wiring-grid{display:block}.bv-detail .wiring-card{margin-bottom:15px}.bv-detail .control-callout{padding:15px 14px 6px}.bv-detail .control-callout h3{font-size:16px}.bv-detail .spec-scroll table{min-width:680px}.bv-detail th,.bv-detail td{padding:8px 9px;font-size:14px;white-space:normal}}\u003c\/style\u003e\n\u003cdiv class=\"bv-detail\"\u003e\n\u003cdiv class=\"image-pair\"\u003e\n\u003cimg class=\"desktop-img\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/e448011edd64412b090515ded8262a19.jpg?v=1780117738\" alt=\"USS-HDBV00045 product image\"\u003e\u003cimg class=\"mobile-img\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/e448011edd64412b090515ded8262a19.jpg?v=1780117738\" alt=\"USS-HDBV00045 product image\"\u003e\n\u003c\/div\u003e\n\u003ch2\u003eINTRODUCTION\u003c\/h2\u003e\n\u003cp\u003eThis premium flow control solution integrates a heavy-duty 3-piece stainless steel ball valve with a high-performance electric actuator. Engineered for reliability and precision, it provides a comprehensive hardware suite for automated systems, offering superior durability, seamless integration, and simplified maintenance in demanding industrial environments.\u003c\/p\u003e\n\u003ch2\u003eFEATURES\u003c\/h2\u003e\n\u003cdiv class=\"image-pair\"\u003e\n\u003cimg class=\"desktop-img\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/ig_091236ea01646e01016a1fc6106344819babe6cfa61e9ff177.png?v=1780468642\" alt=\"USS-HDBV00045 features\"\u003e\u003cimg class=\"mobile-img\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/ig_091236ea01646e01016a1fc6106344819babe6cfa61e9ff177.png?v=1780468642\" alt=\"USS-HDBV00045 features\"\u003e\n\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePremium Material Construction:\u003c\/strong\u003e Crafted from high-grade 304 stainless steel, the valve body is highly resistant to corrosion, making it suitable for handling weak acids, weak alkalis, chemical solvents, and water.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaintenance-Friendly 3-Piece Design:\u003c\/strong\u003e The innovative 3-piece body construction allows for seamless in-line maintenance. Internal components can be cleaned or replaced without disconnecting the pipes, helping reduce downtime and service costs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Pressure \u0026amp; Full-Bore Efficiency:\u003c\/strong\u003e The full-bore configuration helps minimize pressure drop and maintain efficient flow capacity in high-pressure systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSmart Automation Ready:\u003c\/strong\u003e Integrated limit switches and position feedback support PLC integration, remote control, real-time monitoring, and automated operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Torque Reliability:\u003c\/strong\u003e A compact, heavy-duty motor delivers steady 50 Nm torque for reliable full-port operation and drop-tight sealing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnhanced Safety \u0026amp; Self-Locking:\u003c\/strong\u003e The actuator features a self-locking mechanism for stable operation and a manual override port for controlled intervention during power outages or emergencies.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRugged Outdoor Durability:\u003c\/strong\u003e A powder-coated polyester aluminum housing provides resistance to corrosion and harsh weather conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdvanced Circuitry Protection:\u003c\/strong\u003e The internal PCBA is treated with a protective sealant to help prevent damage from moisture, condensation, and short circuits.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eAPPLICATIONS\u003c\/h2\u003e\n\u003cdiv class=\"image-pair\"\u003e\n\u003cimg class=\"desktop-img\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/Application_d83d7c67-93f0-46dd-bb8d-c1c7a38e6775.png?v=1779780603\" alt=\"USS-HDBV00045 applications\"\u003e\u003cimg class=\"mobile-img\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/Application_d83d7c67-93f0-46dd-bb8d-c1c7a38e6775.png?v=1779780603\" alt=\"USS-HDBV00045 applications\"\u003e\n\u003c\/div\u003e\n\u003ch2\u003eWIRING DIAGRAMS\u003c\/h2\u003e\n\u003cdiv class=\"wiring-grid\"\u003e\n\u003cdiv class=\"wiring-card\"\u003e\n\u003cdiv class=\"image-pair\"\u003e\n\u003cimg class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/DC24V-modulate-wiring.png\" alt=\"Wiring diagram A\"\u003e\u003cimg class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/DC24V-modulate-wiring.png\" alt=\"Wiring diagram A\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"control-callout\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMulti-Signal Modulating Control:\u003c\/strong\u003e Accepts 4-20 mA, 1-5V, or 0-10V DC input signals to automatically\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrecise 4–20 mA Modulating Control:\u003c\/strong\u003e Receive a standard 4–20 mA control signal and automatically position the valve for smooth, reliable flow regulation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomatic Electronic Positioning:\u003c\/strong\u003e The electronic positioner continuously compares the commanded setting with the actual valve position, then adjusts the actuator as needed to maintain the target opening.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReal-Time 4–20 mA Position Feedback:\u003c\/strong\u003e Send actual valve-position feedback to a compatible PLC, DCS, or process controller for convenient remote monitoring and control verification.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClosed-Loop Position Accuracy:\u003c\/strong\u003e A three-wire position feedback potentiometer continuously tracks valve travel, helping deliver stable, repeatable modulation across the full 0–100% stroke.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e24 VDC Power Supply:\u003c\/strong\u003e Designed for 24 VDC operation, with clearly marked positive (`+`) and negative (`−`) power terminals for straightforward installation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch2\u003eSPECIFICATIONS\u003c\/h2\u003e\n\u003cdiv class=\"spec-scroll\" role=\"region\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr style=\"border-bottom: 1px dashed #000000;\"\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003eUSS-HDBV00045\u003c\/td\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003eU.S. Solid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed #000000;\"\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eSize\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003e1 1\/2\"\u003c\/td\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eWiring Type\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003eType E: Modulating Type with Integrated Servo Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed #000000;\"\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eValve Material\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003e304SS\u003c\/td\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eBall Seal\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003ePTFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed #000000;\"\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eOperating Time\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003e11 Seconds\u003c\/td\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eWorking Voltage\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003e24V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed #000000;\"\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eMax Power\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003e9 W\u003c\/td\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eMax Torque\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003e100 N m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed #000000;\"\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eMax Medium Pressure\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003e1.6 Mpa\u003c\/td\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003e-30°C to 180°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed #000000;\"\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eLife Expectancy\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003e30,000 to 50,000 Cycles\u003c\/td\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eBore Type\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003eFull port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed #000000;\"\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eThread Type\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003eNPT\u003c\/td\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eOperating State\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003eRemain in position\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed #000000;\"\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003e-30°C to 60°C\u003c\/td\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eEnclosure Rating\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch2\u003eWARNINGS\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Failure Behavior:\u003c\/strong\u003e This valve remains in its current position during a power outage. It does not automatically return to a preset position.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Match Required:\u003c\/strong\u003e Supply voltage must match the actuator rating exactly. Incorrect voltage may permanently damage the unit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDedicated Power Circuit:\u003c\/strong\u003e Each actuator requires its own fuse-protected power supply. Do not connect multiple actuators in parallel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDisconnect Power Before Service:\u003c\/strong\u003e Always disconnect power before wiring, maintenance, or using the manual override.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP65 Weather Resistant:\u003c\/strong\u003e Suitable for outdoor use, but additional protection is recommended for permanent outdoor installations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow Power Consumption:\u003c\/strong\u003e Power is only used during opening and closing. No power is consumed when fully open or fully closed.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProfessional Installation Recommended:\u003c\/strong\u003e Installation should be performed by qualified personnel familiar with electrical control systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003cp class=\"faq-q\"\u003e1. Can I manually operate the valve?\u003c\/p\u003e\n\u003cp class=\"faq-a\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes. The actuator features a manual override. We recommend manually cycling the valve before installation to verify smooth operation and using the adjustment screws during commissioning to fine-tune the open and closed positions.\u003c\/p\u003e\n\u003cp class=\"faq-q\"\u003e2. Can this valve be installed outdoors?\u003c\/p\u003e\n\u003cp class=\"faq-a\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes, depending on the model's IP rating. While our heavy-duty actuators are weather-resistant, we recommend using a protective cover or shelter for permanent outdoor installations to protect the unit from direct UV exposure and ice buildup.\u003c\/p\u003e\n\u003cp class=\"faq-q\"\u003e3. Is this valve suitable for high-viscosity fluids or particulates?\u003c\/p\u003e\n\u003cp class=\"faq-a\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes, subject to torque considerations. Extremely viscous media or large particulates increase resistance, so ensure the operating torque remains within the actuator's rated capacity to prevent stalling.\u003c\/p\u003e\n\u003cp class=\"faq-q\"\u003e4. Is it normal for the actuator to feel hot during operation?\u003c\/p\u003e\n\u003cp class=\"faq-a\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes. The actuator may feel warm during continuous cycling. If the housing becomes too hot to touch, check that the recommended duty cycle and ambient temperature range of -30°C to 60°C are not exceeded.\u003c\/p\u003e\n\u003cp class=\"faq-q\"\u003e5. Can I wire multiple actuators in parallel on the same circuit?\u003c\/p\u003e\n\u003cp class=\"faq-a\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e No. Each motorized actuator should use its own dedicated, fuse-protected power supply to ensure proper signal response and reduce the risk of electrical interference or damage.\u003c\/p\u003e\n\u003cp style=\"margin-top: 25px;\"\u003eDownload user manual \u003ca href=\"http:\/\/file.ussolid.com\/content\/JFHDBV\/JFHDBV-%20Electric%20Actuated%20Ball%20Valve%20instruction%20manual.pdf\" rel=\"noopener\" target=\"_blank\"\u003ehere\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"U.S. Solid","offers":[{"title":"Default Title","offer_id":50550694281471,"sku":"JFHDBV00045","price":509.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/1_da4a69af-61fc-41f2-bac0-2368af4e1674.jpg?v=1783836834"},{"product_id":"2-modulating-electric-ball-valve-24v-dc-heavy-duty-3-piece-304-ss-industrial-ball-valve-4-20ma-proportional-control-with-position-feedback","title":"2\" Modulating Electric Ball Valve,24V DC Heavy Duty 3-Piece 304 SS Industrial Ball Valve, 4-20mA Proportional Control with Position Feedback","description":"\u003cstyle\u003e.bv-detail{font-family:Arial,sans-serif;color:#000;line-height:1.62}.bv-detail .desktop-img{display:block}.bv-detail .mobile-img{display:none}.bv-detail img{width:100%;max-width:100%;height:auto;display:block}.bv-detail h2{font-size:22px;font-weight:700;margin:25px 0 10px}.bv-detail p,.bv-detail li{font-size:16px}.bv-detail .image-pair{margin:0 0 20px}.bv-detail .wiring-grid{display:flex;flex-wrap:wrap;justify-content:center;gap:15px;margin-bottom:20px}.bv-detail .wiring-card{flex:0 1 760px;min-width:0}.bv-detail .wiring-card .image-pair{display:flex;justify-content:center;align-items:center}.bv-detail .wiring-card .image-pair img{width:auto;max-width:100%;margin:0 auto 16px!important;float:none!important}.bv-detail .wiring-card h3{text-align:center;font-size:16px;margin:0 0 10px}.bv-detail .control-callout{margin:0 0 24px;padding:18px 20px 8px;border-left:4px solid #78b72a;background:#f4f8ee}.bv-detail .control-callout h3{margin:0 0 12px;font-size:17px;color:#16220c}.bv-detail .control-callout ul{margin:0;padding-left:20px}.bv-detail .control-callout li{margin-bottom:9px}.bv-detail .spec-scroll{width:100%;overflow-x:auto;overflow-y:hidden;margin:0 0 20px;-webkit-overflow-scrolling:touch}.bv-detail .spec-scroll table{width:100%;border-collapse:collapse;background:#fff;margin:0}.bv-detail tr{border-bottom:1px dashed #000}.bv-detail th,.bv-detail td{padding:10px;text-align:left;font-size:15px;vertical-align:top}.bv-detail th{width:20%;background:#f0f0f0;font-weight:bold}.bv-detail .faq-q{font-weight:bold;margin:16px 0 5px}.bv-detail .faq-a{margin:0 0 16px;padding-left:15px}.bv-detail a{color:#0066cc;text-decoration:underline}@media(max-width:600px){.bv-detail .desktop-img{display:none!important}.bv-detail .mobile-img{display:block!important}.bv-detail h2{font-size:20px;font-weight:700}.bv-detail p,.bv-detail li{font-size:15px}.bv-detail .wiring-grid{display:block}.bv-detail .wiring-card{margin-bottom:15px}.bv-detail .control-callout{padding:15px 14px 6px}.bv-detail .control-callout h3{font-size:16px}.bv-detail .spec-scroll table{min-width:680px}.bv-detail th,.bv-detail td{padding:8px 9px;font-size:14px;white-space:normal}}\u003c\/style\u003e\n\u003cdiv class=\"bv-detail\"\u003e\n\u003cdiv class=\"image-pair\"\u003e\n\u003cimg class=\"desktop-img\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/e448011edd64412b090515ded8262a19.jpg?v=1780117738\" alt=\"USS-HDBV00046 product image\"\u003e\u003cimg class=\"mobile-img\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/e448011edd64412b090515ded8262a19.jpg?v=1780117738\" alt=\"USS-HDBV00046 product image\"\u003e\n\u003c\/div\u003e\n\u003ch2\u003eINTRODUCTION\u003c\/h2\u003e\n\u003cp\u003eThis premium flow control solution integrates a heavy-duty 3-piece stainless steel ball valve with a high-performance electric actuator. Engineered for reliability and precision, it provides a comprehensive hardware suite for automated systems, offering superior durability, seamless integration, and simplified maintenance in demanding industrial environments.\u003c\/p\u003e\n\u003ch2\u003eFEATURES\u003c\/h2\u003e\n\u003cdiv class=\"image-pair\"\u003e\n\u003cimg class=\"desktop-img\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/ig_091236ea01646e01016a1fc6106344819babe6cfa61e9ff177.png?v=1780468642\" alt=\"USS-HDBV00046 features\"\u003e\u003cimg class=\"mobile-img\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/ig_091236ea01646e01016a1fc6106344819babe6cfa61e9ff177.png?v=1780468642\" alt=\"USS-HDBV00046 features\"\u003e\n\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePremium Material Construction:\u003c\/strong\u003e Crafted from high-grade 304 stainless steel, the valve body is highly resistant to corrosion, making it suitable for handling weak acids, weak alkalis, chemical solvents, and water.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaintenance-Friendly 3-Piece Design:\u003c\/strong\u003e The innovative 3-piece body construction allows for seamless in-line maintenance. Internal components can be cleaned or replaced without disconnecting the pipes, helping reduce downtime and service costs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Pressure \u0026amp; Full-Bore Efficiency:\u003c\/strong\u003e The full-bore configuration helps minimize pressure drop and maintain efficient flow capacity in high-pressure systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSmart Automation Ready:\u003c\/strong\u003e Integrated limit switches and position feedback support PLC integration, remote control, real-time monitoring, and automated operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Torque Reliability:\u003c\/strong\u003e A compact, heavy-duty motor delivers steady 50 Nm torque for reliable full-port operation and drop-tight sealing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnhanced Safety \u0026amp; Self-Locking:\u003c\/strong\u003e The actuator features a self-locking mechanism for stable operation and a manual override port for controlled intervention during power outages or emergencies.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRugged Outdoor Durability:\u003c\/strong\u003e A powder-coated polyester aluminum housing provides resistance to corrosion and harsh weather conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdvanced Circuitry Protection:\u003c\/strong\u003e The internal PCBA is treated with a protective sealant to help prevent damage from moisture, condensation, and short circuits.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eAPPLICATIONS\u003c\/h2\u003e\n\u003cdiv class=\"image-pair\"\u003e\n\u003cimg class=\"desktop-img\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/Application_d83d7c67-93f0-46dd-bb8d-c1c7a38e6775.png?v=1779780603\" alt=\"USS-HDBV00046 applications\"\u003e\u003cimg class=\"mobile-img\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/Application_d83d7c67-93f0-46dd-bb8d-c1c7a38e6775.png?v=1779780603\" alt=\"USS-HDBV00046 applications\"\u003e\n\u003c\/div\u003e\n\u003ch2\u003eWIRING DIAGRAMS\u003c\/h2\u003e\n\u003cdiv class=\"wiring-grid\"\u003e\n\u003cdiv class=\"wiring-card\"\u003e\n\u003cdiv class=\"image-pair\"\u003e\n\u003cimg class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/DC24V-modulate-wiring.png\" alt=\"Wiring diagram A\"\u003e\u003cimg class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHDBV\/DC24V-modulate-wiring.png\" alt=\"Wiring diagram A\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"control-callout\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMulti-Signal Modulating Control:\u003c\/strong\u003e Accepts 4-20 mA, 1-5V, or 0-10V DC input signals to automatically\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrecise 4–20 mA Modulating Control:\u003c\/strong\u003e Receive a standard 4–20 mA control signal and automatically position the valve for smooth, reliable flow regulation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomatic Electronic Positioning:\u003c\/strong\u003e The electronic positioner continuously compares the commanded setting with the actual valve position, then adjusts the actuator as needed to maintain the target opening.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReal-Time 4–20 mA Position Feedback:\u003c\/strong\u003e Send actual valve-position feedback to a compatible PLC, DCS, or process controller for convenient remote monitoring and control verification.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClosed-Loop Position Accuracy:\u003c\/strong\u003e A three-wire position feedback potentiometer continuously tracks valve travel, helping deliver stable, repeatable modulation across the full 0–100% stroke.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e24 VDC Power Supply:\u003c\/strong\u003e Designed for 24 VDC operation, with clearly marked positive (`+`) and negative (`−`) power terminals for straightforward installation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch2\u003eSPECIFICATIONS\u003c\/h2\u003e\n\u003cdiv class=\"spec-scroll\" role=\"region\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr style=\"border-bottom: 1px dashed #000000;\"\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003eUSS-HDBV00046\u003c\/td\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003eU.S. Solid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed #000000;\"\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eSize\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003e2\"\u003c\/td\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eWiring Type\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003eType E: Modulating Type with Integrated Servo Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed #000000;\"\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eValve Material\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003e304SS\u003c\/td\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eBall Seal\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003ePTFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed #000000;\"\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eOperating Time\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003e11 Seconds\u003c\/td\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eWorking Voltage\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003e24V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed #000000;\"\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eMax Power\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003e9 W\u003c\/td\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eMax Torque\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003e100 N m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed #000000;\"\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eMax Medium Pressure\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003e1.6 Mpa\u003c\/td\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003e-30°C to 180°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed #000000;\"\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eLife Expectancy\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003e30,000 to 50,000 Cycles\u003c\/td\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eBore Type\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003eFull port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed #000000;\"\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eThread Type\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003eNPT\u003c\/td\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eOperating State\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003eRemain in position\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed #000000;\"\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003e-30°C to 60°C\u003c\/td\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: #f0f0f0; font-weight: bold; text-align: center;\"\u003eEnclosure Rating\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch2\u003eWARNINGS\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Failure Behavior:\u003c\/strong\u003e This valve remains in its current position during a power outage. It does not automatically return to a preset position.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Match Required:\u003c\/strong\u003e Supply voltage must match the actuator rating exactly. Incorrect voltage may permanently damage the unit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDedicated Power Circuit:\u003c\/strong\u003e Each actuator requires its own fuse-protected power supply. Do not connect multiple actuators in parallel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDisconnect Power Before Service:\u003c\/strong\u003e Always disconnect power before wiring, maintenance, or using the manual override.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP65 Weather Resistant:\u003c\/strong\u003e Suitable for outdoor use, but additional protection is recommended for permanent outdoor installations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow Power Consumption:\u003c\/strong\u003e Power is only used during opening and closing. No power is consumed when fully open or fully closed.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProfessional Installation Recommended:\u003c\/strong\u003e Installation should be performed by qualified personnel familiar with electrical control systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003cp class=\"faq-q\"\u003e1. Can I manually operate the valve?\u003c\/p\u003e\n\u003cp class=\"faq-a\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes. The actuator features a manual override. We recommend manually cycling the valve before installation to verify smooth operation and using the adjustment screws during commissioning to fine-tune the open and closed positions.\u003c\/p\u003e\n\u003cp class=\"faq-q\"\u003e2. Can this valve be installed outdoors?\u003c\/p\u003e\n\u003cp class=\"faq-a\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes, depending on the model's IP rating. While our heavy-duty actuators are weather-resistant, we recommend using a protective cover or shelter for permanent outdoor installations to protect the unit from direct UV exposure and ice buildup.\u003c\/p\u003e\n\u003cp class=\"faq-q\"\u003e3. Is this valve suitable for high-viscosity fluids or particulates?\u003c\/p\u003e\n\u003cp class=\"faq-a\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes, subject to torque considerations. Extremely viscous media or large particulates increase resistance, so ensure the operating torque remains within the actuator's rated capacity to prevent stalling.\u003c\/p\u003e\n\u003cp class=\"faq-q\"\u003e4. Is it normal for the actuator to feel hot during operation?\u003c\/p\u003e\n\u003cp class=\"faq-a\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes. The actuator may feel warm during continuous cycling. If the housing becomes too hot to touch, check that the recommended duty cycle and ambient temperature range of -30°C to 60°C are not exceeded.\u003c\/p\u003e\n\u003cp class=\"faq-q\"\u003e5. Can I wire multiple actuators in parallel on the same circuit?\u003c\/p\u003e\n\u003cp class=\"faq-a\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e No. Each motorized actuator should use its own dedicated, fuse-protected power supply to ensure proper signal response and reduce the risk of electrical interference or damage.\u003c\/p\u003e\n\u003cp style=\"margin-top: 25px;\"\u003eDownload user manual \u003ca href=\"http:\/\/file.ussolid.com\/content\/JFHDBV\/JFHDBV-%20Electric%20Actuated%20Ball%20Valve%20instruction%20manual.pdf\" rel=\"noopener\" target=\"_blank\"\u003ehere\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"U.S. Solid","offers":[{"title":"Default Title","offer_id":50550694314239,"sku":"JFHDBV00046","price":559.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/2_83fdba60-e579-428d-96e0-95663220614e.jpg?v=1784017419"}],"url":"https:\/\/ussolid.com\/collections\/electric-actuated-ball-valve.oembed?page=2","provider":"U.S. Solid","version":"1.0","type":"link"}