{"title":"UPVC","description":"","products":[{"product_id":"1-upvc-motorized-ball-valve-9-36v-ac-dc-plastic-electrical-ball-valve-with-full-port-2-wire-auto-return-normally-closed-html","title":"1\" UPVC Motorized Ball Valve - 9-36V AC\/DC Plastic Electrical Ball Valve with Full Port, 2 Wire Auto Return, Normally Closed","description":"\u003cbody\u003e \n\n\n    \u003cstyle\u003e\n        @media only screen and (max-width: 600px) {\n        }\n    \u003c\/style\u003e\n\n\n    \u003cdiv class=\"desktop-only\"\u003e\n        \u003c!--  --\u003e\n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; line-height: 26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 10px; color: black; font-family: Arial;\"\u003eMotorized ball valves are a vital piece of equipment in numerous applications. This model opens and closes in 6-8 seconds, and remains in its new position while expending almost no energy. This is a key difference between motorized ball valves and many solenoid valves. Most solenoid valves are energized continuously when in a new position, while motorized ball valves expend energy only when changing from open to close, or vice versa.\u003cbr\u003eThe 2 wire auto return model is perfect for situations where the valve needs to be closed in case of power loss. The valve can be energized to open, and left hooked up, with negligible energy used once fully opened. To close, simply shutoff power to the valve. This valve is convenient because it can be operated with a simple on off switch. When on, it will remain open, when turned off (or power is lost for some other reason) the valve automatically closes.\u003c\/p\u003e\n        \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/1.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n             \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n    \u003ctable style=\"border-collapse: collapse;\n                  border: 0px;\n                  width: 100%;\n                  font-family: Arial;\n                  overflow-x: auto;\n                  background-color: #FFFFFF;\"\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"width: 100%;text-align: left;\n                       padding: 0px;\n                       font-size: 16px;\n                       border: 0;\n                       background-color: #FFFFFF;\"\u003e\n                \u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 1\" style=\"width: 100%;height: 100%;\"\u003e\n            \u003c\/td\u003e\n            \u003ctd style=\"width: 100%;text-align: left;\n                       padding: 0px;\n                       font-size: 16px;\n                       border: 0;\n                       background-color: #FFFFFF;\"\u003e\n                \u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 1\" style=\"width: 100%;height: 100%;\"\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/table\u003e\n\u003c\/div\u003e\n          \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e \n \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV00093\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eU.S. Solid\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e2 Wire Auto Return\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eUPVC\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e6 - 8 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e9-36V AC\/DC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e5 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e2 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1°C to 55°C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e50,000 to 80,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eFull\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\/G\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNormally Closed\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1°C to 50°C\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eIP65\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/CE\/CE-EMC.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP65 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYES. The motorized ball valve is made of lead-free UPVC.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n    \u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP65 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP65. The first digit 6 indicates complete dust - tightness. The second digit 5 means protection against water jets from any direction. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/valve%20model.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/JFMSV-User-manual.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n    \u003c\/div\u003e\n    \u003cdiv class=\"mobile-only\"\u003e\n        \u003c!--  --\u003e\n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; line-height:26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 0px; color: black; font-family: Arial;\"\u003eMotorized ball valves are a vital piece of equipment in numerous applications. This model opens and closes in 6-8 seconds, and remains in its new position while expending almost no energy. This is a key difference between motorized ball valves and many solenoid valves. Most solenoid valves are energized continuously when in a new position, while motorized ball valves expend energy only when changing from open to close, or vice versa.\u003cbr\u003eThe 2 wire auto return model is perfect for situations where the valve needs to be closed in case of power loss. The valve can be energized to open, and left hooked up, with negligible energy used once fully opened. To close, simply shutoff power to the valve. This valve is convenient because it can be operated with a simple on off switch. When on, it will remain open, when turned off (or power is lost for some other reason) the valve automatically closes.\u003c\/p\u003e\n            \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/1.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-bottom:10px; margin-top:20px; color: black;\"\u003e\u003cstrong\u003eAPPLICATION\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n    \u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 1\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n    \u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 1\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n\u003c\/div\u003e\n      \u003cp style=\"font-size: 16px; text-align: left; margin-bottom:10px; margin-top:20px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV00093\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eU.S. Solid\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e2 Wire Auto Return\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eUPVC\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e6 - 8 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e9-36V AC\/DC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e5 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e2 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1°C to 55°C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e50,000 to 80,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eFull\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\/G\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNormally Closed\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1°C to 50°C\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eIP65\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/CE\/CE-EMC.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP65 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYES. The motorized ball valve is made of lead-free UPVC.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n    \u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP65 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP65. The first digit 6 indicates complete dust - tightness. The second digit 5 means protection against water jets from any direction. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/valve%20model.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material-APP.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/JFMSV-User-manual.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n    \u003cscript\u003e\n\n        \/\/ (User Agent)\n        const isMobile = window.matchMedia(\"only screen and (max-width: 600px)\").matches;\n        const desktopContent = document.querySelector('.desktop-only');\n        const mobileContent = document.querySelector('.mobile-only');\n\n        if (isMobile) {\n            \/\/ \n            console.log('');\n            \/\/ ，\n            desktopContent.style.display = 'none';\n            mobileContent.style.display = 'block';\n        } else {\n            \/\/ \n            console.log('');            \n            \/\/ ，\n            desktopContent.style.display = 'block';\n            mobileContent.style.display = 'none';\n        }\n    \u003c\/script\u003e\n\n\n\n\u003c\/body\u003e","brand":"U.S. Solid","offers":[{"title":"NPT","offer_id":46918829736191,"sku":"JFMSV00093","price":40.49,"currency_code":"USD","in_stock":true},{"title":"G","offer_id":46918829768959,"sku":"JFMSV00093-G","price":39.79,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/1__72601.1697100473.1280.1280.jpg?v=1731291535"},{"product_id":"1-2-upvc-motorized-ball-valve-9-36v-ac-dc-plastic-electrical-ball-valve-with-full-port-2-wire-auto-return-normally-closed-html","title":"1\/2\" UPVC Motorized Ball Valve - 9-36V AC\/DC Plastic Electrical Ball Valve with Full Port, 2 Wire Auto Return, Normally Closed","description":"\u003cbody\u003e \n\n\n    \u003cstyle\u003e\n        @media only screen and (max-width: 600px) {\n        }\n    \u003c\/style\u003e\n\n\n    \u003cdiv class=\"desktop-only\"\u003e\n        \n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; line-height: 26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 10px; color: black; font-family: Arial;\"\u003eMotorized ball valves are a vital piece of equipment in numerous applications. This model opens and closes in 6-8 seconds, and remains in its new position while expending almost no energy. This is a key difference between motorized ball valves and many solenoid valves. Most solenoid valves are energized continuously when in a new position, while motorized ball valves expend energy only when changing from open to close, or vice versa.\u003cbr\u003eThe 2 wire auto return model is perfect for situations where the valve needs to be closed in case of power loss. The valve can be energized to open, and left hooked up, with negligible energy used once fully opened. To close, simply shutoff power to the valve. This valve is convenient because it can be operated with a simple on off switch. When on, it will remain open, when turned off (or power is lost for some other reason) the valve automatically closes.\u003c\/p\u003e\n        \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/1.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n             \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n    \u003ctable style=\"border-collapse: collapse;\n                  border: 0px;\n                  width: 100%;\n                  font-family: Arial;\n                  overflow-x: auto;\n                  background-color: #FFFFFF;\"\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"width: 100%;text-align: left;\n                       padding: 0px;\n                       font-size: 16px;\n                       border: 0;\n                       background-color: #FFFFFF;\"\u003e\n                \u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 1\/2\" style=\"width: 100%;height: 100%;\"\u003e\n            \u003c\/td\u003e\n            \u003ctd style=\"width: 100%;text-align: left;\n                       padding: 0px;\n                       font-size: 16px;\n                       border: 0;\n                       background-color: #FFFFFF;\"\u003e\n                \u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 1\/2\" style=\"width: 100%;height: 100%;\"\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/table\u003e\n\u003c\/div\u003e\n          \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e \n \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV00091\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eU.S. Solid\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1\/2\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e2 Wire Auto Return\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eUPVC\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e6 - 8 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e9-36V AC\/DC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e5 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e2 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1°C to 55°C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e50,000 to 80,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eFull\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\/G\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNormally Closed\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1°C to 50°C\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eIP65\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/CE\/CE-EMC.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP65 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYES. The motorized ball valve is made of lead-free UPVC.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n    \u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP65 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP65. The first digit 6 indicates complete dust - tightness. The second digit 5 means protection against water jets from any direction. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/valve%20model.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/JFMSV-User-manual.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n    \u003c\/div\u003e\n    \u003cdiv class=\"mobile-only\"\u003e\n        \n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; line-height:26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 0px; color: black; font-family: Arial;\"\u003eMotorized ball valves are a vital piece of equipment in numerous applications. This model opens and closes in 6-8 seconds, and remains in its new position while expending almost no energy. This is a key difference between motorized ball valves and many solenoid valves. Most solenoid valves are energized continuously when in a new position, while motorized ball valves expend energy only when changing from open to close, or vice versa.\u003cbr\u003eThe 2 wire auto return model is perfect for situations where the valve needs to be closed in case of power loss. The valve can be energized to open, and left hooked up, with negligible energy used once fully opened. To close, simply shutoff power to the valve. This valve is convenient because it can be operated with a simple on off switch. When on, it will remain open, when turned off (or power is lost for some other reason) the valve automatically closes.\u003c\/p\u003e\n            \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/1.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-bottom:10px; margin-top:20px; color: black;\"\u003e\u003cstrong\u003eAPPLICATION\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n    \u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 1\/2\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n    \u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 1\/2\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n\u003c\/div\u003e\n      \u003cp style=\"font-size: 16px; text-align: left; margin-bottom:10px; margin-top:20px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV00091\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eU.S. Solid\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1\/2\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e2 Wire Auto Return\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eUPVC\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e6 - 8 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e9-36V AC\/DC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e5 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e2 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1°C to 55°C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e50,000 to 80,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eFull\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\/G\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNormally Closed\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1°C to 50°C\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eIP65\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/CE\/CE-EMC.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP65 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYES. The motorized ball valve is made of lead-free UPVC.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n    \u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP65 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP65. The first digit 6 indicates complete dust - tightness. The second digit 5 means protection against water jets from any direction. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/valve%20model.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material-APP.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/JFMSV-User-manual.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n    \u003cscript\u003e\n\n        \n        const isMobile = window.matchMedia(\"only screen and (max-width: 600px)\").matches;\n        const desktopContent = document.querySelector('.desktop-only');\n        const mobileContent = document.querySelector('.mobile-only');\n\n        if (isMobile) {\n            \n            console.log('');\n           \n            desktopContent.style.display = 'none';\n            mobileContent.style.display = 'block';\n        } else {\n           \n            console.log('');            \n            \n            desktopContent.style.display = 'block';\n            mobileContent.style.display = 'none';\n        }\n    \u003c\/script\u003e\n\n\n\n\u003c\/body\u003e","brand":"U.S. Solid","offers":[{"title":"NPT","offer_id":46892341199103,"sku":"JFMSV00091","price":33.49,"currency_code":"USD","in_stock":true},{"title":"G","offer_id":46892341231871,"sku":"JFMSV00091-G","price":32.39,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/1__04005.1697099836.1280.1280.jpg?v=1731291530"},{"product_id":"3-4-upvc-motorized-ball-valve-9-36v-ac-dc-plastic-electrical-ball-valve-with-full-port-2-wire-auto-return-normally-closed-html","title":"3\/4\" UPVC Motorized Ball Valve - 9-36V AC\/DC Plastic Electrical Ball Valve with Full Port, 2 Wire Auto Return, Normally Closed","description":"\u003cbody\u003e \n\n\n    \u003cstyle\u003e\n        @media only screen and (max-width: 600px) {\n        }\n    \u003c\/style\u003e\n\n\n    \u003cdiv class=\"desktop-only\"\u003e\n        \u003c!--  --\u003e\n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; line-height: 26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 10px; color: black; font-family: Arial;\"\u003eMotorized ball valves are a vital piece of equipment in numerous applications. This model opens and closes in 6-8 seconds, and remains in its new position while expending almost no energy. This is a key difference between motorized ball valves and many solenoid valves. Most solenoid valves are energized continuously when in a new position, while motorized ball valves expend energy only when changing from open to close, or vice versa.\u003cbr\u003eThe 2 wire auto return model is perfect for situations where the valve needs to be closed in case of power loss. The valve can be energized to open, and left hooked up, with negligible energy used once fully opened. To close, simply shutoff power to the valve. This valve is convenient because it can be operated with a simple on off switch. When on, it will remain open, when turned off (or power is lost for some other reason) the valve automatically closes.\u003c\/p\u003e\n        \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/1.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n             \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n    \u003ctable style=\"border-collapse: collapse;\n                  border: 0px;\n                  width: 100%;\n                  font-family: Arial;\n                  overflow-x: auto;\n                  background-color: #FFFFFF;\"\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"width: 100%;text-align: left;\n                       padding: 0px;\n                       font-size: 16px;\n                       border: 0;\n                       background-color: #FFFFFF;\"\u003e\n                \u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 3\/4\" style=\"width: 100%;height: 100%;\"\u003e\n            \u003c\/td\u003e\n            \u003ctd style=\"width: 100%;text-align: left;\n                       padding: 0px;\n                       font-size: 16px;\n                       border: 0;\n                       background-color: #FFFFFF;\"\u003e\n                \u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 3\/4\" style=\"width: 100%;height: 100%;\"\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/table\u003e\n\u003c\/div\u003e\n          \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e \n \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV00092\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eU.S. Solid\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e3\/4\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e2 Wire Auto Return\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eUPVC\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e6 - 8 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e9-36V AC\/DC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e5 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e2 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1°C to 55°C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e50,000 to 80,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eFull\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\/G\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNormally Closed\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1°C to 50°C\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eIP65\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/CE\/CE-EMC.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP65 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYES. The motorized ball valve is made of lead-free UPVC.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n    \u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP65 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP65. The first digit 6 indicates complete dust - tightness. The second digit 5 means protection against water jets from any direction. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/valve%20model.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/JFMSV-User-manual.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n    \u003c\/div\u003e\n    \u003cdiv class=\"mobile-only\"\u003e\n        \u003c!--  --\u003e\n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; line-height:26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 0px; color: black; font-family: Arial;\"\u003eMotorized ball valves are a vital piece of equipment in numerous applications. This model opens and closes in 6-8 seconds, and remains in its new position while expending almost no energy. This is a key difference between motorized ball valves and many solenoid valves. Most solenoid valves are energized continuously when in a new position, while motorized ball valves expend energy only when changing from open to close, or vice versa.\u003cbr\u003eThe 2 wire auto return model is perfect for situations where the valve needs to be closed in case of power loss. The valve can be energized to open, and left hooked up, with negligible energy used once fully opened. To close, simply shutoff power to the valve. This valve is convenient because it can be operated with a simple on off switch. When on, it will remain open, when turned off (or power is lost for some other reason) the valve automatically closes.\u003c\/p\u003e\n            \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/1.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-bottom:10px; margin-top:20px; color: black;\"\u003e\u003cstrong\u003eAPPLICATION\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n    \u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 3\/4\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n    \u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 3\/4\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n\u003c\/div\u003e\n      \u003cp style=\"font-size: 16px; text-align: left; margin-bottom:10px; margin-top:20px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV00092\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eU.S. Solid\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e3\/4\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e2 Wire Auto Return\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eUPVC\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e6 - 8 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e9-36V AC\/DC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e5 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e2 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1°C to 55°C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e50,000 to 80,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eFull\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\/G\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNormally Closed\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1°C to 50°C\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eIP65\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/CE\/CE-EMC.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP65 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYES. The motorized ball valve is made of lead-free UPVC.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n    \u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP65 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP65. The first digit 6 indicates complete dust - tightness. The second digit 5 means protection against water jets from any direction. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/valve%20model.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material-APP.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/JFMSV-User-manual.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n    \u003cscript\u003e\n\n        \/\/ (User Agent)\n        const isMobile = window.matchMedia(\"only screen and (max-width: 600px)\").matches;\n        const desktopContent = document.querySelector('.desktop-only');\n        const mobileContent = document.querySelector('.mobile-only');\n\n        if (isMobile) {\n            \/\/ \n            console.log('');\n            \/\/ ，\n            desktopContent.style.display = 'none';\n            mobileContent.style.display = 'block';\n        } else {\n            \/\/ \n            console.log('');            \n            \/\/ ，\n            desktopContent.style.display = 'block';\n            mobileContent.style.display = 'none';\n        }\n    \u003c\/script\u003e\n\n\n\n\u003c\/body\u003e","brand":"U.S. Solid","offers":[{"title":"NPT","offer_id":46918825148671,"sku":"JFMSV00092","price":34.79,"currency_code":"USD","in_stock":true},{"title":"G","offer_id":46918825181439,"sku":"JFMSV00092-G","price":35.19,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/1__59414.1697100117.1280.1280.jpg?v=1731291541"},{"product_id":"3-4-upvc-motorized-ball-valve-110v-ac-plastic-electrical-ball-valve-with-full-port-2-wire-auto-return-normally-closed-html","title":"3\/4\" UPVC Motorized Ball Valve - 85-265V AC Plastic Electrical Ball Valve with Full Port, 2 Wire Auto Return, Normally Closed","description":"\u003cbody\u003e \n\n\n    \u003cstyle\u003e\n        @media only screen and (max-width: 600px) {\n        }\n    \u003c\/style\u003e\n\n\n    \u003cdiv class=\"desktop-only\"\u003e\n        \n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; line-height: 26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 10px; color: black; font-family: Arial;\"\u003eMotorized ball valves are a vital piece of equipment in numerous applications. This model opens and closes in 6-8 seconds, and remains in its new position while expending almost no energy. This is a key difference between motorized ball valves and many solenoid valves. Most solenoid valves are energized continuously when in a new position, while motorized ball valves expend energy only when changing from open to close, or vice versa.\u003cbr\u003eThe 2 wire auto return model is perfect for situations where the valve needs to be closed in case of power loss. The valve can be energized to open, and left hooked up, with negligible energy used once fully opened. To close, simply shutoff power to the valve. This valve is convenient because it can be operated with a simple on off switch. When on, it will remain open, when turned off (or power is lost for some other reason) the valve automatically closes.\u003c\/p\u003e\n        \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/1.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n             \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n    \u003ctable style=\"border-collapse: collapse;\n                  border: 0px;\n                  width: 100%;\n                  font-family: Arial;\n                  overflow-x: auto;\n                  background-color: #FFFFFF;\"\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"width: 100%;text-align: left;\n                       padding: 0px;\n                       font-size: 16px;\n                       border: 0;\n                       background-color: #FFFFFF;\"\u003e\n                \u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 3\/4\" style=\"width: 100%;height: 100%;\"\u003e\n            \u003c\/td\u003e\n            \u003ctd style=\"width: 100%;text-align: left;\n                       padding: 0px;\n                       font-size: 16px;\n                       border: 0;\n                       background-color: #FFFFFF;\"\u003e\n                \u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 3\/4\" style=\"width: 100%;height: 100%;\"\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/table\u003e\n\u003c\/div\u003e\n          \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e \n \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV00098\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eU.S. Solid\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e3\/4\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e2 Wire Auto Return\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eUPVC\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e6 - 8 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eAC 85-265V\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e10 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e2 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1°C to 55°C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e50,000 to 80,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eFull\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\/G\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNormally Closed\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1°C to 50°C\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eIP65\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/CE.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP65 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYES. The motorized ball valve is made of lead-free UPVC.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n    \u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP65 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP65. The first digit 6 indicates complete dust - tightness. The second digit 5 means protection against water jets from any direction. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/valve%20model.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/JFMSV-User-manual.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n    \u003c\/div\u003e\n    \u003cdiv class=\"mobile-only\"\u003e\n        \n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; line-height:26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 0px; color: black; font-family: Arial;\"\u003eMotorized ball valves are a vital piece of equipment in numerous applications. This model opens and closes in 6-8 seconds, and remains in its new position while expending almost no energy. This is a key difference between motorized ball valves and many solenoid valves. Most solenoid valves are energized continuously when in a new position, while motorized ball valves expend energy only when changing from open to close, or vice versa.\u003cbr\u003eThe 2 wire auto return model is perfect for situations where the valve needs to be closed in case of power loss. The valve can be energized to open, and left hooked up, with negligible energy used once fully opened. To close, simply shutoff power to the valve. This valve is convenient because it can be operated with a simple on off switch. When on, it will remain open, when turned off (or power is lost for some other reason) the valve automatically closes.\u003c\/p\u003e\n            \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/1.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-bottom:10px; margin-top:20px; color: black;\"\u003e\u003cstrong\u003eAPPLICATION\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n    \u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 3\/4\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n    \u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 3\/4\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n\u003c\/div\u003e\n      \u003cp style=\"font-size: 16px; text-align: left; margin-bottom:10px; margin-top:20px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV00098\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eU.S. Solid\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e3\/4\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e2 Wire Auto Return\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eUPVC\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e6 - 8 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eAC 85-265V\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e10 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e2 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1°C to 55°C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e50,000 to 80,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eFull\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\/G\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNormally Closed\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1°C to 50°C\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eIP65\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/CE.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP65 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYES. The motorized ball valve is made of lead-free UPVC.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n    \u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP65 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP65. The first digit 6 indicates complete dust - tightness. The second digit 5 means protection against water jets from any direction. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/valve%20model.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material-APP.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/JFMSV-User-manual.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n    \u003cscript\u003e\n\n        const isMobile = window.matchMedia(\"only screen and (max-width: 600px)\").matches;\n        const desktopContent = document.querySelector('.desktop-only');\n        const mobileContent = document.querySelector('.mobile-only');\n\n        if (isMobile) {\n            \n            console.log('');\n            \n            desktopContent.style.display = 'none';\n            mobileContent.style.display = 'block';\n        } else {\n            \n            console.log('');            \n            \n            desktopContent.style.display = 'block';\n            mobileContent.style.display = 'none';\n        }\n    \u003c\/script\u003e\n\n\n\n\u003c\/body\u003e","brand":"U.S. Solid","offers":[{"title":"NPT","offer_id":46918702170367,"sku":"JFMSV00098","price":41.89,"currency_code":"USD","in_stock":true},{"title":"G","offer_id":46918702203135,"sku":"JFMSV00098-G","price":41.89,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/1__70208.1729581611.1280.1280.jpg?v=1731291597"},{"product_id":"1-upvc-motorized-ball-valve-normally-open-9-36v-ac-dc-plastic-electrical-ball-valve-with-full-port-2-wire-auto-return-html","title":"1\" UPVC Motorized Ball Valve - Normally Open 9-36V AC\/DC Plastic Electrical Ball Valve with Full Port, 2 Wire Auto Return","description":"\u003cbody\u003e \n\n\n    \u003cstyle\u003e\n        @media only screen and (max-width: 600px) {\n        }\n    \u003c\/style\u003e\n\n\n    \u003cdiv class=\"desktop-only\"\u003e\n        \n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; line-height: 26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 10px; color: black; font-family: Arial;\"\u003eMotorized ball valves are a vital piece of equipment in numerous applications. This model opens and closes in 6-8 seconds, and remains in its new position while expending almost no energy. This is a key difference between motorized ball valves and many solenoid valves. Most solenoid valves are energized continuously when in a new position, while motorized ball valves expend energy only when changing from open to close, or vice versa.\u003cbr\u003eThe 2 wire auto return model is perfect for situations where the valve needs to be closed in case of power loss. The valve can be energized to open, and left hooked up, with negligible energy used once fully opened. To close, simply shutoff power to the valve. This valve is convenient because it can be operated with a simple on off switch. When on, it will remain open, when turned off (or power is lost for some other reason) the valve automatically closes.\u003c\/p\u003e\n        \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/1.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n             \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n    \u003ctable style=\"border-collapse: collapse;\n                  border: 0px;\n                  width: 100%;\n                  font-family: Arial;\n                  overflow-x: auto;\n                  background-color: #FFFFFF;\"\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"width: 100%;text-align: left;\n                       padding: 0px;\n                       font-size: 16px;\n                       border: 0;\n                       background-color: #FFFFFF;\"\u003e\n                \u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 1\" style=\"width: 100%;height: 100%;\"\u003e\n            \u003c\/td\u003e\n            \u003ctd style=\"width: 100%;text-align: left;\n                       padding: 0px;\n                       font-size: 16px;\n                       border: 0;\n                       background-color: #FFFFFF;\"\u003e\n                \u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 1\" style=\"width: 100%;height: 100%;\"\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/table\u003e\n\u003c\/div\u003e\n          \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e \n \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV00096\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eU.S. Solid\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e2 Wire Auto Return\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eUPVC\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e6 - 8 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e9-36V AC\/DC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e10 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e2 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1°C to 55°C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e50,000 to 80,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eFull\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\/G\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNormally Open\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1°C to 50°C\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eIP65\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/CE\/CE-EMC.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP65 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYES. The motorized ball valve is made of lead-free UPVC.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n    \u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP65 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP65. The first digit 6 indicates complete dust - tightness. The second digit 5 means protection against water jets from any direction. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/valve%20model.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/JFMSV-User-manual.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n    \u003c\/div\u003e\n    \u003cdiv class=\"mobile-only\"\u003e\n        \n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; line-height:26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 0px; color: black; font-family: Arial;\"\u003eMotorized ball valves are a vital piece of equipment in numerous applications. This model opens and closes in 6-8 seconds, and remains in its new position while expending almost no energy. This is a key difference between motorized ball valves and many solenoid valves. Most solenoid valves are energized continuously when in a new position, while motorized ball valves expend energy only when changing from open to close, or vice versa.\u003cbr\u003eThe 2 wire auto return model is perfect for situations where the valve needs to be closed in case of power loss. The valve can be energized to open, and left hooked up, with negligible energy used once fully opened. To close, simply shutoff power to the valve. This valve is convenient because it can be operated with a simple on off switch. When on, it will remain open, when turned off (or power is lost for some other reason) the valve automatically closes.\u003c\/p\u003e\n            \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/1.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-bottom:10px; margin-top:20px; color: black;\"\u003e\u003cstrong\u003eAPPLICATION\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n    \u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 1\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n    \u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 1\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n\u003c\/div\u003e\n      \u003cp style=\"font-size: 16px; text-align: left; margin-bottom:10px; margin-top:20px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV00096\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eU.S. Solid\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e2 Wire Auto Return\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eUPVC\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e6 - 8 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e9-36V AC\/DC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e10 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e2 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1°C to 55°C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e50,000 to 80,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eFull\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\/G\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNormally Open\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1°C to 50°C\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eIP65\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/CE\/CE-EMC.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP65 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYES. The motorized ball valve is made of lead-free UPVC.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n    \u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP65 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP65. The first digit 6 indicates complete dust - tightness. The second digit 5 means protection against water jets from any direction. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/valve%20model.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material-APP.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/JFMSV-User-manual.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n    \u003cscript\u003e\n\n        \n        const isMobile = window.matchMedia(\"only screen and (max-width: 600px)\").matches;\n        const desktopContent = document.querySelector('.desktop-only');\n        const mobileContent = document.querySelector('.mobile-only');\n\n        if (isMobile) {\n            \n            console.log('');\n            \n            desktopContent.style.display = 'none';\n            mobileContent.style.display = 'block';\n        } else {\n           \n            console.log('');            \n            \n            desktopContent.style.display = 'block';\n            mobileContent.style.display = 'none';\n        }\n    \u003c\/script\u003e\n\n\n\n\u003c\/body\u003e","brand":"U.S. Solid","offers":[{"title":"NPT","offer_id":46918700073215,"sku":"JFMSV00096","price":43.59,"currency_code":"USD","in_stock":true},{"title":"G","offer_id":46918700105983,"sku":"JFMSV00096-G","price":38.89,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/1__54261.1729581164.1280.1280.jpg?v=1731291600"},{"product_id":"1-2-upvc-motorized-ball-valve-normally-open-9-36v-ac-dc-plastic-electrical-ball-valve-with-full-port-2-wire-auto-return-html","title":"1\/2\" UPVC Motorized Ball Valve - Normally Open 9-36V AC\/DC Plastic Electrical Ball Valve with Full Port, 2 Wire Auto Return","description":"\u003cbody\u003e \n\n\n    \u003cstyle\u003e\n        @media only screen and (max-width: 600px) {\n        }\n    \u003c\/style\u003e\n\n\n    \u003cdiv class=\"desktop-only\"\u003e\n       \n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; line-height: 26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 10px; color: black; font-family: Arial;\"\u003eMotorized ball valves are a vital piece of equipment in numerous applications. This model opens and closes in 6-8 seconds, and remains in its new position while expending almost no energy. This is a key difference between motorized ball valves and many solenoid valves. Most solenoid valves are energized continuously when in a new position, while motorized ball valves expend energy only when changing from open to close, or vice versa.\u003cbr\u003eThe 2 wire auto return model is perfect for situations where the valve needs to be closed in case of power loss. The valve can be energized to open, and left hooked up, with negligible energy used once fully opened. To close, simply shutoff power to the valve. This valve is convenient because it can be operated with a simple on off switch. When on, it will remain open, when turned off (or power is lost for some other reason) the valve automatically closes.\u003c\/p\u003e\n        \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/1.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n             \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n    \u003ctable style=\"border-collapse: collapse;\n                  border: 0px;\n                  width: 100%;\n                  font-family: Arial;\n                  overflow-x: auto;\n                  background-color: #FFFFFF;\"\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"width: 100%;text-align: left;\n                       padding: 0px;\n                       font-size: 16px;\n                       border: 0;\n                       background-color: #FFFFFF;\"\u003e\n                \u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 1\/2\" style=\"width: 100%;height: 100%;\"\u003e\n            \u003c\/td\u003e\n            \u003ctd style=\"width: 100%;text-align: left;\n                       padding: 0px;\n                       font-size: 16px;\n                       border: 0;\n                       background-color: #FFFFFF;\"\u003e\n                \u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 1\/2\" style=\"width: 100%;height: 100%;\"\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/table\u003e\n\u003c\/div\u003e\n          \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e \n \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV00094\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eU.S. Solid\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1\/2\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e2 Wire Auto Return\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eUPVC\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e6 - 8 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e9-36V AC\/DC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e5 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e2 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1°C to 55°C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e50,000 to 80,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eFull\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\/G\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNormally Open\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1°C to 50°C\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eIP65\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/CE\/CE-EMC.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP65 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYES. The motorized ball valve is made of lead-free UPVC.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n    \u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP65 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP65. The first digit 6 indicates complete dust - tightness. The second digit 5 means protection against water jets from any direction. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/valve%20model.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/JFMSV-User-manual.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n    \u003c\/div\u003e\n    \u003cdiv class=\"mobile-only\"\u003e\n        \n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; line-height:26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 0px; color: black; font-family: Arial;\"\u003eMotorized ball valves are a vital piece of equipment in numerous applications. This model opens and closes in 6-8 seconds, and remains in its new position while expending almost no energy. This is a key difference between motorized ball valves and many solenoid valves. Most solenoid valves are energized continuously when in a new position, while motorized ball valves expend energy only when changing from open to close, or vice versa.\u003cbr\u003eThe 2 wire auto return model is perfect for situations where the valve needs to be closed in case of power loss. The valve can be energized to open, and left hooked up, with negligible energy used once fully opened. To close, simply shutoff power to the valve. This valve is convenient because it can be operated with a simple on off switch. When on, it will remain open, when turned off (or power is lost for some other reason) the valve automatically closes.\u003c\/p\u003e\n            \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/1.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-bottom:10px; margin-top:20px; color: black;\"\u003e\u003cstrong\u003eAPPLICATION\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n    \u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 1\/2\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n    \u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 1\/2\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n\u003c\/div\u003e\n      \u003cp style=\"font-size: 16px; text-align: left; margin-bottom:10px; margin-top:20px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV00094\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eU.S. Solid\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1\/2\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e2 Wire Auto Return\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eUPVC\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e6 - 8 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e9-36V AC\/DC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e5 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e2 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1°C to 55°C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e50,000 to 80,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eFull\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\/G\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNormally Open\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1°C to 50°C\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eIP65\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/CE\/CE-EMC.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP65 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYES. The motorized ball valve is made of lead-free UPVC.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n    \u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP65 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP65. The first digit 6 indicates complete dust - tightness. The second digit 5 means protection against water jets from any direction. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/valve%20model.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material-APP.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/JFMSV-User-manual.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n    \u003cscript\u003e\n\n       \n        const isMobile = window.matchMedia(\"only screen and (max-width: 600px)\").matches;\n        const desktopContent = document.querySelector('.desktop-only');\n        const mobileContent = document.querySelector('.mobile-only');\n\n        if (isMobile) {\n           \n            console.log('');\n           \n            desktopContent.style.display = 'none';\n            mobileContent.style.display = 'block';\n        } else {\n           \n            console.log('');            \n            \n            desktopContent.style.display = 'block';\n            mobileContent.style.display = 'none';\n        }\n    \u003c\/script\u003e\n\n\n\n\u003c\/body\u003e","brand":"U.S. Solid","offers":[{"title":"NPT","offer_id":46918697419007,"sku":"JFMSV00094","price":33.49,"currency_code":"USD","in_stock":true},{"title":"G","offer_id":46918697451775,"sku":"JFMSV00094-G","price":32.39,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/1__12754.1729581017.1280.1280.jpg?v=1731291601"},{"product_id":"1-2-upvc-motorized-ball-valve-110v-ac-plastic-electrical-ball-valve-with-full-port-2-wire-auto-return-normally-closed-html","title":"1\/2\" UPVC Motorized Ball Valve - 85-265V AC Plastic Electrical Ball Valve with Full Port, 2 Wire Auto Return, Normally Closed","description":"\u003cbody\u003e \n\n\n    \u003cstyle\u003e\n        @media only screen and (max-width: 600px) {\n        }\n    \u003c\/style\u003e\n\n\n    \u003cdiv class=\"desktop-only\"\u003e\n        \n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; line-height: 26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 10px; color: black; font-family: Arial;\"\u003eMotorized ball valves are a vital piece of equipment in numerous applications. This model opens and closes in 6-8 seconds, and remains in its new position while expending almost no energy. This is a key difference between motorized ball valves and many solenoid valves. Most solenoid valves are energized continuously when in a new position, while motorized ball valves expend energy only when changing from open to close, or vice versa.\u003cbr\u003eThe 2 wire auto return model is perfect for situations where the valve needs to be closed in case of power loss. The valve can be energized to open, and left hooked up, with negligible energy used once fully opened. To close, simply shutoff power to the valve. This valve is convenient because it can be operated with a simple on off switch. When on, it will remain open, when turned off (or power is lost for some other reason) the valve automatically closes.\u003c\/p\u003e\n        \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/1.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n             \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n    \u003ctable style=\"border-collapse: collapse;\n                  border: 0px;\n                  width: 100%;\n                  font-family: Arial;\n                  overflow-x: auto;\n                  background-color: #FFFFFF;\"\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"width: 100%;text-align: left;\n                       padding: 0px;\n                       font-size: 16px;\n                       border: 0;\n                       background-color: #FFFFFF;\"\u003e\n                \u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 1\/2\" style=\"width: 100%;height: 100%;\"\u003e\n            \u003c\/td\u003e\n            \u003ctd style=\"width: 100%;text-align: left;\n                       padding: 0px;\n                       font-size: 16px;\n                       border: 0;\n                       background-color: #FFFFFF;\"\u003e\n                \u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 1\/2\" style=\"width: 100%;height: 100%;\"\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/table\u003e\n\u003c\/div\u003e\n          \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e \n \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV00097\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eU.S. Solid\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1\/2\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e2 Wire Auto Return\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eUPVC\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e6 - 8 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eAC 85-265V\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e10 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e2 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1°C to 55°C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e50,000 to 80,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eFull\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\/G\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNormally Closed\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1°C to 50°C\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eIP65\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/CE.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP65 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYES. The motorized ball valve is made of lead-free UPVC.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n    \u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP65 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP65. The first digit 6 indicates complete dust - tightness. The second digit 5 means protection against water jets from any direction. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/valve%20model.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/JFMSV-User-manual.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n    \u003c\/div\u003e\n    \u003cdiv class=\"mobile-only\"\u003e\n       \n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; line-height:26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 0px; color: black; font-family: Arial;\"\u003eMotorized ball valves are a vital piece of equipment in numerous applications. This model opens and closes in 6-8 seconds, and remains in its new position while expending almost no energy. This is a key difference between motorized ball valves and many solenoid valves. Most solenoid valves are energized continuously when in a new position, while motorized ball valves expend energy only when changing from open to close, or vice versa.\u003cbr\u003eThe 2 wire auto return model is perfect for situations where the valve needs to be closed in case of power loss. The valve can be energized to open, and left hooked up, with negligible energy used once fully opened. To close, simply shutoff power to the valve. This valve is convenient because it can be operated with a simple on off switch. When on, it will remain open, when turned off (or power is lost for some other reason) the valve automatically closes.\u003c\/p\u003e\n            \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/1.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-bottom:10px; margin-top:20px; color: black;\"\u003e\u003cstrong\u003eAPPLICATION\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n    \u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 1\/2\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n    \u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 1\/2\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n\u003c\/div\u003e\n      \u003cp style=\"font-size: 16px; text-align: left; margin-bottom:10px; margin-top:20px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV00097\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eU.S. Solid\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1\/2\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e2 Wire Auto Return\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eUPVC\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e6 - 8 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eAC 85-265V\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e10 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e2 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1°C to 55°C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e50,000 to 80,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eFull\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\/G\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNormally Closed\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1°C to 50°C\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eIP65\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/CE.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP65 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYES. The motorized ball valve is made of lead-free UPVC.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n    \u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP65 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP65. The first digit 6 indicates complete dust - tightness. The second digit 5 means protection against water jets from any direction. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/valve%20model.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material-APP.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/JFMSV-User-manual.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n    \u003cscript\u003e\n\n        \n        const isMobile = window.matchMedia(\"only screen and (max-width: 600px)\").matches;\n        const desktopContent = document.querySelector('.desktop-only');\n        const mobileContent = document.querySelector('.mobile-only');\n\n        if (isMobile) {\n           \n            console.log('');\n           \n            desktopContent.style.display = 'none';\n            mobileContent.style.display = 'block';\n        } else {\n           \n            console.log('');            \n            \n            desktopContent.style.display = 'block';\n            mobileContent.style.display = 'none';\n        }\n    \u003c\/script\u003e\n\n\n\n\u003c\/body\u003e","brand":"U.S. Solid","offers":[{"title":"NPT","offer_id":46918696108287,"sku":"JFMSV00097","price":40.69,"currency_code":"USD","in_stock":true},{"title":"G","offer_id":46918696141055,"sku":"JFMSV00097-G","price":39.99,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/1__76387.1729578916.1280.1280.jpg?v=1731291601"},{"product_id":"1-upvc-motorized-ball-valve-110v-ac-plastic-electrical-ball-valve-with-full-port-2-wire-auto-return-normally-closed-html","title":"1\" UPVC Motorized Ball Valve - 85-265V AC Plastic Electrical Ball Valve with Full Port, 2 Wire Auto Return, Normally Closed","description":"\u003cbody\u003e \n\n\n    \u003cstyle\u003e\n        @media only screen and (max-width: 600px) {\n        }\n    \u003c\/style\u003e\n\n\n    \u003cdiv class=\"desktop-only\"\u003e\n       \n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; line-height: 26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 10px; color: black; font-family: Arial;\"\u003eMotorized ball valves are a vital piece of equipment in numerous applications. This model opens and closes in 6-8 seconds, and remains in its new position while expending almost no energy. This is a key difference between motorized ball valves and many solenoid valves. Most solenoid valves are energized continuously when in a new position, while motorized ball valves expend energy only when changing from open to close, or vice versa.\u003cbr\u003eThe 2 wire auto return model is perfect for situations where the valve needs to be closed in case of power loss. The valve can be energized to open, and left hooked up, with negligible energy used once fully opened. To close, simply shutoff power to the valve. This valve is convenient because it can be operated with a simple on off switch. When on, it will remain open, when turned off (or power is lost for some other reason) the valve automatically closes.\u003c\/p\u003e\n        \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/1.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n             \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n    \u003ctable style=\"border-collapse: collapse;\n                  border: 0px;\n                  width: 100%;\n                  font-family: Arial;\n                  overflow-x: auto;\n                  background-color: #FFFFFF;\"\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"width: 100%;text-align: left;\n                       padding: 0px;\n                       font-size: 16px;\n                       border: 0;\n                       background-color: #FFFFFF;\"\u003e\n                \u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 1\" style=\"width: 100%;height: 100%;\"\u003e\n            \u003c\/td\u003e\n            \u003ctd style=\"width: 100%;text-align: left;\n                       padding: 0px;\n                       font-size: 16px;\n                       border: 0;\n                       background-color: #FFFFFF;\"\u003e\n                \u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 1\" style=\"width: 100%;height: 100%;\"\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/table\u003e\n\u003c\/div\u003e\n          \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e \n \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV00099\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eU.S. Solid\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e2 Wire Auto Return\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eUPVC\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e6 - 8 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eAC 85-265V\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e10 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e2 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1°C to 55°C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e50,000 to 80,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eFull\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\/G\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNormally Closed\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1°C to 50°C\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eIP65\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/CE.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP65 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYES. The motorized ball valve is made of lead-free UPVC.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n    \u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP65 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP65. The first digit 6 indicates complete dust - tightness. The second digit 5 means protection against water jets from any direction. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/valve%20model.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/JFMSV-User-manual.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n    \u003c\/div\u003e\n    \u003cdiv class=\"mobile-only\"\u003e\n        \u003c!--  --\u003e\n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; line-height:26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 0px; color: black; font-family: Arial;\"\u003eMotorized ball valves are a vital piece of equipment in numerous applications. This model opens and closes in 6-8 seconds, and remains in its new position while expending almost no energy. This is a key difference between motorized ball valves and many solenoid valves. Most solenoid valves are energized continuously when in a new position, while motorized ball valves expend energy only when changing from open to close, or vice versa.\u003cbr\u003eThe 2 wire auto return model is perfect for situations where the valve needs to be closed in case of power loss. The valve can be energized to open, and left hooked up, with negligible energy used once fully opened. To close, simply shutoff power to the valve. This valve is convenient because it can be operated with a simple on off switch. When on, it will remain open, when turned off (or power is lost for some other reason) the valve automatically closes.\u003c\/p\u003e\n            \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/1.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-bottom:10px; margin-top:20px; color: black;\"\u003e\u003cstrong\u003eAPPLICATION\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n    \u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 1\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n    \u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 1\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n\u003c\/div\u003e\n      \u003cp style=\"font-size: 16px; text-align: left; margin-bottom:10px; margin-top:20px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV00099\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eU.S. Solid\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e2 Wire Auto Return\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eUPVC\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e6 - 8 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eAC 85-265V\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e10 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e2 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1°C to 55°C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e50,000 to 80,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eFull\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\/G\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNormally Closed\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1°C to 50°C\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eIP65\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/CE.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP65 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYES. The motorized ball valve is made of lead-free UPVC.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n    \u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP65 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP65. The first digit 6 indicates complete dust - tightness. The second digit 5 means protection against water jets from any direction. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/valve%20model.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material-APP.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/JFMSV-User-manual.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n    \u003cscript\u003e\n\n        \/\/ (User Agent)\n        const isMobile = window.matchMedia(\"only screen and (max-width: 600px)\").matches;\n        const desktopContent = document.querySelector('.desktop-only');\n        const mobileContent = document.querySelector('.mobile-only');\n\n        if (isMobile) {\n            \/\/ \n            console.log('');\n            \/\/ ，\n            desktopContent.style.display = 'none';\n            mobileContent.style.display = 'block';\n        } else {\n            \/\/ \n            console.log('');            \n            \/\/ ，\n            desktopContent.style.display = 'block';\n            mobileContent.style.display = 'none';\n        }\n    \u003c\/script\u003e\n\n\n\n\u003c\/body\u003e","brand":"U.S. Solid","offers":[{"title":"NPT","offer_id":46918693028095,"sku":"JFMSV00099","price":48.49,"currency_code":"USD","in_stock":true},{"title":"G","offer_id":46918693060863,"sku":"JFMSV00099-G","price":45.49,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/1__76387.1729578916.1280.1280_128f6a80-5e1f-4c1a-a134-e7e9a2027b0c.jpg?v=1766544741"},{"product_id":"3-4-upvc-motorized-ball-valve-normally-open-9-36v-ac-dc-plastic-electrical-ball-valve-with-full-port-2-wire-auto-return-html","title":"3\/4\" UPVC Motorized Ball Valve - Normally Open 9-36V AC\/DC Plastic Electrical Ball Valve with Full Port, 2 Wire Auto Return","description":"\u003cbody\u003e \n\n\n    \u003cstyle\u003e\n        @media only screen and (max-width: 600px) {\n        }\n    \u003c\/style\u003e\n\n\n    \u003cdiv class=\"desktop-only\"\u003e\n       \n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; line-height: 26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 10px; color: black; font-family: Arial;\"\u003eMotorized ball valves are a vital piece of equipment in numerous applications. This model opens and closes in 6-8 seconds, and remains in its new position while expending almost no energy. This is a key difference between motorized ball valves and many solenoid valves. Most solenoid valves are energized continuously when in a new position, while motorized ball valves expend energy only when changing from open to close, or vice versa.\u003cbr\u003eThe 2 wire auto return model is perfect for situations where the valve needs to be closed in case of power loss. The valve can be energized to open, and left hooked up, with negligible energy used once fully opened. To close, simply shutoff power to the valve. This valve is convenient because it can be operated with a simple on off switch. When on, it will remain open, when turned off (or power is lost for some other reason) the valve automatically closes.\u003c\/p\u003e\n        \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/1.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n             \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n    \u003ctable style=\"border-collapse: collapse;\n                  border: 0px;\n                  width: 100%;\n                  font-family: Arial;\n                  overflow-x: auto;\n                  background-color: #FFFFFF;\"\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"width: 100%;text-align: left;\n                       padding: 0px;\n                       font-size: 16px;\n                       border: 0;\n                       background-color: #FFFFFF;\"\u003e\n                \u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 3\/4\" style=\"width: 100%;height: 100%;\"\u003e\n            \u003c\/td\u003e\n            \u003ctd style=\"width: 100%;text-align: left;\n                       padding: 0px;\n                       font-size: 16px;\n                       border: 0;\n                       background-color: #FFFFFF;\"\u003e\n                \u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 3\/4\" style=\"width: 100%;height: 100%;\"\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/table\u003e\n\u003c\/div\u003e\n          \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e \n \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV00095\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eU.S. Solid\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e3\/4\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e2 Wire Auto Return\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eUPVC\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e6 - 8 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e9-36V AC\/DC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e10 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e2 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1°C to 55°C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e50,000 to 80,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eFull\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\/G\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNormally Open\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1°C to 50°C\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eIP65\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/CE\/CE-EMC.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP65 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYES. The motorized ball valve is made of lead-free UPVC.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n    \u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP65 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP65. The first digit 6 indicates complete dust - tightness. The second digit 5 means protection against water jets from any direction. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/valve%20model.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/JFMSV-User-manual.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n    \u003c\/div\u003e\n    \u003cdiv class=\"mobile-only\"\u003e\n        \n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; line-height:26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 0px; color: black; font-family: Arial;\"\u003eMotorized ball valves are a vital piece of equipment in numerous applications. This model opens and closes in 6-8 seconds, and remains in its new position while expending almost no energy. This is a key difference between motorized ball valves and many solenoid valves. Most solenoid valves are energized continuously when in a new position, while motorized ball valves expend energy only when changing from open to close, or vice versa.\u003cbr\u003eThe 2 wire auto return model is perfect for situations where the valve needs to be closed in case of power loss. The valve can be energized to open, and left hooked up, with negligible energy used once fully opened. To close, simply shutoff power to the valve. This valve is convenient because it can be operated with a simple on off switch. When on, it will remain open, when turned off (or power is lost for some other reason) the valve automatically closes.\u003c\/p\u003e\n            \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/1.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-bottom:10px; margin-top:20px; color: black;\"\u003e\u003cstrong\u003eAPPLICATION\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n    \u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 3\/4\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n    \u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 3\/4\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n\u003c\/div\u003e\n      \u003cp style=\"font-size: 16px; text-align: left; margin-bottom:10px; margin-top:20px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV00095\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eU.S. Solid\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e3\/4\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e2 Wire Auto Return\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eUPVC\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e6 - 8 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e9-36V AC\/DC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e10 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e2 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1°C to 55°C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e50,000 to 80,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eFull\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\/G\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNormally Open\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1°C to 50°C\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eIP65\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/CE\/CE-EMC.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP65 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYES. The motorized ball valve is made of lead-free UPVC.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n    \u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP65 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP65. The first digit 6 indicates complete dust - tightness. The second digit 5 means protection against water jets from any direction. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/valve%20model.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material-APP.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/JFMSV-User-manual.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n    \u003cscript\u003e\n\n       \n        const isMobile = window.matchMedia(\"only screen and (max-width: 600px)\").matches;\n        const desktopContent = document.querySelector('.desktop-only');\n        const mobileContent = document.querySelector('.mobile-only');\n\n        if (isMobile) {\n      \n            console.log('');\n           \n            desktopContent.style.display = 'none';\n            mobileContent.style.display = 'block';\n        } else {\n            \n            console.log('');            \n            \n            desktopContent.style.display = 'block';\n            mobileContent.style.display = 'none';\n        }\n    \u003c\/script\u003e\n\n\n\n\u003c\/body\u003e","brand":"U.S. Solid","offers":[{"title":"NPT","offer_id":46918686081279,"sku":"JFMSV00095","price":35.29,"currency_code":"USD","in_stock":true},{"title":"G","offer_id":46918686114047,"sku":"JFMSV00095-G","price":35.19,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/1__38110.1729580791.1280.1280.jpg?v=1731291609"},{"product_id":"1-2-upvc-motorized-ball-valve-9-36v-ac-dc-plastic-electrical-ball-valve-with-standard-port-2-wire-auto-return-normally-closed-html","title":"1\/2\" UPVC Motorized Ball Valve - 9-24V AC\/DC Plastic Electrical Ball Valve with Standard Port, 2 Wire Auto Return, Normally Closed","description":"\u003cbody\u003e \n\n\n    \u003cstyle\u003e\n        @media only screen and (max-width: 600px) {\n        }\n    \u003c\/style\u003e\n\n\n    \u003cdiv class=\"desktop-only\"\u003e\n        \n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; line-height: 26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 10px; color: black; font-family: Arial;\"\u003eMotorized ball valves are a vital piece of equipment in numerous applications. This model opens and closes in 6-8 seconds, and remains in its new position while expending almost no energy. This is a key difference between motorized ball valves and many solenoid valves. Most solenoid valves are energized continuously when in a new position, while motorized ball valves expend energy only when changing from open to close, or vice versa.\u003cbr\u003eThe 2 wire auto return model is perfect for situations where the valve needs to be closed in case of power loss. The valve can be energized to open, and left hooked up, with negligible energy used once fully opened. To close, simply shutoff power to the valve. This valve is convenient because it can be operated with a simple on off switch. When on, it will remain open, when turned off (or power is lost for some other reason) the valve automatically closes.\u003c\/p\u003e\n        \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/1.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n             \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n    \u003ctable style=\"border-collapse: collapse;\n                  border: 0px;\n                  width: 100%;\n                  font-family: Arial;\n                  overflow-x: auto;\n                  background-color: #FFFFFF;\"\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"width: 100%;text-align: left;\n                       padding: 0px;\n                       font-size: 16px;\n                       border: 0;\n                       background-color: #FFFFFF;\"\u003e\n                \u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 1\/2\" style=\"width: 100%;height: 100%;\"\u003e\n            \u003c\/td\u003e\n            \u003ctd style=\"width: 100%;text-align: left;\n                       padding: 0px;\n                       font-size: 16px;\n                       border: 0;\n                       background-color: #FFFFFF;\"\u003e\n                \u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 1\/2\" style=\"width: 100%;height: 100%;\"\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/table\u003e\n\u003c\/div\u003e\n          \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e \n \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV00411\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eU.S. Solid\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1\/2\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e2 Wire Auto Return\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eUPVC\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e6 - 8 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e9-24V AC\/DC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e5 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e6 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e0°C to 60°C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e80,000 to 100,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eStandard\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\/G\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNormally Closed\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e-10°C to 40°C\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eIP65\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/CE\/CE-EMC.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP65 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYES. The motorized ball valve is made of lead-free Polyvinyl Chloride and is NSF certified.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n    \u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP65 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP65. The first digit 6 indicates complete dust - tightness. The second digit 5 means protection against water jets from any direction. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/valve%20model.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/JFMSV-User-manual.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n    \u003c\/div\u003e\n    \u003cdiv class=\"mobile-only\"\u003e\n        \n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; line-height:26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 0px; color: black; font-family: Arial;\"\u003eMotorized ball valves are a vital piece of equipment in numerous applications. This model opens and closes in 6-8 seconds, and remains in its new position while expending almost no energy. This is a key difference between motorized ball valves and many solenoid valves. Most solenoid valves are energized continuously when in a new position, while motorized ball valves expend energy only when changing from open to close, or vice versa.\u003cbr\u003eThe 2 wire auto return model is perfect for situations where the valve needs to be closed in case of power loss. The valve can be energized to open, and left hooked up, with negligible energy used once fully opened. To close, simply shutoff power to the valve. This valve is convenient because it can be operated with a simple on off switch. When on, it will remain open, when turned off (or power is lost for some other reason) the valve automatically closes.\u003c\/p\u003e\n            \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/1.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-bottom:10px; margin-top:20px; color: black;\"\u003e\u003cstrong\u003eAPPLICATION\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n    \u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 1\/2\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n    \u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 1\/2\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n\u003c\/div\u003e\n      \u003cp style=\"font-size: 16px; text-align: left; margin-bottom:10px; margin-top:20px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV00411\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eU.S. Solid\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1\/2\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e2 Wire Auto Return\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eUPVC\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e6 - 8 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e9-24V AC\/DC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e5 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e6 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e0°C to 60°C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e80,000 to 100,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eStandard\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\/G\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNormally Closed\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e-10°C to 40°C\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eIP65\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/CE\/CE-EMC.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP65 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYES. The motorized ball valve is made of lead-free Polyvinyl Chloride and is NSF certified.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n    \u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP65 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP65. The first digit 6 indicates complete dust - tightness. The second digit 5 means protection against water jets from any direction. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/valve%20model.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material-APP.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/JFMSV-User-manual.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n    \u003cscript\u003e\n\n       \n        const isMobile = window.matchMedia(\"only screen and (max-width: 600px)\").matches;\n        const desktopContent = document.querySelector('.desktop-only');\n        const mobileContent = document.querySelector('.mobile-only');\n\n        if (isMobile) {\n            \n            console.log('');\n            \n            desktopContent.style.display = 'none';\n            mobileContent.style.display = 'block';\n        } else {\n           \n            console.log('');            \n           \n            desktopContent.style.display = 'block';\n            mobileContent.style.display = 'none';\n        }\n    \u003c\/script\u003e\n\n\n\n\u003c\/body\u003e","brand":"U.S. Solid","offers":[{"title":"NPT","offer_id":46918682378495,"sku":"JFMSV00411","price":35.79,"currency_code":"USD","in_stock":true},{"title":"G","offer_id":46918682411263,"sku":"JFMSV00411-G","price":34.39,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/1__37287.1729564200.1280.1280.jpg?v=1731291624"},{"product_id":"1-upvc-motorized-ball-valve-110v-ac-plastic-electrical-ball-valve-with-standard-port-2-wire-auto-return-normally-closed-html","title":"1\" UPVC Motorized Ball Valve - 110\/220V AC Plastic Electrical Ball Valve with Standard Port, 2 Wire Auto Return, Normally Closed","description":"\u003cbody\u003e \n\n\n    \u003cstyle\u003e\n        @media only screen and (max-width: 600px) {\n        }\n    \u003c\/style\u003e\n\n\n    \u003cdiv class=\"desktop-only\"\u003e\n        \n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; line-height: 26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 10px; color: black; font-family: Arial;\"\u003eMotorized ball valves are a vital piece of equipment in numerous applications. This model Closes and closes in 6-8 seconds, and remains in its new position while expending almost no energy. This is a key difference between motorized ball valves and many solenoid valves. Most solenoid valves are energized continuously when in a new position, while motorized ball valves expend energy only when changing from Closed to close, or vice versa.\u003cbr\u003eThe 2 wire auto return model is perfect for situations where the valve needs to be Closed in case of power loss. The valve can be energized to Closed, and left hooked up, with negligible energy used once fully Closed. To close, simply shutoff power to the valve. This valve is convenient because it can be operated with a simple on off switch. When on, it will remain Closed, when turned off (or power is lost for some other reason) the valve automatically closes.\u003c\/p\u003e\n        \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/1.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n             \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n    \u003ctable style=\"border-collapse: collapse;\n                  border: 0px;\n                  width: 100%;\n                  font-family: Arial;\n                  overflow-x: auto;\n                  background-color: #FFFFFF;\"\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"width: 100%;text-align: left;\n                       padding: 0px;\n                       font-size: 16px;\n                       border: 0;\n                       background-color: #FFFFFF;\"\u003e\n                \u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 1\" style=\"width: 100%;height: 100%;\"\u003e\n            \u003c\/td\u003e\n            \u003ctd style=\"width: 100%;text-align: left;\n                       padding: 0px;\n                       font-size: 16px;\n                       border: 0;\n                       background-color: #FFFFFF;\"\u003e\n                \u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 1\" style=\"width: 100%;height: 100%;\"\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/table\u003e\n\u003c\/div\u003e\n          \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e \n \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV00419\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eU.S. Solid\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e2 Wire Auto Return\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eUPVC\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e6 - 8 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eAC 110V\/220V\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e5 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e6 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e0°C to 60°C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e80,000 to 100,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eStandard\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\/G\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNormally Closed\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e-10°C to 40°C\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eIP65\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/CE.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n       \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP65 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYES. The motorized ball valve is made of lead-free Polyvinyl Chloride and is NSF certified.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n    \u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                 \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP65 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP65. The first digit 6 indicates complete dust - tightness. The second digit 5 means protection against water jets from any direction. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e\n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/valve%20model.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/JFMSV-User-manual.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n    \u003c\/div\u003e\n    \u003cdiv class=\"mobile-only\"\u003e\n       \n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; line-height:26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 0px; color: black; font-family: Arial;\"\u003eMotorized ball valves are a vital piece of equipment in numerous applications. This model Closes and closes in 6-8 seconds, and remains in its new position while expending almost no energy. This is a key difference between motorized ball valves and many solenoid valves. Most solenoid valves are energized continuously when in a new position, while motorized ball valves expend energy only when changing from Closed to close, or vice versa.\u003cbr\u003eThe 2 wire auto return model is perfect for situations where the valve needs to be Closed in case of power loss. The valve can be energized to Closed, and left hooked up, with negligible energy used once fully Closed. To close, simply shutoff power to the valve. This valve is convenient because it can be operated with a simple on off switch. When on, it will remain Closed, when turned off (or power is lost for some other reason) the valve automatically closes.\u003c\/p\u003e\n            \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/1.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-bottom:10px; margin-top:20px; color: black;\"\u003e\u003cstrong\u003eAPPLICATION\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n    \u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 1\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n    \u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 1\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n\u003c\/div\u003e\n      \u003cp style=\"font-size: 16px; text-align: left; margin-bottom:10px; margin-top:20px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV00419\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eU.S. Solid\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e2 Wire Auto Return\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eUPVC\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e6 - 8 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eAC 110V\/220V\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e5 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e6 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e0°C to 60°C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e80,000 to 100,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eStandard\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\/G\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNormally Closed\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e-10°C to 40°C\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eIP65\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/CE.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n       \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP65 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYES. The motorized ball valve is made of lead-free Polyvinyl Chloride and is NSF certified.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n    \u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                 \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP65 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP65. The first digit 6 indicates complete dust - tightness. The second digit 5 means protection against water jets from any direction. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/valve%20model.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material-APP.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/JFMSV-User-manual.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n    \u003cscript\u003e\n\n        \n        const isMobile = window.matchMedia(\"only screen and (max-width: 600px)\").matches;\n        const desktopContent = document.querySelector('.desktop-only');\n        const mobileContent = document.querySelector('.mobile-only');\n\n        if (isMobile) {\n          \n            console.log('');\n            \n            desktopContent.style.display = 'none';\n            mobileContent.style.display = 'block';\n        } else {\n            \n            console.log('');            \n           \n            desktopContent.style.display = 'block';\n            mobileContent.style.display = 'none';\n        }\n    \u003c\/script\u003e\n\n\n\n\u003c\/body\u003e","brand":"U.S. Solid","offers":[{"title":"110V AC \/ NPT","offer_id":46918681624831,"sku":"JFMSV00419","price":55.15,"currency_code":"USD","in_stock":true},{"title":"220V AC \/ G","offer_id":46918681657599,"sku":"JFMSV00419-G","price":50.45,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/1__41511.1729567757.1280.1280.jpg?v=1731291624"},{"product_id":"1-2-upvc-motorized-ball-valve-9-36v-ac-dc-plastic-electrical-ball-valve-with-standard-port-2-wire-auto-return-normally-open-html","title":"1\/2\" UPVC Motorized Ball Valve - 9-24V AC\/DC Plastic Electrical Ball Valve with Standard Port, 2 Wire Auto Return, Normally Open","description":"\u003cbody\u003e \n\n\n    \u003cstyle\u003e\n        @media only screen and (max-width: 600px) {\n        }\n    \u003c\/style\u003e\n\n\n    \u003cdiv class=\"desktop-only\"\u003e\n        \n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; line-height: 26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 10px; color: black; font-family: Arial;\"\u003eMotorized ball valves are a vital piece of equipment in numerous applications. This model opens and closes in 6-8 seconds, and remains in its new position while expending almost no energy. This is a key difference between motorized ball valves and many solenoid valves. Most solenoid valves are energized continuously when in a new position, while motorized ball valves expend energy only when changing from open to close, or vice versa.\u003cbr\u003eThe 2 wire auto return model is perfect for situations where the valve needs to be Open in case of power loss. The valve can be energized to open, and left hooked up, with negligible energy used once fully opened. To close, simply shutoff power to the valve. This valve is convenient because it can be operated with a simple on off switch. When on, it will remain open, when turned off (or power is lost for some other reason) the valve automatically closes.\u003c\/p\u003e\n        \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/1.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n             \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n    \u003ctable style=\"border-collapse: collapse;\n                  border: 0px;\n                  width: 100%;\n                  font-family: Arial;\n                  overflow-x: auto;\n                  background-color: #FFFFFF;\"\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"width: 100%;text-align: left;\n                       padding: 0px;\n                       font-size: 16px;\n                       border: 0;\n                       background-color: #FFFFFF;\"\u003e\n                \u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 1\/2\" style=\"width: 100%;height: 100%;\"\u003e\n            \u003c\/td\u003e\n            \u003ctd style=\"width: 100%;text-align: left;\n                       padding: 0px;\n                       font-size: 16px;\n                       border: 0;\n                       background-color: #FFFFFF;\"\u003e\n                \u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 1\/2\" style=\"width: 100%;height: 100%;\"\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/table\u003e\n\u003c\/div\u003e\n          \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e \n \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV00414\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eU.S. Solid\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1\/2\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e2 Wire Auto Return\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eUPVC\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e6 - 8 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e9-24V AC\/DC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e5 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e6 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e0°C to 60°C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e80,000 to 100,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eStandard\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\/G\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNormally Open\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e-10°C to 40°C\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eIP65\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/CE\/CE-EMC.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n       \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP65 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYES. The motorized ball valve is made of lead-free Polyvinyl Chloride and is NSF certified.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n    \u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                 \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP65 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP65. The first digit 6 indicates complete dust - tightness. The second digit 5 means protection against water jets from any direction. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/valve%20model.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/JFMSV-User-manual.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n    \u003c\/div\u003e\n    \u003cdiv class=\"mobile-only\"\u003e\n        \n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; line-height:26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 0px; color: black; font-family: Arial;\"\u003eMotorized ball valves are a vital piece of equipment in numerous applications. This model opens and closes in 6-8 seconds, and remains in its new position while expending almost no energy. This is a key difference between motorized ball valves and many solenoid valves. Most solenoid valves are energized continuously when in a new position, while motorized ball valves expend energy only when changing from open to close, or vice versa.\u003cbr\u003eThe 2 wire auto return model is perfect for situations where the valve needs to be Open in case of power loss. The valve can be energized to open, and left hooked up, with negligible energy used once fully opened. To close, simply shutoff power to the valve. This valve is convenient because it can be operated with a simple on off switch. When on, it will remain open, when turned off (or power is lost for some other reason) the valve automatically closes.\u003c\/p\u003e\n            \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/1.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-bottom:10px; margin-top:20px; color: black;\"\u003e\u003cstrong\u003eAPPLICATION\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n    \u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 1\/2\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n    \u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 1\/2\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n\u003c\/div\u003e\n      \u003cp style=\"font-size: 16px; text-align: left; margin-bottom:10px; margin-top:20px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV00414\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eU.S. Solid\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1\/2\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e2 Wire Auto Return\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eUPVC\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e6 - 8 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e9-24V AC\/DC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e5 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e6 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e0°C to 60°C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e80,000 to 100,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eStandard\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\/G\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNormally Open\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e-10°C to 40°C\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eIP65\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/CE\/CE-EMC.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n       \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP65 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYES. The motorized ball valve is made of lead-free Polyvinyl Chloride and is NSF certified.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n    \u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                 \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP65 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP65. The first digit 6 indicates complete dust - tightness. The second digit 5 means protection against water jets from any direction. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/valve%20model.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material-APP.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/JFMSV-User-manual.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n    \u003cscript\u003e\n\n        \n        const isMobile = window.matchMedia(\"only screen and (max-width: 600px)\").matches;\n        const desktopContent = document.querySelector('.desktop-only');\n        const mobileContent = document.querySelector('.mobile-only');\n\n        if (isMobile) {\n            \n            console.log('');\n            \n            desktopContent.style.display = 'none';\n            mobileContent.style.display = 'block';\n        } else {\n            \n            console.log('');            \n            \n            desktopContent.style.display = 'block';\n            mobileContent.style.display = 'none';\n        }\n    \u003c\/script\u003e\n\n\n\n\u003c\/body\u003e","brand":"U.S. Solid","offers":[{"title":"NPT","offer_id":46918679920895,"sku":"JFMSV00414","price":36.19,"currency_code":"USD","in_stock":true},{"title":"G","offer_id":46918679953663,"sku":"JFMSV00414-G","price":34.39,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/1__97066.1729565864.1280.1280.jpg?v=1731291626"},{"product_id":"3-4-upvc-motorized-ball-valve-9-36v-ac-dc-plastic-electrical-ball-valve-with-standard-port-2-wire-auto-return-normally-open-html","title":"3\/4\" UPVC Motorized Ball Valve - 9-24V AC\/DC Plastic Electrical Ball Valve with Standard Port, 2 Wire Auto Return, Normally Open","description":"\u003cbody\u003e \n\n\n    \u003cstyle\u003e\n        @media only screen and (max-width: 600px) {\n        }\n    \u003c\/style\u003e\n\n\n    \u003cdiv class=\"desktop-only\"\u003e\n        \n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; line-height: 26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 10px; color: black; font-family: Arial;\"\u003eMotorized ball valves are a vital piece of equipment in numerous applications. This model opens and closes in 6-8 seconds, and remains in its new position while expending almost no energy. This is a key difference between motorized ball valves and many solenoid valves. Most solenoid valves are energized continuously when in a new position, while motorized ball valves expend energy only when changing from open to close, or vice versa.\u003cbr\u003eThe 2 wire auto return model is perfect for situations where the valve needs to be Open in case of power loss. The valve can be energized to open, and left hooked up, with negligible energy used once fully opened. To close, simply shutoff power to the valve. This valve is convenient because it can be operated with a simple on off switch. When on, it will remain open, when turned off (or power is lost for some other reason) the valve automatically closes.\u003c\/p\u003e\n        \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/1.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n             \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n    \u003ctable style=\"border-collapse: collapse;\n                  border: 0px;\n                  width: 100%;\n                  font-family: Arial;\n                  overflow-x: auto;\n                  background-color: #FFFFFF;\"\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"width: 100%;text-align: left;\n                       padding: 0px;\n                       font-size: 16px;\n                       border: 0;\n                       background-color: #FFFFFF;\"\u003e\n                \u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 3\/4\" style=\"width: 100%;height: 100%;\"\u003e\n            \u003c\/td\u003e\n            \u003ctd style=\"width: 100%;text-align: left;\n                       padding: 0px;\n                       font-size: 16px;\n                       border: 0;\n                       background-color: #FFFFFF;\"\u003e\n                \u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 3\/4\" style=\"width: 100%;height: 100%;\"\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/table\u003e\n\u003c\/div\u003e\n          \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e \n \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV00415\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eU.S. Solid\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e3\/4\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e2 Wire Auto Return\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eUPVC\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e6 - 8 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e9-24V AC\/DC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e5 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e6 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e0°C to 60°C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e80,000 to 100,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eStandard\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\/G\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNormally Open\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e-10°C to 40°C\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eIP65\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/CE\/CE-EMC.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n       \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP65 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYES. The motorized ball valve is made of lead-free Polyvinyl Chloride and is NSF certified.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n    \u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                 \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP65 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP65. The first digit 6 indicates complete dust - tightness. The second digit 5 means protection against water jets from any direction. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/valve%20model.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/JFMSV-User-manual.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n    \u003c\/div\u003e\n    \u003cdiv class=\"mobile-only\"\u003e\n      \n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; line-height:26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 0px; color: black; font-family: Arial;\"\u003eMotorized ball valves are a vital piece of equipment in numerous applications. This model opens and closes in 6-8 seconds, and remains in its new position while expending almost no energy. This is a key difference between motorized ball valves and many solenoid valves. Most solenoid valves are energized continuously when in a new position, while motorized ball valves expend energy only when changing from open to close, or vice versa.\u003cbr\u003eThe 2 wire auto return model is perfect for situations where the valve needs to be Open in case of power loss. The valve can be energized to open, and left hooked up, with negligible energy used once fully opened. To close, simply shutoff power to the valve. This valve is convenient because it can be operated with a simple on off switch. When on, it will remain open, when turned off (or power is lost for some other reason) the valve automatically closes.\u003c\/p\u003e\n            \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/1.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-bottom:10px; margin-top:20px; color: black;\"\u003e\u003cstrong\u003eAPPLICATION\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n    \u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 3\/4\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n    \u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 3\/4\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n\u003c\/div\u003e\n      \u003cp style=\"font-size: 16px; text-align: left; margin-bottom:10px; margin-top:20px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV00415\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eU.S. Solid\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e3\/4\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e2 Wire Auto Return\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eUPVC\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e6 - 8 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e9-24V AC\/DC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e5 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e6 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e0°C to 60°C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e80,000 to 100,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eStandard\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\/G\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNormally Open\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e-10°C to 40°C\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eIP65\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/CE\/CE-EMC.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n       \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP65 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYES. The motorized ball valve is made of lead-free Polyvinyl Chloride and is NSF certified.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n    \u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                 \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP65 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP65. The first digit 6 indicates complete dust - tightness. The second digit 5 means protection against water jets from any direction. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/valve%20model.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material-APP.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/JFMSV-User-manual.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n    \u003cscript\u003e\n\n        \n        const isMobile = window.matchMedia(\"only screen and (max-width: 600px)\").matches;\n        const desktopContent = document.querySelector('.desktop-only');\n        const mobileContent = document.querySelector('.mobile-only');\n\n        if (isMobile) {\n            \n            console.log('');\n           \n            desktopContent.style.display = 'none';\n            mobileContent.style.display = 'block';\n        } else {\n          \n            console.log('');            \n            \n            desktopContent.style.display = 'block';\n            mobileContent.style.display = 'none';\n        }\n    \u003c\/script\u003e\n\n\n\n\u003c\/body\u003e","brand":"U.S. Solid","offers":[{"title":"NPT","offer_id":46918676218111,"sku":"JFMSV00415","price":38.17,"currency_code":"USD","in_stock":true},{"title":"G","offer_id":46918676250879,"sku":"JFMSV00415-G","price":36.27,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/2__07057.1729566244.1280.1280.jpg?v=1731291624"},{"product_id":"1-2-upvc-motorized-ball-valve-110v-ac-plastic-electrical-ball-valve-with-standard-port-2-wire-auto-return-normally-closed-html","title":"1\/2\" UPVC Motorized Ball Valve - 110\/220V AC Plastic Electrical Ball Valve with Standard Port, 2 Wire Auto Return, Normally Closed","description":"\u003cbody\u003e \n\n\n    \u003cstyle\u003e\n        @media only screen and (max-width: 600px) {\n        }\n    \u003c\/style\u003e\n\n\n    \u003cdiv class=\"desktop-only\"\u003e\n        \n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; line-height: 26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 10px; color: black; font-family: Arial;\"\u003eMotorized ball valves are a vital piece of equipment in numerous applications. This model Closes and closes in 6-8 seconds, and remains in its new position while expending almost no energy. This is a key difference between motorized ball valves and many solenoid valves. Most solenoid valves are energized continuously when in a new position, while motorized ball valves expend energy only when changing from Closed to close, or vice versa.\u003cbr\u003eThe 2 wire auto return model is perfect for situations where the valve needs to be Closed in case of power loss. The valve can be energized to Closed, and left hooked up, with negligible energy used once fully Closed. To close, simply shutoff power to the valve. This valve is convenient because it can be operated with a simple on off switch. When on, it will remain Closed, when turned off (or power is lost for some other reason) the valve automatically closes.\u003c\/p\u003e\n        \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/1.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n             \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n    \u003ctable style=\"border-collapse: collapse;\n                  border: 0px;\n                  width: 100%;\n                  font-family: Arial;\n                  overflow-x: auto;\n                  background-color: #FFFFFF;\"\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"width: 100%;text-align: left;\n                       padding: 0px;\n                       font-size: 16px;\n                       border: 0;\n                       background-color: #FFFFFF;\"\u003e\n                \u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 1\/2\" style=\"width: 100%;height: 100%;\"\u003e\n            \u003c\/td\u003e\n            \u003ctd style=\"width: 100%;text-align: left;\n                       padding: 0px;\n                       font-size: 16px;\n                       border: 0;\n                       background-color: #FFFFFF;\"\u003e\n                \u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 1\/2\" style=\"width: 100%;height: 100%;\"\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/table\u003e\n\u003c\/div\u003e\n          \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e \n \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV00417\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eU.S. Solid\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1\/2\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e2 Wire Auto Return\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eUPVC\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e6 - 8 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eAC 110V\/220V\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e5 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e6 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e0°C to 60°C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e80,000 to 100,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eStandard\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\/G\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNormally Closed\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e-10°C to 40°C\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eIP65\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/CE.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n       \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP65 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYES. The motorized ball valve is made of lead-free Polyvinyl Chloride and is NSF certified.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n    \u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                 \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP65 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP65. The first digit 6 indicates complete dust - tightness. The second digit 5 means protection against water jets from any direction. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/valve%20model.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/JFMSV-User-manual.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n    \u003c\/div\u003e\n    \u003cdiv class=\"mobile-only\"\u003e\n        \n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; line-height:26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 0px; color: black; font-family: Arial;\"\u003eMotorized ball valves are a vital piece of equipment in numerous applications. This model Closes and closes in 6-8 seconds, and remains in its new position while expending almost no energy. This is a key difference between motorized ball valves and many solenoid valves. Most solenoid valves are energized continuously when in a new position, while motorized ball valves expend energy only when changing from Closed to close, or vice versa.\u003cbr\u003eThe 2 wire auto return model is perfect for situations where the valve needs to be Closed in case of power loss. The valve can be energized to Closed, and left hooked up, with negligible energy used once fully Closed. To close, simply shutoff power to the valve. This valve is convenient because it can be operated with a simple on off switch. When on, it will remain Closed, when turned off (or power is lost for some other reason) the valve automatically closes.\u003c\/p\u003e\n            \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/1.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-bottom:10px; margin-top:20px; color: black;\"\u003e\u003cstrong\u003eAPPLICATION\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n    \u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 1\/2\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n    \u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 1\/2\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n\u003c\/div\u003e\n      \u003cp style=\"font-size: 16px; text-align: left; margin-bottom:10px; margin-top:20px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV00417\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eU.S. Solid\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1\/2\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e2 Wire Auto Return\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eUPVC\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e6 - 8 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eAC 110V\/220V\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e5 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e6 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e0°C to 60°C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e80,000 to 100,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eStandard\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\/G\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNormally Closed\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e-10°C to 40°C\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eIP65\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/CE.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n       \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP65 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYES. The motorized ball valve is made of lead-free Polyvinyl Chloride and is NSF certified.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n    \u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                 \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP65 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP65. The first digit 6 indicates complete dust - tightness. The second digit 5 means protection against water jets from any direction. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/valve%20model.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material-APP.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/JFMSV-User-manual.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n    \u003cscript\u003e\n\n       \n        const isMobile = window.matchMedia(\"only screen and (max-width: 600px)\").matches;\n        const desktopContent = document.querySelector('.desktop-only');\n        const mobileContent = document.querySelector('.mobile-only');\n\n        if (isMobile) {\n           \n            console.log('');\n            \n            desktopContent.style.display = 'none';\n            mobileContent.style.display = 'block';\n        } else {\n            \n            console.log('');            \n            \n            desktopContent.style.display = 'block';\n            mobileContent.style.display = 'none';\n        }\n    \u003c\/script\u003e\n\n\n\n\u003c\/body\u003e","brand":"U.S. Solid","offers":[{"title":"110V AC \/ NPT","offer_id":46918674579711,"sku":"JFMSV00417","price":43.97,"currency_code":"USD","in_stock":true},{"title":"220V AC \/ G","offer_id":46918674612479,"sku":"JFMSV00417-G","price":41.97,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/1__67700.1729567146.1280.1280.jpg?v=1731291624"},{"product_id":"1-upvc-motorized-ball-valve-9-36v-ac-dc-plastic-electrical-ball-valve-with-standard-port-2-wire-auto-return-normally-open-html","title":"1\" UPVC Motorized Ball Valve - 9-24V AC\/DC Plastic Electrical Ball Valve with Standard Port, 2 Wire Auto Return, Normally Open","description":"\u003cbody\u003e \n\n\n    \u003cstyle\u003e\n        @media only screen and (max-width: 600px) {\n        }\n    \u003c\/style\u003e\n\n\n    \u003cdiv class=\"desktop-only\"\u003e\n        \n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; line-height: 26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 10px; color: black; font-family: Arial;\"\u003eMotorized ball valves are a vital piece of equipment in numerous applications. This model opens and closes in 6-8 seconds, and remains in its new position while expending almost no energy. This is a key difference between motorized ball valves and many solenoid valves. Most solenoid valves are energized continuously when in a new position, while motorized ball valves expend energy only when changing from open to close, or vice versa.\u003cbr\u003eThe 2 wire auto return model is perfect for situations where the valve needs to be Open in case of power loss. The valve can be energized to open, and left hooked up, with negligible energy used once fully opened. To close, simply shutoff power to the valve. This valve is convenient because it can be operated with a simple on off switch. When on, it will remain open, when turned off (or power is lost for some other reason) the valve automatically closes.\u003c\/p\u003e\n        \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/1.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n             \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n    \u003ctable style=\"border-collapse: collapse;\n                  border: 0px;\n                  width: 100%;\n                  font-family: Arial;\n                  overflow-x: auto;\n                  background-color: #FFFFFF;\"\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"width: 100%;text-align: left;\n                       padding: 0px;\n                       font-size: 16px;\n                       border: 0;\n                       background-color: #FFFFFF;\"\u003e\n                \u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 1\" style=\"width: 100%;height: 100%;\"\u003e\n            \u003c\/td\u003e\n            \u003ctd style=\"width: 100%;text-align: left;\n                       padding: 0px;\n                       font-size: 16px;\n                       border: 0;\n                       background-color: #FFFFFF;\"\u003e\n                \u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 1\" style=\"width: 100%;height: 100%;\"\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/table\u003e\n\u003c\/div\u003e\n          \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e \n \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV00416\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eU.S. Solid\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e2 Wire Auto Return\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eUPVC\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e6 - 8 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e9-24V AC\/DC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e5 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e6 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e0°C to 60°C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e80,000 to 100,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eStandard\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\/G\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNormally Open\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e-10°C to 40°C\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eIP65\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/CE\/CE-EMC.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n       \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP65 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYES. The motorized ball valve is made of lead-free Polyvinyl Chloride and is NSF certified.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n    \u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                 \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP65 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP65. The first digit 6 indicates complete dust - tightness. The second digit 5 means protection against water jets from any direction. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/valve%20model.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/JFMSV-User-manual.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n    \u003c\/div\u003e\n    \u003cdiv class=\"mobile-only\"\u003e\n        \n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; line-height:26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 0px; color: black; font-family: Arial;\"\u003eMotorized ball valves are a vital piece of equipment in numerous applications. This model opens and closes in 6-8 seconds, and remains in its new position while expending almost no energy. This is a key difference between motorized ball valves and many solenoid valves. Most solenoid valves are energized continuously when in a new position, while motorized ball valves expend energy only when changing from open to close, or vice versa.\u003cbr\u003eThe 2 wire auto return model is perfect for situations where the valve needs to be Open in case of power loss. The valve can be energized to open, and left hooked up, with negligible energy used once fully opened. To close, simply shutoff power to the valve. This valve is convenient because it can be operated with a simple on off switch. When on, it will remain open, when turned off (or power is lost for some other reason) the valve automatically closes.\u003c\/p\u003e\n            \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/1.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-bottom:10px; margin-top:20px; color: black;\"\u003e\u003cstrong\u003eAPPLICATION\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n    \u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 1\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n    \u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 1\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n\u003c\/div\u003e\n      \u003cp style=\"font-size: 16px; text-align: left; margin-bottom:10px; margin-top:20px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV00416\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eU.S. Solid\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e2 Wire Auto Return\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eUPVC\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e6 - 8 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e9-24V AC\/DC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e5 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e6 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e0°C to 60°C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e80,000 to 100,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eStandard\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\/G\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNormally Open\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e-10°C to 40°C\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eIP65\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/CE\/CE-EMC.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n       \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP65 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYES. The motorized ball valve is made of lead-free Polyvinyl Chloride and is NSF certified.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n    \u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                 \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP65 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP65. The first digit 6 indicates complete dust - tightness. The second digit 5 means protection against water jets from any direction. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/valve%20model.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material-APP.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/JFMSV-User-manual.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n    \u003cscript\u003e\n\n        \n        const isMobile = window.matchMedia(\"only screen and (max-width: 600px)\").matches;\n        const desktopContent = document.querySelector('.desktop-only');\n        const mobileContent = document.querySelector('.mobile-only');\n\n        if (isMobile) {\n            \n            console.log('');\n        \n            desktopContent.style.display = 'none';\n            mobileContent.style.display = 'block';\n        } else {\n            \n            console.log('');            \n            \n            desktopContent.style.display = 'block';\n            mobileContent.style.display = 'none';\n        }\n    \u003c\/script\u003e\n\n\n\n\u003c\/body\u003e","brand":"U.S. Solid","offers":[{"title":"NPT","offer_id":46918672843007,"sku":"JFMSV00416","price":47.37,"currency_code":"USD","in_stock":true},{"title":"G","offer_id":46918672875775,"sku":"JFMSV00416-G","price":41.97,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/3-2__11258.1729566925.1280.1280.jpg?v=1731291626"},{"product_id":"1-upvc-motorized-ball-valve-9-36v-ac-dc-plastic-electrical-ball-valve-with-standard-port-2-wire-auto-return-normally-closed-html","title":"1\" UPVC Motorized Ball Valve - 9-24V AC\/DC Plastic Electrical Ball Valve with Standard Port, 2 Wire Auto Return, Normally Closed","description":"\u003cbody\u003e \n\n\n    \u003cstyle\u003e\n        @media only screen and (max-width: 600px) {\n        }\n    \u003c\/style\u003e\n\n\n    \u003cdiv class=\"desktop-only\"\u003e\n        \n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; line-height: 26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 10px; color: black; font-family: Arial;\"\u003eMotorized ball valves are a vital piece of equipment in numerous applications. This model opens and closes in 6-8 seconds, and remains in its new position while expending almost no energy. This is a key difference between motorized ball valves and many solenoid valves. Most solenoid valves are energized continuously when in a new position, while motorized ball valves expend energy only when changing from open to close, or vice versa.\u003cbr\u003eThe 2 wire auto return model is perfect for situations where the valve needs to be closed in case of power loss. The valve can be energized to open, and left hooked up, with negligible energy used once fully opened. To close, simply shutoff power to the valve. This valve is convenient because it can be operated with a simple on off switch. When on, it will remain open, when turned off (or power is lost for some other reason) the valve automatically closes.\u003c\/p\u003e\n        \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/1.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n             \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n    \u003ctable style=\"border-collapse: collapse;\n                  border: 0px;\n                  width: 100%;\n                  font-family: Arial;\n                  overflow-x: auto;\n                  background-color: #FFFFFF;\"\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"width: 100%;text-align: left;\n                       padding: 0px;\n                       font-size: 16px;\n                       border: 0;\n                       background-color: #FFFFFF;\"\u003e\n                \u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 1\" style=\"width: 100%;height: 100%;\"\u003e\n            \u003c\/td\u003e\n            \u003ctd style=\"width: 100%;text-align: left;\n                       padding: 0px;\n                       font-size: 16px;\n                       border: 0;\n                       background-color: #FFFFFF;\"\u003e\n                \u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 1\" style=\"width: 100%;height: 100%;\"\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/table\u003e\n\u003c\/div\u003e\n          \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e \n \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV00413\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eU.S. Solid\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e2 Wire Auto Return\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eUPVC\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e6 - 8 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e9-24V AC\/DC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e5 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e6 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e0°C to 60°C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e80,000 to 100,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eStandard\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\/G\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNormally Closed\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e-10°C to 40°C\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eIP65\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/CE\/CE-EMC.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n       \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP65 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYES. The motorized ball valve is made of lead-free Polyvinyl Chloride and is NSF certified.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n    \u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                 \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP65 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP65. The first digit 6 indicates complete dust - tightness. The second digit 5 means protection against water jets from any direction. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/valve%20model.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/JFMSV-User-manual.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n    \u003c\/div\u003e\n    \u003cdiv class=\"mobile-only\"\u003e\n     \n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; line-height:26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 0px; color: black; font-family: Arial;\"\u003eMotorized ball valves are a vital piece of equipment in numerous applications. This model opens and closes in 6-8 seconds, and remains in its new position while expending almost no energy. This is a key difference between motorized ball valves and many solenoid valves. Most solenoid valves are energized continuously when in a new position, while motorized ball valves expend energy only when changing from open to close, or vice versa.\u003cbr\u003eThe 2 wire auto return model is perfect for situations where the valve needs to be closed in case of power loss. The valve can be energized to open, and left hooked up, with negligible energy used once fully opened. To close, simply shutoff power to the valve. This valve is convenient because it can be operated with a simple on off switch. When on, it will remain open, when turned off (or power is lost for some other reason) the valve automatically closes.\u003c\/p\u003e\n            \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/1.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-bottom:10px; margin-top:20px; color: black;\"\u003e\u003cstrong\u003eAPPLICATION\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n    \u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 1\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n    \u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 1\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n\u003c\/div\u003e\n      \u003cp style=\"font-size: 16px; text-align: left; margin-bottom:10px; margin-top:20px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV00413\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eU.S. Solid\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e2 Wire Auto Return\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eUPVC\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e6 - 8 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e9-24V AC\/DC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e5 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e6 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e0°C to 60°C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e80,000 to 100,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eStandard\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\/G\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNormally Closed\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e-10°C to 40°C\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eIP65\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/CE\/CE-EMC.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n       \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP65 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYES. The motorized ball valve is made of lead-free Polyvinyl Chloride and is NSF certified.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n    \u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                 \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP65 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP65. The first digit 6 indicates complete dust - tightness. The second digit 5 means protection against water jets from any direction. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/valve%20model.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material-APP.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/JFMSV-User-manual.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n    \u003cscript\u003e\n\n        \n        const isMobile = window.matchMedia(\"only screen and (max-width: 600px)\").matches;\n        const desktopContent = document.querySelector('.desktop-only');\n        const mobileContent = document.querySelector('.mobile-only');\n\n        if (isMobile) {\n            \n            console.log('');\n         \n            desktopContent.style.display = 'none';\n            mobileContent.style.display = 'block';\n        } else {\n            \n            console.log('');            \n           \n            desktopContent.style.display = 'block';\n            mobileContent.style.display = 'none';\n        }\n    \u003c\/script\u003e\n\n\n\n\u003c\/body\u003e","brand":"U.S. Solid","offers":[{"title":"NPT","offer_id":46918671204607,"sku":"JFMSV00413","price":42.07,"currency_code":"USD","in_stock":true},{"title":"G","offer_id":46918671237375,"sku":"JFMSV00413-G","price":41.97,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/2__59562.1729565368.1280.1280.jpg?v=1731291626"},{"product_id":"3-4-upvc-motorized-ball-valve-9-36v-ac-dc-plastic-electrical-ball-valve-with-standard-port-2-wire-auto-return-normally-closed-html","title":"3\/4\" UPVC Motorized Ball Valve - 9-24V AC\/DC Plastic Electrical Ball Valve with Standard Port, 2 Wire Auto Return, Normally Closed","description":"\u003cbody\u003e \n\n\n    \u003cstyle\u003e\n        @media only screen and (max-width: 600px) {\n        }\n    \u003c\/style\u003e\n\n\n    \u003cdiv class=\"desktop-only\"\u003e\n        \n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; line-height: 26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 10px; color: black; font-family: Arial;\"\u003eMotorized ball valves are a vital piece of equipment in numerous applications. This model opens and closes in 6-8 seconds, and remains in its new position while expending almost no energy. This is a key difference between motorized ball valves and many solenoid valves. Most solenoid valves are energized continuously when in a new position, while motorized ball valves expend energy only when changing from open to close, or vice versa.\u003cbr\u003eThe 2 wire auto return model is perfect for situations where the valve needs to be closed in case of power loss. The valve can be energized to open, and left hooked up, with negligible energy used once fully opened. To close, simply shutoff power to the valve. This valve is convenient because it can be operated with a simple on off switch. When on, it will remain open, when turned off (or power is lost for some other reason) the valve automatically closes.\u003c\/p\u003e\n        \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/1.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n             \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n    \u003ctable style=\"border-collapse: collapse;\n                  border: 0px;\n                  width: 100%;\n                  font-family: Arial;\n                  overflow-x: auto;\n                  background-color: #FFFFFF;\"\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"width: 100%;text-align: left;\n                       padding: 0px;\n                       font-size: 16px;\n                       border: 0;\n                       background-color: #FFFFFF;\"\u003e\n                \u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 3\/4\" style=\"width: 100%;height: 100%;\"\u003e\n            \u003c\/td\u003e\n            \u003ctd style=\"width: 100%;text-align: left;\n                       padding: 0px;\n                       font-size: 16px;\n                       border: 0;\n                       background-color: #FFFFFF;\"\u003e\n                \u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 3\/4\" style=\"width: 100%;height: 100%;\"\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/table\u003e\n\u003c\/div\u003e\n          \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e \n \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV00412\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eU.S. Solid\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e3\/4\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e2 Wire Auto Return\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eUPVC\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e6 - 8 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e9-24V AC\/DC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e5 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e6 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e0°C to 60°C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e80,000 to 100,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eStandard\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\/G\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNormally Closed\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e-10°C to 40°C\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eIP65\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/CE\/CE-EMC.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP65 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYES. The motorized ball valve is made of lead-free Polyvinyl Chloride and is NSF certified.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n    \u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP65 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP65. The first digit 6 indicates complete dust - tightness. The second digit 5 means protection against water jets from any direction. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/valve%20model.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/JFMSV-User-manual.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n    \u003c\/div\u003e\n    \u003cdiv class=\"mobile-only\"\u003e\n        \n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; line-height:26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 0px; color: black; font-family: Arial;\"\u003eMotorized ball valves are a vital piece of equipment in numerous applications. This model opens and closes in 6-8 seconds, and remains in its new position while expending almost no energy. This is a key difference between motorized ball valves and many solenoid valves. Most solenoid valves are energized continuously when in a new position, while motorized ball valves expend energy only when changing from open to close, or vice versa.\u003cbr\u003eThe 2 wire auto return model is perfect for situations where the valve needs to be closed in case of power loss. The valve can be energized to open, and left hooked up, with negligible energy used once fully opened. To close, simply shutoff power to the valve. This valve is convenient because it can be operated with a simple on off switch. When on, it will remain open, when turned off (or power is lost for some other reason) the valve automatically closes.\u003c\/p\u003e\n            \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/1.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-bottom:10px; margin-top:20px; color: black;\"\u003e\u003cstrong\u003eAPPLICATION\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n    \u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 3\/4\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n    \u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 3\/4\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n\u003c\/div\u003e\n      \u003cp style=\"font-size: 16px; text-align: left; margin-bottom:10px; margin-top:20px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV00412\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eU.S. Solid\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e3\/4\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e2 Wire Auto Return\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eUPVC\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e6 - 8 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e9-24V AC\/DC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e5 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e6 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e0°C to 60°C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e80,000 to 100,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eStandard\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\/G\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNormally Closed\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e-10°C to 40°C\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eIP65\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/CE\/CE-EMC.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP65 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYES. The motorized ball valve is made of lead-free Polyvinyl Chloride and is NSF certified.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n    \u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP65 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP65. The first digit 6 indicates complete dust - tightness. The second digit 5 means protection against water jets from any direction. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/valve%20model.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material-APP.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/JFMSV-User-manual.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n    \u003cscript\u003e\n\n        \n        const isMobile = window.matchMedia(\"only screen and (max-width: 600px)\").matches;\n        const desktopContent = document.querySelector('.desktop-only');\n        const mobileContent = document.querySelector('.mobile-only');\n\n        if (isMobile) {\n       \n            console.log('');\n            \n            desktopContent.style.display = 'none';\n            mobileContent.style.display = 'block';\n        } else {\n           \n            console.log('');            \n          \n            desktopContent.style.display = 'block';\n            mobileContent.style.display = 'none';\n        }\n    \u003c\/script\u003e\n\n\n\n\u003c\/body\u003e","brand":"U.S. Solid","offers":[{"title":"NPT","offer_id":46918668124415,"sku":"JFMSV00412","price":36.37,"currency_code":"USD","in_stock":true},{"title":"G","offer_id":46918668157183,"sku":"JFMSV00412-G","price":36.27,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/1__00390.1729564980.1280.1280.jpg?v=1731291627"},{"product_id":"3-4-upvc-motorized-ball-valve-110v-ac-plastic-electrical-ball-valve-with-standard-port-2-wire-auto-return-normally-closed-html","title":"3\/4\" UPVC Motorized Ball Valve - 110\/220V AC Plastic Electrical Ball Valve with Standard Port, 2 Wire Auto Return, Normally Closed","description":"\u003cbody\u003e \n\n\n    \u003cstyle\u003e\n        @media only screen and (max-width: 600px) {\n        }\n    \u003c\/style\u003e\n\n\n    \u003cdiv class=\"desktop-only\"\u003e\n        \n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; line-height: 26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 10px; color: black; font-family: Arial;\"\u003eMotorized ball valves are a vital piece of equipment in numerous applications. This model Closes and closes in 6-8 seconds, and remains in its new position while expending almost no energy. This is a key difference between motorized ball valves and many solenoid valves. Most solenoid valves are energized continuously when in a new position, while motorized ball valves expend energy only when changing from Closed to close, or vice versa.\u003cbr\u003eThe 2 wire auto return model is perfect for situations where the valve needs to be Closed in case of power loss. The valve can be energized to Closed, and left hooked up, with negligible energy used once fully Closed. To close, simply shutoff power to the valve. This valve is convenient because it can be operated with a simple on off switch. When on, it will remain Closed, when turned off (or power is lost for some other reason) the valve automatically closes.\u003c\/p\u003e\n        \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/1.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n             \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n    \u003ctable style=\"border-collapse: collapse;\n                  border: 0px;\n                  width: 100%;\n                  font-family: Arial;\n                  overflow-x: auto;\n                  background-color: #FFFFFF;\"\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"width: 100%;text-align: left;\n                       padding: 0px;\n                       font-size: 16px;\n                       border: 0;\n                       background-color: #FFFFFF;\"\u003e\n                \u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 3\/4\" style=\"width: 100%;height: 100%;\"\u003e\n            \u003c\/td\u003e\n            \u003ctd style=\"width: 100%;text-align: left;\n                       padding: 0px;\n                       font-size: 16px;\n                       border: 0;\n                       background-color: #FFFFFF;\"\u003e\n                \u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 3\/4\" style=\"width: 100%;height: 100%;\"\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/table\u003e\n\u003c\/div\u003e\n          \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e \n \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV00418\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eU.S. Solid\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e3\/4\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e2 Wire Auto Return\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eUPVC\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e6 - 8 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eAC 110V\/220V\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e5 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e6 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e0°C to 60°C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e80,000 to 100,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eStandard\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\/G\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNormally Closed\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e-10°C to 40°C\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eIP65\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/CE.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n       \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP65 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYES. The motorized ball valve is made of lead-free Polyvinyl Chloride and is NSF certified.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n    \u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                 \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP65 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP65. The first digit 6 indicates complete dust - tightness. The second digit 5 means protection against water jets from any direction. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e\n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/valve%20model.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/JFMSV-User-manual.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n    \u003c\/div\u003e\n    \u003cdiv class=\"mobile-only\"\u003e\n        \n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; line-height:26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 0px; color: black; font-family: Arial;\"\u003eMotorized ball valves are a vital piece of equipment in numerous applications. This model Closes and closes in 6-8 seconds, and remains in its new position while expending almost no energy. This is a key difference between motorized ball valves and many solenoid valves. Most solenoid valves are energized continuously when in a new position, while motorized ball valves expend energy only when changing from Closed to close, or vice versa.\u003cbr\u003eThe 2 wire auto return model is perfect for situations where the valve needs to be Closed in case of power loss. The valve can be energized to Closed, and left hooked up, with negligible energy used once fully Closed. To close, simply shutoff power to the valve. This valve is convenient because it can be operated with a simple on off switch. When on, it will remain Closed, when turned off (or power is lost for some other reason) the valve automatically closes.\u003c\/p\u003e\n            \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/1.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-bottom:10px; margin-top:20px; color: black;\"\u003e\u003cstrong\u003eAPPLICATION\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n    \u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 3\/4\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n    \u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 3\/4\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n\u003c\/div\u003e\n      \u003cp style=\"font-size: 16px; text-align: left; margin-bottom:10px; margin-top:20px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV00418\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eU.S. Solid\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e3\/4\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e2 Wire Auto Return\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eUPVC\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e6 - 8 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eAC 110V\/220V\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e5 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e6 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e0°C to 60°C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e80,000 to 100,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eStandard\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\/G\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNormally Closed\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e-10°C to 40°C\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eIP65\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/CE.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n       \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP65 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYES. The motorized ball valve is made of lead-free Polyvinyl Chloride and is NSF certified.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n    \u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                 \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP65 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP65. The first digit 6 indicates complete dust - tightness. The second digit 5 means protection against water jets from any direction. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/valve%20model.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material-APP.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/JFMSV-User-manual.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n    \u003cscript\u003e\n\n        \n        const isMobile = window.matchMedia(\"only screen and (max-width: 600px)\").matches;\n        const desktopContent = document.querySelector('.desktop-only');\n        const mobileContent = document.querySelector('.mobile-only');\n\n        if (isMobile) {\n           \n            console.log('');\n            \n            desktopContent.style.display = 'none';\n            mobileContent.style.display = 'block';\n        } else {\n           \n            console.log('');            \n           \n            desktopContent.style.display = 'block';\n            mobileContent.style.display = 'none';\n        }\n    \u003c\/script\u003e\n\n\n\n\u003c\/body\u003e","brand":"U.S. Solid","offers":[{"title":"110V AC \/ NPT","offer_id":46918665797887,"sku":"JFMSV00418","price":45.09,"currency_code":"USD","in_stock":true},{"title":"220V AC \/ G","offer_id":46918665830655,"sku":"JFMSV00418-G","price":44.99,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/1__90683.1729567530.1280.1280.jpg?v=1731291628"},{"product_id":"1-2-pvc-motorized-ball-valve-110-220v-ac-plastic-electric-ball-valve-auto-return-normally-closed","title":"1\/2\" PVC Motorized Ball Valve - 110\/220V AC Plastic Electric Ball Valve, Auto Return, Normally Closed","description":"\u003cbody\u003e \n\n\n    \u003cstyle\u003e\n        @media only screen and (max-width: 600px) {\n        }\n    \u003c\/style\u003e\n\n\n    \u003cdiv class=\"desktop-only\"\u003e\n     \n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; line-height: 26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 10px; color: black; font-family: Arial;\"\u003eMotorized ball valves present an energy-efficient substitute for solenoid valves, particularly when it comes to prolonged positioning. They primarily consume power during the processes of opening and closing, and the energy consumption is negligible once they are fully opened. This characteristic enables a permanent connection, eliminating the risks of overheating or burnout.\u003c\/p\u003e\n        \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/1.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n             \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n    \u003ctable style=\"border-collapse: collapse;\n                  border: 0px;\n                  width: 100%;\n                  font-family: Arial;\n                  overflow-x: auto;\n                  background-color: #FFFFFF;\"\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"width: 100%;text-align: left;\n                       padding: 0px;\n                       font-size: 16px;\n                       border: 0;\n                       background-color: #FFFFFF;\"\u003e\n                \u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 1\" style=\"width: 100%;height: 100%;\"\u003e\n            \u003c\/td\u003e\n            \u003ctd style=\"width: 100%;text-align: left;\n                       padding: 0px;\n                       font-size: 16px;\n                       border: 0;\n                       background-color: #FFFFFF;\"\u003e\n                \u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 2\" style=\"width: 100%;height: 100%;\"\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/table\u003e\n\u003c\/div\u003e\n          \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e \n \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV20013\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eU.S. Solid\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1\/2\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eUS Plug\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003ePPE\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e6 - 8 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eAC 110V\/220V\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e5 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e3 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e0℃-90 ℃\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e70,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eStandard\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\/G\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNormally Closed\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e-10℃- 40 ℃\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eIP67\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/CE.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP67 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYES. The motorized ball valve is made of PPE.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n    \u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP67 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP67. The first digit 6 indicates complete dust - tightness. The second digit 7 means protection from immersion(up to 1M) for a limited time. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/IP67-SS304.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/Manual%20for%20Tonhe.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n    \u003c\/div\u003e\n    \u003cdiv class=\"mobile-only\"\u003e\n        \n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; line-height:26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 0px; color: black; font-family: Arial;\"\u003eMotorized ball valves present an energy-efficient substitute for solenoid valves, particularly when it comes to prolonged positioning. They primarily consume power during the processes of opening and closing, and the energy consumption is negligible once they are fully opened. This characteristic enables a permanent connection, eliminating the risks of overheating or burnout.\u003c\/p\u003e\n            \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/1.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-bottom:10px; margin-top:20px; color: black;\"\u003e\u003cstrong\u003eAPPLICATION\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n    \u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 1\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n    \u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 2\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n\u003c\/div\u003e\n      \u003cp style=\"font-size: 16px; text-align: left; margin-bottom:10px; margin-top:20px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n       \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV20013\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eU.S. Solid\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1\/2\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eUS Plug\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003ePPE\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e6 - 8 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eAC 110V\/220V\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e5 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e3 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e0℃-90 ℃\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e70,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eStandard\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\/G\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNormally Closed\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e-10℃- 40 ℃\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eIP67\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/CE.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n       \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP67 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYES. The motorized ball valve is made of PPE.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n    \u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                 \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP67 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP67. The first digit 6 indicates complete dust - tightness. The second digit 7 means protection from immersion(up to 1M) for a limited time. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/IP67-SS304.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material-APP.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/Manual%20for%20Tonhe.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n    \u003cscript\u003e\n\n       \n        const isMobile = window.matchMedia(\"only screen and (max-width: 600px)\").matches;\n        const desktopContent = document.querySelector('.desktop-only');\n        const mobileContent = document.querySelector('.mobile-only');\n\n        if (isMobile) {\n           \n            console.log('');\n            \n            desktopContent.style.display = 'none';\n            mobileContent.style.display = 'block';\n        } else {\n       \n            console.log('');            \n           \n            desktopContent.style.display = 'block';\n            mobileContent.style.display = 'none';\n        }\n    \u003c\/script\u003e\n\n\n\n\u003c\/body\u003e","brand":"U.S. Solid","offers":[{"title":"110V AC \/ NPT","offer_id":47055981314303,"sku":"JFMSV20013","price":74.0,"currency_code":"USD","in_stock":true},{"title":"220V AC \/ G","offer_id":47055981347071,"sku":"JFMSV20013-G","price":74.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/3_7ee1b2b3-1249-4f5a-9924-2f31864a9fd8.png?v=1750400239"},{"product_id":"3-4-pvc-motorized-ball-valve-110-220v-ac-plastic-electric-ball-valve-auto-return-normally-closed","title":"3\/4\" PVC Motorized Ball Valve - 110\/220V AC Plastic Electric Ball Valve, Auto Return, Normally Closed","description":"\u003cbody\u003e \n\n\n    \u003cstyle\u003e\n        @media only screen and (max-width: 600px) {\n        }\n    \u003c\/style\u003e\n\n\n    \u003cdiv class=\"desktop-only\"\u003e\n     \n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; line-height: 26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 10px; color: black; font-family: Arial;\"\u003eMotorized ball valves present an energy-efficient substitute for solenoid valves, particularly when it comes to prolonged positioning. They primarily consume power during the processes of opening and closing, and the energy consumption is negligible once they are fully opened. This characteristic enables a permanent connection, eliminating the risks of overheating or burnout.\u003c\/p\u003e\n        \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/1.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n             \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n    \u003ctable style=\"border-collapse: collapse;\n                  border: 0px;\n                  width: 100%;\n                  font-family: Arial;\n                  overflow-x: auto;\n                  background-color: #FFFFFF;\"\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"width: 100%;text-align: left;\n                       padding: 0px;\n                       font-size: 16px;\n                       border: 0;\n                       background-color: #FFFFFF;\"\u003e\n                \u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 1\" style=\"width: 100%;height: 100%;\"\u003e\n            \u003c\/td\u003e\n            \u003ctd style=\"width: 100%;text-align: left;\n                       padding: 0px;\n                       font-size: 16px;\n                       border: 0;\n                       background-color: #FFFFFF;\"\u003e\n                \u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 2\" style=\"width: 100%;height: 100%;\"\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/table\u003e\n\u003c\/div\u003e\n          \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e \n \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV20014\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eU.S. Solid\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e3\/4\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eUS Plug\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003ePPE\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e6 - 8 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eAC 110V\/220V\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e5 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e3 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e0℃-90 ℃\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e70,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eStandard\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\/G\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNormally Closed\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e-10℃- 40 ℃\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eIP67\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/CE.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP67 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYES. The motorized ball valve is made of PPE.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n    \u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP67 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP67. The first digit 6 indicates complete dust - tightness. The second digit 7 means protection from immersion(up to 1M) for a limited time. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/IP67-SS304.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/Manual%20for%20Tonhe.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n    \u003c\/div\u003e\n    \u003cdiv class=\"mobile-only\"\u003e\n        \n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; line-height:26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 0px; color: black; font-family: Arial;\"\u003eMotorized ball valves present an energy-efficient substitute for solenoid valves, particularly when it comes to prolonged positioning. They primarily consume power during the processes of opening and closing, and the energy consumption is negligible once they are fully opened. This characteristic enables a permanent connection, eliminating the risks of overheating or burnout.\u003c\/p\u003e\n            \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/1.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-bottom:10px; margin-top:20px; color: black;\"\u003e\u003cstrong\u003eAPPLICATION\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n    \u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 1\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n    \u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 2\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n\u003c\/div\u003e\n      \u003cp style=\"font-size: 16px; text-align: left; margin-bottom:10px; margin-top:20px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n       \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV20014\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eU.S. Solid\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e3\/4\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eUS Plug\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003ePPE\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e6 - 8 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eAC 110V\/220V\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e5 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e3 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e0℃-90 ℃\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e70,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eStandard\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\/G\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNormally Closed\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e-10℃- 40 ℃\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eIP67\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/CE.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n       \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP67 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYES. The motorized ball valve is made of PPE.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n    \u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                 \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP67 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP67. The first digit 6 indicates complete dust - tightness. The second digit 7 means protection from immersion(up to 1M) for a limited time. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/IP67-SS304.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material-APP.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/Manual%20for%20Tonhe.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n    \u003cscript\u003e\n\n       \n        const isMobile = window.matchMedia(\"only screen and (max-width: 600px)\").matches;\n        const desktopContent = document.querySelector('.desktop-only');\n        const mobileContent = document.querySelector('.mobile-only');\n\n        if (isMobile) {\n           \n            console.log('');\n            \n            desktopContent.style.display = 'none';\n            mobileContent.style.display = 'block';\n        } else {\n       \n            console.log('');            \n           \n            desktopContent.style.display = 'block';\n            mobileContent.style.display = 'none';\n        }\n    \u003c\/script\u003e\n\n\n\n\u003c\/body\u003e","brand":"U.S. Solid","offers":[{"title":"110V AC \/ NPT","offer_id":47043370418431,"sku":"JFMSV20014","price":82.0,"currency_code":"USD","in_stock":true},{"title":"220V AC \/ G","offer_id":47043370451199,"sku":"JFMSV20014-G","price":84.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/3_d6990b8c-c28a-46a8-be53-45b2ca3cc2b0.png?v=1751534533"},{"product_id":"1-pvc-motorized-ball-valve-110-220v-ac-plastic-electric-ball-valve-auto-return-normally-closed","title":"1\" PVC Motorized Ball Valve - 110\/220V AC Plastic Electric Ball Valve, Auto Return, Normally Closed","description":"\u003cbody\u003e \n\n\n    \u003cstyle\u003e\n        @media only screen and (max-width: 600px) {\n        }\n    \u003c\/style\u003e\n\n\n    \u003cdiv class=\"desktop-only\"\u003e\n     \n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; line-height: 26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 10px; color: black; font-family: Arial;\"\u003eMotorized ball valves present an energy-efficient substitute for solenoid valves, particularly when it comes to prolonged positioning. They primarily consume power during the processes of opening and closing, and the energy consumption is negligible once they are fully opened. This characteristic enables a permanent connection, eliminating the risks of overheating or burnout.\u003c\/p\u003e\n        \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/1.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n             \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n    \u003ctable style=\"border-collapse: collapse;\n                  border: 0px;\n                  width: 100%;\n                  font-family: Arial;\n                  overflow-x: auto;\n                  background-color: #FFFFFF;\"\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"width: 100%;text-align: left;\n                       padding: 0px;\n                       font-size: 16px;\n                       border: 0;\n                       background-color: #FFFFFF;\"\u003e\n                \u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 1\" style=\"width: 100%;height: 100%;\"\u003e\n            \u003c\/td\u003e\n            \u003ctd style=\"width: 100%;text-align: left;\n                       padding: 0px;\n                       font-size: 16px;\n                       border: 0;\n                       background-color: #FFFFFF;\"\u003e\n                \u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 2\" style=\"width: 100%;height: 100%;\"\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/table\u003e\n\u003c\/div\u003e\n          \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e \n \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV20015\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eU.S. Solid\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eUS Plug\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003ePPE\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e6 - 8 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eAC 110V\/220V\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e5 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e3 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e0℃-90 ℃\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e70,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eStandard\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\/G\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNormally Closed\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e-10℃- 40 ℃\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eIP67\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/CE.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP67 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYES. The motorized ball valve is made of PPE.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n    \u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP67 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP67. The first digit 6 indicates complete dust - tightness. The second digit 7 means protection from immersion(up to 1M) for a limited time. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/IP67-SS304.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/Manual%20for%20Tonhe.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n    \u003c\/div\u003e\n    \u003cdiv class=\"mobile-only\"\u003e\n        \n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; line-height:26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 0px; color: black; font-family: Arial;\"\u003eMotorized ball valves present an energy-efficient substitute for solenoid valves, particularly when it comes to prolonged positioning. They primarily consume power during the processes of opening and closing, and the energy consumption is negligible once they are fully opened. This characteristic enables a permanent connection, eliminating the risks of overheating or burnout.\u003c\/p\u003e\n            \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/1.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-bottom:10px; margin-top:20px; color: black;\"\u003e\u003cstrong\u003eAPPLICATION\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n    \u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 1\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n    \u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 2\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n\u003c\/div\u003e\n      \u003cp style=\"font-size: 16px; text-align: left; margin-bottom:10px; margin-top:20px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n       \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV20015\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eU.S. Solid\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eUS Plug\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003ePPE\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e6 - 8 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eAC 110V\/220V\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e5 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e3 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e0℃-90 ℃\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e70,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eStandard\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\/G\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNormally Closed\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e-10℃- 40 ℃\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eIP67\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/CE.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n       \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP67 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYES. The motorized ball valve is made of PPE.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n    \u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                 \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP67 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP67. The first digit 6 indicates complete dust - tightness. The second digit 7 means protection from immersion(up to 1M) for a limited time. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/IP67-SS304.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material-APP.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/Manual%20for%20Tonhe.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n    \u003cscript\u003e\n\n       \n        const isMobile = window.matchMedia(\"only screen and (max-width: 600px)\").matches;\n        const desktopContent = document.querySelector('.desktop-only');\n        const mobileContent = document.querySelector('.mobile-only');\n\n        if (isMobile) {\n           \n            console.log('');\n            \n            desktopContent.style.display = 'none';\n            mobileContent.style.display = 'block';\n        } else {\n       \n            console.log('');            \n           \n            desktopContent.style.display = 'block';\n            mobileContent.style.display = 'none';\n        }\n    \u003c\/script\u003e\n\n\n\n\u003c\/body\u003e","brand":"U.S. Solid","offers":[{"title":"110V AC \/ NPT","offer_id":47055982133503,"sku":"JFMSV20015","price":106.0,"currency_code":"USD","in_stock":true},{"title":"220V AC \/ G","offer_id":47055982166271,"sku":"JFMSV20015-G","price":94.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/3_33aff181-7b53-4c7d-a2f5-9e72d870b606.png?v=1750400254"},{"product_id":"1-2-pvc-motorized-ball-valve-110v-ac-electric-ball-valve-auto-return-normally-closed","title":"1\/2\" PVC Motorized Ball Valve - 110\/220V AC Plastic Electric Ball Valve, Auto Return, Normally Closed","description":"\u003cbody\u003e \n\n\n    \u003cstyle\u003e\n        @media only screen and (max-width: 600px) {\n        }\n    \u003c\/style\u003e\n\n\n    \u003cdiv class=\"desktop-only\"\u003e\n     \n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; line-height: 26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 10px; color: black; font-family: Arial;\"\u003eMotorized ball valves present an energy-efficient substitute for solenoid valves, particularly when it comes to prolonged positioning. They primarily consume power during the processes of opening and closing, and the energy consumption is negligible once they are fully opened. This characteristic enables a permanent connection, eliminating the risks of overheating or burnout.\u003c\/p\u003e\n        \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/1.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n             \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n    \u003ctable style=\"border-collapse: collapse;\n                  border: 0px;\n                  width: 100%;\n                  font-family: Arial;\n                  overflow-x: auto;\n                  background-color: #FFFFFF;\"\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"width: 100%;text-align: left;\n                       padding: 0px;\n                       font-size: 16px;\n                       border: 0;\n                       background-color: #FFFFFF;\"\u003e\n                \u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 1\" style=\"width: 100%;height: 100%;\"\u003e\n            \u003c\/td\u003e\n            \u003ctd style=\"width: 100%;text-align: left;\n                       padding: 0px;\n                       font-size: 16px;\n                       border: 0;\n                       background-color: #FFFFFF;\"\u003e\n                \u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 2\" style=\"width: 100%;height: 100%;\"\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/table\u003e\n\u003c\/div\u003e\n          \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e \n \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV20016\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eU.S. Solid\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1\/2\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eUS Plug\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eUPVC\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e6 - 8 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eAC 110V\/220V\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e5 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e3 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e0℃-90 ℃\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e70,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eStandard\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\/G\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNormally Closed\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e-10℃- 40 ℃\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eIP67\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/CE.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP67 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYES. The motorized ball valve is made of UPVC.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n    \u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP67 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP67. The first digit 6 indicates complete dust - tightness. The second digit 7 means protection from immersion(up to 1M) for a limited time. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/IP67-SS304.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/Manual%20for%20Tonhe.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n    \u003c\/div\u003e\n    \u003cdiv class=\"mobile-only\"\u003e\n        \n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; line-height:26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 0px; color: black; font-family: Arial;\"\u003eMotorized ball valves present an energy-efficient substitute for solenoid valves, particularly when it comes to prolonged positioning. They primarily consume power during the processes of opening and closing, and the energy consumption is negligible once they are fully opened. This characteristic enables a permanent connection, eliminating the risks of overheating or burnout.\u003c\/p\u003e\n            \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/1.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-bottom:10px; margin-top:20px; color: black;\"\u003e\u003cstrong\u003eAPPLICATION\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n    \u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 1\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n    \u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 2\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n\u003c\/div\u003e\n      \u003cp style=\"font-size: 16px; text-align: left; margin-bottom:10px; margin-top:20px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n       \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV20016\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eU.S. Solid\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1\/2\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eUS Plug\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eUPVC\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e6 - 8 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eAC 110V\/220V\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e5 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e3 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e0℃-90 ℃\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e70,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eStandard\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\/G\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNormally Closed\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e-10℃- 40 ℃\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eIP67\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/CE.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n       \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP67 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYES. The motorized ball valve is made of UPVC.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n    \u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                 \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP67 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP67. The first digit 6 indicates complete dust - tightness. The second digit 7 means protection from immersion(up to 1M) for a limited time. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/IP67-SS304.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material-APP.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/Manual%20for%20Tonhe.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n    \u003cscript\u003e\n\n       \n        const isMobile = window.matchMedia(\"only screen and (max-width: 600px)\").matches;\n        const desktopContent = document.querySelector('.desktop-only');\n        const mobileContent = document.querySelector('.mobile-only');\n\n        if (isMobile) {\n           \n            console.log('');\n            \n            desktopContent.style.display = 'none';\n            mobileContent.style.display = 'block';\n        } else {\n       \n            console.log('');            \n           \n            desktopContent.style.display = 'block';\n            mobileContent.style.display = 'none';\n        }\n    \u003c\/script\u003e\n\n\n\n\u003c\/body\u003e","brand":"U.S. Solid","offers":[{"title":"110V AC \/ NPT","offer_id":47043371106559,"sku":"JFMSV20016","price":99.0,"currency_code":"USD","in_stock":true},{"title":"220V AC \/ G","offer_id":47043371139327,"sku":"JFMSV20016-G","price":74.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/7_aeabf986-ef9b-48f0-85e1-fa1d351d574e.png?v=1752720042"},{"product_id":"3-4-pvc-motorized-ball-valve-110v-ac-electric-ball-valve-auto-return-normally-closed","title":"3\/4\" PVC Motorized Ball Valve - 110\/220V AC Plastic Electric Ball Valve, Auto Return, Normally Closed","description":"\u003cbody\u003e \n\n\n    \u003cstyle\u003e\n        @media only screen and (max-width: 600px) {\n        }\n    \u003c\/style\u003e\n\n\n    \u003cdiv class=\"desktop-only\"\u003e\n     \n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; line-height: 26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 10px; color: black; font-family: Arial;\"\u003eMotorized ball valves present an energy-efficient substitute for solenoid valves, particularly when it comes to prolonged positioning. They primarily consume power during the processes of opening and closing, and the energy consumption is negligible once they are fully opened. This characteristic enables a permanent connection, eliminating the risks of overheating or burnout.\u003c\/p\u003e\n        \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/1.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n             \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n    \u003ctable style=\"border-collapse: collapse;\n                  border: 0px;\n                  width: 100%;\n                  font-family: Arial;\n                  overflow-x: auto;\n                  background-color: #FFFFFF;\"\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"width: 100%;text-align: left;\n                       padding: 0px;\n                       font-size: 16px;\n                       border: 0;\n                       background-color: #FFFFFF;\"\u003e\n                \u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 1\" style=\"width: 100%;height: 100%;\"\u003e\n            \u003c\/td\u003e\n            \u003ctd style=\"width: 100%;text-align: left;\n                       padding: 0px;\n                       font-size: 16px;\n                       border: 0;\n                       background-color: #FFFFFF;\"\u003e\n                \u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 2\" style=\"width: 100%;height: 100%;\"\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/table\u003e\n\u003c\/div\u003e\n          \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e \n \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV20017\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eU.S. Solid\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e3\/4\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eUS Plug\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eUPVC\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e6 - 8 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eAC 110V\/220V\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e5 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e3 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e0℃-90 ℃\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e70,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eStandard\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\/G\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNormally Closed\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e-10℃- 40 ℃\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eIP67\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/CE.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP67 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYES. The motorized ball valve is made of UPVC.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n    \u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP67 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP67. The first digit 6 indicates complete dust - tightness. The second digit 7 means protection from immersion(up to 1M) for a limited time. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/IP67-SS304.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/Manual%20for%20Tonhe.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n    \u003c\/div\u003e\n    \u003cdiv class=\"mobile-only\"\u003e\n        \n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; line-height:26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 0px; color: black; font-family: Arial;\"\u003eMotorized ball valves present an energy-efficient substitute for solenoid valves, particularly when it comes to prolonged positioning. They primarily consume power during the processes of opening and closing, and the energy consumption is negligible once they are fully opened. This characteristic enables a permanent connection, eliminating the risks of overheating or burnout.\u003c\/p\u003e\n            \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/1.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-bottom:10px; margin-top:20px; color: black;\"\u003e\u003cstrong\u003eAPPLICATION\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n    \u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 1\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n    \u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 2\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n\u003c\/div\u003e\n      \u003cp style=\"font-size: 16px; text-align: left; margin-bottom:10px; margin-top:20px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n       \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV20017\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eU.S. Solid\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e3\/4\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eUS Plug\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eUPVC\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e6 - 8 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eAC 110V\/220V\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e5 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e3 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e0℃-90 ℃\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e70,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eStandard\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\/G\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNormally Closed\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e-10℃- 40 ℃\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eIP67\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/CE.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n       \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP67 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYES. The motorized ball valve is made of UPVC.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n    \u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                 \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP67 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP67. The first digit 6 indicates complete dust - tightness. The second digit 7 means protection from immersion(up to 1M) for a limited time. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/IP67-SS304.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material-APP.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/Manual%20for%20Tonhe.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n    \u003cscript\u003e\n\n       \n        const isMobile = window.matchMedia(\"only screen and (max-width: 600px)\").matches;\n        const desktopContent = document.querySelector('.desktop-only');\n        const mobileContent = document.querySelector('.mobile-only');\n\n        if (isMobile) {\n           \n            console.log('');\n            \n            desktopContent.style.display = 'none';\n            mobileContent.style.display = 'block';\n        } else {\n       \n            console.log('');            \n           \n            desktopContent.style.display = 'block';\n            mobileContent.style.display = 'none';\n        }\n    \u003c\/script\u003e\n\n\n\n\u003c\/body\u003e","brand":"U.S. Solid","offers":[{"title":"110V AC \/ NPT","offer_id":47043371696383,"sku":"JFMSV20017","price":109.0,"currency_code":"USD","in_stock":true},{"title":"220V AC \/ G","offer_id":47043371729151,"sku":"JFMSV20017-G","price":84.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/7_2fc77ba1-15ee-4f86-82ed-7f6ba4e0db26.png?v=1752720143"},{"product_id":"1-pvc-motorized-ball-valve-110v-ac-electric-ball-valve-auto-return-normally-closed","title":"1\" PVC Motorized Ball Valve - 110\/220V AC Plastic Electric Ball Valve, Auto Return, Normally Closed","description":"\u003cbody\u003e \n\n\n    \u003cstyle\u003e\n        @media only screen and (max-width: 600px) {\n        }\n    \u003c\/style\u003e\n\n\n    \u003cdiv class=\"desktop-only\"\u003e\n     \n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; line-height: 26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 10px; color: black; font-family: Arial;\"\u003eMotorized ball valves present an energy-efficient substitute for solenoid valves, particularly when it comes to prolonged positioning. They primarily consume power during the processes of opening and closing, and the energy consumption is negligible once they are fully opened. This characteristic enables a permanent connection, eliminating the risks of overheating or burnout.\u003c\/p\u003e\n        \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/1.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n             \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n    \u003ctable style=\"border-collapse: collapse;\n                  border: 0px;\n                  width: 100%;\n                  font-family: Arial;\n                  overflow-x: auto;\n                  background-color: #FFFFFF;\"\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"width: 100%;text-align: left;\n                       padding: 0px;\n                       font-size: 16px;\n                       border: 0;\n                       background-color: #FFFFFF;\"\u003e\n                \u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 1\" style=\"width: 100%;height: 100%;\"\u003e\n            \u003c\/td\u003e\n            \u003ctd style=\"width: 100%;text-align: left;\n                       padding: 0px;\n                       font-size: 16px;\n                       border: 0;\n                       background-color: #FFFFFF;\"\u003e\n                \u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 2\" style=\"width: 100%;height: 100%;\"\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/table\u003e\n\u003c\/div\u003e\n          \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e \n \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV20018\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eU.S. Solid\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eUS Plug\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eUPVC\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e6 - 8 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eAC 110V\/220V\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e5 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e3 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e0℃-90 ℃\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e70,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eStandard\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\/G\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNormally Closed\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e-10℃- 40 ℃\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eIP67\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/CE.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP67 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYES. The motorized ball valve is made of UPVC.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n    \u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP67 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP67. The first digit 6 indicates complete dust - tightness. The second digit 7 means protection from immersion(up to 1M) for a limited time. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/IP67-SS304.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/Manual%20for%20Tonhe.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n    \u003c\/div\u003e\n    \u003cdiv class=\"mobile-only\"\u003e\n        \n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; line-height:26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 0px; color: black; font-family: Arial;\"\u003eMotorized ball valves present an energy-efficient substitute for solenoid valves, particularly when it comes to prolonged positioning. They primarily consume power during the processes of opening and closing, and the energy consumption is negligible once they are fully opened. This characteristic enables a permanent connection, eliminating the risks of overheating or burnout.\u003c\/p\u003e\n            \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/1.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-bottom:10px; margin-top:20px; color: black;\"\u003e\u003cstrong\u003eAPPLICATION\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n    \u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 1\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n    \u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 2\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n\u003c\/div\u003e\n      \u003cp style=\"font-size: 16px; text-align: left; margin-bottom:10px; margin-top:20px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n       \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV20018\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eU.S. Solid\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eUS Plug\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eUPVC\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e6 - 8 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eAC 110V\/220V\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e5 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e3 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e0℃-90 ℃\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e70,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eStandard\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\/G\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNormally Closed\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e-10℃- 40 ℃\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eIP67\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/CE.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n       \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP67 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYES. The motorized ball valve is made of UPVC.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n    \u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                 \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP67 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP67. The first digit 6 indicates complete dust - tightness. The second digit 7 means protection from immersion(up to 1M) for a limited time. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/IP67-SS304.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material-APP.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/Manual%20for%20Tonhe.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n    \u003cscript\u003e\n\n       \n        const isMobile = window.matchMedia(\"only screen and (max-width: 600px)\").matches;\n        const desktopContent = document.querySelector('.desktop-only');\n        const mobileContent = document.querySelector('.mobile-only');\n\n        if (isMobile) {\n           \n            console.log('');\n            \n            desktopContent.style.display = 'none';\n            mobileContent.style.display = 'block';\n        } else {\n       \n            console.log('');            \n           \n            desktopContent.style.display = 'block';\n            mobileContent.style.display = 'none';\n        }\n    \u003c\/script\u003e\n\n\n\n\u003c\/body\u003e","brand":"U.S. Solid","offers":[{"title":"110V AC \/ NPT","offer_id":47043372056831,"sku":"JFMSV20018","price":94.0,"currency_code":"USD","in_stock":true},{"title":"220V AC \/ G","offer_id":47043372089599,"sku":"JFMSV20018-G","price":94.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/7_d60840f5-b6b0-410e-936f-6bf54a649cfb.png?v=1752719424"},{"product_id":"1-1-4-double-union-upvc-motorized-ball-valve-dc-24v-2-wire-auto-return-normally-closed-with-manual-override-epdm-seal","title":"1-1\/4\" Double Union UPVC Motorized Ball Valve - DC 24V, 2-Wire Auto Return, Normally Closed with Manual Override \u0026 EPDM Seal","description":"\u003ch2 data-slate-node=\"element\"\u003e\u003cstrong\u003eIntroduction\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-slate-leaf=\"true\" data-sent-id=\"VMd4PNE2Je\" data-para-id=\"0\" class=\"\"\u003e\u003cspan data-slate-string=\"true\"\u003e\u003cspan data-slate-fragment=\"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\"\u003eOur electric UPVC ball valve series has been upgraded to include three larger sizes: 1-1\/4\", 1-1\/2\", and 2\". These larger valves feature a unique \u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eUS standard socket end\u003c\/strong\u003e\u003c\/span\u003e \u0026amp; \u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003edouble union connection\u003c\/span\u003e\u003c\/strong\u003e—enabling exceptional ease of installation and maintenance with a simple solvent cement bond, \u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eunlike\u003c\/strong\u003e\u003c\/span\u003e threaded NPT or G connections. For other connection standards, please contact our customer service.\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\n\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-slate-leaf=\"true\" data-sent-id=\"eKn4EvRJaB\" data-para-id=\"1\" class=\"\"\u003e\u003cspan data-slate-string=\"true\"\u003eThese valves are \u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003e2-wire auto return\u003c\/strong\u003e\u003c\/span\u003e and remain in a \u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003enormally-closed\u003c\/span\u003e\u003c\/strong\u003e position.\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-slate-leaf=\"true\" data-sent-id=\"V7w18kGA1V\" data-para-id=\"1\" class=\"\"\u003e\u003cspan data-slate-string=\"true\"\u003e They automatically close if power is lost.\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-slate-leaf=\"true\" data-sent-id=\"B4M14NJLpe\" data-para-id=\"1\" class=\"\"\u003e\u003cspan data-slate-string=\"true\"\u003e A manual override is also included for use during power outages.\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-slate-leaf=\"true\" data-sent-id=\"VAJ2GDn4Kz\" data-para-id=\"1\" class=\"\"\u003e\u003cspan data-slate-string=\"true\"\u003e All valves have EPDM seals for reliable performance.\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-slate-leaf=\"true\" data-sent-id=\"VAJ2GDn4Kz\" data-para-id=\"1\" class=\"\"\u003e\u003cspan data-slate-string=\"true\"\u003e\u003cspan data-slate-fragment=\"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\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eNOTE:\u003c\/strong\u003e\u003c\/span\u003e This auto-return ball valve requires a min. power-on duration of 60 seconds (≥60s) . This step is mandatory on first commissioning or after prolonged power cut to ensure reliable auto-reset performance.\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-slate-leaf=\"true\" data-sent-id=\"VAJ2GDn4Kz\" data-para-id=\"1\" class=\"\"\u003e\u003cspan data-slate-string=\"true\"\u003e\u003cspan data-slate-fragment=\"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\"\u003e\u003cspan\u003eTo learn how to use this product, please refer to the\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003e\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/Manual-%20USS-UPVC.pdf\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003euser manual\u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e.\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\n\u003ch2 data-slate-node=\"element\"\u003e\u003cstrong\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-slate-leaf=\"true\" data-sent-id=\"BP90d2vEme\" data-para-id=\"0\" class=\"\"\u003e\u003cspan data-slate-string=\"true\"\u003eSpecifications\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-slate-leaf=\"true\" data-sent-id=\"Bw2DL98jjz\" data-para-id=\"1\" class=\"\"\u003e\u003cspan data-slate-string=\"true\"\u003eModel: USS-MSV467\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-slate-leaf=\"true\" data-sent-id=\"z9ajXPEDJz\" data-para-id=\"2\" class=\"\"\u003e\u003cspan data-slate-string=\"true\"\u003eSize: 1-1\/4\" \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-slate-leaf=\"true\" data-sent-id=\"BaxJd82KJz\" data-para-id=\"3\" class=\"\"\u003e\u003cspan data-slate-string=\"true\"\u003eConnection: Union \u0026amp; Socket End\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-slate-leaf=\"true\" data-sent-id=\"zg5MdYx3Ee\" data-para-id=\"4\" class=\"\"\u003e\u003cspan data-slate-string=\"true\"\u003eSocket Inside Diameter: 42.2mm\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-slate-leaf=\"true\" data-sent-id=\"zrZan5bjLz\" data-para-id=\"5\"\u003e\u003cspan data-slate-string=\"true\"\u003eMaterial: UPVC\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-slate-leaf=\"true\" data-sent-id=\"BZRONq4p5B\" data-para-id=\"6\" class=\"\"\u003e\u003cspan data-slate-string=\"true\"\u003eNormal Position: Normally Closed\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-slate-leaf=\"true\" data-sent-id=\"zlxm27rW1z\" data-para-id=\"7\" class=\"\"\u003e\u003cspan data-slate-string=\"true\"\u003eWorking Voltage: DC 24V\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-slate-leaf=\"true\" data-sent-id=\"BD2jakZR0V\" data-para-id=\"8\" class=\"\"\u003e\u003cspan data-slate-string=\"true\"\u003eMax Power: 36W\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-slate-leaf=\"true\" data-sent-id=\"eLL276pXye\" data-para-id=\"9\" class=\"\"\u003e\u003cspan data-slate-string=\"true\"\u003eMax Torque: 20 N·m\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-slate-leaf=\"true\" data-sent-id=\"Vdompj0KRe\" data-para-id=\"10\" class=\"\"\u003e\u003cspan data-slate-string=\"true\"\u003eMax. Pressure: 232 psi\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\n\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-slate-leaf=\"true\" data-sent-id=\"ebomx1EKpV\" data-para-id=\"11\" class=\"\"\u003e\u003cspan data-slate-string=\"true\"\u003eMedium Temp: 33.8\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-slate-leaf=\"true\" data-sent-id=\"BP90d2vEZe\" data-para-id=\"11\"\u003e\u003cspan data-slate-string=\"true\"\u003e℉ \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-slate-leaf=\"true\" data-sent-id=\"VQaxZEjJ9V\" data-para-id=\"11\"\u003e\u003cspan data-slate-string=\"true\"\u003eto 104\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-slate-leaf=\"true\" data-sent-id=\"Vpgw96Ljre\" data-para-id=\"11\"\u003e\u003cspan data-slate-string=\"true\"\u003e℉\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-slate-leaf=\"true\" data-sent-id=\"VW6NOZM1Ge\" data-para-id=\"12\" class=\"\"\u003e\u003cspan data-slate-string=\"true\"\u003eIP Rating: IP65\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-slate-leaf=\"true\" data-sent-id=\"B89jkb2lpe\" data-para-id=\"13\" class=\"\"\u003e\u003cspan data-slate-string=\"true\"\u003eLife Expectancy: 20,000Cycles\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-slate-leaf=\"true\" data-sent-id=\"V1dK9g4RWe\" data-para-id=\"14\"\u003e\u003cspan data-slate-string=\"true\"\u003eClose\/Open Time: 10-12s\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-slate-leaf=\"true\" data-sent-id=\"Bv2ldwWjPB\" data-para-id=\"15\" class=\"\"\u003e\u003cspan data-slate-string=\"true\"\u003eWiring: 2 wire,auto return\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-slate-leaf=\"true\" data-sent-id=\"ejq2ZMajdB\" data-para-id=\"16\" class=\"\"\u003e\u003cspan data-slate-string=\"true\"\u003eManual Function: Yes\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-slate-leaf=\"true\" data-sent-id=\"VNEOo5821e\" data-para-id=\"17\" class=\"\"\u003e\u003cspan data-slate-string=\"true\"\u003eSignal feedback function: No\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\" data-slate-fragment=\"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\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-slate-leaf=\"true\" data-sent-id=\"zn9m4AljMV\" data-para-id=\"18\"\u003e\u003cspan data-slate-string=\"true\"\u003eSeal: EPDM\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"U.S. Solid","offers":[{"title":"Default Title","offer_id":47291316142335,"sku":"JFMSV00467","price":161.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/1_e994c5be-5ae2-4c5a-ba29-8d05f9297e7b.jpg?v=1758694453"},{"product_id":"1-1-2-double-union-upvc-motorized-ball-valve-dc-24v-2-wire-auto-return-normally-closed-with-manual-override-epdm-seal","title":"1-1\/2\" Double Union UPVC Motorized Ball Valve - DC 24V, 2-Wire Auto Return, Normally Closed with Manual Override \u0026 EPDM Seal","description":"\u003ch2 data-slate-node=\"element\"\u003e\u003cstrong\u003eIntroduction\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\n\u003cspan data-slate-node=\"text\"\u003e\u003cspan class=\"\" data-para-id=\"1\" data-sent-id=\"VAJ2GDn4Kz\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-string=\"true\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan class=\"\" data-para-id=\"0\" data-sent-id=\"VMd4PNE2Je\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-string=\"true\"\u003e\u003cspan data-slate-fragment=\"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\"\u003eOur electric UPVC ball valve series has been upgraded to include three larger sizes: 1-1\/4\", 1-1\/2\", and 2\". These larger valves feature a unique \u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eUS standard socket end\u003c\/strong\u003e\u003c\/span\u003e \u0026amp; \u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003edouble union connection\u003c\/span\u003e\u003c\/strong\u003e—enabling exceptional ease of installation and maintenance with a simple solvent cement bond, \u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eunlike\u003c\/strong\u003e\u003c\/span\u003e threaded NPT or G connections. For other connection standards, please contact our customer service.\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\n\u003cspan data-slate-node=\"text\"\u003e\u003cspan class=\"\" data-para-id=\"1\" data-sent-id=\"eKn4EvRJaB\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-string=\"true\"\u003eThese valves are \u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003e2-wire auto return\u003c\/strong\u003e\u003c\/span\u003e and remain in a \u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003enormally-closed\u003c\/span\u003e\u003c\/strong\u003e position.\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan class=\"\" data-para-id=\"1\" data-sent-id=\"V7w18kGA1V\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-string=\"true\"\u003e They automatically close if power is lost.\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan class=\"\" data-para-id=\"1\" data-sent-id=\"B4M14NJLpe\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-string=\"true\"\u003e A manual override is also included for use during power outages.\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan class=\"\" data-para-id=\"1\" data-sent-id=\"VAJ2GDn4Kz\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-string=\"true\"\u003e All valves have EPDM seals for reliable performance.\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan class=\"\" data-para-id=\"1\" data-sent-id=\"VAJ2GDn4Kz\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-string=\"true\"\u003e\u003cspan data-slate-fragment=\"JTVCJTdCJTIydHlwZSUyMiUzQSUyMnBhcmFncmFwaCUyMiUyQyUyMmNoaWxkcmVuJTIyJTNBJTVCJTdCJTIyaWQlMjIlM0ElMjJLWTVMTzRWMUFyJTIyJTJDJTIycGFyYUlkeCUyMiUzQTAlMkMlMjJzcmMlMjIlM0ElMjJOT1RFJTNBJTIwVGhpcyUyMGF1dG8tcmV0dXJuJTIwYmFsbCUyMHZhbHZlJTIwcmVxdWlyZXMlMjBhJTIwbWluLiUyMHBvd2VyLW9uJTIwZHVyYXRpb24lMjBvZiUyMDYwJTIwc2Vjb25kcyUyMCglRTIlODklQTUlMjA2MHMpJTIwLiUyMFRoaXMlMjBzdGVwJTIwaXMlMjBtYW5kYXRvcnklMjBvbiUyMGZpcnN0JTIwY29tbWlzc2lvbmluZyUyMG9yJTIwYWZ0ZXIlMjBwcm9sb25nZWQlMjBwb3dlciUyMGN1dCUyMHRvJTIwZW5zdXJlJTIwcmVsaWFibGUlMjBhdXRvLXJlc2V0JTIwcGVyZm9ybWFuY2UuJTIyJTJDJTIyZHN0JTIyJTNBJTIyJUU2JUIzJUE4JUU2JTg0JThGJUVGJUJDJTlBJUU2JUFEJUE0JUU4JTg3JUFBJUU1JThBJUE4JUU1JTlCJTlFJUU2JUI1JTgxJUU3JTkwJTgzJUU5JTk4JTgwJUU5JTlDJTgwJUU4JUE2JTgxJUU4JTg3JUIzJUU1JUIwJTkxNjAlRTclQTclOTIlRUYlQkMlODglRTIlODklQTU2MCVFNyVBNyU5MiVFRiVCQyU4OSVFNyU5QSU4NCVFOSU4MCU5QSVFNyU5NCVCNSVFNiU5NyVCNiVFOSU5NyVCNCVFMyU4MCU4MiVFOSVBNiU5NiVFNiVBQyVBMSVFOCVCMCU4MyVFOCVBRiU5NSVFNiU4OCU5NiVFOSU5NSVCRiVFNiU5NyVCNiVFOSU5NyVCNCVFNiU5NiVBRCVFNyU5NCVCNSVFNSU5MCU4RSVFRiVCQyU4QyVFNSVCRiU4NSVFOSVBMSVCQiVFNiU4OSVBNyVFOCVBMSU4QyVFNiVBRCVBNCVFNiVBRCVBNSVFOSVBQSVBNCVFRiVCQyU4QyVFNCVCQiVBNSVFNyVBMSVBRSVFNCVCRiU5RCVFNSU4RiVBRiVFOSU5RCVBMCVFNyU5QSU4NCVFOCU4NyVBQSVFNSU4QSVBOCVFNSVBNCU4RCVFNCVCRCU4RCVFNiU4MCVBNyVFOCU4MyVCRCVFMyU4MCU4MiUyMiUyQyUyMm1ldGFkYXRhJTIyJTNBJTIyJTIyJTJDJTIybWF0Y2hlcyUyMiUzQW51bGwlMkMlMjJ0cmFuc2xhdGVkQnklMjIlM0FudWxsJTJDJTIybWV0YURhdGElMjIlM0ElNUIlNUQlMkMlMjJ0ZXh0JTIyJTNBJTIyTk9URSUzQSUyMFRoaXMlMjBhdXRvLXJldHVybiUyMGJhbGwlMjB2YWx2ZSUyMHJlcXVpcmVzJTIwYSUyMG1pbi4lMjBwb3dlci1vbiUyMGR1cmF0aW9uJTIwb2YlMjA2MCUyMHNlY29uZHMlMjAoJUUyJTg5JUE1JTIwNjBzKSUyMC4lMjBUaGlzJTIwc3RlcCUyMGlzJTIwbWFuZGF0b3J5JTIwb24lMjBmaXJzdCUyMGNvbW1pc3Npb25pbmclMjBvciUyMGFmdGVyJTIwcHJvbG9uZ2VkJTIwcG93ZXIlMjBjdXQlMjB0byUyMGVuc3VyZSUyMHJlbGlhYmxlJTIwYXV0by1yZXNldCUyMHBlcmZvcm1hbmNlLiUyMiU3RCU1RCU3RCU1RA==\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eNOTE:\u003c\/strong\u003e\u003c\/span\u003e This auto-return ball valve requires a min. power-on duration of 60 seconds (≥60s) . This step is mandatory on first commissioning or after prolonged power cut to ensure reliable auto-reset performance.\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan class=\"\" data-para-id=\"1\" data-sent-id=\"VAJ2GDn4Kz\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-string=\"true\"\u003e\u003cspan data-slate-fragment=\"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\"\u003e\u003cspan\u003eTo learn how to use this product, please refer to the\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003e\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/Manual-%20USS-UPVC.pdf\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003euser manual\u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e.\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\n\u003ch2 data-slate-node=\"element\"\u003e\u003cstrong\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan class=\"\" data-para-id=\"0\" data-sent-id=\"BP90d2vEme\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-string=\"true\"\u003eSpecifications\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan class=\"\" data-para-id=\"1\" data-sent-id=\"Bw2DL98jjz\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-string=\"true\"\u003eModel: USS-MSV468\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan class=\"\" data-para-id=\"2\" data-sent-id=\"z9ajXPEDJz\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-string=\"true\"\u003eSize: 1-1\/2\" \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003eConnection: Union \u0026amp;amp; Socket End\u003cbr\u003eSocket Inside Diameter: 48.3mm\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-para-id=\"5\" data-sent-id=\"zrZan5bjLz\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-string=\"true\"\u003eMaterial: UPVC\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan class=\"\" data-para-id=\"6\" data-sent-id=\"BZRONq4p5B\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-string=\"true\"\u003eNormal Position: Normally Closed\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan class=\"\" data-para-id=\"7\" data-sent-id=\"zlxm27rW1z\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-string=\"true\"\u003eWorking Voltage: DC 24V\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan class=\"\" data-para-id=\"8\" data-sent-id=\"BD2jakZR0V\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-string=\"true\"\u003eMax Power: 36W\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan class=\"\" data-para-id=\"9\" data-sent-id=\"eLL276pXye\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-string=\"true\"\u003eMax Torque: 20 N·m\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan class=\"\" data-para-id=\"10\" data-sent-id=\"Vdompj0KRe\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-string=\"true\"\u003eMax. Pressure: 232 psi\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\n\u003cspan data-slate-node=\"text\"\u003e\u003cspan class=\"\" data-para-id=\"11\" data-sent-id=\"ebomx1EKpV\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-string=\"true\"\u003eMedium Temp: 33.8\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-para-id=\"11\" data-sent-id=\"BP90d2vEZe\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-string=\"true\"\u003e℉ \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-para-id=\"11\" data-sent-id=\"VQaxZEjJ9V\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-string=\"true\"\u003eto 104\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-para-id=\"11\" data-sent-id=\"Vpgw96Ljre\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-string=\"true\"\u003e℉\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan class=\"\" data-para-id=\"12\" data-sent-id=\"VW6NOZM1Ge\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-string=\"true\"\u003eIP Rating: IP65\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan class=\"\" data-para-id=\"13\" data-sent-id=\"B89jkb2lpe\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-string=\"true\"\u003eLife Expectancy: 20,000Cycles\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-para-id=\"14\" data-sent-id=\"V1dK9g4RWe\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-string=\"true\"\u003eClose\/Open Time: 10-12s\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan class=\"\" data-para-id=\"15\" data-sent-id=\"Bv2ldwWjPB\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-string=\"true\"\u003eWiring: 2 wire,auto return\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan class=\"\" data-para-id=\"16\" data-sent-id=\"ejq2ZMajdB\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-string=\"true\"\u003eManual Function: Yes\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan class=\"\" data-para-id=\"17\" data-sent-id=\"VNEOo5821e\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-string=\"true\"\u003eSignal feedback function: No\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-fragment=\"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\" data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-para-id=\"18\" data-sent-id=\"zn9m4AljMV\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-string=\"true\"\u003eSeal: EPDM\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"U.S. Solid","offers":[{"title":"Default Title","offer_id":47294841422079,"sku":"JFMSV00468","price":171.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/2_9c8be148-836c-4030-8810-599b2b24aea6.jpg?v=1758694502"},{"product_id":"2-double-union-upvc-motorized-ball-valve-dc-24v-2-wire-auto-return-normally-closed-with-manual-override-epdm-seal","title":"2\" Double Union UPVC Motorized Ball Valve - DC 24V, 2-Wire Auto Return, Normally Closed with Manual Override \u0026 EPDM Seal","description":"\u003ch2 data-slate-node=\"element\"\u003e\u003cstrong\u003eIntroduction\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\n\u003cspan data-slate-node=\"text\"\u003e\u003cspan class=\"\" data-para-id=\"1\" data-sent-id=\"VAJ2GDn4Kz\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-string=\"true\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-slate-leaf=\"true\" data-sent-id=\"VMd4PNE2Je\" data-para-id=\"0\" class=\"\"\u003e\u003cspan data-slate-string=\"true\"\u003e\u003cspan data-slate-fragment=\"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\"\u003eOur electric UPVC ball valve series has been upgraded to include three larger sizes: 1-1\/4\", 1-1\/2\", and 2\". These larger valves feature a unique \u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eUS standard socket end\u003c\/strong\u003e\u003c\/span\u003e \u0026amp; \u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003edouble union connection\u003c\/span\u003e\u003c\/strong\u003e—enabling exceptional ease of installation and maintenance with a simple solvent cement bond, \u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eunlike\u003c\/strong\u003e\u003c\/span\u003e threaded NPT or G connections. For other connection standards, please contact our customer service.\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\n\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-slate-leaf=\"true\" data-sent-id=\"eKn4EvRJaB\" data-para-id=\"1\" class=\"\"\u003e\u003cspan data-slate-string=\"true\"\u003eThese valves are \u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003e2-wire auto return\u003c\/strong\u003e\u003c\/span\u003e and remain in a \u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003enormally-closed\u003c\/span\u003e\u003c\/strong\u003e position.\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-slate-leaf=\"true\" data-sent-id=\"V7w18kGA1V\" data-para-id=\"1\" class=\"\"\u003e\u003cspan data-slate-string=\"true\"\u003e They automatically close if power is lost.\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-slate-leaf=\"true\" data-sent-id=\"B4M14NJLpe\" data-para-id=\"1\" class=\"\"\u003e\u003cspan data-slate-string=\"true\"\u003e A manual override is also included for use during power outages.\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-slate-leaf=\"true\" data-sent-id=\"VAJ2GDn4Kz\" data-para-id=\"1\" class=\"\"\u003e\u003cspan data-slate-string=\"true\"\u003e All valves have EPDM seals for reliable performance.\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-slate-leaf=\"true\" data-sent-id=\"VAJ2GDn4Kz\" data-para-id=\"1\" class=\"\"\u003e\u003cspan data-slate-string=\"true\"\u003e\u003cspan data-slate-fragment=\"JTVCJTdCJTIydHlwZSUyMiUzQSUyMnBhcmFncmFwaCUyMiUyQyUyMmNoaWxkcmVuJTIyJTNBJTVCJTdCJTIyaWQlMjIlM0ElMjJLWTVMTzRWMUFyJTIyJTJDJTIycGFyYUlkeCUyMiUzQTAlMkMlMjJzcmMlMjIlM0ElMjJOT1RFJTNBJTIwVGhpcyUyMGF1dG8tcmV0dXJuJTIwYmFsbCUyMHZhbHZlJTIwcmVxdWlyZXMlMjBhJTIwbWluLiUyMHBvd2VyLW9uJTIwZHVyYXRpb24lMjBvZiUyMDYwJTIwc2Vjb25kcyUyMCglRTIlODklQTUlMjA2MHMpJTIwLiUyMFRoaXMlMjBzdGVwJTIwaXMlMjBtYW5kYXRvcnklMjBvbiUyMGZpcnN0JTIwY29tbWlzc2lvbmluZyUyMG9yJTIwYWZ0ZXIlMjBwcm9sb25nZWQlMjBwb3dlciUyMGN1dCUyMHRvJTIwZW5zdXJlJTIwcmVsaWFibGUlMjBhdXRvLXJlc2V0JTIwcGVyZm9ybWFuY2UuJTIyJTJDJTIyZHN0JTIyJTNBJTIyJUU2JUIzJUE4JUU2JTg0JThGJUVGJUJDJTlBJUU2JUFEJUE0JUU4JTg3JUFBJUU1JThBJUE4JUU1JTlCJTlFJUU2JUI1JTgxJUU3JTkwJTgzJUU5JTk4JTgwJUU5JTlDJTgwJUU4JUE2JTgxJUU4JTg3JUIzJUU1JUIwJTkxNjAlRTclQTclOTIlRUYlQkMlODglRTIlODklQTU2MCVFNyVBNyU5MiVFRiVCQyU4OSVFNyU5QSU4NCVFOSU4MCU5QSVFNyU5NCVCNSVFNiU5NyVCNiVFOSU5NyVCNCVFMyU4MCU4MiVFOSVBNiU5NiVFNiVBQyVBMSVFOCVCMCU4MyVFOCVBRiU5NSVFNiU4OCU5NiVFOSU5NSVCRiVFNiU5NyVCNiVFOSU5NyVCNCVFNiU5NiVBRCVFNyU5NCVCNSVFNSU5MCU4RSVFRiVCQyU4QyVFNSVCRiU4NSVFOSVBMSVCQiVFNiU4OSVBNyVFOCVBMSU4QyVFNiVBRCVBNCVFNiVBRCVBNSVFOSVBQSVBNCVFRiVCQyU4QyVFNCVCQiVBNSVFNyVBMSVBRSVFNCVCRiU5RCVFNSU4RiVBRiVFOSU5RCVBMCVFNyU5QSU4NCVFOCU4NyVBQSVFNSU4QSVBOCVFNSVBNCU4RCVFNCVCRCU4RCVFNiU4MCVBNyVFOCU4MyVCRCVFMyU4MCU4MiUyMiUyQyUyMm1ldGFkYXRhJTIyJTNBJTIyJTIyJTJDJTIybWF0Y2hlcyUyMiUzQW51bGwlMkMlMjJ0cmFuc2xhdGVkQnklMjIlM0FudWxsJTJDJTIybWV0YURhdGElMjIlM0ElNUIlNUQlMkMlMjJ0ZXh0JTIyJTNBJTIyTk9URSUzQSUyMFRoaXMlMjBhdXRvLXJldHVybiUyMGJhbGwlMjB2YWx2ZSUyMHJlcXVpcmVzJTIwYSUyMG1pbi4lMjBwb3dlci1vbiUyMGR1cmF0aW9uJTIwb2YlMjA2MCUyMHNlY29uZHMlMjAoJUUyJTg5JUE1JTIwNjBzKSUyMC4lMjBUaGlzJTIwc3RlcCUyMGlzJTIwbWFuZGF0b3J5JTIwb24lMjBmaXJzdCUyMGNvbW1pc3Npb25pbmclMjBvciUyMGFmdGVyJTIwcHJvbG9uZ2VkJTIwcG93ZXIlMjBjdXQlMjB0byUyMGVuc3VyZSUyMHJlbGlhYmxlJTIwYXV0by1yZXNldCUyMHBlcmZvcm1hbmNlLiUyMiU3RCU1RCU3RCU1RA==\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eNOTE:\u003c\/strong\u003e\u003c\/span\u003e This auto-return ball valve requires a min. power-on duration of 60 seconds (≥60s) . This step is mandatory on first commissioning or after prolonged power cut to ensure reliable auto-reset performance.\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-slate-leaf=\"true\" data-sent-id=\"VAJ2GDn4Kz\" data-para-id=\"1\" class=\"\"\u003e\u003cspan data-slate-string=\"true\"\u003e\u003cspan data-slate-fragment=\"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\"\u003e\u003cspan\u003eTo learn how to use this product, please refer to the\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003e\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/Manual-%20USS-UPVC.pdf\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003euser manual\u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e.\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\n\u003ch2 data-slate-node=\"element\"\u003e\u003cstrong\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan class=\"\" data-para-id=\"0\" data-sent-id=\"BP90d2vEme\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-string=\"true\"\u003eSpecifications\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan class=\"\" data-para-id=\"1\" data-sent-id=\"Bw2DL98jjz\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-string=\"true\"\u003eModel: USS-MSV469\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan class=\"\" data-para-id=\"2\" data-sent-id=\"z9ajXPEDJz\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-string=\"true\"\u003eSize: 2\" \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003eConnection: Union \u0026amp;amp; Socket End\u003cbr\u003eSocket Inside Diameter: 60.3mm\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-para-id=\"5\" data-sent-id=\"zrZan5bjLz\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-string=\"true\"\u003eMaterial: UPVC\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan class=\"\" data-para-id=\"6\" data-sent-id=\"BZRONq4p5B\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-string=\"true\"\u003eNormal Position: Normally Closed\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan class=\"\" data-para-id=\"7\" data-sent-id=\"zlxm27rW1z\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-string=\"true\"\u003eWorking Voltage: DC 24V\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan class=\"\" data-para-id=\"8\" data-sent-id=\"BD2jakZR0V\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-string=\"true\"\u003eMax Power: 36W\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan class=\"\" data-para-id=\"9\" data-sent-id=\"eLL276pXye\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-string=\"true\"\u003eMax Torque: 20 N·m\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan class=\"\" data-para-id=\"10\" data-sent-id=\"Vdompj0KRe\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-string=\"true\"\u003eMax. Pressure: 232 psi\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\n\u003cspan data-slate-node=\"text\"\u003e\u003cspan class=\"\" data-para-id=\"11\" data-sent-id=\"ebomx1EKpV\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-string=\"true\"\u003eMedium Temp: 33.8\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-para-id=\"11\" data-sent-id=\"BP90d2vEZe\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-string=\"true\"\u003e℉ \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-para-id=\"11\" data-sent-id=\"VQaxZEjJ9V\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-string=\"true\"\u003eto 104\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-para-id=\"11\" data-sent-id=\"Vpgw96Ljre\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-string=\"true\"\u003e℉\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan class=\"\" data-para-id=\"12\" data-sent-id=\"VW6NOZM1Ge\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-string=\"true\"\u003eIP Rating: IP65\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan class=\"\" data-para-id=\"13\" data-sent-id=\"B89jkb2lpe\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-string=\"true\"\u003eLife Expectancy: 20,000Cycles\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-para-id=\"14\" data-sent-id=\"V1dK9g4RWe\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-string=\"true\"\u003eClose\/Open Time: 10-12s\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan class=\"\" data-para-id=\"15\" data-sent-id=\"Bv2ldwWjPB\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-string=\"true\"\u003eWiring: 2 wire,auto return\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan class=\"\" data-para-id=\"16\" data-sent-id=\"ejq2ZMajdB\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-string=\"true\"\u003eManual Function: Yes\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan class=\"\" data-para-id=\"17\" data-sent-id=\"VNEOo5821e\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-string=\"true\"\u003eSignal feedback function: No\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-fragment=\"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\" data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-para-id=\"18\" data-sent-id=\"zn9m4AljMV\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-string=\"true\"\u003eSeal: EPDM\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"U.S. Solid","offers":[{"title":"Default Title","offer_id":47294841880831,"sku":"JFMSV00469","price":181.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/3_c2e2f334-14b7-4e14-892b-83f625b659fa.jpg?v=1758694547"},{"product_id":"20-pack-1-2-upvc-motorized-ball-valve-9-36v-ac-dc-plastic-electrical-ball-valve-with-full-port-2-wire-auto-return-normally-closed","title":"20-Pack 1\/2\" UPVC Motorized Ball Valve - 9-36V AC\/DC Plastic Electrical Ball Valve with Full Port, 2 Wire Auto Return, Normally Closed","description":"\u003cbody\u003e \n\n\n    \u003cstyle\u003e\n        @media only screen and (max-width: 600px) {\n        }\n    \u003c\/style\u003e\n\n\n    \u003cdiv class=\"desktop-only\"\u003e\n        \n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; line-height: 26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 10px; color: black; font-family: Arial;\"\u003eMotorized ball valves are a vital piece of equipment in numerous applications. This model opens and closes in 6-8 seconds, and remains in its new position while expending almost no energy. This is a key difference between motorized ball valves and many solenoid valves. Most solenoid valves are energized continuously when in a new position, while motorized ball valves expend energy only when changing from open to close, or vice versa.\u003cbr\u003eThe 2 wire auto return model is perfect for situations where the valve needs to be closed in case of power loss. The valve can be energized to open, and left hooked up, with negligible energy used once fully opened. To close, simply shutoff power to the valve. This valve is convenient because it can be operated with a simple on off switch. When on, it will remain open, when turned off (or power is lost for some other reason) the valve automatically closes.\u003c\/p\u003e\n        \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/1.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n             \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n    \u003ctable style=\"border-collapse: collapse;\n                  border: 0px;\n                  width: 100%;\n                  font-family: Arial;\n                  overflow-x: auto;\n                  background-color: #FFFFFF;\"\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"width: 100%;text-align: left;\n                       padding: 0px;\n                       font-size: 16px;\n                       border: 0;\n                       background-color: #FFFFFF;\"\u003e\n                \u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 1\/2\" style=\"width: 100%;height: 100%;\"\u003e\n            \u003c\/td\u003e\n            \u003ctd style=\"width: 100%;text-align: left;\n                       padding: 0px;\n                       font-size: 16px;\n                       border: 0;\n                       background-color: #FFFFFF;\"\u003e\n                \u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 1\/2\" style=\"width: 100%;height: 100%;\"\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/table\u003e\n\u003c\/div\u003e\n          \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e \n \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV00091\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eU.S. Solid\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1\/2\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e2 Wire Auto Return\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eUPVC\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e6 - 8 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e9-36V AC\/DC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e5 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e2 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1°C to 55°C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e50,000 to 80,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eFull\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\/G\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNormally Closed\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1°C to 50°C\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eIP65\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/CE\/CE-EMC.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP65 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYES. The motorized ball valve is made of lead-free UPVC.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n    \u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP65 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP65. The first digit 6 indicates complete dust - tightness. The second digit 5 means protection against water jets from any direction. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/valve%20model.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAT MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/JFMSV-User-manual.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n    \u003c\/div\u003e\n    \u003cdiv class=\"mobile-only\"\u003e\n        \n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; line-height:26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 0px; color: black; font-family: Arial;\"\u003eMotorized ball valves are a vital piece of equipment in numerous applications. This model opens and closes in 6-8 seconds, and remains in its new position while expending almost no energy. This is a key difference between motorized ball valves and many solenoid valves. Most solenoid valves are energized continuously when in a new position, while motorized ball valves expend energy only when changing from open to close, or vice versa.\u003cbr\u003eThe 2 wire auto return model is perfect for situations where the valve needs to be closed in case of power loss. The valve can be energized to open, and left hooked up, with negligible energy used once fully opened. To close, simply shutoff power to the valve. This valve is convenient because it can be operated with a simple on off switch. When on, it will remain open, when turned off (or power is lost for some other reason) the valve automatically closes.\u003c\/p\u003e\n            \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/1.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-bottom:10px; margin-top:20px; color: black;\"\u003e\u003cstrong\u003eAPPLICATION\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n    \u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 1\/2\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n    \u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 1\/2\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n\u003c\/div\u003e\n      \u003cp style=\"font-size: 16px; text-align: left; margin-bottom:10px; margin-top:20px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV00091\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eU.S. Solid\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1\/2\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e2 Wire Auto Return\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eUPVC\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e6 - 8 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e9-36V AC\/DC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e5 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e2 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1°C to 55°C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e50,000 to 80,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eFull\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\/G\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNormally Closed\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1°C to 50°C\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eIP65\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/CE\/CE-EMC.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP65 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYES. The motorized ball valve is made of lead-free UPVC.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n    \u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP65 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP65. The first digit 6 indicates complete dust - tightness. The second digit 5 means protection against water jets from any direction. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/valve%20model.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAT MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material-APP.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/JFMSV-User-manual.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n    \u003cscript\u003e\n\n        \n        const isMobile = window.matchMedia(\"only screen and (max-width: 600px)\").matches;\n        const desktopContent = document.querySelector('.desktop-only');\n        const mobileContent = document.querySelector('.mobile-only');\n\n        if (isMobile) {\n            \n            console.log('');\n           \n            desktopContent.style.display = 'none';\n            mobileContent.style.display = 'block';\n        } else {\n           \n            console.log('');            \n            \n            desktopContent.style.display = 'block';\n            mobileContent.style.display = 'none';\n        }\n    \u003c\/script\u003e\n\n\n\n\u003c\/body\u003e","brand":"U.S. Solid","offers":[{"title":"Default Title","offer_id":47601243554047,"sku":"JFMSV00091-CP20","price":699.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/1__04005.1697099836.1280.1280.jpg?v=1731291530"},{"product_id":"1-1-4-upvc-motorized-ball-valve-full-port-9-24v-ac-dc-2-wire-auto-return-ip67-normally-closed-with-manual-reset","title":"1-1\/4\" UPVC Motorized Ball Valve, Full Port, 9–24V AC\/DC, 2-Wire Auto Return, IP67, Normally Closed with Manual Reset","description":"","brand":"U.S. Solid","offers":[{"title":"NPT","offer_id":47614018355455,"sku":"JFMSV50020","price":171.69,"currency_code":"USD","in_stock":true},{"title":"G","offer_id":47614018388223,"sku":"JFMSV50020-G","price":171.69,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/1_d34f4be6-df3d-40dc-851e-0989627d1ae9.png?v=1778573132"},{"product_id":"1-1-2-upvc-motorized-ball-valve-full-port-9-24v-ac-dc-2-wire-auto-return-ip67-normally-closed-with-manual-reset","title":"1-1\/2\" UPVC Motorized Ball Valve, Full Port, 9–24V AC\/DC, 2-Wire Auto Return, IP67, Normally Closed with Manual Reset","description":"","brand":"U.S. Solid","offers":[{"title":"NPT","offer_id":47614019207423,"sku":"JFMSV50021","price":181.79,"currency_code":"USD","in_stock":true},{"title":"G","offer_id":47614019240191,"sku":"JFMSV50021-G","price":181.79,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/1_c1ee0307-5c60-4197-b523-6d9873d59888.png?v=1778573237"},{"product_id":"2-upvc-motorized-ball-valve-full-port-9-24v-ac-dc-2-wire-auto-return-ip67-normally-closed-with-manual-reset","title":"2\" UPVC Motorized Ball Valve, Full Port, 9–24V AC\/DC, 2-Wire Auto Return, IP67, Normally Closed with Manual Reset","description":"","brand":"U.S. Solid","offers":[{"title":"NPT","offer_id":47614019666175,"sku":"JFMSV50022","price":201.99,"currency_code":"USD","in_stock":true},{"title":"G","offer_id":47614019698943,"sku":"JFMSV50022-G","price":201.99,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/1_f2f8ce5e-6ccc-4dd6-8d50-6621ecc096d3.png?v=1778573362"},{"product_id":"1-2-3-way-upvc-motorized-ball-valve-l-type-9-24v-ac-dc-2-wire-auto-return-ip67-full-port-normally-closed-with-manual-reset","title":"1\/2\" 3 Way UPVC Motorized Ball Valve, L Type, 9–24V AC\/DC, 2-Wire Auto Return, IP67 Full Port, Normally Closed with Manual Reset","description":"","brand":"U.S. Solid","offers":[{"title":"NPT","offer_id":47615636177151,"sku":"JFMSV50023","price":232.29,"currency_code":"USD","in_stock":true},{"title":"G","offer_id":47615636209919,"sku":"JFMSV50023-G","price":232.29,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/1_ef64c431-4e45-4059-9010-e9c3e3d561f0.png?v=1778573537"},{"product_id":"3-4-3-way-upvc-motorized-ball-valve-l-type-9-24v-ac-dc-2-wire-auto-return-ip67-full-port-normally-closed-with-manual-reset","title":"3\/4\" 3 Way UPVC Motorized Ball Valve, L Type, 9–24V AC\/DC, 2-Wire Auto Return, IP67 Full Port, Normally Closed with Manual Reset","description":"","brand":"U.S. Solid","offers":[{"title":"NPT","offer_id":47615636701439,"sku":"JFMSV50024","price":252.49,"currency_code":"USD","in_stock":true},{"title":"G","offer_id":47615636734207,"sku":"JFMSV50024-G","price":252.49,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/1_8a49996d-4b37-43c8-947c-dad58f4f5782.png?v=1778573593"},{"product_id":"1-3-way-upvc-motorized-ball-valve-l-type-9-24v-ac-dc-2-wire-auto-return-ip67-full-port-normally-closed-with-manual-reset","title":"1\" 3 Way UPVC Motorized Ball Valve, L Type, 9–24V AC\/DC, 2-Wire Auto Return, IP67 Full Port, Normally Closed with Manual Reset","description":"","brand":"U.S. Solid","offers":[{"title":"NPT","offer_id":47615645483263,"sku":"JFMSV50025","price":272.69,"currency_code":"USD","in_stock":true},{"title":"G","offer_id":47615645516031,"sku":"JFMSV50025-G","price":272.69,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/1_54693068-0a0c-48a8-80d1-80a021e89781.png?v=1778573682"},{"product_id":"1-1-4-3-way-upvc-motorized-ball-valve-l-type-9-24v-ac-dc-2-wire-auto-return-ip67-full-port-normally-closed-with-manual-reset","title":"1-1\/4\" 3 Way UPVC Motorized Ball Valve, L Type, 9–24V AC\/DC, 2-Wire Auto Return, IP67 Full Port, Normally Closed with Manual Reset","description":"","brand":"U.S. Solid","offers":[{"title":"NPT","offer_id":47615650103551,"sku":"JFMSV50026","price":292.89,"currency_code":"USD","in_stock":true},{"title":"G","offer_id":47615650136319,"sku":"JFMSV50026-G","price":292.89,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/1_1d4c0b77-2ffb-4e2c-8bf4-fe34c17c7c6b.png?v=1778573685"},{"product_id":"1-1-2-3-way-upvc-motorized-ball-valve-l-type-9-24v-ac-dc-2-wire-auto-return-ip67-full-port-normally-closed-with-manual-reset","title":"1-1\/2\" 3 Way UPVC Motorized Ball Valve, L Type, 9–24V AC\/DC, 2-Wire Auto Return, IP67 Full Port, Normally Closed with Manual Reset","description":"","brand":"U.S. Solid","offers":[{"title":"NPT","offer_id":47615652954367,"sku":"JFMSV50027","price":345.07,"currency_code":"USD","in_stock":true},{"title":"G","offer_id":47615652987135,"sku":"JFMSV50027-G","price":343.39,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/1_3d0a8a54-5260-4ad2-8f96-5f11c719e9be.png?v=1778573764"},{"product_id":"2-3-way-upvc-motorized-ball-valve-l-type-9-24v-ac-dc-2-wire-auto-return-ip67-full-port-normally-closed-with-manual-reset","title":"2\" 3 Way UPVC Motorized Ball Valve, L Type, 9–24V AC\/DC, 2-Wire Auto Return, IP67 Full Port, Normally Closed with Manual Reset","description":"","brand":"U.S. Solid","offers":[{"title":"NPT","offer_id":47615659376895,"sku":"JFMSV50028","price":355.17,"currency_code":"USD","in_stock":true},{"title":"G","offer_id":47615659409663,"sku":"JFMSV50028-G","price":353.49,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/1_a1e1c429-857b-447d-afc4-d7e078dd4ec8.png?v=1778573764"},{"product_id":"1-2-upvc-motorized-ball-valve-85-265v-ac-plastic-electrical-ball-valve-with-full-port-2-wire-auto-return-normally-open","title":"1\/2\" UPVC Motorized Ball Valve - 85-265V AC Plastic Electrical Ball Valve with Full Port, 2 Wire Auto Return, Normally Open","description":"\u003cbody\u003e \n\n\n    \u003cstyle\u003e\n        @media only screen and (max-width: 600px) {\n        }\n    \u003c\/style\u003e\n\n\n    \u003cdiv class=\"desktop-only\"\u003e\n        \n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; line-height: 26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 10px; color: black; font-family: Arial;\"\u003eMotorized ball valves are a vital piece of equipment in numerous applications. This model opens and closes in 6-8 seconds, and remains in its new position while expending almost no energy. This is a key difference between motorized ball valves and many solenoid valves. Most solenoid valves are energized continuously when in a new position, while motorized ball valves expend energy only when changing from open to close, or vice versa.\u003cbr\u003eThe 2 wire auto return model is perfect for situations where the valve needs to be closed in case of power loss. The valve can be energized to open, and left hooked up, with negligible energy used once fully opened. To close, simply shutoff power to the valve. This valve is convenient because it can be operated with a simple on off switch. When on, it will remain open, when turned off (or power is lost for some other reason) the valve automatically closes.\u003c\/p\u003e\n        \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/1.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n             \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n    \u003ctable style=\"border-collapse: collapse;\n                  border: 0px;\n                  width: 100%;\n                  font-family: Arial;\n                  overflow-x: auto;\n                  background-color: #FFFFFF;\"\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"width: 100%;text-align: left;\n                       padding: 0px;\n                       font-size: 16px;\n                       border: 0;\n                       background-color: #FFFFFF;\"\u003e\n                \u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 1\/2\" style=\"width: 100%;height: 100%;\"\u003e\n            \u003c\/td\u003e\n            \u003ctd style=\"width: 100%;text-align: left;\n                       padding: 0px;\n                       font-size: 16px;\n                       border: 0;\n                       background-color: #FFFFFF;\"\u003e\n                \u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 1\/2\" style=\"width: 100%;height: 100%;\"\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/table\u003e\n\u003c\/div\u003e\n          \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e \n \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV00501\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eU.S. Solid\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1\/2\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e2 Wire Auto Return\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eUPVC\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e6 - 8 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eAC 85-265V\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e10 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e2 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1°C to 55°C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e50,000 to 80,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eFull\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\/G\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNormally Open\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1°C to 50°C\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eIP65\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/CE.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP65 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYES. The motorized ball valve is made of lead-free UPVC.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n    \u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP65 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP65. The first digit 6 indicates complete dust - tightness. The second digit 5 means protection against water jets from any direction. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/valve%20model.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/JFMSV-User-manual.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n    \u003c\/div\u003e\n    \u003cdiv class=\"mobile-only\"\u003e\n       \n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; line-height:26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 0px; color: black; font-family: Arial;\"\u003eMotorized ball valves are a vital piece of equipment in numerous applications. This model opens and closes in 6-8 seconds, and remains in its new position while expending almost no energy. This is a key difference between motorized ball valves and many solenoid valves. Most solenoid valves are energized continuously when in a new position, while motorized ball valves expend energy only when changing from open to close, or vice versa.\u003cbr\u003eThe 2 wire auto return model is perfect for situations where the valve needs to be Open in case of power loss. The valve can be energized to open, and left hooked up, with negligible energy used once fully opened. To close, simply shutoff power to the valve. This valve is convenient because it can be operated with a simple on off switch. When on, it will remain open, when turned off (or power is lost for some other reason) the valve automatically closes.\u003c\/p\u003e\n            \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/1.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-bottom:10px; margin-top:20px; color: black;\"\u003e\u003cstrong\u003eAPPLICATION\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n    \u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 1\/2\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n    \u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 1\/2\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n\u003c\/div\u003e\n      \u003cp style=\"font-size: 16px; text-align: left; margin-bottom:10px; margin-top:20px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV00501\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eU.S. Solid\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1\/2\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e2 Wire Auto Return\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eUPVC\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e6 - 8 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eAC 85-265V\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e10 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e2 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1°C to 55°C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e50,000 to 80,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eFull\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\/G\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNormally Open\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1°C to 50°C\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eIP65\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/CE.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP65 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYES. The motorized ball valve is made of lead-free UPVC.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n    \u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP65 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP65. The first digit 6 indicates complete dust - tightness. The second digit 5 means protection against water jets from any direction. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/valve%20model.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material-APP.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/JFMSV-User-manual.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n    \u003cscript\u003e\n\n        \n        const isMobile = window.matchMedia(\"only screen and (max-width: 600px)\").matches;\n        const desktopContent = document.querySelector('.desktop-only');\n        const mobileContent = document.querySelector('.mobile-only');\n\n        if (isMobile) {\n           \n            console.log('');\n           \n            desktopContent.style.display = 'none';\n            mobileContent.style.display = 'block';\n        } else {\n           \n            console.log('');            \n            \n            desktopContent.style.display = 'block';\n            mobileContent.style.display = 'none';\n        }\n    \u003c\/script\u003e\n\n\n\n\u003c\/body\u003e","brand":"U.S. Solid","offers":[{"title":"NPT","offer_id":47642249953535,"sku":"JFMSV00501","price":41.49,"currency_code":"USD","in_stock":true},{"title":"G","offer_id":47642249986303,"sku":"JFMSV00501-G","price":39.99,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/JFMSV00094_1.jpg?v=1765247842"},{"product_id":"3-4-upvc-motorized-ball-valve-85-265v-ac-plastic-electrical-ball-valve-with-full-port-2-wire-auto-return-normally-open","title":"3\/4\" UPVC Motorized Ball Valve - 85-265V AC Plastic Electrical Ball Valve with Full Port, 2 Wire Auto Return, Normally Open","description":"\u003cbody\u003e \n\n\n    \u003cstyle\u003e\n        @media only screen and (max-width: 600px) {\n        }\n    \u003c\/style\u003e\n\n\n    \u003cdiv class=\"desktop-only\"\u003e\n        \n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; line-height: 26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 10px; color: black; font-family: Arial;\"\u003eMotorized ball valves are a vital piece of equipment in numerous applications. This model opens and closes in 6-8 seconds, and remains in its new position while expending almost no energy. This is a key difference between motorized ball valves and many solenoid valves. Most solenoid valves are energized continuously when in a new position, while motorized ball valves expend energy only when changing from open to close, or vice versa.\u003cbr\u003eThe 2 wire auto return model is perfect for situations where the valve needs to be closed in case of power loss. The valve can be energized to open, and left hooked up, with negligible energy used once fully opened. To close, simply shutoff power to the valve. This valve is convenient because it can be operated with a simple on off switch. When on, it will remain open, when turned off (or power is lost for some other reason) the valve automatically closes.\u003c\/p\u003e\n        \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/1.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n             \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n    \u003ctable style=\"border-collapse: collapse;\n                  border: 0px;\n                  width: 100%;\n                  font-family: Arial;\n                  overflow-x: auto;\n                  background-color: #FFFFFF;\"\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"width: 100%;text-align: left;\n                       padding: 0px;\n                       font-size: 16px;\n                       border: 0;\n                       background-color: #FFFFFF;\"\u003e\n                \u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 3\/4\" style=\"width: 100%;height: 100%;\"\u003e\n            \u003c\/td\u003e\n            \u003ctd style=\"width: 100%;text-align: left;\n                       padding: 0px;\n                       font-size: 16px;\n                       border: 0;\n                       background-color: #FFFFFF;\"\u003e\n                \u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 3\/4\" style=\"width: 100%;height: 100%;\"\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/table\u003e\n\u003c\/div\u003e\n          \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e \n \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV00502\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eU.S. Solid\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e3\/4\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e2 Wire Auto Return\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eUPVC\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e6 - 8 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eAC 85-265V\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e10 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e2 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1°C to 55°C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e50,000 to 80,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eFull\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\/G\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNormally Open\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1°C to 50°C\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eIP65\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/CE.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP65 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYES. The motorized ball valve is made of lead-free UPVC.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n    \u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP65 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP65. The first digit 6 indicates complete dust - tightness. The second digit 5 means protection against water jets from any direction. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/valve%20model.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/JFMSV-User-manual.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n    \u003c\/div\u003e\n    \u003cdiv class=\"mobile-only\"\u003e\n        \n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; line-height:26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 0px; color: black; font-family: Arial;\"\u003eMotorized ball valves are a vital piece of equipment in numerous applications. This model opens and closes in 6-8 seconds, and remains in its new position while expending almost no energy. This is a key difference between motorized ball valves and many solenoid valves. Most solenoid valves are energized continuously when in a new position, while motorized ball valves expend energy only when changing from open to close, or vice versa.\u003cbr\u003eThe 2 wire auto return model is perfect for situations where the valve needs to be Open in case of power loss. The valve can be energized to open, and left hooked up, with negligible energy used once fully opened. To close, simply shutoff power to the valve. This valve is convenient because it can be operated with a simple on off switch. When on, it will remain open, when turned off (or power is lost for some other reason) the valve automatically closes.\u003c\/p\u003e\n            \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/1.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-bottom:10px; margin-top:20px; color: black;\"\u003e\u003cstrong\u003eAPPLICATION\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n    \u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 3\/4\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n    \u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 3\/4\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n\u003c\/div\u003e\n      \u003cp style=\"font-size: 16px; text-align: left; margin-bottom:10px; margin-top:20px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV00502\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eU.S. Solid\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e3\/4\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e2 Wire Auto Return\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eUPVC\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e6 - 8 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eAC 85-265V\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e10 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e2 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1°C to 55°C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e50,000 to 80,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eFull\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\/G\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNormally Open\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1°C to 50°C\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eIP65\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/CE.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP65 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYES. The motorized ball valve is made of lead-free UPVC.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n    \u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP65 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP65. The first digit 6 indicates complete dust - tightness. The second digit 5 means protection against water jets from any direction. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/valve%20model.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material-APP.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/JFMSV-User-manual.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n    \u003cscript\u003e\n\n        const isMobile = window.matchMedia(\"only screen and (max-width: 600px)\").matches;\n        const desktopContent = document.querySelector('.desktop-only');\n        const mobileContent = document.querySelector('.mobile-only');\n\n        if (isMobile) {\n            \n            console.log('');\n            \n            desktopContent.style.display = 'none';\n            mobileContent.style.display = 'block';\n        } else {\n            \n            console.log('');            \n            \n            desktopContent.style.display = 'block';\n            mobileContent.style.display = 'none';\n        }\n    \u003c\/script\u003e\n\n\n\n\u003c\/body\u003e","brand":"U.S. Solid","offers":[{"title":"NPT","offer_id":47642250182911,"sku":"JFMSV00502","price":44.49,"currency_code":"USD","in_stock":true},{"title":"G","offer_id":47642250215679,"sku":"JFMSV00502-G","price":41.89,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/JFMSV00095_1.jpg?v=1765247893"},{"product_id":"1-upvc-motorized-ball-valve-85-265v-ac-plastic-electrical-ball-valve-with-full-port-2-wire-auto-return-normally-open","title":"1\" UPVC Motorized Ball Valve - 85-265V AC Plastic Electrical Ball Valve with Full Port, 2 Wire Auto Return, Normally Open","description":"\u003cbody\u003e \n\n\n    \u003cstyle\u003e\n        @media only screen and (max-width: 600px) {\n        }\n    \u003c\/style\u003e\n\n\n    \u003cdiv class=\"desktop-only\"\u003e\n       \n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; line-height: 26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 10px; color: black; font-family: Arial;\"\u003eMotorized ball valves are a vital piece of equipment in numerous applications. This model opens and closes in 6-8 seconds, and remains in its new position while expending almost no energy. This is a key difference between motorized ball valves and many solenoid valves. Most solenoid valves are energized continuously when in a new position, while motorized ball valves expend energy only when changing from open to close, or vice versa.\u003cbr\u003eThe 2 wire auto return model is perfect for situations where the valve needs to be closed in case of power loss. The valve can be energized to open, and left hooked up, with negligible energy used once fully opened. To close, simply shutoff power to the valve. This valve is convenient because it can be operated with a simple on off switch. When on, it will remain open, when turned off (or power is lost for some other reason) the valve automatically closes.\u003c\/p\u003e\n        \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/1.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n             \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n    \u003ctable style=\"border-collapse: collapse;\n                  border: 0px;\n                  width: 100%;\n                  font-family: Arial;\n                  overflow-x: auto;\n                  background-color: #FFFFFF;\"\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"width: 100%;text-align: left;\n                       padding: 0px;\n                       font-size: 16px;\n                       border: 0;\n                       background-color: #FFFFFF;\"\u003e\n                \u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 1\" style=\"width: 100%;height: 100%;\"\u003e\n            \u003c\/td\u003e\n            \u003ctd style=\"width: 100%;text-align: left;\n                       padding: 0px;\n                       font-size: 16px;\n                       border: 0;\n                       background-color: #FFFFFF;\"\u003e\n                \u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 1\" style=\"width: 100%;height: 100%;\"\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/table\u003e\n\u003c\/div\u003e\n          \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e \n \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV00503\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eU.S. Solid\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e2 Wire Auto Return\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eUPVC\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e6 - 8 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eAC 85-265V\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e10 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e2 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1°C to 55°C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e50,000 to 80,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eFull\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\/G\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNormally Open\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1°C to 50°C\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eIP65\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/CE.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP65 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYES. The motorized ball valve is made of lead-free UPVC.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n    \u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP65 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP65. The first digit 6 indicates complete dust - tightness. The second digit 5 means protection against water jets from any direction. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/valve%20model.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/JFMSV-User-manual.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n    \u003c\/div\u003e\n    \u003cdiv class=\"mobile-only\"\u003e\n        \u003c!--  --\u003e\n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; line-height:26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 0px; color: black; font-family: Arial;\"\u003eMotorized ball valves are a vital piece of equipment in numerous applications. This model opens and closes in 6-8 seconds, and remains in its new position while expending almost no energy. This is a key difference between motorized ball valves and many solenoid valves. Most solenoid valves are energized continuously when in a new position, while motorized ball valves expend energy only when changing from open to close, or vice versa.\u003cbr\u003eThe 2 wire auto return model is perfect for situations where the valve needs to be Open in case of power loss. The valve can be energized to open, and left hooked up, with negligible energy used once fully opened. To close, simply shutoff power to the valve. This valve is convenient because it can be operated with a simple on off switch. When on, it will remain open, when turned off (or power is lost for some other reason) the valve automatically closes.\u003c\/p\u003e\n            \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/1.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-bottom:10px; margin-top:20px; color: black;\"\u003e\u003cstrong\u003eAPPLICATION\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n    \u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 1\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n    \u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 1\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n\u003c\/div\u003e\n      \u003cp style=\"font-size: 16px; text-align: left; margin-bottom:10px; margin-top:20px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV00503\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eU.S. Solid\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e2 Wire Auto Return\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eUPVC\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e6 - 8 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eAC 85-265V\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e10 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e2 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1°C to 55°C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e50,000 to 80,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eFull\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\/G\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNormally Open\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1°C to 50°C\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eIP65\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/CE.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP65 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYES. The motorized ball valve is made of lead-free UPVC.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n    \u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP65 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP65. The first digit 6 indicates complete dust - tightness. The second digit 5 means protection against water jets from any direction. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/valve%20model.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material-APP.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/JFMSV-User-manual.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n    \u003cscript\u003e\n\n        \/\/ (User Agent)\n        const isMobile = window.matchMedia(\"only screen and (max-width: 600px)\").matches;\n        const desktopContent = document.querySelector('.desktop-only');\n        const mobileContent = document.querySelector('.mobile-only');\n\n        if (isMobile) {\n            \/\/ \n            console.log('');\n            \/\/ ，\n            desktopContent.style.display = 'none';\n            mobileContent.style.display = 'block';\n        } else {\n            \/\/ \n            console.log('');            \n            \/\/ ，\n            desktopContent.style.display = 'block';\n            mobileContent.style.display = 'none';\n        }\n    \u003c\/script\u003e\n\n\n\n\u003c\/body\u003e","brand":"U.S. Solid","offers":[{"title":"NPT","offer_id":47642253361407,"sku":"JFMSV00503","price":47.49,"currency_code":"USD","in_stock":true},{"title":"G","offer_id":47642253394175,"sku":"JFMSV00503-G","price":45.49,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/JFMSV00096_1.jpg?v=1765247933"},{"product_id":"1-1-4-double-union-upvc-motorized-ball-valve-dc-24v-5-wire-with-signal-feedback-auto-return-normally-closed-manual-override-epdm-seal","title":"1-1\/4\" Double Union UPVC Motorized Ball Valve - DC 24V, 5-Wire with Signal Feedback, Auto Return, Normally Closed \u0026 Manual Override, EPDM Seal","description":"\u003ch2 data-slate-node=\"element\"\u003e\u003cstrong\u003eIntroduction\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-slate-leaf=\"true\" data-sent-id=\"VMd4PNE2Je\" data-para-id=\"0\" class=\"\"\u003e\u003cspan data-slate-string=\"true\"\u003e\u003cspan data-slate-fragment=\"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\"\u003eOur electric UPVC ball valve series has been upgraded to include three larger sizes: 1-1\/4\", 1-1\/2\", and 2\". These larger valves feature a unique \u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eUS standard socket end\u003c\/strong\u003e\u003c\/span\u003e \u0026amp; \u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003edouble union connection\u003c\/span\u003e\u003c\/strong\u003e—enabling exceptional ease of installation and maintenance with a simple solvent cement bond, \u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eunlike\u003c\/strong\u003e\u003c\/span\u003e threaded NPT or G connections. For other connection standards, please contact our customer service.\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-slate-leaf=\"true\" data-sent-id=\"VMd4PNE2Je\" data-para-id=\"0\" class=\"\"\u003e\u003cspan data-slate-string=\"true\"\u003e\u003cspan data-slate-fragment=\"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\"\u003eThese valves feature a \u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003e5-wire\u003c\/span\u003e\u003c\/strong\u003e configuration for enhanced control and monitoring, yet remain in a \u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003enormally-closed\u003c\/strong\u003e\u003c\/span\u003e (NC) position. They utilize two wires for the power supply and three dedicated wires \u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003efor signal feedback only\u003c\/strong\u003e\u003c\/span\u003e. Unlike the 2-wire model, this configuration provides two-way position signaling (Open\/Closed) to your control system for real-time status monitoring. For safety, they automatically close (\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eauto-return\u003c\/strong\u003e\u003c\/span\u003e) if power is lost. A manual override is also included for essential operation during power outages. All valves utilize EPDM seals for reliable, long-term performance.\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-slate-leaf=\"true\" data-sent-id=\"VMd4PNE2Je\" data-para-id=\"0\" class=\"\"\u003e\u003cspan data-slate-string=\"true\"\u003e\u003cspan data-slate-fragment=\"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\"\u003e\u003cspan class=\"\" data-para-id=\"1\" data-sent-id=\"VAJ2GDn4Kz\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-fragment=\"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\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eNOTE:\u003c\/strong\u003e\u003c\/span\u003e This auto-return ball valve requires a min. power-on duration of 60 seconds (≥60s) . This step is mandatory on first commissioning or after prolonged power cut to ensure reliable auto-reset performance.\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-slate-leaf=\"true\" data-sent-id=\"VMd4PNE2Je\" data-para-id=\"0\" class=\"\"\u003e\u003cspan data-slate-string=\"true\"\u003e\u003cspan data-slate-fragment=\"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\"\u003e\u003cspan class=\"\" data-para-id=\"1\" data-sent-id=\"VAJ2GDn4Kz\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-fragment=\"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\"\u003e\u003cspan\u003eTo learn how to use this product, please refer to the\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003e\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/Manual-%20USS-UPVC.pdf\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003euser manual\u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e.\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\n\u003ch2 data-slate-node=\"element\"\u003e\u003cstrong\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-slate-leaf=\"true\" data-sent-id=\"BP90d2vEme\" data-para-id=\"0\" class=\"\"\u003e\u003cspan data-slate-string=\"true\"\u003eSpecifications\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-slate-leaf=\"true\" data-sent-id=\"Bw2DL98jjz\" data-para-id=\"1\" class=\"\"\u003e\u003cspan data-slate-string=\"true\"\u003eModel: USS-MSV470\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-slate-leaf=\"true\" data-sent-id=\"z9ajXPEDJz\" data-para-id=\"2\" class=\"\"\u003e\u003cspan data-slate-string=\"true\"\u003eSize: 1-1\/4\" \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003eConnection: Union \u0026amp;amp; Socket End\u003cbr\u003eSocket Inside Diameter: 42.2mm\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-slate-leaf=\"true\" data-sent-id=\"zrZan5bjLz\" data-para-id=\"5\"\u003e\u003cspan data-slate-string=\"true\"\u003eMaterial: UPVC\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-slate-leaf=\"true\" data-sent-id=\"BZRONq4p5B\" data-para-id=\"6\" class=\"\"\u003e\u003cspan data-slate-string=\"true\"\u003eNormal Position: Normally Closed\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-slate-leaf=\"true\" data-sent-id=\"zlxm27rW1z\" data-para-id=\"7\" class=\"\"\u003e\u003cspan data-slate-string=\"true\"\u003eWorking Voltage: DC 24V\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-slate-leaf=\"true\" data-sent-id=\"BD2jakZR0V\" data-para-id=\"8\" class=\"\"\u003e\u003cspan data-slate-string=\"true\"\u003eMax Power: 36W\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-slate-leaf=\"true\" data-sent-id=\"eLL276pXye\" data-para-id=\"9\" class=\"\"\u003e\u003cspan data-slate-string=\"true\"\u003eMax Torque: 20 N·m\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-slate-leaf=\"true\" data-sent-id=\"Vdompj0KRe\" data-para-id=\"10\" class=\"\"\u003e\u003cspan data-slate-string=\"true\"\u003eMax. Pressure: 232 psi\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\n\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-slate-leaf=\"true\" data-sent-id=\"ebomx1EKpV\" data-para-id=\"11\" class=\"\"\u003e\u003cspan data-slate-string=\"true\"\u003eMedium Temp: 33.8\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-slate-leaf=\"true\" data-sent-id=\"BP90d2vEZe\" data-para-id=\"11\"\u003e\u003cspan data-slate-string=\"true\"\u003e℉ \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-slate-leaf=\"true\" data-sent-id=\"VQaxZEjJ9V\" data-para-id=\"11\"\u003e\u003cspan data-slate-string=\"true\"\u003eto 104\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-slate-leaf=\"true\" data-sent-id=\"Vpgw96Ljre\" data-para-id=\"11\"\u003e\u003cspan data-slate-string=\"true\"\u003e℉\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-slate-leaf=\"true\" data-sent-id=\"VW6NOZM1Ge\" data-para-id=\"12\" class=\"\"\u003e\u003cspan data-slate-string=\"true\"\u003eIP Rating: IP65\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-slate-leaf=\"true\" data-sent-id=\"B89jkb2lpe\" data-para-id=\"13\" class=\"\"\u003e\u003cspan data-slate-string=\"true\"\u003eLife Expectancy: 20,000Cycles\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-slate-leaf=\"true\" data-sent-id=\"V1dK9g4RWe\" data-para-id=\"14\"\u003e\u003cspan data-slate-string=\"true\"\u003eClose\/Open Time: 10-12s\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-slate-leaf=\"true\" data-sent-id=\"Bv2ldwWjPB\" data-para-id=\"15\" class=\"\"\u003e\u003cspan data-slate-string=\"true\"\u003eWiring: 5 wire,auto return, with signal feedback\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-slate-leaf=\"true\" data-sent-id=\"ejq2ZMajdB\" data-para-id=\"16\" class=\"\"\u003e\u003cspan data-slate-string=\"true\"\u003eManual Function: Yes\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-slate-leaf=\"true\" data-sent-id=\"VNEOo5821e\" data-para-id=\"17\" class=\"\"\u003e\u003cspan data-slate-string=\"true\"\u003eSignal feedback function: Yes\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\" data-slate-fragment=\"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\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-slate-leaf=\"true\" data-sent-id=\"zn9m4AljMV\" data-para-id=\"18\"\u003e\u003cspan data-slate-string=\"true\"\u003eSeal: EPDM\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"U.S. Solid","offers":[{"title":"Default Title","offer_id":47743849890047,"sku":"JFMSV00470","price":161.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/1_e994c5be-5ae2-4c5a-ba29-8d05f9297e7b.jpg?v=1758694453"},{"product_id":"1-1-2-double-union-upvc-motorized-ball-valve-dc-24v-5-wire-with-signal-feedback-auto-return-normally-closed-manual-override-epdm-seal","title":"1-1\/2\" Double Union UPVC Motorized Ball Valve - DC 24V, 5-Wire with Signal Feedback, Auto Return, Normally Closed \u0026 Manual Override, EPDM Seal","description":"\u003ch2 data-slate-node=\"element\"\u003e\u003cstrong\u003eIntroduction\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-slate-leaf=\"true\" data-sent-id=\"VMd4PNE2Je\" data-para-id=\"0\" class=\"\"\u003e\u003cspan data-slate-string=\"true\"\u003e\u003cspan data-slate-fragment=\"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\"\u003eOur electric UPVC ball valve series has been upgraded to include three larger sizes: 1-1\/4\", 1-1\/2\", and 2\". These larger valves feature a unique \u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eUS standard socket end\u003c\/strong\u003e\u003c\/span\u003e \u0026amp; \u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003edouble union connection\u003c\/span\u003e\u003c\/strong\u003e—enabling exceptional ease of installation and maintenance with a simple solvent cement bond, \u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eunlike\u003c\/strong\u003e\u003c\/span\u003e threaded NPT or G connections. For other connection standards, please contact our customer service.\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-slate-leaf=\"true\" data-sent-id=\"VMd4PNE2Je\" data-para-id=\"0\" class=\"\"\u003e\u003cspan data-slate-string=\"true\"\u003e\u003cspan data-slate-fragment=\"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\"\u003eThese valves feature a \u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003e5-wire\u003c\/span\u003e\u003c\/strong\u003e configuration for enhanced control and monitoring, yet remain in a \u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003enormally-closed\u003c\/strong\u003e\u003c\/span\u003e (NC) position. They utilize two wires for the power supply and three dedicated wires \u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003efor signal feedback only\u003c\/strong\u003e\u003c\/span\u003e. Unlike the 2-wire model, this configuration provides two-way position signaling (Open\/Closed) to your control system for real-time status monitoring. For safety, they automatically close (\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eauto-return\u003c\/strong\u003e\u003c\/span\u003e) if power is lost. A manual override is also included for essential operation during power outages. All valves utilize EPDM seals for reliable, long-term performance.\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-slate-leaf=\"true\" data-sent-id=\"VMd4PNE2Je\" data-para-id=\"0\" class=\"\"\u003e\u003cspan data-slate-string=\"true\"\u003e\u003cspan data-slate-fragment=\"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\"\u003e\u003cspan data-slate-leaf=\"true\" data-sent-id=\"VAJ2GDn4Kz\" data-para-id=\"1\" class=\"\"\u003e\u003cspan data-slate-fragment=\"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\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eNOTE:\u003c\/strong\u003e\u003c\/span\u003e This auto-return ball valve requires a min. power-on duration of 60 seconds (≥60s) . This step is mandatory on first commissioning or after prolonged power cut to ensure reliable auto-reset performance.\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-slate-leaf=\"true\" data-sent-id=\"VMd4PNE2Je\" data-para-id=\"0\" class=\"\"\u003e\u003cspan data-slate-string=\"true\"\u003e\u003cspan data-slate-fragment=\"JTVCJTdCJTIydHlwZSUyMiUzQSUyMnBhcmFncmFwaCUyMiUyQyUyMmNoaWxkcmVuJTIyJTNBJTVCJTdCJTIyaWQlMjIlM0ElMjJwa0FFZ1dsdncyJTIyJTJDJTIycGFyYUlkeCUyMiUzQTAlMkMlMjJzcmMlMjIlM0ElMjJPdXIlMjBlbGVjdHJpYyUyMFVQVkMlMjBiYWxsJTIwdmFsdmUlMjBzZXJpZXMlMjBoYXMlMjBiZWVuJTIwdXBncmFkZWQlMjB0byUyMGluY2x1ZGUlMjB0aHJlZSUyMGxhcmdlciUyMHNpemVzJTNBJTIwMS0xJTJGNCU1QyUyMiUyQyUyMDEtMSUyRjIlNUMlMjIlMkMlMjBhbmQlMjAyJTVDJTIyLiUyMFRoZXNlJTIwbGFyZ2VyJTIwdmFsdmVzJTIwZmVhdHVyZSUyMGElMjB1bmlxdWUlMjBVUyUyMHN0YW5kYXJkJTIwc29ja2V0JTIwZW5kJTIwJTI2JTIwZG91YmxlJTIwdW5pb24lMjBjb25uZWN0aW9uJUUyJTgwJTk0ZW5hYmxpbmclMjBleGNlcHRpb25hbCUyMGVhc2UlMjBvZiUyMGluc3RhbGxhdGlvbiUyMGFuZCUyMG1haW50ZW5hbmNlJTIwd2l0aCUyMGElMjBzaW1wbGUlMjBzb2x2ZW50JTIwY2VtZW50JTIwYm9uZCUyQyUyMHVubGlrZSUyMHRocmVhZGVkJTIwTlBUJTIwb3IlMjBHJTIwY29ubmVjdGlvbnMuJTIwRm9yJTIwb3RoZXIlMjBjb25uZWN0aW9uJTIwc3RhbmRhcmRzJTJDJTIwcGxlYXNlJTIwY29udGFjdCUyMG91ciUyMGN1c3RvbWVyJTIwc2VydmljZS4lMjIlMkMlMjJkc3QlMjIlM0ElMjIlRTYlODglOTElRTQlQkIlQUMlRTclOUElODQlRTclOTQlQjUlRTUlOEElQThVUFZDJUU3JTkwJTgzJUU5JTk4JTgwJUU3JUIzJUJCJUU1JTg4JTk3JUU1JUI3JUIyJUU3JUJCJThGJUU1JThEJTg3JUU3JUJBJUE3JUVGJUJDJThDJUU1JThDJTg1JUU2JThCJUFDJUU0JUI4JTg5JUU3JUE3JThEJUU2JTlCJUI0JUU1JUE0JUE3JUU3JTlBJTg0JUU1JUIwJUJBJUU1JUFGJUI4JUVGJUJDJTlBMS0xJTJGNCVFOCU4QiVCMSVFNSVBRiVCOCVFMyU4MCU4MTEtMSUyRjIlRTglOEIlQjElRTUlQUYlQjglRTUlOTIlOEMyJUU4JThCJUIxJUU1JUFGJUI4JUUzJTgwJTgyJUU4JUJGJTk5JUU0JUJBJTlCJUU2JTlCJUI0JUU1JUE0JUE3JUU3JTlBJTg0JUU5JTk4JTgwJUU5JTk3JUE4JUU1JTg1JUI3JUU2JTlDJTg5JUU3JThCJUFDJUU3JTg5JUI5JUU3JTlBJTg0JUU3JUJFJThFJUU1JTlCJUJEJUU2JUEwJTg3JUU1JTg3JTg2JUU2JTg5JUJGJUU2JThGJTkyJUU3JUFCJUFGJUU1JTkyJThDJUU1JThGJThDJUU4JTgxJTk0JUU2JThFJUE1JUU1JUE0JUI0JUU4JUJGJTlFJUU2JThFJUE1JUVGJUJDJThDJUU0JUI4JThFJUU4JTlFJUJBJUU3JUJBJUI5TlBUJUU2JTg4JTk2RyVFOCVCRiU5RSVFNiU4RSVBNSVFNCVCOCU4RCVFNSU5MCU4QyVFRiVCQyU4QyVFOSU4MCU5QSVFOCVCRiU4NyVFNyVBRSU4MCVFNSU4RCU5NSVFNyU5QSU4NCVFNiVCQSVCNiVFNSU4OSU4MiVFNyVCMiU5OCVFNSU5MCU4OCVFNSU4OSU4MiVFNyVCMiU5OCVFNSU5MCU4OCVFRiVCQyU4QyVFNSU4RiVBRiVFNCVCQiVBNSVFOSU5RCU5RSVFNSVCOCVCOCVFNSVBRSVCOSVFNiU5OCU5MyVFNSU5QyVCMCVFNSVBRSU4OSVFOCVBMyU4NSVFNSU5MiU4QyVFNyVCQiVCNCVFNiU4QSVBNCVFMyU4MCU4MiVFNiU5QyU4OSVFNSU4NSVCMyVFNSU4NSVCNiVFNCVCQiU5NiVFOCVCRiU5RSVFNiU4RSVBNSVFNiVBMCU4NyVFNSU4NyU4NiVFRiVCQyU4QyVFOCVBRiVCNyVFOCU4MSU5NCVFNyVCMyVCQiVFNiU4OCU5MSVFNCVCQiVBQyVFNyU5QSU4NCVFNSVBRSVBMiVFNiU4OCVCNyVFNiU5QyU4RCVFNSU4QSVBMSVFMyU4MCU4MiUyMiUyQyUyMm1ldGFkYXRhJTIyJTNBJTIyJTIyJTJDJTIybWF0Y2hlcyUyMiUzQW51bGwlMkMlMjJ0cmFuc2xhdGVkQnklMjIlM0FudWxsJTJDJTIybWV0YURhdGElMjIlM0ElNUIlNUQlMkMlMjJ0ZXh0JTIyJTNBJTIyT3VyJTIwZWxlY3RyaWMlMjBVUFZDJTIwYmFsbCUyMHZhbHZlJTIwc2VyaWVzJTIwaGFzJTIwYmVlbiUyMHVwZ3JhZGVkJTIwdG8lMjBpbmNsdWRlJTIwdGhyZWUlMjBsYXJnZXIlMjBzaXplcyUzQSUyMDEtMSUyRjQlNUMlMjIlMkMlMjAxLTElMkYyJTVDJTIyJTJDJTIwYW5kJTIwMiU1QyUyMi4lMjBUaGVzZSUyMGxhcmdlciUyMHZhbHZlcyUyMGZlYXR1cmUlMjBhJTIwdW5pcXVlJTIwVVMlMjBzdGFuZGFyZCUyMHNvY2tldCUyMGVuZCUyMCUyNiUyMGRvdWJsZSUyMHVuaW9uJTIwY29ubmVjdGlvbiVFMiU4MCU5NGVuYWJsaW5nJTIwZXhjZXB0aW9uYWwlMjBlYXNlJTIwb2YlMjBpbnN0YWxsYXRpb24lMjBhbmQlMjBtYWludGVuYW5jZSUyMHdpdGglMjBhJTIwc2ltcGxlJTIwc29sdmVudCUyMGNlbWVudCUyMGJvbmQlMkMlMjB1bmxpa2UlMjB0aHJlYWRlZCUyME5QVCUyMG9yJTIwRyUyMGNvbm5lY3Rpb25zLiUyMEZvciUyMG90aGVyJTIwY29ubmVjdGlvbiUyMHN0YW5kYXJkcyUyQyUyMHBsZWFzZSUyMGNvbnRhY3QlMjBvdXIlMjBjdXN0b21lciUyMHNlcnZpY2UuJTIyJTdEJTVEJTdEJTVE\"\u003e\u003cspan data-slate-leaf=\"true\" data-sent-id=\"VAJ2GDn4Kz\" data-para-id=\"1\" class=\"\"\u003e\u003cspan data-slate-fragment=\"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\"\u003e\u003cspan\u003eTo learn how to use this product, please refer to the\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003e\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/Manual-%20USS-UPVC.pdf\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003euser manual\u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e.\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\n\u003ch2 data-slate-node=\"element\"\u003e\u003cstrong\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan class=\"\" data-para-id=\"0\" data-sent-id=\"BP90d2vEme\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-string=\"true\"\u003eSpecifications\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan class=\"\" data-para-id=\"1\" data-sent-id=\"Bw2DL98jjz\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-string=\"true\"\u003eModel: USS-MSV471\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan class=\"\" data-para-id=\"2\" data-sent-id=\"z9ajXPEDJz\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-string=\"true\"\u003eSize: 1-1\/2\" \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003eConnection: Union \u0026amp;amp; Socket End\u003cbr\u003eSocket Inside Diameter: 48.3mm\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-para-id=\"5\" data-sent-id=\"zrZan5bjLz\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-string=\"true\"\u003eMaterial: UPVC\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan class=\"\" data-para-id=\"6\" data-sent-id=\"BZRONq4p5B\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-string=\"true\"\u003eNormal Position: Normally Closed\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan class=\"\" data-para-id=\"7\" data-sent-id=\"zlxm27rW1z\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-string=\"true\"\u003eWorking Voltage: DC 24V\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan class=\"\" data-para-id=\"8\" data-sent-id=\"BD2jakZR0V\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-string=\"true\"\u003eMax Power: 36W\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan class=\"\" data-para-id=\"9\" data-sent-id=\"eLL276pXye\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-string=\"true\"\u003eMax Torque: 20 N·m\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan class=\"\" data-para-id=\"10\" data-sent-id=\"Vdompj0KRe\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-string=\"true\"\u003eMax. Pressure: 232 psi\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\n\u003cspan data-slate-node=\"text\"\u003e\u003cspan class=\"\" data-para-id=\"11\" data-sent-id=\"ebomx1EKpV\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-string=\"true\"\u003eMedium Temp: 33.8\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-para-id=\"11\" data-sent-id=\"BP90d2vEZe\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-string=\"true\"\u003e℉ \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-para-id=\"11\" data-sent-id=\"VQaxZEjJ9V\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-string=\"true\"\u003eto 104\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-para-id=\"11\" data-sent-id=\"Vpgw96Ljre\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-string=\"true\"\u003e℉\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan class=\"\" data-para-id=\"12\" data-sent-id=\"VW6NOZM1Ge\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-string=\"true\"\u003eIP Rating: IP65\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan class=\"\" data-para-id=\"13\" data-sent-id=\"B89jkb2lpe\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-string=\"true\"\u003eLife Expectancy: 20,000Cycles\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-para-id=\"14\" data-sent-id=\"V1dK9g4RWe\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-string=\"true\"\u003eClose\/Open Time: 10-12s\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan class=\"\" data-para-id=\"15\" data-sent-id=\"Bv2ldwWjPB\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-string=\"true\"\u003eWiring: 5 wire,auto return, with signal feedback\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan class=\"\" data-para-id=\"16\" data-sent-id=\"ejq2ZMajdB\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-string=\"true\"\u003eManual Function: Yes\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan class=\"\" data-para-id=\"17\" data-sent-id=\"VNEOo5821e\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-string=\"true\"\u003eSignal feedback function: Yes\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-fragment=\"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\" data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-para-id=\"18\" data-sent-id=\"zn9m4AljMV\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-string=\"true\"\u003eSeal: EPDM\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"U.S. Solid","offers":[{"title":"Default Title","offer_id":47743850086655,"sku":"JFMSV00471","price":171.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/2_9c8be148-836c-4030-8810-599b2b24aea6.jpg?v=1758694502"},{"product_id":"2-double-union-upvc-motorized-ball-valve-dc-24v-5-wire-with-signal-feedback-auto-return-normally-closed-manual-override-epdm-seal","title":"2\" Double Union UPVC Motorized Ball Valve - DC 24V, 5-Wire with Signal Feedback, Auto Return, Normally Closed \u0026 Manual Override, EPDM Seal","description":"\u003ch2 data-slate-node=\"element\"\u003e\u003cstrong\u003eIntroduction\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-slate-leaf=\"true\" data-sent-id=\"VMd4PNE2Je\" data-para-id=\"0\" class=\"\"\u003e\u003cspan data-slate-string=\"true\"\u003e\u003cspan data-slate-fragment=\"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\"\u003eOur electric UPVC ball valve series has been upgraded to include three larger sizes: 1-1\/4\", 1-1\/2\", and 2\". These larger valves feature a unique \u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eUS standard socket end\u003c\/strong\u003e\u003c\/span\u003e \u0026amp; \u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003edouble union connection\u003c\/span\u003e\u003c\/strong\u003e—enabling exceptional ease of installation and maintenance with a simple solvent cement bond, \u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eunlike\u003c\/strong\u003e\u003c\/span\u003e threaded NPT or G connections. For other connection standards, please contact our customer service.\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-slate-leaf=\"true\" data-sent-id=\"VMd4PNE2Je\" data-para-id=\"0\" class=\"\"\u003e\u003cspan data-slate-string=\"true\"\u003e\u003cspan data-slate-fragment=\"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\"\u003eThese valves feature a \u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003e5-wire\u003c\/span\u003e\u003c\/strong\u003e configuration for enhanced control and monitoring, yet remain in a \u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003enormally-closed\u003c\/strong\u003e\u003c\/span\u003e (NC) position. They utilize two wires for the power supply and three dedicated wires \u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003efor signal feedback only\u003c\/strong\u003e\u003c\/span\u003e. Unlike the 2-wire model, this configuration provides two-way position signaling (Open\/Closed) to your control system for real-time status monitoring. For safety, they automatically close (\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eauto-return\u003c\/strong\u003e\u003c\/span\u003e) if power is lost. A manual override is also included for essential operation during power outages. All valves utilize EPDM seals for reliable, long-term performance.\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-slate-leaf=\"true\" data-sent-id=\"VMd4PNE2Je\" data-para-id=\"0\" class=\"\"\u003e\u003cspan data-slate-string=\"true\"\u003e\u003cspan data-slate-fragment=\"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\"\u003e\u003cspan class=\"\" data-para-id=\"1\" data-sent-id=\"VAJ2GDn4Kz\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-fragment=\"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\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eNOTE:\u003c\/strong\u003e\u003c\/span\u003e This auto-return ball valve requires a min. power-on duration of 60 seconds (≥60s) . This step is mandatory on first commissioning or after prolonged power cut to ensure reliable auto-reset performance.\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-slate-leaf=\"true\" data-sent-id=\"VMd4PNE2Je\" data-para-id=\"0\" class=\"\"\u003e\u003cspan data-slate-string=\"true\"\u003e\u003cspan data-slate-fragment=\"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\"\u003e\u003cspan class=\"\" data-para-id=\"1\" data-sent-id=\"VAJ2GDn4Kz\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-fragment=\"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\"\u003e\u003cspan\u003eTo learn how to use this product, please refer to the\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003e\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/Manual-%20USS-UPVC.pdf\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003euser manual\u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e.\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\n\u003ch2 data-slate-node=\"element\"\u003e\u003cstrong\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-slate-leaf=\"true\" data-sent-id=\"BP90d2vEme\" data-para-id=\"0\" class=\"\"\u003e\u003cspan data-slate-string=\"true\"\u003eSpecifications\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-slate-leaf=\"true\" data-sent-id=\"Bw2DL98jjz\" data-para-id=\"1\" class=\"\"\u003e\u003cspan data-slate-string=\"true\"\u003eModel: USS-MSV472\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-slate-leaf=\"true\" data-sent-id=\"z9ajXPEDJz\" data-para-id=\"2\" class=\"\"\u003e\u003cspan data-slate-string=\"true\"\u003eSize: 2\" \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003eConnection: Union \u0026amp;amp; Socket End\u003cbr\u003eSocket Inside Diameter: 60.3mm\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-slate-leaf=\"true\" data-sent-id=\"zrZan5bjLz\" data-para-id=\"5\"\u003e\u003cspan data-slate-string=\"true\"\u003eMaterial: UPVC\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-slate-leaf=\"true\" data-sent-id=\"BZRONq4p5B\" data-para-id=\"6\" class=\"\"\u003e\u003cspan data-slate-string=\"true\"\u003eNormal Position: Normally Closed\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-slate-leaf=\"true\" data-sent-id=\"zlxm27rW1z\" data-para-id=\"7\" class=\"\"\u003e\u003cspan data-slate-string=\"true\"\u003eWorking Voltage: DC 24V\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-slate-leaf=\"true\" data-sent-id=\"BD2jakZR0V\" data-para-id=\"8\" class=\"\"\u003e\u003cspan data-slate-string=\"true\"\u003eMax Power: 36W\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-slate-leaf=\"true\" data-sent-id=\"eLL276pXye\" data-para-id=\"9\" class=\"\"\u003e\u003cspan data-slate-string=\"true\"\u003eMax Torque: 20 N·m\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-slate-leaf=\"true\" data-sent-id=\"Vdompj0KRe\" data-para-id=\"10\" class=\"\"\u003e\u003cspan data-slate-string=\"true\"\u003eMax. Pressure: 232 psi\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\n\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-slate-leaf=\"true\" data-sent-id=\"ebomx1EKpV\" data-para-id=\"11\" class=\"\"\u003e\u003cspan data-slate-string=\"true\"\u003eMedium Temp: 33.8\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-slate-leaf=\"true\" data-sent-id=\"BP90d2vEZe\" data-para-id=\"11\"\u003e\u003cspan data-slate-string=\"true\"\u003e℉ \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-slate-leaf=\"true\" data-sent-id=\"VQaxZEjJ9V\" data-para-id=\"11\"\u003e\u003cspan data-slate-string=\"true\"\u003eto 104\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-slate-leaf=\"true\" data-sent-id=\"Vpgw96Ljre\" data-para-id=\"11\"\u003e\u003cspan data-slate-string=\"true\"\u003e℉\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-slate-leaf=\"true\" data-sent-id=\"VW6NOZM1Ge\" data-para-id=\"12\" class=\"\"\u003e\u003cspan data-slate-string=\"true\"\u003eIP Rating: IP65\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-slate-leaf=\"true\" data-sent-id=\"B89jkb2lpe\" data-para-id=\"13\" class=\"\"\u003e\u003cspan data-slate-string=\"true\"\u003eLife Expectancy: 20,000Cycles\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-slate-leaf=\"true\" data-sent-id=\"V1dK9g4RWe\" data-para-id=\"14\"\u003e\u003cspan data-slate-string=\"true\"\u003eClose\/Open Time: 10-12s\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-slate-leaf=\"true\" data-sent-id=\"Bv2ldwWjPB\" data-para-id=\"15\" class=\"\"\u003e\u003cspan data-slate-string=\"true\"\u003eWiring: 5 wire,auto return, with signal feedback\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-slate-leaf=\"true\" data-sent-id=\"ejq2ZMajdB\" data-para-id=\"16\" class=\"\"\u003e\u003cspan data-slate-string=\"true\"\u003eManual Function: Yes\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-slate-leaf=\"true\" data-sent-id=\"VNEOo5821e\" data-para-id=\"17\" class=\"\"\u003e\u003cspan data-slate-string=\"true\"\u003eSignal feedback function: Yes\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\" data-slate-fragment=\"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\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-slate-leaf=\"true\" data-sent-id=\"zn9m4AljMV\" data-para-id=\"18\"\u003e\u003cspan data-slate-string=\"true\"\u003eSeal: EPDM\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"U.S. Solid","offers":[{"title":"Default Title","offer_id":47743850479871,"sku":"JFMSV00472","price":181.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/3_c2e2f334-14b7-4e14-892b-83f625b659fa.jpg?v=1758694547"},{"product_id":"upvc-3-way-motorized-ball-valve-l-type-union-socket-end-2-wire-auto-return-dc-24v-with-manual-override","title":"1\/2\" UPVC 3-Way Motorized Ball Valve (L Type), Union \u0026 Socket End, 2 Wire Auto Return, DC 24V, with Manual Override","description":"\u003ch2 data-slate-node=\"element\"\u003e\u003cstrong\u003eIntroduction\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan class=\"\" data-para-id=\"0\" data-sent-id=\"VMd4PNE2Je\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-string=\"true\"\u003e\u003cspan data-slate-fragment=\"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\"\u003e\u003cspan\u003eThis \u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eUPVC 3-way\u003c\/strong\u003e\u003c\/span\u003e motorized ball valve provides an alternative solution to our standard brass\/stainless steel threaded ball valves currently available. Distinguished from NPT\/G threaded connections, it adopts \u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eAmerican standard socket end \u0026amp; union connection\u003c\/strong\u003e\u003c\/span\u003e, which balances stable sealing performance with the convenience of quick disassembly and maintenance. Equipped with a \u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003e2-wire auto-return\u003c\/strong\u003e\u003c\/span\u003e, the valve switches flow path via power on\/off, with EPDM seals ensuring reliable operation. It is the ideal choice for water treatment, HVAC, and low-pressure industrial fluid handling applications. For other connection standards, please contact our customer service.\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan class=\"\" data-para-id=\"0\" data-sent-id=\"VMd4PNE2Je\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-string=\"true\"\u003e\u003cspan data-slate-fragment=\"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\"\u003e\u003cspan\u003eThis 3-way valve series offers L-type and T-type configurations (2 options for T-type: T1\/T2). Please note the distinction when purchasing (refer to the main images for flow path type details).\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan class=\"\" data-para-id=\"0\" data-sent-id=\"VMd4PNE2Je\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-string=\"true\"\u003e\u003cspan data-slate-fragment=\"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\"\u003e\u003cspan\u003e\u003cspan class=\"\" data-para-id=\"1\" data-sent-id=\"VAJ2GDn4Kz\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-fragment=\"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\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eNOTE:\u003c\/strong\u003e\u003c\/span\u003e This auto-return ball valve requires a min. power-on duration of 60 seconds (≥60s) . This step is mandatory on first commissioning or after prolonged power cut to ensure reliable auto-reset performance.\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\n\u003cspan style=\"display:inline-block;\"\u003eTo learn how to use this product, please refer to the \u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/Manual-%20USS-UPVC-3way.pdf\" target=\"_blank\"\u003euser manual\u003c\/a\u003e.\u003c\/span\u003e\u003ch2 data-slate-node=\"element\"\u003e\u003cstrong\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan class=\"\" data-para-id=\"0\" data-sent-id=\"BP90d2vEme\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-string=\"true\"\u003eSpecifications\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan class=\"\" data-para-id=\"1\" data-sent-id=\"Bw2DL98jjz\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-string=\"true\"\u003e\u003cspan\u003eValve Port Type: 3 Way (L Type)\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan class=\"\" data-para-id=\"1\" data-sent-id=\"Bw2DL98jjz\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-string=\"true\"\u003eModel: USS-MSV601\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan class=\"\" data-para-id=\"2\" data-sent-id=\"z9ajXPEDJz\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-string=\"true\"\u003eSize: 1\/2\" \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003eConnection: Union \u0026amp; Socket End\u003cbr\u003eSocket Inside Diameter: 21.3mm\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-para-id=\"5\" data-sent-id=\"zrZan5bjLz\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-string=\"true\"\u003eMaterial: UPVC\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan class=\"\" data-para-id=\"7\" data-sent-id=\"zlxm27rW1z\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-string=\"true\"\u003eWorking Voltage: DC 24V\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan class=\"\" data-para-id=\"8\" data-sent-id=\"BD2jakZR0V\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-string=\"true\"\u003eMax Power: 36W\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan class=\"\" data-para-id=\"9\" data-sent-id=\"eLL276pXye\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-string=\"true\"\u003eMax Torque: 20 N·m\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan class=\"\" data-para-id=\"10\" data-sent-id=\"Vdompj0KRe\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-string=\"true\"\u003eMax. Pressure: 232 psi\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\n\u003cspan data-slate-node=\"text\"\u003e\u003cspan class=\"\" data-para-id=\"11\" data-sent-id=\"ebomx1EKpV\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-string=\"true\"\u003eMedium Temp: 33.8\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-para-id=\"11\" data-sent-id=\"BP90d2vEZe\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-string=\"true\"\u003e℉ \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-para-id=\"11\" data-sent-id=\"VQaxZEjJ9V\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-string=\"true\"\u003eto 104\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-para-id=\"11\" data-sent-id=\"Vpgw96Ljre\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-string=\"true\"\u003e℉\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan class=\"\" data-para-id=\"12\" data-sent-id=\"VW6NOZM1Ge\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-string=\"true\"\u003eIP Rating: IP65\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan class=\"\" data-para-id=\"13\" data-sent-id=\"B89jkb2lpe\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-string=\"true\"\u003eLife Expectancy: 20,000Cycles\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-para-id=\"14\" data-sent-id=\"V1dK9g4RWe\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-string=\"true\"\u003eClose\/Open Time: 10-12s\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan class=\"\" data-para-id=\"15\" data-sent-id=\"Bv2ldwWjPB\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-string=\"true\"\u003eWiring: 2 wire,auto return\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan class=\"\" data-para-id=\"16\" data-sent-id=\"ejq2ZMajdB\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-string=\"true\"\u003eManual Function: Yes\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan class=\"\" data-para-id=\"17\" data-sent-id=\"VNEOo5821e\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-string=\"true\"\u003eSignal feedback function: No\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-fragment=\"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\" data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-para-id=\"18\" data-sent-id=\"zn9m4AljMV\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-string=\"true\"\u003eSeal: EPDM\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-fragment=\"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\" data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-para-id=\"18\" data-sent-id=\"zn9m4AljMV\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-string=\"true\"\u003e\u003cspan data-slate-fragment=\"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\"\u003e\u003cspan class=\"\" data-para-id=\"0\" data-sent-id=\"VMd4PNE2Je\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-fragment=\"JTVCJTdCJTIydHlwZSUyMiUzQSUyMnBhcmFncmFwaCUyMiUyQyUyMmNoaWxkcmVuJTIyJTNBJTVCJTdCJTIyaWQlMjIlM0ElMjJwa0FFZ1dsdncyJTIyJTJDJTIycGFyYUlkeCUyMiUzQTAlMkMlMjJzcmMlMjIlM0ElMjJPdXIlMjBlbGVjdHJpYyUyMFVQVkMlMjBiYWxsJTIwdmFsdmUlMjBzZXJpZXMlMjBoYXMlMjBiZWVuJTIwdXBncmFkZWQlMjB0byUyMGluY2x1ZGUlMjB0aHJlZSUyMGxhcmdlciUyMHNpemVzJTNBJTIwMS0xJTJGNCU1QyUyMiUyQyUyMDEtMSUyRjIlNUMlMjIlMkMlMjBhbmQlMjAyJTVDJTIyLiUyMFRoZXNlJTIwbGFyZ2VyJTIwdmFsdmVzJTIwZmVhdHVyZSUyMGElMjB1bmlxdWUlMjBVUyUyMHN0YW5kYXJkJTIwc29ja2V0JTIwZW5kJTIwJTI2JTIwZG91YmxlJTIwdW5pb24lMjBjb25uZWN0aW9uJUUyJTgwJTk0ZW5hYmxpbmclMjBleGNlcHRpb25hbCUyMGVhc2UlMjBvZiUyMGluc3RhbGxhdGlvbiUyMGFuZCUyMG1haW50ZW5hbmNlJTIwd2l0aCUyMGElMjBzaW1wbGUlMjBzb2x2ZW50JTIwY2VtZW50JTIwYm9uZCUyQyUyMHVubGlrZSUyMHRocmVhZGVkJTIwTlBUJTIwb3IlMjBHJTIwY29ubmVjdGlvbnMuJTIwRm9yJTIwb3RoZXIlMjBjb25uZWN0aW9uJTIwc3RhbmRhcmRzJTJDJTIwcGxlYXNlJTIwY29udGFjdCUyMG91ciUyMGN1c3RvbWVyJTIwc2VydmljZS4lMjIlMkMlMjJkc3QlMjIlM0ElMjIlRTYlODglOTElRTQlQkIlQUMlRTclOUElODQlRTclOTQlQjUlRTUlOEElQThVUFZDJUU3JTkwJTgzJUU5JTk4JTgwJUU3JUIzJUJCJUU1JTg4JTk3JUU1JUI3JUIyJUU3JUJCJThGJUU1JThEJTg3JUU3JUJBJUE3JUVGJUJDJThDJUU1JThDJTg1JUU2JThCJUFDJUU0JUI4JTg5JUU3JUE3JThEJUU2JTlCJUI0JUU1JUE0JUE3JUU3JTlBJTg0JUU1JUIwJUJBJUU1JUFGJUI4JUVGJUJDJTlBMS0xJTJGNCVFOCU4QiVCMSVFNSVBRiVCOCVFMyU4MCU4MTEtMSUyRjIlRTglOEIlQjElRTUlQUYlQjglRTUlOTIlOEMyJUU4JThCJUIxJUU1JUFGJUI4JUUzJTgwJTgyJUU4JUJGJTk5JUU0JUJBJTlCJUU2JTlCJUI0JUU1JUE0JUE3JUU3JTlBJTg0JUU5JTk4JTgwJUU5JTk3JUE4JUU1JTg1JUI3JUU2JTlDJTg5JUU3JThCJUFDJUU3JTg5JUI5JUU3JTlBJTg0JUU3JUJFJThFJUU1JTlCJUJEJUU2JUEwJTg3JUU1JTg3JTg2JUU2JTg5JUJGJUU2JThGJTkyJUU3JUFCJUFGJUU1JTkyJThDJUU1JThGJThDJUU4JTgxJTk0JUU2JThFJUE1JUU1JUE0JUI0JUU4JUJGJTlFJUU2JThFJUE1JUVGJUJDJThDJUU0JUI4JThFJUU4JTlFJUJBJUU3JUJBJUI5TlBUJUU2JTg4JTk2RyVFOCVCRiU5RSVFNiU4RSVBNSVFNCVCOCU4RCVFNSU5MCU4QyVFRiVCQyU4QyVFOSU4MCU5QSVFOCVCRiU4NyVFNyVBRSU4MCVFNSU4RCU5NSVFNyU5QSU4NCVFNiVCQSVCNiVFNSU4OSU4MiVFNyVCMiU5OCVFNSU5MCU4OCVFNSU4OSU4MiVFNyVCMiU5OCVFNSU5MCU4OCVFRiVCQyU4QyVFNSU4RiVBRiVFNCVCQiVBNSVFOSU5RCU5RSVFNSVCOCVCOCVFNSVBRSVCOSVFNiU5OCU5MyVFNSU5QyVCMCVFNSVBRSU4OSVFOCVBMyU4NSVFNSU5MiU4QyVFNyVCQiVCNCVFNiU4QSVBNCVFMyU4MCU4MiVFNiU5QyU4OSVFNSU4NSVCMyVFNSU4NSVCNiVFNCVCQiU5NiVFOCVCRiU5RSVFNiU4RSVBNSVFNiVBMCU4NyVFNSU4NyU4NiVFRiVCQyU4QyVFOCVBRiVCNyVFOCU4MSU5NCVFNyVCMyVCQiVFNiU4OCU5MSVFNCVCQiVBQyVFNyU5QSU4NCVFNSVBRSVBMiVFNiU4OCVCNyVFNiU5QyU4RCVFNSU4QSVBMSVFMyU4MCU4MiUyMiUyQyUyMm1ldGFkYXRhJTIyJTNBJTIyJTIyJTJDJTIybWF0Y2hlcyUyMiUzQW51bGwlMkMlMjJ0cmFuc2xhdGVkQnklMjIlM0FudWxsJTJDJTIybWV0YURhdGElMjIlM0ElNUIlNUQlMkMlMjJ0ZXh0JTIyJTNBJTIyT3VyJTIwZWxlY3RyaWMlMjBVUFZDJTIwYmFsbCUyMHZhbHZlJTIwc2VyaWVzJTIwaGFzJTIwYmVlbiUyMHVwZ3JhZGVkJTIwdG8lMjBpbmNsdWRlJTIwdGhyZWUlMjBsYXJnZXIlMjBzaXplcyUzQSUyMDEtMSUyRjQlNUMlMjIlMkMlMjAxLTElMkYyJTVDJTIyJTJDJTIwYW5kJTIwMiU1QyUyMi4lMjBUaGVzZSUyMGxhcmdlciUyMHZhbHZlcyUyMGZlYXR1cmUlMjBhJTIwdW5pcXVlJTIwVVMlMjBzdGFuZGFyZCUyMHNvY2tldCUyMGVuZCUyMCUyNiUyMGRvdWJsZSUyMHVuaW9uJTIwY29ubmVjdGlvbiVFMiU4MCU5NGVuYWJsaW5nJTIwZXhjZXB0aW9uYWwlMjBlYXNlJTIwb2YlMjBpbnN0YWxsYXRpb24lMjBhbmQlMjBtYWludGVuYW5jZSUyMHdpdGglMjBhJTIwc2ltcGxlJTIwc29sdmVudCUyMGNlbWVudCUyMGJvbmQlMkMlMjB1bmxpa2UlMjB0aHJlYWRlZCUyME5QVCUyMG9yJTIwRyUyMGNvbm5lY3Rpb25zLiUyMEZvciUyMG90aGVyJTIwY29ubmVjdGlvbiUyMHN0YW5kYXJkcyUyQyUyMHBsZWFzZSUyMGNvbnRhY3QlMjBvdXIlMjBjdXN0b21lciUyMHNlcnZpY2UuJTIyJTdEJTVEJTdEJTVE\"\u003e\u003cspan\u003e\u003cspan class=\"\" data-para-id=\"1\" data-sent-id=\"VAJ2GDn4Kz\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-fragment=\"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\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eNOTE:\u003c\/strong\u003e\u003c\/span\u003e \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eThree-way valves are not categorized as normally open (NO) or normally closed (NC). For 2-wire auto-reset models, resetting means returning to the default passage state under power-off conditions.\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- TERMINOLOGY_UPDATED: flow direction → flow path - 2026-03-11 10:22:02 --\u003e","brand":"U.S. Solid","offers":[{"title":"Default Title","offer_id":47870941004031,"sku":"JFMSV00601","price":257.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/1_c10be6d7-b18f-4915-a3f4-b1191fc2533c.jpg?v=1765848983"},{"product_id":"upvc-3-way-motorized-ball-valve-t1-type-union-socket-end-2-wire-auto-return-dc-24v-with-manual-override","title":"1\/2\" UPVC 3-Way Motorized Ball Valve (T1 Type), Union \u0026 Socket End, 2 Wire Auto Return, DC 24V, with Manual Override","description":"\u003ch2 data-slate-node=\"element\"\u003e\u003cstrong\u003eIntroduction\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan class=\"\" data-para-id=\"0\" data-sent-id=\"VMd4PNE2Je\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-string=\"true\"\u003e\u003cspan data-slate-fragment=\"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\"\u003e\u003cspan\u003eThis \u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eUPVC 3-way\u003c\/strong\u003e\u003c\/span\u003e motorized ball valve provides an alternative solution to our standard brass\/stainless steel threaded ball valves currently available. Distinguished from NPT\/G threaded connections, it adopts \u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eAmerican standard socket end \u0026amp; union connection\u003c\/strong\u003e\u003c\/span\u003e, which balances stable sealing performance with the convenience of quick disassembly and maintenance. Equipped with a \u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003e2-wire auto-return\u003c\/strong\u003e\u003c\/span\u003e, the valve switches flow path via power on\/off, with EPDM seals ensuring reliable operation. It is the ideal choice for water treatment, HVAC, and low-pressure industrial fluid handling applications. For other connection standards, please contact our customer service.\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan class=\"\" data-para-id=\"0\" data-sent-id=\"VMd4PNE2Je\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-string=\"true\"\u003e\u003cspan data-slate-fragment=\"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\"\u003e\u003cspan\u003eThis 3-way valve series offers L-type and T-type configurations (2 options for T-type: T1\/T2). Please note the distinction when purchasing (refer to the main images for flow path type details).\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan class=\"\" data-para-id=\"0\" data-sent-id=\"VMd4PNE2Je\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-string=\"true\"\u003e\u003cspan data-slate-fragment=\"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\"\u003e\u003cspan\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003eNOTE:\u003c\/span\u003e\u003c\/strong\u003e This auto-return ball valve requires a min. power-on duration of 60 seconds (≥60s) . This step is mandatory on first commissioning or after prolonged power cut to ensure reliable auto-reset performance.\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\n\u003cspan style=\"display:inline-block;\"\u003eTo learn how to use this product, please refer to the \u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/Manual-%20USS-UPVC-3way.pdf\" target=\"_blank\"\u003euser manual\u003c\/a\u003e.\u003c\/span\u003e\u003ch2 data-slate-node=\"element\"\u003e\u003cstrong\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan class=\"\" data-para-id=\"0\" data-sent-id=\"BP90d2vEme\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-string=\"true\"\u003eSpecifications\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan class=\"\" data-para-id=\"1\" data-sent-id=\"Bw2DL98jjz\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-string=\"true\"\u003e\u003cspan\u003eValve Port Type: 3 Way (T1 Type)\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan class=\"\" data-para-id=\"1\" data-sent-id=\"Bw2DL98jjz\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-string=\"true\"\u003eModel: USS-MSV606\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan class=\"\" data-para-id=\"2\" data-sent-id=\"z9ajXPEDJz\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-string=\"true\"\u003eSize: 1\/2\" \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003eConnection: Union \u0026amp; Socket End\u003cbr\u003eSocket Inside Diameter: 21.3mm\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-para-id=\"5\" data-sent-id=\"zrZan5bjLz\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-string=\"true\"\u003eMaterial: UPVC\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan class=\"\" data-para-id=\"7\" data-sent-id=\"zlxm27rW1z\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-string=\"true\"\u003eWorking Voltage: DC 24V\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan class=\"\" data-para-id=\"8\" data-sent-id=\"BD2jakZR0V\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-string=\"true\"\u003eMax Power: 36W\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan class=\"\" data-para-id=\"9\" data-sent-id=\"eLL276pXye\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-string=\"true\"\u003eMax Torque: 20 N·m\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan class=\"\" data-para-id=\"10\" data-sent-id=\"Vdompj0KRe\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-string=\"true\"\u003eMax. Pressure: 232 psi\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\n\u003cspan data-slate-node=\"text\"\u003e\u003cspan class=\"\" data-para-id=\"11\" data-sent-id=\"ebomx1EKpV\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-string=\"true\"\u003eMedium Temp: 33.8\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-para-id=\"11\" data-sent-id=\"BP90d2vEZe\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-string=\"true\"\u003e℉ \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-para-id=\"11\" data-sent-id=\"VQaxZEjJ9V\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-string=\"true\"\u003eto 104\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-para-id=\"11\" data-sent-id=\"Vpgw96Ljre\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-string=\"true\"\u003e℉\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan class=\"\" data-para-id=\"12\" data-sent-id=\"VW6NOZM1Ge\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-string=\"true\"\u003eIP Rating: IP65\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan class=\"\" data-para-id=\"13\" data-sent-id=\"B89jkb2lpe\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-string=\"true\"\u003eLife Expectancy: 20,000Cycles\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-para-id=\"14\" data-sent-id=\"V1dK9g4RWe\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-string=\"true\"\u003eClose\/Open Time: 10-12s\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan class=\"\" data-para-id=\"15\" data-sent-id=\"Bv2ldwWjPB\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-string=\"true\"\u003eWiring: 2 wire,auto return\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan class=\"\" data-para-id=\"16\" data-sent-id=\"ejq2ZMajdB\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-string=\"true\"\u003eManual Function: Yes\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan class=\"\" data-para-id=\"17\" data-sent-id=\"VNEOo5821e\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-string=\"true\"\u003eSignal feedback function: No\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-fragment=\"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\" data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-para-id=\"18\" data-sent-id=\"zn9m4AljMV\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-string=\"true\"\u003eSeal: EPDM\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-fragment=\"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\" data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-para-id=\"18\" data-sent-id=\"zn9m4AljMV\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-string=\"true\"\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003eNOTE:\u003c\/span\u003e\u003c\/strong\u003e Three-way valves are not categorized as normally open (NO) or normally closed (NC). For 2-wire auto-reset models, resetting means returning to the default passage state under power-off conditions.\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- TERMINOLOGY_UPDATED: flow direction → flow path - 2026-03-11 10:25:58 --\u003e","brand":"U.S. Solid","offers":[{"title":"Default Title","offer_id":47870946279679,"sku":"JFMSV00606","price":257.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/1_b37f5053-7124-43d2-949b-740de7308b8d.jpg?v=1765849031"},{"product_id":"upvc-3-way-motorized-ball-valve-t2-type-union-socket-end-2-wire-auto-return-dc-24v-with-manual-override","title":"1\/2\" UPVC 3-Way Motorized Ball Valve (T2 Type), Union \u0026 Socket End, 2 Wire Auto Return, DC 24V, with Manual Override","description":"\u003ch2 data-slate-node=\"element\"\u003e\u003cstrong\u003eIntroduction\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan class=\"\" data-para-id=\"0\" data-sent-id=\"VMd4PNE2Je\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-string=\"true\"\u003e\u003cspan data-slate-fragment=\"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\"\u003e\u003cspan\u003eThis \u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eUPVC 3-way\u003c\/strong\u003e\u003c\/span\u003e motorized ball valve provides an alternative solution to our standard brass\/stainless steel threaded ball valves currently available. Distinguished from NPT\/G threaded connections, it adopts \u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eAmerican standard socket end \u0026amp; union connection\u003c\/strong\u003e\u003c\/span\u003e, which balances stable sealing performance with the convenience of quick disassembly and maintenance. Equipped with a \u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003e2-wire auto-return\u003c\/strong\u003e\u003c\/span\u003e, the valve switches flow path via power on\/off, with EPDM seals ensuring reliable operation. It is the ideal choice for water treatment, HVAC, and low-pressure industrial fluid handling applications. For other connection standards, please contact our customer service.\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan class=\"\" data-para-id=\"0\" data-sent-id=\"VMd4PNE2Je\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-string=\"true\"\u003e\u003cspan data-slate-fragment=\"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\"\u003e\u003cspan\u003eThis 3-way valve series offers L-type and T-type configurations (2 options for T-type: T1\/T2). Please note the distinction when purchasing (refer to the main images for flow path type details).\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan class=\"\" data-para-id=\"0\" data-sent-id=\"VMd4PNE2Je\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-string=\"true\"\u003e\u003cspan data-slate-fragment=\"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\"\u003e\u003cspan\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eNOTE:\u003c\/strong\u003e\u003c\/span\u003e This auto-return ball valve requires a min. power-on duration of 60 seconds (≥60s) . This step is mandatory on first commissioning or after prolonged power cut to ensure reliable auto-reset performance.\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\n\u003cspan style=\"display:inline-block;\"\u003eTo learn how to use this product, please refer to the \u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/Manual-%20USS-UPVC-3way.pdf\" target=\"_blank\"\u003euser manual\u003c\/a\u003e.\u003c\/span\u003e\u003ch2 data-slate-node=\"element\"\u003e\u003cstrong\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan class=\"\" data-para-id=\"0\" data-sent-id=\"BP90d2vEme\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-string=\"true\"\u003eSpecifications\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan class=\"\" data-para-id=\"1\" data-sent-id=\"Bw2DL98jjz\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-string=\"true\"\u003e\u003cspan\u003eValve Port Type: 3 Way (T2 Type)\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan class=\"\" data-para-id=\"1\" data-sent-id=\"Bw2DL98jjz\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-string=\"true\"\u003eModel: USS-MSV611\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan class=\"\" data-para-id=\"2\" data-sent-id=\"z9ajXPEDJz\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-string=\"true\"\u003eSize: 1\/2\"\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003eConnection: Union \u0026amp; Socket End\u003cbr\u003eSocket Inside Diameter: 21.3mm\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-para-id=\"5\" data-sent-id=\"zrZan5bjLz\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-string=\"true\"\u003eMaterial: UPVC\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan class=\"\" data-para-id=\"7\" data-sent-id=\"zlxm27rW1z\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-string=\"true\"\u003eWorking Voltage: DC 24V\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan class=\"\" data-para-id=\"8\" data-sent-id=\"BD2jakZR0V\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-string=\"true\"\u003eMax Power: 36W\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan class=\"\" data-para-id=\"9\" data-sent-id=\"eLL276pXye\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-string=\"true\"\u003eMax Torque: 20 N·m\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan class=\"\" data-para-id=\"10\" data-sent-id=\"Vdompj0KRe\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-string=\"true\"\u003eMax. Pressure: 232 psi\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\n\u003cspan data-slate-node=\"text\"\u003e\u003cspan class=\"\" data-para-id=\"11\" data-sent-id=\"ebomx1EKpV\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-string=\"true\"\u003eMedium Temp: 33.8\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-para-id=\"11\" data-sent-id=\"BP90d2vEZe\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-string=\"true\"\u003e℉ \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-para-id=\"11\" data-sent-id=\"VQaxZEjJ9V\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-string=\"true\"\u003eto 104\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-para-id=\"11\" data-sent-id=\"Vpgw96Ljre\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-string=\"true\"\u003e℉\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan class=\"\" data-para-id=\"12\" data-sent-id=\"VW6NOZM1Ge\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-string=\"true\"\u003eIP Rating: IP65\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan class=\"\" data-para-id=\"13\" data-sent-id=\"B89jkb2lpe\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-string=\"true\"\u003eLife Expectancy: 20,000Cycles\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-para-id=\"14\" data-sent-id=\"V1dK9g4RWe\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-string=\"true\"\u003eClose\/Open Time: 10-12s\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan class=\"\" data-para-id=\"15\" data-sent-id=\"Bv2ldwWjPB\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-string=\"true\"\u003eWiring: 2 wire,auto return\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan class=\"\" data-para-id=\"16\" data-sent-id=\"ejq2ZMajdB\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-string=\"true\"\u003eManual Function: Yes\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan class=\"\" data-para-id=\"17\" data-sent-id=\"VNEOo5821e\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-string=\"true\"\u003eSignal feedback function: No\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-fragment=\"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\" data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-para-id=\"18\" data-sent-id=\"zn9m4AljMV\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-string=\"true\"\u003eSeal: EPDM\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-fragment=\"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\" data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-para-id=\"18\" data-sent-id=\"zn9m4AljMV\" data-slate-leaf=\"true\"\u003e\u003cspan data-slate-string=\"true\"\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003eNOTE:\u003c\/span\u003e\u003c\/strong\u003e Three-way valves are not categorized as normally open (NO) or normally closed (NC). For 2-wire auto-reset models, resetting means returning to the default passage state under power-off conditions.\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- TERMINOLOGY_UPDATED: flow direction → flow path - 2026-03-11 10:26:06 --\u003e","brand":"U.S. Solid","offers":[{"title":"Default Title","offer_id":47870946771199,"sku":"JFMSV00611","price":257.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/1_9cb976c0-79e1-42b2-923a-d87c53f8f0fa.jpg?v=1765849424"},{"product_id":"1-2-upvc-motorized-ball-valve-2-wire-auto-return-with-manual-function-9-36v-ac-dc-normally-closed","title":"1\/2\" UPVC Motorized Ball Valve - 2 Wire Auto Return with Manual Function, 9-36V AC\/DC, Normally Closed","description":"\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e \u003cmeta content=\"width=device-width, initial-scale=1.0\" name=\"viewport\"\u003e\u003c\/p\u003e\n\u003cstyle\u003e\n        \n        .desktop-img {\n            display: block;\n        }\n        .mobile-img {\n            display: none;\n        } \n        \n        .section-title {\n            font-size: 22px;\n            line-height: 22px;\n            font-weight: bold;\n            margin: 15px 0 5px; \n            font-family: Arial;\n        }\n        \n        .section-title2 {\n            font-size: 22px;\n            line-height: 22px;\n            font-weight: bold;\n            margin: 15px 0 3px; \n            font-family: Arial;\n        }\n       \n        .section-title3 {\n            font-size: 22px;\n            line-height: 22px;\n            font-weight: bold;\n            margin: 15px 0 10px; \n            font-family: Arial;\n        }\n\n        \n        .section-description {\n            font-size: 16px;\n            line-height: 26px;\n            margin-top: 0px;\n            margin-bottom: 5px; \n            font-family: Arial;\n        }\n      \n        .faq {\n            font-size: 16px; \n            margin: 0; \n            line-height: 26px; \n            background-color: #f2f2f2; \n            padding: 5px;\n        }\n        \n        .section-description2 {\n            font-size: 16px;\n            line-height: 26px;\n            margin: 0px; \n            font-family: Arial;\n        }\n        \n.parameters-table-wrapper {\n    overflow-x: auto; \n    -webkit-overflow-scrolling: touch; \n    margin-top: 0px;\n}\n\n\n.parameters-table {\n    width: 100%;\n    min-width: 1000px;\n    border-collapse: collapse;\n    margin-top: 0px;\n}\n\n.parameters-table th, .parameters-table td {\n    border-top: 1.2px solid #a6a6a6; \n    border-bottom: 1.2px solid #a6a6a6;  \n    border-left: none;  \n    border-right: none;  \n    padding: 5px 2px;\n    text-align: left;\n    font-size: 16px;\n    line-height: 16px;\n}\n\n.parameters-table th {\n    background-color: #f2f2f2;\n    color: #2c2c2c;\n    font-weight: bold;\n}\n\n\n.parameters-table .bg-gray {\n    background-color: #f2f2f2;  \n}\n\n\n.options-table-wrapper {\n    overflow-x: auto; \n    -webkit-overflow-scrolling: touch; \n    margin-top: 0px;\n}\n\n.options-table {\n    width: 100%;\n    min-width: 1000px; \n    border-collapse: collapse;\n    margin-top: 0px;\n    box-shadow: 0 6px 25px rgba(0, 0, 0, 0.1); \n}\n\n.options-table th, .options-table td {\n    border: 2px solid #000;  \n    padding: 5px 2px;  \n    text-align: center;\n    font-size: 16px;\n    line-height: 16px;\n}\n\n.options-table th {\n    background-color: #f2f2f2;\n    color: #2c2c2c;\n    font-weight: bold;\n}\n\n\n.parameters-table2 {\n    width: 100%;\n    min-width: 1000px; \n    border-collapse: collapse;\n    margin-top: 0px;\n}\n\n.parameters-table2 th, .parameters-table2 td {\n    border-top: 1.2px solid #a6a6a6;  \n    border-bottom: 1.2px solid #a6a6a6; \n    border-left: none;  \n    border-right: none; \n    padding: 5px 2px;\n    text-align: center;\n    font-size: 16px;\n    line-height: 16px;\n}\n\n.parameters-table2 th {\n    background-color: #f2f2f2;\n    color: #2c2c2c;\n    font-weight: bold;\n}\n\n\n.parameters-table2 .bg-gray {\n    background-color: #f2f2f2;  \n}\n\n\n.options-table-wrapper2 {\n    overflow-x: auto; \n    -webkit-overflow-scrolling: touch; \n    margin-top: 0px;\n}\n\n        .instruction-container {\n             display: flex;\n             justify-content: space-between;\n             align-items: flex-start;\n             gap: 10px; \/* Adds space between the video and the text *\/\n             margin-bottom: 0px; \/* Adds some space below the section *\/\n        }\n\n      \n        .img-container {\n              width: 50%; \n             display: flex;\n             justify-content: center; \n        }\n\n      \n        .text-container {\n               width: 50%; \n             font-size: 16px;\n             font-family: Arial;\n             \n         }\n\n         .instruction-container2 {\n             display: flex;\n             justify-content: space-between;\n             align-items: flex-start;\n             gap: 10px; \/* Adds space between the video and the text *\/\n             margin-bottom: 0px; \/* Adds some space below the section *\/\n        }\n\n      \n        .img-container2 {\n             width: 50%; \n             display: flex;\n             justify-content: center; \n        }\n\n      \n        .text-container2 {\n             width: 50%; \n            display: flex;\n             justify-content: center;\n         }\n\n\n@media (max-width: 768px) {\n    .parameters-table th, .parameters-table td {\n        font-size: 14px; \n        padding: 8px 4px; \n    }\n\n   \n    .options-table th, .options-table td {\n        font-size: 14px; \n        padding: 8px 4px;\n    }\n\n    .parameters-table-wrapper {\n        overflow-x: auto;\n    }\n    .parameters-table2 th, .parameters-table2 td {\n        font-size: 14px; \n        padding: 8px 4px; \n    }\n    .parameters-table-wrapper2 {\n        overflow-x: auto;\n    }\n    .desktop-img {\n                display: none;\n            }\n            .mobile-img {\n                display: block; \n            }\n    .instruction-container {\n                flex-direction: column; \n                align-items: center;\n            }\n\n            .img-container, .text-container {\n                width: 100%; \/* Both take full width *\/\n                margin-bottom: 0px; \n            }\n            .instruction-container2 {\n                flex-direction: column; \n                align-items: center;\n            }\n\n            .img-container2, .text-container2 {\n                width: 100%; \/* Both take full width *\/\n                margin-bottom: 0px; \n            }\n    \n}\n\n@media (max-width: 480px) {\n    .parameters-table th, .parameters-table td {\n        font-size: 12px; \n        padding: 6px 3px; \n    }\n\n    \n    .options-table th, .options-table td {\n        font-size: 12px; \n    }\n\n    .parameters-table-wrapper {\n        overflow-x: auto;\n    }\n    .parameters-table2 th, .parameters-table2 td {\n        font-size: 12px; \n        padding: 6px 3px; \n    }\n    .parameters-table-wrapper2 {\n        overflow-x: auto;\n    }\n    .desktop-img {\n                display: none; \n            }\n            .mobile-img {\n                display: block; \n            }\n    .instruction-container {\n                flex-direction: column; \n            }\n            .instruction-container2 {\n                flex-direction: column; \n            }\n    \n}\n    \u003c\/style\u003e\n\u003c!-- background --\u003e\n\u003cp\u003e\u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/MSV121.jpg\"\u003e \u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/121.jpg\"\u003e\u003c\/p\u003e\n\u003c!-- Introduction --\u003e\n\u003cdiv\u003e\n\u003ch2 class=\"section-title\"\u003eIntroduction\u003c\/h2\u003e\n\u003cp class=\"section-description\"\u003eThis series of UPVC electric ball valves is an upgraded version with manual function based on the conventional UPVC electric ball valves. It combines the convenience of electric control with the safety of manual control, and is suitable for various working conditions. \u003cbr\u003eThe valve adopts a two-wire automatic reset design. The manual function allows users to manually open or close the valve in case of sudden power failure or no power supply, which effectively avoids working condition stagnation caused by power failure and ensures the continuity and flexibility of use. The whole valve is made of UPVC material, which is lighter, more economical and practical compared with brass or stainless steel materials.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- Applications--\u003e\n\u003ch2 class=\"section-title2\"\u003eApplications\u003c\/h2\u003e\n\u003cp\u003e\u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/JFMSV461-a.jpg\"\u003e \u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/JFMSV461-a-p.jpg\"\u003e\u003c\/p\u003e\n\u003c!-- Features --\u003e\n\u003cdiv\u003e\n\u003ch2 class=\"section-title\"\u003eFeatures\u003c\/h2\u003e\n\u003cul class=\"section-description2\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eNormally Closed:\u003c\/strong\u003eClosed when unpowered, opens when energized.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNPT \/ G Threading:\u003c\/strong\u003e NPT (National Pipe Taper) and G (BSPP) to accommodate diverse global specifications, ensuring a secure seal with \u003ca href=\"https:\/\/ussolid.com\/products\/u-s-solid-10-rolls-0-7-inch-w-x-905-inches-l-teflon-tape-plumbers-tape-yellow-shell-html?_pos=3\u0026amp;_sid=7aa2e2725\u0026amp;_ss=r\" target=\"_blank\"\u003eteflon tape\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eValve Body Material:\u003c\/strong\u003e Constructed from UPVC, offering strong corrosion resistance, lower cost, lightweight and easy installation, with lower temperature and pressure resistance than brass and stainless steel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e9V-36V AC\/DC:\u003c\/strong\u003e Works effectively over entire voltage range, this motorized ball valve will open or close valve in 6~8 seconds.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e2 Wire Auto Return:\u003c\/strong\u003e Simple two-wire connection, automatically returning to its safe state when power is removed.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManual Function:\u003c\/strong\u003e Enables emergency actuation via a dedicated hand knob, ensuring the valve can be quickly opened or closed without electrical power.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/JFMSV121-1.jpg\"\u003e \u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/JFMSV121-1-p-1.jpg\"\u003e \u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/JFMSV121-1-p-2.png\"\u003e\u003c\/p\u003e\n\u003c!-- User Manual --\u003e\n\u003ch2 class=\"section-title\"\u003eUser Manual\u003c\/h2\u003e\n\u003cp class=\"section-description\"\u003eTo learn how to use this product, please refer to the \u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/Manual-U.S.%20Solid%20USS-MSV%20Motorized%20Ball%20Valves%20with%20Manual%20Function.pdf\" target=\"_blank\"\u003euser manual. \u003c\/a\u003e\u003c\/p\u003e\n\u003c!-- Technical Data --\u003e\n\u003ch2 class=\"section-title3\"\u003eTechnical Data\u003c\/h2\u003e\n\u003cdiv class=\"parameters-table-wrapper\"\u003e\n\u003ctable class=\"parameters-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eUSS-MSV00121\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003ePort Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1\/2\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eThread Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eNPT\/G\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eBody Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eUPVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eMax Torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2 Nm\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eWiring Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2 Wire Auto Return\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eOperation Mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eNormally Closed\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eFlow Aperture\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e15 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eBore Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eFull Port\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eGasket\/Diaphragm\/Seal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003ePTFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eOperating Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e6-8s\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eAC\/DC 9-36V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eIP Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIP65\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eMax Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e5W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eMedium Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e32℉-131℉(0℃-55℃)\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eLife Expectancy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e50,000 to 80,000 Cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eMax Medium Pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e145 PSI (1.0 Mpa)\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eSuitable Media\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eWater, air, oil and gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eGross Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.6 lbs\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003ePacking Dimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e3.2\"x3.7\"x5.2\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp class=\"section-description\"\u003e*To view the full table on mobile, please swipe left or right on the screen.\u003c\/p\u003e\n\n\u003ch2 class=\"section-title3\"\u003eCe Certified Quality \u0026amp; Safety\u003c\/h2\u003e\n\u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/CE\/CE-EMC.jpg\"\u003e\n\u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/CE\/CE-EMC.jpg\"\u003e\n\u003ch2 class=\"section-title\"\u003eWIRING\u003c\/h2\u003e\n\u003cdiv class=\"instruction-container2\"\u003e\n\u003cdiv class=\"img-container2\"\u003e\u003cimg alt=\"\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" style=\"width: 100%; height: auto;\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"text-container\"\u003e\u003cimg alt=\"\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" style=\"width: 100%; height: auto;\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp class=\"section-description\"\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e The product shown in the demonstration GIF may not match the actual product in this listing (e.g., differences in normally open (NO) or normally closed (NC) types). This is normal, and the GIF is intended to demonstrate the wiring method for a 2-wire auto return motorized ball valve.\u003c\/p\u003e\n\u003c!-- Manual Function --\u003e\n\u003ch2 class=\"section-title\"\u003eManual Function\u003c\/h2\u003e\n\u003cp class=\"section-description\"\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e For the 2-wire auto-reset model, wait briefly before manual operation to allow the capacitor to discharge fully before turning the handwheel.\u003c\/p\u003e\n\u003cdiv class=\"instruction-container\"\u003e\n\u003cdiv class=\"img-container\"\u003e\u003cimg alt=\"\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/jfmsv121-manual-function.jpg\" style=\"width: 100%; height: auto;\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"text-container\"\u003e\n\u003cp class=\"section-title\"\u003eRed arrow\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003eThe valves is fully closed when the red arrow on the position indicator ② points to \"0\"(vertical to the pipe).Likewise,the valve is fully open when it points to \"90\"(parallel to the pipe).\u003c\/p\u003e\n\u003cp class=\"section-title\"\u003eSteps\u003c\/p\u003e\n\u003cul class=\"section-description2\"\u003e\n\u003cli\u003eBefore manual operation, ensure the valve is in a power-off state.\u003c\/li\u003e\n\u003cli\u003eFirst, gently pull up the handwheel. At this point, rotating it will open or close the passage. You will feel a slight lift of the rod when pulling up; if it cannot be lifted, try rotating it to adjust the position.\u003c\/li\u003e\n\u003cli\u003eDo not use excessive force. While rotating, pay attention to the red line in the indicator window to avoid over-operation.\u003c\/li\u003e\n\u003cli\u003eAfter completing the manual operation, press down the handwheel to ensure the normal operation of the electric function.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- FAQ --\u003e\n\u003ch2 class=\"section-title\"\u003eFAQ\u003c\/h2\u003e\n\u003cp class=\"faq\"\u003e\u003cb\u003eProblem 1: What is the difference between N.C. (Normally Closed) and N.O. (Normally Open)?\u003c\/b\u003e\u003c\/p\u003e\n\u003cul class=\"section-description2\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eNormally Closed (NC):\u003c\/strong\u003e Valve remains closed when power is off, opening only when energized. Ideal for fail-safe closed applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNormally Open (NO):\u003c\/strong\u003e Valve remains open when power is off, closing only when energized. Ideal for fail-safe open applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"faq\"\u003e\u003cb\u003eProblem 2: What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n\u003cul class=\"section-description2\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eFull Port:\u003c\/strong\u003e Matches pipe diameter, minimal flow restriction, ideal for high flow and low pressure drop.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard Port:\u003c\/strong\u003e Smaller than pipe diameter, higher resistance, suitable for general flow and pressure needs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"faq\"\u003e\u003cb\u003eProblem 3: Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\u003cstrong\u003eNO.\u003c\/strong\u003e This valve is industrial-grade and not recommended for potable water applications.\u003c\/p\u003e\n\u003cp class=\"faq\"\u003e\u003cb\u003eProblem 4: For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n\u003cp class=\"faq\"\u003e\u003cb\u003eProblem 5: Why can't the handwheel be turned when using the manual function?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003eFor valves with automatic reset, if the handwheel cannot be turned despite following the correct procedure, it is usually because the capacitor in the valve has not fully discharged. Wait for several dozen seconds until the capacitor is discharged, then the manual function can be used normally.\u003c\/p\u003e\n\u003c!-- background --\u003e\n\u003cp\u003e\u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHSV\/jfhsv\/jfhsv-ptfe-viton.png\"\u003e \u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHSV\/jfhsv\/jfhsv-ptfe-viton-p.png\"\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e*\u003cstrong\u003eImportant:\u003c\/strong\u003e Check marks (√) denote conditional suitability only; crosses (×) indicate complete incompatibility.\u003c\/p\u003e","brand":"U.S. Solid","offers":[{"title":"NPT","offer_id":47872136741119,"sku":"JFMSV00121","price":42.49,"currency_code":"USD","in_stock":true},{"title":"G","offer_id":47872136773887,"sku":"JFMSV00121-G","price":37.39,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/4_c0ba9c37-f897-44e6-adf0-2f09a85fed26.png?v=1770198046"},{"product_id":"3-4-upvc-motorized-ball-valve-2-wire-auto-return-with-manual-function-9-36v-ac-dc-normally-closed","title":"3\/4\" UPVC Motorized Ball Valve - 2 Wire Auto Return with Manual Function, 9-36V AC\/DC, Normally Closed","description":"\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e \u003cmeta content=\"width=device-width, initial-scale=1.0\" name=\"viewport\"\u003e\u003c\/p\u003e\n\u003cstyle\u003e\n        \n        .desktop-img {\n            display: block;\n        }\n        .mobile-img {\n            display: none;\n        } \n        \n        .section-title {\n            font-size: 22px;\n            line-height: 22px;\n            font-weight: bold;\n            margin: 15px 0 5px; \n            font-family: Arial;\n        }\n        \n        .section-title2 {\n            font-size: 22px;\n            line-height: 22px;\n            font-weight: bold;\n            margin: 15px 0 3px; \n            font-family: Arial;\n        }\n       \n        .section-title3 {\n            font-size: 22px;\n            line-height: 22px;\n            font-weight: bold;\n            margin: 15px 0 10px; \n            font-family: Arial;\n        }\n\n        \n        .section-description {\n            font-size: 16px;\n            line-height: 26px;\n            margin-top: 0px;\n            margin-bottom: 5px; \n            font-family: Arial;\n        }\n      \n        .faq {\n            font-size: 16px; \n            margin: 0; \n            line-height: 26px; \n            background-color: #f2f2f2; \n            padding: 5px;\n        }\n        \n        .section-description2 {\n            font-size: 16px;\n            line-height: 26px;\n            margin: 0px; \n            font-family: Arial;\n        }\n        \n.parameters-table-wrapper {\n    overflow-x: auto; \n    -webkit-overflow-scrolling: touch; \n    margin-top: 0px;\n}\n\n\n.parameters-table {\n    width: 100%;\n    min-width: 1000px;\n    border-collapse: collapse;\n    margin-top: 0px;\n}\n\n.parameters-table th, .parameters-table td {\n    border-top: 1.2px solid #a6a6a6; \n    border-bottom: 1.2px solid #a6a6a6;  \n    border-left: none;  \n    border-right: none;  \n    padding: 5px 2px;\n    text-align: left;\n    font-size: 16px;\n    line-height: 16px;\n}\n\n.parameters-table th {\n    background-color: #f2f2f2;\n    color: #2c2c2c;\n    font-weight: bold;\n}\n\n\n.parameters-table .bg-gray {\n    background-color: #f2f2f2;  \n}\n\n\n.options-table-wrapper {\n    overflow-x: auto; \n    -webkit-overflow-scrolling: touch; \n    margin-top: 0px;\n}\n\n.options-table {\n    width: 100%;\n    min-width: 1000px; \n    border-collapse: collapse;\n    margin-top: 0px;\n    box-shadow: 0 6px 25px rgba(0, 0, 0, 0.1); \n}\n\n.options-table th, .options-table td {\n    border: 2px solid #000;  \n    padding: 5px 2px;  \n    text-align: center;\n    font-size: 16px;\n    line-height: 16px;\n}\n\n.options-table th {\n    background-color: #f2f2f2;\n    color: #2c2c2c;\n    font-weight: bold;\n}\n\n\n.parameters-table2 {\n    width: 100%;\n    min-width: 1000px; \n    border-collapse: collapse;\n    margin-top: 0px;\n}\n\n.parameters-table2 th, .parameters-table2 td {\n    border-top: 1.2px solid #a6a6a6;  \n    border-bottom: 1.2px solid #a6a6a6; \n    border-left: none;  \n    border-right: none; \n    padding: 5px 2px;\n    text-align: center;\n    font-size: 16px;\n    line-height: 16px;\n}\n\n.parameters-table2 th {\n    background-color: #f2f2f2;\n    color: #2c2c2c;\n    font-weight: bold;\n}\n\n\n.parameters-table2 .bg-gray {\n    background-color: #f2f2f2;  \n}\n\n\n.options-table-wrapper2 {\n    overflow-x: auto; \n    -webkit-overflow-scrolling: touch; \n    margin-top: 0px;\n}\n\n        .instruction-container {\n             display: flex;\n             justify-content: space-between;\n             align-items: flex-start;\n             gap: 10px; \/* Adds space between the video and the text *\/\n             margin-bottom: 0px; \/* Adds some space below the section *\/\n        }\n\n      \n        .img-container {\n              width: 50%; \n             display: flex;\n             justify-content: center; \n        }\n\n      \n        .text-container {\n               width: 50%; \n             font-size: 16px;\n             font-family: Arial;\n             \n         }\n\n         .instruction-container2 {\n             display: flex;\n             justify-content: space-between;\n             align-items: flex-start;\n             gap: 10px; \/* Adds space between the video and the text *\/\n             margin-bottom: 0px; \/* Adds some space below the section *\/\n        }\n\n      \n        .img-container2 {\n             width: 50%; \n             display: flex;\n             justify-content: center; \n        }\n\n      \n        .text-container2 {\n             width: 50%; \n            display: flex;\n             justify-content: center;\n         }\n\n\n@media (max-width: 768px) {\n    .parameters-table th, .parameters-table td {\n        font-size: 14px; \n        padding: 8px 4px; \n    }\n\n   \n    .options-table th, .options-table td {\n        font-size: 14px; \n        padding: 8px 4px;\n    }\n\n    .parameters-table-wrapper {\n        overflow-x: auto;\n    }\n    .parameters-table2 th, .parameters-table2 td {\n        font-size: 14px; \n        padding: 8px 4px; \n    }\n    .parameters-table-wrapper2 {\n        overflow-x: auto;\n    }\n    .desktop-img {\n                display: none;\n            }\n            .mobile-img {\n                display: block; \n            }\n    .instruction-container {\n                flex-direction: column; \n                align-items: center;\n            }\n\n            .img-container, .text-container {\n                width: 100%; \/* Both take full width *\/\n                margin-bottom: 0px; \n            }\n            .instruction-container2 {\n                flex-direction: column; \n                align-items: center;\n            }\n\n            .img-container2, .text-container2 {\n                width: 100%; \/* Both take full width *\/\n                margin-bottom: 0px; \n            }\n    \n}\n\n@media (max-width: 480px) {\n    .parameters-table th, .parameters-table td {\n        font-size: 12px; \n        padding: 6px 3px; \n    }\n\n    \n    .options-table th, .options-table td {\n        font-size: 12px; \n    }\n\n    .parameters-table-wrapper {\n        overflow-x: auto;\n    }\n    .parameters-table2 th, .parameters-table2 td {\n        font-size: 12px; \n        padding: 6px 3px; \n    }\n    .parameters-table-wrapper2 {\n        overflow-x: auto;\n    }\n    .desktop-img {\n                display: none; \n            }\n            .mobile-img {\n                display: block; \n            }\n    .instruction-container {\n                flex-direction: column; \n            }\n            .instruction-container2 {\n                flex-direction: column; \n            }\n    \n}\n    \u003c\/style\u003e\n\u003c!-- background --\u003e\n\u003cp\u003e\u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/MSV121.jpg\"\u003e \u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/121.jpg\"\u003e\u003c\/p\u003e\n\u003c!-- Introduction --\u003e\n\u003cdiv\u003e\n\u003ch2 class=\"section-title\"\u003eIntroduction\u003c\/h2\u003e\n\u003cp class=\"section-description\"\u003eThis series of UPVC electric ball valves is an upgraded version with manual function based on the conventional UPVC electric ball valves. It combines the convenience of electric control with the safety of manual control, and is suitable for various working conditions. \u003cbr\u003eThe valve adopts a two-wire automatic reset design. The manual function allows users to manually open or close the valve in case of sudden power failure or no power supply, which effectively avoids working condition stagnation caused by power failure and ensures the continuity and flexibility of use. The whole valve is made of UPVC material, which is lighter, more economical and practical compared with brass or stainless steel materials.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- Applications--\u003e\n\u003ch2 class=\"section-title2\"\u003eApplications\u003c\/h2\u003e\n\u003cp\u003e\u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/JFMSV461-a.jpg\"\u003e \u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/JFMSV461-a-p.jpg\"\u003e\u003c\/p\u003e\n\u003c!-- Features --\u003e\n\u003cdiv\u003e\n\u003ch2 class=\"section-title\"\u003eFeatures\u003c\/h2\u003e\n\u003cul class=\"section-description2\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eNormally Closed:\u003c\/strong\u003eClosed when unpowered, opens when energized.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNPT \/ G Threading:\u003c\/strong\u003e NPT (National Pipe Taper) and G (BSPP) to accommodate diverse global specifications, ensuring a secure seal with \u003ca href=\"https:\/\/ussolid.com\/products\/u-s-solid-10-rolls-0-7-inch-w-x-905-inches-l-teflon-tape-plumbers-tape-yellow-shell-html?_pos=3\u0026amp;_sid=7aa2e2725\u0026amp;_ss=r\" target=\"_blank\"\u003eteflon tape\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eValve Body Material:\u003c\/strong\u003e Constructed from UPVC, offering strong corrosion resistance, lower cost, lightweight and easy installation, with lower temperature and pressure resistance than brass and stainless steel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e9V-36V AC\/DC:\u003c\/strong\u003e Works effectively over entire voltage range, this motorized ball valve will open or close valve in 6~8 seconds.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e2 Wire Auto Return:\u003c\/strong\u003e Simple two-wire connection, automatically returning to its safe state when power is removed.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManual Function:\u003c\/strong\u003e Enables emergency actuation via a dedicated hand knob, ensuring the valve can be quickly opened or closed without electrical power.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/JFMSV121-1.jpg\"\u003e \u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/JFMSV121-1-p-1.jpg\"\u003e \u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/JFMSV121-1-p-2.png\"\u003e\u003c\/p\u003e\n\u003c!-- User Manual --\u003e\n\u003ch2 class=\"section-title\"\u003eUser Manual\u003c\/h2\u003e\n\u003cp class=\"section-description\"\u003eTo learn how to use this product, please refer to the \u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/Manual-U.S.%20Solid%20USS-MSV%20Motorized%20Ball%20Valves%20with%20Manual%20Function.pdf\" target=\"_blank\"\u003euser manual. \u003c\/a\u003e\u003c\/p\u003e\n\u003c!-- Technical Data --\u003e\n\u003ch2 class=\"section-title3\"\u003eTechnical Data\u003c\/h2\u003e\n\u003cdiv class=\"parameters-table-wrapper\"\u003e\n\u003ctable class=\"parameters-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eUSS-MSV00122\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003ePort Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e3\/4\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eThread Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eNPT\/G\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eBody Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eUPVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eMax Torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2 Nm\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eWiring Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2 Wire Auto Return\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eOperation Mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eNormally Closed\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eFlow Aperture\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e20 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eBore Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eFull Port\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eGasket\/Diaphragm\/Seal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003ePTFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eOperating Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e6-8s\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eAC\/DC 9-36V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eIP Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIP65\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eMax Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e5W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eMedium Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e32℉-131℉(0℃-55℃)\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eLife Expectancy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e50,000 to 80,000 Cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eMax Medium Pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e145 PSI (1.0 Mpa)\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eSuitable Media\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eWater, air, oil and gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eGross Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.68 lbs\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003ePacking Dimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2.72\"x3.03\"x3.98\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp class=\"section-description\"\u003e*To view the full table on mobile, please swipe left or right on the screen.\u003c\/p\u003e\n\n\u003ch2 class=\"section-title3\"\u003eCe Certified Quality \u0026amp; Safety\u003c\/h2\u003e\n\u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/CE\/CE-EMC.jpg\"\u003e\n\u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/CE\/CE-EMC.jpg\"\u003e\n\u003ch2 class=\"section-title\"\u003eWIRING\u003c\/h2\u003e\n\u003cdiv class=\"instruction-container2\"\u003e\n\u003cdiv class=\"img-container2\"\u003e\u003cimg alt=\"\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" style=\"width: 100%; height: auto;\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"text-container\"\u003e\u003cimg alt=\"\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" style=\"width: 100%; height: auto;\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp class=\"section-description\"\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e The product shown in the demonstration GIF may not match the actual product in this listing (e.g., differences in normally open (NO) or normally closed (NC) types). This is normal, and the GIF is intended to demonstrate the wiring method for a 2-wire auto return motorized ball valve.\u003c\/p\u003e\n\u003c!-- Manual Function --\u003e\n\u003ch2 class=\"section-title\"\u003eManual Function\u003c\/h2\u003e\n\u003cp class=\"section-description\"\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e For the 2-wire auto-reset model, wait briefly before manual operation to allow the capacitor to discharge fully before turning the handwheel.\u003c\/p\u003e\n\u003cdiv class=\"instruction-container\"\u003e\n\u003cdiv class=\"img-container\"\u003e\u003cimg alt=\"\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/jfmsv121-manual-function.jpg\" style=\"width: 100%; height: auto;\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"text-container\"\u003e\n\u003cp class=\"section-title\"\u003eRed arrow\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003eThe valves is fully closed when the red arrow on the position indicator ② points to \"0\"(vertical to the pipe).Likewise,the valve is fully open when it points to \"90\"(parallel to the pipe).\u003c\/p\u003e\n\u003cp class=\"section-title\"\u003eSteps\u003c\/p\u003e\n\u003cul class=\"section-description2\"\u003e\n\u003cli\u003eBefore manual operation, ensure the valve is in a power-off state.\u003c\/li\u003e\n\u003cli\u003eFirst, gently pull up the handwheel. At this point, rotating it will open or close the passage. You will feel a slight lift of the rod when pulling up; if it cannot be lifted, try rotating it to adjust the position.\u003c\/li\u003e\n\u003cli\u003eDo not use excessive force. While rotating, pay attention to the red line in the indicator window to avoid over-operation.\u003c\/li\u003e\n\u003cli\u003eAfter completing the manual operation, press down the handwheel to ensure the normal operation of the electric function.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- FAQ --\u003e\n\u003ch2 class=\"section-title\"\u003eFAQ\u003c\/h2\u003e\n\u003cp class=\"faq\"\u003e\u003cb\u003eProblem 1: What is the difference between N.C. (Normally Closed) and N.O. (Normally Open)?\u003c\/b\u003e\u003c\/p\u003e\n\u003cul class=\"section-description2\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eNormally Closed (NC):\u003c\/strong\u003e Valve remains closed when power is off, opening only when energized. Ideal for fail-safe closed applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNormally Open (NO):\u003c\/strong\u003e Valve remains open when power is off, closing only when energized. Ideal for fail-safe open applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"faq\"\u003e\u003cb\u003eProblem 2: What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n\u003cul class=\"section-description2\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eFull Port:\u003c\/strong\u003e Matches pipe diameter, minimal flow restriction, ideal for high flow and low pressure drop.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard Port:\u003c\/strong\u003e Smaller than pipe diameter, higher resistance, suitable for general flow and pressure needs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"faq\"\u003e\u003cb\u003eProblem 3: Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\u003cstrong\u003eNO.\u003c\/strong\u003e This valve is industrial-grade and not recommended for potable water applications.\u003c\/p\u003e\n\u003cp class=\"faq\"\u003e\u003cb\u003eProblem 4: For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n\u003cp class=\"faq\"\u003e\u003cb\u003eProblem 5: Why can't the handwheel be turned when using the manual function?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003eFor valves with automatic reset, if the handwheel cannot be turned despite following the correct procedure, it is usually because the capacitor in the valve has not fully discharged. Wait for several dozen seconds until the capacitor is discharged, then the manual function can be used normally.\u003c\/p\u003e\n\u003c!-- background --\u003e\n\u003cp\u003e\u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHSV\/jfhsv\/jfhsv-ptfe-viton.png\"\u003e \u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHSV\/jfhsv\/jfhsv-ptfe-viton-p.png\"\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e*\u003cstrong\u003eImportant:\u003c\/strong\u003e Check marks (√) denote conditional suitability only; crosses (×) indicate complete incompatibility.\u003c\/p\u003e","brand":"U.S. Solid","offers":[{"title":"NPT","offer_id":47872542048511,"sku":"JFMSV00122","price":44.49,"currency_code":"USD","in_stock":true},{"title":"G","offer_id":47872542081279,"sku":"JFMSV00122-G","price":39.39,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/4_5bd530d7-b49e-40a9-8ac7-efce0bc02b96.png?v=1770198626"},{"product_id":"1-upvc-motorized-ball-valve-2-wire-auto-return-with-manual-function-9-36v-ac-dc-normally-closed","title":"1\" UPVC Motorized Ball Valve - 2 Wire Auto Return with Manual Function, 9-36V AC\/DC, Normally Closed","description":"\u003cbody\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003cmeta content=\"width=device-width, initial-scale=1.0\" name=\"viewport\"\u003e\n\u003ctitle\u003eResponsive Page with Multiple Modules\u003c\/title\u003e\n\u003cstyle\u003e\n        \n        .desktop-img {\n            display: block;\n        }\n        .mobile-img {\n            display: none;\n        } \n        \n        .section-title {\n            font-size: 22px;\n            line-height: 22px;\n            font-weight: bold;\n            margin: 15px 0 5px; \n            font-family: Arial;\n        }\n        \n        .section-title2 {\n            font-size: 22px;\n            line-height: 22px;\n            font-weight: bold;\n            margin: 15px 0 3px; \n            font-family: Arial;\n        }\n       \n        .section-title3 {\n            font-size: 22px;\n            line-height: 22px;\n            font-weight: bold;\n            margin: 15px 0 10px; \n            font-family: Arial;\n        }\n\n        \n        .section-description {\n            font-size: 16px;\n            line-height: 26px;\n            margin-top: 0px;\n            margin-bottom: 5px; \n            font-family: Arial;\n        }\n      \n        .faq {\n            font-size: 16px; \n            margin: 0; \n            line-height: 26px; \n            background-color: #f2f2f2; \n            padding: 5px;\n        }\n        \n        .section-description2 {\n            font-size: 16px;\n            line-height: 26px;\n            margin: 0px; \n            font-family: Arial;\n        }\n        \n.parameters-table-wrapper {\n    overflow-x: auto; \n    -webkit-overflow-scrolling: touch; \n    margin-top: 0px;\n}\n\n\n.parameters-table {\n    width: 100%;\n    min-width: 1000px;\n    border-collapse: collapse;\n    margin-top: 0px;\n}\n\n.parameters-table th, .parameters-table td {\n    border-top: 1.2px solid #a6a6a6; \n    border-bottom: 1.2px solid #a6a6a6;  \n    border-left: none;  \n    border-right: none;  \n    padding: 5px 2px;\n    text-align: left;\n    font-size: 16px;\n    line-height: 16px;\n}\n\n.parameters-table th {\n    background-color: #f2f2f2;\n    color: #2c2c2c;\n    font-weight: bold;\n}\n\n\n.parameters-table .bg-gray {\n    background-color: #f2f2f2;  \n}\n\n\n.options-table-wrapper {\n    overflow-x: auto; \n    -webkit-overflow-scrolling: touch; \n    margin-top: 0px;\n}\n\n.options-table {\n    width: 100%;\n    min-width: 1000px; \n    border-collapse: collapse;\n    margin-top: 0px;\n    box-shadow: 0 6px 25px rgba(0, 0, 0, 0.1); \n}\n\n.options-table th, .options-table td {\n    border: 2px solid #000;  \n    padding: 5px 2px;  \n    text-align: center;\n    font-size: 16px;\n    line-height: 16px;\n}\n\n.options-table th {\n    background-color: #f2f2f2;\n    color: #2c2c2c;\n    font-weight: bold;\n}\n\n\n.parameters-table2 {\n    width: 100%;\n    min-width: 1000px; \n    border-collapse: collapse;\n    margin-top: 0px;\n}\n\n.parameters-table2 th, .parameters-table2 td {\n    border-top: 1.2px solid #a6a6a6;  \n    border-bottom: 1.2px solid #a6a6a6; \n    border-left: none;  \n    border-right: none; \n    padding: 5px 2px;\n    text-align: center;\n    font-size: 16px;\n    line-height: 16px;\n}\n\n.parameters-table2 th {\n    background-color: #f2f2f2;\n    color: #2c2c2c;\n    font-weight: bold;\n}\n\n\n.parameters-table2 .bg-gray {\n    background-color: #f2f2f2;  \n}\n\n\n.options-table-wrapper2 {\n    overflow-x: auto; \n    -webkit-overflow-scrolling: touch; \n    margin-top: 0px;\n}\n\n        .instruction-container {\n             display: flex;\n             justify-content: space-between;\n             align-items: flex-start;\n             gap: 10px; \/* Adds space between the video and the text *\/\n             margin-bottom: 0px; \/* Adds some space below the section *\/\n        }\n\n      \n        .img-container {\n              width: 50%; \n             display: flex;\n             justify-content: center; \n        }\n\n      \n        .text-container {\n               width: 50%; \n             font-size: 16px;\n             font-family: Arial;\n             \n         }\n\n         .instruction-container2 {\n             display: flex;\n             justify-content: space-between;\n             align-items: flex-start;\n             gap: 10px; \/* Adds space between the video and the text *\/\n             margin-bottom: 0px; \/* Adds some space below the section *\/\n        }\n\n      \n        .img-container2 {\n             width: 50%; \n             display: flex;\n             justify-content: center; \n        }\n\n      \n        .text-container2 {\n             width: 50%; \n            display: flex;\n             justify-content: center;\n         }\n\n\n@media (max-width: 768px) {\n    .parameters-table th, .parameters-table td {\n        font-size: 14px; \n        padding: 8px 4px; \n    }\n\n   \n    .options-table th, .options-table td {\n        font-size: 14px; \n        padding: 8px 4px;\n    }\n\n    .parameters-table-wrapper {\n        overflow-x: auto;\n    }\n    .parameters-table2 th, .parameters-table2 td {\n        font-size: 14px; \n        padding: 8px 4px; \n    }\n    .parameters-table-wrapper2 {\n        overflow-x: auto;\n    }\n    .desktop-img {\n                display: none;\n            }\n            .mobile-img {\n                display: block; \n            }\n    .instruction-container {\n                flex-direction: column; \n                align-items: center;\n            }\n\n            .img-container, .text-container {\n                width: 100%; \/* Both take full width *\/\n                margin-bottom: 0px; \n            }\n            .instruction-container2 {\n                flex-direction: column; \n                align-items: center;\n            }\n\n            .img-container2, .text-container2 {\n                width: 100%; \/* Both take full width *\/\n                margin-bottom: 0px; \n            }\n    \n}\n\n@media (max-width: 480px) {\n    .parameters-table th, .parameters-table td {\n        font-size: 12px; \n        padding: 6px 3px; \n    }\n\n    \n    .options-table th, .options-table td {\n        font-size: 12px; \n    }\n\n    .parameters-table-wrapper {\n        overflow-x: auto;\n    }\n    .parameters-table2 th, .parameters-table2 td {\n        font-size: 12px; \n        padding: 6px 3px; \n    }\n    .parameters-table-wrapper2 {\n        overflow-x: auto;\n    }\n    .desktop-img {\n                display: none; \n            }\n            .mobile-img {\n                display: block; \n            }\n    .instruction-container {\n                flex-direction: column; \n            }\n            .instruction-container2 {\n                flex-direction: column; \n            }\n    \n}\n    \u003c\/style\u003e\n\u003c!-- background --\u003e\n\u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/MSV121.jpg\"\u003e\n\u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/121.jpg\"\u003e\n\u003c!-- Introduction --\u003e\n\u003cdiv\u003e\n\u003ch2 class=\"section-title\"\u003eIntroduction\u003c\/h2\u003e\n\u003cp class=\"section-description\"\u003e\n            This series of UPVC electric ball valves is an upgraded version with manual function based on the conventional UPVC electric ball valves. It combines the convenience of electric control with the safety of manual control, and is suitable for various working conditions. \u003cbr\u003eThe valve adopts a two-wire automatic reset design. The manual function allows users to manually open or close the valve in case of sudden power failure or no power supply, which effectively avoids working condition stagnation caused by power failure and ensures the continuity and flexibility of use. The whole valve is made of UPVC material, which is lighter, more economical and practical compared with brass or stainless steel materials.\n        \u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- Applications--\u003e\n\u003ch2 class=\"section-title2\"\u003eApplications\u003c\/h2\u003e\n\u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/JFMSV461-a.jpg\"\u003e\n\u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/JFMSV461-a-p.jpg\"\u003e\n\u003c!-- Features --\u003e\n\u003cdiv\u003e\n\u003ch2 class=\"section-title\"\u003eFeatures\u003c\/h2\u003e\n\u003cul class=\"section-description2\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eNormally Closed:\u003c\/strong\u003eClosed when unpowered, opens when energized.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNPT \/ G Threading:\u003c\/strong\u003e NPT (National Pipe Taper) and G (BSPP) to accommodate diverse global specifications, ensuring a secure seal with \u003ca href=\"https:\/\/ussolid.com\/products\/u-s-solid-10-rolls-0-7-inch-w-x-905-inches-l-teflon-tape-plumbers-tape-yellow-shell-html?_pos=3\u0026amp;_sid=7aa2e2725\u0026amp;_ss=r\" target=\"_blank\"\u003eteflon tape\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eValve Body Material:\u003c\/strong\u003e Constructed from UPVC, offering strong corrosion resistance, lower cost, lightweight and easy installation, with lower temperature and pressure resistance than brass and stainless steel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e9V-36V AC\/DC:\u003c\/strong\u003e Works effectively over entire voltage range, this motorized ball valve will open or close valve in 6~8 seconds.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e2 Wire Auto Return:\u003c\/strong\u003e Simple two-wire connection, automatically returning to its safe state when power is removed.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManual Function:\u003c\/strong\u003e Enables emergency actuation via a dedicated hand knob, ensuring the valve can be quickly opened or closed without electrical power.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/JFMSV121-1.jpg\"\u003e\n\u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/JFMSV121-1-p-1.jpg\"\u003e\n\u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/JFMSV121-1-p-2.png\"\u003e\n\u003c!-- User Manual --\u003e\n\u003ch2 class=\"section-title\"\u003eUser Manual\u003c\/h2\u003e\n\u003cp class=\"section-description\"\u003e\n            To learn how to use this product, please refer to the \u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/Manual-U.S.%20Solid%20USS-MSV%20Motorized%20Ball%20Valves%20with%20Manual%20Function.pdf\" target=\"_blank\"\u003euser manual.\n    \u003c\/a\u003e\u003c\/p\u003e\n\u003c!-- Technical Data --\u003e\n\u003ch2 class=\"section-title3\"\u003eTechnical Data\u003c\/h2\u003e\n\u003cdiv class=\"parameters-table-wrapper\"\u003e\n\u003ctable class=\"parameters-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eUSS-MSV00123\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003ePort Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eThread Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eNPT\/G\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eBody Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eUPVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eMax Torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2 Nm\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eWiring Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2 Wire Auto Return\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eOperation Mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eNormally Closed\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eFlow Aperture\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e25 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eBore Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eFull Port\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eGasket\/Diaphragm\/Seal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003ePTFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eOperating Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e6-8s\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eAC\/DC 9-36V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eIP Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIP65\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eMax Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e5W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eMedium Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e32℉-131℉(0℃-55℃)\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eLife Expectancy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e50,000 to 80,000 Cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eMax Medium Pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e145 PSI (1.0 Mpa)\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eSuitable Media\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eWater, air, oil and gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eGross Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.75 lbs\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003ePacking Dimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2.87\"x3.23\"x4.49\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp class=\"section-description\"\u003e*To view the full table on mobile, please swipe left or right on the screen.\u003c\/p\u003e\n\n\u003ch2 class=\"section-title3\"\u003eCe Certified Quality \u0026amp; Safety\u003c\/h2\u003e\n\u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/CE\/CE-EMC.jpg\"\u003e\n\u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/CE\/CE-EMC.jpg\"\u003e\n\u003ch2 class=\"section-title\"\u003eWIRING\u003c\/h2\u003e\n\u003cdiv class=\"instruction-container2\"\u003e\n\u003cdiv class=\"img-container2\"\u003e\n\u003cimg alt=\"\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" style=\"width: 100%; height: auto;\"\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"text-container\"\u003e\n\u003cimg alt=\"\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" style=\"width: 100%; height: auto;\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp class=\"section-description\"\u003e\n\u003cstrong\u003eNote:\u003c\/strong\u003e The product shown in the demonstration GIF may not match the actual product in this listing (e.g., differences in normally open (NO) or normally closed (NC) types). This is normal, and the GIF is intended to demonstrate the wiring method for a 2-wire auto return motorized ball valve.\n        \u003c\/p\u003e\n\u003c!-- Manual Function --\u003e\n\u003ch2 class=\"section-title\"\u003eManual Function\u003c\/h2\u003e\n\u003cp class=\"section-description\"\u003e\n\u003cstrong\u003eNote:\u003c\/strong\u003e For the 2-wire auto-reset model, wait briefly before manual operation to allow the capacitor to discharge fully before turning the handwheel.\n        \u003c\/p\u003e\n\u003cdiv class=\"instruction-container\"\u003e\n\u003cdiv class=\"img-container\"\u003e\n\u003cimg alt=\"\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/jfmsv121-manual-function.jpg\" style=\"width: 100%; height: auto;\"\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"text-container\"\u003e\n\u003cp class=\"section-title\"\u003eRed arrow\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003eThe valves is fully closed when the red arrow on the position indicator ② points to \"0\"(vertical to the pipe).Likewise,the valve is fully open when it points to \"90\"(parallel to the pipe).\u003c\/p\u003e\n\u003cp class=\"section-title\"\u003eSteps\u003c\/p\u003e\n\u003cul class=\"section-description2\"\u003e\n\u003cli\u003eBefore manual operation, ensure the valve is in a power-off state.\u003c\/li\u003e\n\u003cli\u003eFirst, gently pull up the handwheel. At this point, rotating it will open or close the passage. You will feel a slight lift of the rod when pulling up; if it cannot be lifted, try rotating it to adjust the position.\u003c\/li\u003e\n\u003cli\u003eDo not use excessive force. While rotating, pay attention to the red line in the indicator window to avoid over-operation.\u003c\/li\u003e\n\u003cli\u003eAfter completing the manual operation, press down the handwheel to ensure the normal operation of the electric function.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- FAQ --\u003e\n\u003ch2 class=\"section-title\"\u003eFAQ\u003c\/h2\u003e\n\u003cp class=\"faq\"\u003e\u003cb\u003eProblem 1: What is the difference between N.C. (Normally Closed) and N.O. (Normally Open)?\u003c\/b\u003e\u003c\/p\u003e\n\u003cul class=\"section-description2\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eNormally Closed (NC):\u003c\/strong\u003e Valve remains closed when power is off, opening only when energized. Ideal for fail-safe closed applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNormally Open (NO):\u003c\/strong\u003e Valve remains open when power is off, closing only when energized. Ideal for fail-safe open applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"faq\"\u003e\u003cb\u003eProblem 2: What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n\u003cul class=\"section-description2\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eFull Port:\u003c\/strong\u003e Matches pipe diameter, minimal flow restriction, ideal for high flow and low pressure drop.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard Port:\u003c\/strong\u003e Smaller than pipe diameter, higher resistance, suitable for general flow and pressure needs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"faq\"\u003e\u003cb\u003eProblem 3: Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\u003cstrong\u003eNO.\u003c\/strong\u003e This valve is industrial-grade and not recommended for potable water applications.\u003c\/p\u003e\n\u003cp class=\"faq\"\u003e\u003cb\u003eProblem 4: For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n\u003cp class=\"faq\"\u003e\u003cb\u003eProblem 5: Why can't the handwheel be turned when using the manual function?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003eFor valves with automatic reset, if the handwheel cannot be turned despite following the correct procedure, it is usually because the capacitor in the valve has not fully discharged. Wait for several dozen seconds until the capacitor is discharged, then the manual function can be used normally.\u003c\/p\u003e\n\u003c!-- background --\u003e\n\u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHSV\/jfhsv\/jfhsv-ptfe-viton.png\"\u003e\n\u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHSV\/jfhsv\/jfhsv-ptfe-viton-p.png\"\u003e\n\u003cp class=\"section-description\"\u003e*\u003cstrong\u003eImportant:\u003c\/strong\u003e Check marks (√) denote conditional suitability only; crosses (×) indicate complete incompatibility.\u003c\/p\u003e\n\u003c\/body\u003e","brand":"U.S. Solid","offers":[{"title":"NPT","offer_id":47872627802367,"sku":"JFMSV00123","price":48.49,"currency_code":"USD","in_stock":true},{"title":"G","offer_id":47872627835135,"sku":"JFMSV00123-G","price":43.49,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/4_bebbcdec-78e7-4dd2-89c9-367920250438.png?v=1770198792"},{"product_id":"1-1-4-double-union-upvc-motorized-ball-valve-dc-24v-3-wire-single-control-normally-closed-with-manual-override-epdm-seal","title":"1-1\/4\" Double Union UPVC Motorized Ball Valve - DC 24V, 3-Wire Single-Control, with Manual Override \u0026 EPDM Seal","description":"\u003ch2 data-slate-node=\"element\"\u003e\u003cstrong\u003eIntroduction\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-slate-leaf=\"true\" data-sent-id=\"VMd4PNE2Je\" data-para-id=\"0\" class=\"\"\u003e\u003cspan data-slate-string=\"true\"\u003e\u003cspan data-slate-fragment=\"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\"\u003eOur electric UPVC ball valve series has been upgraded to include three larger sizes: 1-1\/4\", 1-1\/2\", and 2\". These larger valves feature a unique \u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eUS standard socket end\u003c\/strong\u003e\u003c\/span\u003e \u0026amp; \u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003edouble union connection\u003c\/span\u003e\u003c\/strong\u003e—enabling exceptional ease of installation and maintenance with a simple solvent cement bond, \u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eunlike\u003c\/strong\u003e\u003c\/span\u003e threaded NPT or G connections. For other connection standards, please contact our customer service.\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-slate-leaf=\"true\" data-sent-id=\"VMd4PNE2Je\" data-para-id=\"0\" class=\"\"\u003e\u003cspan data-slate-string=\"true\"\u003e\u003cspan data-slate-fragment=\"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\"\u003e\u003cspan data-slate-fragment=\"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\"\u003eThese valves utilize a \u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003e3-wire, single-control\u003c\/span\u003e\u003c\/strong\u003e configuration. \u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003eUnlike\u003c\/span\u003e\u003c\/strong\u003e the 2-wire auto-return model, this version does not automatically reset if power is lost; instead, it remains in its current position, providing stable operation for specific flow requirements. The 3-wire setup includes a common wire, a constant power wire, and a single control wire—simply toggle the control wire to open or close the valve. A manual override is also included for use during power outages. All valves have EPDM seals for reliable performance.\u003c\/span\u003e \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-slate-leaf=\"true\" data-sent-id=\"VMd4PNE2Je\" data-para-id=\"0\" class=\"\"\u003e\u003cspan data-slate-string=\"true\"\u003e\u003cspan data-slate-fragment=\"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\"\u003e\u003cspan data-slate-leaf=\"true\" data-sent-id=\"VAJ2GDn4Kz\" data-para-id=\"1\" class=\"\"\u003e\u003cspan data-slate-fragment=\"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\"\u003e\u003cspan\u003eTo learn how to use this product, please refer to the\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003e\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/Manual-%20USS-UPVC.pdf\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003euser manual\u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e.\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\n\u003ch2 data-slate-node=\"element\"\u003e\u003cstrong\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-slate-leaf=\"true\" data-sent-id=\"BP90d2vEme\" data-para-id=\"0\" class=\"\"\u003e\u003cspan data-slate-string=\"true\"\u003eSpecifications\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-slate-leaf=\"true\" data-sent-id=\"Bw2DL98jjz\" data-para-id=\"1\" class=\"\"\u003e\u003cspan data-slate-string=\"true\"\u003eModel: USS-MSV473\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-slate-leaf=\"true\" data-sent-id=\"z9ajXPEDJz\" data-para-id=\"2\" class=\"\"\u003e\u003cspan data-slate-string=\"true\"\u003eSize: 1-1\/4\" \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-slate-leaf=\"true\" data-sent-id=\"BaxJd82KJz\" data-para-id=\"3\" class=\"\"\u003e\u003cspan data-slate-string=\"true\"\u003eConnection: Union \u0026amp; Socket End\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-slate-leaf=\"true\" data-sent-id=\"zg5MdYx3Ee\" data-para-id=\"4\" class=\"\"\u003e\u003cspan data-slate-string=\"true\"\u003eSocket Inside Diameter: 42.2mm\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-slate-leaf=\"true\" data-sent-id=\"zrZan5bjLz\" data-para-id=\"5\"\u003e\u003cspan data-slate-string=\"true\"\u003eMaterial: UPVC\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-slate-leaf=\"true\" data-sent-id=\"zlxm27rW1z\" data-para-id=\"7\" class=\"\"\u003e\u003cspan data-slate-string=\"true\"\u003eWorking Voltage: DC 24V\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-slate-leaf=\"true\" data-sent-id=\"BD2jakZR0V\" data-para-id=\"8\" class=\"\"\u003e\u003cspan data-slate-string=\"true\"\u003eMax Power: 15W\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-slate-leaf=\"true\" data-sent-id=\"eLL276pXye\" data-para-id=\"9\" class=\"\"\u003e\u003cspan data-slate-string=\"true\"\u003eMax Torque: 20 N·m\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-slate-leaf=\"true\" data-sent-id=\"Vdompj0KRe\" data-para-id=\"10\" class=\"\"\u003e\u003cspan data-slate-string=\"true\"\u003eMax. Pressure: 232 psi\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\n\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-slate-leaf=\"true\" data-sent-id=\"ebomx1EKpV\" data-para-id=\"11\" class=\"\"\u003e\u003cspan data-slate-string=\"true\"\u003eMedium Temp: 33.8\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-slate-leaf=\"true\" data-sent-id=\"BP90d2vEZe\" data-para-id=\"11\"\u003e\u003cspan data-slate-string=\"true\"\u003e℉ \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-slate-leaf=\"true\" data-sent-id=\"VQaxZEjJ9V\" data-para-id=\"11\"\u003e\u003cspan data-slate-string=\"true\"\u003eto 104\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-slate-leaf=\"true\" data-sent-id=\"Vpgw96Ljre\" data-para-id=\"11\"\u003e\u003cspan data-slate-string=\"true\"\u003e℉\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-slate-leaf=\"true\" data-sent-id=\"VW6NOZM1Ge\" data-para-id=\"12\" class=\"\"\u003e\u003cspan data-slate-string=\"true\"\u003eIP Rating: IP65\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-slate-leaf=\"true\" data-sent-id=\"B89jkb2lpe\" data-para-id=\"13\" class=\"\"\u003e\u003cspan data-slate-string=\"true\"\u003eLife Expectancy: 20,000Cycles\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-slate-leaf=\"true\" data-sent-id=\"V1dK9g4RWe\" data-para-id=\"14\"\u003e\u003cspan data-slate-string=\"true\"\u003eClose\/Open Time: 10-12s\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-slate-leaf=\"true\" data-sent-id=\"Bv2ldwWjPB\" data-para-id=\"15\" class=\"\"\u003e\u003cspan data-slate-string=\"true\"\u003eWiring:  3-wire single-control\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-slate-leaf=\"true\" data-sent-id=\"ejq2ZMajdB\" data-para-id=\"16\" class=\"\"\u003e\u003cspan data-slate-string=\"true\"\u003eManual Function: Yes\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-slate-leaf=\"true\" data-sent-id=\"VNEOo5821e\" data-para-id=\"17\" class=\"\"\u003e\u003cspan data-slate-string=\"true\"\u003eSignal feedback function: No\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\" data-slate-fragment=\"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\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-slate-leaf=\"true\" data-sent-id=\"zn9m4AljMV\" data-para-id=\"18\"\u003e\u003cspan data-slate-string=\"true\"\u003eSeal: EPDM\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-slate-node=\"element\" data-slate-fragment=\"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\"\u003e\u003cspan data-slate-node=\"text\"\u003e\u003cspan data-slate-leaf=\"true\" data-sent-id=\"zn9m4AljMV\" data-para-id=\"18\"\u003e\u003cspan data-slate-string=\"true\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eFactory set:\u003c\/strong\u003e\u003c\/span\u003e The valve is set to CLOSED by default. \u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003eIt is a non-spring return model\u003c\/span\u003e\u003c\/strong\u003e, meaning it does not have a predefined Normally Open (NO) or Normally Closed (NC) state.\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"U.S. Solid","offers":[{"title":"Default Title","offer_id":47911676281087,"sku":"JFMSV00473","price":126.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/1_e994c5be-5ae2-4c5a-ba29-8d05f9297e7b.jpg?v=1758694453"}],"url":"https:\/\/ussolid.com\/collections\/upvc-motorized-ball-valve-html.oembed?page=11","provider":"U.S. Solid","version":"1.0","type":"link"}