{"title":"Moisture Analyzer","description":"\u003cp\u003eA moisture analyzer, also referred to as a moisture balance, serves as a sophisticated instrument utilized in the precise determination of the moisture content present within a given sample.\u003c\/p\u003e\n\u003cp\u003eFunctioning on the fundamental principle of loss on drying, the moisture analyzer commences by gauging the initial weight of the sample. Subsequently, the sample undergoes rapid heating courtesy of the halogen lamp embedded within the drying unit, triggering the moisture to undergo a phase change into vapor. Throughout the drying process, the instrument continuously monitors and records the evolving weight of the sample, accurately displaying the gradual loss of moisture in real-time. Upon the culmination of the drying cycle, the moisture analyzer computes the moisture content or dry solids content of the sample by meticulously analyzing the weight differential observed pre- and post-drying.\u003c\/p\u003e\n\u003cp\u003eU.S. Solid's range of Moisture Analyzers boast exceptional weight readability spanning from 0.01 g to 0.0001 g, coupled with moisture readability ranging from 0.1% to 0.001%. These products are segmented into three distinctive series - mainstream, economical, and high-end - each tailored to cater to diverse precision requirements and operational functionalities. Regardless of your intended usage scenarios, U.S. Solid's comprehensive suite of moisture analyzers ensures the availability of a solution that seamlessly aligns with and addresses your unique application demands.\u003c\/p\u003e","products":[{"product_id":"moisture-analyzer-110g-x-5mg-0-1-readability-halogen-moisture-balance-by-u-s-solid-html","title":"Moisture Analyzer-110g x 5mg, 0.1% Readability Halogen Moisture Balance by U.S. Solid","description":"\u003cbody\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003cmeta content=\"width=device-width, initial-scale=1.0\" name=\"viewport\"\u003e\n\u003ctitle\u003eResponsive Page with Multiple Modules\u003c\/title\u003e\n\u003cstyle\u003e\n        \n        .desktop-img {\n            display: block;\n        }\n        .mobile-img {\n            display: none;\n        } \n\n        \n        .section-title {\n            font-size: 22px;\n            line-height: 22px;\n            font-weight: bold;\n            margin: 15px 0 5px; \n            font-family: Arial;\n        }\n        \n        .section-title2 {\n            font-size: 22px;\n            line-height: 22px;\n            font-weight: bold;\n            margin: 15px 0 3px; \n            font-family: Arial;\n        }\n        \n        .section-title3 {\n            font-size: 22px;\n            line-height: 22px;\n            font-weight: bold;\n            margin: 15px 0 10px; \n            font-family: Arial;\n        }\n\n        \n        .section-description {\n            font-size: 16px;\n            line-height: 26px;\n            margin-top: 0px;\n            margin-bottom: 5px; \n            font-family: Arial;\n        }\n        \n        .faq {\n            font-size: 16px; \n            margin: 0; \n            line-height: 26px; \n            background-color: #f2f2f2; \n            padding: 5px;\n        }\n        \n        .section-description2 {\n            font-size: 16px;\n            line-height: 26px;\n            margin: 0px; \n            font-family: Arial;\n        }\n        \n.parameters-table-wrapper {\n    overflow-x: auto; \n    -webkit-overflow-scrolling: touch; \n    margin-top: 0px;\n}\n\n\n.parameters-table {\n    width: 100%;\n    min-width: 1000px; \n    border-collapse: collapse;\n    margin-top: 0px;\n}\n\n.parameters-table th, .parameters-table td {\n    border-top: 1.2px solid #a6a6a6;  \n    border-bottom: 1.2px solid #a6a6a6;  \n    border-left: none;  \n    border-right: none;  \n    padding: 5px 2px;\n    text-align: left;\n    font-size: 16px;\n    line-height: 16px;\n}\n\n.parameters-table th {\n    background-color: #f2f2f2;\n    color: #2c2c2c;\n    font-weight: bold;\n}\n\n\n.parameters-table .bg-gray {\n    background-color: #f2f2f2;  \n}\n\n\n.options-table-wrapper {\n    overflow-x: auto; \n    -webkit-overflow-scrolling: touch; \n    margin-top: 0px;\n}\n\n.options-table {\n    width: 100%;\n    min-width: 1000px; \n    border-collapse: collapse;\n    margin-top: 0px;\n    box-shadow: 0 6px 25px rgba(0, 0, 0, 0.1); \n}\n\n.options-table th, .options-table td {\n    border: 2px solid #000;  \n    padding: 5px 2px;  \n    text-align: center;\n    font-size: 16px;\n    line-height: 16px;\n}\n\n.options-table th {\n    background-color: #f2f2f2;\n    color: #2c2c2c;\n    font-weight: bold;\n}\n\n\n.parameters-table2 {\n    width: 100%;\n    min-width: 1000px; \n    border-collapse: collapse;\n    margin-top: 0px;\n}\n\n.parameters-table2 th, .parameters-table2 td {\n    border-top: 1.2px solid #a6a6a6;  \n    border-bottom: 1.2px solid #a6a6a6;  \n    border-left: none;  \n    border-right: none;  \n    padding: 5px 2px;\n    text-align: center;\n    font-size: 16px;\n    line-height: 16px;\n}\n\n.parameters-table2 th {\n    background-color: #f2f2f2;\n    color: #2c2c2c;\n    font-weight: bold;\n}\n\n\n.parameters-table2 .bg-gray {\n    background-color: #f2f2f2;  \n}\n\n\n.options-table-wrapper2 {\n    overflow-x: auto; \n    -webkit-overflow-scrolling: touch; \n    margin-top: 0px;\n}\n\n\n@media (max-width: 768px) {\n    .parameters-table th, .parameters-table td {\n        font-size: 14px; \n        padding: 8px 4px; \n    }\n\n    \n    .options-table th, .options-table td {\n        font-size: 14px; \n        padding: 8px 4px;\n    }\n\n    .parameters-table-wrapper {\n        overflow-x: auto;\n    }\n    .parameters-table2 th, .parameters-table2 td {\n        font-size: 14px; \n        padding: 8px 4px; \n    }\n    .parameters-table-wrapper2 {\n        overflow-x: auto;\n    }\n    .desktop-img {\n                display: none; \n            }\n            .mobile-img {\n                display: block; \n            }\n    \n}\n\n@media (max-width: 480px) {\n    .parameters-table th, .parameters-table td {\n        font-size: 12px; \n        padding: 6px 3px; \n    }\n\n    \n    .options-table th, .options-table td {\n        font-size: 12px; \n    }\n\n    .parameters-table-wrapper {\n        overflow-x: auto;\n    }\n    .parameters-table2 th, .parameters-table2 td {\n        font-size: 12px; \n        padding: 6px 3px; \n    }\n    .parameters-table-wrapper2 {\n        overflow-x: auto;\n    }\n    .desktop-img {\n                display: none; \n            }\n            .mobile-img {\n                display: block; \n            }\n    \n}\n    \u003c\/style\u003e\n\u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHMA\/jfhma01-background.png\"\u003e\n\u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHMA\/USS-HMA01.png\"\u003e\n\u003cdiv\u003e\n\u003ch2 class=\"section-title\"\u003eIntroduction\u003c\/h2\u003e\n\u003cp class=\"section-description\"\u003e\n            The U.S. Solid USS-HMA01 Moisture Analyzer provides a high level of operating convenience and response sensitivity to facilitate determination of the moisture content of your samples.\u003cbr\u003e\n            It comes with smart functionalities that allows you to preset and store measuring methods, so you can access the options with ease. The device features a 450W halogen lamp and a premium transducer that delivers fast and accurate results even on low-moisture samples. Compact, practical, and easy to use, this moisture balance is a better choice for every lab.\u003cbr\u003eMoisture analyzers work according to the thermogravimetric principle. Moisture is determined by the direct weight lost by the sample due to heating from an intense halogen light.\n        \u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch2 class=\"section-title2\"\u003eApplications\u003c\/h2\u003e\n\u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHMA\/jfhma01-3%281%29.jpg\"\u003e\n\u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHMA\/jfhma-background.jpg\"\u003e\n\u003cdiv\u003e\n\u003ch2 class=\"section-title\"\u003eFeatures\u003c\/h2\u003e\n\u003cul class=\"section-description2\"\u003e\n\u003cli\u003eReadability: 0.005g (5mg)\u003c\/li\u003e\n\u003cli\u003eMoisture readability: 0.1%\u003c\/li\u003e\n\u003cli\u003eManual calibration\u003c\/li\u003e\n\u003cli\u003eWeighing sensor: High-end strain gauge\u003c\/li\u003e\n\u003cli\u003e3 drying modes (standard\/fast\/soft)\u003c\/li\u003e\n\u003cli\u003e3 ending modes (automatic\/manual\/timing)\u003c\/li\u003e\n\u003cli\u003e15 groups of methods can be preset and stored\u003c\/li\u003e\n\u003cli\u003e3 kinds of result display (moisture percentage\/dry weight\/dry-weight percentage)\u003c\/li\u003e\n\u003cli\u003e50 \u003ca href=\"https:\/\/ussolid.com\/products\/aluminum-sample-pan-pack-of-50-for-u-s-solid-moisture-analyzers-html\"\u003esample pans\u003c\/a\u003e included\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch2 class=\"section-title\"\u003eMore Details\u003c\/h2\u003e\n\u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHMA\/jfhma01.jpg\"\u003e\n\u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHMA\/jfhma01-p-2.jpg\"\u003e\n\u003ch2 class=\"section-title\"\u003eUser Manual\u003c\/h2\u003e\n\u003cp class=\"section-description\"\u003e\n            For detailed information on calibration, installation, setup, and usage, please refer to the \u003ca href=\"https:\/\/file.ussolid.com\/content\/JFHMA\/USS-HMA01%20Instruction%20Manual.pdf\" target=\"_blank\"\u003euser manual\u003c\/a\u003e and watch the \u003ca href=\"https:\/\/www.youtube.com\/watch?reload=9\u0026amp;v=X3YmIjz3MRA\u0026amp;list=TLGGwmkqarTR3YoxOTEyMjAyNA\u0026amp;t=58s\" target=\"_blank\"\u003etutorial video\u003c\/a\u003e.\n    \u003c\/p\u003e\n\u003ch2 class=\"section-title3\"\u003eTechnical Data\u003c\/h2\u003e\n\u003cdiv class=\"parameters-table-wrapper\"\u003e\n\u003ctable class=\"parameters-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSS-HMA01\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eCalibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eCapacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110 g\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eDisplays of results\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e[%m]\/ [%]\/ [g]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eWeight Readability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.005 g\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eCalibration Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eMoisture Readability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1%\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eStabilization Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 3s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eHeating Element\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e450W Halogen Lamp\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003ePan size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eΦ90mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e104℉-390.2℉ (40℃-199℃)\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRS-232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eTime setting range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 - 99 min\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003ePower\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110V 60Hz AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eDrying mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard\/ Fast\/ Soft\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8.3*13.1*6.9 inches(210*340*180 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eEnding mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAuto\/ Timing\/ Manual\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.45 lbs (4.74 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch2 class=\"section-title3\"\u003eCE Certified Quality \u0026amp; Safety\u003c\/h2\u003e\n\u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/CE\/CE.jpg\"\u003e\n\u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/CE\/CE.jpg\"\u003e\n\u003ch2 class=\"section-title3\"\u003eAll Options\u003c\/h2\u003e\n\u003cdiv class=\"parameters-table-wrapper2\"\u003e\n\u003ctable class=\"parameters-table2\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eUSS-HMA01\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/ussolid.com\/products\/moisture-analyzer-110g-x-1mg-0-01-readability-halogen-moisture-balance-by-u-s-solid-html\" target=\"_blank\"\u003e\u003cstrong\u003eUSS-HMA02\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/ussolid.com\/products\/moisture-analyzer-110g-x-1mg-0-01-readability-touch-screen-halogen-moisture-balance-by-u-s-solid-html\" target=\"_blank\"\u003e\u003cstrong\u003eUSS-HMA03\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/ussolid.com\/products\/moisture-analyzer-0-001-g-0-01-readability-moisture-balance-7-inch-touch-screen-html\" target=\"_blank\"\u003e\u003cstrong\u003eUSS-HMA11\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/ussolid.com\/products\/moisture-analyzer-0-001-g-0-01-readability-moisture-balance-7-inch-touch-screen-automatic-door-html\" target=\"_blank\"\u003e\u003cstrong\u003eUSS-HMA12\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/ussolid.com\/products\/moisture-analyzer-0-0001-g-0-001-readability-moisture-balance-7-inch-touch-screen-automatic-door-html\" target=\"_blank\"\u003e\u003cstrong\u003eUSS-HMA13\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/ussolid.com\/products\/moisture-analyzer-0-0001-g-0-001-readability-moisture-balance-7-inch-touch-screen-internal-calibration-and-automatic-door-html\" target=\"_blank\"\u003e\u003cstrong\u003eUSS-HMA14\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/ussolid.com\/products\/moisture-analyzer-0-01-g-0-1-readability-moisture-balance-5-inch-touch-screen-110-g-capacity-html\" target=\"_blank\"\u003e\u003cstrong\u003eUSS-HMA21\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/ussolid.com\/products\/moisture-analyzer-0-005-g-0-05-readability-moisture-balance-5-inch-touch-screen-110-g-capacity-html\" target=\"_blank\"\u003e\u003cstrong\u003eUSS-HMA22\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/ussolid.com\/products\/moisture-analyzer-0-001-g-0-01-readability-moisture-balance-5-inch-touch-screen-110-g-capacity-html\" target=\"_blank\"\u003e\u003cstrong\u003eUSS-HMA23\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003ePositioning\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eMainstream\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eHigh-end\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eEconomical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eWeight Readability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.005 g\u003c\/td\u003e\n\u003ctd\u003e0.001 g\u003c\/td\u003e\n\u003ctd\u003e0.001 g\u003c\/td\u003e\n\u003ctd\u003e0.001 g\u003c\/td\u003e\n\u003ctd\u003e0.001 g\u003c\/td\u003e\n\u003ctd\u003e0.0001 g\u003c\/td\u003e\n\u003ctd\u003e0.0001 g\u003c\/td\u003e\n\u003ctd\u003e0.01 g\u003c\/td\u003e\n\u003ctd\u003e0.005 g\u003c\/td\u003e\n\u003ctd\u003e0.001 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eMoisture Readability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 %\u003c\/td\u003e\n\u003ctd\u003e0.01 %\u003c\/td\u003e\n\u003ctd\u003e0.01 %\u003c\/td\u003e\n\u003ctd\u003e0.01 %\u003c\/td\u003e\n\u003ctd\u003e0.01 %\u003c\/td\u003e\n\u003ctd\u003e0.001 %\u003c\/td\u003e\n\u003ctd\u003e0.001 %\u003c\/td\u003e\n\u003ctd\u003e0.1 %\u003c\/td\u003e\n\u003ctd\u003e0.05 %\u003c\/td\u003e\n\u003ctd\u003e0.01 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eWeighing Sensor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eHigh-end strain gauge\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eHigh-end strain gauge\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eElectromagnetic force\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eStrain gauge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eControl Panel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePush Button\u003c\/td\u003e\n\u003ctd\u003ePush Button\u003c\/td\u003e\n\u003ctd\u003e5\" Touch Screen\u003c\/td\u003e\n\u003ctd\u003e7\" Touch Screen\u003c\/td\u003e\n\u003ctd\u003e7\" Touch Screen\u003c\/td\u003e\n\u003ctd\u003e7\" Touch Screen\u003c\/td\u003e\n\u003ctd\u003e7\" Touch Screen\u003c\/td\u003e\n\u003ctd\u003e5\" Touch Screen\u003c\/td\u003e\n\u003ctd\u003e5\" Touch Screen\u003c\/td\u003e\n\u003ctd\u003e5\" Touch Screen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eCalibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eAuto\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eHeater Cover\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eAuto\u003c\/td\u003e\n\u003ctd\u003eAuto\u003c\/td\u003e\n\u003ctd\u003eAuto\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eData Storage Group\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003e200\u003c\/td\u003e\n\u003ctd\u003e200\u003c\/td\u003e\n\u003ctd\u003e200\u003c\/td\u003e\n\u003ctd\u003e200\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e40℃ - 199℃\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e40 ℃ - 200℃\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e40 ℃ - 160℃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eDrying mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eStandard, Fast, Soft\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eStandard, Fast, Soft, Step\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eStandard, Fast, Soft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eEnding mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"10\"\u003eAuto, Timing, Manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003ePan size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eΦ90 mm\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eΦ100 mm\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eΦ100 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"10\"\u003eRS-232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/body\u003e","brand":"U.S. Solid","offers":[{"title":"Default Title","offer_id":46324229964031,"sku":"JFHMA00001","price":754.87,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/public__03019.1650787817.1280.1280.jpg?v=1731291366"},{"product_id":"moisture-analyzer-110g-x-1mg-0-01-readability-halogen-moisture-balance-by-u-s-solid-html","title":"Moisture Analyzer-110g x 1mg, 0.01% Readability Halogen Moisture Balance by U.S. Solid","description":"\u003cbody\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003cmeta content=\"width=device-width, initial-scale=1.0\" name=\"viewport\"\u003e\n\u003ctitle\u003eResponsive Page with Multiple Modules\u003c\/title\u003e\n\u003cstyle\u003e\n        \n        .desktop-img {\n            display: block;\n        }\n        .mobile-img {\n            display: none;\n        } \n\n        \n        .section-title {\n            font-size: 22px;\n            line-height: 22px;\n            font-weight: bold;\n            margin: 15px 0 5px; \n            font-family: Arial;\n        }\n        \n        .section-title2 {\n            font-size: 22px;\n            line-height: 22px;\n            font-weight: bold;\n            margin: 15px 0 3px; \n            font-family: Arial;\n        }\n        \n        .section-title3 {\n            font-size: 22px;\n            line-height: 22px;\n            font-weight: bold;\n            margin: 15px 0 10px; \n            font-family: Arial;\n        }\n\n        \n        .section-description {\n            font-size: 16px;\n            line-height: 26px;\n            margin-top: 0px;\n            margin-bottom: 5px; \n            font-family: Arial;\n        }\n        \n        .faq {\n            font-size: 16px; \n            margin: 0; \n            line-height: 26px; \n            background-color: #f2f2f2; \n            padding: 5px;\n        }\n        \n        .section-description2 {\n            font-size: 16px;\n            line-height: 26px;\n            margin: 0px; \n            font-family: Arial;\n        }\n        \n.parameters-table-wrapper {\n    overflow-x: auto; \n    -webkit-overflow-scrolling: touch; \n    margin-top: 0px;\n}\n\n\n.parameters-table {\n    width: 100%;\n    min-width: 1000px; \n    border-collapse: collapse;\n    margin-top: 0px;\n}\n\n.parameters-table th, .parameters-table td {\n    border-top: 1.2px solid #a6a6a6;  \n    border-bottom: 1.2px solid #a6a6a6;  \n    border-left: none;  \n    border-right: none;  \n    padding: 5px 2px;\n    text-align: left;\n    font-size: 16px;\n    line-height: 16px;\n}\n\n.parameters-table th {\n    background-color: #f2f2f2;\n    color: #2c2c2c;\n    font-weight: bold;\n}\n\n\n.parameters-table .bg-gray {\n    background-color: #f2f2f2;  \n}\n\n\n.options-table-wrapper {\n    overflow-x: auto; \n    -webkit-overflow-scrolling: touch; \n    margin-top: 0px;\n}\n\n.options-table {\n    width: 100%;\n    min-width: 1000px; \n    border-collapse: collapse;\n    margin-top: 0px;\n    box-shadow: 0 6px 25px rgba(0, 0, 0, 0.1); \n}\n\n.options-table th, .options-table td {\n    border: 2px solid #000;  \n    padding: 5px 2px;  \n    text-align: center;\n    font-size: 16px;\n    line-height: 16px;\n}\n\n.options-table th {\n    background-color: #f2f2f2;\n    color: #2c2c2c;\n    font-weight: bold;\n}\n\n\n.parameters-table2 {\n    width: 100%;\n    min-width: 1000px; \n    border-collapse: collapse;\n    margin-top: 0px;\n}\n\n.parameters-table2 th, .parameters-table2 td {\n    border-top: 1.2px solid #a6a6a6;  \n    border-bottom: 1.2px solid #a6a6a6;  \n    border-left: none;  \n    border-right: none;  \n    padding: 5px 2px;\n    text-align: center;\n    font-size: 16px;\n    line-height: 16px;\n}\n\n.parameters-table2 th {\n    background-color: #f2f2f2;\n    color: #2c2c2c;\n    font-weight: bold;\n}\n\n\n.parameters-table2 .bg-gray {\n    background-color: #f2f2f2;  \n}\n\n\n.options-table-wrapper2 {\n    overflow-x: auto; \n    -webkit-overflow-scrolling: touch; \n    margin-top: 0px;\n}\n\n\n@media (max-width: 768px) {\n    .parameters-table th, .parameters-table td {\n        font-size: 14px; \n        padding: 8px 4px; \n    }\n\n    \n    .options-table th, .options-table td {\n        font-size: 14px; \n        padding: 8px 4px;\n    }\n\n    .parameters-table-wrapper {\n        overflow-x: auto;\n    }\n    .parameters-table2 th, .parameters-table2 td {\n        font-size: 14px; \n        padding: 8px 4px; \n    }\n    .parameters-table-wrapper2 {\n        overflow-x: auto;\n    }\n    .desktop-img {\n                display: none; \n            }\n            .mobile-img {\n                display: block; \n            }\n    \n}\n\n@media (max-width: 480px) {\n    .parameters-table th, .parameters-table td {\n        font-size: 12px; \n        padding: 6px 3px; \n    }\n\n    \n    .options-table th, .options-table td {\n        font-size: 12px; \n    }\n\n    .parameters-table-wrapper {\n        overflow-x: auto;\n    }\n    .parameters-table2 th, .parameters-table2 td {\n        font-size: 12px; \n        padding: 6px 3px; \n    }\n    .parameters-table-wrapper2 {\n        overflow-x: auto;\n    }\n    .desktop-img {\n                display: none; \n            }\n            .mobile-img {\n                display: block; \n            }\n    \n}\n    \u003c\/style\u003e\n\u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHMA\/jfhma02-background.png\"\u003e\n\u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHMA\/USS-HMA02.png\"\u003e\n\u003cdiv\u003e\n\u003ch2 class=\"section-title\"\u003eIntroduction\u003c\/h2\u003e\n\u003cp class=\"section-description\"\u003e\n            The U.S. Solid USS-HMA02 Moisture Analyzer provides a high level of operating convenience and response sensitivity to facilitate determination of the moisture content of your samples.\u003cbr\u003e\n            It comes with smart functionalities that allows you to preset and store measuring methods, so you can access the options with ease. The device features a 450W halogen lamp and a premium transducer that delivers fast and accurate results even on low-moisture samples. Compact, practical, and easy to use, this moisture balance is a better choice for every lab.\u003cbr\u003eMoisture analyzers work according to the thermogravimetric principle. Moisture is determined by the direct weight lost by the sample due to heating from an intense halogen light.\n        \u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch2 class=\"section-title2\"\u003eApplications\u003c\/h2\u003e\n\u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHMA\/jfhma01-3%281%29.jpg\"\u003e\n\u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHMA\/jfhma-background.jpg\"\u003e\n\u003cdiv\u003e\n\u003ch2 class=\"section-title\"\u003eFeatures\u003c\/h2\u003e\n\u003cul class=\"section-description2\"\u003e\n\u003cli\u003eReadability: 0.001g (1mg)\u003c\/li\u003e\n\u003cli\u003eMoisture readability: 0.01%\u003c\/li\u003e\n\u003cli\u003eManual calibration\u003c\/li\u003e\n\u003cli\u003eWeighing sensor: High-end strain gauge\u003c\/li\u003e\n\u003cli\u003e3 drying modes (standard\/fast\/soft)\u003c\/li\u003e\n\u003cli\u003e3 ending modes (automatic\/manual\/timing)\u003c\/li\u003e\n\u003cli\u003e15 groups of methods can be preset and stored\u003c\/li\u003e\n\u003cli\u003e3 kinds of result display (moisture percentage\/dry weight\/dry-weight percentage)\u003c\/li\u003e\n\u003cli\u003e50 \u003ca href=\"https:\/\/ussolid.com\/products\/aluminum-sample-pan-pack-of-50-for-u-s-solid-moisture-analyzers-html\"\u003esample pans\u003c\/a\u003e included\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch2 class=\"section-title\"\u003eMore Details\u003c\/h2\u003e\n\u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHMA\/jfhma02.jpg\"\u003e\n\u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHMA\/jfhma02-p-2.png\"\u003e\n\u003ch2 class=\"section-title\"\u003eUser Manual\u003c\/h2\u003e\n\u003cp class=\"section-description\"\u003e\n            For detailed information on calibration, installation, setup, and usage, please refer to the \u003ca href=\"https:\/\/file.ussolid.com\/content\/JFHMA\/USS-HMA02%20Instruction%20Manual.pdf\" target=\"_blank\"\u003euser manual\u003c\/a\u003e and watch the \u003ca href=\"https:\/\/www.youtube.com\/watch?v=uKtVu_ASZ4Q\u0026amp;feature=youtu.be\" target=\"_blank\"\u003etutorial video\u003c\/a\u003e.\n    \u003c\/p\u003e\n\u003ch2 class=\"section-title3\"\u003eTechnical Data\u003c\/h2\u003e\n\u003cdiv class=\"parameters-table-wrapper\"\u003e\n\u003ctable class=\"parameters-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSS-HMA02\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eCalibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eCapacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110 g\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eDisplays of results\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e[%m]\/ [%]\/ [g]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eWeight Readability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.001 g\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eCalibration Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eMoisture Readability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01%\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eStabilization Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 3s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eHeating Element\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e450W Halogen Lamp\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003ePan size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eΦ90mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e104℉-390.2℉ (40℃-199℃)\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRS-232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eTime setting range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 - 99 min\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003ePower\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110V 60Hz AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eDrying mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard\/ Fast\/ Soft\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8.3*13.1*6.9 inches(210*340*180 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eEnding mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAuto\/ Timing\/ Manual\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.45 lbs (4.74 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ch2 class=\"section-title\"\u003eTroubleshooting\u003c\/h2\u003e\n\u003cp class=\"faq\"\u003e\u003cb\u003eProblem 1: Display remains off after switching on.\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003ePossible causes: Power cord is not connected\/ Power line fuse blown\/ Power supply interrupted\/ Instrument faulty\u003c\/p\u003e\n\u003cp class=\"faq\"\u003e\u003cb\u003eProblem 2: Display does not change when loading samples.\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003ePossible causes: The sample pan\/pan holder is not installed correctly.\u003c\/p\u003e\n\u003cp class=\"faq\"\u003e\u003cb\u003eProblem 3: Weight display is constantly changing or unstable.\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003ePossible causes: The sample pan is in contact with the draft shield or heating chamber\/ Air movement\/ Test bench vibration\/ Electromagnetic field interference\u003c\/p\u003e\n\u003cp class=\"faq\"\u003e\u003cb\u003eProblem 4: Drying does not start.\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003ePossible causes: Heating chamber open\/ Power cord is not connected\/ Power line fuse blown\u003c\/p\u003e\n\u003cp class=\"faq\"\u003e\u003cb\u003eProblem 5：Measurement takes too long.\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003ePossible causes: Incorrect ending mode selected\u003c\/p\u003e\n\u003cp class=\"faq\"\u003e\u003cb\u003eProblem 6: Measurements are not repeatable.\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003ePossible causes: The samples are not homogeneous.\/ Drying time is too short.\/ The temp selected is too high and the sample has been oxidized.\/ The temperature sensor is contaminated or defective.\/ The sample is not completely dry.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch2 class=\"section-title3\"\u003eCE Certified Quality \u0026amp; Safety\u003c\/h2\u003e\n\u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/CE\/CE.jpg\"\u003e\n\u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/CE\/CE.jpg\"\u003e\n\u003ch2 class=\"section-title3\"\u003eAll Options\u003c\/h2\u003e\n\u003cdiv class=\"parameters-table-wrapper2\"\u003e\n\u003ctable class=\"parameters-table2\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/ussolid.com\/products\/moisture-analyzer-110g-x-5mg-0-1-readability-halogen-moisture-balance-by-u-s-solid-html\" target=\"_blank\"\u003e\u003cstrong\u003eUSS-HMA01\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eUSS-HMA02\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/ussolid.com\/products\/moisture-analyzer-110g-x-1mg-0-01-readability-touch-screen-halogen-moisture-balance-by-u-s-solid-html\" target=\"_blank\"\u003e\u003cstrong\u003eUSS-HMA03\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/ussolid.com\/products\/moisture-analyzer-0-001-g-0-01-readability-moisture-balance-7-inch-touch-screen-html\" target=\"_blank\"\u003e\u003cstrong\u003eUSS-HMA11\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/ussolid.com\/products\/moisture-analyzer-0-001-g-0-01-readability-moisture-balance-7-inch-touch-screen-automatic-door-html\" target=\"_blank\"\u003e\u003cstrong\u003eUSS-HMA12\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/ussolid.com\/products\/moisture-analyzer-0-0001-g-0-001-readability-moisture-balance-7-inch-touch-screen-automatic-door-html\" target=\"_blank\"\u003e\u003cstrong\u003eUSS-HMA13\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/ussolid.com\/products\/moisture-analyzer-0-0001-g-0-001-readability-moisture-balance-7-inch-touch-screen-internal-calibration-and-automatic-door-html\" target=\"_blank\"\u003e\u003cstrong\u003eUSS-HMA14\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/ussolid.com\/products\/moisture-analyzer-0-01-g-0-1-readability-moisture-balance-5-inch-touch-screen-110-g-capacity-html\" target=\"_blank\"\u003e\u003cstrong\u003eUSS-HMA21\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/ussolid.com\/products\/moisture-analyzer-0-005-g-0-05-readability-moisture-balance-5-inch-touch-screen-110-g-capacity-html\" target=\"_blank\"\u003e\u003cstrong\u003eUSS-HMA22\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/ussolid.com\/products\/moisture-analyzer-0-001-g-0-01-readability-moisture-balance-5-inch-touch-screen-110-g-capacity-html\" target=\"_blank\"\u003e\u003cstrong\u003eUSS-HMA23\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003ePositioning\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eMainstream\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eHigh-end\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eEconomical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eWeight Readability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.005 g\u003c\/td\u003e\n\u003ctd\u003e0.001 g\u003c\/td\u003e\n\u003ctd\u003e0.001 g\u003c\/td\u003e\n\u003ctd\u003e0.001 g\u003c\/td\u003e\n\u003ctd\u003e0.001 g\u003c\/td\u003e\n\u003ctd\u003e0.0001 g\u003c\/td\u003e\n\u003ctd\u003e0.0001 g\u003c\/td\u003e\n\u003ctd\u003e0.01 g\u003c\/td\u003e\n\u003ctd\u003e0.005 g\u003c\/td\u003e\n\u003ctd\u003e0.001 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eMoisture Readability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 %\u003c\/td\u003e\n\u003ctd\u003e0.01 %\u003c\/td\u003e\n\u003ctd\u003e0.01 %\u003c\/td\u003e\n\u003ctd\u003e0.01 %\u003c\/td\u003e\n\u003ctd\u003e0.01 %\u003c\/td\u003e\n\u003ctd\u003e0.001 %\u003c\/td\u003e\n\u003ctd\u003e0.001 %\u003c\/td\u003e\n\u003ctd\u003e0.1 %\u003c\/td\u003e\n\u003ctd\u003e0.05 %\u003c\/td\u003e\n\u003ctd\u003e0.01 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eWeighing Sensor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eHigh-end strain gauge\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eHigh-end strain gauge\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eElectromagnetic force\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eStrain gauge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eControl Panel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePush Button\u003c\/td\u003e\n\u003ctd\u003ePush Button\u003c\/td\u003e\n\u003ctd\u003e5\" Touch Screen\u003c\/td\u003e\n\u003ctd\u003e7\" Touch Screen\u003c\/td\u003e\n\u003ctd\u003e7\" Touch Screen\u003c\/td\u003e\n\u003ctd\u003e7\" Touch Screen\u003c\/td\u003e\n\u003ctd\u003e7\" Touch Screen\u003c\/td\u003e\n\u003ctd\u003e5\" Touch Screen\u003c\/td\u003e\n\u003ctd\u003e5\" Touch Screen\u003c\/td\u003e\n\u003ctd\u003e5\" Touch Screen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eCalibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eAuto\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eHeater Cover\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eAuto\u003c\/td\u003e\n\u003ctd\u003eAuto\u003c\/td\u003e\n\u003ctd\u003eAuto\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eData Storage Group\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003e200\u003c\/td\u003e\n\u003ctd\u003e200\u003c\/td\u003e\n\u003ctd\u003e200\u003c\/td\u003e\n\u003ctd\u003e200\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e40℃ - 199℃\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e40 ℃ - 200℃\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e40 ℃ - 160℃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eDrying mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eStandard, Fast, Soft\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eStandard, Fast, Soft, Step\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eStandard, Fast, Soft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eEnding mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"10\"\u003eAuto, Timing, Manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003ePan size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eΦ90 mm\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eΦ100 mm\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eΦ100 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"10\"\u003eRS-232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/body\u003e","brand":"U.S. Solid","offers":[{"title":"Default Title","offer_id":46324230357247,"sku":"JFHMA00002","price":1097.47,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/IMG_5516.jpg?v=1733397936"},{"product_id":"moisture-analyzer-110g-x-1mg-0-01-readability-touch-screen-halogen-moisture-balance-by-u-s-solid-html","title":"Moisture Analyzer-110g x 1mg, 0.01% Readability, Touch Screen Halogen Moisture Balance by U.S. Solid","description":"\u003cbody\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003cmeta content=\"width=device-width, initial-scale=1.0\" name=\"viewport\"\u003e\n\u003ctitle\u003eResponsive Page with Multiple Modules\u003c\/title\u003e\n\u003cstyle\u003e\n        \n        .desktop-img {\n            display: block;\n        }\n        .mobile-img {\n            display: none;\n        } \n\n        \n        .section-title {\n            font-size: 22px;\n            line-height: 22px;\n            font-weight: bold;\n            margin: 15px 0 5px; \n            font-family: Arial;\n        }\n        \n        .section-title2 {\n            font-size: 22px;\n            line-height: 22px;\n            font-weight: bold;\n            margin: 15px 0 3px; \n            font-family: Arial;\n        }\n        \n        .section-title3 {\n            font-size: 22px;\n            line-height: 22px;\n            font-weight: bold;\n            margin: 15px 0 10px; \n            font-family: Arial;\n        }\n\n        \n        .section-description {\n            font-size: 16px;\n            line-height: 26px;\n            margin-top: 0px;\n            margin-bottom: 5px; \n            font-family: Arial;\n        }\n        \n        .faq {\n            font-size: 16px; \n            margin: 0; \n            line-height: 26px; \n            background-color: #f2f2f2; \n            padding: 5px;\n        }\n        \n        .section-description2 {\n            font-size: 16px;\n            line-height: 26px;\n            margin: 0px; \n            font-family: Arial;\n        }\n        \n.parameters-table-wrapper {\n    overflow-x: auto; \n    -webkit-overflow-scrolling: touch; \n    margin-top: 0px;\n}\n\n\n.parameters-table {\n    width: 100%;\n    min-width: 1000px; \n    border-collapse: collapse;\n    margin-top: 0px;\n}\n\n.parameters-table th, .parameters-table td {\n    border-top: 1.2px solid #a6a6a6;  \n    border-bottom: 1.2px solid #a6a6a6;  \n    border-left: none;  \n    border-right: none;  \n    padding: 5px 2px;\n    text-align: left;\n    font-size: 16px;\n    line-height: 16px;\n}\n\n.parameters-table th {\n    background-color: #f2f2f2;\n    color: #2c2c2c;\n    font-weight: bold;\n}\n\n\n.parameters-table .bg-gray {\n    background-color: #f2f2f2;  \n}\n\n\n.options-table-wrapper {\n    overflow-x: auto; \n    -webkit-overflow-scrolling: touch; \n    margin-top: 0px;\n}\n\n.options-table {\n    width: 100%;\n    min-width: 1000px; \n    border-collapse: collapse;\n    margin-top: 0px;\n    box-shadow: 0 6px 25px rgba(0, 0, 0, 0.1); \n}\n\n.options-table th, .options-table td {\n    border: 2px solid #000;  \n    padding: 5px 2px;  \n    text-align: center;\n    font-size: 16px;\n    line-height: 16px;\n}\n\n.options-table th {\n    background-color: #f2f2f2;\n    color: #2c2c2c;\n    font-weight: bold;\n}\n\n\n.parameters-table2 {\n    width: 100%;\n    min-width: 1000px; \n    border-collapse: collapse;\n    margin-top: 0px;\n}\n\n.parameters-table2 th, .parameters-table2 td {\n    border-top: 1.2px solid #a6a6a6;  \n    border-bottom: 1.2px solid #a6a6a6;  \n    border-left: none;  \n    border-right: none;  \n    padding: 5px 2px;\n    text-align: center;\n    font-size: 16px;\n    line-height: 16px;\n}\n\n.parameters-table2 th {\n    background-color: #f2f2f2;\n    color: #2c2c2c;\n    font-weight: bold;\n}\n\n\n.parameters-table2 .bg-gray {\n    background-color: #f2f2f2;  \n}\n\n\n.options-table-wrapper2 {\n    overflow-x: auto; \n    -webkit-overflow-scrolling: touch; \n    margin-top: 0px;\n}\n\n\n@media (max-width: 768px) {\n    .parameters-table th, .parameters-table td {\n        font-size: 14px; \n        padding: 8px 4px; \n    }\n\n    \n    .options-table th, .options-table td {\n        font-size: 14px; \n        padding: 8px 4px;\n    }\n\n    .parameters-table-wrapper {\n        overflow-x: auto;\n    }\n    .parameters-table2 th, .parameters-table2 td {\n        font-size: 14px; \n        padding: 8px 4px; \n    }\n    .parameters-table-wrapper2 {\n        overflow-x: auto;\n    }\n    .desktop-img {\n                display: none; \n            }\n            .mobile-img {\n                display: block; \n            }\n    \n}\n\n@media (max-width: 480px) {\n    .parameters-table th, .parameters-table td {\n        font-size: 12px; \n        padding: 6px 3px; \n    }\n\n    \n    .options-table th, .options-table td {\n        font-size: 12px; \n    }\n\n    .parameters-table-wrapper {\n        overflow-x: auto;\n    }\n    .parameters-table2 th, .parameters-table2 td {\n        font-size: 12px; \n        padding: 6px 3px; \n    }\n    .parameters-table-wrapper2 {\n        overflow-x: auto;\n    }\n    .desktop-img {\n                display: none; \n            }\n            .mobile-img {\n                display: block; \n            }\n    \n}\n    \u003c\/style\u003e\n\u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHMA\/jfhma03-background.png\"\u003e\n\u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHMA\/USS-HMA03.png\"\u003e\n\u003cdiv\u003e\n\u003ch2 class=\"section-title\"\u003eIntroduction\u003c\/h2\u003e\n\u003cp class=\"section-description\"\u003e\n            The U.S. Solid USS-HMA03 Moisture Analyzer provides a high level of operating convenience and response sensitivity to facilitate determination of the moisture content of your samples.\u003cbr\u003e\n            It comes with smart functionalities that allows you to preset and store measuring methods, so you can access the options with ease. The device features a 450W halogen lamp and a premium transducer that delivers fast and accurate results even on low-moisture samples. USS-HMA03 moisture balance incorporates a high-definition 5-inch LCD color touch-panel that displays with higher accuracy and clarity any test result than general panel. Compact, practical, and easy to use, this moisture balance is a better choice for every lab.\u003cbr\u003eMoisture analyzers work according to the thermogravimetric principle. Moisture is determined by the direct weight lost by the sample due to heating from an intense halogen light.\n        \u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch2 class=\"section-title2\"\u003eApplications\u003c\/h2\u003e\n\u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHMA\/jfhma01-3%281%29.jpg\"\u003e\n\u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHMA\/jfhma-background.jpg\"\u003e\n\u003cdiv\u003e\n\u003ch2 class=\"section-title\"\u003eFeatures\u003c\/h2\u003e\n\u003cul class=\"section-description2\"\u003e\n\u003cli\u003eReadability: 0.001g (1mg)\u003c\/li\u003e\n\u003cli\u003eMoisture readability: 0.01%\u003c\/li\u003e\n\u003cli\u003eManual calibration\u003c\/li\u003e\n\u003cli\u003eWeighing sensor: High-end strain gauge\u003c\/li\u003e\n\u003cli\u003e5-inch LCD color touch-panel\u003c\/li\u003e\n\u003cli\u003e3 drying modes (standard\/fast\/soft)\u003c\/li\u003e\n\u003cli\u003e3 ending modes (automatic\/manual\/timing)\u003c\/li\u003e\n\u003cli\u003e20 groups of methods can be preset and stored\u003c\/li\u003e\n\u003cli\u003e3 kinds of result display (moisture percentage\/dry weight\/dry-weight percentage)\u003c\/li\u003e\n\u003cli\u003e50 \u003ca href=\"https:\/\/ussolid.com\/products\/aluminum-sample-pan-pack-of-50-for-u-s-solid-moisture-analyzers-html\"\u003esample pans\u003c\/a\u003e included\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch2 class=\"section-title\"\u003eMore Details\u003c\/h2\u003e\n\u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHMA\/jfhma03.jpg\"\u003e\n\u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHMA\/jfhma03-p-2.png\"\u003e\n\u003ch2 class=\"section-title\"\u003eUser Manual\u003c\/h2\u003e\n\u003cp class=\"section-description\"\u003e\n            For detailed information on calibration, installation, setup, and usage, please refer to the \u003ca href=\"https:\/\/file.ussolid.com\/content\/JFHMA\/USS-HMA03%20Instruction%20Manual.pdf\" target=\"_blank\"\u003euser manual\u003c\/a\u003e and watch the \u003ca href=\"https:\/\/www.youtube.com\/watch?v=dTHEa39WUbc\" target=\"_blank\"\u003etutorial video\u003c\/a\u003e.\n    \u003c\/p\u003e\n\u003ch2 class=\"section-title3\"\u003eTechnical Data\u003c\/h2\u003e\n\u003cdiv class=\"parameters-table-wrapper\"\u003e\n\u003ctable class=\"parameters-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSS-HMA03\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eCalibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eCapacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110 g\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eDisplays of results\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e[%m]\/ [%]\/ [g]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eWeight Readability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.001 g\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eCalibration Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eMoisture Readability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01%\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eStabilization Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 3s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eHeating Element\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e450W Halogen Lamp\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003ePan size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eΦ90mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e104℉-390.2℉ (40℃-199℃)\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRS-232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eTime setting range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 - 99 min\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003ePower\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110V 60Hz AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eDrying mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard\/ Fast\/ Soft\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.8*13.1*6.9 inches(200*340*180 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eEnding mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAuto\/ Timing\/ Manual\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.52 lbs (4.77 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ch2 class=\"section-title\"\u003eTroubleshooting\u003c\/h2\u003e\n\u003cp class=\"faq\"\u003e\u003cb\u003eProblem 1: Display remains off after switching on.\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003ePossible causes: Power cord is not connected\/ Power line fuse blown\/ Power supply interrupted\/ Instrument faulty\u003c\/p\u003e\n\u003cp class=\"faq\"\u003e\u003cb\u003eProblem 2: Display does not change when loading samples.\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003ePossible causes: The sample pan\/pan holder is not installed correctly.\u003c\/p\u003e\n\u003cp class=\"faq\"\u003e\u003cb\u003eProblem 3: Weight display is constantly changing or unstable.\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003ePossible causes: The sample pan is in contact with the draft shield or heating chamber\/ Air movement\/ Test bench vibration\/ Electromagnetic field interference\u003c\/p\u003e\n\u003cp class=\"faq\"\u003e\u003cb\u003eProblem 4: Drying does not start.\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003ePossible causes: Heating chamber open\/ Power cord is not connected\/ Power line fuse blown\u003c\/p\u003e\n\u003cp class=\"faq\"\u003e\u003cb\u003eProblem 5：Measurement takes too long.\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003ePossible causes: Incorrect ending mode selected\u003c\/p\u003e\n\u003cp class=\"faq\"\u003e\u003cb\u003eProblem 6: Measurements are not repeatable.\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003ePossible causes: The samples are not homogeneous.\/ Drying time is too short.\/ The temp selected is too high and the sample has been oxidized.\/ The temperature sensor is contaminated or defective.\/ The sample is not completely dry.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch2 class=\"section-title3\"\u003eCE Certified Quality \u0026amp; Safety\u003c\/h2\u003e\n\u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/CE\/CE.jpg\"\u003e\n\u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/CE\/CE.jpg\"\u003e\n\u003ch2 class=\"section-title3\"\u003eAll Options\u003c\/h2\u003e\n\u003cdiv class=\"parameters-table-wrapper2\"\u003e\n\u003ctable class=\"parameters-table2\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/ussolid.com\/products\/moisture-analyzer-110g-x-5mg-0-1-readability-halogen-moisture-balance-by-u-s-solid-html\" target=\"_blank\"\u003e\u003cstrong\u003eUSS-HMA01\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/ussolid.com\/products\/moisture-analyzer-110g-x-1mg-0-01-readability-halogen-moisture-balance-by-u-s-solid-html\" target=\"_blank\"\u003e\u003cstrong\u003eUSS-HMA02\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eUSS-HMA03\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/ussolid.com\/products\/moisture-analyzer-0-001-g-0-01-readability-moisture-balance-7-inch-touch-screen-html\" target=\"_blank\"\u003e\u003cstrong\u003eUSS-HMA11\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/ussolid.com\/products\/moisture-analyzer-0-001-g-0-01-readability-moisture-balance-7-inch-touch-screen-automatic-door-html\" target=\"_blank\"\u003e\u003cstrong\u003eUSS-HMA12\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/ussolid.com\/products\/moisture-analyzer-0-0001-g-0-001-readability-moisture-balance-7-inch-touch-screen-automatic-door-html\" target=\"_blank\"\u003e\u003cstrong\u003eUSS-HMA13\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/ussolid.com\/products\/moisture-analyzer-0-0001-g-0-001-readability-moisture-balance-7-inch-touch-screen-internal-calibration-and-automatic-door-html\" target=\"_blank\"\u003e\u003cstrong\u003eUSS-HMA14\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/ussolid.com\/products\/moisture-analyzer-0-01-g-0-1-readability-moisture-balance-5-inch-touch-screen-110-g-capacity-html\" target=\"_blank\"\u003e\u003cstrong\u003eUSS-HMA21\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/ussolid.com\/products\/moisture-analyzer-0-005-g-0-05-readability-moisture-balance-5-inch-touch-screen-110-g-capacity-html\" target=\"_blank\"\u003e\u003cstrong\u003eUSS-HMA22\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/ussolid.com\/products\/moisture-analyzer-0-001-g-0-01-readability-moisture-balance-5-inch-touch-screen-110-g-capacity-html\" target=\"_blank\"\u003e\u003cstrong\u003eUSS-HMA23\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003ePositioning\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eMainstream\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eHigh-end\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eEconomical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eWeight Readability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.005 g\u003c\/td\u003e\n\u003ctd\u003e0.001 g\u003c\/td\u003e\n\u003ctd\u003e0.001 g\u003c\/td\u003e\n\u003ctd\u003e0.001 g\u003c\/td\u003e\n\u003ctd\u003e0.001 g\u003c\/td\u003e\n\u003ctd\u003e0.0001 g\u003c\/td\u003e\n\u003ctd\u003e0.0001 g\u003c\/td\u003e\n\u003ctd\u003e0.01 g\u003c\/td\u003e\n\u003ctd\u003e0.005 g\u003c\/td\u003e\n\u003ctd\u003e0.001 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eMoisture Readability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 %\u003c\/td\u003e\n\u003ctd\u003e0.01 %\u003c\/td\u003e\n\u003ctd\u003e0.01 %\u003c\/td\u003e\n\u003ctd\u003e0.01 %\u003c\/td\u003e\n\u003ctd\u003e0.01 %\u003c\/td\u003e\n\u003ctd\u003e0.001 %\u003c\/td\u003e\n\u003ctd\u003e0.001 %\u003c\/td\u003e\n\u003ctd\u003e0.1 %\u003c\/td\u003e\n\u003ctd\u003e0.05 %\u003c\/td\u003e\n\u003ctd\u003e0.01 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eWeighing Sensor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eHigh-end strain gauge\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eHigh-end strain gauge\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eElectromagnetic force\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eStrain gauge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eControl Panel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePush Button\u003c\/td\u003e\n\u003ctd\u003ePush Button\u003c\/td\u003e\n\u003ctd\u003e5\" Touch Screen\u003c\/td\u003e\n\u003ctd\u003e7\" Touch Screen\u003c\/td\u003e\n\u003ctd\u003e7\" Touch Screen\u003c\/td\u003e\n\u003ctd\u003e7\" Touch Screen\u003c\/td\u003e\n\u003ctd\u003e7\" Touch Screen\u003c\/td\u003e\n\u003ctd\u003e5\" Touch Screen\u003c\/td\u003e\n\u003ctd\u003e5\" Touch Screen\u003c\/td\u003e\n\u003ctd\u003e5\" Touch Screen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eCalibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eAuto\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eHeater Cover\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eAuto\u003c\/td\u003e\n\u003ctd\u003eAuto\u003c\/td\u003e\n\u003ctd\u003eAuto\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eData Storage Group\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003e200\u003c\/td\u003e\n\u003ctd\u003e200\u003c\/td\u003e\n\u003ctd\u003e200\u003c\/td\u003e\n\u003ctd\u003e200\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e40℃ - 199℃\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e40 ℃ - 200℃\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e40 ℃ - 160℃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eDrying mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eStandard, Fast, Soft\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eStandard, Fast, Soft, Step\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eStandard, Fast, Soft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eEnding mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"10\"\u003eAuto, Timing, Manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003ePan size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eΦ90 mm\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eΦ100 mm\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eΦ100 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"10\"\u003eRS-232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/body\u003e","brand":"U.S. Solid","offers":[{"title":"Default Title","offer_id":46324231504127,"sku":"JFHMA00003","price":1247.47,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/MG_5937-1.jpg?v=1733398163"},{"product_id":"aluminum-sample-pan-pack-of-50-for-u-s-solid-moisture-analyzers-html","title":"50-Pack Aluminum Sample Pan for U.S. Solid Moisture Analyzers","description":"\u003cdiv class=\"powr-popup\"\u003e\n\u003cp\u003e\u003cspan style=\"font-size: medium;\"\u003eThe Aluminum Sample Pan is designed for moisture analysis in laboratories or industrial settings. With a diameter of φ90 mm, they are made from quality, corrosion-resistant Aluminum. \u003cspan\u003eEach pack contains 50 pans, compatible with U.S. Solid moisture analyzer and other moisture analyzer with 90 mm diameter. \u003c\/span\u003eThese pans provide a cost-effective, versatile, and durable solution for moisture analysis needs.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"ca65c0ed_1637561501\" class=\"powr-popup\"\u003e\u003cspan style=\"font-size: medium;\"\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv class=\"powr-popup\"\u003e\u003cspan style=\"font-size: medium;\"\u003eQuantity: 50\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv class=\"powr-popup\"\u003e\u003cspan style=\"font-size: medium;\"\u003eSize: φ90 mm\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv class=\"powr-popup\"\u003e\u003cspan style=\"font-size: medium;\"\u003eMaterial: Aluminum\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv class=\"powr-popup\"\u003e\u003cspan style=\"font-size: medium;\"\u003e \u003c\/span\u003e\u003c\/div\u003e","brand":"U.S. Solid","offers":[{"title":"Default Title","offer_id":46324237041919,"sku":"JFHMA00005","price":35.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/2.jpg?v=1733399356"},{"product_id":"moisture-analyzer-0-001-g-0-01-readability-moisture-balance-7-inch-touch-screen-html","title":"Moisture Analyzer - 0.001 g, 0.01% Readability Moisture Balance, 7-inch Touch Screen","description":"\u003cbody\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003cmeta content=\"width=device-width, initial-scale=1.0\" name=\"viewport\"\u003e\n\u003ctitle\u003eResponsive Page with Multiple Modules\u003c\/title\u003e\n\u003cstyle\u003e\n        \n        .desktop-img {\n            display: block;\n        }\n        .mobile-img {\n            display: none;\n        } \n\n        \n        .section-title {\n            font-size: 22px;\n            line-height: 22px;\n            font-weight: bold;\n            margin: 15px 0 5px; \n            font-family: Arial;\n        }\n        \n        .section-title2 {\n            font-size: 22px;\n            line-height: 22px;\n            font-weight: bold;\n            margin: 15px 0 3px; \n            font-family: Arial;\n        }\n        \n        .section-title3 {\n            font-size: 22px;\n            line-height: 22px;\n            font-weight: bold;\n            margin: 15px 0 10px; \n            font-family: Arial;\n        }\n\n        \n        .section-description {\n            font-size: 16px;\n            line-height: 26px;\n            margin-top: 0px;\n            margin-bottom: 5px; \n            font-family: Arial;\n        }\n        \n        .faq {\n            font-size: 16px; \n            margin: 0; \n            line-height: 26px; \n            background-color: #f2f2f2; \n            padding: 5px;\n        }\n        \n        .section-description2 {\n            font-size: 16px;\n            line-height: 26px;\n            margin: 0px; \n            font-family: Arial;\n        }\n        \n.parameters-table-wrapper {\n    overflow-x: auto; \n    -webkit-overflow-scrolling: touch; \n    margin-top: 0px;\n}\n\n\n.parameters-table {\n    width: 100%;\n    min-width: 1000px; \n    border-collapse: collapse;\n    margin-top: 0px;\n}\n\n.parameters-table th, .parameters-table td {\n    border-top: 1.2px solid #a6a6a6;  \n    border-bottom: 1.2px solid #a6a6a6;  \n    border-left: none;  \n    border-right: none;  \n    padding: 5px 2px;\n    text-align: left;\n    font-size: 16px;\n    line-height: 16px;\n}\n\n.parameters-table th {\n    background-color: #f2f2f2;\n    color: #2c2c2c;\n    font-weight: bold;\n}\n\n\n.parameters-table .bg-gray {\n    background-color: #f2f2f2;  \n}\n\n\n.options-table-wrapper {\n    overflow-x: auto; \n    -webkit-overflow-scrolling: touch; \n    margin-top: 0px;\n}\n\n.options-table {\n    width: 100%;\n    min-width: 1000px; \n    border-collapse: collapse;\n    margin-top: 0px;\n    box-shadow: 0 6px 25px rgba(0, 0, 0, 0.1); \n}\n\n.options-table th, .options-table td {\n    border: 2px solid #000;  \n    padding: 5px 2px;  \n    text-align: center;\n    font-size: 16px;\n    line-height: 16px;\n}\n\n.options-table th {\n    background-color: #f2f2f2;\n    color: #2c2c2c;\n    font-weight: bold;\n}\n\n\n.parameters-table2 {\n    width: 100%;\n    min-width: 1000px; \n    border-collapse: collapse;\n    margin-top: 0px;\n}\n\n.parameters-table2 th, .parameters-table2 td {\n    border-top: 1.2px solid #a6a6a6;  \n    border-bottom: 1.2px solid #a6a6a6;  \n    border-left: none;  \n    border-right: none;  \n    padding: 5px 2px;\n    text-align: center;\n    font-size: 16px;\n    line-height: 16px;\n}\n\n.parameters-table2 th {\n    background-color: #f2f2f2;\n    color: #2c2c2c;\n    font-weight: bold;\n}\n\n\n.parameters-table2 .bg-gray {\n    background-color: #f2f2f2;  \n}\n\n\n.options-table-wrapper2 {\n    overflow-x: auto; \n    -webkit-overflow-scrolling: touch; \n    margin-top: 0px;\n}\n\n\n@media (max-width: 768px) {\n    .parameters-table th, .parameters-table td {\n        font-size: 14px; \n        padding: 8px 4px; \n    }\n\n    \n    .options-table th, .options-table td {\n        font-size: 14px; \n        padding: 8px 4px;\n    }\n\n    .parameters-table-wrapper {\n        overflow-x: auto;\n    }\n    .parameters-table2 th, .parameters-table2 td {\n        font-size: 14px; \n        padding: 8px 4px; \n    }\n    .parameters-table-wrapper2 {\n        overflow-x: auto;\n    }\n    .desktop-img {\n                display: none; \n            }\n            .mobile-img {\n                display: block; \n            }\n    \n}\n\n@media (max-width: 480px) {\n    .parameters-table th, .parameters-table td {\n        font-size: 12px; \n        padding: 6px 3px; \n    }\n\n    \n    .options-table th, .options-table td {\n        font-size: 12px; \n    }\n\n    .parameters-table-wrapper {\n        overflow-x: auto;\n    }\n    .parameters-table2 th, .parameters-table2 td {\n        font-size: 12px; \n        padding: 6px 3px; \n    }\n    .parameters-table-wrapper2 {\n        overflow-x: auto;\n    }\n    .desktop-img {\n                display: none; \n            }\n            .mobile-img {\n                display: block; \n            }\n    \n}\n    \u003c\/style\u003e\n\u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHMA\/jfhma11-background.png\"\u003e\n\u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHMA\/USS-HMA11.png\"\u003e\n\u003cdiv\u003e\n\u003ch2 class=\"section-title\"\u003eIntroduction\u003c\/h2\u003e\n\u003cp class=\"section-description\"\u003e\n            The U.S. Solid USS-HMA11 Moisture Analyzer provides a high level of operating convenience and response sensitivity to facilitate determination of the moisture content of your samples.\u003cbr\u003e\n            It comes with smart functionalities that allows you to preset and store measuring methods, so you can access the options with ease. The device features a 450W halogen lamp and a premium transducer that delivers fast and accurate results even on low-moisture samples. USS-HMA11 moisture balance incorporates a high-definition 7-inch LCD color touch-panel that displays with higher accuracy and clarity any test result than general panel. Compact, practical, and easy to use, this moisture balance is a better choice for every lab.\u003cbr\u003eMoisture analyzers work according to the thermogravimetric principle. Moisture is determined by the direct weight lost by the sample due to heating from an intense halogen light.\n        \u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch2 class=\"section-title2\"\u003eApplications\u003c\/h2\u003e\n\u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHMA\/jfhma01-3%281%29.jpg\"\u003e\n\u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHMA\/jfhma-background.jpg\"\u003e\n\u003cdiv\u003e\n\u003ch2 class=\"section-title\"\u003eFeatures\u003c\/h2\u003e\n\u003cul class=\"section-description2\"\u003e\n\u003cli\u003eReadability: 0.001g (1mg)\u003c\/li\u003e\n\u003cli\u003eMoisture readability: 0.01%\u003c\/li\u003e\n\u003cli\u003eManual calibration\u003c\/li\u003e\n\u003cli\u003eWeighing sensor: High-end strain gauge\u003c\/li\u003e\n\u003cli\u003e7-inch LCD color touch-panel: Displays real-time testing curve\u003c\/li\u003e\n\u003cli\u003ePrecise temperature control: Adjustable from 40°C to 200°C in 1°C increments\u003c\/li\u003e\n\u003cli\u003eNoise control: Silent fan ensures a quiet testing environment\u003c\/li\u003e\n\u003cli\u003eUser authentication: Allows setting up an admin and multiple operators, each with unique passwords for secure access to testing data.\u003c\/li\u003e\n\u003cli\u003e4 drying modes (standard\/fast\/soft\/step)\u003c\/li\u003e\n\u003cli\u003e3 ending modes (automatic\/manual\/timing)\u003c\/li\u003e\n\u003cli\u003e200 groups of methods can be preset and stored\u003c\/li\u003e\n\u003cli\u003e3 kinds of result display (moisture percentage\/dry weight\/dry-weight percentage)\u003c\/li\u003e\n\u003cli\u003e50 sample pans included\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch2 class=\"section-title\"\u003eMore Details\u003c\/h2\u003e\n\u003cp\u003e\u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHMA\/jfhma11-e-1.jpg\"\u003e \u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHMA\/jfhma11-e-2.jpg\"\u003e \u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHMA\/jfhma12-e-1-p.jpg\"\u003e \u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHMA\/jfhma11-e-2-p.jpg\"\u003e \u003c\/p\u003e\n\u003ch2 class=\"section-title\"\u003eUser Manual\u003c\/h2\u003e\n\u003cp class=\"section-description\"\u003e\n            For detailed information on calibration, installation, setup, and usage, please refer to the \u003ca href=\"https:\/\/file.ussolid.com\/content\/JFHMA\/Instruction%20Manual%20-%20USS-HMA1X%20Moisture%20Analyzer.pdf\" target=\"_blank\"\u003euser manual\u003c\/a\u003e or watch the \u003ca href=\"https:\/\/youtu.be\/q50Oz81kwzI?list=TLGG7A8nrVXMxpcwMTA0MjAyNQ\" target=\"_blank\"\u003etutorial video\u003c\/a\u003e.\n    \u003c\/p\u003e\n\u003ch2 class=\"section-title3\"\u003eTechnical Data\u003c\/h2\u003e\n\u003cdiv class=\"parameters-table-wrapper\"\u003e\n\u003ctable class=\"parameters-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSS-HMA11\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eCalibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eCapacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110 g\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eDisplays of results\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e[%m]\/ [%]\/ [g]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eWeight Readability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.001 g\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eCalibration Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eMoisture Readability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01%\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eStabilization Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 3s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eHeating Element\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e450W Halogen Lamp\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003ePan size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/ussolid.com\/products\/50-pack-aluminum-sample-pan-100-mm-for-u-s-solid-moisture-analyzers?_pos=1\u0026amp;_sid=4dab01060\u0026amp;_ss=r\" target=\"_blank\"\u003eΦ100mm\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eOperating temperature range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e104℉-392℉ (40℃-200℃)\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRS-232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eAmbient temperature range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e41℉-95℉ (5℃-35℃)\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eHeater Cover\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eTime setting range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 - 99 min\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003ePower\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110V 60Hz AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eDrying mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard\/ Fast\/ Soft\/ Step\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eProduct dimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.5*16.6*6.3 inches(190*420*160 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eEnding mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAuto\/ Timing\/ Manual\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16.78 lbs (7.61 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ch2 class=\"section-title\"\u003eTroubleshooting\u003c\/h2\u003e\n\u003cp class=\"faq\"\u003e\u003cb\u003eProblem 1: Display remains off after switching on.\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003ePossible causes: Power cord is not connected\/ Power line fuse blown\/ Power supply interrupted\/ Instrument faulty\u003c\/p\u003e\n\u003cp class=\"faq\"\u003e\u003cb\u003eProblem 2: Display does not change when loading samples.\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003ePossible causes: The sample pan\/pan holder is not installed correctly.\u003c\/p\u003e\n\u003cp class=\"faq\"\u003e\u003cb\u003eProblem 3: Weight display is constantly changing or unstable.\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003ePossible causes: The sample pan is in contact with the draft shield or heating chamber\/ Air movement\/ Test bench vibration\/ Electromagnetic field interference\u003c\/p\u003e\n\u003cp class=\"faq\"\u003e\u003cb\u003eProblem 4: Drying does not start.\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003ePossible causes: Heating chamber open\/ Power cord is not connected\/ Power line fuse blown\u003c\/p\u003e\n\u003cp class=\"faq\"\u003e\u003cb\u003eProblem 5：Measurement takes too long.\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003ePossible causes: Incorrect ending mode selected\u003c\/p\u003e\n\u003cp class=\"faq\"\u003e\u003cb\u003eProblem 6: Measurements are not repeatable.\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003ePossible causes: The samples are not homogeneous.\/ Drying time is too short.\/ The temp selected is too high and the sample has been oxidized.\/ The temperature sensor is contaminated or defective.\/ The sample is not completely dry.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch2 class=\"section-title3\"\u003eCE Certified Quality \u0026amp; Safety\u003c\/h2\u003e\n\u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/CE\/CE.jpg\"\u003e\n\u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/CE\/CE.jpg\"\u003e\n\u003ch2 class=\"section-title3\"\u003eAll Options\u003c\/h2\u003e\n\u003cdiv class=\"parameters-table-wrapper2\"\u003e\n\u003ctable class=\"parameters-table2\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/ussolid.com\/products\/moisture-analyzer-110g-x-5mg-0-1-readability-halogen-moisture-balance-by-u-s-solid-html\" target=\"_blank\"\u003e\u003cstrong\u003eUSS-HMA01\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/ussolid.com\/products\/moisture-analyzer-110g-x-1mg-0-01-readability-halogen-moisture-balance-by-u-s-solid-html\" target=\"_blank\"\u003e\u003cstrong\u003eUSS-HMA02\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/ussolid.com\/products\/moisture-analyzer-110g-x-1mg-0-01-readability-touch-screen-halogen-moisture-balance-by-u-s-solid-html\" target=\"_blank\"\u003e\u003cstrong\u003eUSS-HMA03\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eUSS-HMA11\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/ussolid.com\/products\/moisture-analyzer-0-001-g-0-01-readability-moisture-balance-7-inch-touch-screen-automatic-door-html\" target=\"_blank\"\u003e\u003cstrong\u003eUSS-HMA12\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/ussolid.com\/products\/moisture-analyzer-0-0001-g-0-001-readability-moisture-balance-7-inch-touch-screen-automatic-door-html\" target=\"_blank\"\u003e\u003cstrong\u003eUSS-HMA13\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/ussolid.com\/products\/moisture-analyzer-0-0001-g-0-001-readability-moisture-balance-7-inch-touch-screen-internal-calibration-and-automatic-door-html\" target=\"_blank\"\u003e\u003cstrong\u003eUSS-HMA14\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/ussolid.com\/products\/moisture-analyzer-0-01-g-0-1-readability-moisture-balance-5-inch-touch-screen-110-g-capacity-html\" target=\"_blank\"\u003e\u003cstrong\u003eUSS-HMA21\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/ussolid.com\/products\/moisture-analyzer-0-005-g-0-05-readability-moisture-balance-5-inch-touch-screen-110-g-capacity-html\" target=\"_blank\"\u003e\u003cstrong\u003eUSS-HMA22\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/ussolid.com\/products\/moisture-analyzer-0-001-g-0-01-readability-moisture-balance-5-inch-touch-screen-110-g-capacity-html\" target=\"_blank\"\u003e\u003cstrong\u003eUSS-HMA23\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003ePositioning\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eMainstream\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eHigh-end\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eEconomical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eWeight Readability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.005 g\u003c\/td\u003e\n\u003ctd\u003e0.001 g\u003c\/td\u003e\n\u003ctd\u003e0.001 g\u003c\/td\u003e\n\u003ctd\u003e0.001 g\u003c\/td\u003e\n\u003ctd\u003e0.001 g\u003c\/td\u003e\n\u003ctd\u003e0.0001 g\u003c\/td\u003e\n\u003ctd\u003e0.0001 g\u003c\/td\u003e\n\u003ctd\u003e0.01 g\u003c\/td\u003e\n\u003ctd\u003e0.005 g\u003c\/td\u003e\n\u003ctd\u003e0.001 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eMoisture Readability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 %\u003c\/td\u003e\n\u003ctd\u003e0.01 %\u003c\/td\u003e\n\u003ctd\u003e0.01 %\u003c\/td\u003e\n\u003ctd\u003e0.01 %\u003c\/td\u003e\n\u003ctd\u003e0.01 %\u003c\/td\u003e\n\u003ctd\u003e0.001 %\u003c\/td\u003e\n\u003ctd\u003e0.001 %\u003c\/td\u003e\n\u003ctd\u003e0.1 %\u003c\/td\u003e\n\u003ctd\u003e0.05 %\u003c\/td\u003e\n\u003ctd\u003e0.01 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eWeighing Sensor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eHigh-end strain gauge\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eHigh-end strain gauge\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eElectromagnetic force\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eStrain gauge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eControl Panel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePush Button\u003c\/td\u003e\n\u003ctd\u003ePush Button\u003c\/td\u003e\n\u003ctd\u003e5\" Touch Screen\u003c\/td\u003e\n\u003ctd\u003e7\" Touch Screen\u003c\/td\u003e\n\u003ctd\u003e7\" Touch Screen\u003c\/td\u003e\n\u003ctd\u003e7\" Touch Screen\u003c\/td\u003e\n\u003ctd\u003e7\" Touch Screen\u003c\/td\u003e\n\u003ctd\u003e5\" Touch Screen\u003c\/td\u003e\n\u003ctd\u003e5\" Touch Screen\u003c\/td\u003e\n\u003ctd\u003e5\" Touch Screen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eCalibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eAuto\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eHeater Cover\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eAuto\u003c\/td\u003e\n\u003ctd\u003eAuto\u003c\/td\u003e\n\u003ctd\u003eAuto\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eData Storage Group\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003e200\u003c\/td\u003e\n\u003ctd\u003e200\u003c\/td\u003e\n\u003ctd\u003e200\u003c\/td\u003e\n\u003ctd\u003e200\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e40℃ - 199℃\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e40 ℃ - 200℃\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e40 ℃ - 160℃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eDrying mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eStandard, Fast, Soft\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eStandard, Fast, Soft, Step\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eStandard, Fast, Soft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eEnding mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"10\"\u003eAuto, Timing, Manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003ePan size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eΦ90 mm\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eΦ100 mm\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eΦ100 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"10\"\u003eRS-232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/body\u003e","brand":"U.S. Solid","offers":[{"title":"Default Title","offer_id":46324255752447,"sku":"JFHMA00011","price":1347.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/main-new.jpg?v=1733398309"},{"product_id":"moisture-analyzer-0-0001-g-0-001-readability-moisture-balance-7-inch-touch-screen-internal-calibration-and-automatic-door-html","title":"Moisture Analyzer - 0.0001 g, 0.001% Readability Moisture Balance, 7-inch Touch Screen, Internal Calibration and Automatic Door","description":"\u003cbody\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003cmeta content=\"width=device-width, initial-scale=1.0\" name=\"viewport\"\u003e\n\u003ctitle\u003eResponsive Page with Multiple Modules\u003c\/title\u003e\n\u003cstyle\u003e\n        \n        .desktop-img {\n            display: block;\n        }\n        .mobile-img {\n            display: none;\n        } \n\n        \n        .section-title {\n            font-size: 22px;\n            line-height: 22px;\n            font-weight: bold;\n            margin: 15px 0 5px; \n            font-family: Arial;\n        }\n        \n        .section-title2 {\n            font-size: 22px;\n            line-height: 22px;\n            font-weight: bold;\n            margin: 15px 0 3px; \n            font-family: Arial;\n        }\n        \n        .section-title3 {\n            font-size: 22px;\n            line-height: 22px;\n            font-weight: bold;\n            margin: 15px 0 10px; \n            font-family: Arial;\n        }\n\n        \n        .section-description {\n            font-size: 16px;\n            line-height: 26px;\n            margin-top: 0px;\n            margin-bottom: 5px; \n            font-family: Arial;\n        }\n        \n        .faq {\n            font-size: 16px; \n            margin: 0; \n            line-height: 26px; \n            background-color: #f2f2f2; \n            padding: 5px;\n        }\n        \n        .section-description2 {\n            font-size: 16px;\n            line-height: 26px;\n            margin: 0px; \n            font-family: Arial;\n        }\n        \n.parameters-table-wrapper {\n    overflow-x: auto; \n    -webkit-overflow-scrolling: touch; \n    margin-top: 0px;\n}\n\n\n.parameters-table {\n    width: 100%;\n    min-width: 1000px; \n    border-collapse: collapse;\n    margin-top: 0px;\n}\n\n.parameters-table th, .parameters-table td {\n    border-top: 1.2px solid #a6a6a6;  \n    border-bottom: 1.2px solid #a6a6a6;  \n    border-left: none;  \n    border-right: none;  \n    padding: 5px 2px;\n    text-align: left;\n    font-size: 16px;\n    line-height: 16px;\n}\n\n.parameters-table th {\n    background-color: #f2f2f2;\n    color: #2c2c2c;\n    font-weight: bold;\n}\n\n\n.parameters-table .bg-gray {\n    background-color: #f2f2f2;  \n}\n\n\n.options-table-wrapper {\n    overflow-x: auto; \n    -webkit-overflow-scrolling: touch; \n    margin-top: 0px;\n}\n\n.options-table {\n    width: 100%;\n    min-width: 1000px; \n    border-collapse: collapse;\n    margin-top: 0px;\n    box-shadow: 0 6px 25px rgba(0, 0, 0, 0.1); \n}\n\n.options-table th, .options-table td {\n    border: 2px solid #000;  \n    padding: 5px 2px;  \n    text-align: center;\n    font-size: 16px;\n    line-height: 16px;\n}\n\n.options-table th {\n    background-color: #f2f2f2;\n    color: #2c2c2c;\n    font-weight: bold;\n}\n\n\n.parameters-table2 {\n    width: 100%;\n    min-width: 1000px; \n    border-collapse: collapse;\n    margin-top: 0px;\n}\n\n.parameters-table2 th, .parameters-table2 td {\n    border-top: 1.2px solid #a6a6a6;  \n    border-bottom: 1.2px solid #a6a6a6;  \n    border-left: none;  \n    border-right: none;  \n    padding: 5px 2px;\n    text-align: center;\n    font-size: 16px;\n    line-height: 16px;\n}\n\n.parameters-table2 th {\n    background-color: #f2f2f2;\n    color: #2c2c2c;\n    font-weight: bold;\n}\n\n\n.parameters-table2 .bg-gray {\n    background-color: #f2f2f2;  \n}\n\n\n.options-table-wrapper2 {\n    overflow-x: auto; \n    -webkit-overflow-scrolling: touch; \n    margin-top: 0px;\n}\n\n\n@media (max-width: 768px) {\n    .parameters-table th, .parameters-table td {\n        font-size: 14px; \n        padding: 8px 4px; \n    }\n\n    \n    .options-table th, .options-table td {\n        font-size: 14px; \n        padding: 8px 4px;\n    }\n\n    .parameters-table-wrapper {\n        overflow-x: auto;\n    }\n    .parameters-table2 th, .parameters-table2 td {\n        font-size: 14px; \n        padding: 8px 4px; \n    }\n    .parameters-table-wrapper2 {\n        overflow-x: auto;\n    }\n    .desktop-img {\n                display: none; \n            }\n            .mobile-img {\n                display: block; \n            }\n    \n}\n\n@media (max-width: 480px) {\n    .parameters-table th, .parameters-table td {\n        font-size: 12px; \n        padding: 6px 3px; \n    }\n\n    \n    .options-table th, .options-table td {\n        font-size: 12px; \n    }\n\n    .parameters-table-wrapper {\n        overflow-x: auto;\n    }\n    .parameters-table2 th, .parameters-table2 td {\n        font-size: 12px; \n        padding: 6px 3px; \n    }\n    .parameters-table-wrapper2 {\n        overflow-x: auto;\n    }\n    .desktop-img {\n                display: none; \n            }\n            .mobile-img {\n                display: block; \n            }\n    \n}\n    \u003c\/style\u003e\n\u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHMA\/jfhma14-background.png\"\u003e\n\u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHMA\/USS-HMA14.png\"\u003e\n\u003cdiv\u003e\n\u003ch2 class=\"section-title\"\u003eIntroduction\u003c\/h2\u003e\n\u003cp class=\"section-description\"\u003e\n            The U.S. Solid USS-HMA14 Moisture Analyzer provides a high level of operating convenience and response sensitivity to facilitate determination of the moisture content of your samples.\u003cbr\u003e\n            It comes with smart functionalities that allows you to preset and store measuring methods, so you can access the options with ease. The device features a 450W halogen lamp and a electromagnetic force transducer that delivers fast and accurate results even on low-moisture samples. USS-HMA14 moisture balance incorporates a high-definition 7-inch LCD color touch-panel that displays with higher accuracy and clarity any test result than general panel. Compact, practical, and easy to use, this moisture balance is a better choice for every lab.\u003cbr\u003eMoisture analyzers work according to the thermogravimetric principle. Moisture is determined by the direct weight lost by the sample due to heating from an intense halogen light.\n        \u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch2 class=\"section-title2\"\u003eApplications\u003c\/h2\u003e\n\u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHMA\/jfhma01-3%281%29.jpg\"\u003e\n\u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHMA\/jfhma-background.jpg\"\u003e\n\u003cdiv\u003e\n\u003ch2 class=\"section-title\"\u003eFeatures\u003c\/h2\u003e\n\u003cul class=\"section-description2\"\u003e\n\u003cli\u003eReadability: 0.0001g (0.1mg)\u003c\/li\u003e\n\u003cli\u003eMoisture readability: 0.001%\u003c\/li\u003e\n\u003cli\u003eAutomatic calibration\u003c\/li\u003e\n\u003cli\u003eElectromagnetic force transducer\u003c\/li\u003e\n\u003cli\u003eAutomatic door mechanism: Features a convenient automatic door that can be operated via touch commands on the screen.\u003c\/li\u003e\n\u003cli\u003e7-inch LCD color touch-panel: Displays real-time testing curve\u003c\/li\u003e\n\u003cli\u003ePrecise temperature control: Adjustable from 40°C to 200°C in 1°C increments\u003c\/li\u003e\n\u003cli\u003eNoise control: Silent fan ensures a quiet testing environment\u003c\/li\u003e\n\u003cli\u003eUser authentication: Allows setting up an admin and multiple operators, each with unique passwords for secure access to testing data.\u003c\/li\u003e\n\u003cli\u003e4 drying modes (standard\/fast\/soft\/step)\u003c\/li\u003e\n\u003cli\u003e3 ending modes (automatic\/manual\/timing)\u003c\/li\u003e\n\u003cli\u003e200 groups of methods can be preset and stored\u003c\/li\u003e\n\u003cli\u003e3 kinds of result display (moisture percentage\/dry weight\/dry-weight percentage)\u003c\/li\u003e\n\u003cli\u003e50 sample pans included\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch2 class=\"section-title\"\u003eMore Details\u003c\/h2\u003e\n\u003cp\u003e\u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHMA\/jfhma14-e-1.jpg\"\u003e \u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHMA\/jfhma14-e-2.jpg\"\u003e \u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHMA\/jfhma14-e-3.jpg\"\u003e \u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHMA\/jfhma14-e-1-p.jpg\"\u003e \u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHMA\/jfhma14-e-2-p.jpg\"\u003e \u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHMA\/jfhma14-e-3-p.jpg\"\u003e\u003c\/p\u003e\n\u003ch2 class=\"section-title\"\u003eUser Manual\u003c\/h2\u003e\n\u003cp class=\"section-description\"\u003e\n            For detailed information on calibration, installation, setup, and usage, please refer to the \u003ca href=\"https:\/\/file.ussolid.com\/content\/JFHMA\/Instruction%20Manual%20-%20USS-HMA1X%20Moisture%20Analyzer.pdf\" target=\"_blank\"\u003euser manual\u003c\/a\u003e or watch the \u003ca href=\"https:\/\/youtu.be\/q50Oz81kwzI?list=TLGG7A8nrVXMxpcwMTA0MjAyNQ\" target=\"_blank\"\u003etutorial video\u003c\/a\u003e.\n    \u003c\/p\u003e\n\u003ch2 class=\"section-title3\"\u003eTechnical Data\u003c\/h2\u003e\n\u003cdiv class=\"parameters-table-wrapper\"\u003e\n\u003ctable class=\"parameters-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSS-HMA14\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eCalibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAutomatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eCapacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110 g\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eDisplays of results\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e[%m]\/ [%]\/ [g]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eWeight Readability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.0001 g\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eCalibration Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eMoisture Readability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.001 %\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eStabilization Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 3s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eHeating Element\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e450W Halogen Lamp\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003ePan size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/ussolid.com\/products\/50-pack-aluminum-sample-pan-100-mm-for-u-s-solid-moisture-analyzers?_pos=1\u0026amp;_sid=4dab01060\u0026amp;_ss=r\" target=\"_blank\"\u003eΦ100mm\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eOperating temperature range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e104℉-392℉ (40℃-200℃)\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRS-232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eAmbient temperature range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e41℉-95℉ (5℃-35℃)\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eHeater Cover\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAutomatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eTime setting range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 - 99 min\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003ePower\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110V 60Hz AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eDrying mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard\/ Fast\/ Soft\/ Step\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eProduct dimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.8*16.5*7.5 inches(200*420*190 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eEnding mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAuto\/ Timing\/ Manual\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16.78 lbs (7.61 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ch2 class=\"section-title\"\u003eTroubleshooting\u003c\/h2\u003e\n\u003cp class=\"faq\"\u003e\u003cb\u003eProblem 1: Display remains off after switching on.\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003ePossible causes: Power cord is not connected\/ Power line fuse blown\/ Power supply interrupted\/ Instrument faulty\u003c\/p\u003e\n\u003cp class=\"faq\"\u003e\u003cb\u003eProblem 2: Display does not change when loading samples.\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003ePossible causes: The sample pan\/pan holder is not installed correctly.\u003c\/p\u003e\n\u003cp class=\"faq\"\u003e\u003cb\u003eProblem 3: Weight display is constantly changing or unstable.\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003ePossible causes: The sample pan is in contact with the draft shield or heating chamber\/ Air movement\/ Test bench vibration\/ Electromagnetic field interference\u003c\/p\u003e\n\u003cp class=\"faq\"\u003e\u003cb\u003eProblem 4: Drying does not start.\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003ePossible causes: Heating chamber open\/ Power cord is not connected\/ Power line fuse blown\u003c\/p\u003e\n\u003cp class=\"faq\"\u003e\u003cb\u003eProblem 5：Measurement takes too long.\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003ePossible causes: Incorrect ending mode selected\u003c\/p\u003e\n\u003cp class=\"faq\"\u003e\u003cb\u003eProblem 6: Measurements are not repeatable.\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003ePossible causes: The samples are not homogeneous.\/ Drying time is too short.\/ The temp selected is too high and the sample has been oxidized.\/ The temperature sensor is contaminated or defective.\/ The sample is not completely dry.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch2 class=\"section-title3\"\u003eCE Certified Quality \u0026amp; Safety\u003c\/h2\u003e\n\u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/CE\/CE.jpg\"\u003e\n\u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/CE\/CE.jpg\"\u003e\n\u003ch2 class=\"section-title3\"\u003eAll Options\u003c\/h2\u003e\n\u003cdiv class=\"parameters-table-wrapper2\"\u003e\n\u003ctable class=\"parameters-table2\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/ussolid.com\/products\/moisture-analyzer-110g-x-5mg-0-1-readability-halogen-moisture-balance-by-u-s-solid-html\" target=\"_blank\"\u003e\u003cstrong\u003eUSS-HMA01\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/ussolid.com\/products\/moisture-analyzer-110g-x-1mg-0-01-readability-halogen-moisture-balance-by-u-s-solid-html\" target=\"_blank\"\u003e\u003cstrong\u003eUSS-HMA02\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/ussolid.com\/products\/moisture-analyzer-110g-x-1mg-0-01-readability-touch-screen-halogen-moisture-balance-by-u-s-solid-html\" target=\"_blank\"\u003e\u003cstrong\u003eUSS-HMA03\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/ussolid.com\/products\/moisture-analyzer-0-001-g-0-01-readability-moisture-balance-7-inch-touch-screen-html\" target=\"_blank\"\u003e\u003cstrong\u003eUSS-HMA11\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/ussolid.com\/products\/moisture-analyzer-0-001-g-0-01-readability-moisture-balance-7-inch-touch-screen-automatic-door-html\" target=\"_blank\"\u003e\u003cstrong\u003eUSS-HMA12\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/ussolid.com\/products\/moisture-analyzer-0-0001-g-0-001-readability-moisture-balance-7-inch-touch-screen-automatic-door-html\" target=\"_blank\"\u003e\u003cstrong\u003eUSS-HMA13\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eUSS-HMA14\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/ussolid.com\/products\/moisture-analyzer-0-01-g-0-1-readability-moisture-balance-5-inch-touch-screen-110-g-capacity-html\" target=\"_blank\"\u003e\u003cstrong\u003eUSS-HMA21\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/ussolid.com\/products\/moisture-analyzer-0-005-g-0-05-readability-moisture-balance-5-inch-touch-screen-110-g-capacity-html\" target=\"_blank\"\u003e\u003cstrong\u003eUSS-HMA22\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/ussolid.com\/products\/moisture-analyzer-0-001-g-0-01-readability-moisture-balance-5-inch-touch-screen-110-g-capacity-html\" target=\"_blank\"\u003e\u003cstrong\u003eUSS-HMA23\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003ePositioning\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eMainstream\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eHigh-end\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eEconomical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eWeight Readability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.005 g\u003c\/td\u003e\n\u003ctd\u003e0.001 g\u003c\/td\u003e\n\u003ctd\u003e0.001 g\u003c\/td\u003e\n\u003ctd\u003e0.001 g\u003c\/td\u003e\n\u003ctd\u003e0.001 g\u003c\/td\u003e\n\u003ctd\u003e0.0001 g\u003c\/td\u003e\n\u003ctd\u003e0.0001 g\u003c\/td\u003e\n\u003ctd\u003e0.01 g\u003c\/td\u003e\n\u003ctd\u003e0.005 g\u003c\/td\u003e\n\u003ctd\u003e0.001 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eMoisture Readability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 %\u003c\/td\u003e\n\u003ctd\u003e0.01 %\u003c\/td\u003e\n\u003ctd\u003e0.01 %\u003c\/td\u003e\n\u003ctd\u003e0.01 %\u003c\/td\u003e\n\u003ctd\u003e0.01 %\u003c\/td\u003e\n\u003ctd\u003e0.001 %\u003c\/td\u003e\n\u003ctd\u003e0.001 %\u003c\/td\u003e\n\u003ctd\u003e0.1 %\u003c\/td\u003e\n\u003ctd\u003e0.05 %\u003c\/td\u003e\n\u003ctd\u003e0.01 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eWeighing Sensor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eHigh-end strain gauge\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eHigh-end strain gauge\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eElectromagnetic force\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eStrain gauge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eControl Panel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePush Button\u003c\/td\u003e\n\u003ctd\u003ePush Button\u003c\/td\u003e\n\u003ctd\u003e5\" Touch Screen\u003c\/td\u003e\n\u003ctd\u003e7\" Touch Screen\u003c\/td\u003e\n\u003ctd\u003e7\" Touch Screen\u003c\/td\u003e\n\u003ctd\u003e7\" Touch Screen\u003c\/td\u003e\n\u003ctd\u003e7\" Touch Screen\u003c\/td\u003e\n\u003ctd\u003e5\" Touch Screen\u003c\/td\u003e\n\u003ctd\u003e5\" Touch Screen\u003c\/td\u003e\n\u003ctd\u003e5\" Touch Screen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eCalibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eAuto\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eHeater Cover\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eAuto\u003c\/td\u003e\n\u003ctd\u003eAuto\u003c\/td\u003e\n\u003ctd\u003eAuto\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eData Storage Group\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003e200\u003c\/td\u003e\n\u003ctd\u003e200\u003c\/td\u003e\n\u003ctd\u003e200\u003c\/td\u003e\n\u003ctd\u003e200\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e40℃ - 199℃\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e40 ℃ - 200℃\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e40 ℃ - 160℃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eDrying mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eStandard, Fast, Soft\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eStandard, Fast, Soft, Step\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eStandard, Fast, Soft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eEnding mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"10\"\u003eAuto, Timing, Manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003ePan size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eΦ90 mm\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eΦ100 mm\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eΦ100 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"10\"\u003eRS-232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/body\u003e","brand":"U.S. Solid","offers":[{"title":"Default Title","offer_id":46324256178431,"sku":"JFHMA00014","price":2269.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/main-new.jpg?v=1733398309"},{"product_id":"moisture-analyzer-0-0001-g-0-001-readability-moisture-balance-7-inch-touch-screen-automatic-door-html","title":"Moisture Analyzer - 0.0001 g, 0.001% Readability Moisture Balance, 7-inch Touch Screen, Automatic Door","description":"\u003cbody\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003cmeta content=\"width=device-width, initial-scale=1.0\" name=\"viewport\"\u003e\n\u003ctitle\u003eResponsive Page with Multiple Modules\u003c\/title\u003e\n\u003cstyle\u003e\n        \n        .desktop-img {\n            display: block;\n        }\n        .mobile-img {\n            display: none;\n        } \n\n        \n        .section-title {\n            font-size: 22px;\n            line-height: 22px;\n            font-weight: bold;\n            margin: 15px 0 5px; \n            font-family: Arial;\n        }\n        \n        .section-title2 {\n            font-size: 22px;\n            line-height: 22px;\n            font-weight: bold;\n            margin: 15px 0 3px; \n            font-family: Arial;\n        }\n        \n        .section-title3 {\n            font-size: 22px;\n            line-height: 22px;\n            font-weight: bold;\n            margin: 15px 0 10px; \n            font-family: Arial;\n        }\n\n        \n        .section-description {\n            font-size: 16px;\n            line-height: 26px;\n            margin-top: 0px;\n            margin-bottom: 5px; \n            font-family: Arial;\n        }\n        \n        .faq {\n            font-size: 16px; \n            margin: 0; \n            line-height: 26px; \n            background-color: #f2f2f2; \n            padding: 5px;\n        }\n        \n        .section-description2 {\n            font-size: 16px;\n            line-height: 26px;\n            margin: 0px; \n            font-family: Arial;\n        }\n        \n.parameters-table-wrapper {\n    overflow-x: auto; \n    -webkit-overflow-scrolling: touch; \n    margin-top: 0px;\n}\n\n\n.parameters-table {\n    width: 100%;\n    min-width: 1000px; \n    border-collapse: collapse;\n    margin-top: 0px;\n}\n\n.parameters-table th, .parameters-table td {\n    border-top: 1.2px solid #a6a6a6;  \n    border-bottom: 1.2px solid #a6a6a6;  \n    border-left: none;  \n    border-right: none;  \n    padding: 5px 2px;\n    text-align: left;\n    font-size: 16px;\n    line-height: 16px;\n}\n\n.parameters-table th {\n    background-color: #f2f2f2;\n    color: #2c2c2c;\n    font-weight: bold;\n}\n\n\n.parameters-table .bg-gray {\n    background-color: #f2f2f2;  \n}\n\n\n.options-table-wrapper {\n    overflow-x: auto; \n    -webkit-overflow-scrolling: touch; \n    margin-top: 0px;\n}\n\n.options-table {\n    width: 100%;\n    min-width: 1000px; \n    border-collapse: collapse;\n    margin-top: 0px;\n    box-shadow: 0 6px 25px rgba(0, 0, 0, 0.1); \n}\n\n.options-table th, .options-table td {\n    border: 2px solid #000;  \n    padding: 5px 2px;  \n    text-align: center;\n    font-size: 16px;\n    line-height: 16px;\n}\n\n.options-table th {\n    background-color: #f2f2f2;\n    color: #2c2c2c;\n    font-weight: bold;\n}\n\n\n.parameters-table2 {\n    width: 100%;\n    min-width: 1000px; \n    border-collapse: collapse;\n    margin-top: 0px;\n}\n\n.parameters-table2 th, .parameters-table2 td {\n    border-top: 1.2px solid #a6a6a6;  \n    border-bottom: 1.2px solid #a6a6a6;  \n    border-left: none;  \n    border-right: none;  \n    padding: 5px 2px;\n    text-align: center;\n    font-size: 16px;\n    line-height: 16px;\n}\n\n.parameters-table2 th {\n    background-color: #f2f2f2;\n    color: #2c2c2c;\n    font-weight: bold;\n}\n\n\n.parameters-table2 .bg-gray {\n    background-color: #f2f2f2;  \n}\n\n\n.options-table-wrapper2 {\n    overflow-x: auto; \n    -webkit-overflow-scrolling: touch; \n    margin-top: 0px;\n}\n\n\n@media (max-width: 768px) {\n    .parameters-table th, .parameters-table td {\n        font-size: 14px; \n        padding: 8px 4px; \n    }\n\n    \n    .options-table th, .options-table td {\n        font-size: 14px; \n        padding: 8px 4px;\n    }\n\n    .parameters-table-wrapper {\n        overflow-x: auto;\n    }\n    .parameters-table2 th, .parameters-table2 td {\n        font-size: 14px; \n        padding: 8px 4px; \n    }\n    .parameters-table-wrapper2 {\n        overflow-x: auto;\n    }\n    .desktop-img {\n                display: none; \n            }\n            .mobile-img {\n                display: block; \n            }\n    \n}\n\n@media (max-width: 480px) {\n    .parameters-table th, .parameters-table td {\n        font-size: 12px; \n        padding: 6px 3px; \n    }\n\n    \n    .options-table th, .options-table td {\n        font-size: 12px; \n    }\n\n    .parameters-table-wrapper {\n        overflow-x: auto;\n    }\n    .parameters-table2 th, .parameters-table2 td {\n        font-size: 12px; \n        padding: 6px 3px; \n    }\n    .parameters-table-wrapper2 {\n        overflow-x: auto;\n    }\n    .desktop-img {\n                display: none; \n            }\n            .mobile-img {\n                display: block; \n            }\n    \n}\n    \u003c\/style\u003e\n\u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHMA\/jfhma13-background.png\"\u003e\n\u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHMA\/USS-HMA13.png\"\u003e\n\u003cdiv\u003e\n\u003ch2 class=\"section-title\"\u003eIntroduction\u003c\/h2\u003e\n\u003cp class=\"section-description\"\u003e\n            The U.S. Solid USS-HMA13 Moisture Analyzer provides a high level of operating convenience and response sensitivity to facilitate determination of the moisture content of your samples.\u003cbr\u003e\n            It comes with smart functionalities that allows you to preset and store measuring methods, so you can access the options with ease. The device features a 450W halogen lamp and a electromagnetic force transducer that delivers fast and accurate results even on low-moisture samples. USS-HMA13 moisture balance incorporates a high-definition 7-inch LCD color touch-panel that displays with higher accuracy and clarity any test result than general panel. Compact, practical, and easy to use, this moisture balance is a better choice for every lab.\u003cbr\u003eMoisture analyzers work according to the thermogravimetric principle. Moisture is determined by the direct weight lost by the sample due to heating from an intense halogen light.\n        \u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch2 class=\"section-title2\"\u003eApplications\u003c\/h2\u003e\n\u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHMA\/jfhma01-3%281%29.jpg\"\u003e\n\u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHMA\/jfhma-background.jpg\"\u003e\n\u003cdiv\u003e\n\u003ch2 class=\"section-title\"\u003eFeatures\u003c\/h2\u003e\n\u003cul class=\"section-description2\"\u003e\n\u003cli\u003eReadability: 0.0001g (0.1mg)\u003c\/li\u003e\n\u003cli\u003eMoisture readability: 0.001%\u003c\/li\u003e\n\u003cli\u003eManual calibration\u003c\/li\u003e\n\u003cli\u003eElectromagnetic force transducer\u003c\/li\u003e\n\u003cli\u003eAutomatic door mechanism: Features a convenient automatic door that can be operated via touch commands on the screen.\u003c\/li\u003e\n\u003cli\u003e7-inch LCD color touch-panel: Displays real-time testing curve\u003c\/li\u003e\n\u003cli\u003ePrecise temperature control: Adjustable from 40°C to 200°C in 1°C increments\u003c\/li\u003e\n\u003cli\u003eNoise control: Silent fan ensures a quiet testing environment\u003c\/li\u003e\n\u003cli\u003eUser authentication: Allows setting up an admin and multiple operators, each with unique passwords for secure access to testing data.\u003c\/li\u003e\n\u003cli\u003e4 drying modes (standard\/fast\/soft\/step)\u003c\/li\u003e\n\u003cli\u003e3 ending modes (automatic\/manual\/timing)\u003c\/li\u003e\n\u003cli\u003e200 groups of methods can be preset and stored\u003c\/li\u003e\n\u003cli\u003e3 kinds of result display (moisture percentage\/dry weight\/dry-weight percentage)\u003c\/li\u003e\n\u003cli\u003e50 sample pans included\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch2 class=\"section-title\"\u003eMore Details\u003c\/h2\u003e\n\u003cp\u003e\u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHMA\/jfhma14-e-1.jpg\"\u003e \u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHMA\/jfhma14-e-2.jpg\"\u003e \u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHMA\/jfhma13-e-3.jpg\"\u003e \u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHMA\/jfhma14-e-1-p.jpg\"\u003e \u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHMA\/jfhma14-e-2-p.jpg\"\u003e \u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHMA\/jfhma13-e-3-p.jpg\"\u003e\u003c\/p\u003e\n\u003ch2 class=\"section-title\"\u003eUser Manual\u003c\/h2\u003e\n\u003cp class=\"section-description\"\u003e\n            For detailed information on calibration, installation, setup, and usage, please refer to the \u003ca href=\"https:\/\/file.ussolid.com\/content\/JFHMA\/Instruction%20Manual%20-%20USS-HMA1X%20Moisture%20Analyzer.pdf\" target=\"_blank\"\u003euser manual\u003c\/a\u003e or watch the \u003ca href=\"https:\/\/youtu.be\/q50Oz81kwzI?list=TLGG7A8nrVXMxpcwMTA0MjAyNQ\" target=\"_blank\"\u003etutorial video\u003c\/a\u003e.\n    \u003c\/p\u003e\n\u003ch2 class=\"section-title3\"\u003eTechnical Data\u003c\/h2\u003e\n\u003cdiv class=\"parameters-table-wrapper\"\u003e\n\u003ctable class=\"parameters-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSS-HMA13\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eCalibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eCapacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110 g\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eDisplays of results\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e[%m]\/ [%]\/ [g]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eWeight Readability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.0001 g\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eCalibration Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eMoisture Readability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.001 %\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eStabilization Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 3s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eHeating Element\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e450W Halogen Lamp\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003ePan size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/ussolid.com\/products\/50-pack-aluminum-sample-pan-100-mm-for-u-s-solid-moisture-analyzers?_pos=1\u0026amp;_sid=4dab01060\u0026amp;_ss=r\" target=\"_blank\"\u003eΦ100mm\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eOperating temperature range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e104℉-392℉ (40℃-200℃)\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRS-232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eAmbient temperature range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e41℉-95℉ (5℃-35℃)\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eHeater Cover\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAutomatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eTime setting range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 - 99 min\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003ePower\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110V 60Hz AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eDrying mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard\/ Fast\/ Soft\/ Step\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eProduct dimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.8*16.1*7.1 inches(200*410*180 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eEnding mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAuto\/ Timing\/ Manual\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15.65 lbs (7.1 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ch2 class=\"section-title\"\u003eTroubleshooting\u003c\/h2\u003e\n\u003cp class=\"faq\"\u003e\u003cb\u003eProblem 1: Display remains off after switching on.\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003ePossible causes: Power cord is not connected\/ Power line fuse blown\/ Power supply interrupted\/ Instrument faulty\u003c\/p\u003e\n\u003cp class=\"faq\"\u003e\u003cb\u003eProblem 2: Display does not change when loading samples.\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003ePossible causes: The sample pan\/pan holder is not installed correctly.\u003c\/p\u003e\n\u003cp class=\"faq\"\u003e\u003cb\u003eProblem 3: Weight display is constantly changing or unstable.\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003ePossible causes: The sample pan is in contact with the draft shield or heating chamber\/ Air movement\/ Test bench vibration\/ Electromagnetic field interference\u003c\/p\u003e\n\u003cp class=\"faq\"\u003e\u003cb\u003eProblem 4: Drying does not start.\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003ePossible causes: Heating chamber open\/ Power cord is not connected\/ Power line fuse blown\u003c\/p\u003e\n\u003cp class=\"faq\"\u003e\u003cb\u003eProblem 5：Measurement takes too long.\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003ePossible causes: Incorrect ending mode selected\u003c\/p\u003e\n\u003cp class=\"faq\"\u003e\u003cb\u003eProblem 6: Measurements are not repeatable.\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003ePossible causes: The samples are not homogeneous.\/ Drying time is too short.\/ The temp selected is too high and the sample has been oxidized.\/ The temperature sensor is contaminated or defective.\/ The sample is not completely dry.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch2 class=\"section-title3\"\u003eCE Certified Quality \u0026amp; Safety\u003c\/h2\u003e\n\u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/CE\/CE.jpg\"\u003e\n\u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/CE\/CE.jpg\"\u003e\n\u003ch2 class=\"section-title3\"\u003eAll Options\u003c\/h2\u003e\n\u003cdiv class=\"parameters-table-wrapper2\"\u003e\n\u003ctable class=\"parameters-table2\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/ussolid.com\/products\/moisture-analyzer-110g-x-5mg-0-1-readability-halogen-moisture-balance-by-u-s-solid-html\" target=\"_blank\"\u003e\u003cstrong\u003eUSS-HMA01\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/ussolid.com\/products\/moisture-analyzer-110g-x-1mg-0-01-readability-halogen-moisture-balance-by-u-s-solid-html\" target=\"_blank\"\u003e\u003cstrong\u003eUSS-HMA02\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/ussolid.com\/products\/moisture-analyzer-110g-x-1mg-0-01-readability-touch-screen-halogen-moisture-balance-by-u-s-solid-html\" target=\"_blank\"\u003e\u003cstrong\u003eUSS-HMA03\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/ussolid.com\/products\/moisture-analyzer-0-001-g-0-01-readability-moisture-balance-7-inch-touch-screen-html\" target=\"_blank\"\u003e\u003cstrong\u003eUSS-HMA11\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/ussolid.com\/products\/moisture-analyzer-0-001-g-0-01-readability-moisture-balance-7-inch-touch-screen-automatic-door-html\" target=\"_blank\"\u003e\u003cstrong\u003eUSS-HMA12\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eUSS-HMA13\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/ussolid.com\/products\/moisture-analyzer-0-0001-g-0-001-readability-moisture-balance-7-inch-touch-screen-internal-calibration-and-automatic-door-html\" target=\"_blank\"\u003e\u003cstrong\u003eUSS-HMA14\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/ussolid.com\/products\/moisture-analyzer-0-01-g-0-1-readability-moisture-balance-5-inch-touch-screen-110-g-capacity-html\" target=\"_blank\"\u003e\u003cstrong\u003eUSS-HMA21\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/ussolid.com\/products\/moisture-analyzer-0-005-g-0-05-readability-moisture-balance-5-inch-touch-screen-110-g-capacity-html\" target=\"_blank\"\u003e\u003cstrong\u003eUSS-HMA22\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/ussolid.com\/products\/moisture-analyzer-0-001-g-0-01-readability-moisture-balance-5-inch-touch-screen-110-g-capacity-html\" target=\"_blank\"\u003e\u003cstrong\u003eUSS-HMA23\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003ePositioning\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eMainstream\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eHigh-end\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eEconomical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eWeight Readability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.005 g\u003c\/td\u003e\n\u003ctd\u003e0.001 g\u003c\/td\u003e\n\u003ctd\u003e0.001 g\u003c\/td\u003e\n\u003ctd\u003e0.001 g\u003c\/td\u003e\n\u003ctd\u003e0.001 g\u003c\/td\u003e\n\u003ctd\u003e0.0001 g\u003c\/td\u003e\n\u003ctd\u003e0.0001 g\u003c\/td\u003e\n\u003ctd\u003e0.01 g\u003c\/td\u003e\n\u003ctd\u003e0.005 g\u003c\/td\u003e\n\u003ctd\u003e0.001 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eMoisture Readability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 %\u003c\/td\u003e\n\u003ctd\u003e0.01 %\u003c\/td\u003e\n\u003ctd\u003e0.01 %\u003c\/td\u003e\n\u003ctd\u003e0.01 %\u003c\/td\u003e\n\u003ctd\u003e0.01 %\u003c\/td\u003e\n\u003ctd\u003e0.001 %\u003c\/td\u003e\n\u003ctd\u003e0.001 %\u003c\/td\u003e\n\u003ctd\u003e0.1 %\u003c\/td\u003e\n\u003ctd\u003e0.05 %\u003c\/td\u003e\n\u003ctd\u003e0.01 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eWeighing Sensor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eHigh-end strain gauge\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eHigh-end strain gauge\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eElectromagnetic force\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eStrain gauge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eControl Panel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePush Button\u003c\/td\u003e\n\u003ctd\u003ePush Button\u003c\/td\u003e\n\u003ctd\u003e5\" Touch Screen\u003c\/td\u003e\n\u003ctd\u003e7\" Touch Screen\u003c\/td\u003e\n\u003ctd\u003e7\" Touch Screen\u003c\/td\u003e\n\u003ctd\u003e7\" Touch Screen\u003c\/td\u003e\n\u003ctd\u003e7\" Touch Screen\u003c\/td\u003e\n\u003ctd\u003e5\" Touch Screen\u003c\/td\u003e\n\u003ctd\u003e5\" Touch Screen\u003c\/td\u003e\n\u003ctd\u003e5\" Touch Screen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eCalibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eAuto\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eHeater Cover\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eAuto\u003c\/td\u003e\n\u003ctd\u003eAuto\u003c\/td\u003e\n\u003ctd\u003eAuto\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eData Storage Group\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003e200\u003c\/td\u003e\n\u003ctd\u003e200\u003c\/td\u003e\n\u003ctd\u003e200\u003c\/td\u003e\n\u003ctd\u003e200\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e40℃ - 199℃\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e40 ℃ - 200℃\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e40 ℃ - 160℃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eDrying mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eStandard, Fast, Soft\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eStandard, Fast, Soft, Step\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eStandard, Fast, Soft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eEnding mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"10\"\u003eAuto, Timing, Manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003ePan size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eΦ90 mm\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eΦ100 mm\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eΦ100 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"10\"\u003eRS-232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/body\u003e","brand":"U.S. Solid","offers":[{"title":"Default Title","offer_id":46324256211199,"sku":"JFHMA00013","price":2147.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/main-new.jpg?v=1733398309"},{"product_id":"moisture-analyzer-0-001-g-0-01-readability-moisture-balance-7-inch-touch-screen-automatic-door-html","title":"Moisture Analyzer - 0.001 g, 0.01% Readability Moisture Balance, 7-inch Touch Screen, Automatic Door","description":"\u003cbody\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003cmeta content=\"width=device-width, initial-scale=1.0\" name=\"viewport\"\u003e\n\u003ctitle\u003eResponsive Page with Multiple Modules\u003c\/title\u003e\n\u003cstyle\u003e\n        \n        .desktop-img {\n            display: block;\n        }\n        .mobile-img {\n            display: none;\n        } \n\n        \n        .section-title {\n            font-size: 22px;\n            line-height: 22px;\n            font-weight: bold;\n            margin: 15px 0 5px; \n            font-family: Arial;\n        }\n        \n        .section-title2 {\n            font-size: 22px;\n            line-height: 22px;\n            font-weight: bold;\n            margin: 15px 0 3px; \n            font-family: Arial;\n        }\n        \n        .section-title3 {\n            font-size: 22px;\n            line-height: 22px;\n            font-weight: bold;\n            margin: 15px 0 10px; \n            font-family: Arial;\n        }\n\n        \n        .section-description {\n            font-size: 16px;\n            line-height: 26px;\n            margin-top: 0px;\n            margin-bottom: 5px; \n            font-family: Arial;\n        }\n        \n        .faq {\n            font-size: 16px; \n            margin: 0; \n            line-height: 26px; \n            background-color: #f2f2f2; \n            padding: 5px;\n        }\n        \n        .section-description2 {\n            font-size: 16px;\n            line-height: 26px;\n            margin: 0px; \n            font-family: Arial;\n        }\n        \n.parameters-table-wrapper {\n    overflow-x: auto; \n    -webkit-overflow-scrolling: touch; \n    margin-top: 0px;\n}\n\n\n.parameters-table {\n    width: 100%;\n    min-width: 1000px; \n    border-collapse: collapse;\n    margin-top: 0px;\n}\n\n.parameters-table th, .parameters-table td {\n    border-top: 1.2px solid #a6a6a6;  \n    border-bottom: 1.2px solid #a6a6a6;  \n    border-left: none;  \n    border-right: none;  \n    padding: 5px 2px;\n    text-align: left;\n    font-size: 16px;\n    line-height: 16px;\n}\n\n.parameters-table th {\n    background-color: #f2f2f2;\n    color: #2c2c2c;\n    font-weight: bold;\n}\n\n\n.parameters-table .bg-gray {\n    background-color: #f2f2f2;  \n}\n\n\n.options-table-wrapper {\n    overflow-x: auto; \n    -webkit-overflow-scrolling: touch; \n    margin-top: 0px;\n}\n\n.options-table {\n    width: 100%;\n    min-width: 1000px; \n    border-collapse: collapse;\n    margin-top: 0px;\n    box-shadow: 0 6px 25px rgba(0, 0, 0, 0.1); \n}\n\n.options-table th, .options-table td {\n    border: 2px solid #000;  \n    padding: 5px 2px;  \n    text-align: center;\n    font-size: 16px;\n    line-height: 16px;\n}\n\n.options-table th {\n    background-color: #f2f2f2;\n    color: #2c2c2c;\n    font-weight: bold;\n}\n\n\n.parameters-table2 {\n    width: 100%;\n    min-width: 1000px; \n    border-collapse: collapse;\n    margin-top: 0px;\n}\n\n.parameters-table2 th, .parameters-table2 td {\n    border-top: 1.2px solid #a6a6a6;  \n    border-bottom: 1.2px solid #a6a6a6;  \n    border-left: none;  \n    border-right: none;  \n    padding: 5px 2px;\n    text-align: center;\n    font-size: 16px;\n    line-height: 16px;\n}\n\n.parameters-table2 th {\n    background-color: #f2f2f2;\n    color: #2c2c2c;\n    font-weight: bold;\n}\n\n\n.parameters-table2 .bg-gray {\n    background-color: #f2f2f2;  \n}\n\n\n.options-table-wrapper2 {\n    overflow-x: auto; \n    -webkit-overflow-scrolling: touch; \n    margin-top: 0px;\n}\n\n\n@media (max-width: 768px) {\n    .parameters-table th, .parameters-table td {\n        font-size: 14px; \n        padding: 8px 4px; \n    }\n\n    \n    .options-table th, .options-table td {\n        font-size: 14px; \n        padding: 8px 4px;\n    }\n\n    .parameters-table-wrapper {\n        overflow-x: auto;\n    }\n    .parameters-table2 th, .parameters-table2 td {\n        font-size: 14px; \n        padding: 8px 4px; \n    }\n    .parameters-table-wrapper2 {\n        overflow-x: auto;\n    }\n    .desktop-img {\n                display: none; \n            }\n            .mobile-img {\n                display: block; \n            }\n    \n}\n\n@media (max-width: 480px) {\n    .parameters-table th, .parameters-table td {\n        font-size: 12px; \n        padding: 6px 3px; \n    }\n\n    \n    .options-table th, .options-table td {\n        font-size: 12px; \n    }\n\n    .parameters-table-wrapper {\n        overflow-x: auto;\n    }\n    .parameters-table2 th, .parameters-table2 td {\n        font-size: 12px; \n        padding: 6px 3px; \n    }\n    .parameters-table-wrapper2 {\n        overflow-x: auto;\n    }\n    .desktop-img {\n                display: none; \n            }\n            .mobile-img {\n                display: block; \n            }\n    \n}\n    \u003c\/style\u003e\n\u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHMA\/jfhma12-background.png\"\u003e\n\u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHMA\/USS-HMA12.png\"\u003e\n\u003cdiv\u003e\n\u003ch2 class=\"section-title\"\u003eIntroduction\u003c\/h2\u003e\n\u003cp class=\"section-description\"\u003e\n            The U.S. Solid USS-HMA12 Moisture Analyzer provides a high level of operating convenience and response sensitivity to facilitate determination of the moisture content of your samples.\u003cbr\u003e\n            It comes with smart functionalities that allows you to preset and store measuring methods, so you can access the options with ease. The device features a 450W halogen lamp and a premium transducer that delivers fast and accurate results even on low-moisture samples. USS-HMA12 moisture balance incorporates a high-definition 7-inch LCD color touch-panel that displays with higher accuracy and clarity any test result than general panel. Compact, practical, and easy to use, this moisture balance is a better choice for every lab.\u003cbr\u003eMoisture analyzers work according to the thermogravimetric principle. Moisture is determined by the direct weight lost by the sample due to heating from an intense halogen light.\n        \u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch2 class=\"section-title2\"\u003eApplications\u003c\/h2\u003e\n\u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHMA\/jfhma01-3%281%29.jpg\"\u003e\n\u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHMA\/jfhma-background.jpg\"\u003e\n\u003cdiv\u003e\n\u003ch2 class=\"section-title\"\u003eFeatures\u003c\/h2\u003e\n\u003cul class=\"section-description2\"\u003e\n\u003cli\u003eReadability: 0.001g (1mg)\u003c\/li\u003e\n\u003cli\u003eMoisture readability: 0.01%\u003c\/li\u003e\n\u003cli\u003eManual calibration\u003c\/li\u003e\n\u003cli\u003eWeighing sensor: High-end strain gauge\u003c\/li\u003e\n\u003cli\u003eAutomatic door mechanism: Features a convenient automatic door that can be operated via touch commands on the screen.\u003c\/li\u003e\n\u003cli\u003e7-inch LCD color touch-panel: Displays real-time testing curve\u003c\/li\u003e\n\u003cli\u003ePrecise temperature control: Adjustable from 40°C to 200°C in 1°C increments\u003c\/li\u003e\n\u003cli\u003eNoise control: Silent fan ensures a quiet testing environment\u003c\/li\u003e\n\u003cli\u003eUser authentication: Allows setting up an admin and multiple operators, each with unique passwords for secure access to testing data.\u003c\/li\u003e\n\u003cli\u003e4 drying modes (standard\/fast\/soft\/step)\u003c\/li\u003e\n\u003cli\u003e3 ending modes (automatic\/manual\/timing)\u003c\/li\u003e\n\u003cli\u003e200 groups of methods can be preset and stored\u003c\/li\u003e\n\u003cli\u003e3 kinds of result display (moisture percentage\/dry weight\/dry-weight percentage)\u003c\/li\u003e\n\u003cli\u003e50 sample pans included\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch2 class=\"section-title\"\u003eMore Details\u003c\/h2\u003e\n\u003cp\u003e\u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHMA\/jfhma12-e-1.jpg\"\u003e \u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHMA\/jfhma14-e-2.jpg\"\u003e \u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHMA\/jfhma12-e-3.jpg\"\u003e \u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHMA\/jfhma12-e-1-p.jpg\"\u003e \u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHMA\/jfhma14-e-2-p.jpg\"\u003e \u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHMA\/jfhma12-e-3-p.jpg\"\u003e\u003c\/p\u003e\n\u003ch2 class=\"section-title\"\u003eUser Manual\u003c\/h2\u003e\n\u003cp class=\"section-description\"\u003e\n            For detailed information on calibration, installation, setup, and usage, please refer to the \u003ca href=\"https:\/\/file.ussolid.com\/content\/JFHMA\/Instruction%20Manual%20-%20USS-HMA1X%20Moisture%20Analyzer.pdf\" target=\"_blank\"\u003euser manual\u003c\/a\u003e or watch the \u003ca href=\"https:\/\/youtu.be\/q50Oz81kwzI?list=TLGG7A8nrVXMxpcwMTA0MjAyNQ\" target=\"_blank\"\u003etutorial video\u003c\/a\u003e.\n    \u003c\/p\u003e\n\u003ch2 class=\"section-title3\"\u003eTechnical Data\u003c\/h2\u003e\n\u003cdiv class=\"parameters-table-wrapper\"\u003e\n\u003ctable class=\"parameters-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSS-HMA12\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eCalibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eCapacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110 g\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eDisplays of results\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e[%m]\/ [%]\/ [g]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eWeight Readability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.001 g\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eCalibration Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eMoisture Readability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01%\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eStabilization Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 3s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eHeating Element\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e450W Halogen Lamp\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003ePan size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/ussolid.com\/products\/50-pack-aluminum-sample-pan-100-mm-for-u-s-solid-moisture-analyzers?_pos=1\u0026amp;_sid=4dab01060\u0026amp;_ss=r\" target=\"_blank\"\u003eΦ100mm\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eOperating temperature range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e104℉-392℉ (40℃-200℃)\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRS-232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eAmbient temperature range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e41℉-95℉ (5℃-35℃)\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eHeater Cover\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAutomatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eTime setting range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 - 99 min\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003ePower\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110V 60Hz AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eDrying mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard\/ Fast\/ Soft\/ Step\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eProduct dimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.5*16.6*6.3 inches(190*420*160 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eEnding mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAuto\/ Timing\/ Manual\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16.78 lbs (7.61 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ch2 class=\"section-title\"\u003eTroubleshooting\u003c\/h2\u003e\n\u003cp class=\"faq\"\u003e\u003cb\u003eProblem 1: Display remains off after switching on.\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003ePossible causes: Power cord is not connected\/ Power line fuse blown\/ Power supply interrupted\/ Instrument faulty\u003c\/p\u003e\n\u003cp class=\"faq\"\u003e\u003cb\u003eProblem 2: Display does not change when loading samples.\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003ePossible causes: The sample pan\/pan holder is not installed correctly.\u003c\/p\u003e\n\u003cp class=\"faq\"\u003e\u003cb\u003eProblem 3: Weight display is constantly changing or unstable.\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003ePossible causes: The sample pan is in contact with the draft shield or heating chamber\/ Air movement\/ Test bench vibration\/ Electromagnetic field interference\u003c\/p\u003e\n\u003cp class=\"faq\"\u003e\u003cb\u003eProblem 4: Drying does not start.\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003ePossible causes: Heating chamber open\/ Power cord is not connected\/ Power line fuse blown\u003c\/p\u003e\n\u003cp class=\"faq\"\u003e\u003cb\u003eProblem 5：Measurement takes too long.\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003ePossible causes: Incorrect ending mode selected\u003c\/p\u003e\n\u003cp class=\"faq\"\u003e\u003cb\u003eProblem 6: Measurements are not repeatable.\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003ePossible causes: The samples are not homogeneous.\/ Drying time is too short.\/ The temp selected is too high and the sample has been oxidized.\/ The temperature sensor is contaminated or defective.\/ The sample is not completely dry.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch2 class=\"section-title3\"\u003eCE Certified Quality \u0026amp; Safety\u003c\/h2\u003e\n\u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/CE\/CE.jpg\"\u003e\n\u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/CE\/CE.jpg\"\u003e\n\u003ch2 class=\"section-title3\"\u003eAll Options\u003c\/h2\u003e\n\u003cdiv class=\"parameters-table-wrapper2\"\u003e\n\u003ctable class=\"parameters-table2\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/ussolid.com\/products\/moisture-analyzer-110g-x-5mg-0-1-readability-halogen-moisture-balance-by-u-s-solid-html\" target=\"_blank\"\u003e\u003cstrong\u003eUSS-HMA01\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/ussolid.com\/products\/moisture-analyzer-110g-x-1mg-0-01-readability-halogen-moisture-balance-by-u-s-solid-html\" target=\"_blank\"\u003e\u003cstrong\u003eUSS-HMA02\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/ussolid.com\/products\/moisture-analyzer-110g-x-1mg-0-01-readability-touch-screen-halogen-moisture-balance-by-u-s-solid-html\" target=\"_blank\"\u003e\u003cstrong\u003eUSS-HMA03\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/ussolid.com\/products\/moisture-analyzer-0-001-g-0-01-readability-moisture-balance-7-inch-touch-screen-html\" target=\"_blank\"\u003e\u003cstrong\u003eUSS-HMA11\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eUSS-HMA12\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/ussolid.com\/products\/moisture-analyzer-0-0001-g-0-001-readability-moisture-balance-7-inch-touch-screen-automatic-door-html\" target=\"_blank\"\u003e\u003cstrong\u003eUSS-HMA13\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/ussolid.com\/products\/moisture-analyzer-0-0001-g-0-001-readability-moisture-balance-7-inch-touch-screen-internal-calibration-and-automatic-door-html\" target=\"_blank\"\u003e\u003cstrong\u003eUSS-HMA14\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/ussolid.com\/products\/moisture-analyzer-0-01-g-0-1-readability-moisture-balance-5-inch-touch-screen-110-g-capacity-html\" target=\"_blank\"\u003e\u003cstrong\u003eUSS-HMA21\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/ussolid.com\/products\/moisture-analyzer-0-005-g-0-05-readability-moisture-balance-5-inch-touch-screen-110-g-capacity-html\" target=\"_blank\"\u003e\u003cstrong\u003eUSS-HMA22\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/ussolid.com\/products\/moisture-analyzer-0-001-g-0-01-readability-moisture-balance-5-inch-touch-screen-110-g-capacity-html\" target=\"_blank\"\u003e\u003cstrong\u003eUSS-HMA23\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003ePositioning\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eMainstream\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eHigh-end\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eEconomical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eWeight Readability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.005 g\u003c\/td\u003e\n\u003ctd\u003e0.001 g\u003c\/td\u003e\n\u003ctd\u003e0.001 g\u003c\/td\u003e\n\u003ctd\u003e0.001 g\u003c\/td\u003e\n\u003ctd\u003e0.001 g\u003c\/td\u003e\n\u003ctd\u003e0.0001 g\u003c\/td\u003e\n\u003ctd\u003e0.0001 g\u003c\/td\u003e\n\u003ctd\u003e0.01 g\u003c\/td\u003e\n\u003ctd\u003e0.005 g\u003c\/td\u003e\n\u003ctd\u003e0.001 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eMoisture Readability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 %\u003c\/td\u003e\n\u003ctd\u003e0.01 %\u003c\/td\u003e\n\u003ctd\u003e0.01 %\u003c\/td\u003e\n\u003ctd\u003e0.01 %\u003c\/td\u003e\n\u003ctd\u003e0.01 %\u003c\/td\u003e\n\u003ctd\u003e0.001 %\u003c\/td\u003e\n\u003ctd\u003e0.001 %\u003c\/td\u003e\n\u003ctd\u003e0.1 %\u003c\/td\u003e\n\u003ctd\u003e0.05 %\u003c\/td\u003e\n\u003ctd\u003e0.01 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eWeighing Sensor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eHigh-end strain gauge\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eHigh-end strain gauge\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eElectromagnetic force\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eStrain gauge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eControl Panel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePush Button\u003c\/td\u003e\n\u003ctd\u003ePush Button\u003c\/td\u003e\n\u003ctd\u003e5\" Touch Screen\u003c\/td\u003e\n\u003ctd\u003e7\" Touch Screen\u003c\/td\u003e\n\u003ctd\u003e7\" Touch Screen\u003c\/td\u003e\n\u003ctd\u003e7\" Touch Screen\u003c\/td\u003e\n\u003ctd\u003e7\" Touch Screen\u003c\/td\u003e\n\u003ctd\u003e5\" Touch Screen\u003c\/td\u003e\n\u003ctd\u003e5\" Touch Screen\u003c\/td\u003e\n\u003ctd\u003e5\" Touch Screen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eCalibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eAuto\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eHeater Cover\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eAuto\u003c\/td\u003e\n\u003ctd\u003eAuto\u003c\/td\u003e\n\u003ctd\u003eAuto\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eData Storage Group\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003e200\u003c\/td\u003e\n\u003ctd\u003e200\u003c\/td\u003e\n\u003ctd\u003e200\u003c\/td\u003e\n\u003ctd\u003e200\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e40℃ - 199℃\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e40 ℃ - 200℃\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e40 ℃ - 160℃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eDrying mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eStandard, Fast, Soft\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eStandard, Fast, Soft, Step\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eStandard, Fast, Soft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eEnding mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"10\"\u003eAuto, Timing, Manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003ePan size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eΦ90 mm\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eΦ100 mm\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eΦ100 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"10\"\u003eRS-232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/body\u003e","brand":"U.S. Solid","offers":[{"title":"Default Title","offer_id":46324256473343,"sku":"JFHMA00012","price":1647.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/main-new.jpg?v=1733398309"},{"product_id":"moisture-analyzer-0-001-g-0-01-readability-moisture-balance-5-inch-touch-screen-110-g-capacity-html","title":"Moisture Analyzer - 0.001 g, 0.01% Readability Moisture Balance, 5-inch Touch Screen, 110 g Capacity","description":"\u003cbody\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003cmeta content=\"width=device-width, initial-scale=1.0\" name=\"viewport\"\u003e\n\u003ctitle\u003eResponsive Page with Multiple Modules\u003c\/title\u003e\n\u003cstyle\u003e\n        \n        .desktop-img {\n            display: block;\n        }\n        .mobile-img {\n            display: none;\n        } \n\n        \n        .section-title {\n            font-size: 22px;\n            line-height: 22px;\n            font-weight: bold;\n            margin: 15px 0 5px; \n            font-family: Arial;\n        }\n        \n        .section-title2 {\n            font-size: 22px;\n            line-height: 22px;\n            font-weight: bold;\n            margin: 15px 0 3px; \n            font-family: Arial;\n        }\n        \n        .section-title3 {\n            font-size: 22px;\n            line-height: 22px;\n            font-weight: bold;\n            margin: 15px 0 10px; \n            font-family: Arial;\n        }\n\n        \n        .section-description {\n            font-size: 16px;\n            line-height: 26px;\n            margin-top: 0px;\n            margin-bottom: 5px; \n            font-family: Arial;\n        }\n        \n        .faq {\n            font-size: 16px; \n            margin: 0; \n            line-height: 26px; \n            background-color: #f2f2f2; \n            padding: 5px;\n        }\n        \n        .section-description2 {\n            font-size: 16px;\n            line-height: 26px;\n            margin: 0px; \n            font-family: Arial;\n        }\n        \n.parameters-table-wrapper {\n    overflow-x: auto; \n    -webkit-overflow-scrolling: touch; \n    margin-top: 0px;\n}\n\n\n.parameters-table {\n    width: 100%;\n    min-width: 1000px; \n    border-collapse: collapse;\n    margin-top: 0px;\n}\n\n.parameters-table th, .parameters-table td {\n    border-top: 1.2px solid #a6a6a6;  \n    border-bottom: 1.2px solid #a6a6a6;  \n    border-left: none;  \n    border-right: none;  \n    padding: 5px 2px;\n    text-align: left;\n    font-size: 16px;\n    line-height: 16px;\n}\n\n.parameters-table th {\n    background-color: #f2f2f2;\n    color: #2c2c2c;\n    font-weight: bold;\n}\n\n\n.parameters-table .bg-gray {\n    background-color: #f2f2f2;  \n}\n\n\n.options-table-wrapper {\n    overflow-x: auto; \n    -webkit-overflow-scrolling: touch; \n    margin-top: 0px;\n}\n\n.options-table {\n    width: 100%;\n    min-width: 1000px; \n    border-collapse: collapse;\n    margin-top: 0px;\n    box-shadow: 0 6px 25px rgba(0, 0, 0, 0.1); \n}\n\n.options-table th, .options-table td {\n    border: 2px solid #000;  \n    padding: 5px 2px;  \n    text-align: center;\n    font-size: 16px;\n    line-height: 16px;\n}\n\n.options-table th {\n    background-color: #f2f2f2;\n    color: #2c2c2c;\n    font-weight: bold;\n}\n\n\n.parameters-table2 {\n    width: 100%;\n    min-width: 1000px; \n    border-collapse: collapse;\n    margin-top: 0px;\n}\n\n.parameters-table2 th, .parameters-table2 td {\n    border-top: 1.2px solid #a6a6a6;  \n    border-bottom: 1.2px solid #a6a6a6;  \n    border-left: none;  \n    border-right: none;  \n    padding: 5px 2px;\n    text-align: center;\n    font-size: 16px;\n    line-height: 16px;\n}\n\n.parameters-table2 th {\n    background-color: #f2f2f2;\n    color: #2c2c2c;\n    font-weight: bold;\n}\n\n\n.parameters-table2 .bg-gray {\n    background-color: #f2f2f2;  \n}\n\n\n.options-table-wrapper2 {\n    overflow-x: auto; \n    -webkit-overflow-scrolling: touch; \n    margin-top: 0px;\n}\n\n\n@media (max-width: 768px) {\n    .parameters-table th, .parameters-table td {\n        font-size: 14px; \n        padding: 8px 4px; \n    }\n\n    \n    .options-table th, .options-table td {\n        font-size: 14px; \n        padding: 8px 4px;\n    }\n\n    .parameters-table-wrapper {\n        overflow-x: auto;\n    }\n    .parameters-table2 th, .parameters-table2 td {\n        font-size: 14px; \n        padding: 8px 4px; \n    }\n    .parameters-table-wrapper2 {\n        overflow-x: auto;\n    }\n    .desktop-img {\n                display: none; \n            }\n            .mobile-img {\n                display: block; \n            }\n    \n}\n\n@media (max-width: 480px) {\n    .parameters-table th, .parameters-table td {\n        font-size: 12px; \n        padding: 6px 3px; \n    }\n\n    \n    .options-table th, .options-table td {\n        font-size: 12px; \n    }\n\n    .parameters-table-wrapper {\n        overflow-x: auto;\n    }\n    .parameters-table2 th, .parameters-table2 td {\n        font-size: 12px; \n        padding: 6px 3px; \n    }\n    .parameters-table-wrapper2 {\n        overflow-x: auto;\n    }\n    .desktop-img {\n                display: none; \n            }\n            .mobile-img {\n                display: block; \n            }\n    \n}\n    \u003c\/style\u003e\n\u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHMA\/jfhma23-background.png\"\u003e\n\u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHMA\/USS-HMA23.png\"\u003e\n\u003cdiv\u003e\n\u003ch2 class=\"section-title\"\u003eIntroduction\u003c\/h2\u003e\n\u003cp class=\"section-description\"\u003e\n            The U.S. Solid USS-HMA23 Moisture Analyzer provides a high level of operating convenience and response sensitivity to facilitate determination of the moisture content of your samples.\u003cbr\u003e\n            It comes with smart functionalities that allows you to preset and store measuring methods, so you can access the options with ease. The device is equipped with a 250W halogen lamp and a strain gauge weighing sensor. As an economical model, it effectively meets basic usage needs. USS-HMA23 moisture balance incorporates a 5-inch LCD color touch-panel that displays with higher accuracy and clarity any test result than general panel. Compact, practical, and easy to use, this moisture balance is a better choice for every lab.\u003cbr\u003eMoisture analyzers work according to the thermogravimetric principle. Moisture is determined by the direct weight lost by the sample due to heating from an intense halogen light.\n        \u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch2 class=\"section-title2\"\u003eApplications\u003c\/h2\u003e\n\u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHMA\/jfhma01-3%281%29.jpg\"\u003e\n\u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHMA\/jfhma-background.jpg\"\u003e\n\u003cdiv\u003e\n\u003ch2 class=\"section-title\"\u003eFeatures\u003c\/h2\u003e\n\u003cul class=\"section-description2\"\u003e\n\u003cli\u003eReadability: 0.001g\u003c\/li\u003e\n\u003cli\u003eMoisture readability: 0.01%\u003c\/li\u003e\n\u003cli\u003eManual calibration\u003c\/li\u003e\n\u003cli\u003eWeighing sensor: Strain gauge\u003c\/li\u003e\n\u003cli\u003e5-inch LCD color touch-panel: Displays real-time testing curve\u003c\/li\u003e\n\u003cli\u003eEfficient preheat function: The moisture balance is equipped with an advanced preheat function that significantly expedites the heating process.\u003c\/li\u003e\n\u003cli\u003e3 drying modes (standard\/fast\/soft)\u003c\/li\u003e\n\u003cli\u003e3 ending modes (automatic\/manual\/timing)\u003c\/li\u003e\n\u003cli\u003e20 groups of methods can be preset and stored\u003c\/li\u003e\n\u003cli\u003e3 kinds of result display (moisture percentage\/dry weight\/dry-weight percentage)\u003c\/li\u003e\n\u003cli\u003e20 sample pans included\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch2 class=\"section-title\"\u003eMore Details\u003c\/h2\u003e\n\u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHMA\/jfhma21.jpg\"\u003e\n\u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHMA\/jfhma21-22-23-p-2.png\"\u003e\n\u003ch2 class=\"section-title\"\u003eUser Manual\u003c\/h2\u003e\n\u003cp class=\"section-description\"\u003e\n            For detailed information on calibration, installation, setup, and usage, please refer to the \u003ca href=\"https:\/\/file.ussolid.com\/content\/JFHMA\/Instruction%20Manual%20-%20USS-HMA2X%20Moisture%20Analyzer.pdf\" target=\"_blank\"\u003euser manual\u003c\/a\u003e and watch the \u003ca href=\"https:\/\/www.youtube.com\/watch?v=hKKFibpT3kg\" target=\"_blank\"\u003etutorial video\u003c\/a\u003e.\n    \u003c\/p\u003e\n\u003ch2 class=\"section-title3\"\u003eTechnical Data\u003c\/h2\u003e\n\u003cdiv class=\"parameters-table-wrapper\"\u003e\n\u003ctable class=\"parameters-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSS-HMA23\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eCalibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eCapacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110 g\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eDisplays of results\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e[%m]\/ [%]\/ [g]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eWeight Readability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.001 g\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eCalibration Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eMoisture Readability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01 %\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eStabilization Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 3s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eHeating Element\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250W Halogen Lamp\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003ePan size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/ussolid.com\/products\/50-pack-aluminum-sample-pan-100-mm-for-u-s-solid-moisture-analyzers?_pos=1\u0026amp;_sid=4dab01060\u0026amp;_ss=r\" target=\"_blank\"\u003eΦ100mm\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eOperating temperature range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e104℉-320℉ (40℃-160℃)\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRS-232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eAmbient temperature range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e41℉-95℉ (5℃-35℃)\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eHeater Cover\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eTime setting range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 - 99 min\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003ePower\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110V 60Hz AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eDrying mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard\/ Fast\/ Soft\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eProduct dimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.5*13.6*6.7 inches(190*345*170 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eEnding mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAuto\/ Timing\/ Manual\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6.57 lbs (2.98 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ch2 class=\"section-title\"\u003eTroubleshooting\u003c\/h2\u003e\n\u003cp class=\"faq\"\u003e\u003cb\u003eProblem 1: Display remains off after switching on.\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003ePossible causes: Power cord is not connected\/ Power line fuse blown\/ Power supply interrupted\/ Instrument faulty\u003c\/p\u003e\n\u003cp class=\"faq\"\u003e\u003cb\u003eProblem 2: Display does not change when loading samples.\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003ePossible causes: The sample pan\/pan holder is not installed correctly.\u003c\/p\u003e\n\u003cp class=\"faq\"\u003e\u003cb\u003eProblem 3: Weight display is constantly changing or unstable.\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003ePossible causes: The sample pan is in contact with the draft shield or heating chamber\/ Air movement\/ Test bench vibration\/ Electromagnetic field interference\u003c\/p\u003e\n\u003cp class=\"faq\"\u003e\u003cb\u003eProblem 4: Drying does not start.\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003ePossible causes: Heating chamber open\/ Power cord is not connected\/ Power line fuse blown\u003c\/p\u003e\n\u003cp class=\"faq\"\u003e\u003cb\u003eProblem 5：Measurement takes too long.\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003ePossible causes: Incorrect ending mode selected\u003c\/p\u003e\n\u003cp class=\"faq\"\u003e\u003cb\u003eProblem 6: Measurements are not repeatable.\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003ePossible causes: The samples are not homogeneous.\/ Drying time is too short.\/ The temp selected is too high and the sample has been oxidized.\/ The temperature sensor is contaminated or defective.\/ The sample is not completely dry.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch2 class=\"section-title3\"\u003eCE Certified Quality \u0026amp; Safety\u003c\/h2\u003e\n\u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/CE\/CE.jpg\"\u003e\n\u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/CE\/CE.jpg\"\u003e\n\u003ch2 class=\"section-title3\"\u003eAll Options\u003c\/h2\u003e\n\u003cdiv class=\"parameters-table-wrapper2\"\u003e\n\u003ctable class=\"parameters-table2\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/ussolid.com\/products\/moisture-analyzer-110g-x-5mg-0-1-readability-halogen-moisture-balance-by-u-s-solid-html\" target=\"_blank\"\u003e\u003cstrong\u003eUSS-HMA01\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/ussolid.com\/products\/moisture-analyzer-110g-x-1mg-0-01-readability-halogen-moisture-balance-by-u-s-solid-html\" target=\"_blank\"\u003e\u003cstrong\u003eUSS-HMA02\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/ussolid.com\/products\/moisture-analyzer-110g-x-1mg-0-01-readability-touch-screen-halogen-moisture-balance-by-u-s-solid-html\" target=\"_blank\"\u003e\u003cstrong\u003eUSS-HMA03\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/ussolid.com\/products\/moisture-analyzer-0-001-g-0-01-readability-moisture-balance-7-inch-touch-screen-html\" target=\"_blank\"\u003e\u003cstrong\u003eUSS-HMA11\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/ussolid.com\/products\/moisture-analyzer-0-001-g-0-01-readability-moisture-balance-7-inch-touch-screen-automatic-door-html\" target=\"_blank\"\u003e\u003cstrong\u003eUSS-HMA12\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/ussolid.com\/products\/moisture-analyzer-0-0001-g-0-001-readability-moisture-balance-7-inch-touch-screen-automatic-door-html\" target=\"_blank\"\u003e\u003cstrong\u003eUSS-HMA13\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/ussolid.com\/products\/moisture-analyzer-0-0001-g-0-001-readability-moisture-balance-7-inch-touch-screen-internal-calibration-and-automatic-door-html\" target=\"_blank\"\u003e\u003cstrong\u003eUSS-HMA14\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/ussolid.com\/products\/moisture-analyzer-0-01-g-0-1-readability-moisture-balance-5-inch-touch-screen-110-g-capacity-html\" target=\"_blank\"\u003e\u003cstrong\u003eUSS-HMA21\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/ussolid.com\/products\/moisture-analyzer-0-005-g-0-05-readability-moisture-balance-5-inch-touch-screen-110-g-capacity-html\" target=\"_blank\"\u003e\u003cstrong\u003eUSS-HMA22\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eUSS-HMA23\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003ePositioning\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eMainstream\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eHigh-end\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eEconomical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eWeight Readability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.005 g\u003c\/td\u003e\n\u003ctd\u003e0.001 g\u003c\/td\u003e\n\u003ctd\u003e0.001 g\u003c\/td\u003e\n\u003ctd\u003e0.001 g\u003c\/td\u003e\n\u003ctd\u003e0.001 g\u003c\/td\u003e\n\u003ctd\u003e0.0001 g\u003c\/td\u003e\n\u003ctd\u003e0.0001 g\u003c\/td\u003e\n\u003ctd\u003e0.01 g\u003c\/td\u003e\n\u003ctd\u003e0.005 g\u003c\/td\u003e\n\u003ctd\u003e0.001 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eMoisture Readability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 %\u003c\/td\u003e\n\u003ctd\u003e0.01 %\u003c\/td\u003e\n\u003ctd\u003e0.01 %\u003c\/td\u003e\n\u003ctd\u003e0.01 %\u003c\/td\u003e\n\u003ctd\u003e0.01 %\u003c\/td\u003e\n\u003ctd\u003e0.001 %\u003c\/td\u003e\n\u003ctd\u003e0.001 %\u003c\/td\u003e\n\u003ctd\u003e0.1 %\u003c\/td\u003e\n\u003ctd\u003e0.05 %\u003c\/td\u003e\n\u003ctd\u003e0.01 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eWeighing Sensor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eHigh-end strain gauge\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eHigh-end strain gauge\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eElectromagnetic force\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eStrain gauge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eControl Panel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePush Button\u003c\/td\u003e\n\u003ctd\u003ePush Button\u003c\/td\u003e\n\u003ctd\u003e5\" Touch Screen\u003c\/td\u003e\n\u003ctd\u003e7\" Touch Screen\u003c\/td\u003e\n\u003ctd\u003e7\" Touch Screen\u003c\/td\u003e\n\u003ctd\u003e7\" Touch Screen\u003c\/td\u003e\n\u003ctd\u003e7\" Touch Screen\u003c\/td\u003e\n\u003ctd\u003e5\" Touch Screen\u003c\/td\u003e\n\u003ctd\u003e5\" Touch Screen\u003c\/td\u003e\n\u003ctd\u003e5\" Touch Screen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eCalibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eAuto\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eHeater Cover\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eAuto\u003c\/td\u003e\n\u003ctd\u003eAuto\u003c\/td\u003e\n\u003ctd\u003eAuto\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eData Storage Group\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003e200\u003c\/td\u003e\n\u003ctd\u003e200\u003c\/td\u003e\n\u003ctd\u003e200\u003c\/td\u003e\n\u003ctd\u003e200\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e40℃ - 199℃\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e40 ℃ - 200℃\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e40 ℃ - 160℃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eDrying mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eStandard, Fast, Soft\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eStandard, Fast, Soft, Step\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eStandard, Fast, Soft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eEnding mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"10\"\u003eAuto, Timing, Manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003ePan size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eΦ90 mm\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eΦ100 mm\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eΦ100 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"10\"\u003eRS-232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/body\u003e","brand":"U.S. Solid","offers":[{"title":"Default Title","offer_id":46324259225855,"sku":"JFHMA00023","price":597.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/1_dac2f917-1ce3-491f-b644-8c139eae81f4.png?v=1752564423"},{"product_id":"moisture-analyzer-0-01-g-0-1-readability-moisture-balance-5-inch-touch-screen-110-g-capacity-html","title":"Moisture Analyzer - 0.01 g, 0.1% Readability Moisture Balance, 5-inch Touch Screen, 110 g Capacity","description":"\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e \u003cmeta content=\"width=device-width, initial-scale=1.0\" name=\"viewport\"\u003e\u003c\/p\u003e\n\u003cstyle\u003e\n        \n        .desktop-img {\n            display: block;\n        }\n        .mobile-img {\n            display: none;\n        } \n\n        \n        .section-title {\n            font-size: 22px;\n            line-height: 22px;\n            font-weight: bold;\n            margin: 15px 0 5px; \n            font-family: Arial;\n        }\n        \n        .section-title2 {\n            font-size: 22px;\n            line-height: 22px;\n            font-weight: bold;\n            margin: 15px 0 3px; \n            font-family: Arial;\n        }\n        \n        .section-title3 {\n            font-size: 22px;\n            line-height: 22px;\n            font-weight: bold;\n            margin: 15px 0 10px; \n            font-family: Arial;\n        }\n\n        \n        .section-description {\n            font-size: 16px;\n            line-height: 26px;\n            margin-top: 0px;\n            margin-bottom: 5px; \n            font-family: Arial;\n        }\n        \n        .faq {\n            font-size: 16px; \n            margin: 0; \n            line-height: 26px; \n            background-color: #f2f2f2; \n            padding: 5px;\n        }\n        \n        .section-description2 {\n            font-size: 16px;\n            line-height: 26px;\n            margin: 0px; \n            font-family: Arial;\n        }\n        \n.parameters-table-wrapper {\n    overflow-x: auto; \n    -webkit-overflow-scrolling: touch; \n    margin-top: 0px;\n}\n\n\n.parameters-table {\n    width: 100%;\n    min-width: 1000px; \n    border-collapse: collapse;\n    margin-top: 0px;\n}\n\n.parameters-table th, .parameters-table td {\n    border-top: 1.2px solid #a6a6a6;  \n    border-bottom: 1.2px solid #a6a6a6;  \n    border-left: none;  \n    border-right: none;  \n    padding: 5px 2px;\n    text-align: left;\n    font-size: 16px;\n    line-height: 16px;\n}\n\n.parameters-table th {\n    background-color: #f2f2f2;\n    color: #2c2c2c;\n    font-weight: bold;\n}\n\n\n.parameters-table .bg-gray {\n    background-color: #f2f2f2;  \n}\n\n\n.options-table-wrapper {\n    overflow-x: auto; \n    -webkit-overflow-scrolling: touch; \n    margin-top: 0px;\n}\n\n.options-table {\n    width: 100%;\n    min-width: 1000px; \n    border-collapse: collapse;\n    margin-top: 0px;\n    box-shadow: 0 6px 25px rgba(0, 0, 0, 0.1); \n}\n\n.options-table th, .options-table td {\n    border: 2px solid #000;  \n    padding: 5px 2px;  \n    text-align: center;\n    font-size: 16px;\n    line-height: 16px;\n}\n\n.options-table th {\n    background-color: #f2f2f2;\n    color: #2c2c2c;\n    font-weight: bold;\n}\n\n\n.parameters-table2 {\n    width: 100%;\n    min-width: 1000px; \n    border-collapse: collapse;\n    margin-top: 0px;\n}\n\n.parameters-table2 th, .parameters-table2 td {\n    border-top: 1.2px solid #a6a6a6;  \n    border-bottom: 1.2px solid #a6a6a6;  \n    border-left: none;  \n    border-right: none;  \n    padding: 5px 2px;\n    text-align: center;\n    font-size: 16px;\n    line-height: 16px;\n}\n\n.parameters-table2 th {\n    background-color: #f2f2f2;\n    color: #2c2c2c;\n    font-weight: bold;\n}\n\n\n.parameters-table2 .bg-gray {\n    background-color: #f2f2f2;  \n}\n\n\n.options-table-wrapper2 {\n    overflow-x: auto; \n    -webkit-overflow-scrolling: touch; \n    margin-top: 0px;\n}\n\n\n@media (max-width: 768px) {\n    .parameters-table th, .parameters-table td {\n        font-size: 14px; \n        padding: 8px 4px; \n    }\n\n    \n    .options-table th, .options-table td {\n        font-size: 14px; \n        padding: 8px 4px;\n    }\n\n    .parameters-table-wrapper {\n        overflow-x: auto;\n    }\n    .parameters-table2 th, .parameters-table2 td {\n        font-size: 14px; \n        padding: 8px 4px; \n    }\n    .parameters-table-wrapper2 {\n        overflow-x: auto;\n    }\n    .desktop-img {\n                display: none; \n            }\n            .mobile-img {\n                display: block; \n            }\n    \n}\n\n@media (max-width: 480px) {\n    .parameters-table th, .parameters-table td {\n        font-size: 12px; \n        padding: 6px 3px; \n    }\n\n    \n    .options-table th, .options-table td {\n        font-size: 12px; \n    }\n\n    .parameters-table-wrapper {\n        overflow-x: auto;\n    }\n    .parameters-table2 th, .parameters-table2 td {\n        font-size: 12px; \n        padding: 6px 3px; \n    }\n    .parameters-table-wrapper2 {\n        overflow-x: auto;\n    }\n    .desktop-img {\n                display: none; \n            }\n            .mobile-img {\n                display: block; \n            }\n    \n}\n    \u003c\/style\u003e\n\u003cp\u003e\u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHMA\/jfhma21-background.png\"\u003e \u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHMA\/USS-HMA21.png\"\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003ch2 class=\"section-title\"\u003eIntroduction\u003c\/h2\u003e\n\u003cp class=\"section-description\"\u003eThe U.S. Solid USS-HMA21 Moisture Analyzer provides a high level of operating convenience and response sensitivity to facilitate determination of the moisture content of your samples.\u003cbr\u003eIt comes with smart functionalities that allows you to preset and store measuring methods, so you can access the options with ease. The device is equipped with a 250W halogen lamp and a strain gauge weighing sensor. As an economical model, it effectively meets basic usage needs. USS-HMA21 moisture balance incorporates a 5-inch LCD color touch-panel that displays with higher accuracy and clarity any test result than general panel. Compact, practical, and easy to use, this moisture balance is a better choice for every lab.\u003cbr\u003eMoisture analyzers work according to the thermogravimetric principle. Moisture is determined by the direct weight lost by the sample due to heating from an intense halogen light.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch2 class=\"section-title2\"\u003eApplications\u003c\/h2\u003e\n\u003cp\u003e\u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHMA\/jfhma01-3%281%29.jpg\"\u003e \u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHMA\/jfhma-background.jpg\"\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003ch2 class=\"section-title\"\u003eFeatures\u003c\/h2\u003e\n\u003cul class=\"section-description2\"\u003e\n\u003cli\u003eReadability: 0.01g\u003c\/li\u003e\n\u003cli\u003eMoisture readability: 0.1%\u003c\/li\u003e\n\u003cli\u003eManual calibration\u003c\/li\u003e\n\u003cli\u003eWeighing sensor: Strain gauge\u003c\/li\u003e\n\u003cli\u003e5-inch LCD color touch-panel: Displays real-time testing curve\u003c\/li\u003e\n\u003cli\u003eEfficient preheat function: The moisture balance is equipped with an advanced preheat function that significantly expedites the heating process.\u003c\/li\u003e\n\u003cli\u003e3 drying modes (standard\/fast\/soft)\u003c\/li\u003e\n\u003cli\u003e3 ending modes (automatic\/manual\/timing)\u003c\/li\u003e\n\u003cli\u003e20 groups of methods can be preset and stored\u003c\/li\u003e\n\u003cli\u003e3 kinds of result display (moisture percentage\/dry weight\/dry-weight percentage)\u003c\/li\u003e\n\u003cli\u003e20 sample pans included\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch2 class=\"section-title\"\u003eMore Details\u003c\/h2\u003e\n\u003cp\u003e\u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHMA\/jfhma21.jpg\"\u003e \u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHMA\/jfhma21-22-23-p-2.png\"\u003e\u003c\/p\u003e\n\u003ch2 class=\"section-title\"\u003eUser Manual\u003c\/h2\u003e\n\u003cp class=\"section-description\"\u003eFor detailed information on calibration, installation, setup, and usage, please refer to the \u003ca href=\"https:\/\/file.ussolid.com\/content\/JFHMA\/Instruction%20Manual%20-%20USS-HMA2X%20Moisture%20Analyzer.pdf\" target=\"_blank\"\u003euser manual\u003c\/a\u003e and watch the \u003ca href=\"https:\/\/www.youtube.com\/watch?v=hKKFibpT3kg\" target=\"_blank\"\u003etutorial video\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch2 class=\"section-title3\"\u003eTechnical Data\u003c\/h2\u003e\n\u003cdiv class=\"parameters-table-wrapper\"\u003e\n\u003ctable class=\"parameters-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSS-HMA21\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eCalibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eCapacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110 g\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eDisplays of results\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e[%m]\/ [%]\/ [g]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eWeight Readability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01 g\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eCalibration Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eMoisture Readability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1%\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eStabilization Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 3s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eHeating Element\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250W Halogen Lamp\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003ePan size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/ussolid.com\/products\/50-pack-aluminum-sample-pan-100-mm-for-u-s-solid-moisture-analyzers?_pos=1\u0026amp;_sid=4dab01060\u0026amp;_ss=r\" target=\"_blank\"\u003eΦ100mm\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eOperating temperature range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e104℉-320℉ (40℃-160℃)\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRS-232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eAmbient temperature range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e41℉-95℉ (5℃-35℃)\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eHeater Cover\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eTime setting range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 - 99 min\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003ePower\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110V 60Hz AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eDrying mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard\/ Fast\/ Soft\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eProduct dimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.5*13.6*6.7 inches(190*345*170 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eEnding mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAuto\/ Timing\/ Manual\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6.57 lbs (2.98 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ch2 class=\"section-title\"\u003eTroubleshooting\u003c\/h2\u003e\n\u003cp class=\"faq\"\u003e\u003cb\u003eProblem 1: Display remains off after switching on.\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003ePossible causes: Power cord is not connected\/ Power line fuse blown\/ Power supply interrupted\/ Instrument faulty\u003c\/p\u003e\n\u003cp class=\"faq\"\u003e\u003cb\u003eProblem 2: Display does not change when loading samples.\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003ePossible causes: The sample pan\/pan holder is not installed correctly.\u003c\/p\u003e\n\u003cp class=\"faq\"\u003e\u003cb\u003eProblem 3: Weight display is constantly changing or unstable.\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003ePossible causes: The sample pan is in contact with the draft shield or heating chamber\/ Air movement\/ Test bench vibration\/ Electromagnetic field interference\u003c\/p\u003e\n\u003cp class=\"faq\"\u003e\u003cb\u003eProblem 4: Drying does not start.\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003ePossible causes: Heating chamber open\/ Power cord is not connected\/ Power line fuse blown\u003c\/p\u003e\n\u003cp class=\"faq\"\u003e\u003cb\u003eProblem 5：Measurement takes too long.\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003ePossible causes: Incorrect ending mode selected\u003c\/p\u003e\n\u003cp class=\"faq\"\u003e\u003cb\u003eProblem 6: Measurements are not repeatable.\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003ePossible causes: The samples are not homogeneous.\/ Drying time is too short.\/ The temp selected is too high and the sample has been oxidized.\/ The temperature sensor is contaminated or defective.\/ The sample is not completely dry.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch2 class=\"section-title3\"\u003eCE Certified Quality \u0026amp; Safety\u003c\/h2\u003e\n\u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/CE\/CE.jpg\"\u003e\n\u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/CE\/CE.jpg\"\u003e\n\u003ch2 class=\"section-title3\"\u003eAll Options\u003c\/h2\u003e\n\u003cdiv class=\"parameters-table-wrapper2\"\u003e\n\u003ctable class=\"parameters-table2\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/ussolid.com\/products\/moisture-analyzer-110g-x-5mg-0-1-readability-halogen-moisture-balance-by-u-s-solid-html\" target=\"_blank\"\u003e\u003cstrong\u003eUSS-HMA01\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/ussolid.com\/products\/moisture-analyzer-110g-x-1mg-0-01-readability-halogen-moisture-balance-by-u-s-solid-html\" target=\"_blank\"\u003e\u003cstrong\u003eUSS-HMA02\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/ussolid.com\/products\/moisture-analyzer-110g-x-1mg-0-01-readability-touch-screen-halogen-moisture-balance-by-u-s-solid-html\" target=\"_blank\"\u003e\u003cstrong\u003eUSS-HMA03\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/ussolid.com\/products\/moisture-analyzer-0-001-g-0-01-readability-moisture-balance-7-inch-touch-screen-html\" target=\"_blank\"\u003e\u003cstrong\u003eUSS-HMA11\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/ussolid.com\/products\/moisture-analyzer-0-001-g-0-01-readability-moisture-balance-7-inch-touch-screen-automatic-door-html\" target=\"_blank\"\u003e\u003cstrong\u003eUSS-HMA12\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/ussolid.com\/products\/moisture-analyzer-0-0001-g-0-001-readability-moisture-balance-7-inch-touch-screen-automatic-door-html\" target=\"_blank\"\u003e\u003cstrong\u003eUSS-HMA13\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/ussolid.com\/products\/moisture-analyzer-0-0001-g-0-001-readability-moisture-balance-7-inch-touch-screen-internal-calibration-and-automatic-door-html\" target=\"_blank\"\u003e\u003cstrong\u003eUSS-HMA14\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eUSS-HMA21\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/ussolid.com\/products\/moisture-analyzer-0-005-g-0-05-readability-moisture-balance-5-inch-touch-screen-110-g-capacity-html\" target=\"_blank\"\u003e\u003cstrong\u003eUSS-HMA22\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/ussolid.com\/products\/moisture-analyzer-0-001-g-0-01-readability-moisture-balance-5-inch-touch-screen-110-g-capacity-html\" target=\"_blank\"\u003e\u003cstrong\u003eUSS-HMA23\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003ePositioning\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eMainstream\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eHigh-end\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eEconomical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eWeight Readability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.005 g\u003c\/td\u003e\n\u003ctd\u003e0.001 g\u003c\/td\u003e\n\u003ctd\u003e0.001 g\u003c\/td\u003e\n\u003ctd\u003e0.001 g\u003c\/td\u003e\n\u003ctd\u003e0.001 g\u003c\/td\u003e\n\u003ctd\u003e0.0001 g\u003c\/td\u003e\n\u003ctd\u003e0.0001 g\u003c\/td\u003e\n\u003ctd\u003e0.01 g\u003c\/td\u003e\n\u003ctd\u003e0.005 g\u003c\/td\u003e\n\u003ctd\u003e0.001 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eMoisture Readability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 %\u003c\/td\u003e\n\u003ctd\u003e0.01 %\u003c\/td\u003e\n\u003ctd\u003e0.01 %\u003c\/td\u003e\n\u003ctd\u003e0.01 %\u003c\/td\u003e\n\u003ctd\u003e0.01 %\u003c\/td\u003e\n\u003ctd\u003e0.001 %\u003c\/td\u003e\n\u003ctd\u003e0.001 %\u003c\/td\u003e\n\u003ctd\u003e0.1 %\u003c\/td\u003e\n\u003ctd\u003e0.05 %\u003c\/td\u003e\n\u003ctd\u003e0.01 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eWeighing Sensor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eHigh-end strain gauge\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eHigh-end strain gauge\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eElectromagnetic force\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eStrain gauge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eControl Panel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePush Button\u003c\/td\u003e\n\u003ctd\u003ePush Button\u003c\/td\u003e\n\u003ctd\u003e5\" Touch Screen\u003c\/td\u003e\n\u003ctd\u003e7\" Touch Screen\u003c\/td\u003e\n\u003ctd\u003e7\" Touch Screen\u003c\/td\u003e\n\u003ctd\u003e7\" Touch Screen\u003c\/td\u003e\n\u003ctd\u003e7\" Touch Screen\u003c\/td\u003e\n\u003ctd\u003e5\" Touch Screen\u003c\/td\u003e\n\u003ctd\u003e5\" Touch Screen\u003c\/td\u003e\n\u003ctd\u003e5\" Touch Screen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eCalibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eAuto\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eHeater Cover\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eAuto\u003c\/td\u003e\n\u003ctd\u003eAuto\u003c\/td\u003e\n\u003ctd\u003eAuto\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eData Storage Group\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003e200\u003c\/td\u003e\n\u003ctd\u003e200\u003c\/td\u003e\n\u003ctd\u003e200\u003c\/td\u003e\n\u003ctd\u003e200\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e40℃ - 199℃\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e40 ℃ - 200℃\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e40 ℃ - 160℃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eDrying mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eStandard, Fast, Soft\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eStandard, Fast, Soft, Step\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eStandard, Fast, Soft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eEnding mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"10\"\u003eAuto, Timing, Manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003ePan size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eΦ90 mm\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eΦ100 mm\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eΦ100 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"10\"\u003eRS-232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"U.S. Solid","offers":[{"title":"Default Title","offer_id":46324259356927,"sku":"JFHMA00021","price":427.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/1_406a7c4e-dc6d-4728-9b75-0f65c93477d8.png?v=1752564251"},{"product_id":"moisture-analyzer-0-005-g-0-05-readability-moisture-balance-5-inch-touch-screen-110-g-capacity-html","title":"Moisture Analyzer - 0.005 g, 0.05% Readability Moisture Balance, 5-inch Touch Screen, 110 g Capacity","description":"\u003cbody\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003cmeta content=\"width=device-width, initial-scale=1.0\" name=\"viewport\"\u003e\n\u003ctitle\u003eResponsive Page with Multiple Modules\u003c\/title\u003e\n\u003cstyle\u003e\n        \n        .desktop-img {\n            display: block;\n        }\n        .mobile-img {\n            display: none;\n        } \n\n        \n        .section-title {\n            font-size: 22px;\n            line-height: 22px;\n            font-weight: bold;\n            margin: 15px 0 5px; \n            font-family: Arial;\n        }\n        \n        .section-title2 {\n            font-size: 22px;\n            line-height: 22px;\n            font-weight: bold;\n            margin: 15px 0 3px; \n            font-family: Arial;\n        }\n        \n        .section-title3 {\n            font-size: 22px;\n            line-height: 22px;\n            font-weight: bold;\n            margin: 15px 0 10px; \n            font-family: Arial;\n        }\n\n        \n        .section-description {\n            font-size: 16px;\n            line-height: 26px;\n            margin-top: 0px;\n            margin-bottom: 5px; \n            font-family: Arial;\n        }\n        \n        .faq {\n            font-size: 16px; \n            margin: 0; \n            line-height: 26px; \n            background-color: #f2f2f2; \n            padding: 5px;\n        }\n        \n        .section-description2 {\n            font-size: 16px;\n            line-height: 26px;\n            margin: 0px; \n            font-family: Arial;\n        }\n        \n.parameters-table-wrapper {\n    overflow-x: auto; \n    -webkit-overflow-scrolling: touch; \n    margin-top: 0px;\n}\n\n\n.parameters-table {\n    width: 100%;\n    min-width: 1000px; \n    border-collapse: collapse;\n    margin-top: 0px;\n}\n\n.parameters-table th, .parameters-table td {\n    border-top: 1.2px solid #a6a6a6;  \n    border-bottom: 1.2px solid #a6a6a6;  \n    border-left: none;  \n    border-right: none;  \n    padding: 5px 2px;\n    text-align: left;\n    font-size: 16px;\n    line-height: 16px;\n}\n\n.parameters-table th {\n    background-color: #f2f2f2;\n    color: #2c2c2c;\n    font-weight: bold;\n}\n\n\n.parameters-table .bg-gray {\n    background-color: #f2f2f2;  \n}\n\n\n.options-table-wrapper {\n    overflow-x: auto; \n    -webkit-overflow-scrolling: touch; \n    margin-top: 0px;\n}\n\n.options-table {\n    width: 100%;\n    min-width: 1000px; \n    border-collapse: collapse;\n    margin-top: 0px;\n    box-shadow: 0 6px 25px rgba(0, 0, 0, 0.1); \n}\n\n.options-table th, .options-table td {\n    border: 2px solid #000;  \n    padding: 5px 2px;  \n    text-align: center;\n    font-size: 16px;\n    line-height: 16px;\n}\n\n.options-table th {\n    background-color: #f2f2f2;\n    color: #2c2c2c;\n    font-weight: bold;\n}\n\n\n.parameters-table2 {\n    width: 100%;\n    min-width: 1000px; \n    border-collapse: collapse;\n    margin-top: 0px;\n}\n\n.parameters-table2 th, .parameters-table2 td {\n    border-top: 1.2px solid #a6a6a6;  \n    border-bottom: 1.2px solid #a6a6a6;  \n    border-left: none;  \n    border-right: none;  \n    padding: 5px 2px;\n    text-align: center;\n    font-size: 16px;\n    line-height: 16px;\n}\n\n.parameters-table2 th {\n    background-color: #f2f2f2;\n    color: #2c2c2c;\n    font-weight: bold;\n}\n\n\n.parameters-table2 .bg-gray {\n    background-color: #f2f2f2;  \n}\n\n\n.options-table-wrapper2 {\n    overflow-x: auto; \n    -webkit-overflow-scrolling: touch; \n    margin-top: 0px;\n}\n\n\n@media (max-width: 768px) {\n    .parameters-table th, .parameters-table td {\n        font-size: 14px; \n        padding: 8px 4px; \n    }\n\n    \n    .options-table th, .options-table td {\n        font-size: 14px; \n        padding: 8px 4px;\n    }\n\n    .parameters-table-wrapper {\n        overflow-x: auto;\n    }\n    .parameters-table2 th, .parameters-table2 td {\n        font-size: 14px; \n        padding: 8px 4px; \n    }\n    .parameters-table-wrapper2 {\n        overflow-x: auto;\n    }\n    .desktop-img {\n                display: none; \n            }\n            .mobile-img {\n                display: block; \n            }\n    \n}\n\n@media (max-width: 480px) {\n    .parameters-table th, .parameters-table td {\n        font-size: 12px; \n        padding: 6px 3px; \n    }\n\n    \n    .options-table th, .options-table td {\n        font-size: 12px; \n    }\n\n    .parameters-table-wrapper {\n        overflow-x: auto;\n    }\n    .parameters-table2 th, .parameters-table2 td {\n        font-size: 12px; \n        padding: 6px 3px; \n    }\n    .parameters-table-wrapper2 {\n        overflow-x: auto;\n    }\n    .desktop-img {\n                display: none; \n            }\n            .mobile-img {\n                display: block; \n            }\n    \n}\n    \u003c\/style\u003e\n\u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHMA\/jfhma22-background.png\"\u003e\n\u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHMA\/USS-HMA22.png\"\u003e\n\u003cdiv\u003e\n\u003ch2 class=\"section-title\"\u003eIntroduction\u003c\/h2\u003e\n\u003cp class=\"section-description\"\u003e\n            The U.S. Solid USS-HMA22 Moisture Analyzer provides a high level of operating convenience and response sensitivity to facilitate determination of the moisture content of your samples.\u003cbr\u003e\n            It comes with smart functionalities that allows you to preset and store measuring methods, so you can access the options with ease. The device is equipped with a 250W halogen lamp and a strain gauge weighing sensor. As an economical model, it effectively meets basic usage needs. USS-HMA22 moisture balance incorporates a 5-inch LCD color touch-panel that displays with higher accuracy and clarity any test result than general panel. Compact, practical, and easy to use, this moisture balance is a better choice for every lab.\u003cbr\u003eMoisture analyzers work according to the thermogravimetric principle. Moisture is determined by the direct weight lost by the sample due to heating from an intense halogen light.\n        \u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch2 class=\"section-title2\"\u003eApplications\u003c\/h2\u003e\n\u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHMA\/jfhma01-3%281%29.jpg\"\u003e\n\u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHMA\/jfhma-background.jpg\"\u003e\n\u003cdiv\u003e\n\u003ch2 class=\"section-title\"\u003eFeatures\u003c\/h2\u003e\n\u003cul class=\"section-description2\"\u003e\n\u003cli\u003eReadability: 0.005g\u003c\/li\u003e\n\u003cli\u003eMoisture readability: 0.05%\u003c\/li\u003e\n\u003cli\u003eManual calibration\u003c\/li\u003e\n\u003cli\u003eWeighing sensor: Strain gauge\u003c\/li\u003e\n\u003cli\u003e5-inch LCD color touch-panel: Displays real-time testing curve\u003c\/li\u003e\n\u003cli\u003eEfficient preheat function: The moisture balance is equipped with an advanced preheat function that significantly expedites the heating process.\u003c\/li\u003e\n\u003cli\u003e3 drying modes (standard\/fast\/soft)\u003c\/li\u003e\n\u003cli\u003e3 ending modes (automatic\/manual\/timing)\u003c\/li\u003e\n\u003cli\u003e20 groups of methods can be preset and stored\u003c\/li\u003e\n\u003cli\u003e3 kinds of result display (moisture percentage\/dry weight\/dry-weight percentage)\u003c\/li\u003e\n\u003cli\u003e20 sample pans included\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch2 class=\"section-title\"\u003eMore Details\u003c\/h2\u003e\n\u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHMA\/jfhma21.jpg\"\u003e\n\u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHMA\/jfhma21-22-23-p-2.png\"\u003e\n\u003ch2 class=\"section-title\"\u003eUser Manual\u003c\/h2\u003e\n\u003cp class=\"section-description\"\u003e\n            For detailed information on calibration, installation, setup, and usage, please refer to the \u003ca href=\"https:\/\/file.ussolid.com\/content\/JFHMA\/Instruction%20Manual%20-%20USS-HMA2X%20Moisture%20Analyzer.pdf\" target=\"_blank\"\u003euser manual\u003c\/a\u003e and watch the \u003ca href=\"https:\/\/www.youtube.com\/watch?v=hKKFibpT3kg\" target=\"_blank\"\u003etutorial video\u003c\/a\u003e.\n    \u003c\/p\u003e\n\u003ch2 class=\"section-title3\"\u003eTechnical Data\u003c\/h2\u003e\n\u003cdiv class=\"parameters-table-wrapper\"\u003e\n\u003ctable class=\"parameters-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSS-HMA22\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eCalibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eCapacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110 g\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eDisplays of results\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e[%m]\/ [%]\/ [g]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eWeight Readability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.005 g\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eCalibration Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eMoisture Readability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.05%\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eStabilization Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 3s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eHeating Element\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250W Halogen Lamp\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003ePan size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/ussolid.com\/products\/50-pack-aluminum-sample-pan-100-mm-for-u-s-solid-moisture-analyzers?_pos=1\u0026amp;_sid=4dab01060\u0026amp;_ss=r\" target=\"_blank\"\u003eΦ100mm\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eOperating temperature range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e104℉-320℉ (40℃-160℃)\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRS-232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eAmbient temperature range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e41℉-95℉ (5℃-35℃)\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eHeater Cover\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eTime setting range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 - 99 min\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003ePower\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110V 60Hz AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eDrying mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard\/ Fast\/ Soft\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eProduct dimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.5*13.6*6.7 inches(190*345*170 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eEnding mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAuto\/ Timing\/ Manual\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6.57 lbs (2.98 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ch2 class=\"section-title\"\u003eTroubleshooting\u003c\/h2\u003e\n\u003cp class=\"faq\"\u003e\u003cb\u003eProblem 1: Display remains off after switching on.\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003ePossible causes: Power cord is not connected\/ Power line fuse blown\/ Power supply interrupted\/ Instrument faulty\u003c\/p\u003e\n\u003cp class=\"faq\"\u003e\u003cb\u003eProblem 2: Display does not change when loading samples.\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003ePossible causes: The sample pan\/pan holder is not installed correctly.\u003c\/p\u003e\n\u003cp class=\"faq\"\u003e\u003cb\u003eProblem 3: Weight display is constantly changing or unstable.\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003ePossible causes: The sample pan is in contact with the draft shield or heating chamber\/ Air movement\/ Test bench vibration\/ Electromagnetic field interference\u003c\/p\u003e\n\u003cp class=\"faq\"\u003e\u003cb\u003eProblem 4: Drying does not start.\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003ePossible causes: Heating chamber open\/ Power cord is not connected\/ Power line fuse blown\u003c\/p\u003e\n\u003cp class=\"faq\"\u003e\u003cb\u003eProblem 5：Measurement takes too long.\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003ePossible causes: Incorrect ending mode selected\u003c\/p\u003e\n\u003cp class=\"faq\"\u003e\u003cb\u003eProblem 6: Measurements are not repeatable.\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003ePossible causes: The samples are not homogeneous.\/ Drying time is too short.\/ The temp selected is too high and the sample has been oxidized.\/ The temperature sensor is contaminated or defective.\/ The sample is not completely dry.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch2 class=\"section-title3\"\u003eCE Certified Quality \u0026amp; Safety\u003c\/h2\u003e\n\u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/CE\/CE.jpg\"\u003e\n\u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/CE\/CE.jpg\"\u003e\n\u003ch2 class=\"section-title3\"\u003eAll Options\u003c\/h2\u003e\n\u003cdiv class=\"parameters-table-wrapper2\"\u003e\n\u003ctable class=\"parameters-table2\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/ussolid.com\/products\/moisture-analyzer-110g-x-5mg-0-1-readability-halogen-moisture-balance-by-u-s-solid-html\" target=\"_blank\"\u003e\u003cstrong\u003eUSS-HMA01\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/ussolid.com\/products\/moisture-analyzer-110g-x-1mg-0-01-readability-halogen-moisture-balance-by-u-s-solid-html\" target=\"_blank\"\u003e\u003cstrong\u003eUSS-HMA02\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/ussolid.com\/products\/moisture-analyzer-110g-x-1mg-0-01-readability-touch-screen-halogen-moisture-balance-by-u-s-solid-html\" target=\"_blank\"\u003e\u003cstrong\u003eUSS-HMA03\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/ussolid.com\/products\/moisture-analyzer-0-001-g-0-01-readability-moisture-balance-7-inch-touch-screen-html\" target=\"_blank\"\u003e\u003cstrong\u003eUSS-HMA11\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/ussolid.com\/products\/moisture-analyzer-0-001-g-0-01-readability-moisture-balance-7-inch-touch-screen-automatic-door-html\" target=\"_blank\"\u003e\u003cstrong\u003eUSS-HMA12\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/ussolid.com\/products\/moisture-analyzer-0-0001-g-0-001-readability-moisture-balance-7-inch-touch-screen-automatic-door-html\" target=\"_blank\"\u003e\u003cstrong\u003eUSS-HMA13\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/ussolid.com\/products\/moisture-analyzer-0-0001-g-0-001-readability-moisture-balance-7-inch-touch-screen-internal-calibration-and-automatic-door-html\" target=\"_blank\"\u003e\u003cstrong\u003eUSS-HMA14\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/ussolid.com\/products\/moisture-analyzer-0-01-g-0-1-readability-moisture-balance-5-inch-touch-screen-110-g-capacity-html\" target=\"_blank\"\u003e\u003cstrong\u003eUSS-HMA21\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eUSS-HMA22\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/ussolid.com\/products\/moisture-analyzer-0-001-g-0-01-readability-moisture-balance-5-inch-touch-screen-110-g-capacity-html\" target=\"_blank\"\u003e\u003cstrong\u003eUSS-HMA23\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003ePositioning\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eMainstream\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eHigh-end\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eEconomical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eWeight Readability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.005 g\u003c\/td\u003e\n\u003ctd\u003e0.001 g\u003c\/td\u003e\n\u003ctd\u003e0.001 g\u003c\/td\u003e\n\u003ctd\u003e0.001 g\u003c\/td\u003e\n\u003ctd\u003e0.001 g\u003c\/td\u003e\n\u003ctd\u003e0.0001 g\u003c\/td\u003e\n\u003ctd\u003e0.0001 g\u003c\/td\u003e\n\u003ctd\u003e0.01 g\u003c\/td\u003e\n\u003ctd\u003e0.005 g\u003c\/td\u003e\n\u003ctd\u003e0.001 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eMoisture Readability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 %\u003c\/td\u003e\n\u003ctd\u003e0.01 %\u003c\/td\u003e\n\u003ctd\u003e0.01 %\u003c\/td\u003e\n\u003ctd\u003e0.01 %\u003c\/td\u003e\n\u003ctd\u003e0.01 %\u003c\/td\u003e\n\u003ctd\u003e0.001 %\u003c\/td\u003e\n\u003ctd\u003e0.001 %\u003c\/td\u003e\n\u003ctd\u003e0.1 %\u003c\/td\u003e\n\u003ctd\u003e0.05 %\u003c\/td\u003e\n\u003ctd\u003e0.01 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eWeighing Sensor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eHigh-end strain gauge\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eHigh-end strain gauge\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eElectromagnetic force\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eStrain gauge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eControl Panel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePush Button\u003c\/td\u003e\n\u003ctd\u003ePush Button\u003c\/td\u003e\n\u003ctd\u003e5\" Touch Screen\u003c\/td\u003e\n\u003ctd\u003e7\" Touch Screen\u003c\/td\u003e\n\u003ctd\u003e7\" Touch Screen\u003c\/td\u003e\n\u003ctd\u003e7\" Touch Screen\u003c\/td\u003e\n\u003ctd\u003e7\" Touch Screen\u003c\/td\u003e\n\u003ctd\u003e5\" Touch Screen\u003c\/td\u003e\n\u003ctd\u003e5\" Touch Screen\u003c\/td\u003e\n\u003ctd\u003e5\" Touch Screen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eCalibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eAuto\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eHeater Cover\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eAuto\u003c\/td\u003e\n\u003ctd\u003eAuto\u003c\/td\u003e\n\u003ctd\u003eAuto\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eData Storage Group\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003e200\u003c\/td\u003e\n\u003ctd\u003e200\u003c\/td\u003e\n\u003ctd\u003e200\u003c\/td\u003e\n\u003ctd\u003e200\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e40℃ - 199℃\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e40 ℃ - 200℃\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e40 ℃ - 160℃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eDrying mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eStandard, Fast, Soft\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eStandard, Fast, Soft, Step\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eStandard, Fast, Soft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eEnding mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"10\"\u003eAuto, Timing, Manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003ePan size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eΦ90 mm\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eΦ100 mm\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eΦ100 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"10\"\u003eRS-232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/body\u003e","brand":"U.S. Solid","offers":[{"title":"Default Title","offer_id":46324259586303,"sku":"JFHMA00022","price":501.38,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/1_dac2f917-1ce3-491f-b644-8c139eae81f4.png?v=1752564423"},{"product_id":"thermal-printer-for-u-s-solid-moisture-analyzers-2-inches-s-speed-2-1-4-width-paper-rs232-html","title":"Thermal Printer for U.S. Solid Moisture Analyzers - 2 inches\/s Speed, 2-1\/4\" width Paper, RS232","description":"\u003cp\u003e\u003cspan style=\"font-size: medium;\"\u003eOur cutting-edge thermal printer is optimized for quick, sharp, and energy-saving printing. It operates at a high printing speed of 50 mm\/s and is suitable for use with all U.S. Solid moisture analyzers. With an RS-232 port for effortless data transfer, it uses standard 2-1\/4 inch (57 mm) width paper. The printer produces detailed printouts that include moisture content, weight, testing mode, temperature, and duration information. This thermal printer is an excellent solution for efficient, flexible, and comprehensive printing tasks.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"font-size: medium;\"\u003eSpecifications:\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan style=\"font-size: medium;\"\u003eModel: USS-HMA04\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-size: medium;\"\u003ePrint Speed: 2 inches\/s (50 mm\/s)\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-size: medium;\"\u003ePrinting Type: Thermal printing\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-size: medium;\"\u003eInterface: RS-232\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-size: medium;\"\u003ePrint Resolution: High definition\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-size: medium;\"\u003ePaper Width: 2.25 inches\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-size: medium;\"\u003eDimensions: 5.9*4.8*3.7 inches\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-size: medium;\"\u003eColor: Black\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-size: medium;\"\u003eAdaptability: All U.S. Solid moisture analyzers\u003c\/span\u003e\u003c\/p\u003e","brand":"U.S. Solid","offers":[{"title":"Default Title","offer_id":46324260733183,"sku":"JFHMA00004","price":99.7,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/1_cf50e889-f6be-4a6c-874e-0f42673e0911.jpg?v=1733399296"},{"product_id":"50-pack-aluminum-sample-pan-100-mm-for-u-s-solid-moisture-analyzers","title":"50-Pack Aluminum Sample Pan 100 mm for U.S. Solid Moisture Analyzers","description":"\u003cdiv class=\"powr-popup\"\u003e\n\u003cp\u003e\u003cspan style=\"font-size: medium;\"\u003eThe Aluminum Sample Pan is designed for moisture analysis in laboratories or industrial settings. With a diameter of φ96 mm, they are made from quality, corrosion-resistant Aluminum. \u003cspan\u003eEach pack contains 50 pans, compatible with U.S. Solid USS-HMA1X and 2X series moisture analyzer and other moisture analyzer with 100 mm diameter. \u003c\/span\u003eThese pans provide a cost-effective, versatile, and durable solution for moisture analysis needs.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"ca65c0ed_1637561501\" class=\"powr-popup\"\u003e\u003cspan style=\"font-size: medium;\"\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv class=\"powr-popup\"\u003e\u003cspan style=\"font-size: medium;\"\u003eQuantity: 50\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv class=\"powr-popup\"\u003e\u003cspan style=\"font-size: medium;\"\u003eSize: φ100 mm\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv class=\"powr-popup\"\u003e\u003cspan style=\"font-size: medium;\"\u003eMaterial: Aluminum\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv class=\"powr-popup\"\u003e\u003cspan style=\"font-size: medium;\"\u003e \u003c\/span\u003e\u003c\/div\u003e","brand":"U.S. Solid","offers":[{"title":"Default Title","offer_id":46807770366207,"sku":"JFHMA00015","price":39.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/1_c8a5245c-0566-44cc-97a0-73d9e000aa72.png?v=1745386779"},{"product_id":"thermal-printer-for-u-s-solid-moisture-analyzers-rs232-transmission-160mm-s-80mm-width","title":"Thermal Printer for U.S. Solid Moisture Analyzers - RS232 Transmission - 160mm\/s - 80mm width","description":"\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e \u003cmeta content=\"width=device-width, initial-scale=1.0\" name=\"viewport\"\u003e\u003c\/p\u003e\n\u003cstyle\u003e\n   body{font-family:Arial,sans-serif;font-size:16px;line-height:26px;margin:0;padding:0;background-color:#fff;color:#000}.container{width:100%;margin:0;padding:0;background-color:#fff;box-shadow:none;border-radius:0}p,li{color:#000; margin:0; padding:0;}section{padding:0;margin:0}\n.section-title{font-family:Arial;font-size:22px;font-weight:700;margin-top:20px;margin-bottom:10px;text-align:left}\n.excel-table-container { \n        overflow-x: auto; \n        -webkit-overflow-scrolling: touch;\n    }\n    .excel-table-container table { \n        width: 100%; \n        table-layout: fixed;\n        border-collapse: collapse !important; \n        border-spacing: 0 !important; \n    }\n    .excel-table-container td { \n        border: none !important; border-bottom: 1px solid #ccc !important;\n        padding: 4px 8px !important; font-size: 16px;\n        line-height: 1.4 !important; vertical-align: middle;\n        word-wrap: break-word;\n    }\n    .excel-table-container tr:last-child td { border-bottom: none !important; }\n    @media (max-width: 600px) { .excel-table-container td { font-size: 14px; } }\n.picture-module .picture-row { display: flex; gap: 0.5%; align-items: stretch; }\n    .picture-module .picture-item { flex: 1 1 0; min-width: 0; }\n    .picture-module .picture-item img { width: 100%; height: auto; display: block; border: 0; }\n  \u003c\/style\u003e\n\u003cdiv class=\"container\"\u003e\n\u003cdiv class=\"picture-module\"\u003e\n\u003cdiv class=\"picture-row\"\u003e\n\u003cdiv class=\"picture-item\"\u003e\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHMA\/06B1.jpg\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp class=\"section-title\"\u003eIntroduction\u003c\/p\u003e\n\u003csection id=\"text\"\u003e\n\u003cp style=\"-qt-block-indent: 0; text-indent: 0px; margin: 0px;\"\u003e\u003cspan style=\"font-size: medium;\"\u003e Our cutting-edge thermal printer is optimized for quick, sharp, and energy-saving printing. It operates at a high printing speed of 160 mm\/s and is suitable for use with all U.S. Solid moisture analyzers. With an RS-232 port for effortless data transfer, it uses standard 3.15 inch (80 mm) width paper. The printer produces detailed printouts that include moisture content, weight, testing mode, temperature, and duration information. This thermal printer is an excellent solution for efficient, flexible, and comprehensive printing tasks. \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\u003cp class=\"section-title\"\u003eFeatures\u003c\/p\u003e\n\u003cdiv class=\"picture-module\"\u003e\n\u003cdiv class=\"picture-row\"\u003e\n\u003cdiv class=\"picture-item\"\u003e\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHMA\/F1.png\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp class=\"section-title\"\u003eApplications\u003c\/p\u003e\n\u003cdiv class=\"picture-module\"\u003e\n\u003cdiv class=\"picture-row\"\u003e\n\u003cdiv class=\"picture-item\"\u003e\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHMA\/A1.png\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp class=\"section-title\"\u003eSpecifications\u003c\/p\u003e\n\u003cdiv class=\"excel-table-container\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-weight: bold; text-align: center; background-color: #f0f0f0;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eUSS-HMA06\u003c\/td\u003e\n\u003ctd style=\"font-weight: bold; text-align: center; background-color: #f0f0f0;\"\u003ePrinting Type\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eThermal printing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-weight: bold; text-align: center; background-color: #f0f0f0;\"\u003ePrint Speed\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e6.3 inches\/s (160 mm\/s)\u003c\/td\u003e\n\u003ctd style=\"font-weight: bold; text-align: center; background-color: #f0f0f0;\"\u003ePaper Width\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e3.15 inches (80 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-weight: bold; text-align: center; background-color: #f0f0f0;\"\u003eInterface\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eRS232\u003c\/td\u003e\n\u003ctd style=\"font-weight: bold; text-align: center; background-color: #f0f0f0;\"\u003ePrint Resolution\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e203 DPI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-weight: bold; text-align: center; background-color: #f0f0f0;\"\u003eProduct Dimensions\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e6.61*5.2*6.35 inches\u003c\/td\u003e\n\u003ctd style=\"font-weight: bold; text-align: center; background-color: #f0f0f0;\"\u003eAdaptability\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eU.S. Solid moisture analyzers and balances\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp class=\"section-title\"\u003ePacking List\u003c\/p\u003e\n\u003cdiv class=\"excel-table-container\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\" colspan=\"2\"\u003ePrint Main Unit\u003c\/td\u003e\n\u003ctd style=\"text-align: right;\"\u003e1\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003eUnit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\" colspan=\"2\"\u003ePower Adapter (including power cable)\u003c\/td\u003e\n\u003ctd style=\"text-align: right;\"\u003e1\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003eSet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\" colspan=\"2\"\u003eUser Manual\u003c\/td\u003e\n\u003ctd style=\"text-align: right;\"\u003e1\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003ePiece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\" colspan=\"2\"\u003eRS232 Female to Male Data Connection Cable\u003c\/td\u003e\n\u003ctd style=\"text-align: right;\"\u003e1\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003eCable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\" colspan=\"2\"\u003eUSB Type-A to USB Type-B Data Connection Cable\u003c\/td\u003e\n\u003ctd style=\"text-align: right;\"\u003e1\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003eCable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\" colspan=\"2\"\u003eTest Paper\u003c\/td\u003e\n\u003ctd style=\"text-align: right;\"\u003e1\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003eRoll\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp class=\"section-title\"\u003eHow to Use\u003c\/p\u003e\n\u003cdiv class=\"picture-module\"\u003e\n\u003cdiv class=\"picture-row\"\u003e\n\u003cdiv class=\"picture-item\"\u003e\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHMA\/06H1.jpg\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"height: 10px; margin-top: 20px;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003csection id=\"text\"\u003e\n\u003cp style=\"-qt-block-indent: 0; text-indent: 0px; margin: 0px;\"\u003eDownload the user manual \u003ca href=\"http:\/\/file.ussolid.com\/content\/JFHMA\/USS-HMA06.pdf\" target=\"_blank\"\u003e \u003cspan style=\"text-decoration: underline; color: #2a82da;\"\u003e here \u003c\/span\u003e \u003c\/a\u003e .\u003c\/p\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e","brand":"U.S. Solid","offers":[{"title":"US","offer_id":47467078320383,"sku":"JFHMA00006","price":99.99,"currency_code":"USD","in_stock":true},{"title":"EU","offer_id":47467078353151,"sku":"JFHMA00006-EU","price":99.99,"currency_code":"USD","in_stock":true},{"title":"UK","offer_id":47467078385919,"sku":"JFHMA00006-UK","price":99.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/2_3_3604d46e-83be-4ffa-837a-e145316e1da4.jpg?v=1762481417"},{"product_id":"halogen-moisture-analyzer-40-230-c-drying-range-124-g-capacity-0-01-g-0-01-readability-5-in-touchscreen-rs232-moisture-balance","title":"Halogen Moisture Analyzer, 40-230 °C Drying Range, 124 g Capacity, 0.01 g\/0.01% Readability, 5-in Touchscreen, RS232 Moisture Balance","description":"\u003cstyle\u003e@media only screen and (max-width:600px){.desktop-only{display:none!important}.mobile-only{display:block!important}}@media only screen and (min-width:601px){.mobile-only{display:none!important}}\u003c\/style\u003e\n\u003cdiv class=\"desktop-only\"\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFVM\/coverimage.png\" alt=\"Halogen moisture analyzer cover image\" style=\"display: block; width: 100%; height: auto; border: 0;\"\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top: 0; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; line-height: 26px; margin: 10px 0 0; color: black; font-family: Arial;\"\u003eThe U.S. Solid USS-VM00001-124G halogen moisture analyzer provides a 40 to 230 deg C drying range for loss-on-drying methods, including procedures with setpoints above 200 deg C. It combines sample heating and weighing to calculate moisture and solids content for food powders, grain, feed, plastic pellets and other suitable laboratory materials.\u003cbr\u003e\u003cbr\u003eReview initial and final sample weights, dry basis and wet basis ratios, temperature and elapsed time. User permissions and custom sample identifiers help organize shared testing workflows. Select the temperature and endpoint for the material; mass loss can include volatile substances other than water, and readability describes display increments rather than measurement accuracy.\u003c\/p\u003e\n\u003cdiv style=\"flex: 1; padding: 0; font-family: Arial;\"\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFVM\/features.png\" alt=\"Halogen moisture analyzer features\" style=\"display: block; width: 100%; height: auto; border: 0;\"\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFVM\/applications.png\" alt=\"Halogen moisture analyzer applications\" style=\"display: block; width: 100%; height: auto; border: 0;\"\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n\u003ctable style=\"border-collapse: collapse; border: 0; width: 100%; font-family: Arial; overflow-x: auto; background-color: #ffffff;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0; background-color: #ffffff; color: black;\"\u003eUSS-VM00001-124G\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0; background-color: #f0f0f0; color: black;\"\u003eCapacity\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0; background-color: #ffffff; color: black;\"\u003e124 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0; background-color: #f0f0f0; color: black;\"\u003eWeighing Readability\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0; background-color: #ffffff; color: black;\"\u003e0.01 g\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0; background-color: #f0f0f0; color: black;\"\u003eMoisture Readability\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0; background-color: #ffffff; color: black;\"\u003e0.01%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0; background-color: #f0f0f0; color: black;\"\u003eWeighing Repeatability\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0; background-color: #ffffff; color: black;\"\u003eStandard deviation ≤3d (d=0.01 g)\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0; background-color: #f0f0f0; color: black;\"\u003eWeighing Sensor\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0; background-color: #ffffff; color: black;\"\u003eHBM strain gauge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0; background-color: #f0f0f0; color: black;\"\u003eNet Weight\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0; background-color: #ffffff; color: black;\"\u003e5.8 kg\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0; background-color: #f0f0f0; color: black;\"\u003eHeating Source\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0; background-color: #ffffff; color: black;\"\u003e350 W halogen lamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0; background-color: #f0f0f0; color: black;\"\u003eTemperature Setting Range\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0; background-color: #ffffff; color: black;\"\u003e40–230 °C (104–446 °F)\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0; background-color: #f0f0f0; color: black;\"\u003eTemperature Resolution \/ Setting Step\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0; background-color: #ffffff; color: black;\"\u003e0.1 °C \/ 0.1 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0; background-color: #f0f0f0; color: black;\"\u003eTemperature Sensor \/ Control\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0; background-color: #ffffff; color: black;\"\u003ePT-1000 \/ PID\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0; background-color: #f0f0f0; color: black;\"\u003ePower Supply\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0; background-color: #ffffff; color: black;\"\u003e110 V AC, 60 Hz, grounded US plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0; background-color: #f0f0f0; color: black;\"\u003eMaximum Instrument Input\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0; background-color: #ffffff; color: black;\"\u003e500 W\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0; background-color: #f0f0f0; color: black;\"\u003eDisplay\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0; background-color: #ffffff; color: black;\"\u003e5 in color touchscreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0; background-color: #f0f0f0; color: black;\"\u003eHeating Programs\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0; background-color: #ffffff; color: black;\"\u003eStandard, gentle, rapid, step\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0; background-color: #f0f0f0; color: black;\"\u003eStop Modes\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0; background-color: #ffffff; color: black;\"\u003eAutomatic, timed, manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0; background-color: #f0f0f0; color: black;\"\u003eTimed Mode Duration\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0; background-color: #ffffff; color: black;\"\u003e1–99 min; 1 second setting increments\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0; background-color: #f0f0f0; color: black;\"\u003eMethod Storage\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0; background-color: #ffffff; color: black;\"\u003e96 custom methods\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0; background-color: #f0f0f0; color: black;\"\u003eResult Storage\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0; background-color: #ffffff; color: black;\"\u003eUp to 2004 completed records\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0; background-color: #f0f0f0; color: black;\"\u003eUSB Record Backup\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0; background-color: #ffffff; color: black;\"\u003eUp to 2000 records per HTML export\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0; background-color: #f0f0f0; color: black;\"\u003eSample Pan Diameter\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0; background-color: #ffffff; color: black;\"\u003e90 mm\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0; background-color: #f0f0f0; color: black;\"\u003eHeating Chamber Height\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0; background-color: #ffffff; color: black;\"\u003e24.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0; background-color: #f0f0f0; color: black;\"\u003eInterfaces\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0; background-color: #ffffff; color: black;\"\u003eRS-232; USB record backup\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0; background-color: #f0f0f0; color: black;\"\u003eOperating Temperature\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0; background-color: #ffffff; color: black;\"\u003e1–38 °C; ideally 18–25 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0; background-color: #f0f0f0; color: black;\"\u003eDimensions\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0; background-color: #ffffff; color: black;\"\u003e23.4 × 35 × 20.5 cm\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0; background-color: #f0f0f0; color: black;\"\u003eCommon Series Features\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0; background-color: #ffffff; color: black;\"\u003eLive drying curve; user permissions; custom sample identification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"width: 100%; box-sizing: border-box; font-family: Arial; margin-top: 24px;\"\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin: 0 0 10px; color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"border-top: 1px solid #d9d9d9; border-bottom: 1px solid #d9d9d9;\"\u003e\n\u003cdiv style=\"padding: 12px 0; border-bottom: 1px solid #e5e5e5;\"\u003e\n\u003cp style=\"font-size: 16px; line-height: 24px; margin: 0 0 4px; color: black;\"\u003e\u003cstrong\u003eHow should the analyzer be prepared before a measurement?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; line-height: 24px; margin: 0; color: black;\"\u003ePlace it on a firm, level bench, install a clean and dry sample pan, allow at least 30 minutes of powered warm-up, and check or calibrate the weighing system as needed.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"padding: 12px 0; border-bottom: 1px solid #e5e5e5;\"\u003e\n\u003cp style=\"font-size: 16px; line-height: 24px; margin: 0 0 4px; color: black;\"\u003e\u003cstrong\u003eWhich heating mode should be selected?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; line-height: 24px; margin: 0; color: black;\"\u003eUse standard heating for routine samples, gentle heating for heat-sensitive materials, rapid heating for suitable high-moisture samples, and step heating when the validated method requires staged drying.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"padding: 12px 0; border-bottom: 1px solid #e5e5e5;\"\u003e\n\u003cp style=\"font-size: 16px; line-height: 24px; margin: 0 0 4px; color: black;\"\u003e\u003cstrong\u003eWhy can results vary between repeated tests?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; line-height: 24px; margin: 0; color: black;\"\u003eDifferences in sample uniformity, sample amount, preparation, starting chamber conditions, temperature, heating program, or endpoint can change the result. Keep these conditions consistent when comparing tests.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"padding: 12px 0; border-bottom: 1px solid #e5e5e5;\"\u003e\n\u003cp style=\"font-size: 16px; line-height: 24px; margin: 0 0 4px; color: black;\"\u003e\u003cstrong\u003eDoes the displayed moisture result measure water only?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; line-height: 24px; margin: 0; color: black;\"\u003eNot necessarily. The result is based on mass lost during heating and may include volatile substances other than water. Validate the method against an appropriate reference method when water-specific results are required.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"padding: 12px 0;\"\u003e\n\u003cp style=\"font-size: 16px; line-height: 24px; margin: 0 0 4px; color: black;\"\u003e\u003cstrong\u003eHow should the analyzer be cleaned?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; line-height: 24px; margin: 0; color: black;\"\u003eSwitch off, unplug, and allow the instrument to cool completely. Clean removable parts and exterior surfaces with a soft, lightly dampened lint-free cloth. Do not immerse the instrument, spray liquid onto it, or use abrasive cleaners or organic solvents.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin: 24px 0 10px; color: #9b1c1c;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"box-sizing: border-box; border-left: 5px solid #d97706; background-color: #fff7e6; padding: 14px 16px; color: black;\"\u003e\n\u003cul style=\"font-size: 16px; line-height: 24px; margin: 0; padding-left: 22px;\"\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003eUse only the specified 110 V AC, 60 Hz supply and a grounded US power cord. Do not operate the analyzer with damaged wiring or allow liquid to enter the housing or connectors.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003eThe heater, chamber, sample pan, and sample can remain hot after testing. Keep ventilation openings clear, maintain at least 1 m (39.4 in) of overhead clearance, and use suitable tools and heat protection.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003eDo not test explosive materials or samples that may react dangerously. Flammable, solvent-containing, toxic, or corrosive samples require a documented safety assessment and suitable extraction before testing.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003eDo not exceed the instrument capacity. Taring does not increase capacity, and a 100 g calibration weight must never be placed on a 62 g model.\u003c\/li\u003e\n\u003cli\u003eSwitch off, unplug, and allow the analyzer to cool before cleaning, moving, or connecting accessories. Do not open the housing or attempt internal repairs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mobile-only\"\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFVM\/coverimage.png\" alt=\"Halogen moisture analyzer cover image\" style=\"display: block; width: 100%; height: auto; border: 0;\"\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top: 0; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; line-height: 26px; margin: 0; color: black; font-family: Arial;\"\u003eThe U.S. Solid USS-VM00001-124G halogen moisture analyzer provides a 40 to 230 deg C drying range for loss-on-drying methods, including procedures with setpoints above 200 deg C. It combines sample heating and weighing to calculate moisture and solids content for food powders, grain, feed, plastic pellets and other suitable laboratory materials.\u003cbr\u003e\u003cbr\u003eReview initial and final sample weights, dry basis and wet basis ratios, temperature and elapsed time. User permissions and custom sample identifiers help organize shared testing workflows. Select the temperature and endpoint for the material; mass loss can include volatile substances other than water, and readability describes display increments rather than measurement accuracy.\u003c\/p\u003e\n\u003cdiv style=\"flex: 1; padding: 0; font-family: Arial;\"\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFVM\/features.png\" alt=\"Halogen moisture analyzer features\" style=\"display: block; width: 100%; height: auto; border: 0;\"\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFVM\/applications.png\" alt=\"Halogen moisture analyzer applications\" style=\"display: block; width: 100%; height: auto; border: 0;\"\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n\u003ctable style=\"border-collapse: collapse; border: 0; width: 100%; font-family: Arial; overflow-x: auto; background-color: #ffffff;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100px; text-align: left; padding: 5px; font-size: 14px; border: 0; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"width: 100px; text-align: left; padding: 5px; font-size: 14px; border: 0; background-color: #ffffff; color: black;\"\u003eUSS-VM00001-124G\u003c\/td\u003e\n\u003cth style=\"width: 100px; text-align: left; padding: 5px; font-size: 14px; border: 0; background-color: #f0f0f0; color: black;\"\u003eCapacity\u003c\/th\u003e\n\u003ctd style=\"width: 100px; text-align: left; padding: 5px; font-size: 14px; border: 0; background-color: #ffffff; color: black;\"\u003e124 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100px; text-align: left; padding: 5px; font-size: 14px; border: 0; background-color: #f0f0f0; color: black;\"\u003eWeighing Readability\u003c\/th\u003e\n\u003ctd style=\"width: 100px; text-align: left; padding: 5px; font-size: 14px; border: 0; background-color: #ffffff; color: black;\"\u003e0.01 g\u003c\/td\u003e\n\u003cth style=\"width: 100px; text-align: left; padding: 5px; font-size: 14px; border: 0; background-color: #f0f0f0; color: black;\"\u003eMoisture Readability\u003c\/th\u003e\n\u003ctd style=\"width: 100px; text-align: left; padding: 5px; font-size: 14px; border: 0; background-color: #ffffff; color: black;\"\u003e0.01%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100px; text-align: left; padding: 5px; font-size: 14px; border: 0; background-color: #f0f0f0; color: black;\"\u003eWeighing Repeatability\u003c\/th\u003e\n\u003ctd style=\"width: 100px; text-align: left; padding: 5px; font-size: 14px; border: 0; background-color: #ffffff; color: black;\"\u003eStandard deviation ≤3d (d=0.01 g)\u003c\/td\u003e\n\u003cth style=\"width: 100px; text-align: left; padding: 5px; font-size: 14px; border: 0; background-color: #f0f0f0; color: black;\"\u003eWeighing Sensor\u003c\/th\u003e\n\u003ctd style=\"width: 100px; text-align: left; padding: 5px; font-size: 14px; border: 0; background-color: #ffffff; color: black;\"\u003eHBM strain gauge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100px; text-align: left; padding: 5px; font-size: 14px; border: 0; background-color: #f0f0f0; color: black;\"\u003eNet Weight\u003c\/th\u003e\n\u003ctd style=\"width: 100px; text-align: left; padding: 5px; font-size: 14px; border: 0; background-color: #ffffff; color: black;\"\u003e5.8 kg\u003c\/td\u003e\n\u003cth style=\"width: 100px; text-align: left; padding: 5px; font-size: 14px; border: 0; background-color: #f0f0f0; color: black;\"\u003eHeating Source\u003c\/th\u003e\n\u003ctd style=\"width: 100px; text-align: left; padding: 5px; font-size: 14px; border: 0; background-color: #ffffff; color: black;\"\u003e350 W halogen lamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100px; text-align: left; padding: 5px; font-size: 14px; border: 0; background-color: #f0f0f0; color: black;\"\u003eTemperature Setting Range\u003c\/th\u003e\n\u003ctd style=\"width: 100px; text-align: left; padding: 5px; font-size: 14px; border: 0; background-color: #ffffff; color: black;\"\u003e40–230 °C (104–446 °F)\u003c\/td\u003e\n\u003cth style=\"width: 100px; text-align: left; padding: 5px; font-size: 14px; border: 0; background-color: #f0f0f0; color: black;\"\u003eTemperature Resolution \/ Setting Step\u003c\/th\u003e\n\u003ctd style=\"width: 100px; text-align: left; padding: 5px; font-size: 14px; border: 0; background-color: #ffffff; color: black;\"\u003e0.1 °C \/ 0.1 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100px; text-align: left; padding: 5px; font-size: 14px; border: 0; background-color: #f0f0f0; color: black;\"\u003eTemperature Sensor \/ Control\u003c\/th\u003e\n\u003ctd style=\"width: 100px; text-align: left; padding: 5px; font-size: 14px; border: 0; background-color: #ffffff; color: black;\"\u003ePT-1000 \/ PID\u003c\/td\u003e\n\u003cth style=\"width: 100px; text-align: left; padding: 5px; font-size: 14px; border: 0; background-color: #f0f0f0; color: black;\"\u003ePower Supply\u003c\/th\u003e\n\u003ctd style=\"width: 100px; text-align: left; padding: 5px; font-size: 14px; border: 0; background-color: #ffffff; color: black;\"\u003e110 V AC, 60 Hz, grounded US plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100px; text-align: left; padding: 5px; font-size: 14px; border: 0; background-color: #f0f0f0; color: black;\"\u003eMaximum Instrument Input\u003c\/th\u003e\n\u003ctd style=\"width: 100px; text-align: left; padding: 5px; font-size: 14px; border: 0; background-color: #ffffff; color: black;\"\u003e500 W\u003c\/td\u003e\n\u003cth style=\"width: 100px; text-align: left; padding: 5px; font-size: 14px; border: 0; background-color: #f0f0f0; color: black;\"\u003eDisplay\u003c\/th\u003e\n\u003ctd style=\"width: 100px; text-align: left; padding: 5px; font-size: 14px; border: 0; background-color: #ffffff; color: black;\"\u003e5 in color touchscreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100px; text-align: left; padding: 5px; font-size: 14px; border: 0; background-color: #f0f0f0; color: black;\"\u003eHeating Programs\u003c\/th\u003e\n\u003ctd style=\"width: 100px; text-align: left; padding: 5px; font-size: 14px; border: 0; background-color: #ffffff; color: black;\"\u003eStandard, gentle, rapid, step\u003c\/td\u003e\n\u003cth style=\"width: 100px; text-align: left; padding: 5px; font-size: 14px; border: 0; background-color: #f0f0f0; color: black;\"\u003eStop Modes\u003c\/th\u003e\n\u003ctd style=\"width: 100px; text-align: left; padding: 5px; font-size: 14px; border: 0; background-color: #ffffff; color: black;\"\u003eAutomatic, timed, manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100px; text-align: left; padding: 5px; font-size: 14px; border: 0; background-color: #f0f0f0; color: black;\"\u003eTimed Mode Duration\u003c\/th\u003e\n\u003ctd style=\"width: 100px; text-align: left; padding: 5px; font-size: 14px; border: 0; background-color: #ffffff; color: black;\"\u003e1–99 min; 1 second setting increments\u003c\/td\u003e\n\u003cth style=\"width: 100px; text-align: left; padding: 5px; font-size: 14px; border: 0; background-color: #f0f0f0; color: black;\"\u003eMethod Storage\u003c\/th\u003e\n\u003ctd style=\"width: 100px; text-align: left; padding: 5px; font-size: 14px; border: 0; background-color: #ffffff; color: black;\"\u003e96 custom methods\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100px; text-align: left; padding: 5px; font-size: 14px; border: 0; background-color: #f0f0f0; color: black;\"\u003eResult Storage\u003c\/th\u003e\n\u003ctd style=\"width: 100px; text-align: left; padding: 5px; font-size: 14px; border: 0; background-color: #ffffff; color: black;\"\u003eUp to 2004 completed records\u003c\/td\u003e\n\u003cth style=\"width: 100px; text-align: left; padding: 5px; font-size: 14px; border: 0; background-color: #f0f0f0; color: black;\"\u003eUSB Record Backup\u003c\/th\u003e\n\u003ctd style=\"width: 100px; text-align: left; padding: 5px; font-size: 14px; border: 0; background-color: #ffffff; color: black;\"\u003eUp to 2000 records per HTML export\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100px; text-align: left; padding: 5px; font-size: 14px; border: 0; background-color: #f0f0f0; color: black;\"\u003eSample Pan Diameter\u003c\/th\u003e\n\u003ctd style=\"width: 100px; text-align: left; padding: 5px; font-size: 14px; border: 0; background-color: #ffffff; color: black;\"\u003e90 mm\u003c\/td\u003e\n\u003cth style=\"width: 100px; text-align: left; padding: 5px; font-size: 14px; border: 0; background-color: #f0f0f0; color: black;\"\u003eHeating Chamber Height\u003c\/th\u003e\n\u003ctd style=\"width: 100px; text-align: left; padding: 5px; font-size: 14px; border: 0; background-color: #ffffff; color: black;\"\u003e24.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100px; text-align: left; padding: 5px; font-size: 14px; border: 0; background-color: #f0f0f0; color: black;\"\u003eInterfaces\u003c\/th\u003e\n\u003ctd style=\"width: 100px; text-align: left; padding: 5px; font-size: 14px; border: 0; background-color: #ffffff; color: black;\"\u003eRS-232; USB record backup\u003c\/td\u003e\n\u003cth style=\"width: 100px; text-align: left; padding: 5px; font-size: 14px; border: 0; background-color: #f0f0f0; color: black;\"\u003eOperating Temperature\u003c\/th\u003e\n\u003ctd style=\"width: 100px; text-align: left; padding: 5px; font-size: 14px; border: 0; background-color: #ffffff; color: black;\"\u003e1–38 °C; ideally 18–25 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 100px; text-align: left; padding: 5px; font-size: 14px; border: 0; background-color: #f0f0f0; color: black;\"\u003eDimensions\u003c\/th\u003e\n\u003ctd style=\"width: 100px; text-align: left; padding: 5px; font-size: 14px; border: 0; background-color: #ffffff; color: black;\"\u003e23.4 × 35 × 20.5 cm\u003c\/td\u003e\n\u003cth style=\"width: 100px; text-align: left; padding: 5px; font-size: 14px; border: 0; background-color: #f0f0f0; color: black;\"\u003eCommon Series Features\u003c\/th\u003e\n\u003ctd style=\"width: 100px; text-align: left; padding: 5px; font-size: 14px; border: 0; background-color: #ffffff; color: black;\"\u003eLive drying curve; user permissions; custom sample identification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"width: 100%; box-sizing: border-box; font-family: Arial; margin-top: 24px;\"\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin: 0 0 10px; color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"border-top: 1px solid #d9d9d9; border-bottom: 1px solid #d9d9d9;\"\u003e\n\u003cdiv style=\"padding: 12px 0; border-bottom: 1px solid #e5e5e5;\"\u003e\n\u003cp style=\"font-size: 16px; line-height: 24px; margin: 0 0 4px; color: black;\"\u003e\u003cstrong\u003eHow should the analyzer be prepared before a measurement?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; line-height: 24px; margin: 0; color: black;\"\u003ePlace it on a firm, level bench, install a clean and dry sample pan, allow at least 30 minutes of powered warm-up, and check or calibrate the weighing system as needed.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"padding: 12px 0; border-bottom: 1px solid #e5e5e5;\"\u003e\n\u003cp style=\"font-size: 16px; line-height: 24px; margin: 0 0 4px; color: black;\"\u003e\u003cstrong\u003eWhich heating mode should be selected?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; line-height: 24px; margin: 0; color: black;\"\u003eUse standard heating for routine samples, gentle heating for heat-sensitive materials, rapid heating for suitable high-moisture samples, and step heating when the validated method requires staged drying.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"padding: 12px 0; border-bottom: 1px solid #e5e5e5;\"\u003e\n\u003cp style=\"font-size: 16px; line-height: 24px; margin: 0 0 4px; color: black;\"\u003e\u003cstrong\u003eWhy can results vary between repeated tests?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; line-height: 24px; margin: 0; color: black;\"\u003eDifferences in sample uniformity, sample amount, preparation, starting chamber conditions, temperature, heating program, or endpoint can change the result. Keep these conditions consistent when comparing tests.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"padding: 12px 0; border-bottom: 1px solid #e5e5e5;\"\u003e\n\u003cp style=\"font-size: 16px; line-height: 24px; margin: 0 0 4px; color: black;\"\u003e\u003cstrong\u003eDoes the displayed moisture result measure water only?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; line-height: 24px; margin: 0; color: black;\"\u003eNot necessarily. The result is based on mass lost during heating and may include volatile substances other than water. Validate the method against an appropriate reference method when water-specific results are required.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"padding: 12px 0;\"\u003e\n\u003cp style=\"font-size: 16px; line-height: 24px; margin: 0 0 4px; color: black;\"\u003e\u003cstrong\u003eHow should the analyzer be cleaned?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; line-height: 24px; margin: 0; color: black;\"\u003eSwitch off, unplug, and allow the instrument to cool completely. Clean removable parts and exterior surfaces with a soft, lightly dampened lint-free cloth. Do not immerse the instrument, spray liquid onto it, or use abrasive cleaners or organic solvents.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin: 24px 0 10px; color: #9b1c1c;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"box-sizing: border-box; border-left: 5px solid #d97706; background-color: #fff7e6; padding: 14px 16px; color: black;\"\u003e\n\u003cul style=\"font-size: 16px; line-height: 24px; margin: 0; padding-left: 22px;\"\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003eUse only the specified 110 V AC, 60 Hz supply and a grounded US power cord. Do not operate the analyzer with damaged wiring or allow liquid to enter the housing or connectors.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003eThe heater, chamber, sample pan, and sample can remain hot after testing. Keep ventilation openings clear, maintain at least 1 m (39.4 in) of overhead clearance, and use suitable tools and heat protection.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003eDo not test explosive materials or samples that may react dangerously. Flammable, solvent-containing, toxic, or corrosive samples require a documented safety assessment and suitable extraction before testing.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003eDo not exceed the instrument capacity. Taring does not increase capacity, and a 100 g calibration weight must never be placed on a 62 g model.\u003c\/li\u003e\n\u003cli\u003eSwitch off, unplug, and allow the analyzer to cool before cleaning, moving, or connecting accessories. Do not open the housing or attempt internal repairs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"U.S. Solid","offers":[{"title":"Default Title","offer_id":49230399832319,"sku":"JFVM00001-124G","price":1539.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/1_fe6adb8d-1cae-4f83-b9e7-a9d5e6a7d9ea.png?v=1789626584"},{"product_id":"halogen-moisture-analyzer-40-230-c-drying-range-62-g-capacity-0-01-g-0-01-readability-5-in-touchscreen-rs232-moisture-balance","title":"Halogen Moisture Analyzer, 40-230 °C Drying Range, 62 g Capacity, 0.01 g\/0.01% Readability, 5-in Touchscreen, RS232 Moisture Balance","description":"\u003cbody\u003e\n\u003cstyle\u003e@media only screen and (max-width:600px){.desktop-only{display:none!important}.mobile-only{display:block!important}}@media only screen and (min-width:601px){.mobile-only{display:none!important}}\u003c\/style\u003e\n\u003cdiv class=\"desktop-only\"\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFVM\/coverimage.png\" alt=\"Halogen moisture analyzer cover image\" style=\"display:block;width:100%;height:auto;border:0;\"\u003e\u003cp style=\"font-size:22px;font-family:Arial;text-align:left;margin-top:0;margin-bottom:10px;color:black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:26px;margin:10px 0 0;color:black;font-family:Arial;\"\u003eThe U.S. Solid USS-VM00001-62G halogen moisture analyzer provides a 40 to 230 deg C drying range for loss-on-drying methods, including procedures with setpoints above 200 deg C. It combines sample heating and weighing to calculate moisture and solids content for food powders, grain, feed, plastic pellets and other suitable laboratory materials.\u003cbr\u003e\u003cbr\u003eReview initial and final sample weights, dry basis and wet basis ratios, temperature and elapsed time. User permissions and custom sample identifiers help organize shared testing workflows. Select the temperature and endpoint for the material; mass loss can include volatile substances other than water, and readability describes display increments rather than measurement accuracy.\u003c\/p\u003e\n\u003cdiv style=\"flex:1;padding:0;font-family:Arial;\"\u003e\n\u003cp style=\"font-size:22px;text-align:left;margin-top:20px;margin-bottom:10px;color:black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFVM\/features.png\" alt=\"Halogen moisture analyzer features\" style=\"display:block;width:100%;height:auto;border:0;\"\u003e\u003cp style=\"font-size:22px;text-align:left;margin-top:20px;margin-bottom:10px;color:black;\"\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFVM\/applications.png\" alt=\"Halogen moisture analyzer applications\" style=\"display:block;width:100%;height:auto;border:0;\"\u003e\u003cp style=\"font-size:22px;text-align:left;margin-top:20px;margin-bottom:10px;color:black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"width:100%;overflow-x:auto;\"\u003e\u003ctable style=\"border-collapse:collapse;border:0;width:100%;font-family:Arial;overflow-x:auto;background-color:#FFFFFF;\"\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003eUSS-VM00001-62G\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eCapacity\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e62 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eWeighing Readability\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e0.01 g\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eMoisture Readability\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e0.01%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eWeighing Repeatability\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003eStandard deviation ≤3d (d=0.01 g)\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eWeighing Sensor\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003eHBM strain gauge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eNet Weight\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e5.8 kg\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eHeating Source\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e350 W halogen lamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eTemperature Setting Range\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e40–230 °C (104–446 °F)\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eTemperature Resolution \/ Setting Step\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e0.1 °C \/ 0.1 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eTemperature Sensor \/ Control\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003ePT-1000 \/ PID\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003ePower Supply\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e110 V AC, 60 Hz, grounded US plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eMaximum Instrument Input\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e500 W\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eDisplay\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e5 in color touchscreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eHeating Programs\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003eStandard, gentle, rapid, step\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eStop Modes\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003eAutomatic, timed, manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eTimed Mode Duration\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e1–99 min; 1 second setting increments\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eMethod Storage\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e96 custom methods\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eResult Storage\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003eUp to 2004 completed records\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eUSB Record Backup\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003eUp to 2000 records per HTML export\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eSample Pan Diameter\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e90 mm\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eHeating Chamber Height\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e24.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eInterfaces\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003eRS-232; USB record backup\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eOperating Temperature\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e1–38 °C; ideally 18–25 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eDimensions\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e23.4 × 35 × 20.5 cm\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eCommon Series Features\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003eLive drying curve; user permissions; custom sample identification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cdiv data-section=\"faq-warning\" style=\"width:100%;box-sizing:border-box;font-family:Arial;margin-top:24px;\"\u003e\n  \u003cp style=\"font-size:22px;text-align:left;margin:0 0 10px;color:black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n  \u003cdiv style=\"border-top:1px solid #d9d9d9;border-bottom:1px solid #d9d9d9;\"\u003e\n    \u003cdiv style=\"padding:12px 0;border-bottom:1px solid #e5e5e5;\"\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0 0 4px;color:black;\"\u003e\u003cstrong\u003eHow should the analyzer be prepared before a measurement?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0;color:black;\"\u003ePlace it on a firm, level bench, install a clean and dry sample pan, allow at least 30 minutes of powered warm-up, and check or calibrate the weighing system as needed.\u003c\/p\u003e\n\u003c\/div\u003e\n    \u003cdiv style=\"padding:12px 0;border-bottom:1px solid #e5e5e5;\"\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0 0 4px;color:black;\"\u003e\u003cstrong\u003eWhich heating mode should be selected?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0;color:black;\"\u003eUse standard heating for routine samples, gentle heating for heat-sensitive materials, rapid heating for suitable high-moisture samples, and step heating when the validated method requires staged drying.\u003c\/p\u003e\n\u003c\/div\u003e\n    \u003cdiv style=\"padding:12px 0;border-bottom:1px solid #e5e5e5;\"\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0 0 4px;color:black;\"\u003e\u003cstrong\u003eWhy can results vary between repeated tests?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0;color:black;\"\u003eDifferences in sample uniformity, sample amount, preparation, starting chamber conditions, temperature, heating program, or endpoint can change the result. Keep these conditions consistent when comparing tests.\u003c\/p\u003e\n\u003c\/div\u003e\n    \u003cdiv style=\"padding:12px 0;border-bottom:1px solid #e5e5e5;\"\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0 0 4px;color:black;\"\u003e\u003cstrong\u003eDoes the displayed moisture result measure water only?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0;color:black;\"\u003eNot necessarily. The result is based on mass lost during heating and may include volatile substances other than water. Validate the method against an appropriate reference method when water-specific results are required.\u003c\/p\u003e\n\u003c\/div\u003e\n    \u003cdiv style=\"padding:12px 0;\"\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0 0 4px;color:black;\"\u003e\u003cstrong\u003eHow should the analyzer be cleaned?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0;color:black;\"\u003eSwitch off, unplug, and allow the instrument to cool completely. Clean removable parts and exterior surfaces with a soft, lightly dampened lint-free cloth. Do not immerse the instrument, spray liquid onto it, or use abrasive cleaners or organic solvents.\u003c\/p\u003e\n\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cp style=\"font-size:22px;text-align:left;margin:24px 0 10px;color:#9b1c1c;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n  \u003cdiv style=\"box-sizing:border-box;border-left:5px solid #d97706;background-color:#fff7e6;padding:14px 16px;color:black;\"\u003e\n    \u003cul style=\"font-size:16px;line-height:24px;margin:0;padding-left:22px;\"\u003e\n      \u003cli style=\"margin-bottom:8px;\"\u003eUse only the specified 110 V AC, 60 Hz supply and a grounded US power cord. Do not operate the analyzer with damaged wiring or allow liquid to enter the housing or connectors.\u003c\/li\u003e\n      \u003cli style=\"margin-bottom:8px;\"\u003eThe heater, chamber, sample pan, and sample can remain hot after testing. Keep ventilation openings clear, maintain at least 1 m (39.4 in) of overhead clearance, and use suitable tools and heat protection.\u003c\/li\u003e\n      \u003cli style=\"margin-bottom:8px;\"\u003eDo not test explosive materials or samples that may react dangerously. Flammable, solvent-containing, toxic, or corrosive samples require a documented safety assessment and suitable extraction before testing.\u003c\/li\u003e\n      \u003cli style=\"margin-bottom:8px;\"\u003eDo not exceed the instrument capacity. Taring does not increase capacity, and a 100 g calibration weight must never be placed on a 62 g model.\u003c\/li\u003e\n      \u003cli\u003eSwitch off, unplug, and allow the analyzer to cool before cleaning, moving, or connecting accessories. Do not open the housing or attempt internal repairs.\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mobile-only\"\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFVM\/coverimage.png\" alt=\"Halogen moisture analyzer cover image\" style=\"display:block;width:100%;height:auto;border:0;\"\u003e\u003cp style=\"font-size:22px;text-align:left;margin-top:0;margin-bottom:10px;color:black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:26px;margin:0;color:black;font-family:Arial;\"\u003eThe U.S. Solid USS-VM00001-62G halogen moisture analyzer provides a 40 to 230 deg C drying range for loss-on-drying methods, including procedures with setpoints above 200 deg C. It combines sample heating and weighing to calculate moisture and solids content for food powders, grain, feed, plastic pellets and other suitable laboratory materials.\u003cbr\u003e\u003cbr\u003eReview initial and final sample weights, dry basis and wet basis ratios, temperature and elapsed time. User permissions and custom sample identifiers help organize shared testing workflows. Select the temperature and endpoint for the material; mass loss can include volatile substances other than water, and readability describes display increments rather than measurement accuracy.\u003c\/p\u003e\n\u003cdiv style=\"flex:1;padding:0;font-family:Arial;\"\u003e\n\u003cp style=\"font-size:22px;text-align:left;margin-top:20px;margin-bottom:10px;color:black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFVM\/features.png\" alt=\"Halogen moisture analyzer features\" style=\"display:block;width:100%;height:auto;border:0;\"\u003e\u003cp style=\"font-size:22px;text-align:left;margin-top:20px;margin-bottom:10px;color:black;\"\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFVM\/applications.png\" alt=\"Halogen moisture analyzer applications\" style=\"display:block;width:100%;height:auto;border:0;\"\u003e\u003cp style=\"font-size:22px;text-align:left;margin-top:20px;margin-bottom:10px;color:black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"width:100%;overflow-x:auto;\"\u003e\u003ctable style=\"border-collapse:collapse;border:0;width:100%;font-family:Arial;overflow-x:auto;background-color:#FFFFFF;\"\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003eUSS-VM00001-62G\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eCapacity\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e62 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eWeighing Readability\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e0.01 g\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eMoisture Readability\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e0.01%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eWeighing Repeatability\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003eStandard deviation ≤3d (d=0.01 g)\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eWeighing Sensor\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003eHBM strain gauge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eNet Weight\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e5.8 kg\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eHeating Source\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e350 W halogen lamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eTemperature Setting Range\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e40–230 °C (104–446 °F)\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eTemperature Resolution \/ Setting Step\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e0.1 °C \/ 0.1 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eTemperature Sensor \/ Control\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003ePT-1000 \/ PID\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003ePower Supply\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e110 V AC, 60 Hz, grounded US plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eMaximum Instrument Input\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e500 W\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eDisplay\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e5 in color touchscreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eHeating Programs\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003eStandard, gentle, rapid, step\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eStop Modes\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003eAutomatic, timed, manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eTimed Mode Duration\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e1–99 min; 1 second setting increments\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eMethod Storage\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e96 custom methods\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eResult Storage\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003eUp to 2004 completed records\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eUSB Record Backup\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003eUp to 2000 records per HTML export\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eSample Pan Diameter\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e90 mm\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eHeating Chamber Height\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e24.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eInterfaces\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003eRS-232; USB record backup\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eOperating Temperature\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e1–38 °C; ideally 18–25 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eDimensions\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e23.4 × 35 × 20.5 cm\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eCommon Series Features\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003eLive drying curve; user permissions; custom sample identification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cdiv data-section=\"faq-warning\" style=\"width:100%;box-sizing:border-box;font-family:Arial;margin-top:24px;\"\u003e\n  \u003cp style=\"font-size:22px;text-align:left;margin:0 0 10px;color:black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n  \u003cdiv style=\"border-top:1px solid #d9d9d9;border-bottom:1px solid #d9d9d9;\"\u003e\n    \u003cdiv style=\"padding:12px 0;border-bottom:1px solid #e5e5e5;\"\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0 0 4px;color:black;\"\u003e\u003cstrong\u003eHow should the analyzer be prepared before a measurement?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0;color:black;\"\u003ePlace it on a firm, level bench, install a clean and dry sample pan, allow at least 30 minutes of powered warm-up, and check or calibrate the weighing system as needed.\u003c\/p\u003e\n\u003c\/div\u003e\n    \u003cdiv style=\"padding:12px 0;border-bottom:1px solid #e5e5e5;\"\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0 0 4px;color:black;\"\u003e\u003cstrong\u003eWhich heating mode should be selected?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0;color:black;\"\u003eUse standard heating for routine samples, gentle heating for heat-sensitive materials, rapid heating for suitable high-moisture samples, and step heating when the validated method requires staged drying.\u003c\/p\u003e\n\u003c\/div\u003e\n    \u003cdiv style=\"padding:12px 0;border-bottom:1px solid #e5e5e5;\"\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0 0 4px;color:black;\"\u003e\u003cstrong\u003eWhy can results vary between repeated tests?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0;color:black;\"\u003eDifferences in sample uniformity, sample amount, preparation, starting chamber conditions, temperature, heating program, or endpoint can change the result. Keep these conditions consistent when comparing tests.\u003c\/p\u003e\n\u003c\/div\u003e\n    \u003cdiv style=\"padding:12px 0;border-bottom:1px solid #e5e5e5;\"\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0 0 4px;color:black;\"\u003e\u003cstrong\u003eDoes the displayed moisture result measure water only?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0;color:black;\"\u003eNot necessarily. The result is based on mass lost during heating and may include volatile substances other than water. Validate the method against an appropriate reference method when water-specific results are required.\u003c\/p\u003e\n\u003c\/div\u003e\n    \u003cdiv style=\"padding:12px 0;\"\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0 0 4px;color:black;\"\u003e\u003cstrong\u003eHow should the analyzer be cleaned?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0;color:black;\"\u003eSwitch off, unplug, and allow the instrument to cool completely. Clean removable parts and exterior surfaces with a soft, lightly dampened lint-free cloth. Do not immerse the instrument, spray liquid onto it, or use abrasive cleaners or organic solvents.\u003c\/p\u003e\n\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cp style=\"font-size:22px;text-align:left;margin:24px 0 10px;color:#9b1c1c;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n  \u003cdiv style=\"box-sizing:border-box;border-left:5px solid #d97706;background-color:#fff7e6;padding:14px 16px;color:black;\"\u003e\n    \u003cul style=\"font-size:16px;line-height:24px;margin:0;padding-left:22px;\"\u003e\n      \u003cli style=\"margin-bottom:8px;\"\u003eUse only the specified 110 V AC, 60 Hz supply and a grounded US power cord. Do not operate the analyzer with damaged wiring or allow liquid to enter the housing or connectors.\u003c\/li\u003e\n      \u003cli style=\"margin-bottom:8px;\"\u003eThe heater, chamber, sample pan, and sample can remain hot after testing. Keep ventilation openings clear, maintain at least 1 m (39.4 in) of overhead clearance, and use suitable tools and heat protection.\u003c\/li\u003e\n      \u003cli style=\"margin-bottom:8px;\"\u003eDo not test explosive materials or samples that may react dangerously. Flammable, solvent-containing, toxic, or corrosive samples require a documented safety assessment and suitable extraction before testing.\u003c\/li\u003e\n      \u003cli style=\"margin-bottom:8px;\"\u003eDo not exceed the instrument capacity. Taring does not increase capacity, and a 100 g calibration weight must never be placed on a 62 g model.\u003c\/li\u003e\n      \u003cli\u003eSwitch off, unplug, and allow the analyzer to cool before cleaning, moving, or connecting accessories. Do not open the housing or attempt internal repairs.\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/body\u003e","brand":"U.S. Solid","offers":[{"title":"Default Title","offer_id":49230401208575,"sku":"JFVM00001-62G","price":1475.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/1_9c036e36-c82d-4a69-b046-97e50093dc58.png?v=1789626584"},{"product_id":"halogen-moisture-analyzer-40-230-c-drying-range-124-g-capacity-0-005-g-0-01-readability-5-in-touchscreen-rs232-moisture-balance","title":"Halogen Moisture Analyzer, 40-230 °C Drying Range, 124 g Capacity, 0.005 g\/0.01% Readability, 5-in Touchscreen, RS232 Moisture Balance","description":"\u003cbody\u003e\n\u003cstyle\u003e@media only screen and (max-width:600px){.desktop-only{display:none!important}.mobile-only{display:block!important}}@media only screen and (min-width:601px){.mobile-only{display:none!important}}\u003c\/style\u003e\n\u003cdiv class=\"desktop-only\"\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFVM\/coverimage.png\" alt=\"Halogen moisture analyzer cover image\" style=\"display:block;width:100%;height:auto;border:0;\"\u003e\u003cp style=\"font-size:22px;font-family:Arial;text-align:left;margin-top:0;margin-bottom:10px;color:black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:26px;margin:10px 0 0;color:black;font-family:Arial;\"\u003eThe U.S. Solid USS-VM00002-124G halogen moisture analyzer provides a 40 to 230 deg C drying range for loss-on-drying methods, including procedures with setpoints above 200 deg C. It combines sample heating and weighing to calculate moisture and solids content for food powders, grain, feed, plastic pellets and other suitable laboratory materials.\u003cbr\u003e\u003cbr\u003eReview initial and final sample weights, dry basis and wet basis ratios, temperature and elapsed time. User permissions and custom sample identifiers help organize shared testing workflows. Select the temperature and endpoint for the material; mass loss can include volatile substances other than water, and readability describes display increments rather than measurement accuracy.\u003c\/p\u003e\n\u003cdiv style=\"flex:1;padding:0;font-family:Arial;\"\u003e\n\u003cp style=\"font-size:22px;text-align:left;margin-top:20px;margin-bottom:10px;color:black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFVM\/features.png\" alt=\"Halogen moisture analyzer features\" style=\"display:block;width:100%;height:auto;border:0;\"\u003e\u003cp style=\"font-size:22px;text-align:left;margin-top:20px;margin-bottom:10px;color:black;\"\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFVM\/applications.png\" alt=\"Halogen moisture analyzer applications\" style=\"display:block;width:100%;height:auto;border:0;\"\u003e\u003cp style=\"font-size:22px;text-align:left;margin-top:20px;margin-bottom:10px;color:black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"width:100%;overflow-x:auto;\"\u003e\u003ctable style=\"border-collapse:collapse;border:0;width:100%;font-family:Arial;overflow-x:auto;background-color:#FFFFFF;\"\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003eUSS-VM00002-124G\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eCapacity\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e124 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eWeighing Readability\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e0.005 g\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eMoisture Readability\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e0.01%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eWeighing Repeatability\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003eStandard deviation ≤3d (d=0.005 g)\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eWeighing Sensor\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003eHBM strain gauge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eNet Weight\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e5.8 kg\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eHeating Source\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e350 W halogen lamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eTemperature Setting Range\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e40–230 °C (104–446 °F)\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eTemperature Resolution \/ Setting Step\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e0.1 °C \/ 0.1 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eTemperature Sensor \/ Control\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003ePT-1000 \/ PID\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003ePower Supply\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e110 V AC, 60 Hz, grounded US plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eMaximum Instrument Input\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e500 W\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eDisplay\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e5 in color touchscreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eHeating Programs\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003eStandard, gentle, rapid, step\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eStop Modes\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003eAutomatic, timed, manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eTimed Mode Duration\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e1–99 min; 1 second setting increments\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eMethod Storage\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e96 custom methods\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eResult Storage\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003eUp to 2004 completed records\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eUSB Record Backup\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003eUp to 2000 records per HTML export\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eSample Pan Diameter\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e90 mm\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eHeating Chamber Height\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e24.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eInterfaces\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003eRS-232; USB record backup\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eOperating Temperature\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e1–38 °C; ideally 18–25 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eDimensions\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e23.4 × 35 × 20.5 cm\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eCommon Series Features\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003eLive drying curve; user permissions; custom sample identification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cdiv data-section=\"faq-warning\" style=\"width:100%;box-sizing:border-box;font-family:Arial;margin-top:24px;\"\u003e\n  \u003cp style=\"font-size:22px;text-align:left;margin:0 0 10px;color:black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n  \u003cdiv style=\"border-top:1px solid #d9d9d9;border-bottom:1px solid #d9d9d9;\"\u003e\n    \u003cdiv style=\"padding:12px 0;border-bottom:1px solid #e5e5e5;\"\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0 0 4px;color:black;\"\u003e\u003cstrong\u003eHow should the analyzer be prepared before a measurement?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0;color:black;\"\u003ePlace it on a firm, level bench, install a clean and dry sample pan, allow at least 30 minutes of powered warm-up, and check or calibrate the weighing system as needed.\u003c\/p\u003e\n\u003c\/div\u003e\n    \u003cdiv style=\"padding:12px 0;border-bottom:1px solid #e5e5e5;\"\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0 0 4px;color:black;\"\u003e\u003cstrong\u003eWhich heating mode should be selected?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0;color:black;\"\u003eUse standard heating for routine samples, gentle heating for heat-sensitive materials, rapid heating for suitable high-moisture samples, and step heating when the validated method requires staged drying.\u003c\/p\u003e\n\u003c\/div\u003e\n    \u003cdiv style=\"padding:12px 0;border-bottom:1px solid #e5e5e5;\"\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0 0 4px;color:black;\"\u003e\u003cstrong\u003eWhy can results vary between repeated tests?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0;color:black;\"\u003eDifferences in sample uniformity, sample amount, preparation, starting chamber conditions, temperature, heating program, or endpoint can change the result. Keep these conditions consistent when comparing tests.\u003c\/p\u003e\n\u003c\/div\u003e\n    \u003cdiv style=\"padding:12px 0;border-bottom:1px solid #e5e5e5;\"\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0 0 4px;color:black;\"\u003e\u003cstrong\u003eDoes the displayed moisture result measure water only?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0;color:black;\"\u003eNot necessarily. The result is based on mass lost during heating and may include volatile substances other than water. Validate the method against an appropriate reference method when water-specific results are required.\u003c\/p\u003e\n\u003c\/div\u003e\n    \u003cdiv style=\"padding:12px 0;\"\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0 0 4px;color:black;\"\u003e\u003cstrong\u003eHow should the analyzer be cleaned?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0;color:black;\"\u003eSwitch off, unplug, and allow the instrument to cool completely. Clean removable parts and exterior surfaces with a soft, lightly dampened lint-free cloth. Do not immerse the instrument, spray liquid onto it, or use abrasive cleaners or organic solvents.\u003c\/p\u003e\n\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cp style=\"font-size:22px;text-align:left;margin:24px 0 10px;color:#9b1c1c;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n  \u003cdiv style=\"box-sizing:border-box;border-left:5px solid #d97706;background-color:#fff7e6;padding:14px 16px;color:black;\"\u003e\n    \u003cul style=\"font-size:16px;line-height:24px;margin:0;padding-left:22px;\"\u003e\n      \u003cli style=\"margin-bottom:8px;\"\u003eUse only the specified 110 V AC, 60 Hz supply and a grounded US power cord. Do not operate the analyzer with damaged wiring or allow liquid to enter the housing or connectors.\u003c\/li\u003e\n      \u003cli style=\"margin-bottom:8px;\"\u003eThe heater, chamber, sample pan, and sample can remain hot after testing. Keep ventilation openings clear, maintain at least 1 m (39.4 in) of overhead clearance, and use suitable tools and heat protection.\u003c\/li\u003e\n      \u003cli style=\"margin-bottom:8px;\"\u003eDo not test explosive materials or samples that may react dangerously. Flammable, solvent-containing, toxic, or corrosive samples require a documented safety assessment and suitable extraction before testing.\u003c\/li\u003e\n      \u003cli style=\"margin-bottom:8px;\"\u003eDo not exceed the instrument capacity. Taring does not increase capacity, and a 100 g calibration weight must never be placed on a 62 g model.\u003c\/li\u003e\n      \u003cli\u003eSwitch off, unplug, and allow the analyzer to cool before cleaning, moving, or connecting accessories. Do not open the housing or attempt internal repairs.\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mobile-only\"\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFVM\/coverimage.png\" alt=\"Halogen moisture analyzer cover image\" style=\"display:block;width:100%;height:auto;border:0;\"\u003e\u003cp style=\"font-size:22px;text-align:left;margin-top:0;margin-bottom:10px;color:black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:26px;margin:0;color:black;font-family:Arial;\"\u003eThe U.S. Solid USS-VM00002-124G halogen moisture analyzer provides a 40 to 230 deg C drying range for loss-on-drying methods, including procedures with setpoints above 200 deg C. It combines sample heating and weighing to calculate moisture and solids content for food powders, grain, feed, plastic pellets and other suitable laboratory materials.\u003cbr\u003e\u003cbr\u003eReview initial and final sample weights, dry basis and wet basis ratios, temperature and elapsed time. User permissions and custom sample identifiers help organize shared testing workflows. Select the temperature and endpoint for the material; mass loss can include volatile substances other than water, and readability describes display increments rather than measurement accuracy.\u003c\/p\u003e\n\u003cdiv style=\"flex:1;padding:0;font-family:Arial;\"\u003e\n\u003cp style=\"font-size:22px;text-align:left;margin-top:20px;margin-bottom:10px;color:black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFVM\/features.png\" alt=\"Halogen moisture analyzer features\" style=\"display:block;width:100%;height:auto;border:0;\"\u003e\u003cp style=\"font-size:22px;text-align:left;margin-top:20px;margin-bottom:10px;color:black;\"\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFVM\/applications.png\" alt=\"Halogen moisture analyzer applications\" style=\"display:block;width:100%;height:auto;border:0;\"\u003e\u003cp style=\"font-size:22px;text-align:left;margin-top:20px;margin-bottom:10px;color:black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"width:100%;overflow-x:auto;\"\u003e\u003ctable style=\"border-collapse:collapse;border:0;width:100%;font-family:Arial;overflow-x:auto;background-color:#FFFFFF;\"\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003eUSS-VM00002-124G\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eCapacity\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e124 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eWeighing Readability\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e0.005 g\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eMoisture Readability\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e0.01%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eWeighing Repeatability\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003eStandard deviation ≤3d (d=0.005 g)\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eWeighing Sensor\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003eHBM strain gauge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eNet Weight\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e5.8 kg\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eHeating Source\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e350 W halogen lamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eTemperature Setting Range\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e40–230 °C (104–446 °F)\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eTemperature Resolution \/ Setting Step\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e0.1 °C \/ 0.1 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eTemperature Sensor \/ Control\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003ePT-1000 \/ PID\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003ePower Supply\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e110 V AC, 60 Hz, grounded US plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eMaximum Instrument Input\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e500 W\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eDisplay\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e5 in color touchscreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eHeating Programs\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003eStandard, gentle, rapid, step\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eStop Modes\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003eAutomatic, timed, manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eTimed Mode Duration\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e1–99 min; 1 second setting increments\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eMethod Storage\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e96 custom methods\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eResult Storage\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003eUp to 2004 completed records\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eUSB Record Backup\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003eUp to 2000 records per HTML export\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eSample Pan Diameter\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e90 mm\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eHeating Chamber Height\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e24.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eInterfaces\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003eRS-232; USB record backup\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eOperating Temperature\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e1–38 °C; ideally 18–25 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eDimensions\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e23.4 × 35 × 20.5 cm\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eCommon Series Features\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003eLive drying curve; user permissions; custom sample identification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cdiv data-section=\"faq-warning\" style=\"width:100%;box-sizing:border-box;font-family:Arial;margin-top:24px;\"\u003e\n  \u003cp style=\"font-size:22px;text-align:left;margin:0 0 10px;color:black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n  \u003cdiv style=\"border-top:1px solid #d9d9d9;border-bottom:1px solid #d9d9d9;\"\u003e\n    \u003cdiv style=\"padding:12px 0;border-bottom:1px solid #e5e5e5;\"\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0 0 4px;color:black;\"\u003e\u003cstrong\u003eHow should the analyzer be prepared before a measurement?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0;color:black;\"\u003ePlace it on a firm, level bench, install a clean and dry sample pan, allow at least 30 minutes of powered warm-up, and check or calibrate the weighing system as needed.\u003c\/p\u003e\n\u003c\/div\u003e\n    \u003cdiv style=\"padding:12px 0;border-bottom:1px solid #e5e5e5;\"\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0 0 4px;color:black;\"\u003e\u003cstrong\u003eWhich heating mode should be selected?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0;color:black;\"\u003eUse standard heating for routine samples, gentle heating for heat-sensitive materials, rapid heating for suitable high-moisture samples, and step heating when the validated method requires staged drying.\u003c\/p\u003e\n\u003c\/div\u003e\n    \u003cdiv style=\"padding:12px 0;border-bottom:1px solid #e5e5e5;\"\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0 0 4px;color:black;\"\u003e\u003cstrong\u003eWhy can results vary between repeated tests?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0;color:black;\"\u003eDifferences in sample uniformity, sample amount, preparation, starting chamber conditions, temperature, heating program, or endpoint can change the result. Keep these conditions consistent when comparing tests.\u003c\/p\u003e\n\u003c\/div\u003e\n    \u003cdiv style=\"padding:12px 0;border-bottom:1px solid #e5e5e5;\"\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0 0 4px;color:black;\"\u003e\u003cstrong\u003eDoes the displayed moisture result measure water only?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0;color:black;\"\u003eNot necessarily. The result is based on mass lost during heating and may include volatile substances other than water. Validate the method against an appropriate reference method when water-specific results are required.\u003c\/p\u003e\n\u003c\/div\u003e\n    \u003cdiv style=\"padding:12px 0;\"\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0 0 4px;color:black;\"\u003e\u003cstrong\u003eHow should the analyzer be cleaned?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0;color:black;\"\u003eSwitch off, unplug, and allow the instrument to cool completely. Clean removable parts and exterior surfaces with a soft, lightly dampened lint-free cloth. Do not immerse the instrument, spray liquid onto it, or use abrasive cleaners or organic solvents.\u003c\/p\u003e\n\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cp style=\"font-size:22px;text-align:left;margin:24px 0 10px;color:#9b1c1c;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n  \u003cdiv style=\"box-sizing:border-box;border-left:5px solid #d97706;background-color:#fff7e6;padding:14px 16px;color:black;\"\u003e\n    \u003cul style=\"font-size:16px;line-height:24px;margin:0;padding-left:22px;\"\u003e\n      \u003cli style=\"margin-bottom:8px;\"\u003eUse only the specified 110 V AC, 60 Hz supply and a grounded US power cord. Do not operate the analyzer with damaged wiring or allow liquid to enter the housing or connectors.\u003c\/li\u003e\n      \u003cli style=\"margin-bottom:8px;\"\u003eThe heater, chamber, sample pan, and sample can remain hot after testing. Keep ventilation openings clear, maintain at least 1 m (39.4 in) of overhead clearance, and use suitable tools and heat protection.\u003c\/li\u003e\n      \u003cli style=\"margin-bottom:8px;\"\u003eDo not test explosive materials or samples that may react dangerously. Flammable, solvent-containing, toxic, or corrosive samples require a documented safety assessment and suitable extraction before testing.\u003c\/li\u003e\n      \u003cli style=\"margin-bottom:8px;\"\u003eDo not exceed the instrument capacity. Taring does not increase capacity, and a 100 g calibration weight must never be placed on a 62 g model.\u003c\/li\u003e\n      \u003cli\u003eSwitch off, unplug, and allow the analyzer to cool before cleaning, moving, or connecting accessories. Do not open the housing or attempt internal repairs.\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/body\u003e","brand":"U.S. Solid","offers":[{"title":"Default Title","offer_id":49230403240191,"sku":"JFVM00002-124G","price":1636.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/1_bba11117-e888-4968-8379-7f32a0c7ec75.png?v=1789626584"},{"product_id":"halogen-moisture-analyzer-40-230-c-drying-range-62-g-capacity-0-005-g-0-01-readability-5-in-touchscreen-rs232-moisture-balance","title":"Halogen Moisture Analyzer, 40-230 °C Drying Range, 62 g Capacity, 0.005 g\/0.01% Readability, 5-in Touchscreen, RS232 Moisture Balance","description":"\u003cbody\u003e\n\u003cstyle\u003e@media only screen and (max-width:600px){.desktop-only{display:none!important}.mobile-only{display:block!important}}@media only screen and (min-width:601px){.mobile-only{display:none!important}}\u003c\/style\u003e\n\u003cdiv class=\"desktop-only\"\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFVM\/coverimage.png\" alt=\"Halogen moisture analyzer cover image\" style=\"display:block;width:100%;height:auto;border:0;\"\u003e\u003cp style=\"font-size:22px;font-family:Arial;text-align:left;margin-top:0;margin-bottom:10px;color:black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:26px;margin:10px 0 0;color:black;font-family:Arial;\"\u003eThe U.S. Solid USS-VM00002-62G halogen moisture analyzer provides a 40 to 230 deg C drying range for loss-on-drying methods, including procedures with setpoints above 200 deg C. It combines sample heating and weighing to calculate moisture and solids content for food powders, grain, feed, plastic pellets and other suitable laboratory materials.\u003cbr\u003e\u003cbr\u003eReview initial and final sample weights, dry basis and wet basis ratios, temperature and elapsed time. User permissions and custom sample identifiers help organize shared testing workflows. Select the temperature and endpoint for the material; mass loss can include volatile substances other than water, and readability describes display increments rather than measurement accuracy.\u003c\/p\u003e\n\u003cdiv style=\"flex:1;padding:0;font-family:Arial;\"\u003e\n\u003cp style=\"font-size:22px;text-align:left;margin-top:20px;margin-bottom:10px;color:black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFVM\/features.png\" alt=\"Halogen moisture analyzer features\" style=\"display:block;width:100%;height:auto;border:0;\"\u003e\u003cp style=\"font-size:22px;text-align:left;margin-top:20px;margin-bottom:10px;color:black;\"\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFVM\/applications.png\" alt=\"Halogen moisture analyzer applications\" style=\"display:block;width:100%;height:auto;border:0;\"\u003e\u003cp style=\"font-size:22px;text-align:left;margin-top:20px;margin-bottom:10px;color:black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"width:100%;overflow-x:auto;\"\u003e\u003ctable style=\"border-collapse:collapse;border:0;width:100%;font-family:Arial;overflow-x:auto;background-color:#FFFFFF;\"\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003eUSS-VM00002-62G\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eCapacity\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e62 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eWeighing Readability\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e0.005 g\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eMoisture Readability\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e0.01%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eWeighing Repeatability\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003eStandard deviation ≤3d (d=0.005 g)\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eWeighing Sensor\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003eHBM strain gauge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eNet Weight\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e5.8 kg\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eHeating Source\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e350 W halogen lamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eTemperature Setting Range\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e40–230 °C (104–446 °F)\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eTemperature Resolution \/ Setting Step\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e0.1 °C \/ 0.1 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eTemperature Sensor \/ Control\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003ePT-1000 \/ PID\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003ePower Supply\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e110 V AC, 60 Hz, grounded US plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eMaximum Instrument Input\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e500 W\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eDisplay\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e5 in color touchscreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eHeating Programs\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003eStandard, gentle, rapid, step\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eStop Modes\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003eAutomatic, timed, manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eTimed Mode Duration\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e1–99 min; 1 second setting increments\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eMethod Storage\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e96 custom methods\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eResult Storage\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003eUp to 2004 completed records\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eUSB Record Backup\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003eUp to 2000 records per HTML export\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eSample Pan Diameter\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e90 mm\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eHeating Chamber Height\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e24.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eInterfaces\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003eRS-232; USB record backup\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eOperating Temperature\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e1–38 °C; ideally 18–25 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eDimensions\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e23.4 × 35 × 20.5 cm\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eCommon Series Features\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003eLive drying curve; user permissions; custom sample identification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cdiv data-section=\"faq-warning\" style=\"width:100%;box-sizing:border-box;font-family:Arial;margin-top:24px;\"\u003e\n  \u003cp style=\"font-size:22px;text-align:left;margin:0 0 10px;color:black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n  \u003cdiv style=\"border-top:1px solid #d9d9d9;border-bottom:1px solid #d9d9d9;\"\u003e\n    \u003cdiv style=\"padding:12px 0;border-bottom:1px solid #e5e5e5;\"\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0 0 4px;color:black;\"\u003e\u003cstrong\u003eHow should the analyzer be prepared before a measurement?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0;color:black;\"\u003ePlace it on a firm, level bench, install a clean and dry sample pan, allow at least 30 minutes of powered warm-up, and check or calibrate the weighing system as needed.\u003c\/p\u003e\n\u003c\/div\u003e\n    \u003cdiv style=\"padding:12px 0;border-bottom:1px solid #e5e5e5;\"\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0 0 4px;color:black;\"\u003e\u003cstrong\u003eWhich heating mode should be selected?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0;color:black;\"\u003eUse standard heating for routine samples, gentle heating for heat-sensitive materials, rapid heating for suitable high-moisture samples, and step heating when the validated method requires staged drying.\u003c\/p\u003e\n\u003c\/div\u003e\n    \u003cdiv style=\"padding:12px 0;border-bottom:1px solid #e5e5e5;\"\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0 0 4px;color:black;\"\u003e\u003cstrong\u003eWhy can results vary between repeated tests?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0;color:black;\"\u003eDifferences in sample uniformity, sample amount, preparation, starting chamber conditions, temperature, heating program, or endpoint can change the result. Keep these conditions consistent when comparing tests.\u003c\/p\u003e\n\u003c\/div\u003e\n    \u003cdiv style=\"padding:12px 0;border-bottom:1px solid #e5e5e5;\"\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0 0 4px;color:black;\"\u003e\u003cstrong\u003eDoes the displayed moisture result measure water only?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0;color:black;\"\u003eNot necessarily. The result is based on mass lost during heating and may include volatile substances other than water. Validate the method against an appropriate reference method when water-specific results are required.\u003c\/p\u003e\n\u003c\/div\u003e\n    \u003cdiv style=\"padding:12px 0;\"\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0 0 4px;color:black;\"\u003e\u003cstrong\u003eHow should the analyzer be cleaned?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0;color:black;\"\u003eSwitch off, unplug, and allow the instrument to cool completely. Clean removable parts and exterior surfaces with a soft, lightly dampened lint-free cloth. Do not immerse the instrument, spray liquid onto it, or use abrasive cleaners or organic solvents.\u003c\/p\u003e\n\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cp style=\"font-size:22px;text-align:left;margin:24px 0 10px;color:#9b1c1c;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n  \u003cdiv style=\"box-sizing:border-box;border-left:5px solid #d97706;background-color:#fff7e6;padding:14px 16px;color:black;\"\u003e\n    \u003cul style=\"font-size:16px;line-height:24px;margin:0;padding-left:22px;\"\u003e\n      \u003cli style=\"margin-bottom:8px;\"\u003eUse only the specified 110 V AC, 60 Hz supply and a grounded US power cord. Do not operate the analyzer with damaged wiring or allow liquid to enter the housing or connectors.\u003c\/li\u003e\n      \u003cli style=\"margin-bottom:8px;\"\u003eThe heater, chamber, sample pan, and sample can remain hot after testing. Keep ventilation openings clear, maintain at least 1 m (39.4 in) of overhead clearance, and use suitable tools and heat protection.\u003c\/li\u003e\n      \u003cli style=\"margin-bottom:8px;\"\u003eDo not test explosive materials or samples that may react dangerously. Flammable, solvent-containing, toxic, or corrosive samples require a documented safety assessment and suitable extraction before testing.\u003c\/li\u003e\n      \u003cli style=\"margin-bottom:8px;\"\u003eDo not exceed the instrument capacity. Taring does not increase capacity, and a 100 g calibration weight must never be placed on a 62 g model.\u003c\/li\u003e\n      \u003cli\u003eSwitch off, unplug, and allow the analyzer to cool before cleaning, moving, or connecting accessories. Do not open the housing or attempt internal repairs.\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mobile-only\"\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFVM\/coverimage.png\" alt=\"Halogen moisture analyzer cover image\" style=\"display:block;width:100%;height:auto;border:0;\"\u003e\u003cp style=\"font-size:22px;text-align:left;margin-top:0;margin-bottom:10px;color:black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:26px;margin:0;color:black;font-family:Arial;\"\u003eThe U.S. Solid USS-VM00002-62G halogen moisture analyzer provides a 40 to 230 deg C drying range for loss-on-drying methods, including procedures with setpoints above 200 deg C. It combines sample heating and weighing to calculate moisture and solids content for food powders, grain, feed, plastic pellets and other suitable laboratory materials.\u003cbr\u003e\u003cbr\u003eReview initial and final sample weights, dry basis and wet basis ratios, temperature and elapsed time. User permissions and custom sample identifiers help organize shared testing workflows. Select the temperature and endpoint for the material; mass loss can include volatile substances other than water, and readability describes display increments rather than measurement accuracy.\u003c\/p\u003e\n\u003cdiv style=\"flex:1;padding:0;font-family:Arial;\"\u003e\n\u003cp style=\"font-size:22px;text-align:left;margin-top:20px;margin-bottom:10px;color:black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFVM\/features.png\" alt=\"Halogen moisture analyzer features\" style=\"display:block;width:100%;height:auto;border:0;\"\u003e\u003cp style=\"font-size:22px;text-align:left;margin-top:20px;margin-bottom:10px;color:black;\"\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFVM\/applications.png\" alt=\"Halogen moisture analyzer applications\" style=\"display:block;width:100%;height:auto;border:0;\"\u003e\u003cp style=\"font-size:22px;text-align:left;margin-top:20px;margin-bottom:10px;color:black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"width:100%;overflow-x:auto;\"\u003e\u003ctable style=\"border-collapse:collapse;border:0;width:100%;font-family:Arial;overflow-x:auto;background-color:#FFFFFF;\"\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003eUSS-VM00002-62G\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eCapacity\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e62 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eWeighing Readability\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e0.005 g\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eMoisture Readability\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e0.01%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eWeighing Repeatability\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003eStandard deviation ≤3d (d=0.005 g)\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eWeighing Sensor\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003eHBM strain gauge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eNet Weight\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e5.8 kg\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eHeating Source\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e350 W halogen lamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eTemperature Setting Range\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e40–230 °C (104–446 °F)\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eTemperature Resolution \/ Setting Step\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e0.1 °C \/ 0.1 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eTemperature Sensor \/ Control\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003ePT-1000 \/ PID\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003ePower Supply\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e110 V AC, 60 Hz, grounded US plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eMaximum Instrument Input\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e500 W\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eDisplay\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e5 in color touchscreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eHeating Programs\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003eStandard, gentle, rapid, step\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eStop Modes\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003eAutomatic, timed, manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eTimed Mode Duration\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e1–99 min; 1 second setting increments\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eMethod Storage\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e96 custom methods\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eResult Storage\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003eUp to 2004 completed records\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eUSB Record Backup\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003eUp to 2000 records per HTML export\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eSample Pan Diameter\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e90 mm\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eHeating Chamber Height\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e24.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eInterfaces\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003eRS-232; USB record backup\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eOperating Temperature\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e1–38 °C; ideally 18–25 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eDimensions\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e23.4 × 35 × 20.5 cm\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eCommon Series Features\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003eLive drying curve; user permissions; custom sample identification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cdiv data-section=\"faq-warning\" style=\"width:100%;box-sizing:border-box;font-family:Arial;margin-top:24px;\"\u003e\n  \u003cp style=\"font-size:22px;text-align:left;margin:0 0 10px;color:black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n  \u003cdiv style=\"border-top:1px solid #d9d9d9;border-bottom:1px solid #d9d9d9;\"\u003e\n    \u003cdiv style=\"padding:12px 0;border-bottom:1px solid #e5e5e5;\"\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0 0 4px;color:black;\"\u003e\u003cstrong\u003eHow should the analyzer be prepared before a measurement?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0;color:black;\"\u003ePlace it on a firm, level bench, install a clean and dry sample pan, allow at least 30 minutes of powered warm-up, and check or calibrate the weighing system as needed.\u003c\/p\u003e\n\u003c\/div\u003e\n    \u003cdiv style=\"padding:12px 0;border-bottom:1px solid #e5e5e5;\"\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0 0 4px;color:black;\"\u003e\u003cstrong\u003eWhich heating mode should be selected?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0;color:black;\"\u003eUse standard heating for routine samples, gentle heating for heat-sensitive materials, rapid heating for suitable high-moisture samples, and step heating when the validated method requires staged drying.\u003c\/p\u003e\n\u003c\/div\u003e\n    \u003cdiv style=\"padding:12px 0;border-bottom:1px solid #e5e5e5;\"\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0 0 4px;color:black;\"\u003e\u003cstrong\u003eWhy can results vary between repeated tests?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0;color:black;\"\u003eDifferences in sample uniformity, sample amount, preparation, starting chamber conditions, temperature, heating program, or endpoint can change the result. Keep these conditions consistent when comparing tests.\u003c\/p\u003e\n\u003c\/div\u003e\n    \u003cdiv style=\"padding:12px 0;border-bottom:1px solid #e5e5e5;\"\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0 0 4px;color:black;\"\u003e\u003cstrong\u003eDoes the displayed moisture result measure water only?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0;color:black;\"\u003eNot necessarily. The result is based on mass lost during heating and may include volatile substances other than water. Validate the method against an appropriate reference method when water-specific results are required.\u003c\/p\u003e\n\u003c\/div\u003e\n    \u003cdiv style=\"padding:12px 0;\"\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0 0 4px;color:black;\"\u003e\u003cstrong\u003eHow should the analyzer be cleaned?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0;color:black;\"\u003eSwitch off, unplug, and allow the instrument to cool completely. Clean removable parts and exterior surfaces with a soft, lightly dampened lint-free cloth. Do not immerse the instrument, spray liquid onto it, or use abrasive cleaners or organic solvents.\u003c\/p\u003e\n\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cp style=\"font-size:22px;text-align:left;margin:24px 0 10px;color:#9b1c1c;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n  \u003cdiv style=\"box-sizing:border-box;border-left:5px solid #d97706;background-color:#fff7e6;padding:14px 16px;color:black;\"\u003e\n    \u003cul style=\"font-size:16px;line-height:24px;margin:0;padding-left:22px;\"\u003e\n      \u003cli style=\"margin-bottom:8px;\"\u003eUse only the specified 110 V AC, 60 Hz supply and a grounded US power cord. Do not operate the analyzer with damaged wiring or allow liquid to enter the housing or connectors.\u003c\/li\u003e\n      \u003cli style=\"margin-bottom:8px;\"\u003eThe heater, chamber, sample pan, and sample can remain hot after testing. Keep ventilation openings clear, maintain at least 1 m (39.4 in) of overhead clearance, and use suitable tools and heat protection.\u003c\/li\u003e\n      \u003cli style=\"margin-bottom:8px;\"\u003eDo not test explosive materials or samples that may react dangerously. Flammable, solvent-containing, toxic, or corrosive samples require a documented safety assessment and suitable extraction before testing.\u003c\/li\u003e\n      \u003cli style=\"margin-bottom:8px;\"\u003eDo not exceed the instrument capacity. Taring does not increase capacity, and a 100 g calibration weight must never be placed on a 62 g model.\u003c\/li\u003e\n      \u003cli\u003eSwitch off, unplug, and allow the analyzer to cool before cleaning, moving, or connecting accessories. Do not open the housing or attempt internal repairs.\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/body\u003e","brand":"U.S. Solid","offers":[{"title":"Default Title","offer_id":49230406680831,"sku":"JFVM00002-62G","price":1556.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/1_3c576104-d0c1-4342-8cd4-27960ff14140.png?v=1789626584"},{"product_id":"halogen-moisture-analyzer-40-230-c-drying-range-124-g-capacity-0-002-g-0-01-readability-5-in-touchscreen-rs232-moisture-balance","title":"Halogen Moisture Analyzer, 40-230 °C Drying Range, 124 g Capacity, 0.002 g\/0.01% Readability, 5-in Touchscreen, RS232 Moisture Balance","description":"\u003cbody\u003e\n\u003cstyle\u003e@media only screen and (max-width:600px){.desktop-only{display:none!important}.mobile-only{display:block!important}}@media only screen and (min-width:601px){.mobile-only{display:none!important}}\u003c\/style\u003e\n\u003cdiv class=\"desktop-only\"\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFVM\/coverimage.png\" alt=\"Halogen moisture analyzer cover image\" style=\"display:block;width:100%;height:auto;border:0;\"\u003e\u003cp style=\"font-size:22px;font-family:Arial;text-align:left;margin-top:0;margin-bottom:10px;color:black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:26px;margin:10px 0 0;color:black;font-family:Arial;\"\u003eThe U.S. Solid USS-VM00003-124G halogen moisture analyzer provides a 40 to 230 deg C drying range for loss-on-drying methods, including procedures with setpoints above 200 deg C. It combines sample heating and weighing to calculate moisture and solids content for food powders, grain, feed, plastic pellets and other suitable laboratory materials.\u003cbr\u003e\u003cbr\u003eReview initial and final sample weights, dry basis and wet basis ratios, temperature and elapsed time. User permissions and custom sample identifiers help organize shared testing workflows. Select the temperature and endpoint for the material; mass loss can include volatile substances other than water, and readability describes display increments rather than measurement accuracy.\u003c\/p\u003e\n\u003cdiv style=\"flex:1;padding:0;font-family:Arial;\"\u003e\n\u003cp style=\"font-size:22px;text-align:left;margin-top:20px;margin-bottom:10px;color:black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFVM\/features.png\" alt=\"Halogen moisture analyzer features\" style=\"display:block;width:100%;height:auto;border:0;\"\u003e\u003cp style=\"font-size:22px;text-align:left;margin-top:20px;margin-bottom:10px;color:black;\"\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFVM\/applications.png\" alt=\"Halogen moisture analyzer applications\" style=\"display:block;width:100%;height:auto;border:0;\"\u003e\u003cp style=\"font-size:22px;text-align:left;margin-top:20px;margin-bottom:10px;color:black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"width:100%;overflow-x:auto;\"\u003e\u003ctable style=\"border-collapse:collapse;border:0;width:100%;font-family:Arial;overflow-x:auto;background-color:#FFFFFF;\"\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003eUSS-VM00003-124G\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eCapacity\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e124 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eWeighing Readability\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e0.002 g\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eMoisture Readability\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e0.01%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eWeighing Repeatability\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003eStandard deviation ≤3d (d=0.002 g)\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eWeighing Sensor\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003eHBM strain gauge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eNet Weight\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e5.8 kg\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eHeating Source\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e350 W halogen lamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eTemperature Setting Range\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e40–230 °C (104–446 °F)\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eTemperature Resolution \/ Setting Step\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e0.1 °C \/ 0.1 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eTemperature Sensor \/ Control\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003ePT-1000 \/ PID\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003ePower Supply\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e110 V AC, 60 Hz, grounded US plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eMaximum Instrument Input\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e500 W\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eDisplay\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e5 in color touchscreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eHeating Programs\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003eStandard, gentle, rapid, step\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eStop Modes\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003eAutomatic, timed, manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eTimed Mode Duration\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e1–99 min; 1 second setting increments\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eMethod Storage\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e96 custom methods\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eResult Storage\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003eUp to 2004 completed records\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eUSB Record Backup\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003eUp to 2000 records per HTML export\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eSample Pan Diameter\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e90 mm\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eHeating Chamber Height\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e24.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eInterfaces\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003eRS-232; USB record backup\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eOperating Temperature\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e1–38 °C; ideally 18–25 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eDimensions\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e23.4 × 35 × 20.5 cm\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eCommon Series Features\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003eLive drying curve; user permissions; custom sample identification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cdiv data-section=\"faq-warning\" style=\"width:100%;box-sizing:border-box;font-family:Arial;margin-top:24px;\"\u003e\n  \u003cp style=\"font-size:22px;text-align:left;margin:0 0 10px;color:black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n  \u003cdiv style=\"border-top:1px solid #d9d9d9;border-bottom:1px solid #d9d9d9;\"\u003e\n    \u003cdiv style=\"padding:12px 0;border-bottom:1px solid #e5e5e5;\"\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0 0 4px;color:black;\"\u003e\u003cstrong\u003eHow should the analyzer be prepared before a measurement?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0;color:black;\"\u003ePlace it on a firm, level bench, install a clean and dry sample pan, allow at least 30 minutes of powered warm-up, and check or calibrate the weighing system as needed.\u003c\/p\u003e\n\u003c\/div\u003e\n    \u003cdiv style=\"padding:12px 0;border-bottom:1px solid #e5e5e5;\"\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0 0 4px;color:black;\"\u003e\u003cstrong\u003eWhich heating mode should be selected?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0;color:black;\"\u003eUse standard heating for routine samples, gentle heating for heat-sensitive materials, rapid heating for suitable high-moisture samples, and step heating when the validated method requires staged drying.\u003c\/p\u003e\n\u003c\/div\u003e\n    \u003cdiv style=\"padding:12px 0;border-bottom:1px solid #e5e5e5;\"\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0 0 4px;color:black;\"\u003e\u003cstrong\u003eWhy can results vary between repeated tests?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0;color:black;\"\u003eDifferences in sample uniformity, sample amount, preparation, starting chamber conditions, temperature, heating program, or endpoint can change the result. Keep these conditions consistent when comparing tests.\u003c\/p\u003e\n\u003c\/div\u003e\n    \u003cdiv style=\"padding:12px 0;border-bottom:1px solid #e5e5e5;\"\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0 0 4px;color:black;\"\u003e\u003cstrong\u003eDoes the displayed moisture result measure water only?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0;color:black;\"\u003eNot necessarily. The result is based on mass lost during heating and may include volatile substances other than water. Validate the method against an appropriate reference method when water-specific results are required.\u003c\/p\u003e\n\u003c\/div\u003e\n    \u003cdiv style=\"padding:12px 0;\"\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0 0 4px;color:black;\"\u003e\u003cstrong\u003eHow should the analyzer be cleaned?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0;color:black;\"\u003eSwitch off, unplug, and allow the instrument to cool completely. Clean removable parts and exterior surfaces with a soft, lightly dampened lint-free cloth. Do not immerse the instrument, spray liquid onto it, or use abrasive cleaners or organic solvents.\u003c\/p\u003e\n\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cp style=\"font-size:22px;text-align:left;margin:24px 0 10px;color:#9b1c1c;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n  \u003cdiv style=\"box-sizing:border-box;border-left:5px solid #d97706;background-color:#fff7e6;padding:14px 16px;color:black;\"\u003e\n    \u003cul style=\"font-size:16px;line-height:24px;margin:0;padding-left:22px;\"\u003e\n      \u003cli style=\"margin-bottom:8px;\"\u003eUse only the specified 110 V AC, 60 Hz supply and a grounded US power cord. Do not operate the analyzer with damaged wiring or allow liquid to enter the housing or connectors.\u003c\/li\u003e\n      \u003cli style=\"margin-bottom:8px;\"\u003eThe heater, chamber, sample pan, and sample can remain hot after testing. Keep ventilation openings clear, maintain at least 1 m (39.4 in) of overhead clearance, and use suitable tools and heat protection.\u003c\/li\u003e\n      \u003cli style=\"margin-bottom:8px;\"\u003eDo not test explosive materials or samples that may react dangerously. Flammable, solvent-containing, toxic, or corrosive samples require a documented safety assessment and suitable extraction before testing.\u003c\/li\u003e\n      \u003cli style=\"margin-bottom:8px;\"\u003eDo not exceed the instrument capacity. Taring does not increase capacity, and a 100 g calibration weight must never be placed on a 62 g model.\u003c\/li\u003e\n      \u003cli\u003eSwitch off, unplug, and allow the analyzer to cool before cleaning, moving, or connecting accessories. Do not open the housing or attempt internal repairs.\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mobile-only\"\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFVM\/coverimage.png\" alt=\"Halogen moisture analyzer cover image\" style=\"display:block;width:100%;height:auto;border:0;\"\u003e\u003cp style=\"font-size:22px;text-align:left;margin-top:0;margin-bottom:10px;color:black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:26px;margin:0;color:black;font-family:Arial;\"\u003eThe U.S. Solid USS-VM00003-124G halogen moisture analyzer provides a 40 to 230 deg C drying range for loss-on-drying methods, including procedures with setpoints above 200 deg C. It combines sample heating and weighing to calculate moisture and solids content for food powders, grain, feed, plastic pellets and other suitable laboratory materials.\u003cbr\u003e\u003cbr\u003eReview initial and final sample weights, dry basis and wet basis ratios, temperature and elapsed time. User permissions and custom sample identifiers help organize shared testing workflows. Select the temperature and endpoint for the material; mass loss can include volatile substances other than water, and readability describes display increments rather than measurement accuracy.\u003c\/p\u003e\n\u003cdiv style=\"flex:1;padding:0;font-family:Arial;\"\u003e\n\u003cp style=\"font-size:22px;text-align:left;margin-top:20px;margin-bottom:10px;color:black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFVM\/features.png\" alt=\"Halogen moisture analyzer features\" style=\"display:block;width:100%;height:auto;border:0;\"\u003e\u003cp style=\"font-size:22px;text-align:left;margin-top:20px;margin-bottom:10px;color:black;\"\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFVM\/applications.png\" alt=\"Halogen moisture analyzer applications\" style=\"display:block;width:100%;height:auto;border:0;\"\u003e\u003cp style=\"font-size:22px;text-align:left;margin-top:20px;margin-bottom:10px;color:black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"width:100%;overflow-x:auto;\"\u003e\u003ctable style=\"border-collapse:collapse;border:0;width:100%;font-family:Arial;overflow-x:auto;background-color:#FFFFFF;\"\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003eUSS-VM00003-124G\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eCapacity\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e124 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eWeighing Readability\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e0.002 g\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eMoisture Readability\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e0.01%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eWeighing Repeatability\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003eStandard deviation ≤3d (d=0.002 g)\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eWeighing Sensor\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003eHBM strain gauge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eNet Weight\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e5.8 kg\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eHeating Source\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e350 W halogen lamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eTemperature Setting Range\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e40–230 °C (104–446 °F)\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eTemperature Resolution \/ Setting Step\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e0.1 °C \/ 0.1 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eTemperature Sensor \/ Control\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003ePT-1000 \/ PID\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003ePower Supply\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e110 V AC, 60 Hz, grounded US plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eMaximum Instrument Input\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e500 W\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eDisplay\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e5 in color touchscreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eHeating Programs\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003eStandard, gentle, rapid, step\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eStop Modes\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003eAutomatic, timed, manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eTimed Mode Duration\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e1–99 min; 1 second setting increments\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eMethod Storage\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e96 custom methods\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eResult Storage\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003eUp to 2004 completed records\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eUSB Record Backup\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003eUp to 2000 records per HTML export\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eSample Pan Diameter\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e90 mm\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eHeating Chamber Height\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e24.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eInterfaces\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003eRS-232; USB record backup\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eOperating Temperature\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e1–38 °C; ideally 18–25 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eDimensions\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e23.4 × 35 × 20.5 cm\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eCommon Series Features\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003eLive drying curve; user permissions; custom sample identification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cdiv data-section=\"faq-warning\" style=\"width:100%;box-sizing:border-box;font-family:Arial;margin-top:24px;\"\u003e\n  \u003cp style=\"font-size:22px;text-align:left;margin:0 0 10px;color:black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n  \u003cdiv style=\"border-top:1px solid #d9d9d9;border-bottom:1px solid #d9d9d9;\"\u003e\n    \u003cdiv style=\"padding:12px 0;border-bottom:1px solid #e5e5e5;\"\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0 0 4px;color:black;\"\u003e\u003cstrong\u003eHow should the analyzer be prepared before a measurement?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0;color:black;\"\u003ePlace it on a firm, level bench, install a clean and dry sample pan, allow at least 30 minutes of powered warm-up, and check or calibrate the weighing system as needed.\u003c\/p\u003e\n\u003c\/div\u003e\n    \u003cdiv style=\"padding:12px 0;border-bottom:1px solid #e5e5e5;\"\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0 0 4px;color:black;\"\u003e\u003cstrong\u003eWhich heating mode should be selected?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0;color:black;\"\u003eUse standard heating for routine samples, gentle heating for heat-sensitive materials, rapid heating for suitable high-moisture samples, and step heating when the validated method requires staged drying.\u003c\/p\u003e\n\u003c\/div\u003e\n    \u003cdiv style=\"padding:12px 0;border-bottom:1px solid #e5e5e5;\"\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0 0 4px;color:black;\"\u003e\u003cstrong\u003eWhy can results vary between repeated tests?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0;color:black;\"\u003eDifferences in sample uniformity, sample amount, preparation, starting chamber conditions, temperature, heating program, or endpoint can change the result. Keep these conditions consistent when comparing tests.\u003c\/p\u003e\n\u003c\/div\u003e\n    \u003cdiv style=\"padding:12px 0;border-bottom:1px solid #e5e5e5;\"\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0 0 4px;color:black;\"\u003e\u003cstrong\u003eDoes the displayed moisture result measure water only?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0;color:black;\"\u003eNot necessarily. The result is based on mass lost during heating and may include volatile substances other than water. Validate the method against an appropriate reference method when water-specific results are required.\u003c\/p\u003e\n\u003c\/div\u003e\n    \u003cdiv style=\"padding:12px 0;\"\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0 0 4px;color:black;\"\u003e\u003cstrong\u003eHow should the analyzer be cleaned?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0;color:black;\"\u003eSwitch off, unplug, and allow the instrument to cool completely. Clean removable parts and exterior surfaces with a soft, lightly dampened lint-free cloth. Do not immerse the instrument, spray liquid onto it, or use abrasive cleaners or organic solvents.\u003c\/p\u003e\n\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cp style=\"font-size:22px;text-align:left;margin:24px 0 10px;color:#9b1c1c;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n  \u003cdiv style=\"box-sizing:border-box;border-left:5px solid #d97706;background-color:#fff7e6;padding:14px 16px;color:black;\"\u003e\n    \u003cul style=\"font-size:16px;line-height:24px;margin:0;padding-left:22px;\"\u003e\n      \u003cli style=\"margin-bottom:8px;\"\u003eUse only the specified 110 V AC, 60 Hz supply and a grounded US power cord. Do not operate the analyzer with damaged wiring or allow liquid to enter the housing or connectors.\u003c\/li\u003e\n      \u003cli style=\"margin-bottom:8px;\"\u003eThe heater, chamber, sample pan, and sample can remain hot after testing. Keep ventilation openings clear, maintain at least 1 m (39.4 in) of overhead clearance, and use suitable tools and heat protection.\u003c\/li\u003e\n      \u003cli style=\"margin-bottom:8px;\"\u003eDo not test explosive materials or samples that may react dangerously. Flammable, solvent-containing, toxic, or corrosive samples require a documented safety assessment and suitable extraction before testing.\u003c\/li\u003e\n      \u003cli style=\"margin-bottom:8px;\"\u003eDo not exceed the instrument capacity. Taring does not increase capacity, and a 100 g calibration weight must never be placed on a 62 g model.\u003c\/li\u003e\n      \u003cli\u003eSwitch off, unplug, and allow the analyzer to cool before cleaning, moving, or connecting accessories. Do not open the housing or attempt internal repairs.\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/body\u003e","brand":"U.S. Solid","offers":[{"title":"Default Title","offer_id":49230410776831,"sku":"JFVM00003-124G","price":2203.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/1_905b3b9b-4f05-4639-aa06-53bc833568ea.png?v=1789626646"},{"product_id":"halogen-moisture-analyzer-40-230-c-drying-range-62-g-capacity-0-002-g-0-01-readability-5-in-touchscreen-rs232-moisture-balance","title":"Halogen Moisture Analyzer, 40-230 °C Drying Range, 62 g Capacity, 0.002 g\/0.01% Readability, 5-in Touchscreen, RS232 Moisture Balance","description":"\u003cbody\u003e\n\u003cstyle\u003e@media only screen and (max-width:600px){.desktop-only{display:none!important}.mobile-only{display:block!important}}@media only screen and (min-width:601px){.mobile-only{display:none!important}}\u003c\/style\u003e\n\u003cdiv class=\"desktop-only\"\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFVM\/coverimage.png\" alt=\"Halogen moisture analyzer cover image\" style=\"display:block;width:100%;height:auto;border:0;\"\u003e\u003cp style=\"font-size:22px;font-family:Arial;text-align:left;margin-top:0;margin-bottom:10px;color:black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:26px;margin:10px 0 0;color:black;font-family:Arial;\"\u003eThe U.S. Solid USS-VM00003-62G halogen moisture analyzer provides a 40 to 230 deg C drying range for loss-on-drying methods, including procedures with setpoints above 200 deg C. It combines sample heating and weighing to calculate moisture and solids content for food powders, grain, feed, plastic pellets and other suitable laboratory materials.\u003cbr\u003e\u003cbr\u003eReview initial and final sample weights, dry basis and wet basis ratios, temperature and elapsed time. User permissions and custom sample identifiers help organize shared testing workflows. Select the temperature and endpoint for the material; mass loss can include volatile substances other than water, and readability describes display increments rather than measurement accuracy.\u003c\/p\u003e\n\u003cdiv style=\"flex:1;padding:0;font-family:Arial;\"\u003e\n\u003cp style=\"font-size:22px;text-align:left;margin-top:20px;margin-bottom:10px;color:black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFVM\/features.png\" alt=\"Halogen moisture analyzer features\" style=\"display:block;width:100%;height:auto;border:0;\"\u003e\u003cp style=\"font-size:22px;text-align:left;margin-top:20px;margin-bottom:10px;color:black;\"\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFVM\/applications.png\" alt=\"Halogen moisture analyzer applications\" style=\"display:block;width:100%;height:auto;border:0;\"\u003e\u003cp style=\"font-size:22px;text-align:left;margin-top:20px;margin-bottom:10px;color:black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"width:100%;overflow-x:auto;\"\u003e\u003ctable style=\"border-collapse:collapse;border:0;width:100%;font-family:Arial;overflow-x:auto;background-color:#FFFFFF;\"\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003eUSS-VM00003-62G\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eCapacity\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e62 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eWeighing Readability\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e0.002 g\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eMoisture Readability\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e0.01%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eWeighing Repeatability\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003eStandard deviation ≤3d (d=0.002 g)\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eWeighing Sensor\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003eHBM strain gauge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eNet Weight\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e5.8 kg\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eHeating Source\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e350 W halogen lamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eTemperature Setting Range\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e40–230 °C (104–446 °F)\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eTemperature Resolution \/ Setting Step\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e0.1 °C \/ 0.1 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eTemperature Sensor \/ Control\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003ePT-1000 \/ PID\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003ePower Supply\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e110 V AC, 60 Hz, grounded US plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eMaximum Instrument Input\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e500 W\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eDisplay\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e5 in color touchscreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eHeating Programs\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003eStandard, gentle, rapid, step\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eStop Modes\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003eAutomatic, timed, manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eTimed Mode Duration\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e1–99 min; 1 second setting increments\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eMethod Storage\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e96 custom methods\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eResult Storage\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003eUp to 2004 completed records\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eUSB Record Backup\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003eUp to 2000 records per HTML export\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eSample Pan Diameter\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e90 mm\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eHeating Chamber Height\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e24.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eInterfaces\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003eRS-232; USB record backup\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eOperating Temperature\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e1–38 °C; ideally 18–25 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eDimensions\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e23.4 × 35 × 20.5 cm\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eCommon Series Features\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003eLive drying curve; user permissions; custom sample identification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cdiv data-section=\"faq-warning\" style=\"width:100%;box-sizing:border-box;font-family:Arial;margin-top:24px;\"\u003e\n  \u003cp style=\"font-size:22px;text-align:left;margin:0 0 10px;color:black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n  \u003cdiv style=\"border-top:1px solid #d9d9d9;border-bottom:1px solid #d9d9d9;\"\u003e\n    \u003cdiv style=\"padding:12px 0;border-bottom:1px solid #e5e5e5;\"\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0 0 4px;color:black;\"\u003e\u003cstrong\u003eHow should the analyzer be prepared before a measurement?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0;color:black;\"\u003ePlace it on a firm, level bench, install a clean and dry sample pan, allow at least 30 minutes of powered warm-up, and check or calibrate the weighing system as needed.\u003c\/p\u003e\n\u003c\/div\u003e\n    \u003cdiv style=\"padding:12px 0;border-bottom:1px solid #e5e5e5;\"\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0 0 4px;color:black;\"\u003e\u003cstrong\u003eWhich heating mode should be selected?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0;color:black;\"\u003eUse standard heating for routine samples, gentle heating for heat-sensitive materials, rapid heating for suitable high-moisture samples, and step heating when the validated method requires staged drying.\u003c\/p\u003e\n\u003c\/div\u003e\n    \u003cdiv style=\"padding:12px 0;border-bottom:1px solid #e5e5e5;\"\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0 0 4px;color:black;\"\u003e\u003cstrong\u003eWhy can results vary between repeated tests?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0;color:black;\"\u003eDifferences in sample uniformity, sample amount, preparation, starting chamber conditions, temperature, heating program, or endpoint can change the result. Keep these conditions consistent when comparing tests.\u003c\/p\u003e\n\u003c\/div\u003e\n    \u003cdiv style=\"padding:12px 0;border-bottom:1px solid #e5e5e5;\"\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0 0 4px;color:black;\"\u003e\u003cstrong\u003eDoes the displayed moisture result measure water only?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0;color:black;\"\u003eNot necessarily. The result is based on mass lost during heating and may include volatile substances other than water. Validate the method against an appropriate reference method when water-specific results are required.\u003c\/p\u003e\n\u003c\/div\u003e\n    \u003cdiv style=\"padding:12px 0;\"\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0 0 4px;color:black;\"\u003e\u003cstrong\u003eHow should the analyzer be cleaned?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0;color:black;\"\u003eSwitch off, unplug, and allow the instrument to cool completely. Clean removable parts and exterior surfaces with a soft, lightly dampened lint-free cloth. Do not immerse the instrument, spray liquid onto it, or use abrasive cleaners or organic solvents.\u003c\/p\u003e\n\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cp style=\"font-size:22px;text-align:left;margin:24px 0 10px;color:#9b1c1c;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n  \u003cdiv style=\"box-sizing:border-box;border-left:5px solid #d97706;background-color:#fff7e6;padding:14px 16px;color:black;\"\u003e\n    \u003cul style=\"font-size:16px;line-height:24px;margin:0;padding-left:22px;\"\u003e\n      \u003cli style=\"margin-bottom:8px;\"\u003eUse only the specified 110 V AC, 60 Hz supply and a grounded US power cord. Do not operate the analyzer with damaged wiring or allow liquid to enter the housing or connectors.\u003c\/li\u003e\n      \u003cli style=\"margin-bottom:8px;\"\u003eThe heater, chamber, sample pan, and sample can remain hot after testing. Keep ventilation openings clear, maintain at least 1 m (39.4 in) of overhead clearance, and use suitable tools and heat protection.\u003c\/li\u003e\n      \u003cli style=\"margin-bottom:8px;\"\u003eDo not test explosive materials or samples that may react dangerously. Flammable, solvent-containing, toxic, or corrosive samples require a documented safety assessment and suitable extraction before testing.\u003c\/li\u003e\n      \u003cli style=\"margin-bottom:8px;\"\u003eDo not exceed the instrument capacity. Taring does not increase capacity, and a 100 g calibration weight must never be placed on a 62 g model.\u003c\/li\u003e\n      \u003cli\u003eSwitch off, unplug, and allow the analyzer to cool before cleaning, moving, or connecting accessories. Do not open the housing or attempt internal repairs.\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mobile-only\"\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFVM\/coverimage.png\" alt=\"Halogen moisture analyzer cover image\" style=\"display:block;width:100%;height:auto;border:0;\"\u003e\u003cp style=\"font-size:22px;text-align:left;margin-top:0;margin-bottom:10px;color:black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:26px;margin:0;color:black;font-family:Arial;\"\u003eThe U.S. Solid USS-VM00003-62G halogen moisture analyzer provides a 40 to 230 deg C drying range for loss-on-drying methods, including procedures with setpoints above 200 deg C. It combines sample heating and weighing to calculate moisture and solids content for food powders, grain, feed, plastic pellets and other suitable laboratory materials.\u003cbr\u003e\u003cbr\u003eReview initial and final sample weights, dry basis and wet basis ratios, temperature and elapsed time. User permissions and custom sample identifiers help organize shared testing workflows. Select the temperature and endpoint for the material; mass loss can include volatile substances other than water, and readability describes display increments rather than measurement accuracy.\u003c\/p\u003e\n\u003cdiv style=\"flex:1;padding:0;font-family:Arial;\"\u003e\n\u003cp style=\"font-size:22px;text-align:left;margin-top:20px;margin-bottom:10px;color:black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFVM\/features.png\" alt=\"Halogen moisture analyzer features\" style=\"display:block;width:100%;height:auto;border:0;\"\u003e\u003cp style=\"font-size:22px;text-align:left;margin-top:20px;margin-bottom:10px;color:black;\"\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFVM\/applications.png\" alt=\"Halogen moisture analyzer applications\" style=\"display:block;width:100%;height:auto;border:0;\"\u003e\u003cp style=\"font-size:22px;text-align:left;margin-top:20px;margin-bottom:10px;color:black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"width:100%;overflow-x:auto;\"\u003e\u003ctable style=\"border-collapse:collapse;border:0;width:100%;font-family:Arial;overflow-x:auto;background-color:#FFFFFF;\"\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003eUSS-VM00003-62G\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eCapacity\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e62 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eWeighing Readability\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e0.002 g\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eMoisture Readability\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e0.01%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eWeighing Repeatability\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003eStandard deviation ≤3d (d=0.002 g)\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eWeighing Sensor\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003eHBM strain gauge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eNet Weight\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e5.8 kg\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eHeating Source\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e350 W halogen lamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eTemperature Setting Range\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e40–230 °C (104–446 °F)\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eTemperature Resolution \/ Setting Step\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e0.1 °C \/ 0.1 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eTemperature Sensor \/ Control\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003ePT-1000 \/ PID\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003ePower Supply\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e110 V AC, 60 Hz, grounded US plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eMaximum Instrument Input\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e500 W\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eDisplay\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e5 in color touchscreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eHeating Programs\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003eStandard, gentle, rapid, step\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eStop Modes\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003eAutomatic, timed, manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eTimed Mode Duration\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e1–99 min; 1 second setting increments\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eMethod Storage\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e96 custom methods\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eResult Storage\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003eUp to 2004 completed records\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eUSB Record Backup\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003eUp to 2000 records per HTML export\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eSample Pan Diameter\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e90 mm\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eHeating Chamber Height\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e24.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eInterfaces\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003eRS-232; USB record backup\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eOperating Temperature\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e1–38 °C; ideally 18–25 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eDimensions\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e23.4 × 35 × 20.5 cm\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eCommon Series Features\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003eLive drying curve; user permissions; custom sample identification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cdiv data-section=\"faq-warning\" style=\"width:100%;box-sizing:border-box;font-family:Arial;margin-top:24px;\"\u003e\n  \u003cp style=\"font-size:22px;text-align:left;margin:0 0 10px;color:black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n  \u003cdiv style=\"border-top:1px solid #d9d9d9;border-bottom:1px solid #d9d9d9;\"\u003e\n    \u003cdiv style=\"padding:12px 0;border-bottom:1px solid #e5e5e5;\"\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0 0 4px;color:black;\"\u003e\u003cstrong\u003eHow should the analyzer be prepared before a measurement?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0;color:black;\"\u003ePlace it on a firm, level bench, install a clean and dry sample pan, allow at least 30 minutes of powered warm-up, and check or calibrate the weighing system as needed.\u003c\/p\u003e\n\u003c\/div\u003e\n    \u003cdiv style=\"padding:12px 0;border-bottom:1px solid #e5e5e5;\"\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0 0 4px;color:black;\"\u003e\u003cstrong\u003eWhich heating mode should be selected?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0;color:black;\"\u003eUse standard heating for routine samples, gentle heating for heat-sensitive materials, rapid heating for suitable high-moisture samples, and step heating when the validated method requires staged drying.\u003c\/p\u003e\n\u003c\/div\u003e\n    \u003cdiv style=\"padding:12px 0;border-bottom:1px solid #e5e5e5;\"\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0 0 4px;color:black;\"\u003e\u003cstrong\u003eWhy can results vary between repeated tests?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0;color:black;\"\u003eDifferences in sample uniformity, sample amount, preparation, starting chamber conditions, temperature, heating program, or endpoint can change the result. Keep these conditions consistent when comparing tests.\u003c\/p\u003e\n\u003c\/div\u003e\n    \u003cdiv style=\"padding:12px 0;border-bottom:1px solid #e5e5e5;\"\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0 0 4px;color:black;\"\u003e\u003cstrong\u003eDoes the displayed moisture result measure water only?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0;color:black;\"\u003eNot necessarily. The result is based on mass lost during heating and may include volatile substances other than water. Validate the method against an appropriate reference method when water-specific results are required.\u003c\/p\u003e\n\u003c\/div\u003e\n    \u003cdiv style=\"padding:12px 0;\"\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0 0 4px;color:black;\"\u003e\u003cstrong\u003eHow should the analyzer be cleaned?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0;color:black;\"\u003eSwitch off, unplug, and allow the instrument to cool completely. Clean removable parts and exterior surfaces with a soft, lightly dampened lint-free cloth. Do not immerse the instrument, spray liquid onto it, or use abrasive cleaners or organic solvents.\u003c\/p\u003e\n\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cp style=\"font-size:22px;text-align:left;margin:24px 0 10px;color:#9b1c1c;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n  \u003cdiv style=\"box-sizing:border-box;border-left:5px solid #d97706;background-color:#fff7e6;padding:14px 16px;color:black;\"\u003e\n    \u003cul style=\"font-size:16px;line-height:24px;margin:0;padding-left:22px;\"\u003e\n      \u003cli style=\"margin-bottom:8px;\"\u003eUse only the specified 110 V AC, 60 Hz supply and a grounded US power cord. Do not operate the analyzer with damaged wiring or allow liquid to enter the housing or connectors.\u003c\/li\u003e\n      \u003cli style=\"margin-bottom:8px;\"\u003eThe heater, chamber, sample pan, and sample can remain hot after testing. Keep ventilation openings clear, maintain at least 1 m (39.4 in) of overhead clearance, and use suitable tools and heat protection.\u003c\/li\u003e\n      \u003cli style=\"margin-bottom:8px;\"\u003eDo not test explosive materials or samples that may react dangerously. Flammable, solvent-containing, toxic, or corrosive samples require a documented safety assessment and suitable extraction before testing.\u003c\/li\u003e\n      \u003cli style=\"margin-bottom:8px;\"\u003eDo not exceed the instrument capacity. Taring does not increase capacity, and a 100 g calibration weight must never be placed on a 62 g model.\u003c\/li\u003e\n      \u003cli\u003eSwitch off, unplug, and allow the analyzer to cool before cleaning, moving, or connecting accessories. Do not open the housing or attempt internal repairs.\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/body\u003e","brand":"U.S. Solid","offers":[{"title":"Default Title","offer_id":49230412611839,"sku":"JFVM00003-62G","price":2122.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/1_571fe657-5b9b-4a8b-91b4-e4948f366c2d.png?v=1789626647"},{"product_id":"halogen-moisture-analyzer-40-230-c-drying-range-124-g-capacity-0-001-g-0-01-readability-5-in-touchscreen-rs232-moisture-balance","title":"Halogen Moisture Analyzer, 40-230 °C Drying Range, 124 g Capacity, 0.001 g\/0.01% Readability, 5-in Touchscreen, RS232 Moisture Balance","description":"\u003cbody\u003e\n\u003cstyle\u003e@media only screen and (max-width:600px){.desktop-only{display:none!important}.mobile-only{display:block!important}}@media only screen and (min-width:601px){.mobile-only{display:none!important}}\u003c\/style\u003e\n\u003cdiv class=\"desktop-only\"\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFVM\/coverimage.png\" alt=\"Halogen moisture analyzer cover image\" style=\"display:block;width:100%;height:auto;border:0;\"\u003e\u003cp style=\"font-size:22px;font-family:Arial;text-align:left;margin-top:0;margin-bottom:10px;color:black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:26px;margin:10px 0 0;color:black;font-family:Arial;\"\u003eThe U.S. Solid USS-VM00004-124G halogen moisture analyzer provides a 40 to 230 deg C drying range for loss-on-drying methods, including procedures with setpoints above 200 deg C. It combines sample heating and weighing to calculate moisture and solids content for food powders, grain, feed, plastic pellets and other suitable laboratory materials.\u003cbr\u003e\u003cbr\u003eReview initial and final sample weights, dry basis and wet basis ratios, temperature and elapsed time. User permissions and custom sample identifiers help organize shared testing workflows. Select the temperature and endpoint for the material; mass loss can include volatile substances other than water, and readability describes display increments rather than measurement accuracy.\u003c\/p\u003e\n\u003cdiv style=\"flex:1;padding:0;font-family:Arial;\"\u003e\n\u003cp style=\"font-size:22px;text-align:left;margin-top:20px;margin-bottom:10px;color:black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFVM\/features.png\" alt=\"Halogen moisture analyzer features\" style=\"display:block;width:100%;height:auto;border:0;\"\u003e\u003cp style=\"font-size:22px;text-align:left;margin-top:20px;margin-bottom:10px;color:black;\"\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFVM\/applications.png\" alt=\"Halogen moisture analyzer applications\" style=\"display:block;width:100%;height:auto;border:0;\"\u003e\u003cp style=\"font-size:22px;text-align:left;margin-top:20px;margin-bottom:10px;color:black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"width:100%;overflow-x:auto;\"\u003e\u003ctable style=\"border-collapse:collapse;border:0;width:100%;font-family:Arial;overflow-x:auto;background-color:#FFFFFF;\"\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003eUSS-VM00004-124G\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eCapacity\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e124 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eWeighing Readability\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e0.001 g\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eMoisture Readability\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e0.01%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eWeighing Repeatability\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003eStandard deviation ≤3d (d=0.001 g)\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eWeighing Sensor\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003eElectromagnetic force\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eNet Weight\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e8.8 kg\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eHeating Source\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e350 W halogen lamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eTemperature Setting Range\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e40–230 °C (104–446 °F)\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eTemperature Resolution \/ Setting Step\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e0.1 °C \/ 0.1 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eTemperature Sensor \/ Control\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003ePT-1000 \/ PID\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003ePower Supply\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e110 V AC, 60 Hz, grounded US plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eMaximum Instrument Input\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e500 W\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eDisplay\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e5 in color touchscreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eHeating Programs\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003eStandard, gentle, rapid, step\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eStop Modes\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003eAutomatic, timed, manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eTimed Mode Duration\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e1–99 min; 1 second setting increments\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eMethod Storage\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e96 custom methods\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eResult Storage\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003eUp to 2004 completed records\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eUSB Record Backup\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003eUp to 2000 records per HTML export\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eSample Pan Diameter\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e90 mm\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eHeating Chamber Height\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e24.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eInterfaces\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003eRS-232; USB record backup\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eOperating Temperature\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e1–38 °C; ideally 18–25 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eDimensions\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e23.4 × 35 × 20.5 cm\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eCommon Series Features\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003eLive drying curve; user permissions; custom sample identification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cdiv data-section=\"faq-warning\" style=\"width:100%;box-sizing:border-box;font-family:Arial;margin-top:24px;\"\u003e\n  \u003cp style=\"font-size:22px;text-align:left;margin:0 0 10px;color:black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n  \u003cdiv style=\"border-top:1px solid #d9d9d9;border-bottom:1px solid #d9d9d9;\"\u003e\n    \u003cdiv style=\"padding:12px 0;border-bottom:1px solid #e5e5e5;\"\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0 0 4px;color:black;\"\u003e\u003cstrong\u003eHow should the analyzer be prepared before a measurement?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0;color:black;\"\u003ePlace it on a firm, level bench, install a clean and dry sample pan, allow at least 30 minutes of powered warm-up, and check or calibrate the weighing system as needed.\u003c\/p\u003e\n\u003c\/div\u003e\n    \u003cdiv style=\"padding:12px 0;border-bottom:1px solid #e5e5e5;\"\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0 0 4px;color:black;\"\u003e\u003cstrong\u003eWhich heating mode should be selected?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0;color:black;\"\u003eUse standard heating for routine samples, gentle heating for heat-sensitive materials, rapid heating for suitable high-moisture samples, and step heating when the validated method requires staged drying.\u003c\/p\u003e\n\u003c\/div\u003e\n    \u003cdiv style=\"padding:12px 0;border-bottom:1px solid #e5e5e5;\"\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0 0 4px;color:black;\"\u003e\u003cstrong\u003eWhy can results vary between repeated tests?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0;color:black;\"\u003eDifferences in sample uniformity, sample amount, preparation, starting chamber conditions, temperature, heating program, or endpoint can change the result. Keep these conditions consistent when comparing tests.\u003c\/p\u003e\n\u003c\/div\u003e\n    \u003cdiv style=\"padding:12px 0;border-bottom:1px solid #e5e5e5;\"\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0 0 4px;color:black;\"\u003e\u003cstrong\u003eDoes the displayed moisture result measure water only?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0;color:black;\"\u003eNot necessarily. The result is based on mass lost during heating and may include volatile substances other than water. Validate the method against an appropriate reference method when water-specific results are required.\u003c\/p\u003e\n\u003c\/div\u003e\n    \u003cdiv style=\"padding:12px 0;\"\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0 0 4px;color:black;\"\u003e\u003cstrong\u003eHow should the analyzer be cleaned?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0;color:black;\"\u003eSwitch off, unplug, and allow the instrument to cool completely. Clean removable parts and exterior surfaces with a soft, lightly dampened lint-free cloth. Do not immerse the instrument, spray liquid onto it, or use abrasive cleaners or organic solvents.\u003c\/p\u003e\n\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cp style=\"font-size:22px;text-align:left;margin:24px 0 10px;color:#9b1c1c;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n  \u003cdiv style=\"box-sizing:border-box;border-left:5px solid #d97706;background-color:#fff7e6;padding:14px 16px;color:black;\"\u003e\n    \u003cul style=\"font-size:16px;line-height:24px;margin:0;padding-left:22px;\"\u003e\n      \u003cli style=\"margin-bottom:8px;\"\u003eUse only the specified 110 V AC, 60 Hz supply and a grounded US power cord. Do not operate the analyzer with damaged wiring or allow liquid to enter the housing or connectors.\u003c\/li\u003e\n      \u003cli style=\"margin-bottom:8px;\"\u003eThe heater, chamber, sample pan, and sample can remain hot after testing. Keep ventilation openings clear, maintain at least 1 m (39.4 in) of overhead clearance, and use suitable tools and heat protection.\u003c\/li\u003e\n      \u003cli style=\"margin-bottom:8px;\"\u003eDo not test explosive materials or samples that may react dangerously. Flammable, solvent-containing, toxic, or corrosive samples require a documented safety assessment and suitable extraction before testing.\u003c\/li\u003e\n      \u003cli style=\"margin-bottom:8px;\"\u003eDo not exceed the instrument capacity. Taring does not increase capacity, and a 100 g calibration weight must never be placed on a 62 g model.\u003c\/li\u003e\n      \u003cli\u003eSwitch off, unplug, and allow the analyzer to cool before cleaning, moving, or connecting accessories. Do not open the housing or attempt internal repairs.\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mobile-only\"\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFVM\/coverimage.png\" alt=\"Halogen moisture analyzer cover image\" style=\"display:block;width:100%;height:auto;border:0;\"\u003e\u003cp style=\"font-size:22px;text-align:left;margin-top:0;margin-bottom:10px;color:black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:26px;margin:0;color:black;font-family:Arial;\"\u003eThe U.S. Solid USS-VM00004-124G halogen moisture analyzer provides a 40 to 230 deg C drying range for loss-on-drying methods, including procedures with setpoints above 200 deg C. It combines sample heating and weighing to calculate moisture and solids content for food powders, grain, feed, plastic pellets and other suitable laboratory materials.\u003cbr\u003e\u003cbr\u003eReview initial and final sample weights, dry basis and wet basis ratios, temperature and elapsed time. User permissions and custom sample identifiers help organize shared testing workflows. Select the temperature and endpoint for the material; mass loss can include volatile substances other than water, and readability describes display increments rather than measurement accuracy.\u003c\/p\u003e\n\u003cdiv style=\"flex:1;padding:0;font-family:Arial;\"\u003e\n\u003cp style=\"font-size:22px;text-align:left;margin-top:20px;margin-bottom:10px;color:black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFVM\/features.png\" alt=\"Halogen moisture analyzer features\" style=\"display:block;width:100%;height:auto;border:0;\"\u003e\u003cp style=\"font-size:22px;text-align:left;margin-top:20px;margin-bottom:10px;color:black;\"\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFVM\/applications.png\" alt=\"Halogen moisture analyzer applications\" style=\"display:block;width:100%;height:auto;border:0;\"\u003e\u003cp style=\"font-size:22px;text-align:left;margin-top:20px;margin-bottom:10px;color:black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"width:100%;overflow-x:auto;\"\u003e\u003ctable style=\"border-collapse:collapse;border:0;width:100%;font-family:Arial;overflow-x:auto;background-color:#FFFFFF;\"\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003eUSS-VM00004-124G\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eCapacity\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e124 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eWeighing Readability\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e0.001 g\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eMoisture Readability\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e0.01%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eWeighing Repeatability\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003eStandard deviation ≤3d (d=0.001 g)\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eWeighing Sensor\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003eElectromagnetic force\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eNet Weight\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e8.8 kg\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eHeating Source\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e350 W halogen lamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eTemperature Setting Range\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e40–230 °C (104–446 °F)\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eTemperature Resolution \/ Setting Step\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e0.1 °C \/ 0.1 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eTemperature Sensor \/ Control\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003ePT-1000 \/ PID\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003ePower Supply\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e110 V AC, 60 Hz, grounded US plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eMaximum Instrument Input\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e500 W\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eDisplay\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e5 in color touchscreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eHeating Programs\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003eStandard, gentle, rapid, step\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eStop Modes\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003eAutomatic, timed, manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eTimed Mode Duration\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e1–99 min; 1 second setting increments\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eMethod Storage\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e96 custom methods\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eResult Storage\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003eUp to 2004 completed records\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eUSB Record Backup\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003eUp to 2000 records per HTML export\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eSample Pan Diameter\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e90 mm\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eHeating Chamber Height\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e24.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eInterfaces\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003eRS-232; USB record backup\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eOperating Temperature\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e1–38 °C; ideally 18–25 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eDimensions\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e23.4 × 35 × 20.5 cm\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eCommon Series Features\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003eLive drying curve; user permissions; custom sample identification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cdiv data-section=\"faq-warning\" style=\"width:100%;box-sizing:border-box;font-family:Arial;margin-top:24px;\"\u003e\n  \u003cp style=\"font-size:22px;text-align:left;margin:0 0 10px;color:black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n  \u003cdiv style=\"border-top:1px solid #d9d9d9;border-bottom:1px solid #d9d9d9;\"\u003e\n    \u003cdiv style=\"padding:12px 0;border-bottom:1px solid #e5e5e5;\"\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0 0 4px;color:black;\"\u003e\u003cstrong\u003eHow should the analyzer be prepared before a measurement?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0;color:black;\"\u003ePlace it on a firm, level bench, install a clean and dry sample pan, allow at least 30 minutes of powered warm-up, and check or calibrate the weighing system as needed.\u003c\/p\u003e\n\u003c\/div\u003e\n    \u003cdiv style=\"padding:12px 0;border-bottom:1px solid #e5e5e5;\"\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0 0 4px;color:black;\"\u003e\u003cstrong\u003eWhich heating mode should be selected?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0;color:black;\"\u003eUse standard heating for routine samples, gentle heating for heat-sensitive materials, rapid heating for suitable high-moisture samples, and step heating when the validated method requires staged drying.\u003c\/p\u003e\n\u003c\/div\u003e\n    \u003cdiv style=\"padding:12px 0;border-bottom:1px solid #e5e5e5;\"\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0 0 4px;color:black;\"\u003e\u003cstrong\u003eWhy can results vary between repeated tests?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0;color:black;\"\u003eDifferences in sample uniformity, sample amount, preparation, starting chamber conditions, temperature, heating program, or endpoint can change the result. Keep these conditions consistent when comparing tests.\u003c\/p\u003e\n\u003c\/div\u003e\n    \u003cdiv style=\"padding:12px 0;border-bottom:1px solid #e5e5e5;\"\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0 0 4px;color:black;\"\u003e\u003cstrong\u003eDoes the displayed moisture result measure water only?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0;color:black;\"\u003eNot necessarily. The result is based on mass lost during heating and may include volatile substances other than water. Validate the method against an appropriate reference method when water-specific results are required.\u003c\/p\u003e\n\u003c\/div\u003e\n    \u003cdiv style=\"padding:12px 0;\"\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0 0 4px;color:black;\"\u003e\u003cstrong\u003eHow should the analyzer be cleaned?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0;color:black;\"\u003eSwitch off, unplug, and allow the instrument to cool completely. Clean removable parts and exterior surfaces with a soft, lightly dampened lint-free cloth. Do not immerse the instrument, spray liquid onto it, or use abrasive cleaners or organic solvents.\u003c\/p\u003e\n\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cp style=\"font-size:22px;text-align:left;margin:24px 0 10px;color:#9b1c1c;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n  \u003cdiv style=\"box-sizing:border-box;border-left:5px solid #d97706;background-color:#fff7e6;padding:14px 16px;color:black;\"\u003e\n    \u003cul style=\"font-size:16px;line-height:24px;margin:0;padding-left:22px;\"\u003e\n      \u003cli style=\"margin-bottom:8px;\"\u003eUse only the specified 110 V AC, 60 Hz supply and a grounded US power cord. Do not operate the analyzer with damaged wiring or allow liquid to enter the housing or connectors.\u003c\/li\u003e\n      \u003cli style=\"margin-bottom:8px;\"\u003eThe heater, chamber, sample pan, and sample can remain hot after testing. Keep ventilation openings clear, maintain at least 1 m (39.4 in) of overhead clearance, and use suitable tools and heat protection.\u003c\/li\u003e\n      \u003cli style=\"margin-bottom:8px;\"\u003eDo not test explosive materials or samples that may react dangerously. Flammable, solvent-containing, toxic, or corrosive samples require a documented safety assessment and suitable extraction before testing.\u003c\/li\u003e\n      \u003cli style=\"margin-bottom:8px;\"\u003eDo not exceed the instrument capacity. Taring does not increase capacity, and a 100 g calibration weight must never be placed on a 62 g model.\u003c\/li\u003e\n      \u003cli\u003eSwitch off, unplug, and allow the analyzer to cool before cleaning, moving, or connecting accessories. Do not open the housing or attempt internal repairs.\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/body\u003e","brand":"U.S. Solid","offers":[{"title":"Default Title","offer_id":49230414643455,"sku":"JFVM00004-124G","price":2688.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/1_135daedd-60b4-4bd7-942c-4c1edde6f53b.png?v=1789626650"},{"product_id":"halogen-moisture-analyzer-40-230-c-drying-range-62-g-capacity-0-001-g-0-01-readability-5-in-touchscreen-rs232-moisture-balance","title":"Halogen Moisture Analyzer, 40-230 °C Drying Range, 62 g Capacity, 0.001 g\/0.01% Readability, 5-in Touchscreen, RS232 Moisture Balance","description":"\u003cbody\u003e\n\u003cstyle\u003e@media only screen and (max-width:600px){.desktop-only{display:none!important}.mobile-only{display:block!important}}@media only screen and (min-width:601px){.mobile-only{display:none!important}}\u003c\/style\u003e\n\u003cdiv class=\"desktop-only\"\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFVM\/coverimage.png\" alt=\"Halogen moisture analyzer cover image\" style=\"display:block;width:100%;height:auto;border:0;\"\u003e\u003cp style=\"font-size:22px;font-family:Arial;text-align:left;margin-top:0;margin-bottom:10px;color:black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:26px;margin:10px 0 0;color:black;font-family:Arial;\"\u003eThe U.S. Solid USS-VM00004-62G halogen moisture analyzer provides a 40 to 230 deg C drying range for loss-on-drying methods, including procedures with setpoints above 200 deg C. It combines sample heating and weighing to calculate moisture and solids content for food powders, grain, feed, plastic pellets and other suitable laboratory materials.\u003cbr\u003e\u003cbr\u003eReview initial and final sample weights, dry basis and wet basis ratios, temperature and elapsed time. User permissions and custom sample identifiers help organize shared testing workflows. Select the temperature and endpoint for the material; mass loss can include volatile substances other than water, and readability describes display increments rather than measurement accuracy.\u003c\/p\u003e\n\u003cdiv style=\"flex:1;padding:0;font-family:Arial;\"\u003e\n\u003cp style=\"font-size:22px;text-align:left;margin-top:20px;margin-bottom:10px;color:black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFVM\/features.png\" alt=\"Halogen moisture analyzer features\" style=\"display:block;width:100%;height:auto;border:0;\"\u003e\u003cp style=\"font-size:22px;text-align:left;margin-top:20px;margin-bottom:10px;color:black;\"\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFVM\/applications.png\" alt=\"Halogen moisture analyzer applications\" style=\"display:block;width:100%;height:auto;border:0;\"\u003e\u003cp style=\"font-size:22px;text-align:left;margin-top:20px;margin-bottom:10px;color:black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"width:100%;overflow-x:auto;\"\u003e\u003ctable style=\"border-collapse:collapse;border:0;width:100%;font-family:Arial;overflow-x:auto;background-color:#FFFFFF;\"\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003eUSS-VM00004-62G\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eCapacity\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e62 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eWeighing Readability\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e0.001 g\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eMoisture Readability\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e0.01%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eWeighing Repeatability\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003eStandard deviation ≤3d (d=0.001 g)\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eWeighing Sensor\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003eElectromagnetic force\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eNet Weight\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e8.8 kg\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eHeating Source\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e350 W halogen lamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eTemperature Setting Range\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e40–230 °C (104–446 °F)\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eTemperature Resolution \/ Setting Step\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e0.1 °C \/ 0.1 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eTemperature Sensor \/ Control\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003ePT-1000 \/ PID\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003ePower Supply\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e110 V AC, 60 Hz, grounded US plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eMaximum Instrument Input\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e500 W\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eDisplay\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e5 in color touchscreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eHeating Programs\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003eStandard, gentle, rapid, step\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eStop Modes\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003eAutomatic, timed, manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eTimed Mode Duration\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e1–99 min; 1 second setting increments\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eMethod Storage\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e96 custom methods\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eResult Storage\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003eUp to 2004 completed records\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eUSB Record Backup\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003eUp to 2000 records per HTML export\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eSample Pan Diameter\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e90 mm\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eHeating Chamber Height\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e24.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eInterfaces\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003eRS-232; USB record backup\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eOperating Temperature\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e1–38 °C; ideally 18–25 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eDimensions\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e23.4 × 35 × 20.5 cm\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eCommon Series Features\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003eLive drying curve; user permissions; custom sample identification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cdiv data-section=\"faq-warning\" style=\"width:100%;box-sizing:border-box;font-family:Arial;margin-top:24px;\"\u003e\n  \u003cp style=\"font-size:22px;text-align:left;margin:0 0 10px;color:black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n  \u003cdiv style=\"border-top:1px solid #d9d9d9;border-bottom:1px solid #d9d9d9;\"\u003e\n    \u003cdiv style=\"padding:12px 0;border-bottom:1px solid #e5e5e5;\"\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0 0 4px;color:black;\"\u003e\u003cstrong\u003eHow should the analyzer be prepared before a measurement?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0;color:black;\"\u003ePlace it on a firm, level bench, install a clean and dry sample pan, allow at least 30 minutes of powered warm-up, and check or calibrate the weighing system as needed.\u003c\/p\u003e\n\u003c\/div\u003e\n    \u003cdiv style=\"padding:12px 0;border-bottom:1px solid #e5e5e5;\"\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0 0 4px;color:black;\"\u003e\u003cstrong\u003eWhich heating mode should be selected?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0;color:black;\"\u003eUse standard heating for routine samples, gentle heating for heat-sensitive materials, rapid heating for suitable high-moisture samples, and step heating when the validated method requires staged drying.\u003c\/p\u003e\n\u003c\/div\u003e\n    \u003cdiv style=\"padding:12px 0;border-bottom:1px solid #e5e5e5;\"\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0 0 4px;color:black;\"\u003e\u003cstrong\u003eWhy can results vary between repeated tests?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0;color:black;\"\u003eDifferences in sample uniformity, sample amount, preparation, starting chamber conditions, temperature, heating program, or endpoint can change the result. Keep these conditions consistent when comparing tests.\u003c\/p\u003e\n\u003c\/div\u003e\n    \u003cdiv style=\"padding:12px 0;border-bottom:1px solid #e5e5e5;\"\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0 0 4px;color:black;\"\u003e\u003cstrong\u003eDoes the displayed moisture result measure water only?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0;color:black;\"\u003eNot necessarily. The result is based on mass lost during heating and may include volatile substances other than water. Validate the method against an appropriate reference method when water-specific results are required.\u003c\/p\u003e\n\u003c\/div\u003e\n    \u003cdiv style=\"padding:12px 0;\"\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0 0 4px;color:black;\"\u003e\u003cstrong\u003eHow should the analyzer be cleaned?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0;color:black;\"\u003eSwitch off, unplug, and allow the instrument to cool completely. Clean removable parts and exterior surfaces with a soft, lightly dampened lint-free cloth. Do not immerse the instrument, spray liquid onto it, or use abrasive cleaners or organic solvents.\u003c\/p\u003e\n\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cp style=\"font-size:22px;text-align:left;margin:24px 0 10px;color:#9b1c1c;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n  \u003cdiv style=\"box-sizing:border-box;border-left:5px solid #d97706;background-color:#fff7e6;padding:14px 16px;color:black;\"\u003e\n    \u003cul style=\"font-size:16px;line-height:24px;margin:0;padding-left:22px;\"\u003e\n      \u003cli style=\"margin-bottom:8px;\"\u003eUse only the specified 110 V AC, 60 Hz supply and a grounded US power cord. Do not operate the analyzer with damaged wiring or allow liquid to enter the housing or connectors.\u003c\/li\u003e\n      \u003cli style=\"margin-bottom:8px;\"\u003eThe heater, chamber, sample pan, and sample can remain hot after testing. Keep ventilation openings clear, maintain at least 1 m (39.4 in) of overhead clearance, and use suitable tools and heat protection.\u003c\/li\u003e\n      \u003cli style=\"margin-bottom:8px;\"\u003eDo not test explosive materials or samples that may react dangerously. Flammable, solvent-containing, toxic, or corrosive samples require a documented safety assessment and suitable extraction before testing.\u003c\/li\u003e\n      \u003cli style=\"margin-bottom:8px;\"\u003eDo not exceed the instrument capacity. Taring does not increase capacity, and a 100 g calibration weight must never be placed on a 62 g model.\u003c\/li\u003e\n      \u003cli\u003eSwitch off, unplug, and allow the analyzer to cool before cleaning, moving, or connecting accessories. Do not open the housing or attempt internal repairs.\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mobile-only\"\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFVM\/coverimage.png\" alt=\"Halogen moisture analyzer cover image\" style=\"display:block;width:100%;height:auto;border:0;\"\u003e\u003cp style=\"font-size:22px;text-align:left;margin-top:0;margin-bottom:10px;color:black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:26px;margin:0;color:black;font-family:Arial;\"\u003eThe U.S. Solid USS-VM00004-62G halogen moisture analyzer provides a 40 to 230 deg C drying range for loss-on-drying methods, including procedures with setpoints above 200 deg C. It combines sample heating and weighing to calculate moisture and solids content for food powders, grain, feed, plastic pellets and other suitable laboratory materials.\u003cbr\u003e\u003cbr\u003eReview initial and final sample weights, dry basis and wet basis ratios, temperature and elapsed time. User permissions and custom sample identifiers help organize shared testing workflows. Select the temperature and endpoint for the material; mass loss can include volatile substances other than water, and readability describes display increments rather than measurement accuracy.\u003c\/p\u003e\n\u003cdiv style=\"flex:1;padding:0;font-family:Arial;\"\u003e\n\u003cp style=\"font-size:22px;text-align:left;margin-top:20px;margin-bottom:10px;color:black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFVM\/features.png\" alt=\"Halogen moisture analyzer features\" style=\"display:block;width:100%;height:auto;border:0;\"\u003e\u003cp style=\"font-size:22px;text-align:left;margin-top:20px;margin-bottom:10px;color:black;\"\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFVM\/applications.png\" alt=\"Halogen moisture analyzer applications\" style=\"display:block;width:100%;height:auto;border:0;\"\u003e\u003cp style=\"font-size:22px;text-align:left;margin-top:20px;margin-bottom:10px;color:black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"width:100%;overflow-x:auto;\"\u003e\u003ctable style=\"border-collapse:collapse;border:0;width:100%;font-family:Arial;overflow-x:auto;background-color:#FFFFFF;\"\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003eUSS-VM00004-62G\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eCapacity\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e62 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eWeighing Readability\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e0.001 g\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eMoisture Readability\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e0.01%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eWeighing Repeatability\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003eStandard deviation ≤3d (d=0.001 g)\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eWeighing Sensor\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003eElectromagnetic force\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eNet Weight\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e8.8 kg\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eHeating Source\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e350 W halogen lamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eTemperature Setting Range\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e40–230 °C (104–446 °F)\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eTemperature Resolution \/ Setting Step\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e0.1 °C \/ 0.1 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eTemperature Sensor \/ Control\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003ePT-1000 \/ PID\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003ePower Supply\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e110 V AC, 60 Hz, grounded US plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eMaximum Instrument Input\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e500 W\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eDisplay\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e5 in color touchscreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eHeating Programs\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003eStandard, gentle, rapid, step\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eStop Modes\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003eAutomatic, timed, manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eTimed Mode Duration\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e1–99 min; 1 second setting increments\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eMethod Storage\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e96 custom methods\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eResult Storage\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003eUp to 2004 completed records\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eUSB Record Backup\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003eUp to 2000 records per HTML export\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eSample Pan Diameter\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e90 mm\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eHeating Chamber Height\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e24.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eInterfaces\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003eRS-232; USB record backup\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eOperating Temperature\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e1–38 °C; ideally 18–25 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eDimensions\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e23.4 × 35 × 20.5 cm\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eCommon Series Features\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003eLive drying curve; user permissions; custom sample identification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cdiv data-section=\"faq-warning\" style=\"width:100%;box-sizing:border-box;font-family:Arial;margin-top:24px;\"\u003e\n  \u003cp style=\"font-size:22px;text-align:left;margin:0 0 10px;color:black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n  \u003cdiv style=\"border-top:1px solid #d9d9d9;border-bottom:1px solid #d9d9d9;\"\u003e\n    \u003cdiv style=\"padding:12px 0;border-bottom:1px solid #e5e5e5;\"\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0 0 4px;color:black;\"\u003e\u003cstrong\u003eHow should the analyzer be prepared before a measurement?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0;color:black;\"\u003ePlace it on a firm, level bench, install a clean and dry sample pan, allow at least 30 minutes of powered warm-up, and check or calibrate the weighing system as needed.\u003c\/p\u003e\n\u003c\/div\u003e\n    \u003cdiv style=\"padding:12px 0;border-bottom:1px solid #e5e5e5;\"\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0 0 4px;color:black;\"\u003e\u003cstrong\u003eWhich heating mode should be selected?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0;color:black;\"\u003eUse standard heating for routine samples, gentle heating for heat-sensitive materials, rapid heating for suitable high-moisture samples, and step heating when the validated method requires staged drying.\u003c\/p\u003e\n\u003c\/div\u003e\n    \u003cdiv style=\"padding:12px 0;border-bottom:1px solid #e5e5e5;\"\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0 0 4px;color:black;\"\u003e\u003cstrong\u003eWhy can results vary between repeated tests?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0;color:black;\"\u003eDifferences in sample uniformity, sample amount, preparation, starting chamber conditions, temperature, heating program, or endpoint can change the result. Keep these conditions consistent when comparing tests.\u003c\/p\u003e\n\u003c\/div\u003e\n    \u003cdiv style=\"padding:12px 0;border-bottom:1px solid #e5e5e5;\"\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0 0 4px;color:black;\"\u003e\u003cstrong\u003eDoes the displayed moisture result measure water only?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0;color:black;\"\u003eNot necessarily. The result is based on mass lost during heating and may include volatile substances other than water. Validate the method against an appropriate reference method when water-specific results are required.\u003c\/p\u003e\n\u003c\/div\u003e\n    \u003cdiv style=\"padding:12px 0;\"\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0 0 4px;color:black;\"\u003e\u003cstrong\u003eHow should the analyzer be cleaned?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0;color:black;\"\u003eSwitch off, unplug, and allow the instrument to cool completely. Clean removable parts and exterior surfaces with a soft, lightly dampened lint-free cloth. Do not immerse the instrument, spray liquid onto it, or use abrasive cleaners or organic solvents.\u003c\/p\u003e\n\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cp style=\"font-size:22px;text-align:left;margin:24px 0 10px;color:#9b1c1c;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n  \u003cdiv style=\"box-sizing:border-box;border-left:5px solid #d97706;background-color:#fff7e6;padding:14px 16px;color:black;\"\u003e\n    \u003cul style=\"font-size:16px;line-height:24px;margin:0;padding-left:22px;\"\u003e\n      \u003cli style=\"margin-bottom:8px;\"\u003eUse only the specified 110 V AC, 60 Hz supply and a grounded US power cord. Do not operate the analyzer with damaged wiring or allow liquid to enter the housing or connectors.\u003c\/li\u003e\n      \u003cli style=\"margin-bottom:8px;\"\u003eThe heater, chamber, sample pan, and sample can remain hot after testing. Keep ventilation openings clear, maintain at least 1 m (39.4 in) of overhead clearance, and use suitable tools and heat protection.\u003c\/li\u003e\n      \u003cli style=\"margin-bottom:8px;\"\u003eDo not test explosive materials or samples that may react dangerously. Flammable, solvent-containing, toxic, or corrosive samples require a documented safety assessment and suitable extraction before testing.\u003c\/li\u003e\n      \u003cli style=\"margin-bottom:8px;\"\u003eDo not exceed the instrument capacity. Taring does not increase capacity, and a 100 g calibration weight must never be placed on a 62 g model.\u003c\/li\u003e\n      \u003cli\u003eSwitch off, unplug, and allow the analyzer to cool before cleaning, moving, or connecting accessories. Do not open the housing or attempt internal repairs.\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/body\u003e","brand":"U.S. Solid","offers":[{"title":"Default Title","offer_id":49230417887487,"sku":"JFVM00004-62G","price":2559.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/1_5cb990b7-897e-4bc5-afaf-fbe1a1c5469d.png?v=1789626656"},{"product_id":"halogen-moisture-analyzer-40-230-c-drying-range-124-g-capacity-0-0001-g-0-001-readability-5-in-touchscreen-rs232-moisture-balance","title":"Halogen Moisture Analyzer, 40-230 °C Drying Range, 124 g Capacity, 0.0001 g\/0.001% Readability, 5-in Touchscreen, RS232 Moisture Balance","description":"\u003cbody\u003e\n\u003cstyle\u003e@media only screen and (max-width:600px){.desktop-only{display:none!important}.mobile-only{display:block!important}}@media only screen and (min-width:601px){.mobile-only{display:none!important}}\u003c\/style\u003e\n\u003cdiv class=\"desktop-only\"\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFVM\/coverimage.png\" alt=\"Halogen moisture analyzer cover image\" style=\"display:block;width:100%;height:auto;border:0;\"\u003e\u003cp style=\"font-size:22px;font-family:Arial;text-align:left;margin-top:0;margin-bottom:10px;color:black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:26px;margin:10px 0 0;color:black;font-family:Arial;\"\u003eThe U.S. Solid USS-VM00005-124G halogen moisture analyzer provides a 40 to 230 deg C drying range for loss-on-drying methods, including procedures with setpoints above 200 deg C. It combines sample heating and weighing to calculate moisture and solids content for food powders, grain, feed, plastic pellets and other suitable laboratory materials.\u003cbr\u003e\u003cbr\u003eReview initial and final sample weights, dry basis and wet basis ratios, temperature and elapsed time. User permissions and custom sample identifiers help organize shared testing workflows. Select the temperature and endpoint for the material; mass loss can include volatile substances other than water, and readability describes display increments rather than measurement accuracy.\u003c\/p\u003e\n\u003cdiv style=\"flex:1;padding:0;font-family:Arial;\"\u003e\n\u003cp style=\"font-size:22px;text-align:left;margin-top:20px;margin-bottom:10px;color:black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFVM\/features.png\" alt=\"Halogen moisture analyzer features\" style=\"display:block;width:100%;height:auto;border:0;\"\u003e\u003cp style=\"font-size:22px;text-align:left;margin-top:20px;margin-bottom:10px;color:black;\"\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFVM\/applications.png\" alt=\"Halogen moisture analyzer applications\" style=\"display:block;width:100%;height:auto;border:0;\"\u003e\u003cp style=\"font-size:22px;text-align:left;margin-top:20px;margin-bottom:10px;color:black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"width:100%;overflow-x:auto;\"\u003e\u003ctable style=\"border-collapse:collapse;border:0;width:100%;font-family:Arial;overflow-x:auto;background-color:#FFFFFF;\"\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003eUSS-VM00005-124G\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eCapacity\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e124 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eWeighing Readability\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e0.0001 g\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eMoisture Readability\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e0.001%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eWeighing Repeatability\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003eStandard deviation ≤3d (d=0.0001 g)\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eWeighing Sensor\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003eElectromagnetic force\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eNet Weight\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e8.8 kg\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eHeating Source\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e350 W halogen lamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eTemperature Setting Range\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e40–230 °C (104–446 °F)\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eTemperature Resolution \/ Setting Step\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e0.1 °C \/ 0.1 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eTemperature Sensor \/ Control\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003ePT-1000 \/ PID\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003ePower Supply\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e110 V AC, 60 Hz, grounded US plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eMaximum Instrument Input\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e500 W\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eDisplay\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e5 in color touchscreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eHeating Programs\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003eStandard, gentle, rapid, step\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eStop Modes\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003eAutomatic, timed, manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eTimed Mode Duration\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e1–99 min; 1 second setting increments\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eMethod Storage\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e96 custom methods\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eResult Storage\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003eUp to 2004 completed records\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eUSB Record Backup\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003eUp to 2000 records per HTML export\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eSample Pan Diameter\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e90 mm\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eHeating Chamber Height\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e24.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eInterfaces\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003eRS-232; USB record backup\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eOperating Temperature\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e1–38 °C; ideally 18–25 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eDimensions\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e23.4 × 35 × 20.5 cm\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eCommon Series Features\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003eLive drying curve; user permissions; custom sample identification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cdiv data-section=\"faq-warning\" style=\"width:100%;box-sizing:border-box;font-family:Arial;margin-top:24px;\"\u003e\n  \u003cp style=\"font-size:22px;text-align:left;margin:0 0 10px;color:black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n  \u003cdiv style=\"border-top:1px solid #d9d9d9;border-bottom:1px solid #d9d9d9;\"\u003e\n    \u003cdiv style=\"padding:12px 0;border-bottom:1px solid #e5e5e5;\"\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0 0 4px;color:black;\"\u003e\u003cstrong\u003eHow should the analyzer be prepared before a measurement?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0;color:black;\"\u003ePlace it on a firm, level bench, install a clean and dry sample pan, allow at least 30 minutes of powered warm-up, and check or calibrate the weighing system as needed.\u003c\/p\u003e\n\u003c\/div\u003e\n    \u003cdiv style=\"padding:12px 0;border-bottom:1px solid #e5e5e5;\"\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0 0 4px;color:black;\"\u003e\u003cstrong\u003eWhich heating mode should be selected?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0;color:black;\"\u003eUse standard heating for routine samples, gentle heating for heat-sensitive materials, rapid heating for suitable high-moisture samples, and step heating when the validated method requires staged drying.\u003c\/p\u003e\n\u003c\/div\u003e\n    \u003cdiv style=\"padding:12px 0;border-bottom:1px solid #e5e5e5;\"\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0 0 4px;color:black;\"\u003e\u003cstrong\u003eWhy can results vary between repeated tests?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0;color:black;\"\u003eDifferences in sample uniformity, sample amount, preparation, starting chamber conditions, temperature, heating program, or endpoint can change the result. Keep these conditions consistent when comparing tests.\u003c\/p\u003e\n\u003c\/div\u003e\n    \u003cdiv style=\"padding:12px 0;border-bottom:1px solid #e5e5e5;\"\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0 0 4px;color:black;\"\u003e\u003cstrong\u003eDoes the displayed moisture result measure water only?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0;color:black;\"\u003eNot necessarily. The result is based on mass lost during heating and may include volatile substances other than water. Validate the method against an appropriate reference method when water-specific results are required.\u003c\/p\u003e\n\u003c\/div\u003e\n    \u003cdiv style=\"padding:12px 0;\"\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0 0 4px;color:black;\"\u003e\u003cstrong\u003eHow should the analyzer be cleaned?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0;color:black;\"\u003eSwitch off, unplug, and allow the instrument to cool completely. Clean removable parts and exterior surfaces with a soft, lightly dampened lint-free cloth. Do not immerse the instrument, spray liquid onto it, or use abrasive cleaners or organic solvents.\u003c\/p\u003e\n\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cp style=\"font-size:22px;text-align:left;margin:24px 0 10px;color:#9b1c1c;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n  \u003cdiv style=\"box-sizing:border-box;border-left:5px solid #d97706;background-color:#fff7e6;padding:14px 16px;color:black;\"\u003e\n    \u003cul style=\"font-size:16px;line-height:24px;margin:0;padding-left:22px;\"\u003e\n      \u003cli style=\"margin-bottom:8px;\"\u003eUse only the specified 110 V AC, 60 Hz supply and a grounded US power cord. Do not operate the analyzer with damaged wiring or allow liquid to enter the housing or connectors.\u003c\/li\u003e\n      \u003cli style=\"margin-bottom:8px;\"\u003eThe heater, chamber, sample pan, and sample can remain hot after testing. Keep ventilation openings clear, maintain at least 1 m (39.4 in) of overhead clearance, and use suitable tools and heat protection.\u003c\/li\u003e\n      \u003cli style=\"margin-bottom:8px;\"\u003eDo not test explosive materials or samples that may react dangerously. Flammable, solvent-containing, toxic, or corrosive samples require a documented safety assessment and suitable extraction before testing.\u003c\/li\u003e\n      \u003cli style=\"margin-bottom:8px;\"\u003eDo not exceed the instrument capacity. Taring does not increase capacity, and a 100 g calibration weight must never be placed on a 62 g model.\u003c\/li\u003e\n      \u003cli\u003eSwitch off, unplug, and allow the analyzer to cool before cleaning, moving, or connecting accessories. Do not open the housing or attempt internal repairs.\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mobile-only\"\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFVM\/coverimage.png\" alt=\"Halogen moisture analyzer cover image\" style=\"display:block;width:100%;height:auto;border:0;\"\u003e\u003cp style=\"font-size:22px;text-align:left;margin-top:0;margin-bottom:10px;color:black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:26px;margin:0;color:black;font-family:Arial;\"\u003eThe U.S. Solid USS-VM00005-124G halogen moisture analyzer provides a 40 to 230 deg C drying range for loss-on-drying methods, including procedures with setpoints above 200 deg C. It combines sample heating and weighing to calculate moisture and solids content for food powders, grain, feed, plastic pellets and other suitable laboratory materials.\u003cbr\u003e\u003cbr\u003eReview initial and final sample weights, dry basis and wet basis ratios, temperature and elapsed time. User permissions and custom sample identifiers help organize shared testing workflows. Select the temperature and endpoint for the material; mass loss can include volatile substances other than water, and readability describes display increments rather than measurement accuracy.\u003c\/p\u003e\n\u003cdiv style=\"flex:1;padding:0;font-family:Arial;\"\u003e\n\u003cp style=\"font-size:22px;text-align:left;margin-top:20px;margin-bottom:10px;color:black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFVM\/features.png\" alt=\"Halogen moisture analyzer features\" style=\"display:block;width:100%;height:auto;border:0;\"\u003e\u003cp style=\"font-size:22px;text-align:left;margin-top:20px;margin-bottom:10px;color:black;\"\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFVM\/applications.png\" alt=\"Halogen moisture analyzer applications\" style=\"display:block;width:100%;height:auto;border:0;\"\u003e\u003cp style=\"font-size:22px;text-align:left;margin-top:20px;margin-bottom:10px;color:black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"width:100%;overflow-x:auto;\"\u003e\u003ctable style=\"border-collapse:collapse;border:0;width:100%;font-family:Arial;overflow-x:auto;background-color:#FFFFFF;\"\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003eUSS-VM00005-124G\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eCapacity\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e124 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eWeighing Readability\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e0.0001 g\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eMoisture Readability\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e0.001%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eWeighing Repeatability\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003eStandard deviation ≤3d (d=0.0001 g)\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eWeighing Sensor\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003eElectromagnetic force\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eNet Weight\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e8.8 kg\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eHeating Source\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e350 W halogen lamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eTemperature Setting Range\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e40–230 °C (104–446 °F)\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eTemperature Resolution \/ Setting Step\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e0.1 °C \/ 0.1 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eTemperature Sensor \/ Control\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003ePT-1000 \/ PID\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003ePower Supply\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e110 V AC, 60 Hz, grounded US plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eMaximum Instrument Input\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e500 W\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eDisplay\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e5 in color touchscreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eHeating Programs\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003eStandard, gentle, rapid, step\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eStop Modes\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003eAutomatic, timed, manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eTimed Mode Duration\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e1–99 min; 1 second setting increments\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eMethod Storage\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e96 custom methods\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eResult Storage\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003eUp to 2004 completed records\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eUSB Record Backup\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003eUp to 2000 records per HTML export\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eSample Pan Diameter\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e90 mm\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eHeating Chamber Height\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e24.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eInterfaces\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003eRS-232; USB record backup\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eOperating Temperature\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e1–38 °C; ideally 18–25 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eDimensions\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e23.4 × 35 × 20.5 cm\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eCommon Series Features\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003eLive drying curve; user permissions; custom sample identification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cdiv data-section=\"faq-warning\" style=\"width:100%;box-sizing:border-box;font-family:Arial;margin-top:24px;\"\u003e\n  \u003cp style=\"font-size:22px;text-align:left;margin:0 0 10px;color:black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n  \u003cdiv style=\"border-top:1px solid #d9d9d9;border-bottom:1px solid #d9d9d9;\"\u003e\n    \u003cdiv style=\"padding:12px 0;border-bottom:1px solid #e5e5e5;\"\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0 0 4px;color:black;\"\u003e\u003cstrong\u003eHow should the analyzer be prepared before a measurement?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0;color:black;\"\u003ePlace it on a firm, level bench, install a clean and dry sample pan, allow at least 30 minutes of powered warm-up, and check or calibrate the weighing system as needed.\u003c\/p\u003e\n\u003c\/div\u003e\n    \u003cdiv style=\"padding:12px 0;border-bottom:1px solid #e5e5e5;\"\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0 0 4px;color:black;\"\u003e\u003cstrong\u003eWhich heating mode should be selected?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0;color:black;\"\u003eUse standard heating for routine samples, gentle heating for heat-sensitive materials, rapid heating for suitable high-moisture samples, and step heating when the validated method requires staged drying.\u003c\/p\u003e\n\u003c\/div\u003e\n    \u003cdiv style=\"padding:12px 0;border-bottom:1px solid #e5e5e5;\"\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0 0 4px;color:black;\"\u003e\u003cstrong\u003eWhy can results vary between repeated tests?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0;color:black;\"\u003eDifferences in sample uniformity, sample amount, preparation, starting chamber conditions, temperature, heating program, or endpoint can change the result. Keep these conditions consistent when comparing tests.\u003c\/p\u003e\n\u003c\/div\u003e\n    \u003cdiv style=\"padding:12px 0;border-bottom:1px solid #e5e5e5;\"\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0 0 4px;color:black;\"\u003e\u003cstrong\u003eDoes the displayed moisture result measure water only?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0;color:black;\"\u003eNot necessarily. The result is based on mass lost during heating and may include volatile substances other than water. Validate the method against an appropriate reference method when water-specific results are required.\u003c\/p\u003e\n\u003c\/div\u003e\n    \u003cdiv style=\"padding:12px 0;\"\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0 0 4px;color:black;\"\u003e\u003cstrong\u003eHow should the analyzer be cleaned?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0;color:black;\"\u003eSwitch off, unplug, and allow the instrument to cool completely. Clean removable parts and exterior surfaces with a soft, lightly dampened lint-free cloth. Do not immerse the instrument, spray liquid onto it, or use abrasive cleaners or organic solvents.\u003c\/p\u003e\n\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cp style=\"font-size:22px;text-align:left;margin:24px 0 10px;color:#9b1c1c;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n  \u003cdiv style=\"box-sizing:border-box;border-left:5px solid #d97706;background-color:#fff7e6;padding:14px 16px;color:black;\"\u003e\n    \u003cul style=\"font-size:16px;line-height:24px;margin:0;padding-left:22px;\"\u003e\n      \u003cli style=\"margin-bottom:8px;\"\u003eUse only the specified 110 V AC, 60 Hz supply and a grounded US power cord. Do not operate the analyzer with damaged wiring or allow liquid to enter the housing or connectors.\u003c\/li\u003e\n      \u003cli style=\"margin-bottom:8px;\"\u003eThe heater, chamber, sample pan, and sample can remain hot after testing. Keep ventilation openings clear, maintain at least 1 m (39.4 in) of overhead clearance, and use suitable tools and heat protection.\u003c\/li\u003e\n      \u003cli style=\"margin-bottom:8px;\"\u003eDo not test explosive materials or samples that may react dangerously. Flammable, solvent-containing, toxic, or corrosive samples require a documented safety assessment and suitable extraction before testing.\u003c\/li\u003e\n      \u003cli style=\"margin-bottom:8px;\"\u003eDo not exceed the instrument capacity. Taring does not increase capacity, and a 100 g calibration weight must never be placed on a 62 g model.\u003c\/li\u003e\n      \u003cli\u003eSwitch off, unplug, and allow the analyzer to cool before cleaning, moving, or connecting accessories. Do not open the housing or attempt internal repairs.\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/body\u003e","brand":"U.S. Solid","offers":[{"title":"Default Title","offer_id":49230421623039,"sku":"JFVM00005-124G","price":4387.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/1_0d048a02-c570-4642-8fbd-20d177fabebf.png?v=1789626694"},{"product_id":"halogen-moisture-analyzer-40-230-c-drying-range-62-g-capacity-0-0001-g-0-001-readability-5-in-touchscreen-rs232-moisture-balance-1","title":"Halogen Moisture Analyzer, 40-230 °C Drying Range, 62 g Capacity, 0.0001 g\/0.001% Readability, 5-in Touchscreen, RS232 Moisture Balance","description":"\u003cbody\u003e\n\u003cstyle\u003e@media only screen and (max-width:600px){.desktop-only{display:none!important}.mobile-only{display:block!important}}@media only screen and (min-width:601px){.mobile-only{display:none!important}}\u003c\/style\u003e\n\u003cdiv class=\"desktop-only\"\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFVM\/coverimage.png\" alt=\"Halogen moisture analyzer cover image\" style=\"display:block;width:100%;height:auto;border:0;\"\u003e\u003cp style=\"font-size:22px;font-family:Arial;text-align:left;margin-top:0;margin-bottom:10px;color:black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:26px;margin:10px 0 0;color:black;font-family:Arial;\"\u003eThe U.S. Solid USS-VM00005-62G halogen moisture analyzer provides a 40 to 230 deg C drying range for loss-on-drying methods, including procedures with setpoints above 200 deg C. It combines sample heating and weighing to calculate moisture and solids content for food powders, grain, feed, plastic pellets and other suitable laboratory materials.\u003cbr\u003e\u003cbr\u003eReview initial and final sample weights, dry basis and wet basis ratios, temperature and elapsed time. User permissions and custom sample identifiers help organize shared testing workflows. Select the temperature and endpoint for the material; mass loss can include volatile substances other than water, and readability describes display increments rather than measurement accuracy.\u003c\/p\u003e\n\u003cdiv style=\"flex:1;padding:0;font-family:Arial;\"\u003e\n\u003cp style=\"font-size:22px;text-align:left;margin-top:20px;margin-bottom:10px;color:black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFVM\/features.png\" alt=\"Halogen moisture analyzer features\" style=\"display:block;width:100%;height:auto;border:0;\"\u003e\u003cp style=\"font-size:22px;text-align:left;margin-top:20px;margin-bottom:10px;color:black;\"\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFVM\/applications.png\" alt=\"Halogen moisture analyzer applications\" style=\"display:block;width:100%;height:auto;border:0;\"\u003e\u003cp style=\"font-size:22px;text-align:left;margin-top:20px;margin-bottom:10px;color:black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"width:100%;overflow-x:auto;\"\u003e\u003ctable style=\"border-collapse:collapse;border:0;width:100%;font-family:Arial;overflow-x:auto;background-color:#FFFFFF;\"\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003eUSS-VM00005-62G\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eCapacity\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e62 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eWeighing Readability\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e0.0001 g\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eMoisture Readability\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e0.001%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eWeighing Repeatability\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003eStandard deviation ≤3d (d=0.0001 g)\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eWeighing Sensor\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003eElectromagnetic force\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eNet Weight\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e8.8 kg\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eHeating Source\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e350 W halogen lamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eTemperature Setting Range\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e40–230 °C (104–446 °F)\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eTemperature Resolution \/ Setting Step\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e0.1 °C \/ 0.1 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eTemperature Sensor \/ Control\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003ePT-1000 \/ PID\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003ePower Supply\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e110 V AC, 60 Hz, grounded US plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eMaximum Instrument Input\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e500 W\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eDisplay\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e5 in color touchscreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eHeating Programs\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003eStandard, gentle, rapid, step\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eStop Modes\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003eAutomatic, timed, manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eTimed Mode Duration\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e1–99 min; 1 second setting increments\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eMethod Storage\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e96 custom methods\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eResult Storage\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003eUp to 2004 completed records\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eUSB Record Backup\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003eUp to 2000 records per HTML export\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eSample Pan Diameter\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e90 mm\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eHeating Chamber Height\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e24.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eInterfaces\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003eRS-232; USB record backup\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eOperating Temperature\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e1–38 °C; ideally 18–25 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eDimensions\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e23.4 × 35 × 20.5 cm\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eCommon Series Features\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003eLive drying curve; user permissions; custom sample identification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cdiv data-section=\"faq-warning\" style=\"width:100%;box-sizing:border-box;font-family:Arial;margin-top:24px;\"\u003e\n  \u003cp style=\"font-size:22px;text-align:left;margin:0 0 10px;color:black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n  \u003cdiv style=\"border-top:1px solid #d9d9d9;border-bottom:1px solid #d9d9d9;\"\u003e\n    \u003cdiv style=\"padding:12px 0;border-bottom:1px solid #e5e5e5;\"\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0 0 4px;color:black;\"\u003e\u003cstrong\u003eHow should the analyzer be prepared before a measurement?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0;color:black;\"\u003ePlace it on a firm, level bench, install a clean and dry sample pan, allow at least 30 minutes of powered warm-up, and check or calibrate the weighing system as needed.\u003c\/p\u003e\n\u003c\/div\u003e\n    \u003cdiv style=\"padding:12px 0;border-bottom:1px solid #e5e5e5;\"\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0 0 4px;color:black;\"\u003e\u003cstrong\u003eWhich heating mode should be selected?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0;color:black;\"\u003eUse standard heating for routine samples, gentle heating for heat-sensitive materials, rapid heating for suitable high-moisture samples, and step heating when the validated method requires staged drying.\u003c\/p\u003e\n\u003c\/div\u003e\n    \u003cdiv style=\"padding:12px 0;border-bottom:1px solid #e5e5e5;\"\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0 0 4px;color:black;\"\u003e\u003cstrong\u003eWhy can results vary between repeated tests?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0;color:black;\"\u003eDifferences in sample uniformity, sample amount, preparation, starting chamber conditions, temperature, heating program, or endpoint can change the result. Keep these conditions consistent when comparing tests.\u003c\/p\u003e\n\u003c\/div\u003e\n    \u003cdiv style=\"padding:12px 0;border-bottom:1px solid #e5e5e5;\"\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0 0 4px;color:black;\"\u003e\u003cstrong\u003eDoes the displayed moisture result measure water only?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0;color:black;\"\u003eNot necessarily. The result is based on mass lost during heating and may include volatile substances other than water. Validate the method against an appropriate reference method when water-specific results are required.\u003c\/p\u003e\n\u003c\/div\u003e\n    \u003cdiv style=\"padding:12px 0;\"\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0 0 4px;color:black;\"\u003e\u003cstrong\u003eHow should the analyzer be cleaned?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0;color:black;\"\u003eSwitch off, unplug, and allow the instrument to cool completely. Clean removable parts and exterior surfaces with a soft, lightly dampened lint-free cloth. Do not immerse the instrument, spray liquid onto it, or use abrasive cleaners or organic solvents.\u003c\/p\u003e\n\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cp style=\"font-size:22px;text-align:left;margin:24px 0 10px;color:#9b1c1c;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n  \u003cdiv style=\"box-sizing:border-box;border-left:5px solid #d97706;background-color:#fff7e6;padding:14px 16px;color:black;\"\u003e\n    \u003cul style=\"font-size:16px;line-height:24px;margin:0;padding-left:22px;\"\u003e\n      \u003cli style=\"margin-bottom:8px;\"\u003eUse only the specified 110 V AC, 60 Hz supply and a grounded US power cord. Do not operate the analyzer with damaged wiring or allow liquid to enter the housing or connectors.\u003c\/li\u003e\n      \u003cli style=\"margin-bottom:8px;\"\u003eThe heater, chamber, sample pan, and sample can remain hot after testing. Keep ventilation openings clear, maintain at least 1 m (39.4 in) of overhead clearance, and use suitable tools and heat protection.\u003c\/li\u003e\n      \u003cli style=\"margin-bottom:8px;\"\u003eDo not test explosive materials or samples that may react dangerously. Flammable, solvent-containing, toxic, or corrosive samples require a documented safety assessment and suitable extraction before testing.\u003c\/li\u003e\n      \u003cli style=\"margin-bottom:8px;\"\u003eDo not exceed the instrument capacity. Taring does not increase capacity, and a 100 g calibration weight must never be placed on a 62 g model.\u003c\/li\u003e\n      \u003cli\u003eSwitch off, unplug, and allow the analyzer to cool before cleaning, moving, or connecting accessories. Do not open the housing or attempt internal repairs.\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mobile-only\"\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFVM\/coverimage.png\" alt=\"Halogen moisture analyzer cover image\" style=\"display:block;width:100%;height:auto;border:0;\"\u003e\u003cp style=\"font-size:22px;text-align:left;margin-top:0;margin-bottom:10px;color:black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:26px;margin:0;color:black;font-family:Arial;\"\u003eThe U.S. Solid USS-VM00005-62G halogen moisture analyzer provides a 40 to 230 deg C drying range for loss-on-drying methods, including procedures with setpoints above 200 deg C. It combines sample heating and weighing to calculate moisture and solids content for food powders, grain, feed, plastic pellets and other suitable laboratory materials.\u003cbr\u003e\u003cbr\u003eReview initial and final sample weights, dry basis and wet basis ratios, temperature and elapsed time. User permissions and custom sample identifiers help organize shared testing workflows. Select the temperature and endpoint for the material; mass loss can include volatile substances other than water, and readability describes display increments rather than measurement accuracy.\u003c\/p\u003e\n\u003cdiv style=\"flex:1;padding:0;font-family:Arial;\"\u003e\n\u003cp style=\"font-size:22px;text-align:left;margin-top:20px;margin-bottom:10px;color:black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFVM\/features.png\" alt=\"Halogen moisture analyzer features\" style=\"display:block;width:100%;height:auto;border:0;\"\u003e\u003cp style=\"font-size:22px;text-align:left;margin-top:20px;margin-bottom:10px;color:black;\"\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFVM\/applications.png\" alt=\"Halogen moisture analyzer applications\" style=\"display:block;width:100%;height:auto;border:0;\"\u003e\u003cp style=\"font-size:22px;text-align:left;margin-top:20px;margin-bottom:10px;color:black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"width:100%;overflow-x:auto;\"\u003e\u003ctable style=\"border-collapse:collapse;border:0;width:100%;font-family:Arial;overflow-x:auto;background-color:#FFFFFF;\"\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003eUSS-VM00005-62G\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eCapacity\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e62 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eWeighing Readability\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e0.0001 g\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eMoisture Readability\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e0.001%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eWeighing Repeatability\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003eStandard deviation ≤3d (d=0.0001 g)\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eWeighing Sensor\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003eElectromagnetic force\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eNet Weight\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e8.8 kg\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eHeating Source\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e350 W halogen lamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eTemperature Setting Range\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e40–230 °C (104–446 °F)\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eTemperature Resolution \/ Setting Step\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e0.1 °C \/ 0.1 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eTemperature Sensor \/ Control\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003ePT-1000 \/ PID\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003ePower Supply\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e110 V AC, 60 Hz, grounded US plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eMaximum Instrument Input\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e500 W\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eDisplay\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e5 in color touchscreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eHeating Programs\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003eStandard, gentle, rapid, step\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eStop Modes\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003eAutomatic, timed, manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eTimed Mode Duration\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e1–99 min; 1 second setting increments\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eMethod Storage\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e96 custom methods\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eResult Storage\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003eUp to 2004 completed records\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eUSB Record Backup\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003eUp to 2000 records per HTML export\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eSample Pan Diameter\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e90 mm\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eHeating Chamber Height\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e24.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eInterfaces\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003eRS-232; USB record backup\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eOperating Temperature\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e1–38 °C; ideally 18–25 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eDimensions\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e23.4 × 35 × 20.5 cm\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eCommon Series Features\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003eLive drying curve; user permissions; custom sample identification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cdiv data-section=\"faq-warning\" style=\"width:100%;box-sizing:border-box;font-family:Arial;margin-top:24px;\"\u003e\n  \u003cp style=\"font-size:22px;text-align:left;margin:0 0 10px;color:black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n  \u003cdiv style=\"border-top:1px solid #d9d9d9;border-bottom:1px solid #d9d9d9;\"\u003e\n    \u003cdiv style=\"padding:12px 0;border-bottom:1px solid #e5e5e5;\"\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0 0 4px;color:black;\"\u003e\u003cstrong\u003eHow should the analyzer be prepared before a measurement?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0;color:black;\"\u003ePlace it on a firm, level bench, install a clean and dry sample pan, allow at least 30 minutes of powered warm-up, and check or calibrate the weighing system as needed.\u003c\/p\u003e\n\u003c\/div\u003e\n    \u003cdiv style=\"padding:12px 0;border-bottom:1px solid #e5e5e5;\"\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0 0 4px;color:black;\"\u003e\u003cstrong\u003eWhich heating mode should be selected?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0;color:black;\"\u003eUse standard heating for routine samples, gentle heating for heat-sensitive materials, rapid heating for suitable high-moisture samples, and step heating when the validated method requires staged drying.\u003c\/p\u003e\n\u003c\/div\u003e\n    \u003cdiv style=\"padding:12px 0;border-bottom:1px solid #e5e5e5;\"\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0 0 4px;color:black;\"\u003e\u003cstrong\u003eWhy can results vary between repeated tests?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0;color:black;\"\u003eDifferences in sample uniformity, sample amount, preparation, starting chamber conditions, temperature, heating program, or endpoint can change the result. Keep these conditions consistent when comparing tests.\u003c\/p\u003e\n\u003c\/div\u003e\n    \u003cdiv style=\"padding:12px 0;border-bottom:1px solid #e5e5e5;\"\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0 0 4px;color:black;\"\u003e\u003cstrong\u003eDoes the displayed moisture result measure water only?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0;color:black;\"\u003eNot necessarily. The result is based on mass lost during heating and may include volatile substances other than water. Validate the method against an appropriate reference method when water-specific results are required.\u003c\/p\u003e\n\u003c\/div\u003e\n    \u003cdiv style=\"padding:12px 0;\"\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0 0 4px;color:black;\"\u003e\u003cstrong\u003eHow should the analyzer be cleaned?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0;color:black;\"\u003eSwitch off, unplug, and allow the instrument to cool completely. Clean removable parts and exterior surfaces with a soft, lightly dampened lint-free cloth. Do not immerse the instrument, spray liquid onto it, or use abrasive cleaners or organic solvents.\u003c\/p\u003e\n\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cp style=\"font-size:22px;text-align:left;margin:24px 0 10px;color:#9b1c1c;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n  \u003cdiv style=\"box-sizing:border-box;border-left:5px solid #d97706;background-color:#fff7e6;padding:14px 16px;color:black;\"\u003e\n    \u003cul style=\"font-size:16px;line-height:24px;margin:0;padding-left:22px;\"\u003e\n      \u003cli style=\"margin-bottom:8px;\"\u003eUse only the specified 110 V AC, 60 Hz supply and a grounded US power cord. Do not operate the analyzer with damaged wiring or allow liquid to enter the housing or connectors.\u003c\/li\u003e\n      \u003cli style=\"margin-bottom:8px;\"\u003eThe heater, chamber, sample pan, and sample can remain hot after testing. Keep ventilation openings clear, maintain at least 1 m (39.4 in) of overhead clearance, and use suitable tools and heat protection.\u003c\/li\u003e\n      \u003cli style=\"margin-bottom:8px;\"\u003eDo not test explosive materials or samples that may react dangerously. Flammable, solvent-containing, toxic, or corrosive samples require a documented safety assessment and suitable extraction before testing.\u003c\/li\u003e\n      \u003cli style=\"margin-bottom:8px;\"\u003eDo not exceed the instrument capacity. Taring does not increase capacity, and a 100 g calibration weight must never be placed on a 62 g model.\u003c\/li\u003e\n      \u003cli\u003eSwitch off, unplug, and allow the analyzer to cool before cleaning, moving, or connecting accessories. Do not open the housing or attempt internal repairs.\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/body\u003e","brand":"U.S. Solid","offers":[{"title":"Default Title","offer_id":49230425424127,"sku":"JFVM00005-62G","price":4176.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/1_10c24d99-1a4d-4c21-aeeb-e7a37e45eb45.png?v=1789626696"}],"url":"https:\/\/ussolid.com\/collections\/moisture-analyzer-html.oembed?page=2","provider":"U.S. Solid","version":"1.0","type":"link"}