{"title":"UPVC","description":"","products":[{"product_id":"1-upvc-motorized-ball-valve-9-36v-ac-dc-plastic-electrical-ball-valve-with-full-port-2-wire-auto-return-normally-closed-html","title":"1\" UPVC Motorized Ball Valve - 9-36V AC\/DC Plastic Electrical Ball Valve with Full Port, 2 Wire Auto Return, Normally Closed","description":"\u003cbody\u003e \n\n\n    \u003cstyle\u003e\n        @media only screen and (max-width: 600px) {\n        }\n    \u003c\/style\u003e\n\n\n    \u003cdiv class=\"desktop-only\"\u003e\n        \u003c!--  --\u003e\n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; line-height: 26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 10px; color: black; font-family: Arial;\"\u003eMotorized ball valves are a vital piece of equipment in numerous applications. This model opens and closes in 6-8 seconds, and remains in its new position while expending almost no energy. This is a key difference between motorized ball valves and many solenoid valves. Most solenoid valves are energized continuously when in a new position, while motorized ball valves expend energy only when changing from open to close, or vice versa.\u003cbr\u003eThe 2 wire auto return model is perfect for situations where the valve needs to be closed in case of power loss. The valve can be energized to open, and left hooked up, with negligible energy used once fully opened. To close, simply shutoff power to the valve. This valve is convenient because it can be operated with a simple on off switch. When on, it will remain open, when turned off (or power is lost for some other reason) the valve automatically closes.\u003c\/p\u003e\n        \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/1.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n             \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n    \u003ctable style=\"border-collapse: collapse;\n                  border: 0px;\n                  width: 100%;\n                  font-family: Arial;\n                  overflow-x: auto;\n                  background-color: #FFFFFF;\"\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"width: 100%;text-align: left;\n                       padding: 0px;\n                       font-size: 16px;\n                       border: 0;\n                       background-color: #FFFFFF;\"\u003e\n                \u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 1\" style=\"width: 100%;height: 100%;\"\u003e\n            \u003c\/td\u003e\n            \u003ctd style=\"width: 100%;text-align: left;\n                       padding: 0px;\n                       font-size: 16px;\n                       border: 0;\n                       background-color: #FFFFFF;\"\u003e\n                \u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 1\" style=\"width: 100%;height: 100%;\"\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/table\u003e\n\u003c\/div\u003e\n          \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e \n \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV00093\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eU.S. Solid\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e2 Wire Auto Return\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eUPVC\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e6 - 8 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e9-36V AC\/DC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e5 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e2 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1°C to 55°C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e50,000 to 80,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eFull\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\/G\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNormally Closed\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1°C to 50°C\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eIP65\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/CE\/CE-EMC.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP65 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYES. The motorized ball valve is made of lead-free UPVC.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n    \u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP65 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP65. The first digit 6 indicates complete dust - tightness. The second digit 5 means protection against water jets from any direction. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/valve%20model.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/JFMSV-User-manual.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n    \u003c\/div\u003e\n    \u003cdiv class=\"mobile-only\"\u003e\n        \u003c!--  --\u003e\n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; line-height:26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 0px; color: black; font-family: Arial;\"\u003eMotorized ball valves are a vital piece of equipment in numerous applications. This model opens and closes in 6-8 seconds, and remains in its new position while expending almost no energy. This is a key difference between motorized ball valves and many solenoid valves. Most solenoid valves are energized continuously when in a new position, while motorized ball valves expend energy only when changing from open to close, or vice versa.\u003cbr\u003eThe 2 wire auto return model is perfect for situations where the valve needs to be closed in case of power loss. The valve can be energized to open, and left hooked up, with negligible energy used once fully opened. To close, simply shutoff power to the valve. This valve is convenient because it can be operated with a simple on off switch. When on, it will remain open, when turned off (or power is lost for some other reason) the valve automatically closes.\u003c\/p\u003e\n            \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/1.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-bottom:10px; margin-top:20px; color: black;\"\u003e\u003cstrong\u003eAPPLICATION\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n    \u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 1\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n    \u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 1\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n\u003c\/div\u003e\n      \u003cp style=\"font-size: 16px; text-align: left; margin-bottom:10px; margin-top:20px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV00093\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eU.S. Solid\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e2 Wire Auto Return\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eUPVC\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e6 - 8 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e9-36V AC\/DC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e5 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e2 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1°C to 55°C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e50,000 to 80,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eFull\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\/G\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNormally Closed\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1°C to 50°C\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eIP65\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/CE\/CE-EMC.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP65 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYES. The motorized ball valve is made of lead-free UPVC.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n    \u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP65 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP65. The first digit 6 indicates complete dust - tightness. The second digit 5 means protection against water jets from any direction. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/valve%20model.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material-APP.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/JFMSV-User-manual.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n    \u003cscript\u003e\n\n        \/\/ (User Agent)\n        const isMobile = window.matchMedia(\"only screen and (max-width: 600px)\").matches;\n        const desktopContent = document.querySelector('.desktop-only');\n        const mobileContent = document.querySelector('.mobile-only');\n\n        if (isMobile) {\n            \/\/ \n            console.log('');\n            \/\/ ，\n            desktopContent.style.display = 'none';\n            mobileContent.style.display = 'block';\n        } else {\n            \/\/ \n            console.log('');            \n            \/\/ ，\n            desktopContent.style.display = 'block';\n            mobileContent.style.display = 'none';\n        }\n    \u003c\/script\u003e\n\n\n\n\u003c\/body\u003e","brand":"U.S. Solid","offers":[{"title":"NPT","offer_id":46918829736191,"sku":"JFMSV00093","price":40.75,"currency_code":"USD","in_stock":true},{"title":"G","offer_id":46918829768959,"sku":"JFMSV00093-G","price":39.79,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/1__72601.1697100473.1280.1280.jpg?v=1731291535"},{"product_id":"1-2-upvc-motorized-ball-valve-9-36v-ac-dc-plastic-electrical-ball-valve-with-full-port-2-wire-auto-return-normally-closed-html","title":"1\/2\" UPVC Motorized Ball Valve - 9-36V AC\/DC Plastic Electrical Ball Valve with Full Port, 2 Wire Auto Return, Normally Closed","description":"\u003cbody\u003e \n\n\n    \u003cstyle\u003e\n        @media only screen and (max-width: 600px) {\n        }\n    \u003c\/style\u003e\n\n\n    \u003cdiv class=\"desktop-only\"\u003e\n        \n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; line-height: 26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 10px; color: black; font-family: Arial;\"\u003eMotorized ball valves are a vital piece of equipment in numerous applications. This model opens and closes in 6-8 seconds, and remains in its new position while expending almost no energy. This is a key difference between motorized ball valves and many solenoid valves. Most solenoid valves are energized continuously when in a new position, while motorized ball valves expend energy only when changing from open to close, or vice versa.\u003cbr\u003eThe 2 wire auto return model is perfect for situations where the valve needs to be closed in case of power loss. The valve can be energized to open, and left hooked up, with negligible energy used once fully opened. To close, simply shutoff power to the valve. This valve is convenient because it can be operated with a simple on off switch. When on, it will remain open, when turned off (or power is lost for some other reason) the valve automatically closes.\u003c\/p\u003e\n        \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/1.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n             \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n    \u003ctable style=\"border-collapse: collapse;\n                  border: 0px;\n                  width: 100%;\n                  font-family: Arial;\n                  overflow-x: auto;\n                  background-color: #FFFFFF;\"\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"width: 100%;text-align: left;\n                       padding: 0px;\n                       font-size: 16px;\n                       border: 0;\n                       background-color: #FFFFFF;\"\u003e\n                \u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 1\/2\" style=\"width: 100%;height: 100%;\"\u003e\n            \u003c\/td\u003e\n            \u003ctd style=\"width: 100%;text-align: left;\n                       padding: 0px;\n                       font-size: 16px;\n                       border: 0;\n                       background-color: #FFFFFF;\"\u003e\n                \u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 1\/2\" style=\"width: 100%;height: 100%;\"\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/table\u003e\n\u003c\/div\u003e\n          \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e \n \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV00091\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eU.S. Solid\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1\/2\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e2 Wire Auto Return\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eUPVC\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e6 - 8 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e9-36V AC\/DC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e5 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e2 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1°C to 55°C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e50,000 to 80,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eFull\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\/G\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNormally Closed\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1°C to 50°C\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eIP65\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/CE\/CE-EMC.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP65 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYES. The motorized ball valve is made of lead-free UPVC.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n    \u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP65 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP65. The first digit 6 indicates complete dust - tightness. The second digit 5 means protection against water jets from any direction. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/valve%20model.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/JFMSV-User-manual.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n    \u003c\/div\u003e\n    \u003cdiv class=\"mobile-only\"\u003e\n        \n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; line-height:26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 0px; color: black; font-family: Arial;\"\u003eMotorized ball valves are a vital piece of equipment in numerous applications. This model opens and closes in 6-8 seconds, and remains in its new position while expending almost no energy. This is a key difference between motorized ball valves and many solenoid valves. Most solenoid valves are energized continuously when in a new position, while motorized ball valves expend energy only when changing from open to close, or vice versa.\u003cbr\u003eThe 2 wire auto return model is perfect for situations where the valve needs to be closed in case of power loss. The valve can be energized to open, and left hooked up, with negligible energy used once fully opened. To close, simply shutoff power to the valve. This valve is convenient because it can be operated with a simple on off switch. When on, it will remain open, when turned off (or power is lost for some other reason) the valve automatically closes.\u003c\/p\u003e\n            \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/1.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-bottom:10px; margin-top:20px; color: black;\"\u003e\u003cstrong\u003eAPPLICATION\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n    \u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 1\/2\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n    \u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 1\/2\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n\u003c\/div\u003e\n      \u003cp style=\"font-size: 16px; text-align: left; margin-bottom:10px; margin-top:20px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV00091\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eU.S. Solid\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1\/2\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e2 Wire Auto Return\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eUPVC\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e6 - 8 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e9-36V AC\/DC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e5 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e2 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1°C to 55°C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e50,000 to 80,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eFull\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\/G\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNormally Closed\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1°C to 50°C\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eIP65\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/CE\/CE-EMC.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP65 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYES. The motorized ball valve is made of lead-free UPVC.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n    \u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP65 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP65. The first digit 6 indicates complete dust - tightness. The second digit 5 means protection against water jets from any direction. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/valve%20model.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material-APP.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/JFMSV-User-manual.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n    \u003cscript\u003e\n\n        \n        const isMobile = window.matchMedia(\"only screen and (max-width: 600px)\").matches;\n        const desktopContent = document.querySelector('.desktop-only');\n        const mobileContent = document.querySelector('.mobile-only');\n\n        if (isMobile) {\n            \n            console.log('');\n           \n            desktopContent.style.display = 'none';\n            mobileContent.style.display = 'block';\n        } else {\n           \n            console.log('');            \n            \n            desktopContent.style.display = 'block';\n            mobileContent.style.display = 'none';\n        }\n    \u003c\/script\u003e\n\n\n\n\u003c\/body\u003e","brand":"U.S. Solid","offers":[{"title":"NPT","offer_id":46892341199103,"sku":"JFMSV00091","price":33.75,"currency_code":"USD","in_stock":true},{"title":"G","offer_id":46892341231871,"sku":"JFMSV00091-G","price":32.79,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/1__04005.1697099836.1280.1280.jpg?v=1731291530"},{"product_id":"3-4-upvc-motorized-ball-valve-9-36v-ac-dc-plastic-electrical-ball-valve-with-full-port-2-wire-auto-return-normally-closed-html","title":"3\/4\" UPVC Motorized Ball Valve - 9-36V AC\/DC Plastic Electrical Ball Valve with Full Port, 2 Wire Auto Return, Normally Closed","description":"\u003cbody\u003e \n\n\n    \u003cstyle\u003e\n        @media only screen and (max-width: 600px) {\n        }\n    \u003c\/style\u003e\n\n\n    \u003cdiv class=\"desktop-only\"\u003e\n        \u003c!--  --\u003e\n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; line-height: 26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 10px; color: black; font-family: Arial;\"\u003eMotorized ball valves are a vital piece of equipment in numerous applications. This model opens and closes in 6-8 seconds, and remains in its new position while expending almost no energy. This is a key difference between motorized ball valves and many solenoid valves. Most solenoid valves are energized continuously when in a new position, while motorized ball valves expend energy only when changing from open to close, or vice versa.\u003cbr\u003eThe 2 wire auto return model is perfect for situations where the valve needs to be closed in case of power loss. The valve can be energized to open, and left hooked up, with negligible energy used once fully opened. To close, simply shutoff power to the valve. This valve is convenient because it can be operated with a simple on off switch. When on, it will remain open, when turned off (or power is lost for some other reason) the valve automatically closes.\u003c\/p\u003e\n        \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/1.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n             \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n    \u003ctable style=\"border-collapse: collapse;\n                  border: 0px;\n                  width: 100%;\n                  font-family: Arial;\n                  overflow-x: auto;\n                  background-color: #FFFFFF;\"\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"width: 100%;text-align: left;\n                       padding: 0px;\n                       font-size: 16px;\n                       border: 0;\n                       background-color: #FFFFFF;\"\u003e\n                \u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 3\/4\" style=\"width: 100%;height: 100%;\"\u003e\n            \u003c\/td\u003e\n            \u003ctd style=\"width: 100%;text-align: left;\n                       padding: 0px;\n                       font-size: 16px;\n                       border: 0;\n                       background-color: #FFFFFF;\"\u003e\n                \u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 3\/4\" style=\"width: 100%;height: 100%;\"\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/table\u003e\n\u003c\/div\u003e\n          \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e \n \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV00092\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eU.S. Solid\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e3\/4\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e2 Wire Auto Return\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eUPVC\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e6 - 8 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e9-36V AC\/DC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e5 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e2 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1°C to 55°C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e50,000 to 80,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eFull\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\/G\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNormally Closed\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1°C to 50°C\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eIP65\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/CE\/CE-EMC.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP65 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYES. The motorized ball valve is made of lead-free UPVC.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n    \u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP65 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP65. The first digit 6 indicates complete dust - tightness. The second digit 5 means protection against water jets from any direction. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/valve%20model.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/JFMSV-User-manual.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n    \u003c\/div\u003e\n    \u003cdiv class=\"mobile-only\"\u003e\n        \u003c!--  --\u003e\n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; line-height:26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 0px; color: black; font-family: Arial;\"\u003eMotorized ball valves are a vital piece of equipment in numerous applications. This model opens and closes in 6-8 seconds, and remains in its new position while expending almost no energy. This is a key difference between motorized ball valves and many solenoid valves. Most solenoid valves are energized continuously when in a new position, while motorized ball valves expend energy only when changing from open to close, or vice versa.\u003cbr\u003eThe 2 wire auto return model is perfect for situations where the valve needs to be closed in case of power loss. The valve can be energized to open, and left hooked up, with negligible energy used once fully opened. To close, simply shutoff power to the valve. This valve is convenient because it can be operated with a simple on off switch. When on, it will remain open, when turned off (or power is lost for some other reason) the valve automatically closes.\u003c\/p\u003e\n            \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/1.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-bottom:10px; margin-top:20px; color: black;\"\u003e\u003cstrong\u003eAPPLICATION\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n    \u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 3\/4\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n    \u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 3\/4\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n\u003c\/div\u003e\n      \u003cp style=\"font-size: 16px; text-align: left; margin-bottom:10px; margin-top:20px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV00092\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eU.S. Solid\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e3\/4\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e2 Wire Auto Return\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eUPVC\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e6 - 8 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e9-36V AC\/DC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e5 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e2 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1°C to 55°C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e50,000 to 80,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eFull\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\/G\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNormally Closed\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1°C to 50°C\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eIP65\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/CE\/CE-EMC.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP65 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYES. The motorized ball valve is made of lead-free UPVC.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n    \u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP65 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP65. The first digit 6 indicates complete dust - tightness. The second digit 5 means protection against water jets from any direction. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/valve%20model.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material-APP.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/JFMSV-User-manual.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n    \u003cscript\u003e\n\n        \/\/ (User Agent)\n        const isMobile = window.matchMedia(\"only screen and (max-width: 600px)\").matches;\n        const desktopContent = document.querySelector('.desktop-only');\n        const mobileContent = document.querySelector('.mobile-only');\n\n        if (isMobile) {\n            \/\/ \n            console.log('');\n            \/\/ ，\n            desktopContent.style.display = 'none';\n            mobileContent.style.display = 'block';\n        } else {\n            \/\/ \n            console.log('');            \n            \/\/ ，\n            desktopContent.style.display = 'block';\n            mobileContent.style.display = 'none';\n        }\n    \u003c\/script\u003e\n\n\n\n\u003c\/body\u003e","brand":"U.S. Solid","offers":[{"title":"NPT","offer_id":46918825148671,"sku":"JFMSV00092","price":36.75,"currency_code":"USD","in_stock":true},{"title":"G","offer_id":46918825181439,"sku":"JFMSV00092-G","price":34.79,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/1__59414.1697100117.1280.1280.jpg?v=1731291541"},{"product_id":"3-4-upvc-motorized-ball-valve-110v-ac-plastic-electrical-ball-valve-with-full-port-2-wire-auto-return-normally-closed-html","title":"3\/4\" UPVC Motorized Ball Valve - 85-265V AC Plastic Electrical Ball Valve with Full Port, 2 Wire Auto Return, Normally Closed","description":"\u003cbody\u003e \n\n\n    \u003cstyle\u003e\n        @media only screen and (max-width: 600px) {\n        }\n    \u003c\/style\u003e\n\n\n    \u003cdiv class=\"desktop-only\"\u003e\n        \n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; line-height: 26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 10px; color: black; font-family: Arial;\"\u003eMotorized ball valves are a vital piece of equipment in numerous applications. This model opens and closes in 6-8 seconds, and remains in its new position while expending almost no energy. This is a key difference between motorized ball valves and many solenoid valves. Most solenoid valves are energized continuously when in a new position, while motorized ball valves expend energy only when changing from open to close, or vice versa.\u003cbr\u003eThe 2 wire auto return model is perfect for situations where the valve needs to be closed in case of power loss. The valve can be energized to open, and left hooked up, with negligible energy used once fully opened. To close, simply shutoff power to the valve. This valve is convenient because it can be operated with a simple on off switch. When on, it will remain open, when turned off (or power is lost for some other reason) the valve automatically closes.\u003c\/p\u003e\n        \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/1.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n             \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n    \u003ctable style=\"border-collapse: collapse;\n                  border: 0px;\n                  width: 100%;\n                  font-family: Arial;\n                  overflow-x: auto;\n                  background-color: #FFFFFF;\"\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"width: 100%;text-align: left;\n                       padding: 0px;\n                       font-size: 16px;\n                       border: 0;\n                       background-color: #FFFFFF;\"\u003e\n                \u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 3\/4\" style=\"width: 100%;height: 100%;\"\u003e\n            \u003c\/td\u003e\n            \u003ctd style=\"width: 100%;text-align: left;\n                       padding: 0px;\n                       font-size: 16px;\n                       border: 0;\n                       background-color: #FFFFFF;\"\u003e\n                \u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 3\/4\" style=\"width: 100%;height: 100%;\"\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/table\u003e\n\u003c\/div\u003e\n          \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e \n \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV00098\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eU.S. Solid\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e3\/4\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e2 Wire Auto Return\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eUPVC\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e6 - 8 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eAC 85-265V\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e10 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e2 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1°C to 55°C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e50,000 to 80,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eFull\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\/G\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNormally Closed\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1°C to 50°C\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eIP65\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/CE.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP65 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYES. The motorized ball valve is made of lead-free UPVC.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n    \u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP65 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP65. The first digit 6 indicates complete dust - tightness. The second digit 5 means protection against water jets from any direction. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/valve%20model.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/JFMSV-User-manual.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n    \u003c\/div\u003e\n    \u003cdiv class=\"mobile-only\"\u003e\n        \n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; line-height:26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 0px; color: black; font-family: Arial;\"\u003eMotorized ball valves are a vital piece of equipment in numerous applications. This model opens and closes in 6-8 seconds, and remains in its new position while expending almost no energy. This is a key difference between motorized ball valves and many solenoid valves. Most solenoid valves are energized continuously when in a new position, while motorized ball valves expend energy only when changing from open to close, or vice versa.\u003cbr\u003eThe 2 wire auto return model is perfect for situations where the valve needs to be closed in case of power loss. The valve can be energized to open, and left hooked up, with negligible energy used once fully opened. To close, simply shutoff power to the valve. This valve is convenient because it can be operated with a simple on off switch. When on, it will remain open, when turned off (or power is lost for some other reason) the valve automatically closes.\u003c\/p\u003e\n            \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/1.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-bottom:10px; margin-top:20px; color: black;\"\u003e\u003cstrong\u003eAPPLICATION\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n    \u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 3\/4\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n    \u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 3\/4\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n\u003c\/div\u003e\n      \u003cp style=\"font-size: 16px; text-align: left; margin-bottom:10px; margin-top:20px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV00098\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eU.S. Solid\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e3\/4\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e2 Wire Auto Return\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eUPVC\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e6 - 8 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eAC 85-265V\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e10 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e2 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1°C to 55°C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e50,000 to 80,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eFull\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\/G\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNormally Closed\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1°C to 50°C\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eIP65\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/CE.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP65 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYES. The motorized ball valve is made of lead-free UPVC.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n    \u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP65 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP65. The first digit 6 indicates complete dust - tightness. The second digit 5 means protection against water jets from any direction. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/valve%20model.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material-APP.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/JFMSV-User-manual.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n    \u003cscript\u003e\n\n        const isMobile = window.matchMedia(\"only screen and (max-width: 600px)\").matches;\n        const desktopContent = document.querySelector('.desktop-only');\n        const mobileContent = document.querySelector('.mobile-only');\n\n        if (isMobile) {\n            \n            console.log('');\n            \n            desktopContent.style.display = 'none';\n            mobileContent.style.display = 'block';\n        } else {\n            \n            console.log('');            \n            \n            desktopContent.style.display = 'block';\n            mobileContent.style.display = 'none';\n        }\n    \u003c\/script\u003e\n\n\n\n\u003c\/body\u003e","brand":"U.S. Solid","offers":[{"title":"NPT","offer_id":46918702170367,"sku":"JFMSV00098","price":41.15,"currency_code":"USD","in_stock":true},{"title":"G","offer_id":46918702203135,"sku":"JFMSV00098-G","price":43.21,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/1__70208.1729581611.1280.1280.jpg?v=1731291597"},{"product_id":"1-upvc-motorized-ball-valve-normally-open-9-36v-ac-dc-plastic-electrical-ball-valve-with-full-port-2-wire-auto-return-html","title":"1\" UPVC Motorized Ball Valve - Normally Open 9-36V AC\/DC Plastic Electrical Ball Valve with Full Port, 2 Wire Auto Return","description":"\u003cbody\u003e \n\n\n    \u003cstyle\u003e\n        @media only screen and (max-width: 600px) {\n        }\n    \u003c\/style\u003e\n\n\n    \u003cdiv class=\"desktop-only\"\u003e\n        \n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; line-height: 26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 10px; color: black; font-family: Arial;\"\u003eMotorized ball valves are a vital piece of equipment in numerous applications. This model opens and closes in 6-8 seconds, and remains in its new position while expending almost no energy. This is a key difference between motorized ball valves and many solenoid valves. Most solenoid valves are energized continuously when in a new position, while motorized ball valves expend energy only when changing from open to close, or vice versa.\u003cbr\u003eThe 2 wire auto return model is perfect for situations where the valve needs to be closed in case of power loss. The valve can be energized to open, and left hooked up, with negligible energy used once fully opened. To close, simply shutoff power to the valve. This valve is convenient because it can be operated with a simple on off switch. When on, it will remain open, when turned off (or power is lost for some other reason) the valve automatically closes.\u003c\/p\u003e\n        \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/1.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n             \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n    \u003ctable style=\"border-collapse: collapse;\n                  border: 0px;\n                  width: 100%;\n                  font-family: Arial;\n                  overflow-x: auto;\n                  background-color: #FFFFFF;\"\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"width: 100%;text-align: left;\n                       padding: 0px;\n                       font-size: 16px;\n                       border: 0;\n                       background-color: #FFFFFF;\"\u003e\n                \u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 1\" style=\"width: 100%;height: 100%;\"\u003e\n            \u003c\/td\u003e\n            \u003ctd style=\"width: 100%;text-align: left;\n                       padding: 0px;\n                       font-size: 16px;\n                       border: 0;\n                       background-color: #FFFFFF;\"\u003e\n                \u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 1\" style=\"width: 100%;height: 100%;\"\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/table\u003e\n\u003c\/div\u003e\n          \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e \n \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV00096\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eU.S. Solid\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e2 Wire Auto Return\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eUPVC\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e6 - 8 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e9-36V AC\/DC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e10 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e2 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1°C to 55°C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e50,000 to 80,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eFull\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\/G\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNormally Open\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1°C to 50°C\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eIP65\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/CE\/CE-EMC.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP65 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYES. The motorized ball valve is made of lead-free UPVC.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n    \u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP65 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP65. The first digit 6 indicates complete dust - tightness. The second digit 5 means protection against water jets from any direction. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/valve%20model.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/JFMSV-User-manual.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n    \u003c\/div\u003e\n    \u003cdiv class=\"mobile-only\"\u003e\n        \n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; line-height:26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 0px; color: black; font-family: Arial;\"\u003eMotorized ball valves are a vital piece of equipment in numerous applications. This model opens and closes in 6-8 seconds, and remains in its new position while expending almost no energy. This is a key difference between motorized ball valves and many solenoid valves. Most solenoid valves are energized continuously when in a new position, while motorized ball valves expend energy only when changing from open to close, or vice versa.\u003cbr\u003eThe 2 wire auto return model is perfect for situations where the valve needs to be closed in case of power loss. The valve can be energized to open, and left hooked up, with negligible energy used once fully opened. To close, simply shutoff power to the valve. This valve is convenient because it can be operated with a simple on off switch. When on, it will remain open, when turned off (or power is lost for some other reason) the valve automatically closes.\u003c\/p\u003e\n            \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/1.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-bottom:10px; margin-top:20px; color: black;\"\u003e\u003cstrong\u003eAPPLICATION\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n    \u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 1\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n    \u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 1\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n\u003c\/div\u003e\n      \u003cp style=\"font-size: 16px; text-align: left; margin-bottom:10px; margin-top:20px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV00096\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eU.S. Solid\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e2 Wire Auto Return\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eUPVC\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e6 - 8 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e9-36V AC\/DC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e10 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e2 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1°C to 55°C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e50,000 to 80,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eFull\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\/G\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNormally Open\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1°C to 50°C\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eIP65\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/CE\/CE-EMC.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP65 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYES. The motorized ball valve is made of lead-free UPVC.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n    \u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP65 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP65. The first digit 6 indicates complete dust - tightness. The second digit 5 means protection against water jets from any direction. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/valve%20model.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material-APP.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/JFMSV-User-manual.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n    \u003cscript\u003e\n\n        \n        const isMobile = window.matchMedia(\"only screen and (max-width: 600px)\").matches;\n        const desktopContent = document.querySelector('.desktop-only');\n        const mobileContent = document.querySelector('.mobile-only');\n\n        if (isMobile) {\n            \n            console.log('');\n            \n            desktopContent.style.display = 'none';\n            mobileContent.style.display = 'block';\n        } else {\n           \n            console.log('');            \n            \n            desktopContent.style.display = 'block';\n            mobileContent.style.display = 'none';\n        }\n    \u003c\/script\u003e\n\n\n\n\u003c\/body\u003e","brand":"U.S. Solid","offers":[{"title":"NPT","offer_id":46918700073215,"sku":"JFMSV00096","price":43.59,"currency_code":"USD","in_stock":true},{"title":"G","offer_id":46918700105983,"sku":"JFMSV00096-G","price":41.19,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/1__54261.1729581164.1280.1280.jpg?v=1731291600"},{"product_id":"1-2-upvc-motorized-ball-valve-normally-open-9-36v-ac-dc-plastic-electrical-ball-valve-with-full-port-2-wire-auto-return-html","title":"1\/2\" UPVC Motorized Ball Valve - Normally Open 9-36V AC\/DC Plastic Electrical Ball Valve with Full Port, 2 Wire Auto Return","description":"\u003cbody\u003e \n\n\n    \u003cstyle\u003e\n        @media only screen and (max-width: 600px) {\n        }\n    \u003c\/style\u003e\n\n\n    \u003cdiv class=\"desktop-only\"\u003e\n       \n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; line-height: 26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 10px; color: black; font-family: Arial;\"\u003eMotorized ball valves are a vital piece of equipment in numerous applications. This model opens and closes in 6-8 seconds, and remains in its new position while expending almost no energy. This is a key difference between motorized ball valves and many solenoid valves. Most solenoid valves are energized continuously when in a new position, while motorized ball valves expend energy only when changing from open to close, or vice versa.\u003cbr\u003eThe 2 wire auto return model is perfect for situations where the valve needs to be closed in case of power loss. The valve can be energized to open, and left hooked up, with negligible energy used once fully opened. To close, simply shutoff power to the valve. This valve is convenient because it can be operated with a simple on off switch. When on, it will remain open, when turned off (or power is lost for some other reason) the valve automatically closes.\u003c\/p\u003e\n        \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/1.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n             \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n    \u003ctable style=\"border-collapse: collapse;\n                  border: 0px;\n                  width: 100%;\n                  font-family: Arial;\n                  overflow-x: auto;\n                  background-color: #FFFFFF;\"\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"width: 100%;text-align: left;\n                       padding: 0px;\n                       font-size: 16px;\n                       border: 0;\n                       background-color: #FFFFFF;\"\u003e\n                \u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 1\/2\" style=\"width: 100%;height: 100%;\"\u003e\n            \u003c\/td\u003e\n            \u003ctd style=\"width: 100%;text-align: left;\n                       padding: 0px;\n                       font-size: 16px;\n                       border: 0;\n                       background-color: #FFFFFF;\"\u003e\n                \u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 1\/2\" style=\"width: 100%;height: 100%;\"\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/table\u003e\n\u003c\/div\u003e\n          \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e \n \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV00094\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eU.S. Solid\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1\/2\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e2 Wire Auto Return\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eUPVC\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e6 - 8 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e9-36V AC\/DC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e5 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e2 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1°C to 55°C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e50,000 to 80,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eFull\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\/G\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNormally Open\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1°C to 50°C\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eIP65\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/CE\/CE-EMC.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP65 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYES. The motorized ball valve is made of lead-free UPVC.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n    \u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP65 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP65. The first digit 6 indicates complete dust - tightness. The second digit 5 means protection against water jets from any direction. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/valve%20model.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/JFMSV-User-manual.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n    \u003c\/div\u003e\n    \u003cdiv class=\"mobile-only\"\u003e\n        \n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; line-height:26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 0px; color: black; font-family: Arial;\"\u003eMotorized ball valves are a vital piece of equipment in numerous applications. This model opens and closes in 6-8 seconds, and remains in its new position while expending almost no energy. This is a key difference between motorized ball valves and many solenoid valves. Most solenoid valves are energized continuously when in a new position, while motorized ball valves expend energy only when changing from open to close, or vice versa.\u003cbr\u003eThe 2 wire auto return model is perfect for situations where the valve needs to be closed in case of power loss. The valve can be energized to open, and left hooked up, with negligible energy used once fully opened. To close, simply shutoff power to the valve. This valve is convenient because it can be operated with a simple on off switch. When on, it will remain open, when turned off (or power is lost for some other reason) the valve automatically closes.\u003c\/p\u003e\n            \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/1.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-bottom:10px; margin-top:20px; color: black;\"\u003e\u003cstrong\u003eAPPLICATION\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n    \u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 1\/2\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n    \u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 1\/2\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n\u003c\/div\u003e\n      \u003cp style=\"font-size: 16px; text-align: left; margin-bottom:10px; margin-top:20px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV00094\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eU.S. Solid\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1\/2\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e2 Wire Auto Return\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eUPVC\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e6 - 8 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e9-36V AC\/DC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e5 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e2 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1°C to 55°C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e50,000 to 80,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eFull\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\/G\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNormally Open\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1°C to 50°C\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eIP65\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/CE\/CE-EMC.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP65 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYES. The motorized ball valve is made of lead-free UPVC.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n    \u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP65 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP65. The first digit 6 indicates complete dust - tightness. The second digit 5 means protection against water jets from any direction. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/valve%20model.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material-APP.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/JFMSV-User-manual.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n    \u003cscript\u003e\n\n       \n        const isMobile = window.matchMedia(\"only screen and (max-width: 600px)\").matches;\n        const desktopContent = document.querySelector('.desktop-only');\n        const mobileContent = document.querySelector('.mobile-only');\n\n        if (isMobile) {\n           \n            console.log('');\n           \n            desktopContent.style.display = 'none';\n            mobileContent.style.display = 'block';\n        } else {\n           \n            console.log('');            \n            \n            desktopContent.style.display = 'block';\n            mobileContent.style.display = 'none';\n        }\n    \u003c\/script\u003e\n\n\n\n\u003c\/body\u003e","brand":"U.S. Solid","offers":[{"title":"NPT","offer_id":46918697419007,"sku":"JFMSV00094","price":34.59,"currency_code":"USD","in_stock":true},{"title":"G","offer_id":46918697451775,"sku":"JFMSV00094-G","price":32.19,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/1__12754.1729581017.1280.1280.jpg?v=1731291601"},{"product_id":"1-2-upvc-motorized-ball-valve-110v-ac-plastic-electrical-ball-valve-with-full-port-2-wire-auto-return-normally-closed-html","title":"1\/2\" UPVC Motorized Ball Valve - 85-265V AC Plastic Electrical Ball Valve with Full Port, 2 Wire Auto Return, Normally Closed","description":"\u003cbody\u003e \n\n\n    \u003cstyle\u003e\n        @media only screen and (max-width: 600px) {\n        }\n    \u003c\/style\u003e\n\n\n    \u003cdiv class=\"desktop-only\"\u003e\n        \n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; line-height: 26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 10px; color: black; font-family: Arial;\"\u003eMotorized ball valves are a vital piece of equipment in numerous applications. This model opens and closes in 6-8 seconds, and remains in its new position while expending almost no energy. This is a key difference between motorized ball valves and many solenoid valves. Most solenoid valves are energized continuously when in a new position, while motorized ball valves expend energy only when changing from open to close, or vice versa.\u003cbr\u003eThe 2 wire auto return model is perfect for situations where the valve needs to be closed in case of power loss. The valve can be energized to open, and left hooked up, with negligible energy used once fully opened. To close, simply shutoff power to the valve. This valve is convenient because it can be operated with a simple on off switch. When on, it will remain open, when turned off (or power is lost for some other reason) the valve automatically closes.\u003c\/p\u003e\n        \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/1.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n             \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n    \u003ctable style=\"border-collapse: collapse;\n                  border: 0px;\n                  width: 100%;\n                  font-family: Arial;\n                  overflow-x: auto;\n                  background-color: #FFFFFF;\"\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"width: 100%;text-align: left;\n                       padding: 0px;\n                       font-size: 16px;\n                       border: 0;\n                       background-color: #FFFFFF;\"\u003e\n                \u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 1\/2\" style=\"width: 100%;height: 100%;\"\u003e\n            \u003c\/td\u003e\n            \u003ctd style=\"width: 100%;text-align: left;\n                       padding: 0px;\n                       font-size: 16px;\n                       border: 0;\n                       background-color: #FFFFFF;\"\u003e\n                \u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 1\/2\" style=\"width: 100%;height: 100%;\"\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/table\u003e\n\u003c\/div\u003e\n          \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e \n \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV00097\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eU.S. Solid\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1\/2\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e2 Wire Auto Return\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eUPVC\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e6 - 8 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eAC 85-265V\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e10 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e2 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1°C to 55°C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e50,000 to 80,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eFull\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\/G\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNormally Closed\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1°C to 50°C\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eIP65\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/CE.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP65 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYES. The motorized ball valve is made of lead-free UPVC.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n    \u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP65 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP65. The first digit 6 indicates complete dust - tightness. The second digit 5 means protection against water jets from any direction. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/valve%20model.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/JFMSV-User-manual.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n    \u003c\/div\u003e\n    \u003cdiv class=\"mobile-only\"\u003e\n       \n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; line-height:26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 0px; color: black; font-family: Arial;\"\u003eMotorized ball valves are a vital piece of equipment in numerous applications. This model opens and closes in 6-8 seconds, and remains in its new position while expending almost no energy. This is a key difference between motorized ball valves and many solenoid valves. Most solenoid valves are energized continuously when in a new position, while motorized ball valves expend energy only when changing from open to close, or vice versa.\u003cbr\u003eThe 2 wire auto return model is perfect for situations where the valve needs to be closed in case of power loss. The valve can be energized to open, and left hooked up, with negligible energy used once fully opened. To close, simply shutoff power to the valve. This valve is convenient because it can be operated with a simple on off switch. When on, it will remain open, when turned off (or power is lost for some other reason) the valve automatically closes.\u003c\/p\u003e\n            \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/1.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-bottom:10px; margin-top:20px; color: black;\"\u003e\u003cstrong\u003eAPPLICATION\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n    \u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 1\/2\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n    \u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 1\/2\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n\u003c\/div\u003e\n      \u003cp style=\"font-size: 16px; text-align: left; margin-bottom:10px; margin-top:20px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV00097\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eU.S. Solid\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1\/2\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e2 Wire Auto Return\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eUPVC\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e6 - 8 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eAC 85-265V\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e10 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e2 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1°C to 55°C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e50,000 to 80,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eFull\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\/G\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNormally Closed\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1°C to 50°C\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eIP65\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/CE.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP65 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYES. The motorized ball valve is made of lead-free UPVC.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n    \u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP65 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP65. The first digit 6 indicates complete dust - tightness. The second digit 5 means protection against water jets from any direction. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/valve%20model.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material-APP.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/JFMSV-User-manual.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n    \u003cscript\u003e\n\n        \n        const isMobile = window.matchMedia(\"only screen and (max-width: 600px)\").matches;\n        const desktopContent = document.querySelector('.desktop-only');\n        const mobileContent = document.querySelector('.mobile-only');\n\n        if (isMobile) {\n           \n            console.log('');\n           \n            desktopContent.style.display = 'none';\n            mobileContent.style.display = 'block';\n        } else {\n           \n            console.log('');            \n            \n            desktopContent.style.display = 'block';\n            mobileContent.style.display = 'none';\n        }\n    \u003c\/script\u003e\n\n\n\n\u003c\/body\u003e","brand":"U.S. Solid","offers":[{"title":"NPT","offer_id":46918696108287,"sku":"JFMSV00097","price":40.69,"currency_code":"USD","in_stock":true},{"title":"G","offer_id":46918696141055,"sku":"JFMSV00097-G","price":39.49,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/1__76387.1729578916.1280.1280.jpg?v=1731291601"},{"product_id":"1-upvc-motorized-ball-valve-110v-ac-plastic-electrical-ball-valve-with-full-port-2-wire-auto-return-normally-closed-html","title":"1\" UPVC Motorized Ball Valve - 85-265V AC Plastic Electrical Ball Valve with Full Port, 2 Wire Auto Return, Normally Closed","description":"\u003cbody\u003e \n\n\n    \u003cstyle\u003e\n        @media only screen and (max-width: 600px) {\n        }\n    \u003c\/style\u003e\n\n\n    \u003cdiv class=\"desktop-only\"\u003e\n       \n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; line-height: 26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 10px; color: black; font-family: Arial;\"\u003eMotorized ball valves are a vital piece of equipment in numerous applications. This model opens and closes in 6-8 seconds, and remains in its new position while expending almost no energy. This is a key difference between motorized ball valves and many solenoid valves. Most solenoid valves are energized continuously when in a new position, while motorized ball valves expend energy only when changing from open to close, or vice versa.\u003cbr\u003eThe 2 wire auto return model is perfect for situations where the valve needs to be closed in case of power loss. The valve can be energized to open, and left hooked up, with negligible energy used once fully opened. To close, simply shutoff power to the valve. This valve is convenient because it can be operated with a simple on off switch. When on, it will remain open, when turned off (or power is lost for some other reason) the valve automatically closes.\u003c\/p\u003e\n        \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/1.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n             \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n    \u003ctable style=\"border-collapse: collapse;\n                  border: 0px;\n                  width: 100%;\n                  font-family: Arial;\n                  overflow-x: auto;\n                  background-color: #FFFFFF;\"\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"width: 100%;text-align: left;\n                       padding: 0px;\n                       font-size: 16px;\n                       border: 0;\n                       background-color: #FFFFFF;\"\u003e\n                \u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 1\" style=\"width: 100%;height: 100%;\"\u003e\n            \u003c\/td\u003e\n            \u003ctd style=\"width: 100%;text-align: left;\n                       padding: 0px;\n                       font-size: 16px;\n                       border: 0;\n                       background-color: #FFFFFF;\"\u003e\n                \u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 1\" style=\"width: 100%;height: 100%;\"\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/table\u003e\n\u003c\/div\u003e\n          \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e \n \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV00099\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eU.S. Solid\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e2 Wire Auto Return\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eUPVC\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e6 - 8 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eAC 85-265V\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e10 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e2 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1°C to 55°C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e50,000 to 80,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eFull\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\/G\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNormally Closed\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1°C to 50°C\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eIP65\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/CE.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP65 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYES. The motorized ball valve is made of lead-free UPVC.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n    \u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP65 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP65. The first digit 6 indicates complete dust - tightness. The second digit 5 means protection against water jets from any direction. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/valve%20model.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/JFMSV-User-manual.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n    \u003c\/div\u003e\n    \u003cdiv class=\"mobile-only\"\u003e\n        \u003c!--  --\u003e\n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; line-height:26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 0px; color: black; font-family: Arial;\"\u003eMotorized ball valves are a vital piece of equipment in numerous applications. This model opens and closes in 6-8 seconds, and remains in its new position while expending almost no energy. This is a key difference between motorized ball valves and many solenoid valves. Most solenoid valves are energized continuously when in a new position, while motorized ball valves expend energy only when changing from open to close, or vice versa.\u003cbr\u003eThe 2 wire auto return model is perfect for situations where the valve needs to be closed in case of power loss. The valve can be energized to open, and left hooked up, with negligible energy used once fully opened. To close, simply shutoff power to the valve. This valve is convenient because it can be operated with a simple on off switch. When on, it will remain open, when turned off (or power is lost for some other reason) the valve automatically closes.\u003c\/p\u003e\n            \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/1.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-bottom:10px; margin-top:20px; color: black;\"\u003e\u003cstrong\u003eAPPLICATION\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n    \u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 1\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n    \u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 1\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n\u003c\/div\u003e\n      \u003cp style=\"font-size: 16px; text-align: left; margin-bottom:10px; margin-top:20px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV00099\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eU.S. Solid\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e2 Wire Auto Return\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eUPVC\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e6 - 8 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eAC 85-265V\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e10 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e2 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1°C to 55°C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e50,000 to 80,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eFull\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\/G\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNormally Closed\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1°C to 50°C\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eIP65\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/CE.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP65 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYES. The motorized ball valve is made of lead-free UPVC.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n    \u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP65 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP65. The first digit 6 indicates complete dust - tightness. The second digit 5 means protection against water jets from any direction. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/valve%20model.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material-APP.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/JFMSV-User-manual.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n    \u003cscript\u003e\n\n        \/\/ (User Agent)\n        const isMobile = window.matchMedia(\"only screen and (max-width: 600px)\").matches;\n        const desktopContent = document.querySelector('.desktop-only');\n        const mobileContent = document.querySelector('.mobile-only');\n\n        if (isMobile) {\n            \/\/ \n            console.log('');\n            \/\/ ，\n            desktopContent.style.display = 'none';\n            mobileContent.style.display = 'block';\n        } else {\n            \/\/ \n            console.log('');            \n            \/\/ ，\n            desktopContent.style.display = 'block';\n            mobileContent.style.display = 'none';\n        }\n    \u003c\/script\u003e\n\n\n\n\u003c\/body\u003e","brand":"U.S. Solid","offers":[{"title":"NPT","offer_id":46918693028095,"sku":"JFMSV00099","price":48.69,"currency_code":"USD","in_stock":true},{"title":"G","offer_id":46918693060863,"sku":"JFMSV00099-G","price":45.49,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/1__76387.1729578916.1280.1280_128f6a80-5e1f-4c1a-a134-e7e9a2027b0c.jpg?v=1766544741"},{"product_id":"3-4-upvc-motorized-ball-valve-normally-open-9-36v-ac-dc-plastic-electrical-ball-valve-with-full-port-2-wire-auto-return-html","title":"3\/4\" UPVC Motorized Ball Valve - Normally Open 9-36V AC\/DC Plastic Electrical Ball Valve with Full Port, 2 Wire Auto Return","description":"\u003cbody\u003e \n\n\n    \u003cstyle\u003e\n        @media only screen and (max-width: 600px) {\n        }\n    \u003c\/style\u003e\n\n\n    \u003cdiv class=\"desktop-only\"\u003e\n       \n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; line-height: 26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 10px; color: black; font-family: Arial;\"\u003eMotorized ball valves are a vital piece of equipment in numerous applications. This model opens and closes in 6-8 seconds, and remains in its new position while expending almost no energy. This is a key difference between motorized ball valves and many solenoid valves. Most solenoid valves are energized continuously when in a new position, while motorized ball valves expend energy only when changing from open to close, or vice versa.\u003cbr\u003eThe 2 wire auto return model is perfect for situations where the valve needs to be closed in case of power loss. The valve can be energized to open, and left hooked up, with negligible energy used once fully opened. To close, simply shutoff power to the valve. This valve is convenient because it can be operated with a simple on off switch. When on, it will remain open, when turned off (or power is lost for some other reason) the valve automatically closes.\u003c\/p\u003e\n        \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/1.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n             \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n    \u003ctable style=\"border-collapse: collapse;\n                  border: 0px;\n                  width: 100%;\n                  font-family: Arial;\n                  overflow-x: auto;\n                  background-color: #FFFFFF;\"\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"width: 100%;text-align: left;\n                       padding: 0px;\n                       font-size: 16px;\n                       border: 0;\n                       background-color: #FFFFFF;\"\u003e\n                \u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 3\/4\" style=\"width: 100%;height: 100%;\"\u003e\n            \u003c\/td\u003e\n            \u003ctd style=\"width: 100%;text-align: left;\n                       padding: 0px;\n                       font-size: 16px;\n                       border: 0;\n                       background-color: #FFFFFF;\"\u003e\n                \u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 3\/4\" style=\"width: 100%;height: 100%;\"\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/table\u003e\n\u003c\/div\u003e\n          \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e \n \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV00095\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eU.S. Solid\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e3\/4\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e2 Wire Auto Return\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eUPVC\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e6 - 8 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e9-36V AC\/DC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e10 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e2 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1°C to 55°C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e50,000 to 80,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eFull\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\/G\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNormally Open\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1°C to 50°C\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eIP65\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/CE\/CE-EMC.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP65 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYES. The motorized ball valve is made of lead-free UPVC.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n    \u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP65 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP65. The first digit 6 indicates complete dust - tightness. The second digit 5 means protection against water jets from any direction. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/valve%20model.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/JFMSV-User-manual.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n    \u003c\/div\u003e\n    \u003cdiv class=\"mobile-only\"\u003e\n        \n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; line-height:26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 0px; color: black; font-family: Arial;\"\u003eMotorized ball valves are a vital piece of equipment in numerous applications. This model opens and closes in 6-8 seconds, and remains in its new position while expending almost no energy. This is a key difference between motorized ball valves and many solenoid valves. Most solenoid valves are energized continuously when in a new position, while motorized ball valves expend energy only when changing from open to close, or vice versa.\u003cbr\u003eThe 2 wire auto return model is perfect for situations where the valve needs to be closed in case of power loss. The valve can be energized to open, and left hooked up, with negligible energy used once fully opened. To close, simply shutoff power to the valve. This valve is convenient because it can be operated with a simple on off switch. When on, it will remain open, when turned off (or power is lost for some other reason) the valve automatically closes.\u003c\/p\u003e\n            \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/1.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-bottom:10px; margin-top:20px; color: black;\"\u003e\u003cstrong\u003eAPPLICATION\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n    \u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 3\/4\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n    \u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 3\/4\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n\u003c\/div\u003e\n      \u003cp style=\"font-size: 16px; text-align: left; margin-bottom:10px; margin-top:20px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV00095\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eU.S. Solid\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e3\/4\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e2 Wire Auto Return\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eUPVC\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e6 - 8 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e9-36V AC\/DC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e10 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e2 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1°C to 55°C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e50,000 to 80,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eFull\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\/G\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNormally Open\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1°C to 50°C\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eIP65\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/CE\/CE-EMC.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP65 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYES. The motorized ball valve is made of lead-free UPVC.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n    \u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP65 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP65. The first digit 6 indicates complete dust - tightness. The second digit 5 means protection against water jets from any direction. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/valve%20model.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material-APP.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/JFMSV-User-manual.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n    \u003cscript\u003e\n\n       \n        const isMobile = window.matchMedia(\"only screen and (max-width: 600px)\").matches;\n        const desktopContent = document.querySelector('.desktop-only');\n        const mobileContent = document.querySelector('.mobile-only');\n\n        if (isMobile) {\n      \n            console.log('');\n           \n            desktopContent.style.display = 'none';\n            mobileContent.style.display = 'block';\n        } else {\n            \n            console.log('');            \n            \n            desktopContent.style.display = 'block';\n            mobileContent.style.display = 'none';\n        }\n    \u003c\/script\u003e\n\n\n\n\u003c\/body\u003e","brand":"U.S. Solid","offers":[{"title":"NPT","offer_id":46918686081279,"sku":"JFMSV00095","price":36.59,"currency_code":"USD","in_stock":true},{"title":"G","offer_id":46918686114047,"sku":"JFMSV00095-G","price":35.19,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/1__38110.1729580791.1280.1280.jpg?v=1731291609"},{"product_id":"1-2-upvc-motorized-ball-valve-9-36v-ac-dc-plastic-electrical-ball-valve-with-standard-port-2-wire-auto-return-normally-closed-html","title":"1\/2\" UPVC Motorized Ball Valve - 9-24V AC\/DC Plastic Electrical Ball Valve with Standard Port, 2 Wire Auto Return, Normally Closed","description":"\u003cbody\u003e \n\n\n    \u003cstyle\u003e\n        @media only screen and (max-width: 600px) {\n        }\n    \u003c\/style\u003e\n\n\n    \u003cdiv class=\"desktop-only\"\u003e\n        \n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; line-height: 26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 10px; color: black; font-family: Arial;\"\u003eMotorized ball valves are a vital piece of equipment in numerous applications. This model opens and closes in 6-8 seconds, and remains in its new position while expending almost no energy. This is a key difference between motorized ball valves and many solenoid valves. Most solenoid valves are energized continuously when in a new position, while motorized ball valves expend energy only when changing from open to close, or vice versa.\u003cbr\u003eThe 2 wire auto return model is perfect for situations where the valve needs to be closed in case of power loss. The valve can be energized to open, and left hooked up, with negligible energy used once fully opened. To close, simply shutoff power to the valve. This valve is convenient because it can be operated with a simple on off switch. When on, it will remain open, when turned off (or power is lost for some other reason) the valve automatically closes.\u003c\/p\u003e\n        \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/1.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n             \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n    \u003ctable style=\"border-collapse: collapse;\n                  border: 0px;\n                  width: 100%;\n                  font-family: Arial;\n                  overflow-x: auto;\n                  background-color: #FFFFFF;\"\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"width: 100%;text-align: left;\n                       padding: 0px;\n                       font-size: 16px;\n                       border: 0;\n                       background-color: #FFFFFF;\"\u003e\n                \u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 1\/2\" style=\"width: 100%;height: 100%;\"\u003e\n            \u003c\/td\u003e\n            \u003ctd style=\"width: 100%;text-align: left;\n                       padding: 0px;\n                       font-size: 16px;\n                       border: 0;\n                       background-color: #FFFFFF;\"\u003e\n                \u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 1\/2\" style=\"width: 100%;height: 100%;\"\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/table\u003e\n\u003c\/div\u003e\n          \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e \n \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV00411\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eU.S. Solid\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1\/2\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e2 Wire Auto Return\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eUPVC\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e6 - 8 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e9-24V AC\/DC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e5 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e6 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e0°C to 60°C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e80,000 to 100,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eFull\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\/G\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNormally Closed\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e-10°C to 40°C\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eIP65\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/CE\/CE-EMC.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP65 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYES. The motorized ball valve is made of lead-free Polyvinyl Chloride and is NSF certified.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n    \u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP65 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP65. The first digit 6 indicates complete dust - tightness. The second digit 5 means protection against water jets from any direction. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/valve%20model.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/JFMSV-User-manual.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n    \u003c\/div\u003e\n    \u003cdiv class=\"mobile-only\"\u003e\n        \n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; line-height:26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 0px; color: black; font-family: Arial;\"\u003eMotorized ball valves are a vital piece of equipment in numerous applications. This model opens and closes in 6-8 seconds, and remains in its new position while expending almost no energy. This is a key difference between motorized ball valves and many solenoid valves. Most solenoid valves are energized continuously when in a new position, while motorized ball valves expend energy only when changing from open to close, or vice versa.\u003cbr\u003eThe 2 wire auto return model is perfect for situations where the valve needs to be closed in case of power loss. The valve can be energized to open, and left hooked up, with negligible energy used once fully opened. To close, simply shutoff power to the valve. This valve is convenient because it can be operated with a simple on off switch. When on, it will remain open, when turned off (or power is lost for some other reason) the valve automatically closes.\u003c\/p\u003e\n            \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/1.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-bottom:10px; margin-top:20px; color: black;\"\u003e\u003cstrong\u003eAPPLICATION\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n    \u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 1\/2\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n    \u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 1\/2\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n\u003c\/div\u003e\n      \u003cp style=\"font-size: 16px; text-align: left; margin-bottom:10px; margin-top:20px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV00411\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eU.S. Solid\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1\/2\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e2 Wire Auto Return\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eUPVC\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e6 - 8 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e9-24V AC\/DC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e5 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e6 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e0°C to 60°C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e80,000 to 100,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eFull\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\/G\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNormally Closed\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e-10°C to 40°C\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eIP65\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/CE\/CE-EMC.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP65 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYES. The motorized ball valve is made of lead-free Polyvinyl Chloride and is NSF certified.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n    \u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP65 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP65. The first digit 6 indicates complete dust - tightness. The second digit 5 means protection against water jets from any direction. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/valve%20model.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material-APP.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/JFMSV-User-manual.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n    \u003cscript\u003e\n\n       \n        const isMobile = window.matchMedia(\"only screen and (max-width: 600px)\").matches;\n        const desktopContent = document.querySelector('.desktop-only');\n        const mobileContent = document.querySelector('.mobile-only');\n\n        if (isMobile) {\n            \n            console.log('');\n            \n            desktopContent.style.display = 'none';\n            mobileContent.style.display = 'block';\n        } else {\n           \n            console.log('');            \n           \n            desktopContent.style.display = 'block';\n            mobileContent.style.display = 'none';\n        }\n    \u003c\/script\u003e\n\n\n\n\u003c\/body\u003e","brand":"U.S. Solid","offers":[{"title":"NPT","offer_id":46918682378495,"sku":"JFMSV00411","price":36.07,"currency_code":"USD","in_stock":true},{"title":"G","offer_id":46918682411263,"sku":"JFMSV00411-G","price":33.97,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/1__37287.1729564200.1280.1280.jpg?v=1731291624"},{"product_id":"1-upvc-motorized-ball-valve-85-265v-ac-plastic-electrical-ball-valve-with-standard-port-2-wire-auto-return-normally-closed","title":"1\" UPVC Motorized Ball Valve - 85-265V AC Plastic Electrical Ball Valve with Standard Port, 2 Wire Auto Return, Normally Closed","description":"\u003cbody\u003e \n\n\n    \u003cstyle\u003e\n        @media only screen and (max-width: 600px) {\n        }\n    \u003c\/style\u003e\n\n\n    \u003cdiv class=\"desktop-only\"\u003e\n        \n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; line-height: 26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 10px; color: black; font-family: Arial;\"\u003eMotorized ball valves are a vital piece of equipment in numerous applications. This model Closes and closes in 6-8 seconds, and remains in its new position while expending almost no energy. This is a key difference between motorized ball valves and many solenoid valves. Most solenoid valves are energized continuously when in a new position, while motorized ball valves expend energy only when changing from Closed to close, or vice versa.\u003cbr\u003eThe 2 wire auto return model is perfect for situations where the valve needs to be Closed in case of power loss. The valve can be energized to Closed, and left hooked up, with negligible energy used once fully Closed. To close, simply shutoff power to the valve. This valve is convenient because it can be operated with a simple on off switch. When on, it will remain Closed, when turned off (or power is lost for some other reason) the valve automatically closes.\u003c\/p\u003e\n        \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/1.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n             \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n    \u003ctable style=\"border-collapse: collapse;\n                  border: 0px;\n                  width: 100%;\n                  font-family: Arial;\n                  overflow-x: auto;\n                  background-color: #FFFFFF;\"\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"width: 100%;text-align: left;\n                       padding: 0px;\n                       font-size: 16px;\n                       border: 0;\n                       background-color: #FFFFFF;\"\u003e\n                \u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 1\" style=\"width: 100%;height: 100%;\"\u003e\n            \u003c\/td\u003e\n            \u003ctd style=\"width: 100%;text-align: left;\n                       padding: 0px;\n                       font-size: 16px;\n                       border: 0;\n                       background-color: #FFFFFF;\"\u003e\n                \u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 1\" style=\"width: 100%;height: 100%;\"\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/table\u003e\n\u003c\/div\u003e\n          \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e \n \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV00419\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eU.S. Solid\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e2 Wire Auto Return\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eUPVC\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e6 - 8 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eAC 85-265V\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e5 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e6 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e0°C to 60°C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e80,000 to 100,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eStandard\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\/G\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNormally Closed\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e-10°C to 40°C\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eIP65\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/CE.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n       \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP65 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYES. The motorized ball valve is made of lead-free Polyvinyl Chloride and is NSF certified.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n    \u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                 \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP65 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP65. The first digit 6 indicates complete dust - tightness. The second digit 5 means protection against water jets from any direction. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e\n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/valve%20model.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/JFMSV-User-manual.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n    \u003c\/div\u003e\n    \u003cdiv class=\"mobile-only\"\u003e\n       \n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; line-height:26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 0px; color: black; font-family: Arial;\"\u003eMotorized ball valves are a vital piece of equipment in numerous applications. This model Closes and closes in 6-8 seconds, and remains in its new position while expending almost no energy. This is a key difference between motorized ball valves and many solenoid valves. Most solenoid valves are energized continuously when in a new position, while motorized ball valves expend energy only when changing from Closed to close, or vice versa.\u003cbr\u003eThe 2 wire auto return model is perfect for situations where the valve needs to be Closed in case of power loss. The valve can be energized to Closed, and left hooked up, with negligible energy used once fully Closed. To close, simply shutoff power to the valve. This valve is convenient because it can be operated with a simple on off switch. When on, it will remain Closed, when turned off (or power is lost for some other reason) the valve automatically closes.\u003c\/p\u003e\n            \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/1.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-bottom:10px; margin-top:20px; color: black;\"\u003e\u003cstrong\u003eAPPLICATION\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n    \u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 1\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n    \u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 1\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n\u003c\/div\u003e\n      \u003cp style=\"font-size: 16px; text-align: left; margin-bottom:10px; margin-top:20px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV00419\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eU.S. Solid\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e2 Wire Auto Return\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eUPVC\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e6 - 8 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eAC 85-265V\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e5 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e6 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e0°C to 60°C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e80,000 to 100,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eStandard\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\/G\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNormally Closed\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e-10°C to 40°C\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eIP65\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/CE.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n       \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP65 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYES. The motorized ball valve is made of lead-free Polyvinyl Chloride and is NSF certified.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n    \u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                 \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP65 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP65. The first digit 6 indicates complete dust - tightness. The second digit 5 means protection against water jets from any direction. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/valve%20model.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material-APP.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/JFMSV-User-manual.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n    \u003cscript\u003e\n\n        \n        const isMobile = window.matchMedia(\"only screen and (max-width: 600px)\").matches;\n        const desktopContent = document.querySelector('.desktop-only');\n        const mobileContent = document.querySelector('.mobile-only');\n\n        if (isMobile) {\n          \n            console.log('');\n            \n            desktopContent.style.display = 'none';\n            mobileContent.style.display = 'block';\n        } else {\n            \n            console.log('');            \n           \n            desktopContent.style.display = 'block';\n            mobileContent.style.display = 'none';\n        }\n    \u003c\/script\u003e\n\n\n\n\u003c\/body\u003e","brand":"U.S. Solid","offers":[{"title":"NPT","offer_id":46918681624831,"sku":"JFMSV00419","price":55.15,"currency_code":"USD","in_stock":true},{"title":"G","offer_id":46918681657599,"sku":"JFMSV00419-G","price":49.99,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/1__41511.1729567757.1280.1280.jpg?v=1731291624"},{"product_id":"1-2-upvc-motorized-ball-valve-9-36v-ac-dc-plastic-electrical-ball-valve-with-standard-port-2-wire-auto-return-normally-open-html","title":"1\/2\" UPVC Motorized Ball Valve - 9-24V AC\/DC Plastic Electrical Ball Valve with Standard Port, 2 Wire Auto Return, Normally Open","description":"\u003cbody\u003e \n\n\n    \u003cstyle\u003e\n        @media only screen and (max-width: 600px) {\n        }\n    \u003c\/style\u003e\n\n\n    \u003cdiv class=\"desktop-only\"\u003e\n        \n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; line-height: 26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 10px; color: black; font-family: Arial;\"\u003eMotorized ball valves are a vital piece of equipment in numerous applications. This model opens and closes in 6-8 seconds, and remains in its new position while expending almost no energy. This is a key difference between motorized ball valves and many solenoid valves. Most solenoid valves are energized continuously when in a new position, while motorized ball valves expend energy only when changing from open to close, or vice versa.\u003cbr\u003eThe 2 wire auto return model is perfect for situations where the valve needs to be Open in case of power loss. The valve can be energized to open, and left hooked up, with negligible energy used once fully opened. To close, simply shutoff power to the valve. This valve is convenient because it can be operated with a simple on off switch. When on, it will remain open, when turned off (or power is lost for some other reason) the valve automatically closes.\u003c\/p\u003e\n        \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/1.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n             \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n    \u003ctable style=\"border-collapse: collapse;\n                  border: 0px;\n                  width: 100%;\n                  font-family: Arial;\n                  overflow-x: auto;\n                  background-color: #FFFFFF;\"\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"width: 100%;text-align: left;\n                       padding: 0px;\n                       font-size: 16px;\n                       border: 0;\n                       background-color: #FFFFFF;\"\u003e\n                \u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 1\/2\" style=\"width: 100%;height: 100%;\"\u003e\n            \u003c\/td\u003e\n            \u003ctd style=\"width: 100%;text-align: left;\n                       padding: 0px;\n                       font-size: 16px;\n                       border: 0;\n                       background-color: #FFFFFF;\"\u003e\n                \u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 1\/2\" style=\"width: 100%;height: 100%;\"\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/table\u003e\n\u003c\/div\u003e\n          \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e \n \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV00414\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eU.S. Solid\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1\/2\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e2 Wire Auto Return\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eUPVC\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e6 - 8 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e9-24V AC\/DC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e5 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e6 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e0°C to 60°C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e80,000 to 100,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eFull\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\/G\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNormally Open\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e-10°C to 40°C\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eIP65\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/CE\/CE-EMC.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n       \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP65 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYES. The motorized ball valve is made of lead-free Polyvinyl Chloride and is NSF certified.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n    \u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                 \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP65 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP65. The first digit 6 indicates complete dust - tightness. The second digit 5 means protection against water jets from any direction. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/valve%20model.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/JFMSV-User-manual.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n    \u003c\/div\u003e\n    \u003cdiv class=\"mobile-only\"\u003e\n        \n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; line-height:26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 0px; color: black; font-family: Arial;\"\u003eMotorized ball valves are a vital piece of equipment in numerous applications. This model opens and closes in 6-8 seconds, and remains in its new position while expending almost no energy. This is a key difference between motorized ball valves and many solenoid valves. Most solenoid valves are energized continuously when in a new position, while motorized ball valves expend energy only when changing from open to close, or vice versa.\u003cbr\u003eThe 2 wire auto return model is perfect for situations where the valve needs to be Open in case of power loss. The valve can be energized to open, and left hooked up, with negligible energy used once fully opened. To close, simply shutoff power to the valve. This valve is convenient because it can be operated with a simple on off switch. When on, it will remain open, when turned off (or power is lost for some other reason) the valve automatically closes.\u003c\/p\u003e\n            \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/1.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-bottom:10px; margin-top:20px; color: black;\"\u003e\u003cstrong\u003eAPPLICATION\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n    \u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 1\/2\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n    \u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 1\/2\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n\u003c\/div\u003e\n      \u003cp style=\"font-size: 16px; text-align: left; margin-bottom:10px; margin-top:20px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV00414\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eU.S. Solid\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1\/2\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e2 Wire Auto Return\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eUPVC\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e6 - 8 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e9-24V AC\/DC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e5 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e6 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e0°C to 60°C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e80,000 to 100,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eFull\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\/G\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNormally Open\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e-10°C to 40°C\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eIP65\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/CE\/CE-EMC.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n       \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP65 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYES. The motorized ball valve is made of lead-free Polyvinyl Chloride and is NSF certified.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n    \u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                 \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP65 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP65. The first digit 6 indicates complete dust - tightness. The second digit 5 means protection against water jets from any direction. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/valve%20model.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material-APP.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/JFMSV-User-manual.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n    \u003cscript\u003e\n\n        \n        const isMobile = window.matchMedia(\"only screen and (max-width: 600px)\").matches;\n        const desktopContent = document.querySelector('.desktop-only');\n        const mobileContent = document.querySelector('.mobile-only');\n\n        if (isMobile) {\n            \n            console.log('');\n            \n            desktopContent.style.display = 'none';\n            mobileContent.style.display = 'block';\n        } else {\n            \n            console.log('');            \n            \n            desktopContent.style.display = 'block';\n            mobileContent.style.display = 'none';\n        }\n    \u003c\/script\u003e\n\n\n\n\u003c\/body\u003e","brand":"U.S. Solid","offers":[{"title":"NPT","offer_id":46918679920895,"sku":"JFMSV00414","price":36.37,"currency_code":"USD","in_stock":true},{"title":"G","offer_id":46918679953663,"sku":"JFMSV00414-G","price":35.37,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/1__97066.1729565864.1280.1280.jpg?v=1731291626"},{"product_id":"3-4-upvc-motorized-ball-valve-9-36v-ac-dc-plastic-electrical-ball-valve-with-standard-port-2-wire-auto-return-normally-open-html","title":"3\/4\" UPVC Motorized Ball Valve - 9-24V AC\/DC Plastic Electrical Ball Valve with Standard Port, 2 Wire Auto Return, Normally Open","description":"\u003cbody\u003e \n\n\n    \u003cstyle\u003e\n        @media only screen and (max-width: 600px) {\n        }\n    \u003c\/style\u003e\n\n\n    \u003cdiv class=\"desktop-only\"\u003e\n        \n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; line-height: 26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 10px; color: black; font-family: Arial;\"\u003eMotorized ball valves are a vital piece of equipment in numerous applications. This model opens and closes in 6-8 seconds, and remains in its new position while expending almost no energy. This is a key difference between motorized ball valves and many solenoid valves. Most solenoid valves are energized continuously when in a new position, while motorized ball valves expend energy only when changing from open to close, or vice versa.\u003cbr\u003eThe 2 wire auto return model is perfect for situations where the valve needs to be Open in case of power loss. The valve can be energized to open, and left hooked up, with negligible energy used once fully opened. To close, simply shutoff power to the valve. This valve is convenient because it can be operated with a simple on off switch. When on, it will remain open, when turned off (or power is lost for some other reason) the valve automatically closes.\u003c\/p\u003e\n        \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/1.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n             \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n    \u003ctable style=\"border-collapse: collapse;\n                  border: 0px;\n                  width: 100%;\n                  font-family: Arial;\n                  overflow-x: auto;\n                  background-color: #FFFFFF;\"\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"width: 100%;text-align: left;\n                       padding: 0px;\n                       font-size: 16px;\n                       border: 0;\n                       background-color: #FFFFFF;\"\u003e\n                \u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 3\/4\" style=\"width: 100%;height: 100%;\"\u003e\n            \u003c\/td\u003e\n            \u003ctd style=\"width: 100%;text-align: left;\n                       padding: 0px;\n                       font-size: 16px;\n                       border: 0;\n                       background-color: #FFFFFF;\"\u003e\n                \u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 3\/4\" style=\"width: 100%;height: 100%;\"\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/table\u003e\n\u003c\/div\u003e\n          \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e \n \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV00415\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eU.S. Solid\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e3\/4\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e2 Wire Auto Return\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eUPVC\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e6 - 8 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e9-24V AC\/DC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e5 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e6 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e0°C to 60°C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e80,000 to 100,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eStandard\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\/G\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNormally Open\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e-10°C to 40°C\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eIP65\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/CE\/CE-EMC.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n       \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP65 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYES. The motorized ball valve is made of lead-free Polyvinyl Chloride and is NSF certified.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n    \u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                 \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP65 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP65. The first digit 6 indicates complete dust - tightness. The second digit 5 means protection against water jets from any direction. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/valve%20model.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/JFMSV-User-manual.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n    \u003c\/div\u003e\n    \u003cdiv class=\"mobile-only\"\u003e\n      \n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; line-height:26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 0px; color: black; font-family: Arial;\"\u003eMotorized ball valves are a vital piece of equipment in numerous applications. This model opens and closes in 6-8 seconds, and remains in its new position while expending almost no energy. This is a key difference between motorized ball valves and many solenoid valves. Most solenoid valves are energized continuously when in a new position, while motorized ball valves expend energy only when changing from open to close, or vice versa.\u003cbr\u003eThe 2 wire auto return model is perfect for situations where the valve needs to be Open in case of power loss. The valve can be energized to open, and left hooked up, with negligible energy used once fully opened. To close, simply shutoff power to the valve. This valve is convenient because it can be operated with a simple on off switch. When on, it will remain open, when turned off (or power is lost for some other reason) the valve automatically closes.\u003c\/p\u003e\n            \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/1.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-bottom:10px; margin-top:20px; color: black;\"\u003e\u003cstrong\u003eAPPLICATION\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n    \u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 3\/4\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n    \u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 3\/4\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n\u003c\/div\u003e\n      \u003cp style=\"font-size: 16px; text-align: left; margin-bottom:10px; margin-top:20px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV00415\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eU.S. Solid\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e3\/4\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e2 Wire Auto Return\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eUPVC\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e6 - 8 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e9-24V AC\/DC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e5 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e6 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e0°C to 60°C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e80,000 to 100,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eStandard\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\/G\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNormally Open\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e-10°C to 40°C\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eIP65\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/CE\/CE-EMC.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n       \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP65 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYES. The motorized ball valve is made of lead-free Polyvinyl Chloride and is NSF certified.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n    \u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                 \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP65 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP65. The first digit 6 indicates complete dust - tightness. The second digit 5 means protection against water jets from any direction. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/valve%20model.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material-APP.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/JFMSV-User-manual.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n    \u003cscript\u003e\n\n        \n        const isMobile = window.matchMedia(\"only screen and (max-width: 600px)\").matches;\n        const desktopContent = document.querySelector('.desktop-only');\n        const mobileContent = document.querySelector('.mobile-only');\n\n        if (isMobile) {\n            \n            console.log('');\n           \n            desktopContent.style.display = 'none';\n            mobileContent.style.display = 'block';\n        } else {\n          \n            console.log('');            \n            \n            desktopContent.style.display = 'block';\n            mobileContent.style.display = 'none';\n        }\n    \u003c\/script\u003e\n\n\n\n\u003c\/body\u003e","brand":"U.S. Solid","offers":[{"title":"NPT","offer_id":46918676218111,"sku":"JFMSV00415","price":38.37,"currency_code":"USD","in_stock":true},{"title":"G","offer_id":46918676250879,"sku":"JFMSV00415-G","price":36.97,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/2__07057.1729566244.1280.1280.jpg?v=1731291624"},{"product_id":"1-2-upvc-motorized-ball-valve-85-265v-ac-plastic-electrical-ball-valve-with-standard-port-2-wire-auto-return-normally-closed","title":"1\/2\" UPVC Motorized Ball Valve - 85-265V AC Plastic Electrical Ball Valve with Standard Port, 2 Wire Auto Return, Normally Closed","description":"\u003cbody\u003e \n\n\n    \u003cstyle\u003e\n        @media only screen and (max-width: 600px) {\n        }\n    \u003c\/style\u003e\n\n\n    \u003cdiv class=\"desktop-only\"\u003e\n        \n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; line-height: 26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 10px; color: black; font-family: Arial;\"\u003eMotorized ball valves are a vital piece of equipment in numerous applications. This model Closes and closes in 6-8 seconds, and remains in its new position while expending almost no energy. This is a key difference between motorized ball valves and many solenoid valves. Most solenoid valves are energized continuously when in a new position, while motorized ball valves expend energy only when changing from Closed to close, or vice versa.\u003cbr\u003eThe 2 wire auto return model is perfect for situations where the valve needs to be Closed in case of power loss. The valve can be energized to Closed, and left hooked up, with negligible energy used once fully Closed. To close, simply shutoff power to the valve. This valve is convenient because it can be operated with a simple on off switch. When on, it will remain Closed, when turned off (or power is lost for some other reason) the valve automatically closes.\u003c\/p\u003e\n        \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/1.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n             \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n    \u003ctable style=\"border-collapse: collapse;\n                  border: 0px;\n                  width: 100%;\n                  font-family: Arial;\n                  overflow-x: auto;\n                  background-color: #FFFFFF;\"\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"width: 100%;text-align: left;\n                       padding: 0px;\n                       font-size: 16px;\n                       border: 0;\n                       background-color: #FFFFFF;\"\u003e\n                \u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 1\/2\" style=\"width: 100%;height: 100%;\"\u003e\n            \u003c\/td\u003e\n            \u003ctd style=\"width: 100%;text-align: left;\n                       padding: 0px;\n                       font-size: 16px;\n                       border: 0;\n                       background-color: #FFFFFF;\"\u003e\n                \u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 1\/2\" style=\"width: 100%;height: 100%;\"\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/table\u003e\n\u003c\/div\u003e\n          \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e \n \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV00417\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eU.S. Solid\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1\/2\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e2 Wire Auto Return\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eUPVC\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e6 - 8 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eAC 85-265V\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e5 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e6 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e0°C to 60°C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e80,000 to 100,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eFull\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\/G\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNormally Closed\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e-10°C to 40°C\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eIP65\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/CE.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n       \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP65 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYES. The motorized ball valve is made of lead-free Polyvinyl Chloride and is NSF certified.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n    \u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                 \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP65 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP65. The first digit 6 indicates complete dust - tightness. The second digit 5 means protection against water jets from any direction. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/valve%20model.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/JFMSV-User-manual.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n    \u003c\/div\u003e\n    \u003cdiv class=\"mobile-only\"\u003e\n        \n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; line-height:26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 0px; color: black; font-family: Arial;\"\u003eMotorized ball valves are a vital piece of equipment in numerous applications. This model Closes and closes in 6-8 seconds, and remains in its new position while expending almost no energy. This is a key difference between motorized ball valves and many solenoid valves. Most solenoid valves are energized continuously when in a new position, while motorized ball valves expend energy only when changing from Closed to close, or vice versa.\u003cbr\u003eThe 2 wire auto return model is perfect for situations where the valve needs to be Closed in case of power loss. The valve can be energized to Closed, and left hooked up, with negligible energy used once fully Closed. To close, simply shutoff power to the valve. This valve is convenient because it can be operated with a simple on off switch. When on, it will remain Closed, when turned off (or power is lost for some other reason) the valve automatically closes.\u003c\/p\u003e\n            \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/1.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-bottom:10px; margin-top:20px; color: black;\"\u003e\u003cstrong\u003eAPPLICATION\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n    \u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 1\/2\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n    \u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 1\/2\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n\u003c\/div\u003e\n      \u003cp style=\"font-size: 16px; text-align: left; margin-bottom:10px; margin-top:20px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV00417\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eU.S. Solid\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1\/2\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e2 Wire Auto Return\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eUPVC\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e6 - 8 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eAC 85-265V\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e5 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e6 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e0°C to 60°C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e80,000 to 100,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eFull\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\/G\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNormally Closed\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e-10°C to 40°C\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eIP65\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/CE.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n       \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP65 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYES. The motorized ball valve is made of lead-free Polyvinyl Chloride and is NSF certified.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n    \u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                 \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP65 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP65. The first digit 6 indicates complete dust - tightness. The second digit 5 means protection against water jets from any direction. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/valve%20model.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material-APP.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/JFMSV-User-manual.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n    \u003cscript\u003e\n\n       \n        const isMobile = window.matchMedia(\"only screen and (max-width: 600px)\").matches;\n        const desktopContent = document.querySelector('.desktop-only');\n        const mobileContent = document.querySelector('.mobile-only');\n\n        if (isMobile) {\n           \n            console.log('');\n            \n            desktopContent.style.display = 'none';\n            mobileContent.style.display = 'block';\n        } else {\n            \n            console.log('');            \n            \n            desktopContent.style.display = 'block';\n            mobileContent.style.display = 'none';\n        }\n    \u003c\/script\u003e\n\n\n\n\u003c\/body\u003e","brand":"U.S. Solid","offers":[{"title":"NPT","offer_id":46918674579711,"sku":"JFMSV00417","price":44.15,"currency_code":"USD","in_stock":true},{"title":"G","offer_id":46918674612479,"sku":"JFMSV00417-G","price":41.99,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/1__67700.1729567146.1280.1280.jpg?v=1731291624"},{"product_id":"1-upvc-motorized-ball-valve-9-36v-ac-dc-plastic-electrical-ball-valve-with-standard-port-2-wire-auto-return-normally-open-html","title":"1\" UPVC Motorized Ball Valve - 9-24V AC\/DC Plastic Electrical Ball Valve with Standard Port, 2 Wire Auto Return, Normally Open","description":"\u003cbody\u003e \n\n\n    \u003cstyle\u003e\n        @media only screen and (max-width: 600px) {\n        }\n    \u003c\/style\u003e\n\n\n    \u003cdiv class=\"desktop-only\"\u003e\n        \n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; line-height: 26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 10px; color: black; font-family: Arial;\"\u003eMotorized ball valves are a vital piece of equipment in numerous applications. This model opens and closes in 6-8 seconds, and remains in its new position while expending almost no energy. This is a key difference between motorized ball valves and many solenoid valves. Most solenoid valves are energized continuously when in a new position, while motorized ball valves expend energy only when changing from open to close, or vice versa.\u003cbr\u003eThe 2 wire auto return model is perfect for situations where the valve needs to be Open in case of power loss. The valve can be energized to open, and left hooked up, with negligible energy used once fully opened. To close, simply shutoff power to the valve. This valve is convenient because it can be operated with a simple on off switch. When on, it will remain open, when turned off (or power is lost for some other reason) the valve automatically closes.\u003c\/p\u003e\n        \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/1.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n             \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n    \u003ctable style=\"border-collapse: collapse;\n                  border: 0px;\n                  width: 100%;\n                  font-family: Arial;\n                  overflow-x: auto;\n                  background-color: #FFFFFF;\"\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"width: 100%;text-align: left;\n                       padding: 0px;\n                       font-size: 16px;\n                       border: 0;\n                       background-color: #FFFFFF;\"\u003e\n                \u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 1\" style=\"width: 100%;height: 100%;\"\u003e\n            \u003c\/td\u003e\n            \u003ctd style=\"width: 100%;text-align: left;\n                       padding: 0px;\n                       font-size: 16px;\n                       border: 0;\n                       background-color: #FFFFFF;\"\u003e\n                \u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 1\" style=\"width: 100%;height: 100%;\"\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/table\u003e\n\u003c\/div\u003e\n          \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e \n \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV00416\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eU.S. Solid\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e2 Wire Auto Return\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eUPVC\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e6 - 8 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e9-24V AC\/DC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e5 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e6 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e0°C to 60°C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e80,000 to 100,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eStandard\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\/G\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNormally Open\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e-10°C to 40°C\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eIP65\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/CE\/CE-EMC.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n       \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP65 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYES. The motorized ball valve is made of lead-free Polyvinyl Chloride and is NSF certified.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n    \u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                 \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP65 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP65. The first digit 6 indicates complete dust - tightness. The second digit 5 means protection against water jets from any direction. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/valve%20model.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/JFMSV-User-manual.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n    \u003c\/div\u003e\n    \u003cdiv class=\"mobile-only\"\u003e\n        \n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; line-height:26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 0px; color: black; font-family: Arial;\"\u003eMotorized ball valves are a vital piece of equipment in numerous applications. This model opens and closes in 6-8 seconds, and remains in its new position while expending almost no energy. This is a key difference between motorized ball valves and many solenoid valves. Most solenoid valves are energized continuously when in a new position, while motorized ball valves expend energy only when changing from open to close, or vice versa.\u003cbr\u003eThe 2 wire auto return model is perfect for situations where the valve needs to be Open in case of power loss. The valve can be energized to open, and left hooked up, with negligible energy used once fully opened. To close, simply shutoff power to the valve. This valve is convenient because it can be operated with a simple on off switch. When on, it will remain open, when turned off (or power is lost for some other reason) the valve automatically closes.\u003c\/p\u003e\n            \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/1.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-bottom:10px; margin-top:20px; color: black;\"\u003e\u003cstrong\u003eAPPLICATION\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n    \u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 1\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n    \u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 1\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n\u003c\/div\u003e\n      \u003cp style=\"font-size: 16px; text-align: left; margin-bottom:10px; margin-top:20px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV00416\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eU.S. Solid\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e2 Wire Auto Return\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eUPVC\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e6 - 8 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e9-24V AC\/DC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e5 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e6 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e0°C to 60°C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e80,000 to 100,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eStandard\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\/G\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNormally Open\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e-10°C to 40°C\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eIP65\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/CE\/CE-EMC.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n       \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP65 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYES. The motorized ball valve is made of lead-free Polyvinyl Chloride and is NSF certified.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n    \u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                 \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP65 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP65. The first digit 6 indicates complete dust - tightness. The second digit 5 means protection against water jets from any direction. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/valve%20model.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material-APP.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/JFMSV-User-manual.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n    \u003cscript\u003e\n\n        \n        const isMobile = window.matchMedia(\"only screen and (max-width: 600px)\").matches;\n        const desktopContent = document.querySelector('.desktop-only');\n        const mobileContent = document.querySelector('.mobile-only');\n\n        if (isMobile) {\n            \n            console.log('');\n        \n            desktopContent.style.display = 'none';\n            mobileContent.style.display = 'block';\n        } else {\n            \n            console.log('');            \n            \n            desktopContent.style.display = 'block';\n            mobileContent.style.display = 'none';\n        }\n    \u003c\/script\u003e\n\n\n\n\u003c\/body\u003e","brand":"U.S. Solid","offers":[{"title":"NPT","offer_id":46918672843007,"sku":"JFMSV00416","price":45.37,"currency_code":"USD","in_stock":true},{"title":"G","offer_id":46918672875775,"sku":"JFMSV00416-G","price":42.97,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/3-2__11258.1729566925.1280.1280.jpg?v=1731291626"},{"product_id":"1-upvc-motorized-ball-valve-9-36v-ac-dc-plastic-electrical-ball-valve-with-standard-port-2-wire-auto-return-normally-closed-html","title":"1\" UPVC Motorized Ball Valve - 9-24V AC\/DC Plastic Electrical Ball Valve with Standard Port, 2 Wire Auto Return, Normally Closed","description":"\u003cbody\u003e \n\n\n    \u003cstyle\u003e\n        @media only screen and (max-width: 600px) {\n        }\n    \u003c\/style\u003e\n\n\n    \u003cdiv class=\"desktop-only\"\u003e\n        \n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; line-height: 26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 10px; color: black; font-family: Arial;\"\u003eMotorized ball valves are a vital piece of equipment in numerous applications. This model opens and closes in 6-8 seconds, and remains in its new position while expending almost no energy. This is a key difference between motorized ball valves and many solenoid valves. Most solenoid valves are energized continuously when in a new position, while motorized ball valves expend energy only when changing from open to close, or vice versa.\u003cbr\u003eThe 2 wire auto return model is perfect for situations where the valve needs to be closed in case of power loss. The valve can be energized to open, and left hooked up, with negligible energy used once fully opened. To close, simply shutoff power to the valve. This valve is convenient because it can be operated with a simple on off switch. When on, it will remain open, when turned off (or power is lost for some other reason) the valve automatically closes.\u003c\/p\u003e\n        \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/1.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n             \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n    \u003ctable style=\"border-collapse: collapse;\n                  border: 0px;\n                  width: 100%;\n                  font-family: Arial;\n                  overflow-x: auto;\n                  background-color: #FFFFFF;\"\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"width: 100%;text-align: left;\n                       padding: 0px;\n                       font-size: 16px;\n                       border: 0;\n                       background-color: #FFFFFF;\"\u003e\n                \u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 1\" style=\"width: 100%;height: 100%;\"\u003e\n            \u003c\/td\u003e\n            \u003ctd style=\"width: 100%;text-align: left;\n                       padding: 0px;\n                       font-size: 16px;\n                       border: 0;\n                       background-color: #FFFFFF;\"\u003e\n                \u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 1\" style=\"width: 100%;height: 100%;\"\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/table\u003e\n\u003c\/div\u003e\n          \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e \n \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV00413\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eU.S. Solid\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e2 Wire Auto Return\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eUPVC\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e6 - 8 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e9-24V AC\/DC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e5 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e6 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e0°C to 60°C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e80,000 to 100,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eStandard\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\/G\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNormally Closed\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e-10°C to 40°C\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eIP65\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/CE\/CE-EMC.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n       \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP65 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYES. The motorized ball valve is made of lead-free Polyvinyl Chloride and is NSF certified.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n    \u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                 \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP65 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP65. The first digit 6 indicates complete dust - tightness. The second digit 5 means protection against water jets from any direction. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/valve%20model.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/JFMSV-User-manual.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n    \u003c\/div\u003e\n    \u003cdiv class=\"mobile-only\"\u003e\n     \n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; line-height:26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 0px; color: black; font-family: Arial;\"\u003eMotorized ball valves are a vital piece of equipment in numerous applications. This model opens and closes in 6-8 seconds, and remains in its new position while expending almost no energy. This is a key difference between motorized ball valves and many solenoid valves. Most solenoid valves are energized continuously when in a new position, while motorized ball valves expend energy only when changing from open to close, or vice versa.\u003cbr\u003eThe 2 wire auto return model is perfect for situations where the valve needs to be closed in case of power loss. The valve can be energized to open, and left hooked up, with negligible energy used once fully opened. To close, simply shutoff power to the valve. This valve is convenient because it can be operated with a simple on off switch. When on, it will remain open, when turned off (or power is lost for some other reason) the valve automatically closes.\u003c\/p\u003e\n            \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/1.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-bottom:10px; margin-top:20px; color: black;\"\u003e\u003cstrong\u003eAPPLICATION\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n    \u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 1\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n    \u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 1\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n\u003c\/div\u003e\n      \u003cp style=\"font-size: 16px; text-align: left; margin-bottom:10px; margin-top:20px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV00413\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eU.S. Solid\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e2 Wire Auto Return\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eUPVC\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e6 - 8 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e9-24V AC\/DC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e5 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e6 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e0°C to 60°C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e80,000 to 100,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eStandard\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\/G\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNormally Closed\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e-10°C to 40°C\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eIP65\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/CE\/CE-EMC.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n       \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP65 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYES. The motorized ball valve is made of lead-free Polyvinyl Chloride and is NSF certified.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n    \u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                 \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP65 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP65. The first digit 6 indicates complete dust - tightness. The second digit 5 means protection against water jets from any direction. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/valve%20model.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material-APP.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/JFMSV-User-manual.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n    \u003cscript\u003e\n\n        \n        const isMobile = window.matchMedia(\"only screen and (max-width: 600px)\").matches;\n        const desktopContent = document.querySelector('.desktop-only');\n        const mobileContent = document.querySelector('.mobile-only');\n\n        if (isMobile) {\n            \n            console.log('');\n         \n            desktopContent.style.display = 'none';\n            mobileContent.style.display = 'block';\n        } else {\n            \n            console.log('');            \n           \n            desktopContent.style.display = 'block';\n            mobileContent.style.display = 'none';\n        }\n    \u003c\/script\u003e\n\n\n\n\u003c\/body\u003e","brand":"U.S. Solid","offers":[{"title":"NPT","offer_id":46918671204607,"sku":"JFMSV00413","price":42.07,"currency_code":"USD","in_stock":true},{"title":"G","offer_id":46918671237375,"sku":"JFMSV00413-G","price":41.97,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/2__59562.1729565368.1280.1280.jpg?v=1731291626"},{"product_id":"3-4-upvc-motorized-ball-valve-9-36v-ac-dc-plastic-electrical-ball-valve-with-standard-port-2-wire-auto-return-normally-closed-html","title":"3\/4\" UPVC Motorized Ball Valve - 9-24V AC\/DC Plastic Electrical Ball Valve with Standard Port, 2 Wire Auto Return, Normally Closed","description":"\u003cbody\u003e \n\n\n    \u003cstyle\u003e\n        @media only screen and (max-width: 600px) {\n        }\n    \u003c\/style\u003e\n\n\n    \u003cdiv class=\"desktop-only\"\u003e\n        \n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; line-height: 26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 10px; color: black; font-family: Arial;\"\u003eMotorized ball valves are a vital piece of equipment in numerous applications. This model opens and closes in 6-8 seconds, and remains in its new position while expending almost no energy. This is a key difference between motorized ball valves and many solenoid valves. Most solenoid valves are energized continuously when in a new position, while motorized ball valves expend energy only when changing from open to close, or vice versa.\u003cbr\u003eThe 2 wire auto return model is perfect for situations where the valve needs to be closed in case of power loss. The valve can be energized to open, and left hooked up, with negligible energy used once fully opened. To close, simply shutoff power to the valve. This valve is convenient because it can be operated with a simple on off switch. When on, it will remain open, when turned off (or power is lost for some other reason) the valve automatically closes.\u003c\/p\u003e\n        \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/1.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n             \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n    \u003ctable style=\"border-collapse: collapse;\n                  border: 0px;\n                  width: 100%;\n                  font-family: Arial;\n                  overflow-x: auto;\n                  background-color: #FFFFFF;\"\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"width: 100%;text-align: left;\n                       padding: 0px;\n                       font-size: 16px;\n                       border: 0;\n                       background-color: #FFFFFF;\"\u003e\n                \u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 3\/4\" style=\"width: 100%;height: 100%;\"\u003e\n            \u003c\/td\u003e\n            \u003ctd style=\"width: 100%;text-align: left;\n                       padding: 0px;\n                       font-size: 16px;\n                       border: 0;\n                       background-color: #FFFFFF;\"\u003e\n                \u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 3\/4\" style=\"width: 100%;height: 100%;\"\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/table\u003e\n\u003c\/div\u003e\n          \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e \n \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV00412\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eU.S. Solid\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e3\/4\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e2 Wire Auto Return\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eUPVC\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e6 - 8 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e9-24V AC\/DC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e5 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e6 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e0°C to 60°C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e80,000 to 100,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eStandard\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\/G\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNormally Closed\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e-10°C to 40°C\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eIP65\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/CE\/CE-EMC.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP65 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYES. The motorized ball valve is made of lead-free Polyvinyl Chloride and is NSF certified.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n    \u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP65 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP65. The first digit 6 indicates complete dust - tightness. The second digit 5 means protection against water jets from any direction. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/valve%20model.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/JFMSV-User-manual.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n    \u003c\/div\u003e\n    \u003cdiv class=\"mobile-only\"\u003e\n        \n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; line-height:26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 0px; color: black; font-family: Arial;\"\u003eMotorized ball valves are a vital piece of equipment in numerous applications. This model opens and closes in 6-8 seconds, and remains in its new position while expending almost no energy. This is a key difference between motorized ball valves and many solenoid valves. Most solenoid valves are energized continuously when in a new position, while motorized ball valves expend energy only when changing from open to close, or vice versa.\u003cbr\u003eThe 2 wire auto return model is perfect for situations where the valve needs to be closed in case of power loss. The valve can be energized to open, and left hooked up, with negligible energy used once fully opened. To close, simply shutoff power to the valve. This valve is convenient because it can be operated with a simple on off switch. When on, it will remain open, when turned off (or power is lost for some other reason) the valve automatically closes.\u003c\/p\u003e\n            \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/1.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-bottom:10px; margin-top:20px; color: black;\"\u003e\u003cstrong\u003eAPPLICATION\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n    \u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 3\/4\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n    \u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 3\/4\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n\u003c\/div\u003e\n      \u003cp style=\"font-size: 16px; text-align: left; margin-bottom:10px; margin-top:20px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV00412\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eU.S. Solid\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e3\/4\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e2 Wire Auto Return\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eUPVC\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e6 - 8 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e9-24V AC\/DC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e5 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e6 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e0°C to 60°C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e80,000 to 100,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eStandard\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\/G\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNormally Closed\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e-10°C to 40°C\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eIP65\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/CE\/CE-EMC.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP65 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYES. The motorized ball valve is made of lead-free Polyvinyl Chloride and is NSF certified.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n    \u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP65 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP65. The first digit 6 indicates complete dust - tightness. The second digit 5 means protection against water jets from any direction. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/valve%20model.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material-APP.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/JFMSV-User-manual.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n    \u003cscript\u003e\n\n        \n        const isMobile = window.matchMedia(\"only screen and (max-width: 600px)\").matches;\n        const desktopContent = document.querySelector('.desktop-only');\n        const mobileContent = document.querySelector('.mobile-only');\n\n        if (isMobile) {\n       \n            console.log('');\n            \n            desktopContent.style.display = 'none';\n            mobileContent.style.display = 'block';\n        } else {\n           \n            console.log('');            \n          \n            desktopContent.style.display = 'block';\n            mobileContent.style.display = 'none';\n        }\n    \u003c\/script\u003e\n\n\n\n\u003c\/body\u003e","brand":"U.S. Solid","offers":[{"title":"NPT","offer_id":46918668124415,"sku":"JFMSV00412","price":36.07,"currency_code":"USD","in_stock":true},{"title":"G","offer_id":46918668157183,"sku":"JFMSV00412-G","price":35.97,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/1__00390.1729564980.1280.1280.jpg?v=1731291627"},{"product_id":"3-4-upvc-motorized-ball-valve-85-265v-ac-plastic-electrical-ball-valve-with-standard-port-2-wire-auto-return-normally-closed","title":"3\/4\" UPVC Motorized Ball Valve -85-265V AC Plastic Electrical Ball Valve with Standard Port, 2 Wire Auto Return, Normally Closed","description":"\u003cbody\u003e \n\n\n    \u003cstyle\u003e\n        @media only screen and (max-width: 600px) {\n        }\n    \u003c\/style\u003e\n\n\n    \u003cdiv class=\"desktop-only\"\u003e\n        \n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; line-height: 26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 10px; color: black; font-family: Arial;\"\u003eMotorized ball valves are a vital piece of equipment in numerous applications. This model Closes and closes in 6-8 seconds, and remains in its new position while expending almost no energy. This is a key difference between motorized ball valves and many solenoid valves. Most solenoid valves are energized continuously when in a new position, while motorized ball valves expend energy only when changing from Closed to close, or vice versa.\u003cbr\u003eThe 2 wire auto return model is perfect for situations where the valve needs to be Closed in case of power loss. The valve can be energized to Closed, and left hooked up, with negligible energy used once fully Closed. To close, simply shutoff power to the valve. This valve is convenient because it can be operated with a simple on off switch. When on, it will remain Closed, when turned off (or power is lost for some other reason) the valve automatically closes.\u003c\/p\u003e\n        \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/1.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n             \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n    \u003ctable style=\"border-collapse: collapse;\n                  border: 0px;\n                  width: 100%;\n                  font-family: Arial;\n                  overflow-x: auto;\n                  background-color: #FFFFFF;\"\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"width: 100%;text-align: left;\n                       padding: 0px;\n                       font-size: 16px;\n                       border: 0;\n                       background-color: #FFFFFF;\"\u003e\n                \u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 3\/4\" style=\"width: 100%;height: 100%;\"\u003e\n            \u003c\/td\u003e\n            \u003ctd style=\"width: 100%;text-align: left;\n                       padding: 0px;\n                       font-size: 16px;\n                       border: 0;\n                       background-color: #FFFFFF;\"\u003e\n                \u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 3\/4\" style=\"width: 100%;height: 100%;\"\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/table\u003e\n\u003c\/div\u003e\n          \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e \n \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV00418\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eU.S. Solid\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e3\/4\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e2 Wire Auto Return\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eUPVC\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e6 - 8 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eAC 85-265V\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e5 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e6 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e0°C to 60°C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e80,000 to 100,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eStandard\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\/G\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNormally Closed\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e-10°C to 40°C\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eIP65\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/CE.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n       \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP65 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYES. The motorized ball valve is made of lead-free Polyvinyl Chloride and is NSF certified.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n    \u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                 \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP65 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP65. The first digit 6 indicates complete dust - tightness. The second digit 5 means protection against water jets from any direction. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e\n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/valve%20model.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/JFMSV-User-manual.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n    \u003c\/div\u003e\n    \u003cdiv class=\"mobile-only\"\u003e\n        \n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; line-height:26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 0px; color: black; font-family: Arial;\"\u003eMotorized ball valves are a vital piece of equipment in numerous applications. This model Closes and closes in 6-8 seconds, and remains in its new position while expending almost no energy. This is a key difference between motorized ball valves and many solenoid valves. Most solenoid valves are energized continuously when in a new position, while motorized ball valves expend energy only when changing from Closed to close, or vice versa.\u003cbr\u003eThe 2 wire auto return model is perfect for situations where the valve needs to be Closed in case of power loss. The valve can be energized to Closed, and left hooked up, with negligible energy used once fully Closed. To close, simply shutoff power to the valve. This valve is convenient because it can be operated with a simple on off switch. When on, it will remain Closed, when turned off (or power is lost for some other reason) the valve automatically closes.\u003c\/p\u003e\n            \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/1.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-bottom:10px; margin-top:20px; color: black;\"\u003e\u003cstrong\u003eAPPLICATION\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n    \u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 3\/4\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n    \u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 3\/4\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n\u003c\/div\u003e\n      \u003cp style=\"font-size: 16px; text-align: left; margin-bottom:10px; margin-top:20px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV00418\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eU.S. Solid\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e3\/4\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e2 Wire Auto Return\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eUPVC\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e6 - 8 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eAC 85-265V\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e5 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e6 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e0°C to 60°C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e80,000 to 100,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eStandard\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\/G\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNormally Closed\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e-10°C to 40°C\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eIP65\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/CE.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n       \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP65 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYES. The motorized ball valve is made of lead-free Polyvinyl Chloride and is NSF certified.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n    \u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                 \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP65 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP65. The first digit 6 indicates complete dust - tightness. The second digit 5 means protection against water jets from any direction. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/valve%20model.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material-APP.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/JFMSV-User-manual.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n    \u003cscript\u003e\n\n        \n        const isMobile = window.matchMedia(\"only screen and (max-width: 600px)\").matches;\n        const desktopContent = document.querySelector('.desktop-only');\n        const mobileContent = document.querySelector('.mobile-only');\n\n        if (isMobile) {\n           \n            console.log('');\n            \n            desktopContent.style.display = 'none';\n            mobileContent.style.display = 'block';\n        } else {\n           \n            console.log('');            \n           \n            desktopContent.style.display = 'block';\n            mobileContent.style.display = 'none';\n        }\n    \u003c\/script\u003e\n\n\n\n\u003c\/body\u003e","brand":"U.S. Solid","offers":[{"title":"NPT","offer_id":46918665797887,"sku":"JFMSV00418","price":45.15,"currency_code":"USD","in_stock":true},{"title":"G","offer_id":46918665830655,"sku":"JFMSV00418-G","price":44.99,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/1__90683.1729567530.1280.1280.jpg?v=1731291628"},{"product_id":"1-2-pvc-motorized-ball-valve-110-220v-ac-plastic-electric-ball-valve-auto-return-normally-closed","title":"1\/2\" PVC Motorized Ball Valve - 110\/220V AC Plastic Electric Ball Valve, Auto Return, Normally Closed","description":"\u003cstyle\u003e\n        @media only screen and (max-width: 600px) {\n        }\n    \u003c\/style\u003e\n\u003cdiv class=\"desktop-only\"\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top: 0px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; line-height: 26px; color: black; font-family: Arial; margin: 10px 0px 0px 0px;\"\u003eMotorized ball valves present an energy-efficient substitute for solenoid valves, particularly when it comes to prolonged positioning. They primarily consume power during the processes of opening and closing, and the energy consumption is negligible once they are fully opened. This characteristic enables a permanent connection, eliminating the risks of overheating or burnout.\u003c\/p\u003e\n\u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/1.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n\u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #ffffff;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 0px; font-size: 16px; border: 0; background-color: #ffffff;\"\u003e\n\u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 1\" style=\"width: 100%; height: 100%;\"\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 0px; font-size: 16px; border: 0; background-color: #ffffff;\"\u003e\n\u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 2\" style=\"width: 100%; height: 100%;\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n\u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #ffffff;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003eUSS-MSV20013\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003eU.S. Solid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003e1\/2\"\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003eUS Plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003ePPE\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003ePTFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003e6 - 8 Seconds\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003eAC 110V\/220V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003e5 W\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003e3 N m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003e1.0 Mpa\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003e0℃-90 ℃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003e70,000 Cycles\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003eStandard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003eNPT\/G\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003eNormally Closed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003e-10℃- 40 ℃\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #ffffff;\"\u003eIP67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/CE.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial; line-height: 26px;\"\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eThe motor's housing is rated at IP67 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eYES. The motorized ball valve is made of PPE.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial; line-height: 26px;\"\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top: 20px; margin-bottom: 10px; line-height: 26px; color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP67 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eThe valves have an ingress - protection rating of IP67. The first digit 6 indicates complete dust - tightness. The second digit 7 means protection from immersion(up to 1M) for a limited time. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/IP67-SS304.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/Manual%20for%20Tonhe.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mobile-only\"\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top: 0px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; line-height: 26px; color: black; font-family: Arial; margin: 0px;\"\u003eMotorized ball valves present an energy-efficient substitute for solenoid valves, particularly when it comes to prolonged positioning. They primarily consume power during the processes of opening and closing, and the energy consumption is negligible once they are fully opened. This characteristic enables a permanent connection, eliminating the risks of overheating or burnout.\u003c\/p\u003e\n\u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/1.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-bottom: 10px; margin-top: 20px; color: black;\"\u003e\u003cstrong\u003eAPPLICATION\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n\u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 1\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n\u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 2\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 16px; text-align: left; margin-bottom: 10px; margin-top: 20px; color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n\u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #ffffff;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003eUSS-MSV20013\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003eU.S. Solid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003e1\/2\"\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003eUS Plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003ePPE\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003ePTFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003e6 - 8 Seconds\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003eAC 110V\/220V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003e5 W\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003e3 N m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003e1.0 Mpa\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003e0℃-90 ℃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003e70,000 Cycles\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003eStandard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003eNPT\/G\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003eNormally Closed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003e-10℃- 40 ℃\u003c\/td\u003e\n\u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n\u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #ffffff;\"\u003eIP67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/CE.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial; line-height: 26px;\"\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eThe motor's housing is rated at IP67 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eYES. The motorized ball valve is made of PPE.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial; line-height: 26px;\"\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top: 20px; margin-bottom: 10px; line-height: 26px; color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP67 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eThe valves have an ingress - protection rating of IP67. The first digit 6 indicates complete dust - tightness. The second digit 7 means protection from immersion(up to 1M) for a limited time. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/IP67-SS304.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 22px; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material-APP.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cp style=\"font-size: 16px; margin-top: 5px; margin-bottom: 5px; line-height: 26px; color: black;\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/Manual%20for%20Tonhe.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"U.S. Solid","offers":[{"title":"110V AC \/ NPT","offer_id":47055981314303,"sku":"JFMSV20013","price":74.0,"currency_code":"USD","in_stock":true},{"title":"220V AC \/ G","offer_id":47055981347071,"sku":"JFMSV20013-G","price":74.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/3_7ee1b2b3-1249-4f5a-9924-2f31864a9fd8.png?v=1750400239"},{"product_id":"3-4-pvc-motorized-ball-valve-110-220v-ac-plastic-electric-ball-valve-auto-return-normally-closed","title":"3\/4\" PVC Motorized Ball Valve - 110\/220V AC Plastic Electric Ball Valve, Auto Return, Normally Closed","description":"\u003cbody\u003e \n\n\n    \u003cstyle\u003e\n        @media only screen and (max-width: 600px) {\n        }\n    \u003c\/style\u003e\n\n\n    \u003cdiv class=\"desktop-only\"\u003e\n     \n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; line-height: 26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 10px; color: black; font-family: Arial;\"\u003eMotorized ball valves present an energy-efficient substitute for solenoid valves, particularly when it comes to prolonged positioning. They primarily consume power during the processes of opening and closing, and the energy consumption is negligible once they are fully opened. This characteristic enables a permanent connection, eliminating the risks of overheating or burnout.\u003c\/p\u003e\n        \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/1.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n             \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n    \u003ctable style=\"border-collapse: collapse;\n                  border: 0px;\n                  width: 100%;\n                  font-family: Arial;\n                  overflow-x: auto;\n                  background-color: #FFFFFF;\"\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"width: 100%;text-align: left;\n                       padding: 0px;\n                       font-size: 16px;\n                       border: 0;\n                       background-color: #FFFFFF;\"\u003e\n                \u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 1\" style=\"width: 100%;height: 100%;\"\u003e\n            \u003c\/td\u003e\n            \u003ctd style=\"width: 100%;text-align: left;\n                       padding: 0px;\n                       font-size: 16px;\n                       border: 0;\n                       background-color: #FFFFFF;\"\u003e\n                \u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 2\" style=\"width: 100%;height: 100%;\"\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/table\u003e\n\u003c\/div\u003e\n          \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e \n \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV20014\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eU.S. Solid\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e3\/4\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eUS Plug\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003ePPE\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e6 - 8 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eAC 110V\/220V\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e5 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e3 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e0℃-90 ℃\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e70,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eStandard\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\/G\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNormally Closed\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e-10℃- 40 ℃\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eIP67\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/CE.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP67 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYES. The motorized ball valve is made of PPE.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n    \u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP67 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP67. The first digit 6 indicates complete dust - tightness. The second digit 7 means protection from immersion(up to 1M) for a limited time. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/IP67-SS304.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/Manual%20for%20Tonhe.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n    \u003c\/div\u003e\n    \u003cdiv class=\"mobile-only\"\u003e\n        \n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; line-height:26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 0px; color: black; font-family: Arial;\"\u003eMotorized ball valves present an energy-efficient substitute for solenoid valves, particularly when it comes to prolonged positioning. They primarily consume power during the processes of opening and closing, and the energy consumption is negligible once they are fully opened. This characteristic enables a permanent connection, eliminating the risks of overheating or burnout.\u003c\/p\u003e\n            \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/1.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-bottom:10px; margin-top:20px; color: black;\"\u003e\u003cstrong\u003eAPPLICATION\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n    \u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 1\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n    \u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 2\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n\u003c\/div\u003e\n      \u003cp style=\"font-size: 16px; text-align: left; margin-bottom:10px; margin-top:20px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n       \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV20014\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eU.S. Solid\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e3\/4\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eUS Plug\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003ePPE\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e6 - 8 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eAC 110V\/220V\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e5 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e3 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e0℃-90 ℃\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e70,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eStandard\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\/G\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNormally Closed\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e-10℃- 40 ℃\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eIP67\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/CE.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n       \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP67 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYES. The motorized ball valve is made of PPE.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n    \u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                 \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP67 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP67. The first digit 6 indicates complete dust - tightness. The second digit 7 means protection from immersion(up to 1M) for a limited time. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/IP67-SS304.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material-APP.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/Manual%20for%20Tonhe.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n    \u003cscript\u003e\n\n       \n        const isMobile = window.matchMedia(\"only screen and (max-width: 600px)\").matches;\n        const desktopContent = document.querySelector('.desktop-only');\n        const mobileContent = document.querySelector('.mobile-only');\n\n        if (isMobile) {\n           \n            console.log('');\n            \n            desktopContent.style.display = 'none';\n            mobileContent.style.display = 'block';\n        } else {\n       \n            console.log('');            \n           \n            desktopContent.style.display = 'block';\n            mobileContent.style.display = 'none';\n        }\n    \u003c\/script\u003e\n\n\n\n\u003c\/body\u003e","brand":"U.S. Solid","offers":[{"title":"110V AC \/ NPT","offer_id":47043370418431,"sku":"JFMSV20014","price":82.0,"currency_code":"USD","in_stock":true},{"title":"220V AC \/ G","offer_id":47043370451199,"sku":"JFMSV20014-G","price":84.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/3_d6990b8c-c28a-46a8-be53-45b2ca3cc2b0.png?v=1751534533"},{"product_id":"1-pvc-motorized-ball-valve-110-220v-ac-plastic-electric-ball-valve-auto-return-normally-closed","title":"1\" PVC Motorized Ball Valve - 110\/220V AC Plastic Electric Ball Valve, Auto Return, Normally Closed","description":"\u003cbody\u003e \n\n\n    \u003cstyle\u003e\n        @media only screen and (max-width: 600px) {\n        }\n    \u003c\/style\u003e\n\n\n    \u003cdiv class=\"desktop-only\"\u003e\n     \n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; line-height: 26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 10px; color: black; font-family: Arial;\"\u003eMotorized ball valves present an energy-efficient substitute for solenoid valves, particularly when it comes to prolonged positioning. They primarily consume power during the processes of opening and closing, and the energy consumption is negligible once they are fully opened. This characteristic enables a permanent connection, eliminating the risks of overheating or burnout.\u003c\/p\u003e\n        \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/1.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n             \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n    \u003ctable style=\"border-collapse: collapse;\n                  border: 0px;\n                  width: 100%;\n                  font-family: Arial;\n                  overflow-x: auto;\n                  background-color: #FFFFFF;\"\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"width: 100%;text-align: left;\n                       padding: 0px;\n                       font-size: 16px;\n                       border: 0;\n                       background-color: #FFFFFF;\"\u003e\n                \u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 1\" style=\"width: 100%;height: 100%;\"\u003e\n            \u003c\/td\u003e\n            \u003ctd style=\"width: 100%;text-align: left;\n                       padding: 0px;\n                       font-size: 16px;\n                       border: 0;\n                       background-color: #FFFFFF;\"\u003e\n                \u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 2\" style=\"width: 100%;height: 100%;\"\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/table\u003e\n\u003c\/div\u003e\n          \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e \n \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV20015\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eU.S. Solid\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eUS Plug\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003ePPE\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e6 - 8 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eAC 110V\/220V\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e5 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e3 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e0℃-90 ℃\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e70,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eStandard\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\/G\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNormally Closed\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e-10℃- 40 ℃\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eIP67\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/CE.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP67 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYES. The motorized ball valve is made of PPE.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n    \u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP67 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP67. The first digit 6 indicates complete dust - tightness. The second digit 7 means protection from immersion(up to 1M) for a limited time. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/IP67-SS304.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/Manual%20for%20Tonhe.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n    \u003c\/div\u003e\n    \u003cdiv class=\"mobile-only\"\u003e\n        \n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; line-height:26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 0px; color: black; font-family: Arial;\"\u003eMotorized ball valves present an energy-efficient substitute for solenoid valves, particularly when it comes to prolonged positioning. They primarily consume power during the processes of opening and closing, and the energy consumption is negligible once they are fully opened. This characteristic enables a permanent connection, eliminating the risks of overheating or burnout.\u003c\/p\u003e\n            \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/1.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-bottom:10px; margin-top:20px; color: black;\"\u003e\u003cstrong\u003eAPPLICATION\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n    \u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 1\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n    \u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 2\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n\u003c\/div\u003e\n      \u003cp style=\"font-size: 16px; text-align: left; margin-bottom:10px; margin-top:20px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n       \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV20015\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eU.S. Solid\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eUS Plug\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003ePPE\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e6 - 8 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eAC 110V\/220V\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e5 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e3 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e0℃-90 ℃\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e70,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eStandard\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\/G\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNormally Closed\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e-10℃- 40 ℃\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eIP67\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/CE.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n       \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP67 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYES. The motorized ball valve is made of PPE.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n    \u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                 \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP67 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP67. The first digit 6 indicates complete dust - tightness. The second digit 7 means protection from immersion(up to 1M) for a limited time. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/IP67-SS304.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material-APP.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/Manual%20for%20Tonhe.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n    \u003cscript\u003e\n\n       \n        const isMobile = window.matchMedia(\"only screen and (max-width: 600px)\").matches;\n        const desktopContent = document.querySelector('.desktop-only');\n        const mobileContent = document.querySelector('.mobile-only');\n\n        if (isMobile) {\n           \n            console.log('');\n            \n            desktopContent.style.display = 'none';\n            mobileContent.style.display = 'block';\n        } else {\n       \n            console.log('');            \n           \n            desktopContent.style.display = 'block';\n            mobileContent.style.display = 'none';\n        }\n    \u003c\/script\u003e\n\n\n\n\u003c\/body\u003e","brand":"U.S. Solid","offers":[{"title":"110V AC \/ NPT","offer_id":47055982133503,"sku":"JFMSV20015","price":99.0,"currency_code":"USD","in_stock":true},{"title":"220V AC \/ G","offer_id":47055982166271,"sku":"JFMSV20015-G","price":94.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/3_33aff181-7b53-4c7d-a2f5-9e72d870b606.png?v=1750400254"},{"product_id":"1-2-pvc-motorized-ball-valve-110v-ac-electric-ball-valve-auto-return-normally-closed","title":"1\/2\" PVC Motorized Ball Valve - 110\/220V AC Plastic Electric Ball Valve, Auto Return, Normally Closed","description":"\u003cbody\u003e \n\n\n    \u003cstyle\u003e\n        @media only screen and (max-width: 600px) {\n        }\n    \u003c\/style\u003e\n\n\n    \u003cdiv class=\"desktop-only\"\u003e\n     \n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; line-height: 26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 10px; color: black; font-family: Arial;\"\u003eMotorized ball valves present an energy-efficient substitute for solenoid valves, particularly when it comes to prolonged positioning. They primarily consume power during the processes of opening and closing, and the energy consumption is negligible once they are fully opened. This characteristic enables a permanent connection, eliminating the risks of overheating or burnout.\u003c\/p\u003e\n        \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/1.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n             \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n    \u003ctable style=\"border-collapse: collapse;\n                  border: 0px;\n                  width: 100%;\n                  font-family: Arial;\n                  overflow-x: auto;\n                  background-color: #FFFFFF;\"\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"width: 100%;text-align: left;\n                       padding: 0px;\n                       font-size: 16px;\n                       border: 0;\n                       background-color: #FFFFFF;\"\u003e\n                \u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 1\" style=\"width: 100%;height: 100%;\"\u003e\n            \u003c\/td\u003e\n            \u003ctd style=\"width: 100%;text-align: left;\n                       padding: 0px;\n                       font-size: 16px;\n                       border: 0;\n                       background-color: #FFFFFF;\"\u003e\n                \u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 2\" style=\"width: 100%;height: 100%;\"\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/table\u003e\n\u003c\/div\u003e\n          \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e \n \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV20016\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eU.S. Solid\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1\/2\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eUS Plug\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eUPVC\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e6 - 8 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eAC 110V\/220V\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e5 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e3 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e0℃-90 ℃\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e70,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eStandard\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\/G\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNormally Closed\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e-10℃- 40 ℃\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eIP67\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/CE.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP67 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYES. The motorized ball valve is made of UPVC.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n    \u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP67 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP67. The first digit 6 indicates complete dust - tightness. The second digit 7 means protection from immersion(up to 1M) for a limited time. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/IP67-SS304.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/Manual%20for%20Tonhe.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n    \u003c\/div\u003e\n    \u003cdiv class=\"mobile-only\"\u003e\n        \n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; line-height:26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 0px; color: black; font-family: Arial;\"\u003eMotorized ball valves present an energy-efficient substitute for solenoid valves, particularly when it comes to prolonged positioning. They primarily consume power during the processes of opening and closing, and the energy consumption is negligible once they are fully opened. This characteristic enables a permanent connection, eliminating the risks of overheating or burnout.\u003c\/p\u003e\n            \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/1.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-bottom:10px; margin-top:20px; color: black;\"\u003e\u003cstrong\u003eAPPLICATION\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n    \u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 1\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n    \u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 2\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n\u003c\/div\u003e\n      \u003cp style=\"font-size: 16px; text-align: left; margin-bottom:10px; margin-top:20px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n       \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV20016\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eU.S. Solid\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1\/2\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eUS Plug\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eUPVC\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e6 - 8 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eAC 110V\/220V\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e5 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e3 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e0℃-90 ℃\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e70,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eStandard\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\/G\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNormally Closed\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e-10℃- 40 ℃\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eIP67\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/CE.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n       \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP67 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYES. The motorized ball valve is made of UPVC.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n    \u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                 \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP67 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP67. The first digit 6 indicates complete dust - tightness. The second digit 7 means protection from immersion(up to 1M) for a limited time. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/IP67-SS304.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material-APP.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/Manual%20for%20Tonhe.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n    \u003cscript\u003e\n\n       \n        const isMobile = window.matchMedia(\"only screen and (max-width: 600px)\").matches;\n        const desktopContent = document.querySelector('.desktop-only');\n        const mobileContent = document.querySelector('.mobile-only');\n\n        if (isMobile) {\n           \n            console.log('');\n            \n            desktopContent.style.display = 'none';\n            mobileContent.style.display = 'block';\n        } else {\n       \n            console.log('');            \n           \n            desktopContent.style.display = 'block';\n            mobileContent.style.display = 'none';\n        }\n    \u003c\/script\u003e\n\n\n\n\u003c\/body\u003e","brand":"U.S. Solid","offers":[{"title":"110V AC \/ NPT","offer_id":47043371106559,"sku":"JFMSV20016","price":89.0,"currency_code":"USD","in_stock":true},{"title":"220V AC \/ G","offer_id":47043371139327,"sku":"JFMSV20016-G","price":89.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/7_aeabf986-ef9b-48f0-85e1-fa1d351d574e.png?v=1752720042"},{"product_id":"3-4-pvc-motorized-ball-valve-110v-ac-electric-ball-valve-auto-return-normally-closed","title":"3\/4\" PVC Motorized Ball Valve - 110\/220V AC Plastic Electric Ball Valve, Auto Return, Normally Closed","description":"\u003cbody\u003e \n\n\n    \u003cstyle\u003e\n        @media only screen and (max-width: 600px) {\n        }\n    \u003c\/style\u003e\n\n\n    \u003cdiv class=\"desktop-only\"\u003e\n     \n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; line-height: 26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 10px; color: black; font-family: Arial;\"\u003eMotorized ball valves present an energy-efficient substitute for solenoid valves, particularly when it comes to prolonged positioning. They primarily consume power during the processes of opening and closing, and the energy consumption is negligible once they are fully opened. This characteristic enables a permanent connection, eliminating the risks of overheating or burnout.\u003c\/p\u003e\n        \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/1.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n             \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n    \u003ctable style=\"border-collapse: collapse;\n                  border: 0px;\n                  width: 100%;\n                  font-family: Arial;\n                  overflow-x: auto;\n                  background-color: #FFFFFF;\"\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"width: 100%;text-align: left;\n                       padding: 0px;\n                       font-size: 16px;\n                       border: 0;\n                       background-color: #FFFFFF;\"\u003e\n                \u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 1\" style=\"width: 100%;height: 100%;\"\u003e\n            \u003c\/td\u003e\n            \u003ctd style=\"width: 100%;text-align: left;\n                       padding: 0px;\n                       font-size: 16px;\n                       border: 0;\n                       background-color: #FFFFFF;\"\u003e\n                \u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 2\" style=\"width: 100%;height: 100%;\"\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/table\u003e\n\u003c\/div\u003e\n          \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e \n \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV20017\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eU.S. Solid\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e3\/4\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eUS Plug\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eUPVC\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e6 - 8 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eAC 110V\/220V\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e5 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e3 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e0℃-90 ℃\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e70,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eStandard\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\/G\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNormally Closed\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e-10℃- 40 ℃\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eIP67\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/CE.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP67 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYES. The motorized ball valve is made of UPVC.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n    \u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP67 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP67. The first digit 6 indicates complete dust - tightness. The second digit 7 means protection from immersion(up to 1M) for a limited time. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/IP67-SS304.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/Manual%20for%20Tonhe.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n    \u003c\/div\u003e\n    \u003cdiv class=\"mobile-only\"\u003e\n        \n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; line-height:26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 0px; color: black; font-family: Arial;\"\u003eMotorized ball valves present an energy-efficient substitute for solenoid valves, particularly when it comes to prolonged positioning. They primarily consume power during the processes of opening and closing, and the energy consumption is negligible once they are fully opened. This characteristic enables a permanent connection, eliminating the risks of overheating or burnout.\u003c\/p\u003e\n            \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/1.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-bottom:10px; margin-top:20px; color: black;\"\u003e\u003cstrong\u003eAPPLICATION\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n    \u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 1\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n    \u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 2\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n\u003c\/div\u003e\n      \u003cp style=\"font-size: 16px; text-align: left; margin-bottom:10px; margin-top:20px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n       \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV20017\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eU.S. Solid\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e3\/4\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eUS Plug\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eUPVC\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e6 - 8 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eAC 110V\/220V\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e5 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e3 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e0℃-90 ℃\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e70,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eStandard\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\/G\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNormally Closed\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e-10℃- 40 ℃\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eIP67\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/CE.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n       \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP67 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYES. The motorized ball valve is made of UPVC.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n    \u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                 \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP67 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP67. The first digit 6 indicates complete dust - tightness. The second digit 7 means protection from immersion(up to 1M) for a limited time. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/IP67-SS304.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material-APP.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/Manual%20for%20Tonhe.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n    \u003cscript\u003e\n\n       \n        const isMobile = window.matchMedia(\"only screen and (max-width: 600px)\").matches;\n        const desktopContent = document.querySelector('.desktop-only');\n        const mobileContent = document.querySelector('.mobile-only');\n\n        if (isMobile) {\n           \n            console.log('');\n            \n            desktopContent.style.display = 'none';\n            mobileContent.style.display = 'block';\n        } else {\n       \n            console.log('');            \n           \n            desktopContent.style.display = 'block';\n            mobileContent.style.display = 'none';\n        }\n    \u003c\/script\u003e\n\n\n\n\u003c\/body\u003e","brand":"U.S. Solid","offers":[{"title":"110V AC \/ NPT","offer_id":47043371696383,"sku":"JFMSV20017","price":91.0,"currency_code":"USD","in_stock":true},{"title":"220V AC \/ G","offer_id":47043371729151,"sku":"JFMSV20017-G","price":91.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/7_2fc77ba1-15ee-4f86-82ed-7f6ba4e0db26.png?v=1752720143"},{"product_id":"1-pvc-motorized-ball-valve-110v-ac-electric-ball-valve-auto-return-normally-closed","title":"1\" PVC Motorized Ball Valve - 110\/220V AC Plastic Electric Ball Valve, Auto Return, Normally Closed","description":"\u003cbody\u003e \n\n\n    \u003cstyle\u003e\n        @media only screen and (max-width: 600px) {\n        }\n    \u003c\/style\u003e\n\n\n    \u003cdiv class=\"desktop-only\"\u003e\n     \n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; line-height: 26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 10px; color: black; font-family: Arial;\"\u003eMotorized ball valves present an energy-efficient substitute for solenoid valves, particularly when it comes to prolonged positioning. They primarily consume power during the processes of opening and closing, and the energy consumption is negligible once they are fully opened. This characteristic enables a permanent connection, eliminating the risks of overheating or burnout.\u003c\/p\u003e\n        \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/1.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n             \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n    \u003ctable style=\"border-collapse: collapse;\n                  border: 0px;\n                  width: 100%;\n                  font-family: Arial;\n                  overflow-x: auto;\n                  background-color: #FFFFFF;\"\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"width: 100%;text-align: left;\n                       padding: 0px;\n                       font-size: 16px;\n                       border: 0;\n                       background-color: #FFFFFF;\"\u003e\n                \u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 1\" style=\"width: 100%;height: 100%;\"\u003e\n            \u003c\/td\u003e\n            \u003ctd style=\"width: 100%;text-align: left;\n                       padding: 0px;\n                       font-size: 16px;\n                       border: 0;\n                       background-color: #FFFFFF;\"\u003e\n                \u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 2\" style=\"width: 100%;height: 100%;\"\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/table\u003e\n\u003c\/div\u003e\n          \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e \n \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV20018\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eU.S. Solid\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eUS Plug\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eUPVC\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e6 - 8 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eAC 110V\/220V\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e5 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e3 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e0℃-90 ℃\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e70,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eStandard\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\/G\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNormally Closed\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e-10℃- 40 ℃\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eIP67\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/CE.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP67 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYES. The motorized ball valve is made of UPVC.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n    \u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP67 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP67. The first digit 6 indicates complete dust - tightness. The second digit 7 means protection from immersion(up to 1M) for a limited time. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/IP67-SS304.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/Manual%20for%20Tonhe.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n    \u003c\/div\u003e\n    \u003cdiv class=\"mobile-only\"\u003e\n        \n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; line-height:26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 0px; color: black; font-family: Arial;\"\u003eMotorized ball valves present an energy-efficient substitute for solenoid valves, particularly when it comes to prolonged positioning. They primarily consume power during the processes of opening and closing, and the energy consumption is negligible once they are fully opened. This characteristic enables a permanent connection, eliminating the risks of overheating or burnout.\u003c\/p\u003e\n            \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/1.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-bottom:10px; margin-top:20px; color: black;\"\u003e\u003cstrong\u003eAPPLICATION\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n    \u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 1\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n    \u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 2\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n\u003c\/div\u003e\n      \u003cp style=\"font-size: 16px; text-align: left; margin-bottom:10px; margin-top:20px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n       \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV20018\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eU.S. Solid\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eUS Plug\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eUPVC\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e6 - 8 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eAC 110V\/220V\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e5 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e3 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e0℃-90 ℃\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e70,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eStandard\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\/G\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNormally Closed\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e-10℃- 40 ℃\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eIP67\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/CE.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n       \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP67 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYES. The motorized ball valve is made of UPVC.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n    \u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                 \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP67 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP67. The first digit 6 indicates complete dust - tightness. The second digit 7 means protection from immersion(up to 1M) for a limited time. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/IP67-SS304.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material-APP.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/Manual%20for%20Tonhe.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n    \u003cscript\u003e\n\n       \n        const isMobile = window.matchMedia(\"only screen and (max-width: 600px)\").matches;\n        const desktopContent = document.querySelector('.desktop-only');\n        const mobileContent = document.querySelector('.mobile-only');\n\n        if (isMobile) {\n           \n            console.log('');\n            \n            desktopContent.style.display = 'none';\n            mobileContent.style.display = 'block';\n        } else {\n       \n            console.log('');            \n           \n            desktopContent.style.display = 'block';\n            mobileContent.style.display = 'none';\n        }\n    \u003c\/script\u003e\n\n\n\n\u003c\/body\u003e","brand":"U.S. Solid","offers":[{"title":"110V AC \/ NPT","offer_id":47043372056831,"sku":"JFMSV20018","price":94.0,"currency_code":"USD","in_stock":true},{"title":"220V AC \/ G","offer_id":47043372089599,"sku":"JFMSV20018-G","price":94.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/7_d60840f5-b6b0-410e-936f-6bf54a649cfb.png?v=1752719424"},{"product_id":"1-1-4-double-union-upvc-motorized-ball-valve-dc-24v-2-wire-auto-return-normally-closed-with-manual-override-epdm-seal","title":"1-1\/4\" Double Union UPVC Motorized Ball Valve - DC 24V, 2-Wire Auto Return, Normally Closed with Manual Override \u0026 EPDM Seal","description":"\u003cbody\u003e\n    \u003cmeta charset=\"UTF-8\"\u003e\n    \u003cmeta name=\"viewport\" content=\"width=device-width, initial-scale=1.0\"\u003e\n    \u003ctitle\u003eResponsive Page with Multiple Modules\u003c\/title\u003e\n    \u003cstyle\u003e\n\n        .desktop-img {\n            display: block;\n        }\n        .mobile-img {\n            display: none;\n        }\n\n        .section-title {\n            font-size: 22px;\n            line-height: 22px;\n            font-weight: bold;\n            margin: 15px 0 5px;\n            font-family: Arial;\n        }\n\n        .section-title2 {\n            font-size: 22px;\n            line-height: 22px;\n            font-weight: bold;\n            margin: 15px 0 3px;\n            font-family: Arial;\n        }\n\n        .section-title3 {\n            font-size: 22px;\n            line-height: 22px;\n            font-weight: bold;\n            margin: 15px 0 10px;\n            font-family: Arial;\n        }\n\n        .section-description {\n            font-size: 16px;\n            line-height: 26px;\n            margin-top: 0px;\n            margin-bottom: 5px;\n            font-family: Arial;\n        }\n\n        .faq {\n            font-size: 16px;\n            margin: 0;\n            line-height: 26px;\n            background-color: #f2f2f2;\n            padding: 5px;\n        }\n\n        .section-description2 {\n            font-size: 16px;\n            line-height: 26px;\n            margin: 0px;\n            font-family: Arial;\n        }\n\n        .parameters-table-wrapper {\n            overflow-x: auto;\n            -webkit-overflow-scrolling: touch;\n            margin-top: 0px;\n        }\n\n        .parameters-table {\n            width: 100%;\n            min-width: 1000px;\n            border-collapse: collapse;\n            margin-top: 0px;\n        }\n\n        .parameters-table th, .parameters-table td {\n            border-top: 1.2px solid #a6a6a6;\n            border-bottom: 1.2px solid #a6a6a6;\n            border-left: none;\n            border-right: none;\n            padding: 5px 2px;\n            text-align: left;\n            font-size: 16px;\n            line-height: 16px;\n        }\n\n        .parameters-table th {\n            background-color: #f2f2f2;\n            color: #2c2c2c;\n            font-weight: bold;\n        }\n\n        .parameters-table .bg-gray {\n            background-color: #f2f2f2;\n        }\n\n        .options-table-wrapper {\n            overflow-x: auto;\n            -webkit-overflow-scrolling: touch;\n            margin-top: 0px;\n        }\n\n        .options-table {\n            width: 100%;\n            min-width: 1000px;\n            border-collapse: collapse;\n            margin-top: 0px;\n            box-shadow: 0 6px 25px rgba(0, 0, 0, 0.1);\n        }\n\n        .options-table th, .options-table td {\n            border: 2px solid #000;\n            padding: 5px 2px;\n            text-align: center;\n            font-size: 16px;\n            line-height: 16px;\n        }\n\n        .options-table th {\n            background-color: #f2f2f2;\n            color: #2c2c2c;\n            font-weight: bold;\n        }\n\n        .parameters-table2 {\n            width: 100%;\n            min-width: 1000px;\n            border-collapse: collapse;\n            margin-top: 0px;\n        }\n\n        .parameters-table2 th, .parameters-table2 td {\n            border-top: 1.2px solid #a6a6a6;\n            border-bottom: 1.2px solid #a6a6a6;\n            border-left: none;\n            border-right: none;\n            padding: 5px 2px;\n            text-align: center;\n            font-size: 16px;\n            line-height: 16px;\n        }\n\n        .parameters-table2 th {\n            background-color: #f2f2f2;\n            color: #2c2c2c;\n            font-weight: bold;\n        }\n\n        .parameters-table2 .bg-gray {\n            background-color: #f2f2f2;\n        }\n\n        .options-table-wrapper2 {\n            overflow-x: auto;\n            -webkit-overflow-scrolling: touch;\n            margin-top: 0px;\n        }\n\n        .instruction-container {\n            display: flex;\n            justify-content: space-between;\n            align-items: flex-start;\n            gap: 10px;\n            margin-bottom: 0px;\n        }\n\n        .img-container {\n            width: 35%;\n            display: flex;\n            justify-content: center;\n        }\n\n        .text-container {\n            width: 65%;\n            font-size: 16px;\n            font-family: Arial;\n        }\n\n        .instruction-container2 {\n            display: flex;\n            justify-content: space-between;\n            align-items: flex-start;\n            gap: 10px;\n            margin-bottom: 0px;\n        }\n\n        .img-container2 {\n            width: 50%;\n            display: flex;\n            justify-content: center;\n        }\n\n        .text-container2 {\n            width: 50%;\n            display: flex;\n            justify-content: center;\n        }\n\n        @media (max-width: 768px) {\n            .parameters-table th, .parameters-table td {\n                font-size: 14px;\n                padding: 8px 4px;\n            }\n\n            .options-table th, .options-table td {\n                font-size: 14px;\n                padding: 8px 4px;\n            }\n\n            .parameters-table-wrapper {\n                overflow-x: auto;\n            }\n\n            .parameters-table2 th, .parameters-table2 td {\n                font-size: 14px;\n                padding: 8px 4px;\n            }\n\n            .parameters-table-wrapper2 {\n                overflow-x: auto;\n            }\n\n            .desktop-img {\n                display: none;\n            }\n\n            .mobile-img {\n                display: block;\n            }\n\n            .instruction-container {\n                flex-direction: column;\n                align-items: center;\n            }\n\n            .img-container, .text-container {\n                width: 100%;\n                margin-bottom: 0px;\n            }\n\n            .instruction-container2 {\n                flex-direction: column;\n                align-items: center;\n            }\n\n            .img-container2, .text-container2 {\n                width: 100%;\n                margin-bottom: 0px;\n            }\n        }\n\n        @media (max-width: 480px) {\n            .parameters-table th, .parameters-table td {\n                font-size: 12px;\n                padding: 6px 3px;\n            }\n\n            .options-table th, .options-table td {\n                font-size: 12px;\n            }\n\n            .parameters-table-wrapper {\n                overflow-x: auto;\n            }\n\n            .parameters-table2 th, .parameters-table2 td {\n                font-size: 12px;\n                padding: 6px 3px;\n            }\n\n            .parameters-table-wrapper2 {\n                overflow-x: auto;\n            }\n\n            .desktop-img {\n                display: none;\n            }\n\n            .mobile-img {\n                display: block;\n            }\n\n            .instruction-container {\n                flex-direction: column;\n            }\n\n            .instruction-container2 {\n                flex-direction: column;\n            }\n        }\n\n    \u003c\/style\u003e\n\n\u003c!-- Background --\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/UPVC2\/b.jpg\" class=\"desktop-img\" alt=\"Desktop Image 1\"\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/UPVC2\/b-p.jpg\" class=\"mobile-img\" alt=\"Mobile Image 1\"\u003e\n\u003c!-- Introduction - 2-Wire Auto Return \/ Standard --\u003e\n\u003cdiv\u003e\n    \u003ch2 class=\"section-title\"\u003eIntroduction\u003c\/h2\u003e\n    \u003cp class=\"section-description\"\u003e\n        Our electric UPVC ball valve series has been upgraded to include three larger sizes: 1-1\/4\", 1-1\/2\", and 2\". These larger valves feature a unique \u003cstrong\u003e\u003cu\u003eUS standard socket end \u0026amp; double union connection\u003c\/u\u003e\u003c\/strong\u003e—enabling exceptional ease of installation and maintenance with a simple solvent cement bond, \u003cstrong\u003e\u003cu\u003eunlike\u003c\/u\u003e\u003c\/strong\u003e threaded NPT or G connections. For other connection standards, please contact our customer service.\u003cbr\u003eThese valves are \u003cstrong\u003e\u003cu\u003e2-wire auto return\u003c\/u\u003e\u003c\/strong\u003e and remain in a normally-closed position. They automatically close if power is lost. A manual override is also included for use during power outages. All valves have EPDM seals for reliable performance.\n    \u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- Applications--\u003e\n     \u003ch2 class=\"section-title2\"\u003eApplications\u003c\/h2\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/UPVC2\/a.jpg\" class=\"desktop-img\" alt=\"Desktop Image 1\"\u003e\n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/UPVC2\/a-p.jpg\" class=\"mobile-img\" alt=\"Desktop Image 2\"\u003e\n\u003c!-- Features - 2-Wire Auto Return --\u003e\n\u003cdiv\u003e\n    \u003ch2 class=\"section-title\"\u003eFeatures\u003c\/h2\u003e\n    \u003cul class=\"section-description2\"\u003e\n        \u003cli\u003e\n\u003cstrong\u003eUnion \u0026amp; Socket End:\u003c\/strong\u003e Different from standard NPT\/G threaded connections, it uses socket-gluing for sealing and integrates threaded structures, balancing connection stability with quick disassembly and maintenance needs.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eManual Function:\u003c\/strong\u003e Comes with a hex wrench as standard; allows manual valve opening and closing during power outages. \"O\"=Open, \"S\"=Close.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eIndicator Window:\u003c\/strong\u003e Built-in engraved marks directly show the valve's open\/closed status. External arrow pointing to \"0\" means fully closed; pointing to \"90\" means fully open.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003ePremium Material:\u003c\/strong\u003e Valve body made of UPVC with EPDM seals, meeting general operating requirements.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003e2-Wire Auto Return:\u003c\/strong\u003e Uses a 2-wire auto-return configuration. The valve remains normally closed and automatically closes when power is lost, making it suitable for fail-safe applications.\u003c\/li\u003e\n    \u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/UPVC2\/2-Return.jpg\" class=\"desktop-img\" alt=\"Desktop Image 1\"\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/UPVC2\/2-Return-p.jpg\" class=\"mobile-img\" alt=\"Desktop Image 2\"\u003e\n\u003c!-- User Manual --\u003e\n\u003cdiv\u003e\n    \u003ch2 class=\"section-title\"\u003eUser Manual\u003c\/h2\u003e\n    \u003cp class=\"section-description\"\u003e\n        To learn how to use this product, please refer to the \u003ca href=\"https:\/\/file.ussolid.com\/content\/JFMSV\/Manual-%20USS-UPVC.pdf\" target=\"_blank\"\u003euser manual\u003c\/a\u003e.\n    \u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- Technical Data --\u003e\n    \u003ch2 class=\"section-title3\"\u003eTechnical Data\u003c\/h2\u003e \n    \u003cdiv class=\"parameters-table-wrapper\"\u003e\n        \u003ctable class=\"parameters-table\"\u003e\n            \u003ctbody\u003e \n                \u003ctr\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003ePort Size\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003e1 1\/4\"\u003c\/td\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003eUSS-MSV467\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003ePort\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003e2 Way\u003c\/td\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eThread\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003eNo Thread\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eConnection\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003eUnion \u0026amp; Socket End\u003c\/td\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eMax Power\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003e36W\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eSocket Inside Diameter\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003e42.2mm (US Standard)\u003c\/td\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eWith Hex Wrench\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003eYes\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eWiring\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003e2-Wire Auto Return\u003c\/td\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eManual Function\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003eYes\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eSignal feedback function\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003eNo\u003c\/td\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eIndicator Window\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003eYes\u003c\/td\u003e\n                \u003c\/tr\u003e\n\n                \u003ctr\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eBody Material\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003eUPVC\u003c\/td\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eNormal Position\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003eNormally Closed\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eSeal Material\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003eEPDM\u003c\/td\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eTemp Range (Medium)\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003e33.8℉ to 104℉\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eWorking Voltage\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003eDC 24V\u003c\/td\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eClose\/Open Time\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003e10-12s\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eMax Torque\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003e20 N·m\u003c\/td\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eMax. Pressure\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003e232 psi\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eLife Expectancy\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003e20,000 Cycles\u003c\/td\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eIP Rating\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003eIP65\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003ePackage Size\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003e9.1\"x7.1\"x4.7\"\u003c\/td\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eGross Weight\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003e3.31 lb\u003c\/td\u003e\n                \u003c\/tr\u003e \n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n    \u003cp class=\"section-description\"\u003e*To view the full table on mobile, please swipe left or right on the screen.\u003c\/p\u003e\n\u003c!-- Wiring - 2-Wire Auto Return --\u003e\n\u003ch2 class=\"section-title\"\u003e2-Wire Auto Return\u003c\/h2\u003e\n\u003cdiv class=\"instruction-container\"\u003e\n    \u003cdiv class=\"img-container\"\u003e\n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Wire\/return.jpg\" alt=\"\" style=\"width: 100%; height: auto;\"\u003e\n    \u003c\/div\u003e\n    \u003cdiv class=\"text-container\"\u003e\n        \u003cp class=\"section-description\"\u003e\n            This model uses a 2-wire auto-return wiring method. It is normally closed by default: the valve opens when powered and automatically returns to the closed position when power is lost or disconnected.\n        \u003c\/p\u003e\n        \u003cul class=\"section-description2\"\u003e\n            \u003cli\u003eFor the basic version without signal feedback, simply ignore the signal wire connections shown in the diagram.\u003c\/li\u003e\n            \u003cli\u003eWire Color Coding: BK (Black), RD (Red), YW (Yellow), WT (White), BU (Blue), GN (Green), and OG (Orange).\u003c\/li\u003e\n            \u003cli\u003eFor reliable auto-reset performance, power the valve for at least 60 seconds (≥60s) during first commissioning or after a prolonged power cut.\u003c\/li\u003e\n            \u003cli\u003eBefore manual operation, disconnect power and wait briefly for the actuator to discharge.\u003c\/li\u003e\n        \u003c\/ul\u003e\n    \u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- FAQ --\u003e\n\u003cdiv\u003e\n    \u003ch2 class=\"section-title\"\u003eFAQ\u003c\/h2\u003e\n    \u003cp class=\"faq\"\u003e\u003cb\u003eProblem 1: What is unique about the connection method of this ball valve?\u003c\/b\u003e\u003c\/p\u003e\n    \u003cdiv class=\"instruction-container\"\u003e\n        \u003cdiv class=\"img-container\"\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/UPVC2\/size-2.jpg\" alt=\"\" style=\"width: 100%; height: auto;\"\u003e\n        \u003c\/div\u003e\n        \u003cdiv class=\"text-container\"\u003e\n            \u003cp class=\"section-description\"\u003e\n                The larger sizes of our ball valve series (1-1\/4\", 1-1\/2\", and 2\") come standard with \u003cstrong\u003e\u003cu\u003eSocket End ports\u003c\/u\u003e\u003c\/strong\u003e for solvent cement bonding and a \u003cstrong\u003e\u003cu\u003eUnion structure\u003c\/u\u003e\u003c\/strong\u003e for easier installation and maintenance, instead of common threaded connections such as NPT or G.\u003cbr\u003e\n                This union design allows the valve body to be installed or removed more easily for maintenance or replacement, without cutting the pipe or rotating the valve body itself.\u003cbr\u003e\n                The pipe sockets are made to a \u003cstrong\u003e\u003cu\u003eUS standard\u003c\/u\u003e\u003c\/strong\u003e. Please note that the Socket Inside Diameter (I.D.) may vary by national standard even for the same nominal size, such as 1-1\/4\". For other connection standards, including British Standard, Japanese Industrial Standard, or others, please contact our customer service team.\n            \u003c\/p\u003e\n        \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cp class=\"faq\"\u003e\u003cb\u003eProblem 2: What precautions apply to auto-return models?\u003c\/b\u003e\u003c\/p\u003e\n    \u003cp class=\"section-description\"\u003e\n        The auto-return ball valve requires a minimum power-on duration of 60 seconds (≥60s). This step is mandatory during first commissioning or after a prolonged power cut to ensure reliable auto-reset performance. Before using the manual override, always disconnect the power first. For auto-return models, please wait for a short period after power is disconnected before manual operation, as the actuator needs time to discharge; otherwise, the valve may be difficult to turn manually.\n    \u003c\/p\u003e\n\n    \u003cp class=\"faq\"\u003e\u003cb\u003eProblem 3: Does this model come with a manual function?\u003c\/b\u003e\u003c\/p\u003e\n    \u003cp class=\"section-description\"\u003e\n        \u003cstrong\u003eYes.\u003c\/strong\u003e The manual override function allows you to control the opening and closing of the valve during a power outage. A hexagonal wrench is included with the valve for this purpose.\n    \u003c\/p\u003e\n\n    \u003cp class=\"faq\"\u003e\u003cb\u003eProblem 4: What should be noted during manual operation?\u003c\/b\u003e\u003c\/p\u003e\n    \u003cp class=\"section-description\"\u003e\n        Power must be disconnected before manual operation. Turn the valve according to the \"O\" and \"S\" indicators: \"O\" = Open, \"S\" = Close. The valve should be turned fully open or fully closed; do not leave it in a middle position, as this may damage the valve. For auto-return models, wait for a short period after disconnecting power before manual operation.\n    \u003c\/p\u003e\n\n    \u003cp class=\"faq\"\u003e\u003cb\u003eProblem 5: How to read the indicator window?\u003c\/b\u003e\u003c\/p\u003e\n    \u003cp class=\"section-description\"\u003e\n        The external arrow shows the valve position. When the arrow points to \"0\", the valve is fully closed; when it points to \"90\", the valve is fully open.\n    \u003c\/p\u003e\n\n    \u003cp class=\"faq\"\u003e\u003cb\u003eProblem 6: What is a Union connection?\u003c\/b\u003e\u003c\/p\u003e\n    \u003cp class=\"section-description\"\u003e\n        A Union connection is a detachable valve structure that allows the valve body to be removed more easily for maintenance or replacement without cutting the pipe. On this product, the pipe connection ends are Socket End ports designed for solvent cement bonding.\n    \u003c\/p\u003e\n\n    \u003cp class=\"faq\"\u003e\u003cb\u003eProblem 7: What should be noted about the four main control methods?\u003c\/b\u003e\u003c\/p\u003e\n    \u003cp class=\"section-description\"\u003e\n        Please pay attention to the wiring type when purchasing. Only auto-return models will automatically return to the closed position when power is lost. Other control methods do not automatically reset after power loss and will remain in their current position.\n    \u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/body\u003e","brand":"U.S. Solid","offers":[{"title":"Default Title","offer_id":47291316142335,"sku":"JFMSV00467","price":161.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/1_e994c5be-5ae2-4c5a-ba29-8d05f9297e7b.jpg?v=1758694453"},{"product_id":"1-1-2-double-union-upvc-motorized-ball-valve-dc-24v-2-wire-auto-return-normally-closed-with-manual-override-epdm-seal","title":"1-1\/2\" Double Union UPVC Motorized Ball Valve - DC 24V, 2-Wire Auto Return, Normally Closed with Manual Override \u0026 EPDM Seal","description":"\u003cbody\u003e\n    \u003cmeta charset=\"UTF-8\"\u003e\n    \u003cmeta name=\"viewport\" content=\"width=device-width, initial-scale=1.0\"\u003e\n    \u003ctitle\u003eResponsive Page with Multiple Modules\u003c\/title\u003e\n    \u003cstyle\u003e\n\n        .desktop-img {\n            display: block;\n        }\n        .mobile-img {\n            display: none;\n        }\n\n        .section-title {\n            font-size: 22px;\n            line-height: 22px;\n            font-weight: bold;\n            margin: 15px 0 5px;\n            font-family: Arial;\n        }\n\n        .section-title2 {\n            font-size: 22px;\n            line-height: 22px;\n            font-weight: bold;\n            margin: 15px 0 3px;\n            font-family: Arial;\n        }\n\n        .section-title3 {\n            font-size: 22px;\n            line-height: 22px;\n            font-weight: bold;\n            margin: 15px 0 10px;\n            font-family: Arial;\n        }\n\n        .section-description {\n            font-size: 16px;\n            line-height: 26px;\n            margin-top: 0px;\n            margin-bottom: 5px;\n            font-family: Arial;\n        }\n\n        .faq {\n            font-size: 16px;\n            margin: 0;\n            line-height: 26px;\n            background-color: #f2f2f2;\n            padding: 5px;\n        }\n\n        .section-description2 {\n            font-size: 16px;\n            line-height: 26px;\n            margin: 0px;\n            font-family: Arial;\n        }\n\n        .parameters-table-wrapper {\n            overflow-x: auto;\n            -webkit-overflow-scrolling: touch;\n            margin-top: 0px;\n        }\n\n        .parameters-table {\n            width: 100%;\n            min-width: 1000px;\n            border-collapse: collapse;\n            margin-top: 0px;\n        }\n\n        .parameters-table th, .parameters-table td {\n            border-top: 1.2px solid #a6a6a6;\n            border-bottom: 1.2px solid #a6a6a6;\n            border-left: none;\n            border-right: none;\n            padding: 5px 2px;\n            text-align: left;\n            font-size: 16px;\n            line-height: 16px;\n        }\n\n        .parameters-table th {\n            background-color: #f2f2f2;\n            color: #2c2c2c;\n            font-weight: bold;\n        }\n\n        .parameters-table .bg-gray {\n            background-color: #f2f2f2;\n        }\n\n        .options-table-wrapper {\n            overflow-x: auto;\n            -webkit-overflow-scrolling: touch;\n            margin-top: 0px;\n        }\n\n        .options-table {\n            width: 100%;\n            min-width: 1000px;\n            border-collapse: collapse;\n            margin-top: 0px;\n            box-shadow: 0 6px 25px rgba(0, 0, 0, 0.1);\n        }\n\n        .options-table th, .options-table td {\n            border: 2px solid #000;\n            padding: 5px 2px;\n            text-align: center;\n            font-size: 16px;\n            line-height: 16px;\n        }\n\n        .options-table th {\n            background-color: #f2f2f2;\n            color: #2c2c2c;\n            font-weight: bold;\n        }\n\n        .parameters-table2 {\n            width: 100%;\n            min-width: 1000px;\n            border-collapse: collapse;\n            margin-top: 0px;\n        }\n\n        .parameters-table2 th, .parameters-table2 td {\n            border-top: 1.2px solid #a6a6a6;\n            border-bottom: 1.2px solid #a6a6a6;\n            border-left: none;\n            border-right: none;\n            padding: 5px 2px;\n            text-align: center;\n            font-size: 16px;\n            line-height: 16px;\n        }\n\n        .parameters-table2 th {\n            background-color: #f2f2f2;\n            color: #2c2c2c;\n            font-weight: bold;\n        }\n\n        .parameters-table2 .bg-gray {\n            background-color: #f2f2f2;\n        }\n\n        .options-table-wrapper2 {\n            overflow-x: auto;\n            -webkit-overflow-scrolling: touch;\n            margin-top: 0px;\n        }\n\n        .instruction-container {\n            display: flex;\n            justify-content: space-between;\n            align-items: flex-start;\n            gap: 10px;\n            margin-bottom: 0px;\n        }\n\n        .img-container {\n            width: 35%;\n            display: flex;\n            justify-content: center;\n        }\n\n        .text-container {\n            width: 65%;\n            font-size: 16px;\n            font-family: Arial;\n        }\n\n        .instruction-container2 {\n            display: flex;\n            justify-content: space-between;\n            align-items: flex-start;\n            gap: 10px;\n            margin-bottom: 0px;\n        }\n\n        .img-container2 {\n            width: 50%;\n            display: flex;\n            justify-content: center;\n        }\n\n        .text-container2 {\n            width: 50%;\n            display: flex;\n            justify-content: center;\n        }\n\n        @media (max-width: 768px) {\n            .parameters-table th, .parameters-table td {\n                font-size: 14px;\n                padding: 8px 4px;\n            }\n\n            .options-table th, .options-table td {\n                font-size: 14px;\n                padding: 8px 4px;\n            }\n\n            .parameters-table-wrapper {\n                overflow-x: auto;\n            }\n\n            .parameters-table2 th, .parameters-table2 td {\n                font-size: 14px;\n                padding: 8px 4px;\n            }\n\n            .parameters-table-wrapper2 {\n                overflow-x: auto;\n            }\n\n            .desktop-img {\n                display: none;\n            }\n\n            .mobile-img {\n                display: block;\n            }\n\n            .instruction-container {\n                flex-direction: column;\n                align-items: center;\n            }\n\n            .img-container, .text-container {\n                width: 100%;\n                margin-bottom: 0px;\n            }\n\n            .instruction-container2 {\n                flex-direction: column;\n                align-items: center;\n            }\n\n            .img-container2, .text-container2 {\n                width: 100%;\n                margin-bottom: 0px;\n            }\n        }\n\n        @media (max-width: 480px) {\n            .parameters-table th, .parameters-table td {\n                font-size: 12px;\n                padding: 6px 3px;\n            }\n\n            .options-table th, .options-table td {\n                font-size: 12px;\n            }\n\n            .parameters-table-wrapper {\n                overflow-x: auto;\n            }\n\n            .parameters-table2 th, .parameters-table2 td {\n                font-size: 12px;\n                padding: 6px 3px;\n            }\n\n            .parameters-table-wrapper2 {\n                overflow-x: auto;\n            }\n\n            .desktop-img {\n                display: none;\n            }\n\n            .mobile-img {\n                display: block;\n            }\n\n            .instruction-container {\n                flex-direction: column;\n            }\n\n            .instruction-container2 {\n                flex-direction: column;\n            }\n        }\n\n    \u003c\/style\u003e\n\n\u003c!-- Background --\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/UPVC2\/b.jpg\" class=\"desktop-img\" alt=\"Desktop Image 1\"\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/UPVC2\/b-p.jpg\" class=\"mobile-img\" alt=\"Mobile Image 1\"\u003e\n\u003c!-- Introduction - 2-Wire Auto Return \/ Standard --\u003e\n\u003cdiv\u003e\n    \u003ch2 class=\"section-title\"\u003eIntroduction\u003c\/h2\u003e\n    \u003cp class=\"section-description\"\u003e\n        Our electric UPVC ball valve series has been upgraded to include three larger sizes: 1-1\/4\", 1-1\/2\", and 2\". These larger valves feature a unique \u003cstrong\u003e\u003cu\u003eUS standard socket end \u0026amp; double union connection\u003c\/u\u003e\u003c\/strong\u003e—enabling exceptional ease of installation and maintenance with a simple solvent cement bond, \u003cstrong\u003e\u003cu\u003eunlike\u003c\/u\u003e\u003c\/strong\u003e threaded NPT or G connections. For other connection standards, please contact our customer service.\u003cbr\u003eThese valves are \u003cstrong\u003e\u003cu\u003e2-wire auto return\u003c\/u\u003e\u003c\/strong\u003e and remain in a normally-closed position. They automatically close if power is lost. A manual override is also included for use during power outages. All valves have EPDM seals for reliable performance.\n    \u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- Applications--\u003e\n     \u003ch2 class=\"section-title2\"\u003eApplications\u003c\/h2\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/UPVC2\/a.jpg\" class=\"desktop-img\" alt=\"Desktop Image 1\"\u003e\n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/UPVC2\/a-p.jpg\" class=\"mobile-img\" alt=\"Desktop Image 2\"\u003e\n\u003c!-- Features - 2-Wire Auto Return --\u003e\n\u003cdiv\u003e\n    \u003ch2 class=\"section-title\"\u003eFeatures\u003c\/h2\u003e\n    \u003cul class=\"section-description2\"\u003e\n        \u003cli\u003e\n\u003cstrong\u003eUnion \u0026amp; Socket End:\u003c\/strong\u003e Different from standard NPT\/G threaded connections, it uses socket-gluing for sealing and integrates threaded structures, balancing connection stability with quick disassembly and maintenance needs.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eManual Function:\u003c\/strong\u003e Comes with a hex wrench as standard; allows manual valve opening and closing during power outages. \"O\"=Open, \"S\"=Close.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eIndicator Window:\u003c\/strong\u003e Built-in engraved marks directly show the valve's open\/closed status. External arrow pointing to \"0\" means fully closed; pointing to \"90\" means fully open.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003ePremium Material:\u003c\/strong\u003e Valve body made of UPVC with EPDM seals, meeting general operating requirements.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003e2-Wire Auto Return:\u003c\/strong\u003e Uses a 2-wire auto-return configuration. The valve remains normally closed and automatically closes when power is lost, making it suitable for fail-safe applications.\u003c\/li\u003e\n    \u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/UPVC2\/2-Return.jpg\" class=\"desktop-img\" alt=\"Desktop Image 1\"\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/UPVC2\/2-Return-p.jpg\" class=\"mobile-img\" alt=\"Desktop Image 2\"\u003e\n\u003c!-- User Manual --\u003e\n\u003cdiv\u003e\n    \u003ch2 class=\"section-title\"\u003eUser Manual\u003c\/h2\u003e\n    \u003cp class=\"section-description\"\u003e\n        To learn how to use this product, please refer to the \u003ca href=\"https:\/\/file.ussolid.com\/content\/JFMSV\/Manual-%20USS-UPVC.pdf\" target=\"_blank\"\u003euser manual\u003c\/a\u003e.\n    \u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- Technical Data --\u003e\n    \u003ch2 class=\"section-title3\"\u003eTechnical Data\u003c\/h2\u003e \n    \u003cdiv class=\"parameters-table-wrapper\"\u003e\n        \u003ctable class=\"parameters-table\"\u003e\n            \u003ctbody\u003e \n                \u003ctr\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003ePort Size\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003e1 1\/2\"\u003c\/td\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003eUSS-MSV468\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003ePort\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003e2 Way\u003c\/td\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eThread\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003eNo Thread\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eConnection\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003eUnion \u0026amp; Socket End\u003c\/td\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eMax Power\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003e36W\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eSocket Inside Diameter\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003e48.3mm (US Standard)\u003c\/td\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eWith Hex Wrench\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003eYes\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eWiring\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003e2-Wire Auto Return\u003c\/td\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eManual Function\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003eYes\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eSignal feedback function\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003eNo\u003c\/td\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eIndicator Window\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003eYes\u003c\/td\u003e\n                \u003c\/tr\u003e\n\n                \u003ctr\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eBody Material\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003eUPVC\u003c\/td\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eNormal Position\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003eNormally Closed\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eSeal Material\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003eEPDM\u003c\/td\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eTemp Range (Medium)\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003e33.8℉ to 104℉\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eWorking Voltage\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003eDC 24V\u003c\/td\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eClose\/Open Time\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003e10-12s\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eMax Torque\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003e20 N·m\u003c\/td\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eMax. Pressure\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003e232 psi\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eLife Expectancy\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003e20,000 Cycles\u003c\/td\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eIP Rating\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003eIP65\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003ePackage Size\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003e9.1\"x7.1\"x4.7\"\u003c\/td\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eGross Weight\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003e3.97 lb\u003c\/td\u003e\n                \u003c\/tr\u003e \n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n    \u003cp class=\"section-description\"\u003e*To view the full table on mobile, please swipe left or right on the screen.\u003c\/p\u003e\n\u003c!-- Wiring - 2-Wire Auto Return --\u003e\n\u003ch2 class=\"section-title\"\u003e2-Wire Auto Return\u003c\/h2\u003e\n\u003cdiv class=\"instruction-container\"\u003e\n    \u003cdiv class=\"img-container\"\u003e\n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Wire\/return.jpg\" alt=\"\" style=\"width: 100%; height: auto;\"\u003e\n    \u003c\/div\u003e\n    \u003cdiv class=\"text-container\"\u003e\n        \u003cp class=\"section-description\"\u003e\n            This model uses a 2-wire auto-return wiring method. It is normally closed by default: the valve opens when powered and automatically returns to the closed position when power is lost or disconnected.\n        \u003c\/p\u003e\n        \u003cul class=\"section-description2\"\u003e\n            \u003cli\u003eFor the basic version without signal feedback, simply ignore the signal wire connections shown in the diagram.\u003c\/li\u003e\n            \u003cli\u003eWire Color Coding: BK (Black), RD (Red), YW (Yellow), WT (White), BU (Blue), GN (Green), and OG (Orange).\u003c\/li\u003e\n            \u003cli\u003eFor reliable auto-reset performance, power the valve for at least 60 seconds (≥60s) during first commissioning or after a prolonged power cut.\u003c\/li\u003e\n            \u003cli\u003eBefore manual operation, disconnect power and wait briefly for the actuator to discharge.\u003c\/li\u003e\n        \u003c\/ul\u003e\n    \u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- FAQ --\u003e\n\u003cdiv\u003e\n    \u003ch2 class=\"section-title\"\u003eFAQ\u003c\/h2\u003e\n    \u003cp class=\"faq\"\u003e\u003cb\u003eProblem 1: What is unique about the connection method of this ball valve?\u003c\/b\u003e\u003c\/p\u003e\n    \u003cdiv class=\"instruction-container\"\u003e\n        \u003cdiv class=\"img-container\"\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/UPVC2\/size-2.jpg\" alt=\"\" style=\"width: 100%; height: auto;\"\u003e\n        \u003c\/div\u003e\n        \u003cdiv class=\"text-container\"\u003e\n            \u003cp class=\"section-description\"\u003e\n                The larger sizes of our ball valve series (1-1\/4\", 1-1\/2\", and 2\") come standard with \u003cstrong\u003e\u003cu\u003eSocket End ports\u003c\/u\u003e\u003c\/strong\u003e for solvent cement bonding and a \u003cstrong\u003e\u003cu\u003eUnion structure\u003c\/u\u003e\u003c\/strong\u003e for easier installation and maintenance, instead of common threaded connections such as NPT or G.\u003cbr\u003e\n                This union design allows the valve body to be installed or removed more easily for maintenance or replacement, without cutting the pipe or rotating the valve body itself.\u003cbr\u003e\n                The pipe sockets are made to a \u003cstrong\u003e\u003cu\u003eUS standard\u003c\/u\u003e\u003c\/strong\u003e. Please note that the Socket Inside Diameter (I.D.) may vary by national standard even for the same nominal size, such as 1-1\/4\". For other connection standards, including British Standard, Japanese Industrial Standard, or others, please contact our customer service team.\n            \u003c\/p\u003e\n        \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cp class=\"faq\"\u003e\u003cb\u003eProblem 2: What precautions apply to auto-return models?\u003c\/b\u003e\u003c\/p\u003e\n    \u003cp class=\"section-description\"\u003e\n        The auto-return ball valve requires a minimum power-on duration of 60 seconds (≥60s). This step is mandatory during first commissioning or after a prolonged power cut to ensure reliable auto-reset performance. Before using the manual override, always disconnect the power first. For auto-return models, please wait for a short period after power is disconnected before manual operation, as the actuator needs time to discharge; otherwise, the valve may be difficult to turn manually.\n    \u003c\/p\u003e\n\n    \u003cp class=\"faq\"\u003e\u003cb\u003eProblem 3: Does this model come with a manual function?\u003c\/b\u003e\u003c\/p\u003e\n    \u003cp class=\"section-description\"\u003e\n        \u003cstrong\u003eYes.\u003c\/strong\u003e The manual override function allows you to control the opening and closing of the valve during a power outage. A hexagonal wrench is included with the valve for this purpose.\n    \u003c\/p\u003e\n\n    \u003cp class=\"faq\"\u003e\u003cb\u003eProblem 4: What should be noted during manual operation?\u003c\/b\u003e\u003c\/p\u003e\n    \u003cp class=\"section-description\"\u003e\n        Power must be disconnected before manual operation. Turn the valve according to the \"O\" and \"S\" indicators: \"O\" = Open, \"S\" = Close. The valve should be turned fully open or fully closed; do not leave it in a middle position, as this may damage the valve. For auto-return models, wait for a short period after disconnecting power before manual operation.\n    \u003c\/p\u003e\n\n    \u003cp class=\"faq\"\u003e\u003cb\u003eProblem 5: How to read the indicator window?\u003c\/b\u003e\u003c\/p\u003e\n    \u003cp class=\"section-description\"\u003e\n        The external arrow shows the valve position. When the arrow points to \"0\", the valve is fully closed; when it points to \"90\", the valve is fully open.\n    \u003c\/p\u003e\n\n    \u003cp class=\"faq\"\u003e\u003cb\u003eProblem 6: What is a Union connection?\u003c\/b\u003e\u003c\/p\u003e\n    \u003cp class=\"section-description\"\u003e\n        A Union connection is a detachable valve structure that allows the valve body to be removed more easily for maintenance or replacement without cutting the pipe. On this product, the pipe connection ends are Socket End ports designed for solvent cement bonding.\n    \u003c\/p\u003e\n\n    \u003cp class=\"faq\"\u003e\u003cb\u003eProblem 7: What should be noted about the four main control methods?\u003c\/b\u003e\u003c\/p\u003e\n    \u003cp class=\"section-description\"\u003e\n        Please pay attention to the wiring type when purchasing. Only auto-return models will automatically return to the closed position when power is lost. Other control methods do not automatically reset after power loss and will remain in their current position.\n    \u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/body\u003e","brand":"U.S. Solid","offers":[{"title":"Default Title","offer_id":47294841422079,"sku":"JFMSV00468","price":180.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/2_9c8be148-836c-4030-8810-599b2b24aea6.jpg?v=1758694502"},{"product_id":"2-double-union-upvc-motorized-ball-valve-dc-24v-2-wire-auto-return-normally-closed-with-manual-override-epdm-seal","title":"2\" Double Union UPVC Motorized Ball Valve - DC 24V, 2-Wire Auto Return, Normally Closed with Manual Override \u0026 EPDM Seal","description":"\u003cbody\u003e\n    \u003cmeta charset=\"UTF-8\"\u003e\n    \u003cmeta name=\"viewport\" content=\"width=device-width, initial-scale=1.0\"\u003e\n    \u003ctitle\u003eResponsive Page with Multiple Modules\u003c\/title\u003e\n    \u003cstyle\u003e\n\n        .desktop-img {\n            display: block;\n        }\n        .mobile-img {\n            display: none;\n        }\n\n        .section-title {\n            font-size: 22px;\n            line-height: 22px;\n            font-weight: bold;\n            margin: 15px 0 5px;\n            font-family: Arial;\n        }\n\n        .section-title2 {\n            font-size: 22px;\n            line-height: 22px;\n            font-weight: bold;\n            margin: 15px 0 3px;\n            font-family: Arial;\n        }\n\n        .section-title3 {\n            font-size: 22px;\n            line-height: 22px;\n            font-weight: bold;\n            margin: 15px 0 10px;\n            font-family: Arial;\n        }\n\n        .section-description {\n            font-size: 16px;\n            line-height: 26px;\n            margin-top: 0px;\n            margin-bottom: 5px;\n            font-family: Arial;\n        }\n\n        .faq {\n            font-size: 16px;\n            margin: 0;\n            line-height: 26px;\n            background-color: #f2f2f2;\n            padding: 5px;\n        }\n\n        .section-description2 {\n            font-size: 16px;\n            line-height: 26px;\n            margin: 0px;\n            font-family: Arial;\n        }\n\n        .parameters-table-wrapper {\n            overflow-x: auto;\n            -webkit-overflow-scrolling: touch;\n            margin-top: 0px;\n        }\n\n        .parameters-table {\n            width: 100%;\n            min-width: 1000px;\n            border-collapse: collapse;\n            margin-top: 0px;\n        }\n\n        .parameters-table th, .parameters-table td {\n            border-top: 1.2px solid #a6a6a6;\n            border-bottom: 1.2px solid #a6a6a6;\n            border-left: none;\n            border-right: none;\n            padding: 5px 2px;\n            text-align: left;\n            font-size: 16px;\n            line-height: 16px;\n        }\n\n        .parameters-table th {\n            background-color: #f2f2f2;\n            color: #2c2c2c;\n            font-weight: bold;\n        }\n\n        .parameters-table .bg-gray {\n            background-color: #f2f2f2;\n        }\n\n        .options-table-wrapper {\n            overflow-x: auto;\n            -webkit-overflow-scrolling: touch;\n            margin-top: 0px;\n        }\n\n        .options-table {\n            width: 100%;\n            min-width: 1000px;\n            border-collapse: collapse;\n            margin-top: 0px;\n            box-shadow: 0 6px 25px rgba(0, 0, 0, 0.1);\n        }\n\n        .options-table th, .options-table td {\n            border: 2px solid #000;\n            padding: 5px 2px;\n            text-align: center;\n            font-size: 16px;\n            line-height: 16px;\n        }\n\n        .options-table th {\n            background-color: #f2f2f2;\n            color: #2c2c2c;\n            font-weight: bold;\n        }\n\n        .parameters-table2 {\n            width: 100%;\n            min-width: 1000px;\n            border-collapse: collapse;\n            margin-top: 0px;\n        }\n\n        .parameters-table2 th, .parameters-table2 td {\n            border-top: 1.2px solid #a6a6a6;\n            border-bottom: 1.2px solid #a6a6a6;\n            border-left: none;\n            border-right: none;\n            padding: 5px 2px;\n            text-align: center;\n            font-size: 16px;\n            line-height: 16px;\n        }\n\n        .parameters-table2 th {\n            background-color: #f2f2f2;\n            color: #2c2c2c;\n            font-weight: bold;\n        }\n\n        .parameters-table2 .bg-gray {\n            background-color: #f2f2f2;\n        }\n\n        .options-table-wrapper2 {\n            overflow-x: auto;\n            -webkit-overflow-scrolling: touch;\n            margin-top: 0px;\n        }\n\n        .instruction-container {\n            display: flex;\n            justify-content: space-between;\n            align-items: flex-start;\n            gap: 10px;\n            margin-bottom: 0px;\n        }\n\n        .img-container {\n            width: 35%;\n            display: flex;\n            justify-content: center;\n        }\n\n        .text-container {\n            width: 65%;\n            font-size: 16px;\n            font-family: Arial;\n        }\n\n        .instruction-container2 {\n            display: flex;\n            justify-content: space-between;\n            align-items: flex-start;\n            gap: 10px;\n            margin-bottom: 0px;\n        }\n\n        .img-container2 {\n            width: 50%;\n            display: flex;\n            justify-content: center;\n        }\n\n        .text-container2 {\n            width: 50%;\n            display: flex;\n            justify-content: center;\n        }\n\n        @media (max-width: 768px) {\n            .parameters-table th, .parameters-table td {\n                font-size: 14px;\n                padding: 8px 4px;\n            }\n\n            .options-table th, .options-table td {\n                font-size: 14px;\n                padding: 8px 4px;\n            }\n\n            .parameters-table-wrapper {\n                overflow-x: auto;\n            }\n\n            .parameters-table2 th, .parameters-table2 td {\n                font-size: 14px;\n                padding: 8px 4px;\n            }\n\n            .parameters-table-wrapper2 {\n                overflow-x: auto;\n            }\n\n            .desktop-img {\n                display: none;\n            }\n\n            .mobile-img {\n                display: block;\n            }\n\n            .instruction-container {\n                flex-direction: column;\n                align-items: center;\n            }\n\n            .img-container, .text-container {\n                width: 100%;\n                margin-bottom: 0px;\n            }\n\n            .instruction-container2 {\n                flex-direction: column;\n                align-items: center;\n            }\n\n            .img-container2, .text-container2 {\n                width: 100%;\n                margin-bottom: 0px;\n            }\n        }\n\n        @media (max-width: 480px) {\n            .parameters-table th, .parameters-table td {\n                font-size: 12px;\n                padding: 6px 3px;\n            }\n\n            .options-table th, .options-table td {\n                font-size: 12px;\n            }\n\n            .parameters-table-wrapper {\n                overflow-x: auto;\n            }\n\n            .parameters-table2 th, .parameters-table2 td {\n                font-size: 12px;\n                padding: 6px 3px;\n            }\n\n            .parameters-table-wrapper2 {\n                overflow-x: auto;\n            }\n\n            .desktop-img {\n                display: none;\n            }\n\n            .mobile-img {\n                display: block;\n            }\n\n            .instruction-container {\n                flex-direction: column;\n            }\n\n            .instruction-container2 {\n                flex-direction: column;\n            }\n        }\n\n    \u003c\/style\u003e\n\n\u003c!-- Background --\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/UPVC2\/b.jpg\" class=\"desktop-img\" alt=\"Desktop Image 1\"\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/UPVC2\/b-p.jpg\" class=\"mobile-img\" alt=\"Mobile Image 1\"\u003e\n\u003c!-- Introduction - 2-Wire Auto Return \/ Standard --\u003e\n\u003cdiv\u003e\n    \u003ch2 class=\"section-title\"\u003eIntroduction\u003c\/h2\u003e\n    \u003cp class=\"section-description\"\u003e\n        Our electric UPVC ball valve series has been upgraded to include three larger sizes: 1-1\/4\", 1-1\/2\", and 2\". These larger valves feature a unique \u003cstrong\u003e\u003cu\u003eUS standard socket end \u0026amp; double union connection\u003c\/u\u003e\u003c\/strong\u003e—enabling exceptional ease of installation and maintenance with a simple solvent cement bond, \u003cstrong\u003e\u003cu\u003eunlike\u003c\/u\u003e\u003c\/strong\u003e threaded NPT or G connections. For other connection standards, please contact our customer service.\u003cbr\u003eThese valves are \u003cstrong\u003e\u003cu\u003e2-wire auto return\u003c\/u\u003e\u003c\/strong\u003e and remain in a normally-closed position. They automatically close if power is lost. A manual override is also included for use during power outages. All valves have EPDM seals for reliable performance.\n    \u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- Applications--\u003e\n     \u003ch2 class=\"section-title2\"\u003eApplications\u003c\/h2\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/UPVC2\/a.jpg\" class=\"desktop-img\" alt=\"Desktop Image 1\"\u003e\n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/UPVC2\/a-p.jpg\" class=\"mobile-img\" alt=\"Desktop Image 2\"\u003e\n\u003c!-- Features - 2-Wire Auto Return --\u003e\n\u003cdiv\u003e\n    \u003ch2 class=\"section-title\"\u003eFeatures\u003c\/h2\u003e\n    \u003cul class=\"section-description2\"\u003e\n        \u003cli\u003e\n\u003cstrong\u003eUnion \u0026amp; Socket End:\u003c\/strong\u003e Different from standard NPT\/G threaded connections, it uses socket-gluing for sealing and integrates threaded structures, balancing connection stability with quick disassembly and maintenance needs.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eManual Function:\u003c\/strong\u003e Comes with a hex wrench as standard; allows manual valve opening and closing during power outages. \"O\"=Open, \"S\"=Close.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eIndicator Window:\u003c\/strong\u003e Built-in engraved marks directly show the valve's open\/closed status. External arrow pointing to \"0\" means fully closed; pointing to \"90\" means fully open.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003ePremium Material:\u003c\/strong\u003e Valve body made of UPVC with EPDM seals, meeting general operating requirements.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003e2-Wire Auto Return:\u003c\/strong\u003e Uses a 2-wire auto-return configuration. The valve remains normally closed and automatically closes when power is lost, making it suitable for fail-safe applications.\u003c\/li\u003e\n    \u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/UPVC2\/2-Return.jpg\" class=\"desktop-img\" alt=\"Desktop Image 1\"\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/UPVC2\/2-Return-p.jpg\" class=\"mobile-img\" alt=\"Desktop Image 2\"\u003e\n\u003c!-- User Manual --\u003e\n\u003cdiv\u003e\n    \u003ch2 class=\"section-title\"\u003eUser Manual\u003c\/h2\u003e\n    \u003cp class=\"section-description\"\u003e\n        To learn how to use this product, please refer to the \u003ca href=\"https:\/\/file.ussolid.com\/content\/JFMSV\/Manual-%20USS-UPVC.pdf\" target=\"_blank\"\u003euser manual\u003c\/a\u003e.\n    \u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- Technical Data --\u003e\n    \u003ch2 class=\"section-title3\"\u003eTechnical Data\u003c\/h2\u003e \n    \u003cdiv class=\"parameters-table-wrapper\"\u003e\n        \u003ctable class=\"parameters-table\"\u003e\n            \u003ctbody\u003e \n                \u003ctr\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003ePort Size\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003e2\"\u003c\/td\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003eUSS-MSV469\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003ePort\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003e2 Way\u003c\/td\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eThread\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003eNo Thread\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eConnection\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003eUnion \u0026amp; Socket End\u003c\/td\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eMax Power\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003e36W\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eSocket Inside Diameter\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003e60.3mm (US Standard)\u003c\/td\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eWith Hex Wrench\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003eYes\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eWiring\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003e2-Wire Auto Return\u003c\/td\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eManual Function\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003eYes\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eSignal feedback function\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003eNo\u003c\/td\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eIndicator Window\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003eYes\u003c\/td\u003e\n                \u003c\/tr\u003e\n\n                \u003ctr\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eBody Material\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003eUPVC\u003c\/td\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eNormal Position\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003eNormally Closed\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eSeal Material\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003eEPDM\u003c\/td\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eTemp Range (Medium)\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003e33.8℉ to 104℉\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eWorking Voltage\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003eDC 24V\u003c\/td\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eClose\/Open Time\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003e10-12s\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eMax Torque\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003e20 N·m\u003c\/td\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eMax. Pressure\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003e232 psi\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eLife Expectancy\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003e20,000 Cycles\u003c\/td\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eIP Rating\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003eIP65\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003ePackage Size\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003e9.8\"x8.7\"x5.9\"\u003c\/td\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eGross Weight\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003e5.51 lb\u003c\/td\u003e\n                \u003c\/tr\u003e \n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n    \u003cp class=\"section-description\"\u003e*To view the full table on mobile, please swipe left or right on the screen.\u003c\/p\u003e\n\u003c!-- Wiring - 2-Wire Auto Return --\u003e\n\u003ch2 class=\"section-title\"\u003e2-Wire Auto Return\u003c\/h2\u003e\n\u003cdiv class=\"instruction-container\"\u003e\n    \u003cdiv class=\"img-container\"\u003e\n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Wire\/return.jpg\" alt=\"\" style=\"width: 100%; height: auto;\"\u003e\n    \u003c\/div\u003e\n    \u003cdiv class=\"text-container\"\u003e\n        \u003cp class=\"section-description\"\u003e\n            This model uses a 2-wire auto-return wiring method. It is normally closed by default: the valve opens when powered and automatically returns to the closed position when power is lost or disconnected.\n        \u003c\/p\u003e\n        \u003cul class=\"section-description2\"\u003e\n            \u003cli\u003eFor the basic version without signal feedback, simply ignore the signal wire connections shown in the diagram.\u003c\/li\u003e\n            \u003cli\u003eWire Color Coding: BK (Black), RD (Red), YW (Yellow), WT (White), BU (Blue), GN (Green), and OG (Orange).\u003c\/li\u003e\n            \u003cli\u003eFor reliable auto-reset performance, power the valve for at least 60 seconds (≥60s) during first commissioning or after a prolonged power cut.\u003c\/li\u003e\n            \u003cli\u003eBefore manual operation, disconnect power and wait briefly for the actuator to discharge.\u003c\/li\u003e\n        \u003c\/ul\u003e\n    \u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- FAQ --\u003e\n\u003cdiv\u003e\n    \u003ch2 class=\"section-title\"\u003eFAQ\u003c\/h2\u003e\n    \u003cp class=\"faq\"\u003e\u003cb\u003eProblem 1: What is unique about the connection method of this ball valve?\u003c\/b\u003e\u003c\/p\u003e\n    \u003cdiv class=\"instruction-container\"\u003e\n        \u003cdiv class=\"img-container\"\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/UPVC2\/size-2.jpg\" alt=\"\" style=\"width: 100%; height: auto;\"\u003e\n        \u003c\/div\u003e\n        \u003cdiv class=\"text-container\"\u003e\n            \u003cp class=\"section-description\"\u003e\n                The larger sizes of our ball valve series (1-1\/4\", 1-1\/2\", and 2\") come standard with \u003cstrong\u003e\u003cu\u003eSocket End ports\u003c\/u\u003e\u003c\/strong\u003e for solvent cement bonding and a \u003cstrong\u003e\u003cu\u003eUnion structure\u003c\/u\u003e\u003c\/strong\u003e for easier installation and maintenance, instead of common threaded connections such as NPT or G.\u003cbr\u003e\n                This union design allows the valve body to be installed or removed more easily for maintenance or replacement, without cutting the pipe or rotating the valve body itself.\u003cbr\u003e\n                The pipe sockets are made to a \u003cstrong\u003e\u003cu\u003eUS standard\u003c\/u\u003e\u003c\/strong\u003e. Please note that the Socket Inside Diameter (I.D.) may vary by national standard even for the same nominal size, such as 1-1\/4\". For other connection standards, including British Standard, Japanese Industrial Standard, or others, please contact our customer service team.\n            \u003c\/p\u003e\n        \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cp class=\"faq\"\u003e\u003cb\u003eProblem 2: What precautions apply to auto-return models?\u003c\/b\u003e\u003c\/p\u003e\n    \u003cp class=\"section-description\"\u003e\n        The auto-return ball valve requires a minimum power-on duration of 60 seconds (≥60s). This step is mandatory during first commissioning or after a prolonged power cut to ensure reliable auto-reset performance. Before using the manual override, always disconnect the power first. For auto-return models, please wait for a short period after power is disconnected before manual operation, as the actuator needs time to discharge; otherwise, the valve may be difficult to turn manually.\n    \u003c\/p\u003e\n\n    \u003cp class=\"faq\"\u003e\u003cb\u003eProblem 3: Does this model come with a manual function?\u003c\/b\u003e\u003c\/p\u003e\n    \u003cp class=\"section-description\"\u003e\n        \u003cstrong\u003eYes.\u003c\/strong\u003e The manual override function allows you to control the opening and closing of the valve during a power outage. A hexagonal wrench is included with the valve for this purpose.\n    \u003c\/p\u003e\n\n    \u003cp class=\"faq\"\u003e\u003cb\u003eProblem 4: What should be noted during manual operation?\u003c\/b\u003e\u003c\/p\u003e\n    \u003cp class=\"section-description\"\u003e\n        Power must be disconnected before manual operation. Turn the valve according to the \"O\" and \"S\" indicators: \"O\" = Open, \"S\" = Close. The valve should be turned fully open or fully closed; do not leave it in a middle position, as this may damage the valve. For auto-return models, wait for a short period after disconnecting power before manual operation.\n    \u003c\/p\u003e\n\n    \u003cp class=\"faq\"\u003e\u003cb\u003eProblem 5: How to read the indicator window?\u003c\/b\u003e\u003c\/p\u003e\n    \u003cp class=\"section-description\"\u003e\n        The external arrow shows the valve position. When the arrow points to \"0\", the valve is fully closed; when it points to \"90\", the valve is fully open.\n    \u003c\/p\u003e\n\n    \u003cp class=\"faq\"\u003e\u003cb\u003eProblem 6: What is a Union connection?\u003c\/b\u003e\u003c\/p\u003e\n    \u003cp class=\"section-description\"\u003e\n        A Union connection is a detachable valve structure that allows the valve body to be removed more easily for maintenance or replacement without cutting the pipe. On this product, the pipe connection ends are Socket End ports designed for solvent cement bonding.\n    \u003c\/p\u003e\n\n    \u003cp class=\"faq\"\u003e\u003cb\u003eProblem 7: What should be noted about the four main control methods?\u003c\/b\u003e\u003c\/p\u003e\n    \u003cp class=\"section-description\"\u003e\n        Please pay attention to the wiring type when purchasing. Only auto-return models will automatically return to the closed position when power is lost. Other control methods do not automatically reset after power loss and will remain in their current position.\n    \u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/body\u003e","brand":"U.S. Solid","offers":[{"title":"Default Title","offer_id":47294841880831,"sku":"JFMSV00469","price":181.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/3_c2e2f334-14b7-4e14-892b-83f625b659fa.jpg?v=1758694547"},{"product_id":"20-pack-1-2-upvc-motorized-ball-valve-9-36v-ac-dc-plastic-electrical-ball-valve-with-full-port-2-wire-auto-return-normally-closed","title":"20-Pack 1\/2\" UPVC Motorized Ball Valve - 9-36V AC\/DC Plastic Electrical Ball Valve with Full Port, 2 Wire Auto Return, Normally Closed","description":"\u003cbody\u003e \n\n\n    \u003cstyle\u003e\n        @media only screen and (max-width: 600px) {\n        }\n    \u003c\/style\u003e\n\n\n    \u003cdiv class=\"desktop-only\"\u003e\n        \n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; line-height: 26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 10px; color: black; font-family: Arial;\"\u003eMotorized ball valves are a vital piece of equipment in numerous applications. This model opens and closes in 6-8 seconds, and remains in its new position while expending almost no energy. This is a key difference between motorized ball valves and many solenoid valves. Most solenoid valves are energized continuously when in a new position, while motorized ball valves expend energy only when changing from open to close, or vice versa.\u003cbr\u003eThe 2 wire auto return model is perfect for situations where the valve needs to be closed in case of power loss. The valve can be energized to open, and left hooked up, with negligible energy used once fully opened. To close, simply shutoff power to the valve. This valve is convenient because it can be operated with a simple on off switch. When on, it will remain open, when turned off (or power is lost for some other reason) the valve automatically closes.\u003c\/p\u003e\n        \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/1.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n             \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n    \u003ctable style=\"border-collapse: collapse;\n                  border: 0px;\n                  width: 100%;\n                  font-family: Arial;\n                  overflow-x: auto;\n                  background-color: #FFFFFF;\"\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"width: 100%;text-align: left;\n                       padding: 0px;\n                       font-size: 16px;\n                       border: 0;\n                       background-color: #FFFFFF;\"\u003e\n                \u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 1\/2\" style=\"width: 100%;height: 100%;\"\u003e\n            \u003c\/td\u003e\n            \u003ctd style=\"width: 100%;text-align: left;\n                       padding: 0px;\n                       font-size: 16px;\n                       border: 0;\n                       background-color: #FFFFFF;\"\u003e\n                \u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 1\/2\" style=\"width: 100%;height: 100%;\"\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/table\u003e\n\u003c\/div\u003e\n          \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e \n \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV00091\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eU.S. Solid\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1\/2\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e2 Wire Auto Return\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eUPVC\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e6 - 8 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e9-36V AC\/DC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e5 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e2 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1°C to 55°C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e50,000 to 80,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eFull\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\/G\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNormally Closed\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1°C to 50°C\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eIP65\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/CE\/CE-EMC.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP65 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYES. The motorized ball valve is made of lead-free UPVC.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n    \u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP65 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP65. The first digit 6 indicates complete dust - tightness. The second digit 5 means protection against water jets from any direction. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/valve%20model.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAT MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/JFMSV-User-manual.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n    \u003c\/div\u003e\n    \u003cdiv class=\"mobile-only\"\u003e\n        \n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; line-height:26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 0px; color: black; font-family: Arial;\"\u003eMotorized ball valves are a vital piece of equipment in numerous applications. This model opens and closes in 6-8 seconds, and remains in its new position while expending almost no energy. This is a key difference between motorized ball valves and many solenoid valves. Most solenoid valves are energized continuously when in a new position, while motorized ball valves expend energy only when changing from open to close, or vice versa.\u003cbr\u003eThe 2 wire auto return model is perfect for situations where the valve needs to be closed in case of power loss. The valve can be energized to open, and left hooked up, with negligible energy used once fully opened. To close, simply shutoff power to the valve. This valve is convenient because it can be operated with a simple on off switch. When on, it will remain open, when turned off (or power is lost for some other reason) the valve automatically closes.\u003c\/p\u003e\n            \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/1.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-bottom:10px; margin-top:20px; color: black;\"\u003e\u003cstrong\u003eAPPLICATION\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n    \u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 1\/2\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n    \u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 1\/2\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n\u003c\/div\u003e\n      \u003cp style=\"font-size: 16px; text-align: left; margin-bottom:10px; margin-top:20px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV00091\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eU.S. Solid\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1\/2\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e2 Wire Auto Return\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eUPVC\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e6 - 8 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e9-36V AC\/DC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e5 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e2 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1°C to 55°C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e50,000 to 80,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eFull\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\/G\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNormally Closed\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1°C to 50°C\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eIP65\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/CE\/CE-EMC.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP65 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYES. The motorized ball valve is made of lead-free UPVC.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n    \u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP65 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP65. The first digit 6 indicates complete dust - tightness. The second digit 5 means protection against water jets from any direction. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/valve%20model.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAT MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material-APP.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/JFMSV-User-manual.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n    \u003cscript\u003e\n\n        \n        const isMobile = window.matchMedia(\"only screen and (max-width: 600px)\").matches;\n        const desktopContent = document.querySelector('.desktop-only');\n        const mobileContent = document.querySelector('.mobile-only');\n\n        if (isMobile) {\n            \n            console.log('');\n           \n            desktopContent.style.display = 'none';\n            mobileContent.style.display = 'block';\n        } else {\n           \n            console.log('');            \n            \n            desktopContent.style.display = 'block';\n            mobileContent.style.display = 'none';\n        }\n    \u003c\/script\u003e\n\n\n\n\u003c\/body\u003e","brand":"U.S. Solid","offers":[{"title":"Default Title","offer_id":47601243554047,"sku":"JFMSV00091-CP20","price":677.09,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/1__04005.1697099836.1280.1280.jpg?v=1731291530"},{"product_id":"1-1-4-upvc-motorized-ball-valve-full-port-9-24v-ac-dc-2-wire-auto-return-ip67-normally-closed-with-manual-reset","title":"1-1\/4\" UPVC Motorized Ball Valve, Full Port, 9–24V AC\/DC, 2-Wire Auto Return, IP67, Normally Closed with Manual Reset","description":"\u003cmeta charset=\"UTF-8\"\u003e\n\u003cmeta name=\"viewport\" content=\"width=device-width, initial-scale=1.0\"\u003e\n\n\u003cstyle\u003e\n.desktop-img { display: block; width: 100%; }\n.mobile-img { display: none; width: 100%; }\n\n.section-title,\n.section-title2,\n.section-title3,\n.section-title4 {\n    font-size: 22px;\n    line-height: 22px;\n    font-weight: bold;\n    margin: 15px 0 10px;\n    font-family: Arial;\n    color: black;\n}\n\n.title-center {\n    text-align: center;\n}\n\n.section-description {\n    font-size: 16px;\n    line-height: 26px;\n    margin: 5px 0;\n    font-family: Arial;\n    color: black;\n}\n\n.section-description2 {\n    font-size: 16px;\n    line-height: 26px;\n    margin: 0;\n    font-family: Arial;\n}\n\n.faq {\n    font-size: 16px;\n    line-height: 26px;\n    padding: 5px;\n    margin: 10px 0 5px;\n    font-family: Arial;\n    color: black;\n}\n\n.warning-title {\n    font-size: 22px;\n    text-align: left;\n    margin-top: 20px;\n    margin-bottom: 10px;\n    line-height: 26px;\n    color: black;\n    font-weight: bold;\n    font-family: Arial;\n  }\n\n  .flex-row {\n    display: flex;\n    gap: 20px;\n    margin: 20px 0;\n}\n\n.flex-item {\n    flex: 1;\n    min-width: 0;\n}\n\n.flex-item img {\n    width: 100%;\n    display: block;\n}\n\n.parameters-table-wrapper {\n    overflow-x: auto;\n    -webkit-overflow-scrolling: touch;\n}\n\n.parameters-table {\n    width: 100%;\n    min-width: 1000px;\n    border-collapse: collapse;\n    font-family: Arial;\n}\n\n.parameters-table th,\n.parameters-table td {\n    border-top: 1.2px solid #a6a6a6;\n    border-bottom: 1.2px solid #a6a6a6;\n    padding: 5px 2px;\n    text-align: left;\n    font-size: 16px;\n}\n\n.parameters-table th,\n.parameters-table .bg-gray {\n    background-color: #f2f2f2;\n    font-weight: bold;\n}\n\n.bg-gray {\n    color: black;\n    font-weight: bold;\n}\n\n@media (max-width: 768px) {\n    .desktop-img { display: none; }\n    .mobile-img { display: block; }\n    .flex-row {\n        flex-direction: column;\n        gap: 10px;\n    }\n    .parameters-table th,\n    .parameters-table td {\n        font-size: 14px;\n    }\n}\n\n@media (max-width: 480px) {\n    .parameters-table th,\n    .parameters-table td {\n        font-size: 12px;\n    }\n}\n\u003c\/style\u003e\n\n\u003c!-- Cover Image --\u003e\n\u003cp\u003e\n  \u003cimg class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" alt=\"\"\u003e\n  \u003cimg class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" alt=\"\"\u003e\n\u003c\/p\u003e\n\n\u003c!-- INTRODUCTION --\u003e\n\u003ch2 class=\"section-title\"\u003eINTRODUCTION\u003c\/h2\u003e\n\u003cp class=\"section-description\"\u003e\nMotorized ball valves are a vital piece of equipment in numerous applications. This model opens and closes in 3-5 seconds, and remains in its new position while expending almost no energy. This is a key difference between motorized ball valves and many solenoid valves. Most solenoid valves are energized continuously when in a new position, while motorized ball valves expend energy only when changing from open to close, or vice versa.\n\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\nThe 2 wire auto return model is perfect for situations where the valve needs to be closed in case of power loss. The valve can be energized to open, and left hooked up, with negligible energy used once fully opened. To close, simply shutoff power to the valve. This valve is convenient because it can be operated with a simple on off switch. When on, it will remain open, when turned off (or power is lost for some other reason) the valve automatically closes.\n\u003c\/p\u003e\n\n\u003c!-- FEATURES --\u003e\n\u003ch2 class=\"section-title\"\u003eFEATURES\u003c\/h2\u003e\n\u003cp\u003e\n  \u003cimg class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/1.png\" alt=\"\"\u003e\n  \u003cimg class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/1.png\" alt=\"\"\u003e\n\u003c\/p\u003e\n\n\u003c!-- MORE DETAILS --\u003e\n\u003ch2 class=\"section-title3\"\u003eMORE DETAILS\u003c\/h2\u003e\n\u003cdiv class=\"flex-row\"\u003e\n    \n    \u003cdiv class=\"flex-item\"\u003e\n        \u003ch2 class=\"section-title4 title-center\"\u003eMANUAL OVERRIDE\u003c\/h2\u003e\n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/jfesm50020-more1.png\" alt=\"GIF 1\"\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"flex-item\"\u003e\n        \u003ch2 class=\"section-title4 title-center\"\u003eDETACHABLE DESIGN\u003c\/h2\u003e\n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/jfesm50020-more2.jpg\" alt=\"GIF 2\"\u003e\n    \u003c\/div\u003e\n\n\u003c\/div\u003e\n\n\u003c!-- APPLICATIONS --\u003e\n\u003ch2 class=\"section-title2\"\u003eAPPLICATIONS\u003c\/h2\u003e\n\u003cp\u003e\n  \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" alt=\"\"\u003e\n\u003c\/p\u003e\n\n\u003c!-- OPERATION PERFORMANCE --\u003e\n\u003ch2 class=\"section-title3\"\u003eOPERATION PERFORMANCE\u003c\/h2\u003e\n\u003cdiv class=\"flex-row\"\u003e\n    \n    \u003cdiv class=\"flex-item\"\u003e\n        \u003ch2 class=\"section-title4 title-center\"\u003eAFTER WIRING\u003c\/h2\u003e\n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 1\"\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"flex-item\"\u003e\n        \u003ch2 class=\"section-title4 title-center\"\u003eDISCONNECT THE WIRING\u003c\/h2\u003e\n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 2\"\u003e\n    \u003c\/div\u003e\n\n\u003c\/div\u003e\n\n\u003c!-- SPECIFICATIONS --\u003e\n\u003ch2 class=\"section-title3\"\u003eSPECIFICATIONS\u003c\/h2\u003e\n\u003cdiv class=\"parameters-table-wrapper\"\u003e\n\u003ctable class=\"parameters-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003eModel\u003c\/td\u003e\n\u003ctd\u003eUSS-MSV50020 \/ USS-MSV50020-G\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eU.S. Solid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003eSize\u003c\/td\u003e\n\u003ctd\u003e1-1\/4\"\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003eWiring Type\u003c\/td\u003e\n\u003ctd\u003e2 Wire Auto Return\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003eValve Material\u003c\/td\u003e\n\u003ctd\u003eUPVC\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003eEnclosure Rating\u003c\/td\u003e\n\u003ctd\u003eIP67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003eOperating Time\u003c\/td\u003e\n\u003ctd\u003e≤12 Seconds\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003eWorking Voltage\u003c\/td\u003e\n\u003ctd\u003e9 - 24V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003eMax Power\u003c\/td\u003e\n\u003ctd\u003e36 W\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003eMax Torque\u003c\/td\u003e\n\u003ctd\u003e15 N m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003eMax Medium Pressure\u003c\/td\u003e\n\u003ctd\u003e1.0 Mpa\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003eTemperature Range for Flow Medium\u003c\/td\u003e\n\u003ctd\u003e2°C to 55°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003eLife Expectancy\u003c\/td\u003e\n\u003ctd\u003e70,000 Cycles\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003eBore Type\u003c\/td\u003e\n\u003ctd\u003eFull\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003eThread Type\u003c\/td\u003e\n\u003ctd\u003eNPT\/G\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003eOperating State\u003c\/td\u003e\n\u003ctd\u003eNormally Closed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003eAmbient Temperature Range\u003c\/td\u003e\n\u003ctd\u003e-15°C to 50°C\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003eBall Seal\u003c\/td\u003e\n\u003ctd\u003ePTFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp class=\"section-description\"\u003e*To view the full table on mobile, please swipe left or right on the screen.\u003c\/p\u003e\n\n\u003c!-- CE CERTIFIED QUALITY \u0026 SAFETY --\u003e\n\u003ch2 class=\"section-title3\"\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/h2\u003e\n\u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/CE\/CE.jpg\"\u003e\n\u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/CE\/CE.jpg\"\u003e\n\n\u003c!-- FAQ --\u003e\n\u003ch2 class=\"section-title\"\u003eFAQ\u003c\/h2\u003e\n\n\u003cp class=\"faq\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\nThe motor's housing is rated at IP67 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\n\u003c\/p\u003e\n\n\u003cp class=\"faq\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\nIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\n\u003c\/p\u003e\n\n\u003cp class=\"faq\"\u003e\u003cb\u003e3. What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\nIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\n\u003c\/p\u003e\n\n\u003cp class=\"faq\"\u003e\u003cb\u003e4. Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\nYES. The motorized ball valve is made of lead-free Polyvinyl Chloride and is NSF certified.\n\u003c\/p\u003e\n\n\u003cp class=\"faq\"\u003e\u003cb\u003e5. For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\nTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\n\u003c\/p\u003e\n\n\u003cp class=\"faq\"\u003e\u003cb\u003e6. Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\nYes, our motorized ball valves are suitable for use with propane.\n\u003c\/p\u003e\n\n\u003c!-- WARNING --\u003e\n\u003ch2 class=\"section-title\"\u003eWARNING\u003c\/h2\u003e\n\n\u003cp class=\"section-description\"\u003e\n\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\n\u003c\/p\u003e\n\n\u003cp class=\"section-description\"\u003e\n\u003cb\u003e2.\u003c\/b\u003e The valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\n\u003c\/p\u003e\n\n\u003cp class=\"section-description\"\u003e\n\u003cb\u003e3.\u003c\/b\u003e Only Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\n\u003c\/p\u003e\n\n\u003cp class=\"section-description\"\u003e\n\u003cb\u003e4.\u003c\/b\u003e While the motorized ball valves have an IP67 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\n\u003c\/p\u003e\n\n\u003cp class=\"section-description\"\u003e\n\u003cb\u003e5.\u003c\/b\u003e These valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\n\u003c\/p\u003e\n\n\u003c!-- Valve Attributes --\u003e\n\u003ch2 class=\"section-title\"\u003eValve Attributes\u003c\/h2\u003e\n\n\u003cp class=\"section-description\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\nNormally Closed: The valve is closed when power is off and opens when power is on.\n\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\nNormally Open: The valve is open when power is off and closes when power is on.\n\u003c\/p\u003e\n\n\u003cp class=\"section-description\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\nFull Port: It has a wide internal passage, resulting in low water - flow resistance.\n\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\nStandard Port: Meets regular usage requirements.\n\u003c\/p\u003e\n\n\u003cp class=\"section-description\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\nThe valves have an ingress - protection rating of IP67. The 6 in IP67 represents complete dust - tightness. The 7 in IP67 indicates protection against water immersion up to 1 meter for 30 minutes. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\n\u003c\/p\u003e\n\u003cp\u003e\n  \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/IP67-UPVC.png\" alt=\"\"\u003e\n\u003c\/p\u003e\n\n\u003c!-- Valve Attributes --\u003e\n\u003ch2 class=\"section-title\"\u003eWIRING SCHEMATICS\u003c\/h2\u003e\n\u003cp\u003e\n  \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" alt=\"\"\u003e\n\u003c\/p\u003e\n\n\u003cp class=\"section-description\"\u003e\n\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\n\u003c\/p\u003e\n\n\u003c!-- CHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS --\u003e\n\u003ch2 class=\"section-title3\"\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS \u0026amp; SAFETY\u003c\/h2\u003e\n\u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material.png\"\u003e\n\u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material-APP.png\"\u003e\n\n\u003cp class=\"section-description\"\u003e\nDownload user manual\n\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/Manual-50020-28.pdf\" target=\"_blank\"\u003ehere\u003c\/a\u003e.\n\u003c\/p\u003e","brand":"U.S. Solid","offers":[{"title":"NPT","offer_id":47614018355455,"sku":"JFMSV50020","price":171.69,"currency_code":"USD","in_stock":true},{"title":"G","offer_id":47614018388223,"sku":"JFMSV50020-G","price":171.69,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/1_d34f4be6-df3d-40dc-851e-0989627d1ae9.png?v=1778573132"},{"product_id":"1-1-2-upvc-motorized-ball-valve-full-port-9-24v-ac-dc-2-wire-auto-return-ip67-normally-closed-with-manual-reset","title":"1-1\/2\" UPVC Motorized Ball Valve, Full Port, 9–24V AC\/DC, 2-Wire Auto Return, IP67, Normally Closed with Manual Reset","description":"\u003cmeta charset=\"UTF-8\"\u003e\n\u003cmeta name=\"viewport\" content=\"width=device-width, initial-scale=1.0\"\u003e\n\n\u003cstyle\u003e\n.desktop-img { display: block; width: 100%; }\n.mobile-img { display: none; width: 100%; }\n\n.section-title,\n.section-title2,\n.section-title3,\n.section-title4 {\n    font-size: 22px;\n    line-height: 22px;\n    font-weight: bold;\n    margin: 15px 0 10px;\n    font-family: Arial;\n    color: black;\n}\n\n.title-center {\n    text-align: center;\n}\n\n.section-description {\n    font-size: 16px;\n    line-height: 26px;\n    margin: 5px 0;\n    font-family: Arial;\n    color: black;\n}\n\n.section-description2 {\n    font-size: 16px;\n    line-height: 26px;\n    margin: 0;\n    font-family: Arial;\n}\n\n.faq {\n    font-size: 16px;\n    line-height: 26px;\n    padding: 5px;\n    margin: 10px 0 5px;\n    font-family: Arial;\n    color: black;\n}\n\n.warning-title {\n    font-size: 22px;\n    text-align: left;\n    margin-top: 20px;\n    margin-bottom: 10px;\n    line-height: 26px;\n    color: black;\n    font-weight: bold;\n    font-family: Arial;\n  }\n\n  .flex-row {\n    display: flex;\n    gap: 20px;\n    margin: 20px 0;\n}\n\n.flex-item {\n    flex: 1;\n    min-width: 0;\n}\n\n.flex-item img {\n    width: 100%;\n    display: block;\n}\n\n.parameters-table-wrapper {\n    overflow-x: auto;\n    -webkit-overflow-scrolling: touch;\n}\n\n.parameters-table {\n    width: 100%;\n    min-width: 1000px;\n    border-collapse: collapse;\n    font-family: Arial;\n}\n\n.parameters-table th,\n.parameters-table td {\n    border-top: 1.2px solid #a6a6a6;\n    border-bottom: 1.2px solid #a6a6a6;\n    padding: 5px 2px;\n    text-align: left;\n    font-size: 16px;\n}\n\n.parameters-table th,\n.parameters-table .bg-gray {\n    background-color: #f2f2f2;\n    font-weight: bold;\n}\n\n.bg-gray {\n    color: black;\n    font-weight: bold;\n}\n\n@media (max-width: 768px) {\n    .desktop-img { display: none; }\n    .mobile-img { display: block; }\n    .flex-row {\n        flex-direction: column;\n        gap: 10px;\n    }\n    .parameters-table th,\n    .parameters-table td {\n        font-size: 14px;\n    }\n}\n\n@media (max-width: 480px) {\n    .parameters-table th,\n    .parameters-table td {\n        font-size: 12px;\n    }\n}\n\u003c\/style\u003e\n\n\u003c!-- Cover Image --\u003e\n\u003cp\u003e\n  \u003cimg class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" alt=\"\"\u003e\n  \u003cimg class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" alt=\"\"\u003e\n\u003c\/p\u003e\n\n\u003c!-- INTRODUCTION --\u003e\n\u003ch2 class=\"section-title\"\u003eINTRODUCTION\u003c\/h2\u003e\n\u003cp class=\"section-description\"\u003e\nMotorized ball valves are a vital piece of equipment in numerous applications. This model opens and closes in 3-5 seconds, and remains in its new position while expending almost no energy. This is a key difference between motorized ball valves and many solenoid valves. Most solenoid valves are energized continuously when in a new position, while motorized ball valves expend energy only when changing from open to close, or vice versa.\n\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\nThe 2 wire auto return model is perfect for situations where the valve needs to be closed in case of power loss. The valve can be energized to open, and left hooked up, with negligible energy used once fully opened. To close, simply shutoff power to the valve. This valve is convenient because it can be operated with a simple on off switch. When on, it will remain open, when turned off (or power is lost for some other reason) the valve automatically closes.\n\u003c\/p\u003e\n\n\u003c!-- FEATURES --\u003e\n\u003ch2 class=\"section-title\"\u003eFEATURES\u003c\/h2\u003e\n\u003cp\u003e\n  \u003cimg class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/1.png\" alt=\"\"\u003e\n  \u003cimg class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/1.png\" alt=\"\"\u003e\n\u003c\/p\u003e\n\n\u003c!-- MORE DETAILS --\u003e\n\u003ch2 class=\"section-title3\"\u003eMORE DETAILS\u003c\/h2\u003e\n\u003cdiv class=\"flex-row\"\u003e\n    \n    \u003cdiv class=\"flex-item\"\u003e\n        \u003ch2 class=\"section-title4 title-center\"\u003eMANUAL OVERRIDE\u003c\/h2\u003e\n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/jfesm50020-more1.png\" alt=\"GIF 1\"\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"flex-item\"\u003e\n        \u003ch2 class=\"section-title4 title-center\"\u003eDETACHABLE DESIGN\u003c\/h2\u003e\n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/jfesm50020-more2.jpg\" alt=\"GIF 2\"\u003e\n    \u003c\/div\u003e\n\n\u003c\/div\u003e\n\n\u003c!-- APPLICATIONS --\u003e\n\u003ch2 class=\"section-title2\"\u003eAPPLICATIONS\u003c\/h2\u003e\n\u003cp\u003e\n  \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" alt=\"\"\u003e\n\u003c\/p\u003e\n\n\u003c!-- OPERATION PERFORMANCE --\u003e\n\u003ch2 class=\"section-title3\"\u003eOPERATION PERFORMANCE\u003c\/h2\u003e\n\u003cdiv class=\"flex-row\"\u003e\n    \n    \u003cdiv class=\"flex-item\"\u003e\n        \u003ch2 class=\"section-title4 title-center\"\u003eAFTER WIRING\u003c\/h2\u003e\n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 1\"\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"flex-item\"\u003e\n        \u003ch2 class=\"section-title4 title-center\"\u003eDISCONNECT THE WIRING\u003c\/h2\u003e\n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 2\"\u003e\n    \u003c\/div\u003e\n\n\u003c\/div\u003e\n\n\u003c!-- SPECIFICATIONS --\u003e\n\u003ch2 class=\"section-title3\"\u003eSPECIFICATIONS\u003c\/h2\u003e\n\u003cdiv class=\"parameters-table-wrapper\"\u003e\n\u003ctable class=\"parameters-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003eModel\u003c\/td\u003e\n\u003ctd\u003eUSS-MSV50021 \/ USS-MSV50021-G\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eU.S. Solid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003eSize\u003c\/td\u003e\n\u003ctd\u003e1-1\/2\"\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003eWiring Type\u003c\/td\u003e\n\u003ctd\u003e2 Wire Auto Return\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003eValve Material\u003c\/td\u003e\n\u003ctd\u003eUPVC\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003eEnclosure Rating\u003c\/td\u003e\n\u003ctd\u003eIP67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003eOperating Time\u003c\/td\u003e\n\u003ctd\u003e≤12 Seconds\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003eWorking Voltage\u003c\/td\u003e\n\u003ctd\u003e9 - 24V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003eMax Power\u003c\/td\u003e\n\u003ctd\u003e36 W\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003eMax Torque\u003c\/td\u003e\n\u003ctd\u003e15 N m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003eMax Medium Pressure\u003c\/td\u003e\n\u003ctd\u003e1.0 Mpa\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003eTemperature Range for Flow Medium\u003c\/td\u003e\n\u003ctd\u003e2°C to 55°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003eLife Expectancy\u003c\/td\u003e\n\u003ctd\u003e70,000 Cycles\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003eBore Type\u003c\/td\u003e\n\u003ctd\u003eFull\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003eThread Type\u003c\/td\u003e\n\u003ctd\u003eNPT\/G\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003eOperating State\u003c\/td\u003e\n\u003ctd\u003eNormally Closed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003eAmbient Temperature Range\u003c\/td\u003e\n\u003ctd\u003e-15°C to 50°C\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003eBall Seal\u003c\/td\u003e\n\u003ctd\u003ePTFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp class=\"section-description\"\u003e*To view the full table on mobile, please swipe left or right on the screen.\u003c\/p\u003e\n\n\u003c!-- CE CERTIFIED QUALITY \u0026 SAFETY --\u003e\n\u003ch2 class=\"section-title3\"\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/h2\u003e\n\u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/CE\/CE.jpg\"\u003e\n\u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/CE\/CE.jpg\"\u003e\n\n\u003c!-- FAQ --\u003e\n\u003ch2 class=\"section-title\"\u003eFAQ\u003c\/h2\u003e\n\n\u003cp class=\"faq\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\nThe motor's housing is rated at IP67 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\n\u003c\/p\u003e\n\n\u003cp class=\"faq\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\nIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\n\u003c\/p\u003e\n\n\u003cp class=\"faq\"\u003e\u003cb\u003e3. What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\nIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\n\u003c\/p\u003e\n\n\u003cp class=\"faq\"\u003e\u003cb\u003e4. Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\nYES. The motorized ball valve is made of lead-free Polyvinyl Chloride and is NSF certified.\n\u003c\/p\u003e\n\n\u003cp class=\"faq\"\u003e\u003cb\u003e5. For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\nTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\n\u003c\/p\u003e\n\n\u003cp class=\"faq\"\u003e\u003cb\u003e6. Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\nYes, our motorized ball valves are suitable for use with propane.\n\u003c\/p\u003e\n\n\u003c!-- WARNING --\u003e\n\u003ch2 class=\"section-title\"\u003eWARNING\u003c\/h2\u003e\n\n\u003cp class=\"section-description\"\u003e\n\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\n\u003c\/p\u003e\n\n\u003cp class=\"section-description\"\u003e\n\u003cb\u003e2.\u003c\/b\u003e The valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\n\u003c\/p\u003e\n\n\u003cp class=\"section-description\"\u003e\n\u003cb\u003e3.\u003c\/b\u003e Only Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\n\u003c\/p\u003e\n\n\u003cp class=\"section-description\"\u003e\n\u003cb\u003e4.\u003c\/b\u003e While the motorized ball valves have an IP67 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\n\u003c\/p\u003e\n\n\u003cp class=\"section-description\"\u003e\n\u003cb\u003e5.\u003c\/b\u003e These valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\n\u003c\/p\u003e\n\n\u003c!-- Valve Attributes --\u003e\n\u003ch2 class=\"section-title\"\u003eValve Attributes\u003c\/h2\u003e\n\n\u003cp class=\"section-description\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\nNormally Closed: The valve is closed when power is off and opens when power is on.\n\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\nNormally Open: The valve is open when power is off and closes when power is on.\n\u003c\/p\u003e\n\n\u003cp class=\"section-description\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\nFull Port: It has a wide internal passage, resulting in low water - flow resistance.\n\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\nStandard Port: Meets regular usage requirements.\n\u003c\/p\u003e\n\n\u003cp class=\"section-description\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\nThe valves have an ingress - protection rating of IP67. The 6 in IP67 represents complete dust - tightness. The 7 in IP67 indicates protection against water immersion up to 1 meter for 30 minutes. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\n\u003c\/p\u003e\n\u003cp\u003e\n  \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/IP67-UPVC.png\" alt=\"\"\u003e\n\u003c\/p\u003e\n\n\u003c!-- Valve Attributes --\u003e\n\u003ch2 class=\"section-title\"\u003eWIRING SCHEMATICS\u003c\/h2\u003e\n\u003cp\u003e\n  \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" alt=\"\"\u003e\n\u003c\/p\u003e\n\n\u003cp class=\"section-description\"\u003e\n\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\n\u003c\/p\u003e\n\n\u003c!-- CHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS --\u003e\n\u003ch2 class=\"section-title3\"\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS \u0026amp; SAFETY\u003c\/h2\u003e\n\u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material.png\"\u003e\n\u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material-APP.png\"\u003e\n\n\u003cp class=\"section-description\"\u003e\nDownload user manual\n\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/Manual-50020-28.pdf\" target=\"_blank\"\u003ehere\u003c\/a\u003e.\n\u003c\/p\u003e","brand":"U.S. Solid","offers":[{"title":"NPT","offer_id":47614019207423,"sku":"JFMSV50021","price":181.79,"currency_code":"USD","in_stock":true},{"title":"G","offer_id":47614019240191,"sku":"JFMSV50021-G","price":181.69,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/1_c1ee0307-5c60-4197-b523-6d9873d59888.png?v=1778573237"},{"product_id":"2-upvc-motorized-ball-valve-full-port-9-24v-ac-dc-2-wire-auto-return-ip67-normally-closed-with-manual-reset","title":"2\" UPVC Motorized Ball Valve, Full Port, 9–24V AC\/DC, 2-Wire Auto Return, IP67, Normally Closed with Manual Reset","description":"\u003cmeta charset=\"UTF-8\"\u003e\n\u003cmeta name=\"viewport\" content=\"width=device-width, initial-scale=1.0\"\u003e\n\n\u003cstyle\u003e\n.desktop-img { display: block; width: 100%; }\n.mobile-img { display: none; width: 100%; }\n\n.section-title,\n.section-title2,\n.section-title3,\n.section-title4 {\n    font-size: 22px;\n    line-height: 22px;\n    font-weight: bold;\n    margin: 15px 0 10px;\n    font-family: Arial;\n    color: black;\n}\n\n.title-center {\n    text-align: center;\n}\n\n.section-description {\n    font-size: 16px;\n    line-height: 26px;\n    margin: 5px 0;\n    font-family: Arial;\n    color: black;\n}\n\n.section-description2 {\n    font-size: 16px;\n    line-height: 26px;\n    margin: 0;\n    font-family: Arial;\n}\n\n.faq {\n    font-size: 16px;\n    line-height: 26px;\n    padding: 5px;\n    margin: 10px 0 5px;\n    font-family: Arial;\n    color: black;\n}\n\n.warning-title {\n    font-size: 22px;\n    text-align: left;\n    margin-top: 20px;\n    margin-bottom: 10px;\n    line-height: 26px;\n    color: black;\n    font-weight: bold;\n    font-family: Arial;\n  }\n\n  .flex-row {\n    display: flex;\n    gap: 20px;\n    margin: 20px 0;\n}\n\n.flex-item {\n    flex: 1;\n    min-width: 0;\n}\n\n.flex-item img {\n    width: 100%;\n    display: block;\n}\n\n.parameters-table-wrapper {\n    overflow-x: auto;\n    -webkit-overflow-scrolling: touch;\n}\n\n.parameters-table {\n    width: 100%;\n    min-width: 1000px;\n    border-collapse: collapse;\n    font-family: Arial;\n}\n\n.parameters-table th,\n.parameters-table td {\n    border-top: 1.2px solid #a6a6a6;\n    border-bottom: 1.2px solid #a6a6a6;\n    padding: 5px 2px;\n    text-align: left;\n    font-size: 16px;\n}\n\n.parameters-table th,\n.parameters-table .bg-gray {\n    background-color: #f2f2f2;\n    font-weight: bold;\n}\n\n.bg-gray {\n    color: black;\n    font-weight: bold;\n}\n\n@media (max-width: 768px) {\n    .desktop-img { display: none; }\n    .mobile-img { display: block; }\n    .flex-row {\n        flex-direction: column;\n        gap: 10px;\n    }\n    .parameters-table th,\n    .parameters-table td {\n        font-size: 14px;\n    }\n}\n\n@media (max-width: 480px) {\n    .parameters-table th,\n    .parameters-table td {\n        font-size: 12px;\n    }\n}\n\u003c\/style\u003e\n\n\u003c!-- Cover Image --\u003e\n\u003cp\u003e\n  \u003cimg class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" alt=\"\"\u003e\n  \u003cimg class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" alt=\"\"\u003e\n\u003c\/p\u003e\n\n\u003c!-- INTRODUCTION --\u003e\n\u003ch2 class=\"section-title\"\u003eINTRODUCTION\u003c\/h2\u003e\n\u003cp class=\"section-description\"\u003e\nMotorized ball valves are a vital piece of equipment in numerous applications. This model opens and closes in 3-5 seconds, and remains in its new position while expending almost no energy. This is a key difference between motorized ball valves and many solenoid valves. Most solenoid valves are energized continuously when in a new position, while motorized ball valves expend energy only when changing from open to close, or vice versa.\n\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\nThe 2 wire auto return model is perfect for situations where the valve needs to be closed in case of power loss. The valve can be energized to open, and left hooked up, with negligible energy used once fully opened. To close, simply shutoff power to the valve. This valve is convenient because it can be operated with a simple on off switch. When on, it will remain open, when turned off (or power is lost for some other reason) the valve automatically closes.\n\u003c\/p\u003e\n\n\u003c!-- FEATURES --\u003e\n\u003ch2 class=\"section-title\"\u003eFEATURES\u003c\/h2\u003e\n\u003cp\u003e\n  \u003cimg class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/1.png\" alt=\"\"\u003e\n  \u003cimg class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/1.png\" alt=\"\"\u003e\n\u003c\/p\u003e\n\n\u003c!-- MORE DETAILS --\u003e\n\u003ch2 class=\"section-title3\"\u003eMORE DETAILS\u003c\/h2\u003e\n\u003cdiv class=\"flex-row\"\u003e\n    \n    \u003cdiv class=\"flex-item\"\u003e\n        \u003ch2 class=\"section-title4 title-center\"\u003eMANUAL OVERRIDE\u003c\/h2\u003e\n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/jfesm50020-more1.png\" alt=\"GIF 1\"\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"flex-item\"\u003e\n        \u003ch2 class=\"section-title4 title-center\"\u003eDETACHABLE DESIGN\u003c\/h2\u003e\n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/jfesm50020-more2.png\" alt=\"GIF 2\"\u003e\n    \u003c\/div\u003e\n\n\u003c\/div\u003e\n\n\u003c!-- APPLICATIONS --\u003e\n\u003ch2 class=\"section-title2\"\u003eAPPLICATIONS\u003c\/h2\u003e\n\u003cp\u003e\n  \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" alt=\"\"\u003e\n\u003c\/p\u003e\n\n\u003c!-- OPERATION PERFORMANCE --\u003e\n\u003ch2 class=\"section-title3\"\u003eOPERATION PERFORMANCE\u003c\/h2\u003e\n\u003cdiv class=\"flex-row\"\u003e\n    \n    \u003cdiv class=\"flex-item\"\u003e\n        \u003ch2 class=\"section-title4 title-center\"\u003eAFTER WIRING\u003c\/h2\u003e\n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 1\"\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"flex-item\"\u003e\n        \u003ch2 class=\"section-title4 title-center\"\u003eDISCONNECT THE WIRING\u003c\/h2\u003e\n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 2\"\u003e\n    \u003c\/div\u003e\n\n\u003c\/div\u003e\n\n\u003c!-- SPECIFICATIONS --\u003e\n\u003ch2 class=\"section-title3\"\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv class=\"parameters-table-wrapper\"\u003e\n\u003ctable class=\"parameters-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003eModel\u003c\/td\u003e\n\u003ctd\u003eUSS-MSV50022 \/ USS-MSV50022-G\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eU.S. Solid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003eSize\u003c\/td\u003e\n\u003ctd\u003e2\"\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003eWiring Type\u003c\/td\u003e\n\u003ctd\u003e2 Wire Auto Return\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003eValve Material\u003c\/td\u003e\n\u003ctd\u003eUPVC\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003eEnclosure Rating\u003c\/td\u003e\n\u003ctd\u003eIP67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003eOperating Time\u003c\/td\u003e\n\u003ctd\u003e≤12 Seconds\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003eWorking Voltage\u003c\/td\u003e\n\u003ctd\u003e9 - 24V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003eMax Power\u003c\/td\u003e\n\u003ctd\u003e36 W\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003eMax Torque\u003c\/td\u003e\n\u003ctd\u003e15 N m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003eMax Medium Pressure\u003c\/td\u003e\n\u003ctd\u003e1.0 Mpa\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003eTemperature Range for Flow Medium\u003c\/td\u003e\n\u003ctd\u003e2°C to 55°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003eLife Expectancy\u003c\/td\u003e\n\u003ctd\u003e70,000 Cycles\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003eBore Type\u003c\/td\u003e\n\u003ctd\u003eFull\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003eThread Type\u003c\/td\u003e\n\u003ctd\u003eNPT\/G\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003eOperating State\u003c\/td\u003e\n\u003ctd\u003eNormally Closed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003eAmbient Temperature Range\u003c\/td\u003e\n\u003ctd\u003e-15°C to 50°C\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003eBall Seal\u003c\/td\u003e\n\u003ctd\u003ePTFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp class=\"section-description\"\u003e*To view the full table on mobile, please swipe left or right on the screen.\u003c\/p\u003e\n\n\u003c!-- CE CERTIFIED QUALITY \u0026 SAFETY --\u003e\n\u003ch2 class=\"section-title3\"\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/h2\u003e\n\u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/CE\/CE.jpg\"\u003e\n\u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/CE\/CE.jpg\"\u003e\n\n\u003c!-- FAQ --\u003e\n\u003ch2 class=\"section-title\"\u003eFAQ\u003c\/h2\u003e\n\n\u003cp class=\"faq\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\nThe motor's housing is rated at IP67 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\n\u003c\/p\u003e\n\n\u003cp class=\"faq\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\nIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\n\u003c\/p\u003e\n\n\u003cp class=\"faq\"\u003e\u003cb\u003e3. What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\nIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\n\u003c\/p\u003e\n\n\u003cp class=\"faq\"\u003e\u003cb\u003e4. Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\nYES. The motorized ball valve is made of lead-free Polyvinyl Chloride and is NSF certified.\n\u003c\/p\u003e\n\n\u003cp class=\"faq\"\u003e\u003cb\u003e5. For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\nTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\n\u003c\/p\u003e\n\n\u003cp class=\"faq\"\u003e\u003cb\u003e6. Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\nYes, our motorized ball valves are suitable for use with propane.\n\u003c\/p\u003e\n\n\u003c!-- WARNING --\u003e\n\u003ch2 class=\"section-title\"\u003eWARNING\u003c\/h2\u003e\n\n\u003cp class=\"section-description\"\u003e\n\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\n\u003c\/p\u003e\n\n\u003cp class=\"section-description\"\u003e\n\u003cb\u003e2.\u003c\/b\u003e The valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\n\u003c\/p\u003e\n\n\u003cp class=\"section-description\"\u003e\n\u003cb\u003e3.\u003c\/b\u003e Only Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\n\u003c\/p\u003e\n\n\u003cp class=\"section-description\"\u003e\n\u003cb\u003e4.\u003c\/b\u003e While the motorized ball valves have an IP67 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\n\u003c\/p\u003e\n\n\u003cp class=\"section-description\"\u003e\n\u003cb\u003e5.\u003c\/b\u003e These valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\n\u003c\/p\u003e\n\n\u003c!-- Valve Attributes --\u003e\n\u003ch2 class=\"section-title\"\u003eValve Attributes\u003c\/h2\u003e\n\n\u003cp class=\"section-description\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\nNormally Closed: The valve is closed when power is off and opens when power is on.\n\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\nNormally Open: The valve is open when power is off and closes when power is on.\n\u003c\/p\u003e\n\n\u003cp class=\"section-description\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\nFull Port: It has a wide internal passage, resulting in low water - flow resistance.\n\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\nStandard Port: Meets regular usage requirements.\n\u003c\/p\u003e\n\n\u003cp class=\"section-description\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\nThe valves have an ingress - protection rating of IP67. The 6 in IP67 represents complete dust - tightness. The 7 in IP67 indicates protection against water immersion up to 1 meter for 30 minutes. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\n\u003c\/p\u003e\n\u003cp\u003e\n  \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/IP67-UPVC.png\" alt=\"\"\u003e\n\u003c\/p\u003e\n\n\u003c!-- Valve Attributes --\u003e\n\u003ch2 class=\"section-title\"\u003eWIRING SCHEMATICS\u003c\/h2\u003e\n\u003cp\u003e\n  \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" alt=\"\"\u003e\n\u003c\/p\u003e\n\n\u003cp class=\"section-description\"\u003e\n\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\n\u003c\/p\u003e\n\n\u003c!-- CHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS --\u003e\n\u003ch2 class=\"section-title3\"\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS \u0026amp; SAFETY\u003c\/h2\u003e\n\u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material.png\"\u003e\n\u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material-APP.png\"\u003e\n\n\u003cp class=\"section-description\"\u003e\nDownload user manual\n\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/Manual-50020-28.pdf\" target=\"_blank\"\u003ehere\u003c\/a\u003e.\n\u003c\/p\u003e","brand":"U.S. Solid","offers":[{"title":"NPT","offer_id":47614019666175,"sku":"JFMSV50022","price":201.79,"currency_code":"USD","in_stock":true},{"title":"G","offer_id":47614019698943,"sku":"JFMSV50022-G","price":201.69,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/1_f2f8ce5e-6ccc-4dd6-8d50-6621ecc096d3.png?v=1778573362"},{"product_id":"1-2-3-way-upvc-motorized-ball-valve-l-type-9-24v-ac-dc-2-wire-auto-return-ip67-full-port-normally-closed-with-manual-reset","title":"1\/2\" 3 Way UPVC Motorized Ball Valve, L Type, 9–24V AC\/DC, 2-Wire Auto Return, IP67 Full Port, Normally Closed with Manual Reset","description":"\u003cmeta charset=\"UTF-8\"\u003e\n\u003cmeta name=\"viewport\" content=\"width=device-width, initial-scale=1.0\"\u003e\n\n\u003cstyle\u003e\n.desktop-img { display: block; width: 100%; }\n.mobile-img { display: none; width: 100%; }\n\n.section-title,\n.section-title2,\n.section-title3,\n.section-title4 {\n    font-size: 22px;\n    line-height: 22px;\n    font-weight: bold;\n    margin: 15px 0 10px;\n    font-family: Arial;\n    color: black;\n}\n\n.title-center {\n    text-align: center;\n}\n\n.section-description {\n    font-size: 16px;\n    line-height: 26px;\n    margin: 5px 0;\n    font-family: Arial;\n    color: black;\n}\n\n.section-description2 {\n    font-size: 16px;\n    line-height: 26px;\n    margin: 0;\n    font-family: Arial;\n}\n\n.faq {\n    font-size: 16px;\n    line-height: 26px;\n    padding: 5px;\n    margin: 10px 0 5px;\n    font-family: Arial;\n    color: black;\n}\n\n.warning-title {\n    font-size: 22px;\n    text-align: left;\n    margin-top: 20px;\n    margin-bottom: 10px;\n    line-height: 26px;\n    color: black;\n    font-weight: bold;\n    font-family: Arial;\n  }\n\n  .flex-row {\n    display: flex;\n    gap: 20px;\n    margin: 20px 0;\n}\n\n.flex-item {\n    flex: 1;\n    min-width: 0;\n}\n\n.flex-item img {\n    width: 100%;\n    display: block;\n}\n\n.parameters-table-wrapper {\n    overflow-x: auto;\n    -webkit-overflow-scrolling: touch;\n}\n\n.parameters-table {\n    width: 100%;\n    min-width: 1000px;\n    border-collapse: collapse;\n    font-family: Arial;\n}\n\n.parameters-table th,\n.parameters-table td {\n    border-top: 1.2px solid #a6a6a6;\n    border-bottom: 1.2px solid #a6a6a6;\n    padding: 5px 2px;\n    text-align: left;\n    font-size: 16px;\n}\n\n.parameters-table th,\n.parameters-table .bg-gray {\n    background-color: #f2f2f2;\n    font-weight: bold;\n}\n\n.bg-gray {\n    color: black;\n    font-weight: bold;\n}\n\n@media (max-width: 768px) {\n    .desktop-img { display: none; }\n    .mobile-img { display: block; }\n    .flex-row {\n        flex-direction: column;\n        gap: 10px;\n    }\n    .parameters-table th,\n    .parameters-table td {\n        font-size: 14px;\n    }\n}\n\n@media (max-width: 480px) {\n    .parameters-table th,\n    .parameters-table td {\n        font-size: 12px;\n    }\n}\n\u003c\/style\u003e\n\n\u003c!-- Cover Image --\u003e\n\u003cp\u003e\n  \u003cimg class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" alt=\"\"\u003e\n  \u003cimg class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" alt=\"\"\u003e\n\u003c\/p\u003e\n\n\u003c!-- INTRODUCTION --\u003e\n\u003ch2 class=\"section-title\"\u003eINTRODUCTION\u003c\/h2\u003e\n\u003cp class=\"section-description\"\u003e\nMotorized ball valves are a vital piece of equipment in numerous applications. This model opens and closes in 3-5 seconds, and remains in its new position while expending almost no energy. This is a key difference between motorized ball valves and many solenoid valves. Most solenoid valves are energized continuously when in a new position, while motorized ball valves expend energy only when changing from open to close, or vice versa.\n\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\nThe 2 wire auto return model is perfect for situations where the valve needs to be closed in case of power loss. The valve can be energized to open, and left hooked up, with negligible energy used once fully opened. To close, simply shutoff power to the valve. This valve is convenient because it can be operated with a simple on off switch. When on, it will remain open, when turned off (or power is lost for some other reason) the valve automatically closes.\n\u003c\/p\u003e\n\n\u003c!-- FEATURES --\u003e\n\u003ch2 class=\"section-title\"\u003eFEATURES\u003c\/h2\u003e\n\u003cp\u003e\n  \u003cimg class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/1.png\" alt=\"\"\u003e\n  \u003cimg class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/1.png\" alt=\"\"\u003e\n\u003c\/p\u003e\n\n\u003c!-- MORE DETAILS --\u003e\n\u003ch2 class=\"section-title3\"\u003eMORE DETAILS\u003c\/h2\u003e\n\u003cdiv class=\"flex-row\"\u003e\n    \n    \u003cdiv class=\"flex-item\"\u003e\n        \u003ch2 class=\"section-title4 title-center\"\u003eMANUAL OVERRIDE\u003c\/h2\u003e\n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/jfesm50020-more1.png\" alt=\"\"\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"flex-item\"\u003e\n        \u003ch2 class=\"section-title4 title-center\"\u003eDETACHABLE DESIGN\u003c\/h2\u003e\n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/jfesm50023-more.jpg\" alt=\"\"\u003e\n    \u003c\/div\u003e\n\n\u003c\/div\u003e\n\n\u003c!-- APPLICATIONS --\u003e\n\u003ch2 class=\"section-title2\"\u003eAPPLICATIONS\u003c\/h2\u003e\n\u003cp\u003e\n  \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" alt=\"\"\u003e\n\u003c\/p\u003e\n\n\u003c!-- OPERATION PERFORMANCE --\u003e\n\u003ch2 class=\"section-title3\"\u003eOPERATION PERFORMANCE\u003c\/h2\u003e\n\u003cdiv class=\"flex-row\"\u003e\n    \n    \u003cdiv class=\"flex-item\"\u003e\n        \u003ch2 class=\"section-title4 title-center\"\u003eAFTER WIRING\u003c\/h2\u003e\n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 1\"\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"flex-item\"\u003e\n        \u003ch2 class=\"section-title4 title-center\"\u003eDISCONNECT THE WIRING\u003c\/h2\u003e\n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 2\"\u003e\n    \u003c\/div\u003e\n\n\u003c\/div\u003e\n\n\u003c!-- SPECIFICATIONS --\u003e\n\u003ch2 class=\"section-title3\"\u003eSPECIFICATIONS\u003c\/h2\u003e\n\u003cdiv class=\"parameters-table-wrapper\"\u003e\n\u003ctable class=\"parameters-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003eModel\u003c\/td\u003e\n\u003ctd\u003eUSS-MSV50023 \/ USS-MSV50023-G\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eU.S. Solid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003eSize\u003c\/td\u003e\n\u003ctd\u003e1\/2\"\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003eWiring Type\u003c\/td\u003e\n\u003ctd\u003e2 Wire Auto Return\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003eValve Material\u003c\/td\u003e\n\u003ctd\u003eUPVC\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003eEnclosure Rating\u003c\/td\u003e\n\u003ctd\u003eIP67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003eOperating Time\u003c\/td\u003e\n\u003ctd\u003e≤12 Seconds\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003eWorking Voltage\u003c\/td\u003e\n\u003ctd\u003e9 - 24V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003eMax Power\u003c\/td\u003e\n\u003ctd\u003e36 W\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003eMax Torque\u003c\/td\u003e\n\u003ctd\u003e15 N m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003eMax Medium Pressure\u003c\/td\u003e\n\u003ctd\u003e1.0 Mpa\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003eTemperature Range for Flow Medium\u003c\/td\u003e\n\u003ctd\u003e2°C to 55°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003eLife Expectancy\u003c\/td\u003e\n\u003ctd\u003e70,000 Cycles\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003eBore Type\u003c\/td\u003e\n\u003ctd\u003eFull\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003eThread Type\u003c\/td\u003e\n\u003ctd\u003eNPT\/G\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003eOperating State\u003c\/td\u003e\n\u003ctd\u003eNormally Closed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003eAmbient Temperature Range\u003c\/td\u003e\n\u003ctd\u003e-15°C to 50°C\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003eBall Seal\u003c\/td\u003e\n\u003ctd\u003ePTFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp class=\"section-description\"\u003e*To view the full table on mobile, please swipe left or right on the screen.\u003c\/p\u003e\n\n\u003c!-- CE CERTIFIED QUALITY \u0026 SAFETY --\u003e\n\u003ch2 class=\"section-title3\"\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/h2\u003e\n\u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/CE\/CE.jpg\"\u003e\n\u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/CE\/CE.jpg\"\u003e\n\n\u003c!-- FAQ --\u003e\n\u003ch2 class=\"section-title\"\u003eFAQ\u003c\/h2\u003e\n\n\u003cp class=\"faq\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\nThe motor's housing is rated at IP67 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\n\u003c\/p\u003e\n\n\u003cp class=\"faq\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\nIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\n\u003c\/p\u003e\n\n\u003cp class=\"faq\"\u003e\u003cb\u003e3. What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\nIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\n\u003c\/p\u003e\n\n\u003cp class=\"faq\"\u003e\u003cb\u003e4. Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\nYES. The motorized ball valve is made of lead-free Polyvinyl Chloride and is NSF certified.\n\u003c\/p\u003e\n\n\u003cp class=\"faq\"\u003e\u003cb\u003e5. For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\nTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\n\u003c\/p\u003e\n\n\u003cp class=\"faq\"\u003e\u003cb\u003e6. Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\nYes, our motorized ball valves are suitable for use with propane.\n\u003c\/p\u003e\n\n\u003c!-- WARNING --\u003e\n\u003ch2 class=\"section-title\"\u003eWARNING\u003c\/h2\u003e\n\n\u003cp class=\"section-description\"\u003e\n\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\n\u003c\/p\u003e\n\n\u003cp class=\"section-description\"\u003e\n\u003cb\u003e2.\u003c\/b\u003e The valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\n\u003c\/p\u003e\n\n\u003cp class=\"section-description\"\u003e\n\u003cb\u003e3.\u003c\/b\u003e Only Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\n\u003c\/p\u003e\n\n\u003cp class=\"section-description\"\u003e\n\u003cb\u003e4.\u003c\/b\u003e While the motorized ball valves have an IP67 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\n\u003c\/p\u003e\n\n\u003cp class=\"section-description\"\u003e\n\u003cb\u003e5.\u003c\/b\u003e These valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\n\u003c\/p\u003e\n\n\u003c!-- Valve Attributes --\u003e\n\u003ch2 class=\"section-title\"\u003eValve Attributes\u003c\/h2\u003e\n\n\u003cp class=\"section-description\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\nNormally Closed: The valve is closed when power is off and opens when power is on.\n\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\nNormally Open: The valve is open when power is off and closes when power is on.\n\u003c\/p\u003e\n\n\u003cp class=\"section-description\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\nFull Port: It has a wide internal passage, resulting in low water - flow resistance.\n\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\nStandard Port: Meets regular usage requirements.\n\u003c\/p\u003e\n\n\u003cp class=\"section-description\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\nThe valves have an ingress - protection rating of IP67. The 6 in IP67 represents complete dust - tightness. The 7 in IP67 indicates protection against water immersion up to 1 meter for 30 minutes. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\n\u003c\/p\u003e\n\u003cp\u003e\n  \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/IP67-UPVC.png\" alt=\"\"\u003e\n\u003c\/p\u003e\n\n\u003c!-- Valve Attributes --\u003e\n\u003ch2 class=\"section-title\"\u003eWIRING SCHEMATICS\u003c\/h2\u003e\n\u003cp\u003e\n  \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" alt=\"\"\u003e\n\u003c\/p\u003e\n\n\u003cp class=\"section-description\"\u003e\n\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\n\u003c\/p\u003e\n\n\u003c!-- FLOW DIRECTION --\u003e\n\u003ch2 class=\"section-title3\"\u003eFLOW DIRECTION\u003c\/h2\u003e\n\u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/jfesm50023-f.png\"\u003e\n\u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/jfesm50023-f.png\"\u003e\n\n\u003c!-- CHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS --\u003e\n\u003ch2 class=\"section-title3\"\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS \u0026amp; SAFETY\u003c\/h2\u003e\n\u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material.png\"\u003e\n\u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material-APP.png\"\u003e\n\n\u003cp class=\"section-description\"\u003e\nDownload user manual\n\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/Manual-50020-28.pdf\" target=\"_blank\"\u003ehere\u003c\/a\u003e.\n\u003c\/p\u003e","brand":"U.S. Solid","offers":[{"title":"NPT","offer_id":47615636177151,"sku":"JFMSV50023","price":231.89,"currency_code":"USD","in_stock":true},{"title":"G","offer_id":47615636209919,"sku":"JFMSV50023-G","price":231.89,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/1_ef64c431-4e45-4059-9010-e9c3e3d561f0.png?v=1778573537"},{"product_id":"3-4-3-way-upvc-motorized-ball-valve-l-type-9-24v-ac-dc-2-wire-auto-return-ip67-full-port-normally-closed-with-manual-reset","title":"3\/4\" 3 Way UPVC Motorized Ball Valve, L Type, 9–24V AC\/DC, 2-Wire Auto Return, IP67 Full Port, Normally Closed with Manual Reset","description":"\u003cmeta charset=\"UTF-8\"\u003e\n\u003cmeta name=\"viewport\" content=\"width=device-width, initial-scale=1.0\"\u003e\n\n\u003cstyle\u003e\n.desktop-img { display: block; width: 100%; }\n.mobile-img { display: none; width: 100%; }\n\n.section-title,\n.section-title2,\n.section-title3,\n.section-title4 {\n    font-size: 22px;\n    line-height: 22px;\n    font-weight: bold;\n    margin: 15px 0 10px;\n    font-family: Arial;\n    color: black;\n}\n\n.title-center {\n    text-align: center;\n}\n\n.section-description {\n    font-size: 16px;\n    line-height: 26px;\n    margin: 5px 0;\n    font-family: Arial;\n    color: black;\n}\n\n.section-description2 {\n    font-size: 16px;\n    line-height: 26px;\n    margin: 0;\n    font-family: Arial;\n}\n\n.faq {\n    font-size: 16px;\n    line-height: 26px;\n    padding: 5px;\n    margin: 10px 0 5px;\n    font-family: Arial;\n    color: black;\n}\n\n.warning-title {\n    font-size: 22px;\n    text-align: left;\n    margin-top: 20px;\n    margin-bottom: 10px;\n    line-height: 26px;\n    color: black;\n    font-weight: bold;\n    font-family: Arial;\n  }\n\n  .flex-row {\n    display: flex;\n    gap: 20px;\n    margin: 20px 0;\n}\n\n.flex-item {\n    flex: 1;\n    min-width: 0;\n}\n\n.flex-item img {\n    width: 100%;\n    display: block;\n}\n\n.parameters-table-wrapper {\n    overflow-x: auto;\n    -webkit-overflow-scrolling: touch;\n}\n\n.parameters-table {\n    width: 100%;\n    min-width: 1000px;\n    border-collapse: collapse;\n    font-family: Arial;\n}\n\n.parameters-table th,\n.parameters-table td {\n    border-top: 1.2px solid #a6a6a6;\n    border-bottom: 1.2px solid #a6a6a6;\n    padding: 5px 2px;\n    text-align: left;\n    font-size: 16px;\n}\n\n.parameters-table th,\n.parameters-table .bg-gray {\n    background-color: #f2f2f2;\n    font-weight: bold;\n}\n\n.bg-gray {\n    color: black;\n    font-weight: bold;\n}\n\n@media (max-width: 768px) {\n    .desktop-img { display: none; }\n    .mobile-img { display: block; }\n    .flex-row {\n        flex-direction: column;\n        gap: 10px;\n    }\n    .parameters-table th,\n    .parameters-table td {\n        font-size: 14px;\n    }\n}\n\n@media (max-width: 480px) {\n    .parameters-table th,\n    .parameters-table td {\n        font-size: 12px;\n    }\n}\n\u003c\/style\u003e\n\n\u003c!-- Cover Image --\u003e\n\u003cp\u003e\n  \u003cimg class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" alt=\"\"\u003e\n  \u003cimg class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" alt=\"\"\u003e\n\u003c\/p\u003e\n\n\u003c!-- INTRODUCTION --\u003e\n\u003ch2 class=\"section-title\"\u003eINTRODUCTION\u003c\/h2\u003e\n\u003cp class=\"section-description\"\u003e\nMotorized ball valves are a vital piece of equipment in numerous applications. This model opens and closes in 3-5 seconds, and remains in its new position while expending almost no energy. This is a key difference between motorized ball valves and many solenoid valves. Most solenoid valves are energized continuously when in a new position, while motorized ball valves expend energy only when changing from open to close, or vice versa.\n\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\nThe 2 wire auto return model is perfect for situations where the valve needs to be closed in case of power loss. The valve can be energized to open, and left hooked up, with negligible energy used once fully opened. To close, simply shutoff power to the valve. This valve is convenient because it can be operated with a simple on off switch. When on, it will remain open, when turned off (or power is lost for some other reason) the valve automatically closes.\n\u003c\/p\u003e\n\n\u003c!-- FEATURES --\u003e\n\u003ch2 class=\"section-title\"\u003eFEATURES\u003c\/h2\u003e\n\u003cp\u003e\n  \u003cimg class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/1.png\" alt=\"\"\u003e\n  \u003cimg class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/1.png\" alt=\"\"\u003e\n\u003c\/p\u003e\n\n\u003c!-- MORE DETAILS --\u003e\n\u003ch2 class=\"section-title3\"\u003eMORE DETAILS\u003c\/h2\u003e\n\u003cdiv class=\"flex-row\"\u003e\n    \n    \u003cdiv class=\"flex-item\"\u003e\n        \u003ch2 class=\"section-title4 title-center\"\u003eMANUAL OVERRIDE\u003c\/h2\u003e\n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/jfesm50020-more1.png\" alt=\"\"\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"flex-item\"\u003e\n        \u003ch2 class=\"section-title4 title-center\"\u003eDETACHABLE DESIGN\u003c\/h2\u003e\n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/jfesm50023-more.jpg\" alt=\"\"\u003e\n    \u003c\/div\u003e\n\n\u003c\/div\u003e\n\n\u003c!-- APPLICATIONS --\u003e\n\u003ch2 class=\"section-title2\"\u003eAPPLICATIONS\u003c\/h2\u003e\n\u003cp\u003e\n  \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" alt=\"\"\u003e\n\u003c\/p\u003e\n\n\u003c!-- OPERATION PERFORMANCE --\u003e\n\u003ch2 class=\"section-title3\"\u003eOPERATION PERFORMANCE\u003c\/h2\u003e\n\u003cdiv class=\"flex-row\"\u003e\n    \n    \u003cdiv class=\"flex-item\"\u003e\n        \u003ch2 class=\"section-title4 title-center\"\u003eAFTER WIRING\u003c\/h2\u003e\n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 1\"\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"flex-item\"\u003e\n        \u003ch2 class=\"section-title4 title-center\"\u003eDISCONNECT THE WIRING\u003c\/h2\u003e\n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 2\"\u003e\n    \u003c\/div\u003e\n\n\u003c\/div\u003e\n\n\u003c!-- SPECIFICATIONS --\u003e\n\u003ch2 class=\"section-title3\"\u003eSPECIFICATIONS\u003c\/h2\u003e\n\u003cdiv class=\"parameters-table-wrapper\"\u003e\n\u003ctable class=\"parameters-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003eModel\u003c\/td\u003e\n\u003ctd\u003eUSS-MSV50024 \/ USS-MSV50024-G\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eU.S. Solid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003eSize\u003c\/td\u003e\n\u003ctd\u003e3\/4\"\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003eWiring Type\u003c\/td\u003e\n\u003ctd\u003e2 Wire Auto Return\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003eValve Material\u003c\/td\u003e\n\u003ctd\u003eUPVC\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003eEnclosure Rating\u003c\/td\u003e\n\u003ctd\u003eIP67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003eOperating Time\u003c\/td\u003e\n\u003ctd\u003e≤12 Seconds\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003eWorking Voltage\u003c\/td\u003e\n\u003ctd\u003e9 - 24V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003eMax Power\u003c\/td\u003e\n\u003ctd\u003e36 W\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003eMax Torque\u003c\/td\u003e\n\u003ctd\u003e15 N m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003eMax Medium Pressure\u003c\/td\u003e\n\u003ctd\u003e1.0 Mpa\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003eTemperature Range for Flow Medium\u003c\/td\u003e\n\u003ctd\u003e2°C to 55°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003eLife Expectancy\u003c\/td\u003e\n\u003ctd\u003e70,000 Cycles\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003eBore Type\u003c\/td\u003e\n\u003ctd\u003eFull\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003eThread Type\u003c\/td\u003e\n\u003ctd\u003eNPT\/G\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003eOperating State\u003c\/td\u003e\n\u003ctd\u003eNormally Closed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003eAmbient Temperature Range\u003c\/td\u003e\n\u003ctd\u003e-15°C to 50°C\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003eBall Seal\u003c\/td\u003e\n\u003ctd\u003ePTFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp class=\"section-description\"\u003e*To view the full table on mobile, please swipe left or right on the screen.\u003c\/p\u003e\n\n\u003c!-- CE CERTIFIED QUALITY \u0026 SAFETY --\u003e\n\u003ch2 class=\"section-title3\"\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/h2\u003e\n\u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/CE\/CE.jpg\"\u003e\n\u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/CE\/CE.jpg\"\u003e\n\n\u003c!-- FAQ --\u003e\n\u003ch2 class=\"section-title\"\u003eFAQ\u003c\/h2\u003e\n\n\u003cp class=\"faq\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\nThe motor's housing is rated at IP67 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\n\u003c\/p\u003e\n\n\u003cp class=\"faq\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\nIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\n\u003c\/p\u003e\n\n\u003cp class=\"faq\"\u003e\u003cb\u003e3. What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\nIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\n\u003c\/p\u003e\n\n\u003cp class=\"faq\"\u003e\u003cb\u003e4. Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\nYES. The motorized ball valve is made of lead-free Polyvinyl Chloride and is NSF certified.\n\u003c\/p\u003e\n\n\u003cp class=\"faq\"\u003e\u003cb\u003e5. For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\nTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\n\u003c\/p\u003e\n\n\u003cp class=\"faq\"\u003e\u003cb\u003e6. Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\nYes, our motorized ball valves are suitable for use with propane.\n\u003c\/p\u003e\n\n\u003c!-- WARNING --\u003e\n\u003ch2 class=\"section-title\"\u003eWARNING\u003c\/h2\u003e\n\n\u003cp class=\"section-description\"\u003e\n\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\n\u003c\/p\u003e\n\n\u003cp class=\"section-description\"\u003e\n\u003cb\u003e2.\u003c\/b\u003e The valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\n\u003c\/p\u003e\n\n\u003cp class=\"section-description\"\u003e\n\u003cb\u003e3.\u003c\/b\u003e Only Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\n\u003c\/p\u003e\n\n\u003cp class=\"section-description\"\u003e\n\u003cb\u003e4.\u003c\/b\u003e While the motorized ball valves have an IP67 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\n\u003c\/p\u003e\n\n\u003cp class=\"section-description\"\u003e\n\u003cb\u003e5.\u003c\/b\u003e These valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\n\u003c\/p\u003e\n\n\u003c!-- Valve Attributes --\u003e\n\u003ch2 class=\"section-title\"\u003eValve Attributes\u003c\/h2\u003e\n\n\u003cp class=\"section-description\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\nNormally Closed: The valve is closed when power is off and opens when power is on.\n\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\nNormally Open: The valve is open when power is off and closes when power is on.\n\u003c\/p\u003e\n\n\u003cp class=\"section-description\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\nFull Port: It has a wide internal passage, resulting in low water - flow resistance.\n\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\nStandard Port: Meets regular usage requirements.\n\u003c\/p\u003e\n\n\u003cp class=\"section-description\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\nThe valves have an ingress - protection rating of IP67. The 6 in IP67 represents complete dust - tightness. The 7 in IP67 indicates protection against water immersion up to 1 meter for 30 minutes. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\n\u003c\/p\u003e\n\u003cp\u003e\n  \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/IP67-UPVC.png\" alt=\"\"\u003e\n\u003c\/p\u003e\n\n\u003c!-- Valve Attributes --\u003e\n\u003ch2 class=\"section-title\"\u003eWIRING SCHEMATICS\u003c\/h2\u003e\n\u003cp\u003e\n  \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" alt=\"\"\u003e\n\u003c\/p\u003e\n\n\u003cp class=\"section-description\"\u003e\n\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\n\u003c\/p\u003e\n\n\u003c!-- FLOW DIRECTION --\u003e\n\u003ch2 class=\"section-title3\"\u003eFLOW DIRECTION\u003c\/h2\u003e\n\u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/jfesm50023-f.png\"\u003e\n\u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/jfesm50023-f.png\"\u003e\n\n\u003c!-- CHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS --\u003e\n\u003ch2 class=\"section-title3\"\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS \u0026amp; SAFETY\u003c\/h2\u003e\n\u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material.png\"\u003e\n\u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material-APP.png\"\u003e\n\n\u003cp class=\"section-description\"\u003e\nDownload user manual\n\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/Manual-50020-28.pdf\" target=\"_blank\"\u003ehere\u003c\/a\u003e.\n\u003c\/p\u003e","brand":"U.S. Solid","offers":[{"title":"NPT","offer_id":47615636701439,"sku":"JFMSV50024","price":252.49,"currency_code":"USD","in_stock":true},{"title":"G","offer_id":47615636734207,"sku":"JFMSV50024-G","price":252.89,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/1_8a49996d-4b37-43c8-947c-dad58f4f5782.png?v=1778573593"},{"product_id":"1-3-way-upvc-motorized-ball-valve-l-type-9-24v-ac-dc-2-wire-auto-return-ip67-full-port-normally-closed-with-manual-reset","title":"1\" 3 Way UPVC Motorized Ball Valve, L Type, 9–24V AC\/DC, 2-Wire Auto Return, IP67 Full Port, Normally Closed with Manual Reset","description":"\u003cmeta charset=\"UTF-8\"\u003e\n\u003cmeta name=\"viewport\" content=\"width=device-width, initial-scale=1.0\"\u003e\n\n\u003cstyle\u003e\n.desktop-img { display: block; width: 100%; }\n.mobile-img { display: none; width: 100%; }\n\n.section-title,\n.section-title2,\n.section-title3,\n.section-title4 {\n    font-size: 22px;\n    line-height: 22px;\n    font-weight: bold;\n    margin: 15px 0 10px;\n    font-family: Arial;\n    color: black;\n}\n\n.title-center {\n    text-align: center;\n}\n\n.section-description {\n    font-size: 16px;\n    line-height: 26px;\n    margin: 5px 0;\n    font-family: Arial;\n    color: black;\n}\n\n.section-description2 {\n    font-size: 16px;\n    line-height: 26px;\n    margin: 0;\n    font-family: Arial;\n}\n\n.faq {\n    font-size: 16px;\n    line-height: 26px;\n    padding: 5px;\n    margin: 10px 0 5px;\n    font-family: Arial;\n    color: black;\n}\n\n.warning-title {\n    font-size: 22px;\n    text-align: left;\n    margin-top: 20px;\n    margin-bottom: 10px;\n    line-height: 26px;\n    color: black;\n    font-weight: bold;\n    font-family: Arial;\n  }\n\n  .flex-row {\n    display: flex;\n    gap: 20px;\n    margin: 20px 0;\n}\n\n.flex-item {\n    flex: 1;\n    min-width: 0;\n}\n\n.flex-item img {\n    width: 100%;\n    display: block;\n}\n\n.parameters-table-wrapper {\n    overflow-x: auto;\n    -webkit-overflow-scrolling: touch;\n}\n\n.parameters-table {\n    width: 100%;\n    min-width: 1000px;\n    border-collapse: collapse;\n    font-family: Arial;\n}\n\n.parameters-table th,\n.parameters-table td {\n    border-top: 1.2px solid #a6a6a6;\n    border-bottom: 1.2px solid #a6a6a6;\n    padding: 5px 2px;\n    text-align: left;\n    font-size: 16px;\n}\n\n.parameters-table th,\n.parameters-table .bg-gray {\n    background-color: #f2f2f2;\n    font-weight: bold;\n}\n\n.bg-gray {\n    color: black;\n    font-weight: bold;\n}\n\n@media (max-width: 768px) {\n    .desktop-img { display: none; }\n    .mobile-img { display: block; }\n    .flex-row {\n        flex-direction: column;\n        gap: 10px;\n    }\n    .parameters-table th,\n    .parameters-table td {\n        font-size: 14px;\n    }\n}\n\n@media (max-width: 480px) {\n    .parameters-table th,\n    .parameters-table td {\n        font-size: 12px;\n    }\n}\n\u003c\/style\u003e\n\n\u003c!-- Cover Image --\u003e\n\u003cp\u003e\n  \u003cimg class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" alt=\"\"\u003e\n  \u003cimg class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" alt=\"\"\u003e\n\u003c\/p\u003e\n\n\u003c!-- INTRODUCTION --\u003e\n\u003ch2 class=\"section-title\"\u003eINTRODUCTION\u003c\/h2\u003e\n\u003cp class=\"section-description\"\u003e\nMotorized ball valves are a vital piece of equipment in numerous applications. This model opens and closes in 3-5 seconds, and remains in its new position while expending almost no energy. This is a key difference between motorized ball valves and many solenoid valves. Most solenoid valves are energized continuously when in a new position, while motorized ball valves expend energy only when changing from open to close, or vice versa.\n\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\nThe 2 wire auto return model is perfect for situations where the valve needs to be closed in case of power loss. The valve can be energized to open, and left hooked up, with negligible energy used once fully opened. To close, simply shutoff power to the valve. This valve is convenient because it can be operated with a simple on off switch. When on, it will remain open, when turned off (or power is lost for some other reason) the valve automatically closes.\n\u003c\/p\u003e\n\n\u003c!-- FEATURES --\u003e\n\u003ch2 class=\"section-title\"\u003eFEATURES\u003c\/h2\u003e\n\u003cp\u003e\n  \u003cimg class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/1.png\" alt=\"\"\u003e\n  \u003cimg class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/1.png\" alt=\"\"\u003e\n\u003c\/p\u003e\n\n\u003c!-- MORE DETAILS --\u003e\n\u003ch2 class=\"section-title3\"\u003eMORE DETAILS\u003c\/h2\u003e\n\u003cdiv class=\"flex-row\"\u003e\n    \n    \u003cdiv class=\"flex-item\"\u003e\n        \u003ch2 class=\"section-title4 title-center\"\u003eMANUAL OVERRIDE\u003c\/h2\u003e\n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/jfesm50020-more1.png\" alt=\"\"\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"flex-item\"\u003e\n        \u003ch2 class=\"section-title4 title-center\"\u003eDETACHABLE DESIGN\u003c\/h2\u003e\n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/jfesm50023-more.jpg\" alt=\"\"\u003e\n    \u003c\/div\u003e\n\n\u003c\/div\u003e\n\n\u003c!-- APPLICATIONS --\u003e\n\u003ch2 class=\"section-title2\"\u003eAPPLICATIONS\u003c\/h2\u003e\n\u003cp\u003e\n  \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" alt=\"\"\u003e\n\u003c\/p\u003e\n\n\u003c!-- OPERATION PERFORMANCE --\u003e\n\u003ch2 class=\"section-title3\"\u003eOPERATION PERFORMANCE\u003c\/h2\u003e\n\u003cdiv class=\"flex-row\"\u003e\n    \n    \u003cdiv class=\"flex-item\"\u003e\n        \u003ch2 class=\"section-title4 title-center\"\u003eAFTER WIRING\u003c\/h2\u003e\n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 1\"\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"flex-item\"\u003e\n        \u003ch2 class=\"section-title4 title-center\"\u003eDISCONNECT THE WIRING\u003c\/h2\u003e\n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 2\"\u003e\n    \u003c\/div\u003e\n\n\u003c\/div\u003e\n\n\u003c!-- SPECIFICATIONS --\u003e\n\u003ch2 class=\"section-title3\"\u003eSPECIFICATIONS\u003c\/h2\u003e\n\u003cdiv class=\"parameters-table-wrapper\"\u003e\n\u003ctable class=\"parameters-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003eModel\u003c\/td\u003e\n\u003ctd\u003eUSS-MSV50025 \/ USS-MSV50025-G\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eU.S. Solid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003eSize\u003c\/td\u003e\n\u003ctd\u003e1\"\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003eWiring Type\u003c\/td\u003e\n\u003ctd\u003e2 Wire Auto Return\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003eValve Material\u003c\/td\u003e\n\u003ctd\u003eUPVC\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003eEnclosure Rating\u003c\/td\u003e\n\u003ctd\u003eIP67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003eOperating Time\u003c\/td\u003e\n\u003ctd\u003e≤12 Seconds\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003eWorking Voltage\u003c\/td\u003e\n\u003ctd\u003e9 - 24V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003eMax Power\u003c\/td\u003e\n\u003ctd\u003e36 W\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003eMax Torque\u003c\/td\u003e\n\u003ctd\u003e15 N m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003eMax Medium Pressure\u003c\/td\u003e\n\u003ctd\u003e1.0 Mpa\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003eTemperature Range for Flow Medium\u003c\/td\u003e\n\u003ctd\u003e2°C to 55°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003eLife Expectancy\u003c\/td\u003e\n\u003ctd\u003e70,000 Cycles\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003eBore Type\u003c\/td\u003e\n\u003ctd\u003eFull\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003eThread Type\u003c\/td\u003e\n\u003ctd\u003eNPT\/G\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003eOperating State\u003c\/td\u003e\n\u003ctd\u003eNormally Closed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003eAmbient Temperature Range\u003c\/td\u003e\n\u003ctd\u003e-15°C to 50°C\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003eBall Seal\u003c\/td\u003e\n\u003ctd\u003ePTFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp class=\"section-description\"\u003e*To view the full table on mobile, please swipe left or right on the screen.\u003c\/p\u003e\n\n\u003c!-- CE CERTIFIED QUALITY \u0026 SAFETY --\u003e\n\u003ch2 class=\"section-title3\"\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/h2\u003e\n\u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/CE\/CE.jpg\"\u003e\n\u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/CE\/CE.jpg\"\u003e\n\n\u003c!-- FAQ --\u003e\n\u003ch2 class=\"section-title\"\u003eFAQ\u003c\/h2\u003e\n\n\u003cp class=\"faq\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\nThe motor's housing is rated at IP67 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\n\u003c\/p\u003e\n\n\u003cp class=\"faq\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\nIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\n\u003c\/p\u003e\n\n\u003cp class=\"faq\"\u003e\u003cb\u003e3. What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\nIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\n\u003c\/p\u003e\n\n\u003cp class=\"faq\"\u003e\u003cb\u003e4. Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\nYES. The motorized ball valve is made of lead-free Polyvinyl Chloride and is NSF certified.\n\u003c\/p\u003e\n\n\u003cp class=\"faq\"\u003e\u003cb\u003e5. For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\nTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\n\u003c\/p\u003e\n\n\u003cp class=\"faq\"\u003e\u003cb\u003e6. Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\nYes, our motorized ball valves are suitable for use with propane.\n\u003c\/p\u003e\n\n\u003c!-- WARNING --\u003e\n\u003ch2 class=\"section-title\"\u003eWARNING\u003c\/h2\u003e\n\n\u003cp class=\"section-description\"\u003e\n\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\n\u003c\/p\u003e\n\n\u003cp class=\"section-description\"\u003e\n\u003cb\u003e2.\u003c\/b\u003e The valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\n\u003c\/p\u003e\n\n\u003cp class=\"section-description\"\u003e\n\u003cb\u003e3.\u003c\/b\u003e Only Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\n\u003c\/p\u003e\n\n\u003cp class=\"section-description\"\u003e\n\u003cb\u003e4.\u003c\/b\u003e While the motorized ball valves have an IP67 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\n\u003c\/p\u003e\n\n\u003cp class=\"section-description\"\u003e\n\u003cb\u003e5.\u003c\/b\u003e These valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\n\u003c\/p\u003e\n\n\u003c!-- Valve Attributes --\u003e\n\u003ch2 class=\"section-title\"\u003eValve Attributes\u003c\/h2\u003e\n\n\u003cp class=\"section-description\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\nNormally Closed: The valve is closed when power is off and opens when power is on.\n\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\nNormally Open: The valve is open when power is off and closes when power is on.\n\u003c\/p\u003e\n\n\u003cp class=\"section-description\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\nFull Port: It has a wide internal passage, resulting in low water - flow resistance.\n\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\nStandard Port: Meets regular usage requirements.\n\u003c\/p\u003e\n\n\u003cp class=\"section-description\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\nThe valves have an ingress - protection rating of IP67. The 6 in IP67 represents complete dust - tightness. The 7 in IP67 indicates protection against water immersion up to 1 meter for 30 minutes. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\n\u003c\/p\u003e\n\u003cp\u003e\n  \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/IP67-UPVC.png\" alt=\"\"\u003e\n\u003c\/p\u003e\n\n\u003c!-- Valve Attributes --\u003e\n\u003ch2 class=\"section-title\"\u003eWIRING SCHEMATICS\u003c\/h2\u003e\n\u003cp\u003e\n  \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" alt=\"\"\u003e\n\u003c\/p\u003e\n\n\u003cp class=\"section-description\"\u003e\n\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\n\u003c\/p\u003e\n\n\u003c!-- FLOW DIRECTION --\u003e\n\u003ch2 class=\"section-title3\"\u003eFLOW DIRECTION\u003c\/h2\u003e\n\u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/jfesm50023-f.png\"\u003e\n\u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/jfesm50023-f.png\"\u003e\n\n\u003c!-- CHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS --\u003e\n\u003ch2 class=\"section-title3\"\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS \u0026amp; SAFETY\u003c\/h2\u003e\n\u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material.png\"\u003e\n\u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material-APP.png\"\u003e\n\n\u003cp class=\"section-description\"\u003e\nDownload user manual\n\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/Manual-50020-28.pdf\" target=\"_blank\"\u003ehere\u003c\/a\u003e.\n\u003c\/p\u003e","brand":"U.S. Solid","offers":[{"title":"NPT","offer_id":47615645483263,"sku":"JFMSV50025","price":272.89,"currency_code":"USD","in_stock":true},{"title":"G","offer_id":47615645516031,"sku":"JFMSV50025-G","price":272.89,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/1_54693068-0a0c-48a8-80d1-80a021e89781.png?v=1778573682"},{"product_id":"1-1-4-3-way-upvc-motorized-ball-valve-l-type-9-24v-ac-dc-2-wire-auto-return-ip67-full-port-normally-closed-with-manual-reset","title":"1-1\/4\" 3 Way UPVC Motorized Ball Valve, L Type, 9–24V AC\/DC, 2-Wire Auto Return, IP67 Full Port, Normally Closed with Manual Reset","description":"\u003cmeta charset=\"UTF-8\"\u003e\n\u003cmeta name=\"viewport\" content=\"width=device-width, initial-scale=1.0\"\u003e\n\n\u003cstyle\u003e\n.desktop-img { display: block; width: 100%; }\n.mobile-img { display: none; width: 100%; }\n\n.section-title,\n.section-title2,\n.section-title3,\n.section-title4 {\n    font-size: 22px;\n    line-height: 22px;\n    font-weight: bold;\n    margin: 15px 0 10px;\n    font-family: Arial;\n    color: black;\n}\n\n.title-center {\n    text-align: center;\n}\n\n.section-description {\n    font-size: 16px;\n    line-height: 26px;\n    margin: 5px 0;\n    font-family: Arial;\n    color: black;\n}\n\n.section-description2 {\n    font-size: 16px;\n    line-height: 26px;\n    margin: 0;\n    font-family: Arial;\n}\n\n.faq {\n    font-size: 16px;\n    line-height: 26px;\n    padding: 5px;\n    margin: 10px 0 5px;\n    font-family: Arial;\n    color: black;\n}\n\n.warning-title {\n    font-size: 22px;\n    text-align: left;\n    margin-top: 20px;\n    margin-bottom: 10px;\n    line-height: 26px;\n    color: black;\n    font-weight: bold;\n    font-family: Arial;\n  }\n\n  .flex-row {\n    display: flex;\n    gap: 20px;\n    margin: 20px 0;\n}\n\n.flex-item {\n    flex: 1;\n    min-width: 0;\n}\n\n.flex-item img {\n    width: 100%;\n    display: block;\n}\n\n.parameters-table-wrapper {\n    overflow-x: auto;\n    -webkit-overflow-scrolling: touch;\n}\n\n.parameters-table {\n    width: 100%;\n    min-width: 1000px;\n    border-collapse: collapse;\n    font-family: Arial;\n}\n\n.parameters-table th,\n.parameters-table td {\n    border-top: 1.2px solid #a6a6a6;\n    border-bottom: 1.2px solid #a6a6a6;\n    padding: 5px 2px;\n    text-align: left;\n    font-size: 16px;\n}\n\n.parameters-table th,\n.parameters-table .bg-gray {\n    background-color: #f2f2f2;\n    font-weight: bold;\n}\n\n.bg-gray {\n    color: black;\n    font-weight: bold;\n}\n\n@media (max-width: 768px) {\n    .desktop-img { display: none; }\n    .mobile-img { display: block; }\n    .flex-row {\n        flex-direction: column;\n        gap: 10px;\n    }\n    .parameters-table th,\n    .parameters-table td {\n        font-size: 14px;\n    }\n}\n\n@media (max-width: 480px) {\n    .parameters-table th,\n    .parameters-table td {\n        font-size: 12px;\n    }\n}\n\u003c\/style\u003e\n\n\u003c!-- Cover Image --\u003e\n\u003cp\u003e\n  \u003cimg class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" alt=\"\"\u003e\n  \u003cimg class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" alt=\"\"\u003e\n\u003c\/p\u003e\n\n\u003c!-- INTRODUCTION --\u003e\n\u003ch2 class=\"section-title\"\u003eINTRODUCTION\u003c\/h2\u003e\n\u003cp class=\"section-description\"\u003e\nMotorized ball valves are a vital piece of equipment in numerous applications. This model opens and closes in 3-5 seconds, and remains in its new position while expending almost no energy. This is a key difference between motorized ball valves and many solenoid valves. Most solenoid valves are energized continuously when in a new position, while motorized ball valves expend energy only when changing from open to close, or vice versa.\n\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\nThe 2 wire auto return model is perfect for situations where the valve needs to be closed in case of power loss. The valve can be energized to open, and left hooked up, with negligible energy used once fully opened. To close, simply shutoff power to the valve. This valve is convenient because it can be operated with a simple on off switch. When on, it will remain open, when turned off (or power is lost for some other reason) the valve automatically closes.\n\u003c\/p\u003e\n\n\u003c!-- FEATURES --\u003e\n\u003ch2 class=\"section-title\"\u003eFEATURES\u003c\/h2\u003e\n\u003cp\u003e\n  \u003cimg class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/1.png\" alt=\"\"\u003e\n  \u003cimg class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/1.png\" alt=\"\"\u003e\n\u003c\/p\u003e\n\n\u003c!-- MORE DETAILS --\u003e\n\u003ch2 class=\"section-title3\"\u003eMORE DETAILS\u003c\/h2\u003e\n\u003cdiv class=\"flex-row\"\u003e\n    \n    \u003cdiv class=\"flex-item\"\u003e\n        \u003ch2 class=\"section-title4 title-center\"\u003eMANUAL OVERRIDE\u003c\/h2\u003e\n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/jfesm50020-more1.png\" alt=\"\"\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"flex-item\"\u003e\n        \u003ch2 class=\"section-title4 title-center\"\u003eDETACHABLE DESIGN\u003c\/h2\u003e\n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/jfesm50023-more.jpg\" alt=\"\"\u003e\n    \u003c\/div\u003e\n\n\u003c\/div\u003e\n\n\u003c!-- APPLICATIONS --\u003e\n\u003ch2 class=\"section-title2\"\u003eAPPLICATIONS\u003c\/h2\u003e\n\u003cp\u003e\n  \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" alt=\"\"\u003e\n\u003c\/p\u003e\n\n\u003c!-- OPERATION PERFORMANCE --\u003e\n\u003ch2 class=\"section-title3\"\u003eOPERATION PERFORMANCE\u003c\/h2\u003e\n\u003cdiv class=\"flex-row\"\u003e\n    \n    \u003cdiv class=\"flex-item\"\u003e\n        \u003ch2 class=\"section-title4 title-center\"\u003eAFTER WIRING\u003c\/h2\u003e\n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 1\"\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"flex-item\"\u003e\n        \u003ch2 class=\"section-title4 title-center\"\u003eDISCONNECT THE WIRING\u003c\/h2\u003e\n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 2\"\u003e\n    \u003c\/div\u003e\n\n\u003c\/div\u003e\n\n\u003c!-- SPECIFICATIONS --\u003e\n\u003ch2 class=\"section-title3\"\u003eSPECIFICATIONS\u003c\/h2\u003e\n\u003cdiv class=\"parameters-table-wrapper\"\u003e\n\u003ctable class=\"parameters-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003eModel\u003c\/td\u003e\n\u003ctd\u003eUSS-MSV50026 \/ USS-MSV50026-G\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eU.S. Solid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003eSize\u003c\/td\u003e\n\u003ctd\u003e1-1\/4\"\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003eWiring Type\u003c\/td\u003e\n\u003ctd\u003e2 Wire Auto Return\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003eValve Material\u003c\/td\u003e\n\u003ctd\u003eUPVC\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003eEnclosure Rating\u003c\/td\u003e\n\u003ctd\u003eIP67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003eOperating Time\u003c\/td\u003e\n\u003ctd\u003e≤12 Seconds\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003eWorking Voltage\u003c\/td\u003e\n\u003ctd\u003e9 - 24V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003eMax Power\u003c\/td\u003e\n\u003ctd\u003e36 W\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003eMax Torque\u003c\/td\u003e\n\u003ctd\u003e15 N m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003eMax Medium Pressure\u003c\/td\u003e\n\u003ctd\u003e1.0 Mpa\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003eTemperature Range for Flow Medium\u003c\/td\u003e\n\u003ctd\u003e2°C to 55°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003eLife Expectancy\u003c\/td\u003e\n\u003ctd\u003e70,000 Cycles\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003eBore Type\u003c\/td\u003e\n\u003ctd\u003eFull\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003eThread Type\u003c\/td\u003e\n\u003ctd\u003eNPT\/G\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003eOperating State\u003c\/td\u003e\n\u003ctd\u003eNormally Closed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003eAmbient Temperature Range\u003c\/td\u003e\n\u003ctd\u003e-15°C to 50°C\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003eBall Seal\u003c\/td\u003e\n\u003ctd\u003ePTFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp class=\"section-description\"\u003e*To view the full table on mobile, please swipe left or right on the screen.\u003c\/p\u003e\n\n\u003c!-- CE CERTIFIED QUALITY \u0026 SAFETY --\u003e\n\u003ch2 class=\"section-title3\"\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/h2\u003e\n\u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/CE\/CE.jpg\"\u003e\n\u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/CE\/CE.jpg\"\u003e\n\n\u003c!-- FAQ --\u003e\n\u003ch2 class=\"section-title\"\u003eFAQ\u003c\/h2\u003e\n\n\u003cp class=\"faq\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\nThe motor's housing is rated at IP67 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\n\u003c\/p\u003e\n\n\u003cp class=\"faq\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\nIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\n\u003c\/p\u003e\n\n\u003cp class=\"faq\"\u003e\u003cb\u003e3. What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\nIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\n\u003c\/p\u003e\n\n\u003cp class=\"faq\"\u003e\u003cb\u003e4. Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\nYES. The motorized ball valve is made of lead-free Polyvinyl Chloride and is NSF certified.\n\u003c\/p\u003e\n\n\u003cp class=\"faq\"\u003e\u003cb\u003e5. For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\nTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\n\u003c\/p\u003e\n\n\u003cp class=\"faq\"\u003e\u003cb\u003e6. Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\nYes, our motorized ball valves are suitable for use with propane.\n\u003c\/p\u003e\n\n\u003c!-- WARNING --\u003e\n\u003ch2 class=\"section-title\"\u003eWARNING\u003c\/h2\u003e\n\n\u003cp class=\"section-description\"\u003e\n\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\n\u003c\/p\u003e\n\n\u003cp class=\"section-description\"\u003e\n\u003cb\u003e2.\u003c\/b\u003e The valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\n\u003c\/p\u003e\n\n\u003cp class=\"section-description\"\u003e\n\u003cb\u003e3.\u003c\/b\u003e Only Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\n\u003c\/p\u003e\n\n\u003cp class=\"section-description\"\u003e\n\u003cb\u003e4.\u003c\/b\u003e While the motorized ball valves have an IP67 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\n\u003c\/p\u003e\n\n\u003cp class=\"section-description\"\u003e\n\u003cb\u003e5.\u003c\/b\u003e These valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\n\u003c\/p\u003e\n\n\u003c!-- Valve Attributes --\u003e\n\u003ch2 class=\"section-title\"\u003eValve Attributes\u003c\/h2\u003e\n\n\u003cp class=\"section-description\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\nNormally Closed: The valve is closed when power is off and opens when power is on.\n\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\nNormally Open: The valve is open when power is off and closes when power is on.\n\u003c\/p\u003e\n\n\u003cp class=\"section-description\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\nFull Port: It has a wide internal passage, resulting in low water - flow resistance.\n\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\nStandard Port: Meets regular usage requirements.\n\u003c\/p\u003e\n\n\u003cp class=\"section-description\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\nThe valves have an ingress - protection rating of IP67. The 6 in IP67 represents complete dust - tightness. The 7 in IP67 indicates protection against water immersion up to 1 meter for 30 minutes. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\n\u003c\/p\u003e\n\u003cp\u003e\n  \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/IP67-UPVC.png\" alt=\"\"\u003e\n\u003c\/p\u003e\n\n\u003c!-- Valve Attributes --\u003e\n\u003ch2 class=\"section-title\"\u003eWIRING SCHEMATICS\u003c\/h2\u003e\n\u003cp\u003e\n  \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" alt=\"\"\u003e\n\u003c\/p\u003e\n\n\u003cp class=\"section-description\"\u003e\n\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\n\u003c\/p\u003e\n\n\u003c!-- FLOW DIRECTION --\u003e\n\u003ch2 class=\"section-title3\"\u003eFLOW DIRECTION\u003c\/h2\u003e\n\u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/jfesm50023-f.png\"\u003e\n\u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/jfesm50023-f.png\"\u003e\n\n\u003c!-- CHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS --\u003e\n\u003ch2 class=\"section-title3\"\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS \u0026amp; SAFETY\u003c\/h2\u003e\n\u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material.png\"\u003e\n\u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material-APP.png\"\u003e\n\n\u003cp class=\"section-description\"\u003e\nDownload user manual\n\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/Manual-50020-28.pdf\" target=\"_blank\"\u003ehere\u003c\/a\u003e.\n\u003c\/p\u003e","brand":"U.S. Solid","offers":[{"title":"NPT","offer_id":47615650103551,"sku":"JFMSV50026","price":292.89,"currency_code":"USD","in_stock":true},{"title":"G","offer_id":47615650136319,"sku":"JFMSV50026-G","price":292.89,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/1_1d4c0b77-2ffb-4e2c-8bf4-fe34c17c7c6b.png?v=1778573685"},{"product_id":"1-1-2-3-way-upvc-motorized-ball-valve-l-type-9-24v-ac-dc-2-wire-auto-return-ip67-full-port-normally-closed-with-manual-reset","title":"1-1\/2\" 3 Way UPVC Motorized Ball Valve, L Type, 9–24V AC\/DC, 2-Wire Auto Return, IP67 Full Port, Normally Closed with Manual Reset","description":"\u003cmeta charset=\"UTF-8\"\u003e\n\u003cmeta name=\"viewport\" content=\"width=device-width, initial-scale=1.0\"\u003e\n\n\u003cstyle\u003e\n.desktop-img { display: block; width: 100%; }\n.mobile-img { display: none; width: 100%; }\n\n.section-title,\n.section-title2,\n.section-title3,\n.section-title4 {\n    font-size: 22px;\n    line-height: 22px;\n    font-weight: bold;\n    margin: 15px 0 10px;\n    font-family: Arial;\n    color: black;\n}\n\n.title-center {\n    text-align: center;\n}\n\n.section-description {\n    font-size: 16px;\n    line-height: 26px;\n    margin: 5px 0;\n    font-family: Arial;\n    color: black;\n}\n\n.section-description2 {\n    font-size: 16px;\n    line-height: 26px;\n    margin: 0;\n    font-family: Arial;\n}\n\n.faq {\n    font-size: 16px;\n    line-height: 26px;\n    padding: 5px;\n    margin: 10px 0 5px;\n    font-family: Arial;\n    color: black;\n}\n\n.warning-title {\n    font-size: 22px;\n    text-align: left;\n    margin-top: 20px;\n    margin-bottom: 10px;\n    line-height: 26px;\n    color: black;\n    font-weight: bold;\n    font-family: Arial;\n  }\n\n  .flex-row {\n    display: flex;\n    gap: 20px;\n    margin: 20px 0;\n}\n\n.flex-item {\n    flex: 1;\n    min-width: 0;\n}\n\n.flex-item img {\n    width: 100%;\n    display: block;\n}\n\n.parameters-table-wrapper {\n    overflow-x: auto;\n    -webkit-overflow-scrolling: touch;\n}\n\n.parameters-table {\n    width: 100%;\n    min-width: 1000px;\n    border-collapse: collapse;\n    font-family: Arial;\n}\n\n.parameters-table th,\n.parameters-table td {\n    border-top: 1.2px solid #a6a6a6;\n    border-bottom: 1.2px solid #a6a6a6;\n    padding: 5px 2px;\n    text-align: left;\n    font-size: 16px;\n}\n\n.parameters-table th,\n.parameters-table .bg-gray {\n    background-color: #f2f2f2;\n    font-weight: bold;\n}\n\n.bg-gray {\n    color: black;\n    font-weight: bold;\n}\n\n@media (max-width: 768px) {\n    .desktop-img { display: none; }\n    .mobile-img { display: block; }\n    .flex-row {\n        flex-direction: column;\n        gap: 10px;\n    }\n    .parameters-table th,\n    .parameters-table td {\n        font-size: 14px;\n    }\n}\n\n@media (max-width: 480px) {\n    .parameters-table th,\n    .parameters-table td {\n        font-size: 12px;\n    }\n}\n\u003c\/style\u003e\n\n\u003c!-- Cover Image --\u003e\n\u003cp\u003e\n  \u003cimg class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" alt=\"\"\u003e\n  \u003cimg class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" alt=\"\"\u003e\n\u003c\/p\u003e\n\n\u003c!-- INTRODUCTION --\u003e\n\u003ch2 class=\"section-title\"\u003eINTRODUCTION\u003c\/h2\u003e\n\u003cp class=\"section-description\"\u003e\nMotorized ball valves are a vital piece of equipment in numerous applications. This model opens and closes in 3-5 seconds, and remains in its new position while expending almost no energy. This is a key difference between motorized ball valves and many solenoid valves. Most solenoid valves are energized continuously when in a new position, while motorized ball valves expend energy only when changing from open to close, or vice versa.\n\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\nThe 2 wire auto return model is perfect for situations where the valve needs to be closed in case of power loss. The valve can be energized to open, and left hooked up, with negligible energy used once fully opened. To close, simply shutoff power to the valve. This valve is convenient because it can be operated with a simple on off switch. When on, it will remain open, when turned off (or power is lost for some other reason) the valve automatically closes.\n\u003c\/p\u003e\n\n\u003c!-- FEATURES --\u003e\n\u003ch2 class=\"section-title\"\u003eFEATURES\u003c\/h2\u003e\n\u003cp\u003e\n  \u003cimg class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/1.png\" alt=\"\"\u003e\n  \u003cimg class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/1.png\" alt=\"\"\u003e\n\u003c\/p\u003e\n\n\u003c!-- MORE DETAILS --\u003e\n\u003ch2 class=\"section-title3\"\u003eMORE DETAILS\u003c\/h2\u003e\n\u003cdiv class=\"flex-row\"\u003e\n    \n    \u003cdiv class=\"flex-item\"\u003e\n        \u003ch2 class=\"section-title4 title-center\"\u003eMANUAL OVERRIDE\u003c\/h2\u003e\n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/jfesm50020-more1.png\" alt=\"\"\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"flex-item\"\u003e\n        \u003ch2 class=\"section-title4 title-center\"\u003eDETACHABLE DESIGN\u003c\/h2\u003e\n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/jfesm50023-more.jpg\" alt=\"\"\u003e\n    \u003c\/div\u003e\n\n\u003c\/div\u003e\n\n\u003c!-- APPLICATIONS --\u003e\n\u003ch2 class=\"section-title2\"\u003eAPPLICATIONS\u003c\/h2\u003e\n\u003cp\u003e\n  \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" alt=\"\"\u003e\n\u003c\/p\u003e\n\n\u003c!-- OPERATION PERFORMANCE --\u003e\n\u003ch2 class=\"section-title3\"\u003eOPERATION PERFORMANCE\u003c\/h2\u003e\n\u003cdiv class=\"flex-row\"\u003e\n    \n    \u003cdiv class=\"flex-item\"\u003e\n        \u003ch2 class=\"section-title4 title-center\"\u003eAFTER WIRING\u003c\/h2\u003e\n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 1\"\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"flex-item\"\u003e\n        \u003ch2 class=\"section-title4 title-center\"\u003eDISCONNECT THE WIRING\u003c\/h2\u003e\n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 2\"\u003e\n    \u003c\/div\u003e\n\n\u003c\/div\u003e\n\n\u003c!-- SPECIFICATIONS --\u003e\n\u003ch2 class=\"section-title3\"\u003eSPECIFICATIONS\u003c\/h2\u003e\n\u003cdiv class=\"parameters-table-wrapper\"\u003e\n\u003ctable class=\"parameters-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003eModel\u003c\/td\u003e\n\u003ctd\u003eUSS-MSV50027 \/ USS-MSV50027-G\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eU.S. Solid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003eSize\u003c\/td\u003e\n\u003ctd\u003e1-1\/2\"\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003eWiring Type\u003c\/td\u003e\n\u003ctd\u003e2 Wire Auto Return\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003eValve Material\u003c\/td\u003e\n\u003ctd\u003eUPVC\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003eEnclosure Rating\u003c\/td\u003e\n\u003ctd\u003eIP67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003eOperating Time\u003c\/td\u003e\n\u003ctd\u003e≤12 Seconds\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003eWorking Voltage\u003c\/td\u003e\n\u003ctd\u003e9 - 24V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003eMax Power\u003c\/td\u003e\n\u003ctd\u003e36 W\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003eMax Torque\u003c\/td\u003e\n\u003ctd\u003e15 N m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003eMax Medium Pressure\u003c\/td\u003e\n\u003ctd\u003e1.0 Mpa\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003eTemperature Range for Flow Medium\u003c\/td\u003e\n\u003ctd\u003e2°C to 55°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003eLife Expectancy\u003c\/td\u003e\n\u003ctd\u003e70,000 Cycles\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003eBore Type\u003c\/td\u003e\n\u003ctd\u003eFull\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003eThread Type\u003c\/td\u003e\n\u003ctd\u003eNPT\/G\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003eOperating State\u003c\/td\u003e\n\u003ctd\u003eNormally Closed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003eAmbient Temperature Range\u003c\/td\u003e\n\u003ctd\u003e-15°C to 50°C\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003eBall Seal\u003c\/td\u003e\n\u003ctd\u003ePTFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp class=\"section-description\"\u003e*To view the full table on mobile, please swipe left or right on the screen.\u003c\/p\u003e\n\n\u003c!-- CE CERTIFIED QUALITY \u0026 SAFETY --\u003e\n\u003ch2 class=\"section-title3\"\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/h2\u003e\n\u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/CE\/CE.jpg\"\u003e\n\u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/CE\/CE.jpg\"\u003e\n\n\u003c!-- FAQ --\u003e\n\u003ch2 class=\"section-title\"\u003eFAQ\u003c\/h2\u003e\n\n\u003cp class=\"faq\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\nThe motor's housing is rated at IP67 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\n\u003c\/p\u003e\n\n\u003cp class=\"faq\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\nIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\n\u003c\/p\u003e\n\n\u003cp class=\"faq\"\u003e\u003cb\u003e3. What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\nIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\n\u003c\/p\u003e\n\n\u003cp class=\"faq\"\u003e\u003cb\u003e4. Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\nYES. The motorized ball valve is made of lead-free Polyvinyl Chloride and is NSF certified.\n\u003c\/p\u003e\n\n\u003cp class=\"faq\"\u003e\u003cb\u003e5. For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\nTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\n\u003c\/p\u003e\n\n\u003cp class=\"faq\"\u003e\u003cb\u003e6. Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\nYes, our motorized ball valves are suitable for use with propane.\n\u003c\/p\u003e\n\n\u003c!-- WARNING --\u003e\n\u003ch2 class=\"section-title\"\u003eWARNING\u003c\/h2\u003e\n\n\u003cp class=\"section-description\"\u003e\n\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\n\u003c\/p\u003e\n\n\u003cp class=\"section-description\"\u003e\n\u003cb\u003e2.\u003c\/b\u003e The valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\n\u003c\/p\u003e\n\n\u003cp class=\"section-description\"\u003e\n\u003cb\u003e3.\u003c\/b\u003e Only Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\n\u003c\/p\u003e\n\n\u003cp class=\"section-description\"\u003e\n\u003cb\u003e4.\u003c\/b\u003e While the motorized ball valves have an IP67 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\n\u003c\/p\u003e\n\n\u003cp class=\"section-description\"\u003e\n\u003cb\u003e5.\u003c\/b\u003e These valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\n\u003c\/p\u003e\n\n\u003c!-- Valve Attributes --\u003e\n\u003ch2 class=\"section-title\"\u003eValve Attributes\u003c\/h2\u003e\n\n\u003cp class=\"section-description\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\nNormally Closed: The valve is closed when power is off and opens when power is on.\n\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\nNormally Open: The valve is open when power is off and closes when power is on.\n\u003c\/p\u003e\n\n\u003cp class=\"section-description\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\nFull Port: It has a wide internal passage, resulting in low water - flow resistance.\n\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\nStandard Port: Meets regular usage requirements.\n\u003c\/p\u003e\n\n\u003cp class=\"section-description\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\nThe valves have an ingress - protection rating of IP67. The 6 in IP67 represents complete dust - tightness. The 7 in IP67 indicates protection against water immersion up to 1 meter for 30 minutes. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\n\u003c\/p\u003e\n\u003cp\u003e\n  \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/IP67-UPVC.png\" alt=\"\"\u003e\n\u003c\/p\u003e\n\n\u003c!-- Valve Attributes --\u003e\n\u003ch2 class=\"section-title\"\u003eWIRING SCHEMATICS\u003c\/h2\u003e\n\u003cp\u003e\n  \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" alt=\"\"\u003e\n\u003c\/p\u003e\n\n\u003cp class=\"section-description\"\u003e\n\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\n\u003c\/p\u003e\n\n\u003c!-- FLOW DIRECTION --\u003e\n\u003ch2 class=\"section-title3\"\u003eFLOW DIRECTION\u003c\/h2\u003e\n\u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/jfesm50023-f.png\"\u003e\n\u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/jfesm50023-f.png\"\u003e\n\n\u003c!-- CHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS --\u003e\n\u003ch2 class=\"section-title3\"\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS \u0026amp; SAFETY\u003c\/h2\u003e\n\u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material.png\"\u003e\n\u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material-APP.png\"\u003e\n\n\u003cp class=\"section-description\"\u003e\nDownload user manual\n\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/Manual-50020-28.pdf\" target=\"_blank\"\u003ehere\u003c\/a\u003e.\n\u003c\/p\u003e","brand":"U.S. Solid","offers":[{"title":"NPT","offer_id":47615652954367,"sku":"JFMSV50027","price":344.89,"currency_code":"USD","in_stock":true},{"title":"G","offer_id":47615652987135,"sku":"JFMSV50027-G","price":342.89,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/1_3d0a8a54-5260-4ad2-8f96-5f11c719e9be.png?v=1778573764"},{"product_id":"2-3-way-upvc-motorized-ball-valve-l-type-9-24v-ac-dc-2-wire-auto-return-ip67-full-port-normally-closed-with-manual-reset","title":"2\" 3 Way UPVC Motorized Ball Valve, L Type, 9–24V AC\/DC, 2-Wire Auto Return, IP67 Full Port, Normally Closed with Manual Reset","description":"\u003cmeta charset=\"UTF-8\"\u003e\n\u003cmeta name=\"viewport\" content=\"width=device-width, initial-scale=1.0\"\u003e\n\n\u003cstyle\u003e\n.desktop-img { display: block; width: 100%; }\n.mobile-img { display: none; width: 100%; }\n\n.section-title,\n.section-title2,\n.section-title3,\n.section-title4 {\n    font-size: 22px;\n    line-height: 22px;\n    font-weight: bold;\n    margin: 15px 0 10px;\n    font-family: Arial;\n    color: black;\n}\n\n.title-center {\n    text-align: center;\n}\n\n.section-description {\n    font-size: 16px;\n    line-height: 26px;\n    margin: 5px 0;\n    font-family: Arial;\n    color: black;\n}\n\n.section-description2 {\n    font-size: 16px;\n    line-height: 26px;\n    margin: 0;\n    font-family: Arial;\n}\n\n.faq {\n    font-size: 16px;\n    line-height: 26px;\n    padding: 5px;\n    margin: 10px 0 5px;\n    font-family: Arial;\n    color: black;\n}\n\n.warning-title {\n    font-size: 22px;\n    text-align: left;\n    margin-top: 20px;\n    margin-bottom: 10px;\n    line-height: 26px;\n    color: black;\n    font-weight: bold;\n    font-family: Arial;\n  }\n\n  .flex-row {\n    display: flex;\n    gap: 20px;\n    margin: 20px 0;\n}\n\n.flex-item {\n    flex: 1;\n    min-width: 0;\n}\n\n.flex-item img {\n    width: 100%;\n    display: block;\n}\n\n.parameters-table-wrapper {\n    overflow-x: auto;\n    -webkit-overflow-scrolling: touch;\n}\n\n.parameters-table {\n    width: 100%;\n    min-width: 1000px;\n    border-collapse: collapse;\n    font-family: Arial;\n}\n\n.parameters-table th,\n.parameters-table td {\n    border-top: 1.2px solid #a6a6a6;\n    border-bottom: 1.2px solid #a6a6a6;\n    padding: 5px 2px;\n    text-align: left;\n    font-size: 16px;\n}\n\n.parameters-table th,\n.parameters-table .bg-gray {\n    background-color: #f2f2f2;\n    font-weight: bold;\n}\n\n.bg-gray {\n    color: black;\n    font-weight: bold;\n}\n\n@media (max-width: 768px) {\n    .desktop-img { display: none; }\n    .mobile-img { display: block; }\n    .flex-row {\n        flex-direction: column;\n        gap: 10px;\n    }\n    .parameters-table th,\n    .parameters-table td {\n        font-size: 14px;\n    }\n}\n\n@media (max-width: 480px) {\n    .parameters-table th,\n    .parameters-table td {\n        font-size: 12px;\n    }\n}\n\u003c\/style\u003e\n\n\u003c!-- Cover Image --\u003e\n\u003cp\u003e\n  \u003cimg class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" alt=\"\"\u003e\n  \u003cimg class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" alt=\"\"\u003e\n\u003c\/p\u003e\n\n\u003c!-- INTRODUCTION --\u003e\n\u003ch2 class=\"section-title\"\u003eINTRODUCTION\u003c\/h2\u003e\n\u003cp class=\"section-description\"\u003e\nMotorized ball valves are a vital piece of equipment in numerous applications. This model opens and closes in 3-5 seconds, and remains in its new position while expending almost no energy. This is a key difference between motorized ball valves and many solenoid valves. Most solenoid valves are energized continuously when in a new position, while motorized ball valves expend energy only when changing from open to close, or vice versa.\n\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\nThe 2 wire auto return model is perfect for situations where the valve needs to be closed in case of power loss. The valve can be energized to open, and left hooked up, with negligible energy used once fully opened. To close, simply shutoff power to the valve. This valve is convenient because it can be operated with a simple on off switch. When on, it will remain open, when turned off (or power is lost for some other reason) the valve automatically closes.\n\u003c\/p\u003e\n\n\u003c!-- FEATURES --\u003e\n\u003ch2 class=\"section-title\"\u003eFEATURES\u003c\/h2\u003e\n\u003cp\u003e\n  \u003cimg class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/1.png\" alt=\"\"\u003e\n  \u003cimg class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/1.png\" alt=\"\"\u003e\n\u003c\/p\u003e\n\n\u003c!-- MORE DETAILS --\u003e\n\u003ch2 class=\"section-title3\"\u003eMORE DETAILS\u003c\/h2\u003e\n\u003cdiv class=\"flex-row\"\u003e\n    \n    \u003cdiv class=\"flex-item\"\u003e\n        \u003ch2 class=\"section-title4 title-center\"\u003eMANUAL OVERRIDE\u003c\/h2\u003e\n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/jfesm50020-more1.png\" alt=\"\"\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"flex-item\"\u003e\n        \u003ch2 class=\"section-title4 title-center\"\u003eDETACHABLE DESIGN\u003c\/h2\u003e\n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/jfesm50023-more.jpg\" alt=\"\"\u003e\n    \u003c\/div\u003e\n\n\u003c\/div\u003e\n\n\u003c!-- APPLICATIONS --\u003e\n\u003ch2 class=\"section-title2\"\u003eAPPLICATIONS\u003c\/h2\u003e\n\u003cp\u003e\n  \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" alt=\"\"\u003e\n\u003c\/p\u003e\n\n\u003c!-- OPERATION PERFORMANCE --\u003e\n\u003ch2 class=\"section-title3\"\u003eOPERATION PERFORMANCE\u003c\/h2\u003e\n\u003cdiv class=\"flex-row\"\u003e\n    \n    \u003cdiv class=\"flex-item\"\u003e\n        \u003ch2 class=\"section-title4 title-center\"\u003eAFTER WIRING\u003c\/h2\u003e\n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 1\"\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"flex-item\"\u003e\n        \u003ch2 class=\"section-title4 title-center\"\u003eDISCONNECT THE WIRING\u003c\/h2\u003e\n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 2\"\u003e\n    \u003c\/div\u003e\n\n\u003c\/div\u003e\n\n\u003c!-- SPECIFICATIONS --\u003e\n\u003ch2 class=\"section-title3\"\u003eSPECIFICATIONS\u003c\/h2\u003e\n\u003cdiv class=\"parameters-table-wrapper\"\u003e\n\u003ctable class=\"parameters-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003eModel\u003c\/td\u003e\n\u003ctd\u003eUSS-MSV50028 \/ USS-MSV50028-G\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eU.S. Solid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003eSize\u003c\/td\u003e\n\u003ctd\u003e2\"\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003eWiring Type\u003c\/td\u003e\n\u003ctd\u003e2 Wire Auto Return\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003eValve Material\u003c\/td\u003e\n\u003ctd\u003eUPVC\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003eEnclosure Rating\u003c\/td\u003e\n\u003ctd\u003eIP67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003eOperating Time\u003c\/td\u003e\n\u003ctd\u003e≤12 Seconds\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003eWorking Voltage\u003c\/td\u003e\n\u003ctd\u003e9 - 24V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003eMax Power\u003c\/td\u003e\n\u003ctd\u003e36 W\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003eMax Torque\u003c\/td\u003e\n\u003ctd\u003e15 N m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003eMax Medium Pressure\u003c\/td\u003e\n\u003ctd\u003e1.0 Mpa\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003eTemperature Range for Flow Medium\u003c\/td\u003e\n\u003ctd\u003e2°C to 55°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003eLife Expectancy\u003c\/td\u003e\n\u003ctd\u003e70,000 Cycles\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003eBore Type\u003c\/td\u003e\n\u003ctd\u003eFull\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003eThread Type\u003c\/td\u003e\n\u003ctd\u003eNPT\/G\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003eOperating State\u003c\/td\u003e\n\u003ctd\u003eNormally Closed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003eAmbient Temperature Range\u003c\/td\u003e\n\u003ctd\u003e-15°C to 50°C\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003eBall Seal\u003c\/td\u003e\n\u003ctd\u003ePTFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp class=\"section-description\"\u003e*To view the full table on mobile, please swipe left or right on the screen.\u003c\/p\u003e\n\n\u003c!-- CE CERTIFIED QUALITY \u0026 SAFETY --\u003e\n\u003ch2 class=\"section-title3\"\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/h2\u003e\n\u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/CE\/CE.jpg\"\u003e\n\u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/CE\/CE.jpg\"\u003e\n\n\u003c!-- FAQ --\u003e\n\u003ch2 class=\"section-title\"\u003eFAQ\u003c\/h2\u003e\n\n\u003cp class=\"faq\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\nThe motor's housing is rated at IP67 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\n\u003c\/p\u003e\n\n\u003cp class=\"faq\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\nIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\n\u003c\/p\u003e\n\n\u003cp class=\"faq\"\u003e\u003cb\u003e3. What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\nIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\n\u003c\/p\u003e\n\n\u003cp class=\"faq\"\u003e\u003cb\u003e4. Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\nYES. The motorized ball valve is made of lead-free Polyvinyl Chloride and is NSF certified.\n\u003c\/p\u003e\n\n\u003cp class=\"faq\"\u003e\u003cb\u003e5. For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\nTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\n\u003c\/p\u003e\n\n\u003cp class=\"faq\"\u003e\u003cb\u003e6. Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\nYes, our motorized ball valves are suitable for use with propane.\n\u003c\/p\u003e\n\n\u003c!-- WARNING --\u003e\n\u003ch2 class=\"section-title\"\u003eWARNING\u003c\/h2\u003e\n\n\u003cp class=\"section-description\"\u003e\n\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\n\u003c\/p\u003e\n\n\u003cp class=\"section-description\"\u003e\n\u003cb\u003e2.\u003c\/b\u003e The valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\n\u003c\/p\u003e\n\n\u003cp class=\"section-description\"\u003e\n\u003cb\u003e3.\u003c\/b\u003e Only Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\n\u003c\/p\u003e\n\n\u003cp class=\"section-description\"\u003e\n\u003cb\u003e4.\u003c\/b\u003e While the motorized ball valves have an IP67 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\n\u003c\/p\u003e\n\n\u003cp class=\"section-description\"\u003e\n\u003cb\u003e5.\u003c\/b\u003e These valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\n\u003c\/p\u003e\n\n\u003c!-- Valve Attributes --\u003e\n\u003ch2 class=\"section-title\"\u003eValve Attributes\u003c\/h2\u003e\n\n\u003cp class=\"section-description\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\nNormally Closed: The valve is closed when power is off and opens when power is on.\n\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\nNormally Open: The valve is open when power is off and closes when power is on.\n\u003c\/p\u003e\n\n\u003cp class=\"section-description\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\nFull Port: It has a wide internal passage, resulting in low water - flow resistance.\n\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\nStandard Port: Meets regular usage requirements.\n\u003c\/p\u003e\n\n\u003cp class=\"section-description\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\nThe valves have an ingress - protection rating of IP67. The 6 in IP67 represents complete dust - tightness. The 7 in IP67 indicates protection against water immersion up to 1 meter for 30 minutes. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\n\u003c\/p\u003e\n\u003cp\u003e\n  \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/IP67-UPVC.png\" alt=\"\"\u003e\n\u003c\/p\u003e\n\n\u003c!-- Valve Attributes --\u003e\n\u003ch2 class=\"section-title\"\u003eWIRING SCHEMATICS\u003c\/h2\u003e\n\u003cp\u003e\n  \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" alt=\"\"\u003e\n\u003c\/p\u003e\n\n\u003cp class=\"section-description\"\u003e\n\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\n\u003c\/p\u003e\n\n\u003c!-- FLOW DIRECTION --\u003e\n\u003ch2 class=\"section-title3\"\u003eFLOW DIRECTION\u003c\/h2\u003e\n\u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/jfesm50023-f.png\"\u003e\n\u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/jfesm50023-f.png\"\u003e\n\n\u003c!-- CHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS --\u003e\n\u003ch2 class=\"section-title3\"\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS \u0026amp; SAFETY\u003c\/h2\u003e\n\u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material.png\"\u003e\n\u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material-APP.png\"\u003e\n\n\u003cp class=\"section-description\"\u003e\nDownload user manual\n\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/Manual-50020-28.pdf\" target=\"_blank\"\u003ehere\u003c\/a\u003e.\n\u003c\/p\u003e","brand":"U.S. Solid","offers":[{"title":"NPT","offer_id":47615659376895,"sku":"JFMSV50028","price":354.89,"currency_code":"USD","in_stock":true},{"title":"G","offer_id":47615659409663,"sku":"JFMSV50028-G","price":353.89,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/1_a1e1c429-857b-447d-afc4-d7e078dd4ec8.png?v=1778573764"},{"product_id":"1-2-upvc-motorized-ball-valve-85-265v-ac-plastic-electrical-ball-valve-with-full-port-2-wire-auto-return-normally-open","title":"1\/2\" UPVC Motorized Ball Valve - 85-265V AC Plastic Electrical Ball Valve with Full Port, 2 Wire Auto Return, Normally Open","description":"\u003cbody\u003e \n\n\n    \u003cstyle\u003e\n        @media only screen and (max-width: 600px) {\n        }\n    \u003c\/style\u003e\n\n\n    \u003cdiv class=\"desktop-only\"\u003e\n        \n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; line-height: 26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 10px; color: black; font-family: Arial;\"\u003eMotorized ball valves are a vital piece of equipment in numerous applications. This model opens and closes in 6-8 seconds, and remains in its new position while expending almost no energy. This is a key difference between motorized ball valves and many solenoid valves. Most solenoid valves are energized continuously when in a new position, while motorized ball valves expend energy only when changing from open to close, or vice versa.\u003cbr\u003eThe 2 wire auto return model is perfect for situations where the valve needs to be closed in case of power loss. The valve can be energized to open, and left hooked up, with negligible energy used once fully opened. To close, simply shutoff power to the valve. This valve is convenient because it can be operated with a simple on off switch. When on, it will remain open, when turned off (or power is lost for some other reason) the valve automatically closes.\u003c\/p\u003e\n        \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/1.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n             \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n    \u003ctable style=\"border-collapse: collapse;\n                  border: 0px;\n                  width: 100%;\n                  font-family: Arial;\n                  overflow-x: auto;\n                  background-color: #FFFFFF;\"\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"width: 100%;text-align: left;\n                       padding: 0px;\n                       font-size: 16px;\n                       border: 0;\n                       background-color: #FFFFFF;\"\u003e\n                \u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 1\/2\" style=\"width: 100%;height: 100%;\"\u003e\n            \u003c\/td\u003e\n            \u003ctd style=\"width: 100%;text-align: left;\n                       padding: 0px;\n                       font-size: 16px;\n                       border: 0;\n                       background-color: #FFFFFF;\"\u003e\n                \u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 1\/2\" style=\"width: 100%;height: 100%;\"\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/table\u003e\n\u003c\/div\u003e\n          \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e \n \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV00501\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eU.S. Solid\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1\/2\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e2 Wire Auto Return\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eUPVC\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e6 - 8 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eAC 85-265V\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e10 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e2 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1°C to 55°C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e50,000 to 80,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eFull\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\/G\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNormally Open\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1°C to 50°C\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eIP65\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/CE.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP65 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYES. The motorized ball valve is made of lead-free UPVC.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n    \u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP65 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP65. The first digit 6 indicates complete dust - tightness. The second digit 5 means protection against water jets from any direction. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/valve%20model.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/JFMSV-User-manual.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n    \u003c\/div\u003e\n    \u003cdiv class=\"mobile-only\"\u003e\n       \n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; line-height:26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 0px; color: black; font-family: Arial;\"\u003eMotorized ball valves are a vital piece of equipment in numerous applications. This model opens and closes in 6-8 seconds, and remains in its new position while expending almost no energy. This is a key difference between motorized ball valves and many solenoid valves. Most solenoid valves are energized continuously when in a new position, while motorized ball valves expend energy only when changing from open to close, or vice versa.\u003cbr\u003eThe 2 wire auto return model is perfect for situations where the valve needs to be Open in case of power loss. The valve can be energized to open, and left hooked up, with negligible energy used once fully opened. To close, simply shutoff power to the valve. This valve is convenient because it can be operated with a simple on off switch. When on, it will remain open, when turned off (or power is lost for some other reason) the valve automatically closes.\u003c\/p\u003e\n            \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/1.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-bottom:10px; margin-top:20px; color: black;\"\u003e\u003cstrong\u003eAPPLICATION\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n    \u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 1\/2\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n    \u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 1\/2\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n\u003c\/div\u003e\n      \u003cp style=\"font-size: 16px; text-align: left; margin-bottom:10px; margin-top:20px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV00501\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eU.S. Solid\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1\/2\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e2 Wire Auto Return\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eUPVC\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e6 - 8 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eAC 85-265V\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e10 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e2 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1°C to 55°C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e50,000 to 80,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eFull\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\/G\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNormally Open\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1°C to 50°C\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eIP65\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/CE.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP65 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYES. The motorized ball valve is made of lead-free UPVC.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n    \u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP65 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP65. The first digit 6 indicates complete dust - tightness. The second digit 5 means protection against water jets from any direction. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/valve%20model.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material-APP.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/JFMSV-User-manual.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n    \u003cscript\u003e\n\n        \n        const isMobile = window.matchMedia(\"only screen and (max-width: 600px)\").matches;\n        const desktopContent = document.querySelector('.desktop-only');\n        const mobileContent = document.querySelector('.mobile-only');\n\n        if (isMobile) {\n           \n            console.log('');\n           \n            desktopContent.style.display = 'none';\n            mobileContent.style.display = 'block';\n        } else {\n           \n            console.log('');            \n            \n            desktopContent.style.display = 'block';\n            mobileContent.style.display = 'none';\n        }\n    \u003c\/script\u003e\n\n\n\n\u003c\/body\u003e","brand":"U.S. Solid","offers":[{"title":"NPT","offer_id":47642249953535,"sku":"JFMSV00501","price":41.49,"currency_code":"USD","in_stock":true},{"title":"G","offer_id":47642249986303,"sku":"JFMSV00501-G","price":39.49,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/JFMSV00094_1.jpg?v=1765247842"},{"product_id":"3-4-upvc-motorized-ball-valve-85-265v-ac-plastic-electrical-ball-valve-with-full-port-2-wire-auto-return-normally-open","title":"3\/4\" UPVC Motorized Ball Valve - 85-265V AC Plastic Electrical Ball Valve with Full Port, 2 Wire Auto Return, Normally Open","description":"\u003cbody\u003e \n\n\n    \u003cstyle\u003e\n        @media only screen and (max-width: 600px) {\n        }\n    \u003c\/style\u003e\n\n\n    \u003cdiv class=\"desktop-only\"\u003e\n        \n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; line-height: 26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 10px; color: black; font-family: Arial;\"\u003eMotorized ball valves are a vital piece of equipment in numerous applications. This model opens and closes in 6-8 seconds, and remains in its new position while expending almost no energy. This is a key difference between motorized ball valves and many solenoid valves. Most solenoid valves are energized continuously when in a new position, while motorized ball valves expend energy only when changing from open to close, or vice versa.\u003cbr\u003eThe 2 wire auto return model is perfect for situations where the valve needs to be closed in case of power loss. The valve can be energized to open, and left hooked up, with negligible energy used once fully opened. To close, simply shutoff power to the valve. This valve is convenient because it can be operated with a simple on off switch. When on, it will remain open, when turned off (or power is lost for some other reason) the valve automatically closes.\u003c\/p\u003e\n        \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/1.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n             \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n    \u003ctable style=\"border-collapse: collapse;\n                  border: 0px;\n                  width: 100%;\n                  font-family: Arial;\n                  overflow-x: auto;\n                  background-color: #FFFFFF;\"\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"width: 100%;text-align: left;\n                       padding: 0px;\n                       font-size: 16px;\n                       border: 0;\n                       background-color: #FFFFFF;\"\u003e\n                \u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 3\/4\" style=\"width: 100%;height: 100%;\"\u003e\n            \u003c\/td\u003e\n            \u003ctd style=\"width: 100%;text-align: left;\n                       padding: 0px;\n                       font-size: 16px;\n                       border: 0;\n                       background-color: #FFFFFF;\"\u003e\n                \u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 3\/4\" style=\"width: 100%;height: 100%;\"\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/table\u003e\n\u003c\/div\u003e\n          \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e \n \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV00502\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eU.S. Solid\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e3\/4\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e2 Wire Auto Return\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eUPVC\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e6 - 8 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eAC 85-265V\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e10 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e2 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1°C to 55°C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e50,000 to 80,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eFull\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\/G\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNormally Open\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1°C to 50°C\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eIP65\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/CE.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP65 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYES. The motorized ball valve is made of lead-free UPVC.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n    \u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP65 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP65. The first digit 6 indicates complete dust - tightness. The second digit 5 means protection against water jets from any direction. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/valve%20model.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/JFMSV-User-manual.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n    \u003c\/div\u003e\n    \u003cdiv class=\"mobile-only\"\u003e\n        \n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; line-height:26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 0px; color: black; font-family: Arial;\"\u003eMotorized ball valves are a vital piece of equipment in numerous applications. This model opens and closes in 6-8 seconds, and remains in its new position while expending almost no energy. This is a key difference between motorized ball valves and many solenoid valves. Most solenoid valves are energized continuously when in a new position, while motorized ball valves expend energy only when changing from open to close, or vice versa.\u003cbr\u003eThe 2 wire auto return model is perfect for situations where the valve needs to be Open in case of power loss. The valve can be energized to open, and left hooked up, with negligible energy used once fully opened. To close, simply shutoff power to the valve. This valve is convenient because it can be operated with a simple on off switch. When on, it will remain open, when turned off (or power is lost for some other reason) the valve automatically closes.\u003c\/p\u003e\n            \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/1.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-bottom:10px; margin-top:20px; color: black;\"\u003e\u003cstrong\u003eAPPLICATION\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n    \u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 3\/4\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n    \u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 3\/4\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n\u003c\/div\u003e\n      \u003cp style=\"font-size: 16px; text-align: left; margin-bottom:10px; margin-top:20px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV00502\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eU.S. Solid\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e3\/4\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e2 Wire Auto Return\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eUPVC\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e6 - 8 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eAC 85-265V\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e10 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e2 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1°C to 55°C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e50,000 to 80,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eFull\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\/G\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNormally Open\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1°C to 50°C\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eIP65\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/CE.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP65 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYES. The motorized ball valve is made of lead-free UPVC.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n    \u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP65 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP65. The first digit 6 indicates complete dust - tightness. The second digit 5 means protection against water jets from any direction. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/valve%20model.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material-APP.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/JFMSV-User-manual.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n    \u003cscript\u003e\n\n        const isMobile = window.matchMedia(\"only screen and (max-width: 600px)\").matches;\n        const desktopContent = document.querySelector('.desktop-only');\n        const mobileContent = document.querySelector('.mobile-only');\n\n        if (isMobile) {\n            \n            console.log('');\n            \n            desktopContent.style.display = 'none';\n            mobileContent.style.display = 'block';\n        } else {\n            \n            console.log('');            \n            \n            desktopContent.style.display = 'block';\n            mobileContent.style.display = 'none';\n        }\n    \u003c\/script\u003e\n\n\n\n\u003c\/body\u003e","brand":"U.S. Solid","offers":[{"title":"NPT","offer_id":47642250182911,"sku":"JFMSV00502","price":43.46,"currency_code":"USD","in_stock":true},{"title":"G","offer_id":47642250215679,"sku":"JFMSV00502-G","price":41.49,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/JFMSV00095_1.jpg?v=1765247893"},{"product_id":"1-upvc-motorized-ball-valve-85-265v-ac-plastic-electrical-ball-valve-with-full-port-2-wire-auto-return-normally-open","title":"1\" UPVC Motorized Ball Valve - 85-265V AC Plastic Electrical Ball Valve with Full Port, 2 Wire Auto Return, Normally Open","description":"\u003cbody\u003e \n\n\n    \u003cstyle\u003e\n        @media only screen and (max-width: 600px) {\n        }\n    \u003c\/style\u003e\n\n\n    \u003cdiv class=\"desktop-only\"\u003e\n       \n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; line-height: 26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 10px; color: black; font-family: Arial;\"\u003eMotorized ball valves are a vital piece of equipment in numerous applications. This model opens and closes in 6-8 seconds, and remains in its new position while expending almost no energy. This is a key difference between motorized ball valves and many solenoid valves. Most solenoid valves are energized continuously when in a new position, while motorized ball valves expend energy only when changing from open to close, or vice versa.\u003cbr\u003eThe 2 wire auto return model is perfect for situations where the valve needs to be closed in case of power loss. The valve can be energized to open, and left hooked up, with negligible energy used once fully opened. To close, simply shutoff power to the valve. This valve is convenient because it can be operated with a simple on off switch. When on, it will remain open, when turned off (or power is lost for some other reason) the valve automatically closes.\u003c\/p\u003e\n        \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/1.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n             \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n    \u003ctable style=\"border-collapse: collapse;\n                  border: 0px;\n                  width: 100%;\n                  font-family: Arial;\n                  overflow-x: auto;\n                  background-color: #FFFFFF;\"\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"width: 100%;text-align: left;\n                       padding: 0px;\n                       font-size: 16px;\n                       border: 0;\n                       background-color: #FFFFFF;\"\u003e\n                \u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 1\" style=\"width: 100%;height: 100%;\"\u003e\n            \u003c\/td\u003e\n            \u003ctd style=\"width: 100%;text-align: left;\n                       padding: 0px;\n                       font-size: 16px;\n                       border: 0;\n                       background-color: #FFFFFF;\"\u003e\n                \u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 1\" style=\"width: 100%;height: 100%;\"\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/table\u003e\n\u003c\/div\u003e\n          \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e \n \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV00503\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eU.S. Solid\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e2 Wire Auto Return\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eUPVC\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e6 - 8 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eAC 85-265V\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e10 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e2 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1°C to 55°C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e50,000 to 80,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eFull\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\/G\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNormally Open\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1°C to 50°C\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eIP65\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/CE.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP65 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYES. The motorized ball valve is made of lead-free UPVC.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n    \u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP65 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP65. The first digit 6 indicates complete dust - tightness. The second digit 5 means protection against water jets from any direction. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/valve%20model.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/JFMSV-User-manual.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n    \u003c\/div\u003e\n    \u003cdiv class=\"mobile-only\"\u003e\n        \u003c!--  --\u003e\n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; line-height:26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 0px; color: black; font-family: Arial;\"\u003eMotorized ball valves are a vital piece of equipment in numerous applications. This model opens and closes in 6-8 seconds, and remains in its new position while expending almost no energy. This is a key difference between motorized ball valves and many solenoid valves. Most solenoid valves are energized continuously when in a new position, while motorized ball valves expend energy only when changing from open to close, or vice versa.\u003cbr\u003eThe 2 wire auto return model is perfect for situations where the valve needs to be Open in case of power loss. The valve can be energized to open, and left hooked up, with negligible energy used once fully opened. To close, simply shutoff power to the valve. This valve is convenient because it can be operated with a simple on off switch. When on, it will remain open, when turned off (or power is lost for some other reason) the valve automatically closes.\u003c\/p\u003e\n            \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/1.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-bottom:10px; margin-top:20px; color: black;\"\u003e\u003cstrong\u003eAPPLICATION\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n    \u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 1\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n    \u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 1\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n\u003c\/div\u003e\n      \u003cp style=\"font-size: 16px; text-align: left; margin-bottom:10px; margin-top:20px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV00503\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eU.S. Solid\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e2 Wire Auto Return\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eUPVC\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e6 - 8 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eAC 85-265V\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e10 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e2 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1°C to 55°C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e50,000 to 80,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eFull\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\/G\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNormally Open\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1°C to 50°C\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eIP65\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/CE.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP65 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYES. The motorized ball valve is made of lead-free UPVC.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n    \u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP65 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP65. The first digit 6 indicates complete dust - tightness. The second digit 5 means protection against water jets from any direction. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/valve%20model.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material-APP.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/JFMSV-User-manual.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n    \u003cscript\u003e\n\n        \/\/ (User Agent)\n        const isMobile = window.matchMedia(\"only screen and (max-width: 600px)\").matches;\n        const desktopContent = document.querySelector('.desktop-only');\n        const mobileContent = document.querySelector('.mobile-only');\n\n        if (isMobile) {\n            \/\/ \n            console.log('');\n            \/\/ ，\n            desktopContent.style.display = 'none';\n            mobileContent.style.display = 'block';\n        } else {\n            \/\/ \n            console.log('');            \n            \/\/ ，\n            desktopContent.style.display = 'block';\n            mobileContent.style.display = 'none';\n        }\n    \u003c\/script\u003e\n\n\n\n\u003c\/body\u003e","brand":"U.S. Solid","offers":[{"title":"NPT","offer_id":47642253361407,"sku":"JFMSV00503","price":47.49,"currency_code":"USD","in_stock":true},{"title":"G","offer_id":47642253394175,"sku":"JFMSV00503-G","price":45.49,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/JFMSV00096_1.jpg?v=1765247933"},{"product_id":"1-1-4-double-union-upvc-motorized-ball-valve-dc-24v-5-wire-with-signal-feedback-auto-return-normally-closed-manual-override-epdm-seal","title":"1-1\/4\" Double Union UPVC Motorized Ball Valve - DC 24V, 5-Wire with Signal Feedback, Auto Return, Normally Closed \u0026 Manual Override, EPDM Seal","description":"\u003cbody\u003e\n    \u003cmeta charset=\"UTF-8\"\u003e\n    \u003cmeta name=\"viewport\" content=\"width=device-width, initial-scale=1.0\"\u003e\n    \u003ctitle\u003eResponsive Page with Multiple Modules\u003c\/title\u003e\n    \u003cstyle\u003e\n\n        .desktop-img {\n            display: block;\n        }\n        .mobile-img {\n            display: none;\n        }\n\n        .section-title {\n            font-size: 22px;\n            line-height: 22px;\n            font-weight: bold;\n            margin: 15px 0 5px;\n            font-family: Arial;\n        }\n\n        .section-title2 {\n            font-size: 22px;\n            line-height: 22px;\n            font-weight: bold;\n            margin: 15px 0 3px;\n            font-family: Arial;\n        }\n\n        .section-title3 {\n            font-size: 22px;\n            line-height: 22px;\n            font-weight: bold;\n            margin: 15px 0 10px;\n            font-family: Arial;\n        }\n\n        .section-description {\n            font-size: 16px;\n            line-height: 26px;\n            margin-top: 0px;\n            margin-bottom: 5px;\n            font-family: Arial;\n        }\n\n        .faq {\n            font-size: 16px;\n            margin: 0;\n            line-height: 26px;\n            background-color: #f2f2f2;\n            padding: 5px;\n        }\n\n        .section-description2 {\n            font-size: 16px;\n            line-height: 26px;\n            margin: 0px;\n            font-family: Arial;\n        }\n\n        .parameters-table-wrapper {\n            overflow-x: auto;\n            -webkit-overflow-scrolling: touch;\n            margin-top: 0px;\n        }\n\n        .parameters-table {\n            width: 100%;\n            min-width: 1000px;\n            border-collapse: collapse;\n            margin-top: 0px;\n        }\n\n        .parameters-table th, .parameters-table td {\n            border-top: 1.2px solid #a6a6a6;\n            border-bottom: 1.2px solid #a6a6a6;\n            border-left: none;\n            border-right: none;\n            padding: 5px 2px;\n            text-align: left;\n            font-size: 16px;\n            line-height: 16px;\n        }\n\n        .parameters-table th {\n            background-color: #f2f2f2;\n            color: #2c2c2c;\n            font-weight: bold;\n        }\n\n        .parameters-table .bg-gray {\n            background-color: #f2f2f2;\n        }\n\n        .options-table-wrapper {\n            overflow-x: auto;\n            -webkit-overflow-scrolling: touch;\n            margin-top: 0px;\n        }\n\n        .options-table {\n            width: 100%;\n            min-width: 1000px;\n            border-collapse: collapse;\n            margin-top: 0px;\n            box-shadow: 0 6px 25px rgba(0, 0, 0, 0.1);\n        }\n\n        .options-table th, .options-table td {\n            border: 2px solid #000;\n            padding: 5px 2px;\n            text-align: center;\n            font-size: 16px;\n            line-height: 16px;\n        }\n\n        .options-table th {\n            background-color: #f2f2f2;\n            color: #2c2c2c;\n            font-weight: bold;\n        }\n\n        .parameters-table2 {\n            width: 100%;\n            min-width: 1000px;\n            border-collapse: collapse;\n            margin-top: 0px;\n        }\n\n        .parameters-table2 th, .parameters-table2 td {\n            border-top: 1.2px solid #a6a6a6;\n            border-bottom: 1.2px solid #a6a6a6;\n            border-left: none;\n            border-right: none;\n            padding: 5px 2px;\n            text-align: center;\n            font-size: 16px;\n            line-height: 16px;\n        }\n\n        .parameters-table2 th {\n            background-color: #f2f2f2;\n            color: #2c2c2c;\n            font-weight: bold;\n        }\n\n        .parameters-table2 .bg-gray {\n            background-color: #f2f2f2;\n        }\n\n        .options-table-wrapper2 {\n            overflow-x: auto;\n            -webkit-overflow-scrolling: touch;\n            margin-top: 0px;\n        }\n\n        .instruction-container {\n            display: flex;\n            justify-content: space-between;\n            align-items: flex-start;\n            gap: 10px;\n            margin-bottom: 0px;\n        }\n\n        .img-container {\n            width: 35%;\n            display: flex;\n            justify-content: center;\n        }\n\n        .text-container {\n            width: 65%;\n            font-size: 16px;\n            font-family: Arial;\n        }\n\n        .instruction-container2 {\n            display: flex;\n            justify-content: space-between;\n            align-items: flex-start;\n            gap: 10px;\n            margin-bottom: 0px;\n        }\n\n        .img-container2 {\n            width: 50%;\n            display: flex;\n            justify-content: center;\n        }\n\n        .text-container2 {\n            width: 50%;\n            display: flex;\n            justify-content: center;\n        }\n\n        @media (max-width: 768px) {\n            .parameters-table th, .parameters-table td {\n                font-size: 14px;\n                padding: 8px 4px;\n            }\n\n            .options-table th, .options-table td {\n                font-size: 14px;\n                padding: 8px 4px;\n            }\n\n            .parameters-table-wrapper {\n                overflow-x: auto;\n            }\n\n            .parameters-table2 th, .parameters-table2 td {\n                font-size: 14px;\n                padding: 8px 4px;\n            }\n\n            .parameters-table-wrapper2 {\n                overflow-x: auto;\n            }\n\n            .desktop-img {\n                display: none;\n            }\n\n            .mobile-img {\n                display: block;\n            }\n\n            .instruction-container {\n                flex-direction: column;\n                align-items: center;\n            }\n\n            .img-container, .text-container {\n                width: 100%;\n                margin-bottom: 0px;\n            }\n\n            .instruction-container2 {\n                flex-direction: column;\n                align-items: center;\n            }\n\n            .img-container2, .text-container2 {\n                width: 100%;\n                margin-bottom: 0px;\n            }\n        }\n\n        @media (max-width: 480px) {\n            .parameters-table th, .parameters-table td {\n                font-size: 12px;\n                padding: 6px 3px;\n            }\n\n            .options-table th, .options-table td {\n                font-size: 12px;\n            }\n\n            .parameters-table-wrapper {\n                overflow-x: auto;\n            }\n\n            .parameters-table2 th, .parameters-table2 td {\n                font-size: 12px;\n                padding: 6px 3px;\n            }\n\n            .parameters-table-wrapper2 {\n                overflow-x: auto;\n            }\n\n            .desktop-img {\n                display: none;\n            }\n\n            .mobile-img {\n                display: block;\n            }\n\n            .instruction-container {\n                flex-direction: column;\n            }\n\n            .instruction-container2 {\n                flex-direction: column;\n            }\n        }\n\n    \u003c\/style\u003e\n\n\u003c!-- Background --\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/UPVC2\/b.jpg\" class=\"desktop-img\" alt=\"Desktop Image 1\"\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/UPVC2\/b-p.jpg\" class=\"mobile-img\" alt=\"Mobile Image 1\"\u003e\n\u003c!-- Introduction - 5-Wire Auto Return \/ With Signal Feedback --\u003e\n\u003cdiv\u003e\n    \u003ch2 class=\"section-title\"\u003eIntroduction\u003c\/h2\u003e\n    \u003cp class=\"section-description\"\u003e\n        Our electric UPVC ball valve series has been upgraded to include three larger sizes: 1-1\/4\", 1-1\/2\", and 2\". These larger valves feature a unique \u003cstrong\u003e\u003cu\u003eUS standard socket end \u0026amp; double union connection\u003c\/u\u003e\u003c\/strong\u003e—enabling exceptional ease of installation and maintenance with a simple solvent cement bond, \u003cstrong\u003e\u003cu\u003eunlike\u003c\/u\u003e\u003c\/strong\u003e threaded NPT or G connections. For other connection standards, please contact our customer service.\u003cbr\u003eThese valves feature a \u003cstrong\u003e\u003cu\u003e5-wire auto-return configuration with signal feedback\u003c\/u\u003e\u003c\/strong\u003e and remain in a normally-closed position. They use two wires for power supply and three dedicated wires for signal feedback only, providing open\/closed position signaling to your control system. For safety, they automatically close if power is lost. A manual override is also included for use during power outages. All valves have EPDM seals for reliable performance.\n    \u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- Applications--\u003e\n     \u003ch2 class=\"section-title2\"\u003eApplications\u003c\/h2\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/UPVC2\/a.jpg\" class=\"desktop-img\" alt=\"Desktop Image 1\"\u003e\n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/UPVC2\/a-p.jpg\" class=\"mobile-img\" alt=\"Desktop Image 2\"\u003e\n\u003c!-- Features - 5-Wire Auto Return with Signal Feedback --\u003e\n\u003cdiv\u003e\n    \u003ch2 class=\"section-title\"\u003eFeatures\u003c\/h2\u003e\n    \u003cul class=\"section-description2\"\u003e\n        \u003cli\u003e\n\u003cstrong\u003eUnion \u0026amp; Socket End:\u003c\/strong\u003e Different from standard NPT\/G threaded connections, it uses socket-gluing for sealing and integrates threaded structures, balancing connection stability with quick disassembly and maintenance needs.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eManual Function:\u003c\/strong\u003e Comes with a hex wrench as standard; allows manual valve opening and closing during power outages. \"O\"=Open, \"S\"=Close.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eIndicator Window:\u003c\/strong\u003e Built-in engraved marks directly show the valve's open\/closed status. External arrow pointing to \"0\" means fully closed; pointing to \"90\" means fully open.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003ePremium Material:\u003c\/strong\u003e Valve body made of UPVC with EPDM seals, meeting general operating requirements.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003e5-Wire Auto Return with Signal Feedback:\u003c\/strong\u003e Uses two wires for power supply and three dedicated wires for signal feedback. The valve remains normally closed, automatically closes when power is lost, and provides open\/closed position feedback to a control or monitoring system.\u003c\/li\u003e\n    \u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/UPVC2\/5-Return.jpg\" class=\"desktop-img\" alt=\"Desktop Image 1\"\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/UPVC2\/5-Return-p.jpg\" class=\"mobile-img\" alt=\"Desktop Image 2\"\u003e\n\u003c!-- User Manual --\u003e\n\u003cdiv\u003e\n    \u003ch2 class=\"section-title\"\u003eUser Manual\u003c\/h2\u003e\n    \u003cp class=\"section-description\"\u003e\n        To learn how to use this product, please refer to the \u003ca href=\"https:\/\/file.ussolid.com\/content\/JFMSV\/Manual-%20USS-UPVC.pdf\" target=\"_blank\"\u003euser manual\u003c\/a\u003e.\n    \u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- Technical Data --\u003e\n    \u003ch2 class=\"section-title3\"\u003eTechnical Data\u003c\/h2\u003e \n    \u003cdiv class=\"parameters-table-wrapper\"\u003e\n        \u003ctable class=\"parameters-table\"\u003e\n            \u003ctbody\u003e \n                \u003ctr\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003ePort Size\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003e1 1\/4\"\u003c\/td\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003eUSS-MSV470\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003ePort\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003e2 Way\u003c\/td\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eThread\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003eNo Thread\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eConnection\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003eUnion \u0026amp; Socket End\u003c\/td\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eMax Power\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003e36W\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eSocket Inside Diameter\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003e42.2mm (US Standard)\u003c\/td\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eWith Hex Wrench\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003eYes\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eWiring\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003e5-Wire (2-Wire Auto Return + Signal Feedback)\u003c\/td\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eManual Function\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003eYes\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eSignal feedback function\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003eYes\u003c\/td\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eIndicator Window\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003eYes\u003c\/td\u003e\n                \u003c\/tr\u003e\n\n                \u003ctr\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eBody Material\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003eUPVC\u003c\/td\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eNormal Position\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003eNormally Closed\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eSeal Material\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003eEPDM\u003c\/td\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eTemp Range (Medium)\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003e33.8℉ to 104℉\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eWorking Voltage\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003eDC 24V\u003c\/td\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eClose\/Open Time\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003e10-12s\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eMax Torque\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003e20 N·m\u003c\/td\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eMax. Pressure\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003e232 psi\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eLife Expectancy\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003e20,000 Cycles\u003c\/td\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eIP Rating\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003eIP65\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003ePackage Size\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003e9.1\"x7.1\"x4.7\"\u003c\/td\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eGross Weight\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003e3.31 lb\u003c\/td\u003e\n                \u003c\/tr\u003e \n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n    \u003cp class=\"section-description\"\u003e*To view the full table on mobile, please swipe left or right on the screen.\u003c\/p\u003e\n\u003c!-- Wiring - 5-Wire Auto Return with Signal Feedback --\u003e\n\u003ch2 class=\"section-title\"\u003e5-Wire (2-Wire Auto Return + Signal Feedback)\u003c\/h2\u003e\n\u003cdiv class=\"instruction-container\"\u003e\n    \u003cdiv class=\"img-container\"\u003e\n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Wire\/return.jpg\" alt=\"\" style=\"width: 100%; height: auto;\"\u003e\n    \u003c\/div\u003e\n    \u003cdiv class=\"text-container\"\u003e\n        \u003cp class=\"section-description\"\u003e\n            This model uses a 5-wire wiring method that combines 2-wire auto-return control with signal feedback. It includes two wires for power supply and three wires for open\/closed position feedback. The valve is normally closed by default: it opens when powered and automatically returns to the closed position when power is lost or disconnected.\n        \u003c\/p\u003e\n        \u003cul class=\"section-description2\"\u003e\n            \u003cli\u003eConnect the power and signal feedback wires according to the wiring diagram.\u003c\/li\u003e\n            \u003cli\u003eWire Color Coding: BK (Black), RD (Red), YW (Yellow), WT (White), BU (Blue), GN (Green), and OG (Orange).\u003c\/li\u003e\n            \u003cli\u003eFor reliable auto-reset performance, power the valve for at least 60 seconds (≥60s) during first commissioning or after a prolonged power cut.\u003c\/li\u003e\n            \u003cli\u003eBefore manual operation, disconnect power and wait briefly for the actuator to discharge.\u003c\/li\u003e\n        \u003c\/ul\u003e\n    \u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- FAQ --\u003e\n\u003cdiv\u003e\n    \u003ch2 class=\"section-title\"\u003eFAQ\u003c\/h2\u003e\n    \u003cp class=\"faq\"\u003e\u003cb\u003eProblem 1: What is unique about the connection method of this ball valve?\u003c\/b\u003e\u003c\/p\u003e\n    \u003cdiv class=\"instruction-container\"\u003e\n        \u003cdiv class=\"img-container\"\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/UPVC2\/size-2.jpg\" alt=\"\" style=\"width: 100%; height: auto;\"\u003e\n        \u003c\/div\u003e\n        \u003cdiv class=\"text-container\"\u003e\n            \u003cp class=\"section-description\"\u003e\n                The larger sizes of our ball valve series (1-1\/4\", 1-1\/2\", and 2\") come standard with \u003cstrong\u003e\u003cu\u003eSocket End ports\u003c\/u\u003e\u003c\/strong\u003e for solvent cement bonding and a \u003cstrong\u003e\u003cu\u003eUnion structure\u003c\/u\u003e\u003c\/strong\u003e for easier installation and maintenance, instead of common threaded connections such as NPT or G.\u003cbr\u003e\n                This union design allows the valve body to be installed or removed more easily for maintenance or replacement, without cutting the pipe or rotating the valve body itself.\u003cbr\u003e\n                The pipe sockets are made to a \u003cstrong\u003e\u003cu\u003eUS standard\u003c\/u\u003e\u003c\/strong\u003e. Please note that the Socket Inside Diameter (I.D.) may vary by national standard even for the same nominal size, such as 1-1\/4\". For other connection standards, including British Standard, Japanese Industrial Standard, or others, please contact our customer service team.\n            \u003c\/p\u003e\n        \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cp class=\"faq\"\u003e\u003cb\u003eProblem 2: What precautions apply to auto-return models?\u003c\/b\u003e\u003c\/p\u003e\n    \u003cp class=\"section-description\"\u003e\n        The auto-return ball valve requires a minimum power-on duration of 60 seconds (≥60s). This step is mandatory during first commissioning or after a prolonged power cut to ensure reliable auto-reset performance. Before using the manual override, always disconnect the power first. For auto-return models, please wait for a short period after power is disconnected before manual operation, as the actuator needs time to discharge; otherwise, the valve may be difficult to turn manually.\n    \u003c\/p\u003e\n\n    \u003cp class=\"faq\"\u003e\u003cb\u003eProblem 3: Does this model come with a manual function?\u003c\/b\u003e\u003c\/p\u003e\n    \u003cp class=\"section-description\"\u003e\n        \u003cstrong\u003eYes.\u003c\/strong\u003e The manual override function allows you to control the opening and closing of the valve during a power outage. A hexagonal wrench is included with the valve for this purpose.\n    \u003c\/p\u003e\n\n    \u003cp class=\"faq\"\u003e\u003cb\u003eProblem 4: What should be noted during manual operation?\u003c\/b\u003e\u003c\/p\u003e\n    \u003cp class=\"section-description\"\u003e\n        Power must be disconnected before manual operation. Turn the valve according to the \"O\" and \"S\" indicators: \"O\" = Open, \"S\" = Close. The valve should be turned fully open or fully closed; do not leave it in a middle position, as this may damage the valve. For auto-return models, wait for a short period after disconnecting power before manual operation.\n    \u003c\/p\u003e\n\n    \u003cp class=\"faq\"\u003e\u003cb\u003eProblem 5: How to read the indicator window?\u003c\/b\u003e\u003c\/p\u003e\n    \u003cp class=\"section-description\"\u003e\n        The external arrow shows the valve position. When the arrow points to \"0\", the valve is fully closed; when it points to \"90\", the valve is fully open.\n    \u003c\/p\u003e\n\n    \u003cp class=\"faq\"\u003e\u003cb\u003eProblem 6: What is a Union connection?\u003c\/b\u003e\u003c\/p\u003e\n    \u003cp class=\"section-description\"\u003e\n        A Union connection is a detachable valve structure that allows the valve body to be removed more easily for maintenance or replacement without cutting the pipe. On this product, the pipe connection ends are Socket End ports designed for solvent cement bonding.\n    \u003c\/p\u003e\n\n    \u003cp class=\"faq\"\u003e\u003cb\u003eProblem 7: What should be noted about the four main control methods?\u003c\/b\u003e\u003c\/p\u003e\n    \u003cp class=\"section-description\"\u003e\n        Please pay attention to the wiring type when purchasing. Only auto-return models will automatically return to the closed position when power is lost. Other control methods do not automatically reset after power loss and will remain in their current position.\n    \u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/body\u003e","brand":"U.S. Solid","offers":[{"title":"Default Title","offer_id":47743849890047,"sku":"JFMSV00470","price":161.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/1_e994c5be-5ae2-4c5a-ba29-8d05f9297e7b.jpg?v=1758694453"},{"product_id":"1-1-2-double-union-upvc-motorized-ball-valve-dc-24v-5-wire-with-signal-feedback-auto-return-normally-closed-manual-override-epdm-seal","title":"1-1\/2\" Double Union UPVC Motorized Ball Valve - DC 24V, 5-Wire with Signal Feedback, Auto Return, Normally Closed \u0026 Manual Override, EPDM Seal","description":"\u003cbody\u003e\n    \u003cmeta charset=\"UTF-8\"\u003e\n    \u003cmeta name=\"viewport\" content=\"width=device-width, initial-scale=1.0\"\u003e\n    \u003ctitle\u003eResponsive Page with Multiple Modules\u003c\/title\u003e\n    \u003cstyle\u003e\n\n        .desktop-img {\n            display: block;\n        }\n        .mobile-img {\n            display: none;\n        }\n\n        .section-title {\n            font-size: 22px;\n            line-height: 22px;\n            font-weight: bold;\n            margin: 15px 0 5px;\n            font-family: Arial;\n        }\n\n        .section-title2 {\n            font-size: 22px;\n            line-height: 22px;\n            font-weight: bold;\n            margin: 15px 0 3px;\n            font-family: Arial;\n        }\n\n        .section-title3 {\n            font-size: 22px;\n            line-height: 22px;\n            font-weight: bold;\n            margin: 15px 0 10px;\n            font-family: Arial;\n        }\n\n        .section-description {\n            font-size: 16px;\n            line-height: 26px;\n            margin-top: 0px;\n            margin-bottom: 5px;\n            font-family: Arial;\n        }\n\n        .faq {\n            font-size: 16px;\n            margin: 0;\n            line-height: 26px;\n            background-color: #f2f2f2;\n            padding: 5px;\n        }\n\n        .section-description2 {\n            font-size: 16px;\n            line-height: 26px;\n            margin: 0px;\n            font-family: Arial;\n        }\n\n        .parameters-table-wrapper {\n            overflow-x: auto;\n            -webkit-overflow-scrolling: touch;\n            margin-top: 0px;\n        }\n\n        .parameters-table {\n            width: 100%;\n            min-width: 1000px;\n            border-collapse: collapse;\n            margin-top: 0px;\n        }\n\n        .parameters-table th, .parameters-table td {\n            border-top: 1.2px solid #a6a6a6;\n            border-bottom: 1.2px solid #a6a6a6;\n            border-left: none;\n            border-right: none;\n            padding: 5px 2px;\n            text-align: left;\n            font-size: 16px;\n            line-height: 16px;\n        }\n\n        .parameters-table th {\n            background-color: #f2f2f2;\n            color: #2c2c2c;\n            font-weight: bold;\n        }\n\n        .parameters-table .bg-gray {\n            background-color: #f2f2f2;\n        }\n\n        .options-table-wrapper {\n            overflow-x: auto;\n            -webkit-overflow-scrolling: touch;\n            margin-top: 0px;\n        }\n\n        .options-table {\n            width: 100%;\n            min-width: 1000px;\n            border-collapse: collapse;\n            margin-top: 0px;\n            box-shadow: 0 6px 25px rgba(0, 0, 0, 0.1);\n        }\n\n        .options-table th, .options-table td {\n            border: 2px solid #000;\n            padding: 5px 2px;\n            text-align: center;\n            font-size: 16px;\n            line-height: 16px;\n        }\n\n        .options-table th {\n            background-color: #f2f2f2;\n            color: #2c2c2c;\n            font-weight: bold;\n        }\n\n        .parameters-table2 {\n            width: 100%;\n            min-width: 1000px;\n            border-collapse: collapse;\n            margin-top: 0px;\n        }\n\n        .parameters-table2 th, .parameters-table2 td {\n            border-top: 1.2px solid #a6a6a6;\n            border-bottom: 1.2px solid #a6a6a6;\n            border-left: none;\n            border-right: none;\n            padding: 5px 2px;\n            text-align: center;\n            font-size: 16px;\n            line-height: 16px;\n        }\n\n        .parameters-table2 th {\n            background-color: #f2f2f2;\n            color: #2c2c2c;\n            font-weight: bold;\n        }\n\n        .parameters-table2 .bg-gray {\n            background-color: #f2f2f2;\n        }\n\n        .options-table-wrapper2 {\n            overflow-x: auto;\n            -webkit-overflow-scrolling: touch;\n            margin-top: 0px;\n        }\n\n        .instruction-container {\n            display: flex;\n            justify-content: space-between;\n            align-items: flex-start;\n            gap: 10px;\n            margin-bottom: 0px;\n        }\n\n        .img-container {\n            width: 35%;\n            display: flex;\n            justify-content: center;\n        }\n\n        .text-container {\n            width: 65%;\n            font-size: 16px;\n            font-family: Arial;\n        }\n\n        .instruction-container2 {\n            display: flex;\n            justify-content: space-between;\n            align-items: flex-start;\n            gap: 10px;\n            margin-bottom: 0px;\n        }\n\n        .img-container2 {\n            width: 50%;\n            display: flex;\n            justify-content: center;\n        }\n\n        .text-container2 {\n            width: 50%;\n            display: flex;\n            justify-content: center;\n        }\n\n        @media (max-width: 768px) {\n            .parameters-table th, .parameters-table td {\n                font-size: 14px;\n                padding: 8px 4px;\n            }\n\n            .options-table th, .options-table td {\n                font-size: 14px;\n                padding: 8px 4px;\n            }\n\n            .parameters-table-wrapper {\n                overflow-x: auto;\n            }\n\n            .parameters-table2 th, .parameters-table2 td {\n                font-size: 14px;\n                padding: 8px 4px;\n            }\n\n            .parameters-table-wrapper2 {\n                overflow-x: auto;\n            }\n\n            .desktop-img {\n                display: none;\n            }\n\n            .mobile-img {\n                display: block;\n            }\n\n            .instruction-container {\n                flex-direction: column;\n                align-items: center;\n            }\n\n            .img-container, .text-container {\n                width: 100%;\n                margin-bottom: 0px;\n            }\n\n            .instruction-container2 {\n                flex-direction: column;\n                align-items: center;\n            }\n\n            .img-container2, .text-container2 {\n                width: 100%;\n                margin-bottom: 0px;\n            }\n        }\n\n        @media (max-width: 480px) {\n            .parameters-table th, .parameters-table td {\n                font-size: 12px;\n                padding: 6px 3px;\n            }\n\n            .options-table th, .options-table td {\n                font-size: 12px;\n            }\n\n            .parameters-table-wrapper {\n                overflow-x: auto;\n            }\n\n            .parameters-table2 th, .parameters-table2 td {\n                font-size: 12px;\n                padding: 6px 3px;\n            }\n\n            .parameters-table-wrapper2 {\n                overflow-x: auto;\n            }\n\n            .desktop-img {\n                display: none;\n            }\n\n            .mobile-img {\n                display: block;\n            }\n\n            .instruction-container {\n                flex-direction: column;\n            }\n\n            .instruction-container2 {\n                flex-direction: column;\n            }\n        }\n\n    \u003c\/style\u003e\n\n\u003c!-- Background --\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/UPVC2\/b.jpg\" class=\"desktop-img\" alt=\"Desktop Image 1\"\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/UPVC2\/b-p.jpg\" class=\"mobile-img\" alt=\"Mobile Image 1\"\u003e\n\u003c!-- Introduction - 5-Wire Auto Return \/ With Signal Feedback --\u003e\n\u003cdiv\u003e\n    \u003ch2 class=\"section-title\"\u003eIntroduction\u003c\/h2\u003e\n    \u003cp class=\"section-description\"\u003e\n        Our electric UPVC ball valve series has been upgraded to include three larger sizes: 1-1\/4\", 1-1\/2\", and 2\". These larger valves feature a unique \u003cstrong\u003e\u003cu\u003eUS standard socket end \u0026amp; double union connection\u003c\/u\u003e\u003c\/strong\u003e—enabling exceptional ease of installation and maintenance with a simple solvent cement bond, \u003cstrong\u003e\u003cu\u003eunlike\u003c\/u\u003e\u003c\/strong\u003e threaded NPT or G connections. For other connection standards, please contact our customer service.\u003cbr\u003eThese valves feature a \u003cstrong\u003e\u003cu\u003e5-wire auto-return configuration with signal feedback\u003c\/u\u003e\u003c\/strong\u003e and remain in a normally-closed position. They use two wires for power supply and three dedicated wires for signal feedback only, providing open\/closed position signaling to your control system. For safety, they automatically close if power is lost. A manual override is also included for use during power outages. All valves have EPDM seals for reliable performance.\n    \u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- Applications--\u003e\n     \u003ch2 class=\"section-title2\"\u003eApplications\u003c\/h2\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/UPVC2\/a.jpg\" class=\"desktop-img\" alt=\"Desktop Image 1\"\u003e\n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/UPVC2\/a-p.jpg\" class=\"mobile-img\" alt=\"Desktop Image 2\"\u003e\n\u003c!-- Features - 5-Wire Auto Return with Signal Feedback --\u003e\n\u003cdiv\u003e\n    \u003ch2 class=\"section-title\"\u003eFeatures\u003c\/h2\u003e\n    \u003cul class=\"section-description2\"\u003e\n        \u003cli\u003e\n\u003cstrong\u003eUnion \u0026amp; Socket End:\u003c\/strong\u003e Different from standard NPT\/G threaded connections, it uses socket-gluing for sealing and integrates threaded structures, balancing connection stability with quick disassembly and maintenance needs.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eManual Function:\u003c\/strong\u003e Comes with a hex wrench as standard; allows manual valve opening and closing during power outages. \"O\"=Open, \"S\"=Close.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eIndicator Window:\u003c\/strong\u003e Built-in engraved marks directly show the valve's open\/closed status. External arrow pointing to \"0\" means fully closed; pointing to \"90\" means fully open.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003ePremium Material:\u003c\/strong\u003e Valve body made of UPVC with EPDM seals, meeting general operating requirements.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003e5-Wire Auto Return with Signal Feedback:\u003c\/strong\u003e Uses two wires for power supply and three dedicated wires for signal feedback. The valve remains normally closed, automatically closes when power is lost, and provides open\/closed position feedback to a control or monitoring system.\u003c\/li\u003e\n    \u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/UPVC2\/5-Return.jpg\" class=\"desktop-img\" alt=\"Desktop Image 1\"\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/UPVC2\/5-Return-p.jpg\" class=\"mobile-img\" alt=\"Desktop Image 2\"\u003e\n\u003c!-- User Manual --\u003e\n\u003cdiv\u003e\n    \u003ch2 class=\"section-title\"\u003eUser Manual\u003c\/h2\u003e\n    \u003cp class=\"section-description\"\u003e\n        To learn how to use this product, please refer to the \u003ca href=\"https:\/\/file.ussolid.com\/content\/JFMSV\/Manual-%20USS-UPVC.pdf\" target=\"_blank\"\u003euser manual\u003c\/a\u003e.\n    \u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- Technical Data --\u003e\n    \u003ch2 class=\"section-title3\"\u003eTechnical Data\u003c\/h2\u003e \n    \u003cdiv class=\"parameters-table-wrapper\"\u003e\n        \u003ctable class=\"parameters-table\"\u003e\n            \u003ctbody\u003e \n                \u003ctr\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003ePort Size\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003e1 1\/2\"\u003c\/td\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003eUSS-MSV471\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003ePort\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003e2 Way\u003c\/td\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eThread\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003eNo Thread\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eConnection\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003eUnion \u0026amp; Socket End\u003c\/td\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eMax Power\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003e36W\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eSocket Inside Diameter\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003e48.3mm (US Standard)\u003c\/td\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eWith Hex Wrench\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003eYes\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eWiring\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003e5-Wire (2-Wire Auto Return + Signal Feedback)\u003c\/td\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eManual Function\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003eYes\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eSignal feedback function\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003eYes\u003c\/td\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eIndicator Window\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003eYes\u003c\/td\u003e\n                \u003c\/tr\u003e\n\n                \u003ctr\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eBody Material\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003eUPVC\u003c\/td\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eNormal Position\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003eNormally Closed\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eSeal Material\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003eEPDM\u003c\/td\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eTemp Range (Medium)\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003e33.8℉ to 104℉\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eWorking Voltage\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003eDC 24V\u003c\/td\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eClose\/Open Time\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003e10-12s\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eMax Torque\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003e20 N·m\u003c\/td\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eMax. Pressure\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003e232 psi\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eLife Expectancy\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003e20,000 Cycles\u003c\/td\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eIP Rating\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003eIP65\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003ePackage Size\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003e9.1\"x7.1\"x4.7\"\u003c\/td\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eGross Weight\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003e3.97 lb\u003c\/td\u003e\n                \u003c\/tr\u003e \n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n    \u003cp class=\"section-description\"\u003e*To view the full table on mobile, please swipe left or right on the screen.\u003c\/p\u003e\n\u003c!-- Wiring - 5-Wire Auto Return with Signal Feedback --\u003e\n\u003ch2 class=\"section-title\"\u003e5-Wire (2-Wire Auto Return + Signal Feedback)\u003c\/h2\u003e\n\u003cdiv class=\"instruction-container\"\u003e\n    \u003cdiv class=\"img-container\"\u003e\n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Wire\/return.jpg\" alt=\"\" style=\"width: 100%; height: auto;\"\u003e\n    \u003c\/div\u003e\n    \u003cdiv class=\"text-container\"\u003e\n        \u003cp class=\"section-description\"\u003e\n            This model uses a 5-wire wiring method that combines 2-wire auto-return control with signal feedback. It includes two wires for power supply and three wires for open\/closed position feedback. The valve is normally closed by default: it opens when powered and automatically returns to the closed position when power is lost or disconnected.\n        \u003c\/p\u003e\n        \u003cul class=\"section-description2\"\u003e\n            \u003cli\u003eConnect the power and signal feedback wires according to the wiring diagram.\u003c\/li\u003e\n            \u003cli\u003eWire Color Coding: BK (Black), RD (Red), YW (Yellow), WT (White), BU (Blue), GN (Green), and OG (Orange).\u003c\/li\u003e\n            \u003cli\u003eFor reliable auto-reset performance, power the valve for at least 60 seconds (≥60s) during first commissioning or after a prolonged power cut.\u003c\/li\u003e\n            \u003cli\u003eBefore manual operation, disconnect power and wait briefly for the actuator to discharge.\u003c\/li\u003e\n        \u003c\/ul\u003e\n    \u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- FAQ --\u003e\n\u003cdiv\u003e\n    \u003ch2 class=\"section-title\"\u003eFAQ\u003c\/h2\u003e\n    \u003cp class=\"faq\"\u003e\u003cb\u003eProblem 1: What is unique about the connection method of this ball valve?\u003c\/b\u003e\u003c\/p\u003e\n    \u003cdiv class=\"instruction-container\"\u003e\n        \u003cdiv class=\"img-container\"\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/UPVC2\/size-2.jpg\" alt=\"\" style=\"width: 100%; height: auto;\"\u003e\n        \u003c\/div\u003e\n        \u003cdiv class=\"text-container\"\u003e\n            \u003cp class=\"section-description\"\u003e\n                The larger sizes of our ball valve series (1-1\/4\", 1-1\/2\", and 2\") come standard with \u003cstrong\u003e\u003cu\u003eSocket End ports\u003c\/u\u003e\u003c\/strong\u003e for solvent cement bonding and a \u003cstrong\u003e\u003cu\u003eUnion structure\u003c\/u\u003e\u003c\/strong\u003e for easier installation and maintenance, instead of common threaded connections such as NPT or G.\u003cbr\u003e\n                This union design allows the valve body to be installed or removed more easily for maintenance or replacement, without cutting the pipe or rotating the valve body itself.\u003cbr\u003e\n                The pipe sockets are made to a \u003cstrong\u003e\u003cu\u003eUS standard\u003c\/u\u003e\u003c\/strong\u003e. Please note that the Socket Inside Diameter (I.D.) may vary by national standard even for the same nominal size, such as 1-1\/4\". For other connection standards, including British Standard, Japanese Industrial Standard, or others, please contact our customer service team.\n            \u003c\/p\u003e\n        \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cp class=\"faq\"\u003e\u003cb\u003eProblem 2: What precautions apply to auto-return models?\u003c\/b\u003e\u003c\/p\u003e\n    \u003cp class=\"section-description\"\u003e\n        The auto-return ball valve requires a minimum power-on duration of 60 seconds (≥60s). This step is mandatory during first commissioning or after a prolonged power cut to ensure reliable auto-reset performance. Before using the manual override, always disconnect the power first. For auto-return models, please wait for a short period after power is disconnected before manual operation, as the actuator needs time to discharge; otherwise, the valve may be difficult to turn manually.\n    \u003c\/p\u003e\n\n    \u003cp class=\"faq\"\u003e\u003cb\u003eProblem 3: Does this model come with a manual function?\u003c\/b\u003e\u003c\/p\u003e\n    \u003cp class=\"section-description\"\u003e\n        \u003cstrong\u003eYes.\u003c\/strong\u003e The manual override function allows you to control the opening and closing of the valve during a power outage. A hexagonal wrench is included with the valve for this purpose.\n    \u003c\/p\u003e\n\n    \u003cp class=\"faq\"\u003e\u003cb\u003eProblem 4: What should be noted during manual operation?\u003c\/b\u003e\u003c\/p\u003e\n    \u003cp class=\"section-description\"\u003e\n        Power must be disconnected before manual operation. Turn the valve according to the \"O\" and \"S\" indicators: \"O\" = Open, \"S\" = Close. The valve should be turned fully open or fully closed; do not leave it in a middle position, as this may damage the valve. For auto-return models, wait for a short period after disconnecting power before manual operation.\n    \u003c\/p\u003e\n\n    \u003cp class=\"faq\"\u003e\u003cb\u003eProblem 5: How to read the indicator window?\u003c\/b\u003e\u003c\/p\u003e\n    \u003cp class=\"section-description\"\u003e\n        The external arrow shows the valve position. When the arrow points to \"0\", the valve is fully closed; when it points to \"90\", the valve is fully open.\n    \u003c\/p\u003e\n\n    \u003cp class=\"faq\"\u003e\u003cb\u003eProblem 6: What is a Union connection?\u003c\/b\u003e\u003c\/p\u003e\n    \u003cp class=\"section-description\"\u003e\n        A Union connection is a detachable valve structure that allows the valve body to be removed more easily for maintenance or replacement without cutting the pipe. On this product, the pipe connection ends are Socket End ports designed for solvent cement bonding.\n    \u003c\/p\u003e\n\n    \u003cp class=\"faq\"\u003e\u003cb\u003eProblem 7: What should be noted about the four main control methods?\u003c\/b\u003e\u003c\/p\u003e\n    \u003cp class=\"section-description\"\u003e\n        Please pay attention to the wiring type when purchasing. Only auto-return models will automatically return to the closed position when power is lost. Other control methods do not automatically reset after power loss and will remain in their current position.\n    \u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/body\u003e","brand":"U.S. Solid","offers":[{"title":"Default Title","offer_id":47743850086655,"sku":"JFMSV00471","price":171.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/2_9c8be148-836c-4030-8810-599b2b24aea6.jpg?v=1758694502"},{"product_id":"2-double-union-upvc-motorized-ball-valve-dc-24v-5-wire-with-signal-feedback-auto-return-normally-closed-manual-override-epdm-seal","title":"2\" Double Union UPVC Motorized Ball Valve - DC 24V, 5-Wire with Signal Feedback, Auto Return, Normally Closed \u0026 Manual Override, EPDM Seal","description":"\u003cbody\u003e\n    \u003cmeta charset=\"UTF-8\"\u003e\n    \u003cmeta name=\"viewport\" content=\"width=device-width, initial-scale=1.0\"\u003e\n    \u003ctitle\u003eResponsive Page with Multiple Modules\u003c\/title\u003e\n    \u003cstyle\u003e\n\n        .desktop-img {\n            display: block;\n        }\n        .mobile-img {\n            display: none;\n        }\n\n        .section-title {\n            font-size: 22px;\n            line-height: 22px;\n            font-weight: bold;\n            margin: 15px 0 5px;\n            font-family: Arial;\n        }\n\n        .section-title2 {\n            font-size: 22px;\n            line-height: 22px;\n            font-weight: bold;\n            margin: 15px 0 3px;\n            font-family: Arial;\n        }\n\n        .section-title3 {\n            font-size: 22px;\n            line-height: 22px;\n            font-weight: bold;\n            margin: 15px 0 10px;\n            font-family: Arial;\n        }\n\n        .section-description {\n            font-size: 16px;\n            line-height: 26px;\n            margin-top: 0px;\n            margin-bottom: 5px;\n            font-family: Arial;\n        }\n\n        .faq {\n            font-size: 16px;\n            margin: 0;\n            line-height: 26px;\n            background-color: #f2f2f2;\n            padding: 5px;\n        }\n\n        .section-description2 {\n            font-size: 16px;\n            line-height: 26px;\n            margin: 0px;\n            font-family: Arial;\n        }\n\n        .parameters-table-wrapper {\n            overflow-x: auto;\n            -webkit-overflow-scrolling: touch;\n            margin-top: 0px;\n        }\n\n        .parameters-table {\n            width: 100%;\n            min-width: 1000px;\n            border-collapse: collapse;\n            margin-top: 0px;\n        }\n\n        .parameters-table th, .parameters-table td {\n            border-top: 1.2px solid #a6a6a6;\n            border-bottom: 1.2px solid #a6a6a6;\n            border-left: none;\n            border-right: none;\n            padding: 5px 2px;\n            text-align: left;\n            font-size: 16px;\n            line-height: 16px;\n        }\n\n        .parameters-table th {\n            background-color: #f2f2f2;\n            color: #2c2c2c;\n            font-weight: bold;\n        }\n\n        .parameters-table .bg-gray {\n            background-color: #f2f2f2;\n        }\n\n        .options-table-wrapper {\n            overflow-x: auto;\n            -webkit-overflow-scrolling: touch;\n            margin-top: 0px;\n        }\n\n        .options-table {\n            width: 100%;\n            min-width: 1000px;\n            border-collapse: collapse;\n            margin-top: 0px;\n            box-shadow: 0 6px 25px rgba(0, 0, 0, 0.1);\n        }\n\n        .options-table th, .options-table td {\n            border: 2px solid #000;\n            padding: 5px 2px;\n            text-align: center;\n            font-size: 16px;\n            line-height: 16px;\n        }\n\n        .options-table th {\n            background-color: #f2f2f2;\n            color: #2c2c2c;\n            font-weight: bold;\n        }\n\n        .parameters-table2 {\n            width: 100%;\n            min-width: 1000px;\n            border-collapse: collapse;\n            margin-top: 0px;\n        }\n\n        .parameters-table2 th, .parameters-table2 td {\n            border-top: 1.2px solid #a6a6a6;\n            border-bottom: 1.2px solid #a6a6a6;\n            border-left: none;\n            border-right: none;\n            padding: 5px 2px;\n            text-align: center;\n            font-size: 16px;\n            line-height: 16px;\n        }\n\n        .parameters-table2 th {\n            background-color: #f2f2f2;\n            color: #2c2c2c;\n            font-weight: bold;\n        }\n\n        .parameters-table2 .bg-gray {\n            background-color: #f2f2f2;\n        }\n\n        .options-table-wrapper2 {\n            overflow-x: auto;\n            -webkit-overflow-scrolling: touch;\n            margin-top: 0px;\n        }\n\n        .instruction-container {\n            display: flex;\n            justify-content: space-between;\n            align-items: flex-start;\n            gap: 10px;\n            margin-bottom: 0px;\n        }\n\n        .img-container {\n            width: 35%;\n            display: flex;\n            justify-content: center;\n        }\n\n        .text-container {\n            width: 65%;\n            font-size: 16px;\n            font-family: Arial;\n        }\n\n        .instruction-container2 {\n            display: flex;\n            justify-content: space-between;\n            align-items: flex-start;\n            gap: 10px;\n            margin-bottom: 0px;\n        }\n\n        .img-container2 {\n            width: 50%;\n            display: flex;\n            justify-content: center;\n        }\n\n        .text-container2 {\n            width: 50%;\n            display: flex;\n            justify-content: center;\n        }\n\n        @media (max-width: 768px) {\n            .parameters-table th, .parameters-table td {\n                font-size: 14px;\n                padding: 8px 4px;\n            }\n\n            .options-table th, .options-table td {\n                font-size: 14px;\n                padding: 8px 4px;\n            }\n\n            .parameters-table-wrapper {\n                overflow-x: auto;\n            }\n\n            .parameters-table2 th, .parameters-table2 td {\n                font-size: 14px;\n                padding: 8px 4px;\n            }\n\n            .parameters-table-wrapper2 {\n                overflow-x: auto;\n            }\n\n            .desktop-img {\n                display: none;\n            }\n\n            .mobile-img {\n                display: block;\n            }\n\n            .instruction-container {\n                flex-direction: column;\n                align-items: center;\n            }\n\n            .img-container, .text-container {\n                width: 100%;\n                margin-bottom: 0px;\n            }\n\n            .instruction-container2 {\n                flex-direction: column;\n                align-items: center;\n            }\n\n            .img-container2, .text-container2 {\n                width: 100%;\n                margin-bottom: 0px;\n            }\n        }\n\n        @media (max-width: 480px) {\n            .parameters-table th, .parameters-table td {\n                font-size: 12px;\n                padding: 6px 3px;\n            }\n\n            .options-table th, .options-table td {\n                font-size: 12px;\n            }\n\n            .parameters-table-wrapper {\n                overflow-x: auto;\n            }\n\n            .parameters-table2 th, .parameters-table2 td {\n                font-size: 12px;\n                padding: 6px 3px;\n            }\n\n            .parameters-table-wrapper2 {\n                overflow-x: auto;\n            }\n\n            .desktop-img {\n                display: none;\n            }\n\n            .mobile-img {\n                display: block;\n            }\n\n            .instruction-container {\n                flex-direction: column;\n            }\n\n            .instruction-container2 {\n                flex-direction: column;\n            }\n        }\n\n    \u003c\/style\u003e\n\n\u003c!-- Background --\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/UPVC2\/b.jpg\" class=\"desktop-img\" alt=\"Desktop Image 1\"\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/UPVC2\/b-p.jpg\" class=\"mobile-img\" alt=\"Mobile Image 1\"\u003e\n\u003c!-- Introduction - 5-Wire Auto Return \/ With Signal Feedback --\u003e\n\u003cdiv\u003e\n    \u003ch2 class=\"section-title\"\u003eIntroduction\u003c\/h2\u003e\n    \u003cp class=\"section-description\"\u003e\n        Our electric UPVC ball valve series has been upgraded to include three larger sizes: 1-1\/4\", 1-1\/2\", and 2\". These larger valves feature a unique \u003cstrong\u003e\u003cu\u003eUS standard socket end \u0026amp; double union connection\u003c\/u\u003e\u003c\/strong\u003e—enabling exceptional ease of installation and maintenance with a simple solvent cement bond, \u003cstrong\u003e\u003cu\u003eunlike\u003c\/u\u003e\u003c\/strong\u003e threaded NPT or G connections. For other connection standards, please contact our customer service.\u003cbr\u003eThese valves feature a \u003cstrong\u003e\u003cu\u003e5-wire auto-return configuration with signal feedback\u003c\/u\u003e\u003c\/strong\u003e and remain in a normally-closed position. They use two wires for power supply and three dedicated wires for signal feedback only, providing open\/closed position signaling to your control system. For safety, they automatically close if power is lost. A manual override is also included for use during power outages. All valves have EPDM seals for reliable performance.\n    \u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- Applications--\u003e\n     \u003ch2 class=\"section-title2\"\u003eApplications\u003c\/h2\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/UPVC2\/a.jpg\" class=\"desktop-img\" alt=\"Desktop Image 1\"\u003e\n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/UPVC2\/a-p.jpg\" class=\"mobile-img\" alt=\"Desktop Image 2\"\u003e\n\u003c!-- Features - 5-Wire Auto Return with Signal Feedback --\u003e\n\u003cdiv\u003e\n    \u003ch2 class=\"section-title\"\u003eFeatures\u003c\/h2\u003e\n    \u003cul class=\"section-description2\"\u003e\n        \u003cli\u003e\n\u003cstrong\u003eUnion \u0026amp; Socket End:\u003c\/strong\u003e Different from standard NPT\/G threaded connections, it uses socket-gluing for sealing and integrates threaded structures, balancing connection stability with quick disassembly and maintenance needs.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eManual Function:\u003c\/strong\u003e Comes with a hex wrench as standard; allows manual valve opening and closing during power outages. \"O\"=Open, \"S\"=Close.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eIndicator Window:\u003c\/strong\u003e Built-in engraved marks directly show the valve's open\/closed status. External arrow pointing to \"0\" means fully closed; pointing to \"90\" means fully open.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003ePremium Material:\u003c\/strong\u003e Valve body made of UPVC with EPDM seals, meeting general operating requirements.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003e5-Wire Auto Return with Signal Feedback:\u003c\/strong\u003e Uses two wires for power supply and three dedicated wires for signal feedback. The valve remains normally closed, automatically closes when power is lost, and provides open\/closed position feedback to a control or monitoring system.\u003c\/li\u003e\n    \u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/UPVC2\/5-Return.jpg\" class=\"desktop-img\" alt=\"Desktop Image 1\"\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/UPVC2\/5-Return-p.jpg\" class=\"mobile-img\" alt=\"Desktop Image 2\"\u003e\n\u003c!-- User Manual --\u003e\n\u003cdiv\u003e\n    \u003ch2 class=\"section-title\"\u003eUser Manual\u003c\/h2\u003e\n    \u003cp class=\"section-description\"\u003e\n        To learn how to use this product, please refer to the \u003ca href=\"https:\/\/file.ussolid.com\/content\/JFMSV\/Manual-%20USS-UPVC.pdf\" target=\"_blank\"\u003euser manual\u003c\/a\u003e.\n    \u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- Technical Data --\u003e\n    \u003ch2 class=\"section-title3\"\u003eTechnical Data\u003c\/h2\u003e \n    \u003cdiv class=\"parameters-table-wrapper\"\u003e\n        \u003ctable class=\"parameters-table\"\u003e\n            \u003ctbody\u003e \n                \u003ctr\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003ePort Size\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003e2\"\u003c\/td\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003eUSS-MSV472\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003ePort\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003e2 Way\u003c\/td\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eThread\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003eNo Thread\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eConnection\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003eUnion \u0026amp; Socket End\u003c\/td\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eMax Power\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003e36W\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eSocket Inside Diameter\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003e60.3mm (US Standard)\u003c\/td\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eWith Hex Wrench\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003eYes\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eWiring\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003e5-Wire (2-Wire Auto Return + Signal Feedback)\u003c\/td\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eManual Function\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003eYes\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eSignal feedback function\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003eYes\u003c\/td\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eIndicator Window\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003eYes\u003c\/td\u003e\n                \u003c\/tr\u003e\n\n                \u003ctr\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eBody Material\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003eUPVC\u003c\/td\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eNormal Position\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003eNormally Closed\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eSeal Material\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003eEPDM\u003c\/td\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eTemp Range (Medium)\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003e33.8℉ to 104℉\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eWorking Voltage\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003eDC 24V\u003c\/td\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eClose\/Open Time\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003e10-12s\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eMax Torque\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003e20 N·m\u003c\/td\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eMax. Pressure\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003e232 psi\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eLife Expectancy\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003e20,000 Cycles\u003c\/td\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eIP Rating\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003eIP65\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003ePackage Size\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003e9.8\"x8.7\"x5.9\"\u003c\/td\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eGross Weight\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003e5.51 lb\u003c\/td\u003e\n                \u003c\/tr\u003e \n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n    \u003cp class=\"section-description\"\u003e*To view the full table on mobile, please swipe left or right on the screen.\u003c\/p\u003e\n\u003c!-- Wiring - 5-Wire Auto Return with Signal Feedback --\u003e\n\u003ch2 class=\"section-title\"\u003e5-Wire (2-Wire Auto Return + Signal Feedback)\u003c\/h2\u003e\n\u003cdiv class=\"instruction-container\"\u003e\n    \u003cdiv class=\"img-container\"\u003e\n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Wire\/return.jpg\" alt=\"\" style=\"width: 100%; height: auto;\"\u003e\n    \u003c\/div\u003e\n    \u003cdiv class=\"text-container\"\u003e\n        \u003cp class=\"section-description\"\u003e\n            This model uses a 5-wire wiring method that combines 2-wire auto-return control with signal feedback. It includes two wires for power supply and three wires for open\/closed position feedback. The valve is normally closed by default: it opens when powered and automatically returns to the closed position when power is lost or disconnected.\n        \u003c\/p\u003e\n        \u003cul class=\"section-description2\"\u003e\n            \u003cli\u003eConnect the power and signal feedback wires according to the wiring diagram.\u003c\/li\u003e\n            \u003cli\u003eWire Color Coding: BK (Black), RD (Red), YW (Yellow), WT (White), BU (Blue), GN (Green), and OG (Orange).\u003c\/li\u003e\n            \u003cli\u003eFor reliable auto-reset performance, power the valve for at least 60 seconds (≥60s) during first commissioning or after a prolonged power cut.\u003c\/li\u003e\n            \u003cli\u003eBefore manual operation, disconnect power and wait briefly for the actuator to discharge.\u003c\/li\u003e\n        \u003c\/ul\u003e\n    \u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- FAQ --\u003e\n\u003cdiv\u003e\n    \u003ch2 class=\"section-title\"\u003eFAQ\u003c\/h2\u003e\n    \u003cp class=\"faq\"\u003e\u003cb\u003eProblem 1: What is unique about the connection method of this ball valve?\u003c\/b\u003e\u003c\/p\u003e\n    \u003cdiv class=\"instruction-container\"\u003e\n        \u003cdiv class=\"img-container\"\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/UPVC2\/size-2.jpg\" alt=\"\" style=\"width: 100%; height: auto;\"\u003e\n        \u003c\/div\u003e\n        \u003cdiv class=\"text-container\"\u003e\n            \u003cp class=\"section-description\"\u003e\n                The larger sizes of our ball valve series (1-1\/4\", 1-1\/2\", and 2\") come standard with \u003cstrong\u003e\u003cu\u003eSocket End ports\u003c\/u\u003e\u003c\/strong\u003e for solvent cement bonding and a \u003cstrong\u003e\u003cu\u003eUnion structure\u003c\/u\u003e\u003c\/strong\u003e for easier installation and maintenance, instead of common threaded connections such as NPT or G.\u003cbr\u003e\n                This union design allows the valve body to be installed or removed more easily for maintenance or replacement, without cutting the pipe or rotating the valve body itself.\u003cbr\u003e\n                The pipe sockets are made to a \u003cstrong\u003e\u003cu\u003eUS standard\u003c\/u\u003e\u003c\/strong\u003e. Please note that the Socket Inside Diameter (I.D.) may vary by national standard even for the same nominal size, such as 1-1\/4\". For other connection standards, including British Standard, Japanese Industrial Standard, or others, please contact our customer service team.\n            \u003c\/p\u003e\n        \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cp class=\"faq\"\u003e\u003cb\u003eProblem 2: What precautions apply to auto-return models?\u003c\/b\u003e\u003c\/p\u003e\n    \u003cp class=\"section-description\"\u003e\n        The auto-return ball valve requires a minimum power-on duration of 60 seconds (≥60s). This step is mandatory during first commissioning or after a prolonged power cut to ensure reliable auto-reset performance. Before using the manual override, always disconnect the power first. For auto-return models, please wait for a short period after power is disconnected before manual operation, as the actuator needs time to discharge; otherwise, the valve may be difficult to turn manually.\n    \u003c\/p\u003e\n\n    \u003cp class=\"faq\"\u003e\u003cb\u003eProblem 3: Does this model come with a manual function?\u003c\/b\u003e\u003c\/p\u003e\n    \u003cp class=\"section-description\"\u003e\n        \u003cstrong\u003eYes.\u003c\/strong\u003e The manual override function allows you to control the opening and closing of the valve during a power outage. A hexagonal wrench is included with the valve for this purpose.\n    \u003c\/p\u003e\n\n    \u003cp class=\"faq\"\u003e\u003cb\u003eProblem 4: What should be noted during manual operation?\u003c\/b\u003e\u003c\/p\u003e\n    \u003cp class=\"section-description\"\u003e\n        Power must be disconnected before manual operation. Turn the valve according to the \"O\" and \"S\" indicators: \"O\" = Open, \"S\" = Close. The valve should be turned fully open or fully closed; do not leave it in a middle position, as this may damage the valve. For auto-return models, wait for a short period after disconnecting power before manual operation.\n    \u003c\/p\u003e\n\n    \u003cp class=\"faq\"\u003e\u003cb\u003eProblem 5: How to read the indicator window?\u003c\/b\u003e\u003c\/p\u003e\n    \u003cp class=\"section-description\"\u003e\n        The external arrow shows the valve position. When the arrow points to \"0\", the valve is fully closed; when it points to \"90\", the valve is fully open.\n    \u003c\/p\u003e\n\n    \u003cp class=\"faq\"\u003e\u003cb\u003eProblem 6: What is a Union connection?\u003c\/b\u003e\u003c\/p\u003e\n    \u003cp class=\"section-description\"\u003e\n        A Union connection is a detachable valve structure that allows the valve body to be removed more easily for maintenance or replacement without cutting the pipe. On this product, the pipe connection ends are Socket End ports designed for solvent cement bonding.\n    \u003c\/p\u003e\n\n    \u003cp class=\"faq\"\u003e\u003cb\u003eProblem 7: What should be noted about the four main control methods?\u003c\/b\u003e\u003c\/p\u003e\n    \u003cp class=\"section-description\"\u003e\n        Please pay attention to the wiring type when purchasing. Only auto-return models will automatically return to the closed position when power is lost. Other control methods do not automatically reset after power loss and will remain in their current position.\n    \u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/body\u003e","brand":"U.S. Solid","offers":[{"title":"Default Title","offer_id":47743850479871,"sku":"JFMSV00472","price":181.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/3_c2e2f334-14b7-4e14-892b-83f625b659fa.jpg?v=1758694547"},{"product_id":"upvc-3-way-motorized-ball-valve-l-type-union-socket-end-2-wire-auto-return-dc-24v-with-manual-override","title":"1\/2\" UPVC 3-Way Motorized Ball Valve (L Type), Union \u0026 Socket End, 2 Wire Auto Return, DC 24V, with Manual Override","description":"\u003cbody\u003e\n    \u003cmeta charset=\"UTF-8\"\u003e\n    \u003cmeta name=\"viewport\" content=\"width=device-width, initial-scale=1.0\"\u003e\n    \u003ctitle\u003eResponsive Page with Multiple Modules\u003c\/title\u003e\n    \u003cstyle\u003e\n\n        .desktop-img {\n            display: block;\n        }\n        .mobile-img {\n            display: none;\n        }\n\n        .section-title {\n            font-size: 22px;\n            line-height: 22px;\n            font-weight: bold;\n            margin: 15px 0 5px;\n            font-family: Arial;\n        }\n\n        .section-title2 {\n            font-size: 22px;\n            line-height: 22px;\n            font-weight: bold;\n            margin: 15px 0 3px;\n            font-family: Arial;\n        }\n\n        .section-title3 {\n            font-size: 22px;\n            line-height: 22px;\n            font-weight: bold;\n            margin: 15px 0 10px;\n            font-family: Arial;\n        }\n\n        .section-description {\n            font-size: 16px;\n            line-height: 26px;\n            margin-top: 0px;\n            margin-bottom: 5px;\n            font-family: Arial;\n        }\n\n        .faq {\n            font-size: 16px;\n            margin: 0;\n            line-height: 26px;\n            background-color: #f2f2f2;\n            padding: 5px;\n        }\n\n        .section-description2 {\n            font-size: 16px;\n            line-height: 26px;\n            margin: 0px;\n            font-family: Arial;\n        }\n\n        .parameters-table-wrapper {\n            overflow-x: auto;\n            -webkit-overflow-scrolling: touch;\n            margin-top: 0px;\n        }\n\n        .parameters-table {\n            width: 100%;\n            min-width: 1000px;\n            border-collapse: collapse;\n            margin-top: 0px;\n        }\n\n        .parameters-table th, .parameters-table td {\n            border-top: 1.2px solid #a6a6a6;\n            border-bottom: 1.2px solid #a6a6a6;\n            border-left: none;\n            border-right: none;\n            padding: 5px 2px;\n            text-align: left;\n            font-size: 16px;\n            line-height: 16px;\n        }\n\n        .parameters-table th {\n            background-color: #f2f2f2;\n            color: #2c2c2c;\n            font-weight: bold;\n        }\n\n        .parameters-table .bg-gray {\n            background-color: #f2f2f2;\n        }\n\n        .options-table-wrapper {\n            overflow-x: auto;\n            -webkit-overflow-scrolling: touch;\n            margin-top: 0px;\n        }\n\n        .options-table {\n            width: 100%;\n            min-width: 1000px;\n            border-collapse: collapse;\n            margin-top: 0px;\n            box-shadow: 0 6px 25px rgba(0, 0, 0, 0.1);\n        }\n\n        .options-table th, .options-table td {\n            border: 2px solid #000;\n            padding: 5px 2px;\n            text-align: center;\n            font-size: 16px;\n            line-height: 16px;\n        }\n\n        .options-table th {\n            background-color: #f2f2f2;\n            color: #2c2c2c;\n            font-weight: bold;\n        }\n\n        .parameters-table2 {\n            width: 100%;\n            min-width: 1000px;\n            border-collapse: collapse;\n            margin-top: 0px;\n        }\n\n        .parameters-table2 th, .parameters-table2 td {\n            border-top: 1.2px solid #a6a6a6;\n            border-bottom: 1.2px solid #a6a6a6;\n            border-left: none;\n            border-right: none;\n            padding: 5px 2px;\n            text-align: center;\n            font-size: 16px;\n            line-height: 16px;\n        }\n\n        .parameters-table2 th {\n            background-color: #f2f2f2;\n            color: #2c2c2c;\n            font-weight: bold;\n        }\n\n        .parameters-table2 .bg-gray {\n            background-color: #f2f2f2;\n        }\n\n        .options-table-wrapper2 {\n            overflow-x: auto;\n            -webkit-overflow-scrolling: touch;\n            margin-top: 0px;\n        }\n\n        .instruction-container {\n            display: flex;\n            justify-content: space-between;\n            align-items: flex-start;\n            gap: 10px;\n            margin-bottom: 0px;\n        }\n\n        .img-container {\n            width: 35%;\n            display: flex;\n            justify-content: center;\n        }\n\n        .text-container {\n            width: 65%;\n            font-size: 16px;\n            font-family: Arial;\n        }\n\n        .instruction-container2 {\n            display: flex;\n            justify-content: space-between;\n            align-items: flex-start;\n            gap: 10px;\n            margin-bottom: 0px;\n        }\n\n        .img-container2 {\n            width: 50%;\n            display: flex;\n            justify-content: center;\n        }\n\n        .text-container2 {\n            width: 50%;\n            display: flex;\n            justify-content: center;\n        }\n\n        @media (max-width: 768px) {\n            .parameters-table th, .parameters-table td {\n                font-size: 14px;\n                padding: 8px 4px;\n            }\n\n            .options-table th, .options-table td {\n                font-size: 14px;\n                padding: 8px 4px;\n            }\n\n            .parameters-table-wrapper {\n                overflow-x: auto;\n            }\n\n            .parameters-table2 th, .parameters-table2 td {\n                font-size: 14px;\n                padding: 8px 4px;\n            }\n\n            .parameters-table-wrapper2 {\n                overflow-x: auto;\n            }\n\n            .desktop-img {\n                display: none;\n            }\n\n            .mobile-img {\n                display: block;\n            }\n\n            .instruction-container {\n                flex-direction: column;\n                align-items: center;\n            }\n\n            .img-container, .text-container {\n                width: 100%;\n                margin-bottom: 0px;\n            }\n\n            .instruction-container2 {\n                flex-direction: column;\n                align-items: center;\n            }\n\n            .img-container2, .text-container2 {\n                width: 100%;\n                margin-bottom: 0px;\n            }\n        }\n\n        @media (max-width: 480px) {\n            .parameters-table th, .parameters-table td {\n                font-size: 12px;\n                padding: 6px 3px;\n            }\n\n            .options-table th, .options-table td {\n                font-size: 12px;\n            }\n\n            .parameters-table-wrapper {\n                overflow-x: auto;\n            }\n\n            .parameters-table2 th, .parameters-table2 td {\n                font-size: 12px;\n                padding: 6px 3px;\n            }\n\n            .parameters-table-wrapper2 {\n                overflow-x: auto;\n            }\n\n            .desktop-img {\n                display: none;\n            }\n\n            .mobile-img {\n                display: block;\n            }\n\n            .instruction-container {\n                flex-direction: column;\n            }\n\n            .instruction-container2 {\n                flex-direction: column;\n            }\n        }\n\n    \u003c\/style\u003e\n\n\u003c!-- Background --\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/UPVC3\/b-s.jpg\" class=\"desktop-img\" alt=\"Desktop Image 1\"\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/UPVC3\/b-s-p.jpg\" class=\"mobile-img\" alt=\"Mobile Image 1\"\u003e\n\u003c!-- Introduction - 2-Wire Auto Return \/ Standard --\u003e\n\u003cdiv\u003e\n    \u003ch2 class=\"section-title\"\u003eIntroduction\u003c\/h2\u003e\n    \u003cp class=\"section-description\"\u003e\n        This \u003cstrong\u003e\u003cu\u003eUPVC 3-way\u003c\/u\u003e\u003c\/strong\u003e motorized ball valve series provides an alternative solution to our standard brass\/stainless steel threaded ball valves currently available. Distinguished from NPT\/G threaded connections, this series adopts a \u003cstrong\u003e\u003cu\u003eUS standard socket end \u0026amp; union connection\u003c\/u\u003e\u003c\/strong\u003e, balancing stable sealing performance with the convenience of quick disassembly and maintenance. For other connection standards, please contact our customer service.\u003cbr\u003e\n        This model uses a \u003cstrong\u003e\u003cu\u003e2-wire auto return\u003c\/u\u003e\u003c\/strong\u003e control method. Unlike a 2-way valve, the OFF position of a 3-way valve does not simply mean fully closed; instead, the ON and OFF positions correspond to different flow paths. When power is lost, this auto-return model returns to its default OFF flow path. A manual override is also included for use during power outages. All models in this series have EPDM seals for reliable performance.\u003cbr\u003e\n        This 3-way valve series offers L-type and T-type configurations (2 options for T-type: T1\/T2). Please note the distinction when purchasing and refer to the main images for flow path type details.\n    \u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- Applications--\u003e\n     \u003ch2 class=\"section-title2\"\u003eApplications\u003c\/h2\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/UPVC2\/a.jpg\" class=\"desktop-img\" alt=\"Desktop Image 1\"\u003e\n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/UPVC2\/a-p.jpg\" class=\"mobile-img\" alt=\"Desktop Image 2\"\u003e\n\u003c!-- Features - 2-Wire Auto Return \/ 3-Way --\u003e\n\u003cdiv\u003e\n    \u003ch2 class=\"section-title\"\u003eFeatures\u003c\/h2\u003e\n    \u003cul class=\"section-description2\"\u003e\n        \u003cli\u003e\n\u003cstrong\u003eUnion \u0026amp; Socket End:\u003c\/strong\u003e Different from standard NPT\/G threaded connections, it uses socket-gluing for sealing and integrates threaded structures, balancing connection stability with quick disassembly and maintenance needs.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eManual Function:\u003c\/strong\u003e Comes with a hex wrench as standard; allows manual valve operation during power outages. \"O\" = ON, \"S\" = OFF.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eIndicator Window:\u003c\/strong\u003e Built-in engraved marks directly show the valve's ON\/OFF status. External arrow pointing to \"0\" means OFF; pointing to \"90\" means ON.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003ePremium Material:\u003c\/strong\u003e Valve body made of UPVC with EPDM seals, meeting general operating requirements.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003e2-Wire Auto Return:\u003c\/strong\u003e Uses a 2-wire auto-return configuration. For 3-way valves, ON and OFF correspond to different flow paths; when power is lost, the valve automatically returns to its default OFF flow path.\u003c\/li\u003e\n    \u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/UPVC3\/2-Return-L.jpg\" class=\"desktop-img\" alt=\"Desktop Image 1\"\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/UPVC3\/2-Return-L-p.jpg\" class=\"mobile-img\" alt=\"Desktop Image 2\"\u003e\n\u003c!-- User Manual --\u003e\n\u003cdiv\u003e\n    \u003ch2 class=\"section-title\"\u003eUser Manual\u003c\/h2\u003e\n    \u003cp class=\"section-description\"\u003e\n        To learn how to use this product, please refer to the \u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/Manual-%20USS-UPVC-3way.pdf\" target=\"_blank\"\u003euser manual\u003c\/a\u003e.\n    \u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- Technical Data --\u003e\n    \u003ch2 class=\"section-title3\"\u003eTechnical Data\u003c\/h2\u003e \n    \u003cdiv class=\"parameters-table-wrapper\"\u003e\n        \u003ctable class=\"parameters-table\"\u003e\n            \u003ctbody\u003e \n                \u003ctr\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003ePort Size\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003e1\/2\"\u003c\/td\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003eUSS-MSV601\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003ePort\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003e3 Way, L Type\u003c\/td\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eThread\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003eNo Thread\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eConnection\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003eUnion \u0026amp; Socket End\u003c\/td\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eMax Power\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003e36W\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eSocket Inside Diameter\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003e21.3mm (US Standard)\u003c\/td\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eWith Hex Wrench\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003eYes\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eWiring\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003e2-Wire Auto Return\u003c\/td\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eManual Function\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003eYes\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eSignal feedback function\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003eNo\u003c\/td\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eIndicator Window\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003eYes\u003c\/td\u003e\n                \u003c\/tr\u003e\n\n                \u003ctr\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eBody Material\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003eUPVC\u003c\/td\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eNormal Position\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003eDefault OFF Flow Path\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eSeal Material\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003eEPDM\u003c\/td\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eTemp Range (Medium)\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003e33.8℉ to 104℉\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eWorking Voltage\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003eDC 24V\u003c\/td\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eClose\/Open Time\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003e10-12s\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eMax Torque\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003e20 N·m\u003c\/td\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eMax. Pressure\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003e232 psi\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eLife Expectancy\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003e20,000 Cycles\u003c\/td\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eIP Rating\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003eIP65\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003ePackage Size\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003e9.1\"×7.1\"×4.7\"\u003c\/td\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eGross Weight\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003e2.9 lb\u003c\/td\u003e\n                \u003c\/tr\u003e \n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n    \u003cp class=\"section-description\"\u003e*To view the full table on mobile, please swipe left or right on the screen.\u003c\/p\u003e\n\u003c!-- Wiring - 2-Wire Auto Return \/ 3-Way --\u003e\n\u003ch2 class=\"section-title\"\u003e2-Wire Auto Return\u003c\/h2\u003e\n\u003cdiv class=\"instruction-container\"\u003e\n    \u003cdiv class=\"img-container\"\u003e\n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Wire\/return.jpg\" alt=\"\" style=\"width: 100%; height: auto;\"\u003e\n    \u003c\/div\u003e\n    \u003cdiv class=\"text-container\"\u003e\n        \u003cp class=\"section-description\"\u003e\n            This model uses a 2-wire auto-return wiring method. For 3-way valves, the ON and OFF positions correspond to different flow paths. When power is applied, the valve switches to the ON flow path; when power is lost or disconnected, it automatically returns to the default OFF flow path.\n        \u003c\/p\u003e\n        \u003cul class=\"section-description2\"\u003e\n            \u003cli\u003eFor the basic version without signal feedback, simply ignore the signal wire connections shown in the diagram.\u003c\/li\u003e\n            \u003cli\u003eWire Color Coding: BK (Black), RD (Red), YW (Yellow), WT (White), BU (Blue), GN (Green), and OG (Orange).\u003c\/li\u003e\n            \u003cli\u003eFor reliable auto-reset performance, power the valve for at least 60 seconds (≥60s) during first commissioning or after a prolonged power cut.\u003c\/li\u003e\n            \u003cli\u003eBefore manual operation, disconnect power and wait briefly for the actuator to discharge.\u003c\/li\u003e\n        \u003c\/ul\u003e\n    \u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- FAQ --\u003e\n\u003cdiv\u003e\n    \u003ch2 class=\"section-title\"\u003eFAQ\u003c\/h2\u003e\n    \u003cp class=\"faq\"\u003e\u003cb\u003eProblem 1: What is unique about the connection method of this ball valve?\u003c\/b\u003e\u003c\/p\u003e\n    \u003cdiv class=\"instruction-container\"\u003e\n        \u003cdiv class=\"img-container\"\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/UPVC2\/size-3.jpg\" alt=\"\" style=\"width: 100%; height: auto;\"\u003e\n        \u003c\/div\u003e\n        \u003cdiv class=\"text-container\"\u003e\n            \u003cp class=\"section-description\"\u003e\n                The larger sizes of our ball valve series (1-1\/4\", 1-1\/2\", and 2\") come standard with \u003cstrong\u003e\u003cu\u003eSocket End ports\u003c\/u\u003e\u003c\/strong\u003e for solvent cement bonding and a \u003cstrong\u003e\u003cu\u003eUnion structure\u003c\/u\u003e\u003c\/strong\u003e for easier installation and maintenance, instead of common threaded connections such as NPT or G.\u003cbr\u003e\n                This union design allows the valve body to be installed or removed more easily for maintenance or replacement, without cutting the pipe or rotating the valve body itself.\u003cbr\u003e\n                The pipe sockets are made to a \u003cstrong\u003e\u003cu\u003eUS standard\u003c\/u\u003e\u003c\/strong\u003e. Please note that the Socket Inside Diameter (I.D.) may vary by national standard even for the same nominal size, such as 1-1\/4\". For other connection standards, including British Standard, Japanese Industrial Standard, or others, please contact our customer service team.\n            \u003c\/p\u003e\n        \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cp class=\"faq\"\u003e\u003cb\u003eProblem 2: Does a 3-way valve have normally open or normally closed status?\u003c\/b\u003e\u003c\/p\u003e\n    \u003cp class=\"section-description\"\u003e\n        For 3-way valves, ON and OFF should be understood as two different flow path positions, rather than simply normally open or normally closed. Each ON\/OFF position corresponds to a specific flow path. For auto-return models, the valve returns to its default OFF flow path when power is lost.\n    \u003c\/p\u003e\n\n    \u003cp class=\"faq\"\u003e\u003cb\u003eProblem 3: How to choose the correct 3-way flow path type?\u003c\/b\u003e\u003c\/p\u003e\n    \u003cdiv class=\"instruction-container\"\u003e\n        \u003cdiv class=\"img-container\"\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/UPVC3\/flow%20path.png\" alt=\"\" style=\"width: 100%; height: auto;\"\u003e\n        \u003c\/div\u003e\n        \u003cdiv class=\"text-container\"\u003e\n            \u003cp class=\"section-description\"\u003e\n                This 3-way electric ball valve is available in three flow path configurations: \u003cstrong\u003eL-type\u003c\/strong\u003e, \u003cstrong\u003eT-type T1\u003c\/strong\u003e, and \u003cstrong\u003eT-type T2\u003c\/strong\u003e. The diagrams show the corresponding flow path for each configuration when the valve is in the ON and OFF positions.\u003cbr\u003e\n                Please note that ON and OFF each correspond to a different flow path. For wiring instructions specific to your model, please refer to the Wiring Schematics section. A connection such as C-B means the two ports are open to each other, not a fixed flow direction.\n            \u003c\/p\u003e\n        \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cp class=\"faq\"\u003e\u003cb\u003eProblem 4: What precautions apply to auto-return models?\u003c\/b\u003e\u003c\/p\u003e\n    \u003cp class=\"section-description\"\u003e\n        The auto-return ball valve requires a minimum power-on duration of 60 seconds (≥60s). This step is mandatory during first commissioning or after a prolonged power cut to ensure reliable auto-reset performance. Before using the manual override, always disconnect the power first. For auto-return models, please wait for a short period after power is disconnected before manual operation, as the actuator needs time to discharge; otherwise, the valve may be difficult to turn manually.\n    \u003c\/p\u003e\n\n    \u003cp class=\"faq\"\u003e\u003cb\u003eProblem 5: Does this model come with a manual function?\u003c\/b\u003e\u003c\/p\u003e\n    \u003cp class=\"section-description\"\u003e\n        \u003cstrong\u003eYes.\u003c\/strong\u003e The manual override function allows you to control the valve position during a power outage. A hexagonal wrench is included with the valve for this purpose.\u003cbr\u003e\n        Power must be disconnected before manual operation. Turn the valve according to the \"O\" and \"S\" indicators: \"O\" = ON, \"S\" = OFF. The valve should be turned fully to the ON or OFF position; do not leave it in a middle position, as this may damage the valve. For auto-return models, wait for a short period after disconnecting power before manual operation.\n    \u003c\/p\u003e\n\n    \u003cp class=\"faq\"\u003e\u003cb\u003eProblem 6: How to read the indicator window?\u003c\/b\u003e\u003c\/p\u003e\n    \u003cp class=\"section-description\"\u003e\n        The external arrow shows the valve position. When the arrow points to \"0\", the valve is in the OFF position; when it points to \"90\", the valve is in the ON position.\n    \u003c\/p\u003e\n\n    \u003cp class=\"faq\"\u003e\u003cb\u003eProblem 7: What is a Union connection?\u003c\/b\u003e\u003c\/p\u003e\n    \u003cp class=\"section-description\"\u003e\n        A Union connection is a detachable valve structure that allows the valve body to be removed more easily for maintenance or replacement without cutting the pipe. On this product, the pipe connection ends are Socket End ports designed for solvent cement bonding.\n    \u003c\/p\u003e\n\n    \u003cp class=\"faq\"\u003e\u003cb\u003eProblem 8: What should be noted about the four main control methods?\u003c\/b\u003e\u003c\/p\u003e\n    \u003cp class=\"section-description\"\u003e\n        Please pay attention to the wiring type when purchasing. Only auto-return models will automatically return to the default OFF flow path when power is lost. Other control methods do not automatically reset after power loss and will remain in their current flow path.\n    \u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/body\u003e","brand":"U.S. Solid","offers":[{"title":"Default Title","offer_id":47870941004031,"sku":"JFMSV00601","price":257.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/1_c10be6d7-b18f-4915-a3f4-b1191fc2533c.jpg?v=1765848983"},{"product_id":"upvc-3-way-motorized-ball-valve-t1-type-union-socket-end-2-wire-auto-return-dc-24v-with-manual-override","title":"1\/2\" UPVC 3-Way Motorized Ball Valve (T1 Type), Union \u0026 Socket End, 2 Wire Auto Return, DC 24V, with Manual Override","description":"\u003cbody\u003e\n    \u003cmeta charset=\"UTF-8\"\u003e\n    \u003cmeta name=\"viewport\" content=\"width=device-width, initial-scale=1.0\"\u003e\n    \u003ctitle\u003eResponsive Page with Multiple Modules\u003c\/title\u003e\n    \u003cstyle\u003e\n\n        .desktop-img {\n            display: block;\n        }\n        .mobile-img {\n            display: none;\n        }\n\n        .section-title {\n            font-size: 22px;\n            line-height: 22px;\n            font-weight: bold;\n            margin: 15px 0 5px;\n            font-family: Arial;\n        }\n\n        .section-title2 {\n            font-size: 22px;\n            line-height: 22px;\n            font-weight: bold;\n            margin: 15px 0 3px;\n            font-family: Arial;\n        }\n\n        .section-title3 {\n            font-size: 22px;\n            line-height: 22px;\n            font-weight: bold;\n            margin: 15px 0 10px;\n            font-family: Arial;\n        }\n\n        .section-description {\n            font-size: 16px;\n            line-height: 26px;\n            margin-top: 0px;\n            margin-bottom: 5px;\n            font-family: Arial;\n        }\n\n        .faq {\n            font-size: 16px;\n            margin: 0;\n            line-height: 26px;\n            background-color: #f2f2f2;\n            padding: 5px;\n        }\n\n        .section-description2 {\n            font-size: 16px;\n            line-height: 26px;\n            margin: 0px;\n            font-family: Arial;\n        }\n\n        .parameters-table-wrapper {\n            overflow-x: auto;\n            -webkit-overflow-scrolling: touch;\n            margin-top: 0px;\n        }\n\n        .parameters-table {\n            width: 100%;\n            min-width: 1000px;\n            border-collapse: collapse;\n            margin-top: 0px;\n        }\n\n        .parameters-table th, .parameters-table td {\n            border-top: 1.2px solid #a6a6a6;\n            border-bottom: 1.2px solid #a6a6a6;\n            border-left: none;\n            border-right: none;\n            padding: 5px 2px;\n            text-align: left;\n            font-size: 16px;\n            line-height: 16px;\n        }\n\n        .parameters-table th {\n            background-color: #f2f2f2;\n            color: #2c2c2c;\n            font-weight: bold;\n        }\n\n        .parameters-table .bg-gray {\n            background-color: #f2f2f2;\n        }\n\n        .options-table-wrapper {\n            overflow-x: auto;\n            -webkit-overflow-scrolling: touch;\n            margin-top: 0px;\n        }\n\n        .options-table {\n            width: 100%;\n            min-width: 1000px;\n            border-collapse: collapse;\n            margin-top: 0px;\n            box-shadow: 0 6px 25px rgba(0, 0, 0, 0.1);\n        }\n\n        .options-table th, .options-table td {\n            border: 2px solid #000;\n            padding: 5px 2px;\n            text-align: center;\n            font-size: 16px;\n            line-height: 16px;\n        }\n\n        .options-table th {\n            background-color: #f2f2f2;\n            color: #2c2c2c;\n            font-weight: bold;\n        }\n\n        .parameters-table2 {\n            width: 100%;\n            min-width: 1000px;\n            border-collapse: collapse;\n            margin-top: 0px;\n        }\n\n        .parameters-table2 th, .parameters-table2 td {\n            border-top: 1.2px solid #a6a6a6;\n            border-bottom: 1.2px solid #a6a6a6;\n            border-left: none;\n            border-right: none;\n            padding: 5px 2px;\n            text-align: center;\n            font-size: 16px;\n            line-height: 16px;\n        }\n\n        .parameters-table2 th {\n            background-color: #f2f2f2;\n            color: #2c2c2c;\n            font-weight: bold;\n        }\n\n        .parameters-table2 .bg-gray {\n            background-color: #f2f2f2;\n        }\n\n        .options-table-wrapper2 {\n            overflow-x: auto;\n            -webkit-overflow-scrolling: touch;\n            margin-top: 0px;\n        }\n\n        .instruction-container {\n            display: flex;\n            justify-content: space-between;\n            align-items: flex-start;\n            gap: 10px;\n            margin-bottom: 0px;\n        }\n\n        .img-container {\n            width: 35%;\n            display: flex;\n            justify-content: center;\n        }\n\n        .text-container {\n            width: 65%;\n            font-size: 16px;\n            font-family: Arial;\n        }\n\n        .instruction-container2 {\n            display: flex;\n            justify-content: space-between;\n            align-items: flex-start;\n            gap: 10px;\n            margin-bottom: 0px;\n        }\n\n        .img-container2 {\n            width: 50%;\n            display: flex;\n            justify-content: center;\n        }\n\n        .text-container2 {\n            width: 50%;\n            display: flex;\n            justify-content: center;\n        }\n\n        @media (max-width: 768px) {\n            .parameters-table th, .parameters-table td {\n                font-size: 14px;\n                padding: 8px 4px;\n            }\n\n            .options-table th, .options-table td {\n                font-size: 14px;\n                padding: 8px 4px;\n            }\n\n            .parameters-table-wrapper {\n                overflow-x: auto;\n            }\n\n            .parameters-table2 th, .parameters-table2 td {\n                font-size: 14px;\n                padding: 8px 4px;\n            }\n\n            .parameters-table-wrapper2 {\n                overflow-x: auto;\n            }\n\n            .desktop-img {\n                display: none;\n            }\n\n            .mobile-img {\n                display: block;\n            }\n\n            .instruction-container {\n                flex-direction: column;\n                align-items: center;\n            }\n\n            .img-container, .text-container {\n                width: 100%;\n                margin-bottom: 0px;\n            }\n\n            .instruction-container2 {\n                flex-direction: column;\n                align-items: center;\n            }\n\n            .img-container2, .text-container2 {\n                width: 100%;\n                margin-bottom: 0px;\n            }\n        }\n\n        @media (max-width: 480px) {\n            .parameters-table th, .parameters-table td {\n                font-size: 12px;\n                padding: 6px 3px;\n            }\n\n            .options-table th, .options-table td {\n                font-size: 12px;\n            }\n\n            .parameters-table-wrapper {\n                overflow-x: auto;\n            }\n\n            .parameters-table2 th, .parameters-table2 td {\n                font-size: 12px;\n                padding: 6px 3px;\n            }\n\n            .parameters-table-wrapper2 {\n                overflow-x: auto;\n            }\n\n            .desktop-img {\n                display: none;\n            }\n\n            .mobile-img {\n                display: block;\n            }\n\n            .instruction-container {\n                flex-direction: column;\n            }\n\n            .instruction-container2 {\n                flex-direction: column;\n            }\n        }\n\n    \u003c\/style\u003e\n\n\u003c!-- Background --\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/UPVC3\/b-s.jpg\" class=\"desktop-img\" alt=\"Desktop Image 1\"\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/UPVC3\/b-s-p.jpg\" class=\"mobile-img\" alt=\"Mobile Image 1\"\u003e\n\u003c!-- Introduction - 2-Wire Auto Return \/ Standard --\u003e\n\u003cdiv\u003e\n    \u003ch2 class=\"section-title\"\u003eIntroduction\u003c\/h2\u003e\n    \u003cp class=\"section-description\"\u003e\n        This \u003cstrong\u003e\u003cu\u003eUPVC 3-way\u003c\/u\u003e\u003c\/strong\u003e motorized ball valve series provides an alternative solution to our standard brass\/stainless steel threaded ball valves currently available. Distinguished from NPT\/G threaded connections, this series adopts a \u003cstrong\u003e\u003cu\u003eUS standard socket end \u0026amp; union connection\u003c\/u\u003e\u003c\/strong\u003e, balancing stable sealing performance with the convenience of quick disassembly and maintenance. For other connection standards, please contact our customer service.\u003cbr\u003e\n        This model uses a \u003cstrong\u003e\u003cu\u003e2-wire auto return\u003c\/u\u003e\u003c\/strong\u003e control method. Unlike a 2-way valve, the OFF position of a 3-way valve does not simply mean fully closed; instead, the ON and OFF positions correspond to different flow paths. When power is lost, this auto-return model returns to its default OFF flow path. A manual override is also included for use during power outages. All models in this series have EPDM seals for reliable performance.\u003cbr\u003e\n        This 3-way valve series offers L-type and T-type configurations (2 options for T-type: T1\/T2). Please note the distinction when purchasing and refer to the main images for flow path type details.\n    \u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- Applications--\u003e\n     \u003ch2 class=\"section-title2\"\u003eApplications\u003c\/h2\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/UPVC2\/a.jpg\" class=\"desktop-img\" alt=\"Desktop Image 1\"\u003e\n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/UPVC2\/a-p.jpg\" class=\"mobile-img\" alt=\"Desktop Image 2\"\u003e\n\u003c!-- Features - 2-Wire Auto Return \/ 3-Way --\u003e\n\u003cdiv\u003e\n    \u003ch2 class=\"section-title\"\u003eFeatures\u003c\/h2\u003e\n    \u003cul class=\"section-description2\"\u003e\n        \u003cli\u003e\n\u003cstrong\u003eUnion \u0026amp; Socket End:\u003c\/strong\u003e Different from standard NPT\/G threaded connections, it uses socket-gluing for sealing and integrates threaded structures, balancing connection stability with quick disassembly and maintenance needs.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eManual Function:\u003c\/strong\u003e Comes with a hex wrench as standard; allows manual valve operation during power outages. \"O\" = ON, \"S\" = OFF.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eIndicator Window:\u003c\/strong\u003e Built-in engraved marks directly show the valve's ON\/OFF status. External arrow pointing to \"0\" means OFF; pointing to \"90\" means ON.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003ePremium Material:\u003c\/strong\u003e Valve body made of UPVC with EPDM seals, meeting general operating requirements.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003e2-Wire Auto Return:\u003c\/strong\u003e Uses a 2-wire auto-return configuration. For 3-way valves, ON and OFF correspond to different flow paths; when power is lost, the valve automatically returns to its default OFF flow path.\u003c\/li\u003e\n    \u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/UPVC3\/2-Return-T1.jpg\" class=\"desktop-img\" alt=\"Desktop Image 1\"\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/UPVC3\/2-Return-T1-p.jpg\" class=\"mobile-img\" alt=\"Desktop Image 2\"\u003e\n\u003c!-- User Manual --\u003e\n\u003cdiv\u003e\n    \u003ch2 class=\"section-title\"\u003eUser Manual\u003c\/h2\u003e\n    \u003cp class=\"section-description\"\u003e\n        To learn how to use this product, please refer to the \u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/Manual-%20USS-UPVC-3way.pdf\" target=\"_blank\"\u003euser manual\u003c\/a\u003e.\n    \u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- Technical Data --\u003e\n    \u003ch2 class=\"section-title3\"\u003eTechnical Data\u003c\/h2\u003e \n    \u003cdiv class=\"parameters-table-wrapper\"\u003e\n        \u003ctable class=\"parameters-table\"\u003e\n            \u003ctbody\u003e \n                \u003ctr\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003ePort Size\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003e1\/2\"\u003c\/td\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003eUSS-MSV606\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003ePort\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003e3 Way, T1 Type\u003c\/td\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eThread\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003eNo Thread\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eConnection\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003eUnion \u0026amp; Socket End\u003c\/td\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eMax Power\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003e36W\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eSocket Inside Diameter\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003e21.3mm (US Standard)\u003c\/td\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eWith Hex Wrench\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003eYes\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eWiring\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003e2-Wire Auto Return\u003c\/td\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eManual Function\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003eYes\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eSignal feedback function\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003eNo\u003c\/td\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eIndicator Window\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003eYes\u003c\/td\u003e\n                \u003c\/tr\u003e\n\n                \u003ctr\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eBody Material\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003eUPVC\u003c\/td\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eNormal Position\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003eDefault OFF Flow Path\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eSeal Material\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003eEPDM\u003c\/td\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eTemp Range (Medium)\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003e33.8℉ to 104℉\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eWorking Voltage\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003eDC 24V\u003c\/td\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eClose\/Open Time\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003e10-12s\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eMax Torque\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003e20 N·m\u003c\/td\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eMax. Pressure\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003e232 psi\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eLife Expectancy\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003e20,000 Cycles\u003c\/td\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eIP Rating\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003eIP65\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003ePackage Size\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003e9.1\"×7.1\"×4.7\"\u003c\/td\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eGross Weight\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003e2.9 lb\u003c\/td\u003e\n                \u003c\/tr\u003e \n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n    \u003cp class=\"section-description\"\u003e*To view the full table on mobile, please swipe left or right on the screen.\u003c\/p\u003e\n\u003c!-- Wiring - 2-Wire Auto Return \/ 3-Way --\u003e\n\u003ch2 class=\"section-title\"\u003e2-Wire Auto Return\u003c\/h2\u003e\n\u003cdiv class=\"instruction-container\"\u003e\n    \u003cdiv class=\"img-container\"\u003e\n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Wire\/return.jpg\" alt=\"\" style=\"width: 100%; height: auto;\"\u003e\n    \u003c\/div\u003e\n    \u003cdiv class=\"text-container\"\u003e\n        \u003cp class=\"section-description\"\u003e\n            This model uses a 2-wire auto-return wiring method. For 3-way valves, the ON and OFF positions correspond to different flow paths. When power is applied, the valve switches to the ON flow path; when power is lost or disconnected, it automatically returns to the default OFF flow path.\n        \u003c\/p\u003e\n        \u003cul class=\"section-description2\"\u003e\n            \u003cli\u003eFor the basic version without signal feedback, simply ignore the signal wire connections shown in the diagram.\u003c\/li\u003e\n            \u003cli\u003eWire Color Coding: BK (Black), RD (Red), YW (Yellow), WT (White), BU (Blue), GN (Green), and OG (Orange).\u003c\/li\u003e\n            \u003cli\u003eFor reliable auto-reset performance, power the valve for at least 60 seconds (≥60s) during first commissioning or after a prolonged power cut.\u003c\/li\u003e\n            \u003cli\u003eBefore manual operation, disconnect power and wait briefly for the actuator to discharge.\u003c\/li\u003e\n        \u003c\/ul\u003e\n    \u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- FAQ --\u003e\n\u003cdiv\u003e\n    \u003ch2 class=\"section-title\"\u003eFAQ\u003c\/h2\u003e\n    \u003cp class=\"faq\"\u003e\u003cb\u003eProblem 1: What is unique about the connection method of this ball valve?\u003c\/b\u003e\u003c\/p\u003e\n    \u003cdiv class=\"instruction-container\"\u003e\n        \u003cdiv class=\"img-container\"\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/UPVC2\/size-3.jpg\" alt=\"\" style=\"width: 100%; height: auto;\"\u003e\n        \u003c\/div\u003e\n        \u003cdiv class=\"text-container\"\u003e\n            \u003cp class=\"section-description\"\u003e\n                The larger sizes of our ball valve series (1-1\/4\", 1-1\/2\", and 2\") come standard with \u003cstrong\u003e\u003cu\u003eSocket End ports\u003c\/u\u003e\u003c\/strong\u003e for solvent cement bonding and a \u003cstrong\u003e\u003cu\u003eUnion structure\u003c\/u\u003e\u003c\/strong\u003e for easier installation and maintenance, instead of common threaded connections such as NPT or G.\u003cbr\u003e\n                This union design allows the valve body to be installed or removed more easily for maintenance or replacement, without cutting the pipe or rotating the valve body itself.\u003cbr\u003e\n                The pipe sockets are made to a \u003cstrong\u003e\u003cu\u003eUS standard\u003c\/u\u003e\u003c\/strong\u003e. Please note that the Socket Inside Diameter (I.D.) may vary by national standard even for the same nominal size, such as 1-1\/4\". For other connection standards, including British Standard, Japanese Industrial Standard, or others, please contact our customer service team.\n            \u003c\/p\u003e\n        \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cp class=\"faq\"\u003e\u003cb\u003eProblem 2: Does a 3-way valve have normally open or normally closed status?\u003c\/b\u003e\u003c\/p\u003e\n    \u003cp class=\"section-description\"\u003e\n        For 3-way valves, ON and OFF should be understood as two different flow path positions, rather than simply normally open or normally closed. Each ON\/OFF position corresponds to a specific flow path. For auto-return models, the valve returns to its default OFF flow path when power is lost.\n    \u003c\/p\u003e\n\n    \u003cp class=\"faq\"\u003e\u003cb\u003eProblem 3: How to choose the correct 3-way flow path type?\u003c\/b\u003e\u003c\/p\u003e\n    \u003cdiv class=\"instruction-container\"\u003e\n        \u003cdiv class=\"img-container\"\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/UPVC3\/flow%20path.png\" alt=\"\" style=\"width: 100%; height: auto;\"\u003e\n        \u003c\/div\u003e\n        \u003cdiv class=\"text-container\"\u003e\n            \u003cp class=\"section-description\"\u003e\n                This 3-way electric ball valve is available in three flow path configurations: \u003cstrong\u003eL-type\u003c\/strong\u003e, \u003cstrong\u003eT-type T1\u003c\/strong\u003e, and \u003cstrong\u003eT-type T2\u003c\/strong\u003e. The diagrams show the corresponding flow path for each configuration when the valve is in the ON and OFF positions.\u003cbr\u003e\n                Please note that ON and OFF each correspond to a different flow path. For wiring instructions specific to your model, please refer to the Wiring Schematics section. A connection such as C-B means the two ports are open to each other, not a fixed flow direction.\n            \u003c\/p\u003e\n        \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cp class=\"faq\"\u003e\u003cb\u003eProblem 4: What precautions apply to auto-return models?\u003c\/b\u003e\u003c\/p\u003e\n    \u003cp class=\"section-description\"\u003e\n        The auto-return ball valve requires a minimum power-on duration of 60 seconds (≥60s). This step is mandatory during first commissioning or after a prolonged power cut to ensure reliable auto-reset performance. Before using the manual override, always disconnect the power first. For auto-return models, please wait for a short period after power is disconnected before manual operation, as the actuator needs time to discharge; otherwise, the valve may be difficult to turn manually.\n    \u003c\/p\u003e\n\n    \u003cp class=\"faq\"\u003e\u003cb\u003eProblem 5: Does this model come with a manual function?\u003c\/b\u003e\u003c\/p\u003e\n    \u003cp class=\"section-description\"\u003e\n        \u003cstrong\u003eYes.\u003c\/strong\u003e The manual override function allows you to control the valve position during a power outage. A hexagonal wrench is included with the valve for this purpose.\u003cbr\u003e\n        Power must be disconnected before manual operation. Turn the valve according to the \"O\" and \"S\" indicators: \"O\" = ON, \"S\" = OFF. The valve should be turned fully to the ON or OFF position; do not leave it in a middle position, as this may damage the valve. For auto-return models, wait for a short period after disconnecting power before manual operation.\n    \u003c\/p\u003e\n\n    \u003cp class=\"faq\"\u003e\u003cb\u003eProblem 6: How to read the indicator window?\u003c\/b\u003e\u003c\/p\u003e\n    \u003cp class=\"section-description\"\u003e\n        The external arrow shows the valve position. When the arrow points to \"0\", the valve is in the OFF position; when it points to \"90\", the valve is in the ON position.\n    \u003c\/p\u003e\n\n    \u003cp class=\"faq\"\u003e\u003cb\u003eProblem 7: What is a Union connection?\u003c\/b\u003e\u003c\/p\u003e\n    \u003cp class=\"section-description\"\u003e\n        A Union connection is a detachable valve structure that allows the valve body to be removed more easily for maintenance or replacement without cutting the pipe. On this product, the pipe connection ends are Socket End ports designed for solvent cement bonding.\n    \u003c\/p\u003e\n\n    \u003cp class=\"faq\"\u003e\u003cb\u003eProblem 8: What should be noted about the four main control methods?\u003c\/b\u003e\u003c\/p\u003e\n    \u003cp class=\"section-description\"\u003e\n        Please pay attention to the wiring type when purchasing. Only auto-return models will automatically return to the default OFF flow path when power is lost. Other control methods do not automatically reset after power loss and will remain in their current flow path.\n    \u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/body\u003e","brand":"U.S. Solid","offers":[{"title":"Default Title","offer_id":47870946279679,"sku":"JFMSV00606","price":257.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/1_b37f5053-7124-43d2-949b-740de7308b8d.jpg?v=1765849031"},{"product_id":"upvc-3-way-motorized-ball-valve-t2-type-union-socket-end-2-wire-auto-return-dc-24v-with-manual-override","title":"1\/2\" UPVC 3-Way Motorized Ball Valve (T2 Type), Union \u0026 Socket End, 2 Wire Auto Return, DC 24V, with Manual Override","description":"\u003cbody\u003e\n    \u003cmeta charset=\"UTF-8\"\u003e\n    \u003cmeta name=\"viewport\" content=\"width=device-width, initial-scale=1.0\"\u003e\n    \u003ctitle\u003eResponsive Page with Multiple Modules\u003c\/title\u003e\n    \u003cstyle\u003e\n\n        .desktop-img {\n            display: block;\n        }\n        .mobile-img {\n            display: none;\n        }\n\n        .section-title {\n            font-size: 22px;\n            line-height: 22px;\n            font-weight: bold;\n            margin: 15px 0 5px;\n            font-family: Arial;\n        }\n\n        .section-title2 {\n            font-size: 22px;\n            line-height: 22px;\n            font-weight: bold;\n            margin: 15px 0 3px;\n            font-family: Arial;\n        }\n\n        .section-title3 {\n            font-size: 22px;\n            line-height: 22px;\n            font-weight: bold;\n            margin: 15px 0 10px;\n            font-family: Arial;\n        }\n\n        .section-description {\n            font-size: 16px;\n            line-height: 26px;\n            margin-top: 0px;\n            margin-bottom: 5px;\n            font-family: Arial;\n        }\n\n        .faq {\n            font-size: 16px;\n            margin: 0;\n            line-height: 26px;\n            background-color: #f2f2f2;\n            padding: 5px;\n        }\n\n        .section-description2 {\n            font-size: 16px;\n            line-height: 26px;\n            margin: 0px;\n            font-family: Arial;\n        }\n\n        .parameters-table-wrapper {\n            overflow-x: auto;\n            -webkit-overflow-scrolling: touch;\n            margin-top: 0px;\n        }\n\n        .parameters-table {\n            width: 100%;\n            min-width: 1000px;\n            border-collapse: collapse;\n            margin-top: 0px;\n        }\n\n        .parameters-table th, .parameters-table td {\n            border-top: 1.2px solid #a6a6a6;\n            border-bottom: 1.2px solid #a6a6a6;\n            border-left: none;\n            border-right: none;\n            padding: 5px 2px;\n            text-align: left;\n            font-size: 16px;\n            line-height: 16px;\n        }\n\n        .parameters-table th {\n            background-color: #f2f2f2;\n            color: #2c2c2c;\n            font-weight: bold;\n        }\n\n        .parameters-table .bg-gray {\n            background-color: #f2f2f2;\n        }\n\n        .options-table-wrapper {\n            overflow-x: auto;\n            -webkit-overflow-scrolling: touch;\n            margin-top: 0px;\n        }\n\n        .options-table {\n            width: 100%;\n            min-width: 1000px;\n            border-collapse: collapse;\n            margin-top: 0px;\n            box-shadow: 0 6px 25px rgba(0, 0, 0, 0.1);\n        }\n\n        .options-table th, .options-table td {\n            border: 2px solid #000;\n            padding: 5px 2px;\n            text-align: center;\n            font-size: 16px;\n            line-height: 16px;\n        }\n\n        .options-table th {\n            background-color: #f2f2f2;\n            color: #2c2c2c;\n            font-weight: bold;\n        }\n\n        .parameters-table2 {\n            width: 100%;\n            min-width: 1000px;\n            border-collapse: collapse;\n            margin-top: 0px;\n        }\n\n        .parameters-table2 th, .parameters-table2 td {\n            border-top: 1.2px solid #a6a6a6;\n            border-bottom: 1.2px solid #a6a6a6;\n            border-left: none;\n            border-right: none;\n            padding: 5px 2px;\n            text-align: center;\n            font-size: 16px;\n            line-height: 16px;\n        }\n\n        .parameters-table2 th {\n            background-color: #f2f2f2;\n            color: #2c2c2c;\n            font-weight: bold;\n        }\n\n        .parameters-table2 .bg-gray {\n            background-color: #f2f2f2;\n        }\n\n        .options-table-wrapper2 {\n            overflow-x: auto;\n            -webkit-overflow-scrolling: touch;\n            margin-top: 0px;\n        }\n\n        .instruction-container {\n            display: flex;\n            justify-content: space-between;\n            align-items: flex-start;\n            gap: 10px;\n            margin-bottom: 0px;\n        }\n\n        .img-container {\n            width: 35%;\n            display: flex;\n            justify-content: center;\n        }\n\n        .text-container {\n            width: 65%;\n            font-size: 16px;\n            font-family: Arial;\n        }\n\n        .instruction-container2 {\n            display: flex;\n            justify-content: space-between;\n            align-items: flex-start;\n            gap: 10px;\n            margin-bottom: 0px;\n        }\n\n        .img-container2 {\n            width: 50%;\n            display: flex;\n            justify-content: center;\n        }\n\n        .text-container2 {\n            width: 50%;\n            display: flex;\n            justify-content: center;\n        }\n\n        @media (max-width: 768px) {\n            .parameters-table th, .parameters-table td {\n                font-size: 14px;\n                padding: 8px 4px;\n            }\n\n            .options-table th, .options-table td {\n                font-size: 14px;\n                padding: 8px 4px;\n            }\n\n            .parameters-table-wrapper {\n                overflow-x: auto;\n            }\n\n            .parameters-table2 th, .parameters-table2 td {\n                font-size: 14px;\n                padding: 8px 4px;\n            }\n\n            .parameters-table-wrapper2 {\n                overflow-x: auto;\n            }\n\n            .desktop-img {\n                display: none;\n            }\n\n            .mobile-img {\n                display: block;\n            }\n\n            .instruction-container {\n                flex-direction: column;\n                align-items: center;\n            }\n\n            .img-container, .text-container {\n                width: 100%;\n                margin-bottom: 0px;\n            }\n\n            .instruction-container2 {\n                flex-direction: column;\n                align-items: center;\n            }\n\n            .img-container2, .text-container2 {\n                width: 100%;\n                margin-bottom: 0px;\n            }\n        }\n\n        @media (max-width: 480px) {\n            .parameters-table th, .parameters-table td {\n                font-size: 12px;\n                padding: 6px 3px;\n            }\n\n            .options-table th, .options-table td {\n                font-size: 12px;\n            }\n\n            .parameters-table-wrapper {\n                overflow-x: auto;\n            }\n\n            .parameters-table2 th, .parameters-table2 td {\n                font-size: 12px;\n                padding: 6px 3px;\n            }\n\n            .parameters-table-wrapper2 {\n                overflow-x: auto;\n            }\n\n            .desktop-img {\n                display: none;\n            }\n\n            .mobile-img {\n                display: block;\n            }\n\n            .instruction-container {\n                flex-direction: column;\n            }\n\n            .instruction-container2 {\n                flex-direction: column;\n            }\n        }\n\n    \u003c\/style\u003e\n\n\u003c!-- Background --\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/UPVC3\/b-s.jpg\" class=\"desktop-img\" alt=\"Desktop Image 1\"\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/UPVC3\/b-s-p.jpg\" class=\"mobile-img\" alt=\"Mobile Image 1\"\u003e\n\u003c!-- Introduction - 2-Wire Auto Return \/ Standard --\u003e\n\u003cdiv\u003e\n    \u003ch2 class=\"section-title\"\u003eIntroduction\u003c\/h2\u003e\n    \u003cp class=\"section-description\"\u003e\n        This \u003cstrong\u003e\u003cu\u003eUPVC 3-way\u003c\/u\u003e\u003c\/strong\u003e motorized ball valve series provides an alternative solution to our standard brass\/stainless steel threaded ball valves currently available. Distinguished from NPT\/G threaded connections, this series adopts a \u003cstrong\u003e\u003cu\u003eUS standard socket end \u0026amp; union connection\u003c\/u\u003e\u003c\/strong\u003e, balancing stable sealing performance with the convenience of quick disassembly and maintenance. For other connection standards, please contact our customer service.\u003cbr\u003e\n        This model uses a \u003cstrong\u003e\u003cu\u003e2-wire auto return\u003c\/u\u003e\u003c\/strong\u003e control method. Unlike a 2-way valve, the OFF position of a 3-way valve does not simply mean fully closed; instead, the ON and OFF positions correspond to different flow paths. When power is lost, this auto-return model returns to its default OFF flow path. A manual override is also included for use during power outages. All models in this series have EPDM seals for reliable performance.\u003cbr\u003e\n        This 3-way valve series offers L-type and T-type configurations (2 options for T-type: T1\/T2). Please note the distinction when purchasing and refer to the main images for flow path type details.\n    \u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- Applications--\u003e\n     \u003ch2 class=\"section-title2\"\u003eApplications\u003c\/h2\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/UPVC2\/a.jpg\" class=\"desktop-img\" alt=\"Desktop Image 1\"\u003e\n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/UPVC2\/a-p.jpg\" class=\"mobile-img\" alt=\"Desktop Image 2\"\u003e\n\u003c!-- Features - 2-Wire Auto Return \/ 3-Way --\u003e\n\u003cdiv\u003e\n    \u003ch2 class=\"section-title\"\u003eFeatures\u003c\/h2\u003e\n    \u003cul class=\"section-description2\"\u003e\n        \u003cli\u003e\n\u003cstrong\u003eUnion \u0026amp; Socket End:\u003c\/strong\u003e Different from standard NPT\/G threaded connections, it uses socket-gluing for sealing and integrates threaded structures, balancing connection stability with quick disassembly and maintenance needs.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eManual Function:\u003c\/strong\u003e Comes with a hex wrench as standard; allows manual valve operation during power outages. \"O\" = ON, \"S\" = OFF.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eIndicator Window:\u003c\/strong\u003e Built-in engraved marks directly show the valve's ON\/OFF status. External arrow pointing to \"0\" means OFF; pointing to \"90\" means ON.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003ePremium Material:\u003c\/strong\u003e Valve body made of UPVC with EPDM seals, meeting general operating requirements.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003e2-Wire Auto Return:\u003c\/strong\u003e Uses a 2-wire auto-return configuration. For 3-way valves, ON and OFF correspond to different flow paths; when power is lost, the valve automatically returns to its default OFF flow path.\u003c\/li\u003e\n    \u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/UPVC3\/2-Return-T2.jpg\" class=\"desktop-img\" alt=\"Desktop Image 1\"\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/UPVC3\/2-Return-T2-p.jpg\" class=\"mobile-img\" alt=\"Desktop Image 2\"\u003e\n\u003c!-- User Manual --\u003e\n\u003cdiv\u003e\n    \u003ch2 class=\"section-title\"\u003eUser Manual\u003c\/h2\u003e\n    \u003cp class=\"section-description\"\u003e\n        To learn how to use this product, please refer to the \u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/Manual-%20USS-UPVC-3way.pdf\" target=\"_blank\"\u003euser manual\u003c\/a\u003e.\n    \u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- Technical Data --\u003e\n    \u003ch2 class=\"section-title3\"\u003eTechnical Data\u003c\/h2\u003e \n    \u003cdiv class=\"parameters-table-wrapper\"\u003e\n        \u003ctable class=\"parameters-table\"\u003e\n            \u003ctbody\u003e \n                \u003ctr\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003ePort Size\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003e1\/2\"\u003c\/td\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003eUSS-MSV611\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003ePort\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003e3 Way, T2 Type\u003c\/td\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eThread\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003eNo Thread\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eConnection\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003eUnion \u0026amp; Socket End\u003c\/td\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eMax Power\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003e36W\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eSocket Inside Diameter\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003e21.3mm (US Standard)\u003c\/td\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eWith Hex Wrench\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003eYes\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eWiring\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003e2-Wire Auto Return\u003c\/td\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eManual Function\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003eYes\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eSignal feedback function\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003eNo\u003c\/td\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eIndicator Window\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003eYes\u003c\/td\u003e\n                \u003c\/tr\u003e\n\n                \u003ctr\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eBody Material\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003eUPVC\u003c\/td\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eNormal Position\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003eDefault OFF Flow Path\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eSeal Material\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003eEPDM\u003c\/td\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eTemp Range (Medium)\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003e33.8℉ to 104℉\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eWorking Voltage\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003eDC 24V\u003c\/td\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eClose\/Open Time\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003e10-12s\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eMax Torque\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003e20 N·m\u003c\/td\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eMax. Pressure\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003e232 psi\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eLife Expectancy\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003e20,000 Cycles\u003c\/td\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eIP Rating\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003eIP65\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003ePackage Size\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003e9.1\"×7.1\"×4.7\"\u003c\/td\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eGross Weight\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003e2.9 lb\u003c\/td\u003e\n                \u003c\/tr\u003e \n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n    \u003cp class=\"section-description\"\u003e*To view the full table on mobile, please swipe left or right on the screen.\u003c\/p\u003e\n\u003c!-- Wiring - 2-Wire Auto Return \/ 3-Way --\u003e\n\u003ch2 class=\"section-title\"\u003e2-Wire Auto Return\u003c\/h2\u003e\n\u003cdiv class=\"instruction-container\"\u003e\n    \u003cdiv class=\"img-container\"\u003e\n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Wire\/return.jpg\" alt=\"\" style=\"width: 100%; height: auto;\"\u003e\n    \u003c\/div\u003e\n    \u003cdiv class=\"text-container\"\u003e\n        \u003cp class=\"section-description\"\u003e\n            This model uses a 2-wire auto-return wiring method. For 3-way valves, the ON and OFF positions correspond to different flow paths. When power is applied, the valve switches to the ON flow path; when power is lost or disconnected, it automatically returns to the default OFF flow path.\n        \u003c\/p\u003e\n        \u003cul class=\"section-description2\"\u003e\n            \u003cli\u003eFor the basic version without signal feedback, simply ignore the signal wire connections shown in the diagram.\u003c\/li\u003e\n            \u003cli\u003eWire Color Coding: BK (Black), RD (Red), YW (Yellow), WT (White), BU (Blue), GN (Green), and OG (Orange).\u003c\/li\u003e\n            \u003cli\u003eFor reliable auto-reset performance, power the valve for at least 60 seconds (≥60s) during first commissioning or after a prolonged power cut.\u003c\/li\u003e\n            \u003cli\u003eBefore manual operation, disconnect power and wait briefly for the actuator to discharge.\u003c\/li\u003e\n        \u003c\/ul\u003e\n    \u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- FAQ --\u003e\n\u003cdiv\u003e\n    \u003ch2 class=\"section-title\"\u003eFAQ\u003c\/h2\u003e\n    \u003cp class=\"faq\"\u003e\u003cb\u003eProblem 1: What is unique about the connection method of this ball valve?\u003c\/b\u003e\u003c\/p\u003e\n    \u003cdiv class=\"instruction-container\"\u003e\n        \u003cdiv class=\"img-container\"\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/UPVC2\/size-3.jpg\" alt=\"\" style=\"width: 100%; height: auto;\"\u003e\n        \u003c\/div\u003e\n        \u003cdiv class=\"text-container\"\u003e\n            \u003cp class=\"section-description\"\u003e\n                The larger sizes of our ball valve series (1-1\/4\", 1-1\/2\", and 2\") come standard with \u003cstrong\u003e\u003cu\u003eSocket End ports\u003c\/u\u003e\u003c\/strong\u003e for solvent cement bonding and a \u003cstrong\u003e\u003cu\u003eUnion structure\u003c\/u\u003e\u003c\/strong\u003e for easier installation and maintenance, instead of common threaded connections such as NPT or G.\u003cbr\u003e\n                This union design allows the valve body to be installed or removed more easily for maintenance or replacement, without cutting the pipe or rotating the valve body itself.\u003cbr\u003e\n                The pipe sockets are made to a \u003cstrong\u003e\u003cu\u003eUS standard\u003c\/u\u003e\u003c\/strong\u003e. Please note that the Socket Inside Diameter (I.D.) may vary by national standard even for the same nominal size, such as 1-1\/4\". For other connection standards, including British Standard, Japanese Industrial Standard, or others, please contact our customer service team.\n            \u003c\/p\u003e\n        \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cp class=\"faq\"\u003e\u003cb\u003eProblem 2: Does a 3-way valve have normally open or normally closed status?\u003c\/b\u003e\u003c\/p\u003e\n    \u003cp class=\"section-description\"\u003e\n        For 3-way valves, ON and OFF should be understood as two different flow path positions, rather than simply normally open or normally closed. Each ON\/OFF position corresponds to a specific flow path. For auto-return models, the valve returns to its default OFF flow path when power is lost.\n    \u003c\/p\u003e\n\n    \u003cp class=\"faq\"\u003e\u003cb\u003eProblem 3: How to choose the correct 3-way flow path type?\u003c\/b\u003e\u003c\/p\u003e\n    \u003cdiv class=\"instruction-container\"\u003e\n        \u003cdiv class=\"img-container\"\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/UPVC3\/flow%20path.png\" alt=\"\" style=\"width: 100%; height: auto;\"\u003e\n        \u003c\/div\u003e\n        \u003cdiv class=\"text-container\"\u003e\n            \u003cp class=\"section-description\"\u003e\n                This 3-way electric ball valve is available in three flow path configurations: \u003cstrong\u003eL-type\u003c\/strong\u003e, \u003cstrong\u003eT-type T1\u003c\/strong\u003e, and \u003cstrong\u003eT-type T2\u003c\/strong\u003e. The diagrams show the corresponding flow path for each configuration when the valve is in the ON and OFF positions.\u003cbr\u003e\n                Please note that ON and OFF each correspond to a different flow path. For wiring instructions specific to your model, please refer to the Wiring Schematics section. A connection such as C-B means the two ports are open to each other, not a fixed flow direction.\n            \u003c\/p\u003e\n        \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cp class=\"faq\"\u003e\u003cb\u003eProblem 4: What precautions apply to auto-return models?\u003c\/b\u003e\u003c\/p\u003e\n    \u003cp class=\"section-description\"\u003e\n        The auto-return ball valve requires a minimum power-on duration of 60 seconds (≥60s). This step is mandatory during first commissioning or after a prolonged power cut to ensure reliable auto-reset performance. Before using the manual override, always disconnect the power first. For auto-return models, please wait for a short period after power is disconnected before manual operation, as the actuator needs time to discharge; otherwise, the valve may be difficult to turn manually.\n    \u003c\/p\u003e\n\n    \u003cp class=\"faq\"\u003e\u003cb\u003eProblem 5: Does this model come with a manual function?\u003c\/b\u003e\u003c\/p\u003e\n    \u003cp class=\"section-description\"\u003e\n        \u003cstrong\u003eYes.\u003c\/strong\u003e The manual override function allows you to control the valve position during a power outage. A hexagonal wrench is included with the valve for this purpose.\u003cbr\u003e\n        Power must be disconnected before manual operation. Turn the valve according to the \"O\" and \"S\" indicators: \"O\" = ON, \"S\" = OFF. The valve should be turned fully to the ON or OFF position; do not leave it in a middle position, as this may damage the valve. For auto-return models, wait for a short period after disconnecting power before manual operation.\n    \u003c\/p\u003e\n\n    \u003cp class=\"faq\"\u003e\u003cb\u003eProblem 6: How to read the indicator window?\u003c\/b\u003e\u003c\/p\u003e\n    \u003cp class=\"section-description\"\u003e\n        The external arrow shows the valve position. When the arrow points to \"0\", the valve is in the OFF position; when it points to \"90\", the valve is in the ON position.\n    \u003c\/p\u003e\n\n    \u003cp class=\"faq\"\u003e\u003cb\u003eProblem 7: What is a Union connection?\u003c\/b\u003e\u003c\/p\u003e\n    \u003cp class=\"section-description\"\u003e\n        A Union connection is a detachable valve structure that allows the valve body to be removed more easily for maintenance or replacement without cutting the pipe. On this product, the pipe connection ends are Socket End ports designed for solvent cement bonding.\n    \u003c\/p\u003e\n\n    \u003cp class=\"faq\"\u003e\u003cb\u003eProblem 8: What should be noted about the four main control methods?\u003c\/b\u003e\u003c\/p\u003e\n    \u003cp class=\"section-description\"\u003e\n        Please pay attention to the wiring type when purchasing. Only auto-return models will automatically return to the default OFF flow path when power is lost. Other control methods do not automatically reset after power loss and will remain in their current flow path.\n    \u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/body\u003e","brand":"U.S. Solid","offers":[{"title":"Default Title","offer_id":47870946771199,"sku":"JFMSV00611","price":257.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/1_9cb976c0-79e1-42b2-923a-d87c53f8f0fa.jpg?v=1765849424"},{"product_id":"1-2-upvc-motorized-ball-valve-2-wire-auto-return-with-manual-function-9-36v-ac-dc-normally-closed","title":"1\/2\" UPVC Motorized Ball Valve - 2 Wire Auto Return with Manual Function, 9-36V AC\/DC, Normally Closed","description":"\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e \u003cmeta content=\"width=device-width, initial-scale=1.0\" name=\"viewport\"\u003e\u003c\/p\u003e\n\u003cstyle\u003e\n        \n        .desktop-img {\n            display: block;\n        }\n        .mobile-img {\n            display: none;\n        } \n        \n        .section-title {\n            font-size: 22px;\n            line-height: 22px;\n            font-weight: bold;\n            margin: 15px 0 5px; \n            font-family: Arial;\n        }\n        \n        .section-title2 {\n            font-size: 22px;\n            line-height: 22px;\n            font-weight: bold;\n            margin: 15px 0 3px; \n            font-family: Arial;\n        }\n       \n        .section-title3 {\n            font-size: 22px;\n            line-height: 22px;\n            font-weight: bold;\n            margin: 15px 0 10px; \n            font-family: Arial;\n        }\n\n        \n        .section-description {\n            font-size: 16px;\n            line-height: 26px;\n            margin-top: 0px;\n            margin-bottom: 5px; \n            font-family: Arial;\n        }\n      \n        .faq {\n            font-size: 16px; \n            margin: 0; \n            line-height: 26px; \n            background-color: #f2f2f2; \n            padding: 5px;\n        }\n        \n        .section-description2 {\n            font-size: 16px;\n            line-height: 26px;\n            margin: 0px; \n            font-family: Arial;\n        }\n        \n.parameters-table-wrapper {\n    overflow-x: auto; \n    -webkit-overflow-scrolling: touch; \n    margin-top: 0px;\n}\n\n\n.parameters-table {\n    width: 100%;\n    min-width: 1000px;\n    border-collapse: collapse;\n    margin-top: 0px;\n}\n\n.parameters-table th, .parameters-table td {\n    border-top: 1.2px solid #a6a6a6; \n    border-bottom: 1.2px solid #a6a6a6;  \n    border-left: none;  \n    border-right: none;  \n    padding: 5px 2px;\n    text-align: left;\n    font-size: 16px;\n    line-height: 16px;\n}\n\n.parameters-table th {\n    background-color: #f2f2f2;\n    color: #2c2c2c;\n    font-weight: bold;\n}\n\n\n.parameters-table .bg-gray {\n    background-color: #f2f2f2;  \n}\n\n\n.options-table-wrapper {\n    overflow-x: auto; \n    -webkit-overflow-scrolling: touch; \n    margin-top: 0px;\n}\n\n.options-table {\n    width: 100%;\n    min-width: 1000px; \n    border-collapse: collapse;\n    margin-top: 0px;\n    box-shadow: 0 6px 25px rgba(0, 0, 0, 0.1); \n}\n\n.options-table th, .options-table td {\n    border: 2px solid #000;  \n    padding: 5px 2px;  \n    text-align: center;\n    font-size: 16px;\n    line-height: 16px;\n}\n\n.options-table th {\n    background-color: #f2f2f2;\n    color: #2c2c2c;\n    font-weight: bold;\n}\n\n\n.parameters-table2 {\n    width: 100%;\n    min-width: 1000px; \n    border-collapse: collapse;\n    margin-top: 0px;\n}\n\n.parameters-table2 th, .parameters-table2 td {\n    border-top: 1.2px solid #a6a6a6;  \n    border-bottom: 1.2px solid #a6a6a6; \n    border-left: none;  \n    border-right: none; \n    padding: 5px 2px;\n    text-align: center;\n    font-size: 16px;\n    line-height: 16px;\n}\n\n.parameters-table2 th {\n    background-color: #f2f2f2;\n    color: #2c2c2c;\n    font-weight: bold;\n}\n\n\n.parameters-table2 .bg-gray {\n    background-color: #f2f2f2;  \n}\n\n\n.options-table-wrapper2 {\n    overflow-x: auto; \n    -webkit-overflow-scrolling: touch; \n    margin-top: 0px;\n}\n\n        .instruction-container {\n             display: flex;\n             justify-content: space-between;\n             align-items: flex-start;\n             gap: 10px; \/* Adds space between the video and the text *\/\n             margin-bottom: 0px; \/* Adds some space below the section *\/\n        }\n\n      \n        .img-container {\n              width: 50%; \n             display: flex;\n             justify-content: center; \n        }\n\n      \n        .text-container {\n               width: 50%; \n             font-size: 16px;\n             font-family: Arial;\n             \n         }\n\n         .instruction-container2 {\n             display: flex;\n             justify-content: space-between;\n             align-items: flex-start;\n             gap: 10px; \/* Adds space between the video and the text *\/\n             margin-bottom: 0px; \/* Adds some space below the section *\/\n        }\n\n      \n        .img-container2 {\n             width: 50%; \n             display: flex;\n             justify-content: center; \n        }\n\n      \n        .text-container2 {\n             width: 50%; \n            display: flex;\n             justify-content: center;\n         }\n\n\n@media (max-width: 768px) {\n    .parameters-table th, .parameters-table td {\n        font-size: 14px; \n        padding: 8px 4px; \n    }\n\n   \n    .options-table th, .options-table td {\n        font-size: 14px; \n        padding: 8px 4px;\n    }\n\n    .parameters-table-wrapper {\n        overflow-x: auto;\n    }\n    .parameters-table2 th, .parameters-table2 td {\n        font-size: 14px; \n        padding: 8px 4px; \n    }\n    .parameters-table-wrapper2 {\n        overflow-x: auto;\n    }\n    .desktop-img {\n                display: none;\n            }\n            .mobile-img {\n                display: block; \n            }\n    .instruction-container {\n                flex-direction: column; \n                align-items: center;\n            }\n\n            .img-container, .text-container {\n                width: 100%; \/* Both take full width *\/\n                margin-bottom: 0px; \n            }\n            .instruction-container2 {\n                flex-direction: column; \n                align-items: center;\n            }\n\n            .img-container2, .text-container2 {\n                width: 100%; \/* Both take full width *\/\n                margin-bottom: 0px; \n            }\n    \n}\n\n@media (max-width: 480px) {\n    .parameters-table th, .parameters-table td {\n        font-size: 12px; \n        padding: 6px 3px; \n    }\n\n    \n    .options-table th, .options-table td {\n        font-size: 12px; \n    }\n\n    .parameters-table-wrapper {\n        overflow-x: auto;\n    }\n    .parameters-table2 th, .parameters-table2 td {\n        font-size: 12px; \n        padding: 6px 3px; \n    }\n    .parameters-table-wrapper2 {\n        overflow-x: auto;\n    }\n    .desktop-img {\n                display: none; \n            }\n            .mobile-img {\n                display: block; \n            }\n    .instruction-container {\n                flex-direction: column; \n            }\n            .instruction-container2 {\n                flex-direction: column; \n            }\n    \n}\n    \u003c\/style\u003e\n\u003c!-- background --\u003e\n\u003cp\u003e\u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/MSV121.jpg\"\u003e \u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/121.jpg\"\u003e\u003c\/p\u003e\n\u003c!-- Introduction --\u003e\n\u003cdiv\u003e\n\u003ch2 class=\"section-title\"\u003eIntroduction\u003c\/h2\u003e\n\u003cp class=\"section-description\"\u003eThis series of UPVC electric ball valves is an upgraded version with manual function based on the conventional UPVC electric ball valves. It combines the convenience of electric control with the safety of manual control, and is suitable for various working conditions. \u003cbr\u003eThe valve adopts a two-wire automatic reset design. The manual function allows users to manually open or close the valve in case of sudden power failure or no power supply, which effectively avoids working condition stagnation caused by power failure and ensures the continuity and flexibility of use. The whole valve is made of UPVC material, which is lighter, more economical and practical compared with brass or stainless steel materials.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- Applications--\u003e\n\u003ch2 class=\"section-title2\"\u003eApplications\u003c\/h2\u003e\n\u003cp\u003e\u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/JFMSV461-a.jpg\"\u003e \u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/JFMSV461-a-p.jpg\"\u003e\u003c\/p\u003e\n\u003c!-- Features --\u003e\n\u003cdiv\u003e\n\u003ch2 class=\"section-title\"\u003eFeatures\u003c\/h2\u003e\n\u003cul class=\"section-description2\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eNormally Closed:\u003c\/strong\u003eClosed when unpowered, opens when energized.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNPT \/ G Threading:\u003c\/strong\u003e NPT (National Pipe Taper) and G (BSPP) to accommodate diverse global specifications, ensuring a secure seal with \u003ca href=\"https:\/\/ussolid.com\/products\/u-s-solid-10-rolls-0-7-inch-w-x-905-inches-l-teflon-tape-plumbers-tape-yellow-shell-html?_pos=3\u0026amp;_sid=7aa2e2725\u0026amp;_ss=r\" target=\"_blank\"\u003eteflon tape\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eValve Body Material:\u003c\/strong\u003e Constructed from UPVC, offering strong corrosion resistance, lower cost, lightweight and easy installation, with lower temperature and pressure resistance than brass and stainless steel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e9V-36V AC\/DC:\u003c\/strong\u003e Works effectively over entire voltage range, this motorized ball valve will open or close valve in 6~8 seconds.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e2 Wire Auto Return:\u003c\/strong\u003e Simple two-wire connection, automatically returning to its safe state when power is removed.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManual Function:\u003c\/strong\u003e Enables emergency actuation via a dedicated hand knob, ensuring the valve can be quickly opened or closed without electrical power.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/JFMSV121-1.jpg\"\u003e \u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/JFMSV121-1-p-1.jpg\"\u003e \u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/JFMSV121-1-p-2.jpg\"\u003e\u003c\/p\u003e\n\u003c!-- User Manual --\u003e\n\u003ch2 class=\"section-title\"\u003eUser Manual\u003c\/h2\u003e\n\u003cp class=\"section-description\"\u003eTo learn how to use this product, please refer to the \u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/Manual-U.S.%20Solid%20USS-MSV%20Motorized%20Ball%20Valves%20with%20Manual%20Function.pdf\" target=\"_blank\"\u003euser manual. \u003c\/a\u003e\u003c\/p\u003e\n\u003c!-- Technical Data --\u003e\n\u003ch2 class=\"section-title3\"\u003eTechnical Data\u003c\/h2\u003e\n\u003cdiv class=\"parameters-table-wrapper\"\u003e\n\u003ctable class=\"parameters-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eUSS-MSV00121\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003ePort Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1\/2\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eThread Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eNPT\/G\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eBody Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eUPVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eMax Torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2 Nm\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eWiring Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2 Wire Auto Return\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eOperation Mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eNormally Closed\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eFlow Aperture\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e15 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eBore Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eFull Port\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eGasket\/Diaphragm\/Seal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003ePTFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eOperating Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e6-8s\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eAC\/DC 9-36V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eIP Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIP65\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eMax Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e5W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eMedium Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e32℉-131℉(0℃-55℃)\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eLife Expectancy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e50,000 to 80,000 Cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eMax Medium Pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e145 PSI (1.0 Mpa)\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eSuitable Media\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eWater, air, oil and gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eGross Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.6 lbs\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003ePacking Dimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e3.2\"x3.7\"x5.2\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp class=\"section-description\"\u003e*To view the full table on mobile, please swipe left or right on the screen.\u003c\/p\u003e\n\n\u003ch2 class=\"section-title3\"\u003eCE Certified Quality \u0026amp; Safety\u003c\/h2\u003e\n\u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/CE\/CE-EMC.jpg\"\u003e\n\u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/CE\/CE-EMC.jpg\"\u003e\n\u003ch2 class=\"section-title\"\u003eWIRING\u003c\/h2\u003e\n\u003cdiv class=\"instruction-container2\"\u003e\n\u003cdiv class=\"img-container2\"\u003e\u003cimg alt=\"\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" style=\"width: 100%; height: auto;\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"text-container\"\u003e\u003cimg alt=\"\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" style=\"width: 100%; height: auto;\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp class=\"section-description\"\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e The product shown in the demonstration GIF may not match the actual product in this listing (e.g., differences in normally open (NO) or normally closed (NC) types). This is normal, and the GIF is intended to demonstrate the wiring method for a 2-wire auto return motorized ball valve.\u003c\/p\u003e\n\u003c!-- Manual Function --\u003e\n\u003ch2 class=\"section-title\"\u003eManual Function\u003c\/h2\u003e\n\u003cp class=\"section-description\"\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e For the 2-wire auto-reset model, wait briefly before manual operation to allow the capacitor to discharge fully before turning the handwheel.\u003c\/p\u003e\n\u003cdiv class=\"instruction-container\"\u003e\n\u003cdiv class=\"img-container\"\u003e\u003cimg alt=\"\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/jfmsv121-manual-function.jpg\" style=\"width: 100%; height: auto;\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"text-container\"\u003e\n\u003cp class=\"section-title\"\u003eRed arrow\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003eThe valves is fully closed when the red arrow on the position indicator ② points to \"0\"(vertical to the pipe).Likewise,the valve is fully open when it points to \"90\"(parallel to the pipe).\u003c\/p\u003e\n\u003cp class=\"section-title\"\u003eSteps\u003c\/p\u003e\n\u003cul class=\"section-description2\"\u003e\n\u003cli\u003eBefore manual operation, ensure the valve is in a power-off state.\u003c\/li\u003e\n\u003cli\u003eFirst, gently pull up the handwheel. At this point, rotating it will open or close the passage. You will feel a slight lift of the rod when pulling up; if it cannot be lifted, try rotating it to adjust the position.\u003c\/li\u003e\n\u003cli\u003eDo not use excessive force. While rotating, pay attention to the red line in the indicator window to avoid over-operation.\u003c\/li\u003e\n\u003cli\u003eAfter completing the manual operation, press down the handwheel to ensure the normal operation of the electric function.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- FAQ --\u003e\n\u003ch2 class=\"section-title\"\u003eFAQ\u003c\/h2\u003e\n\u003cp class=\"faq\"\u003e\u003cb\u003eProblem 1: What is the difference between N.C. (Normally Closed) and N.O. (Normally Open)?\u003c\/b\u003e\u003c\/p\u003e\n\u003cul class=\"section-description2\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eNormally Closed (NC):\u003c\/strong\u003e Valve remains closed when power is off, opening only when energized. Ideal for fail-safe closed applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNormally Open (NO):\u003c\/strong\u003e Valve remains open when power is off, closing only when energized. Ideal for fail-safe open applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"faq\"\u003e\u003cb\u003eProblem 2: What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n\u003cul class=\"section-description2\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eFull Port:\u003c\/strong\u003e Matches pipe diameter, minimal flow restriction, ideal for high flow and low pressure drop.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard Port:\u003c\/strong\u003e Smaller than pipe diameter, higher resistance, suitable for general flow and pressure needs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"faq\"\u003e\u003cb\u003eProblem 3: Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\u003cstrong\u003eNO.\u003c\/strong\u003e This valve is industrial-grade and not recommended for potable water applications.\u003c\/p\u003e\n\u003cp class=\"faq\"\u003e\u003cb\u003eProblem 4: For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n\u003cp class=\"faq\"\u003e\u003cb\u003eProblem 5: Why can't the handwheel be turned when using the manual function?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003eFor valves with automatic reset, if the handwheel cannot be turned despite following the correct procedure, it is usually because the capacitor in the valve has not fully discharged. Wait for several dozen seconds until the capacitor is discharged, then the manual function can be used normally.\u003c\/p\u003e\n\u003c!-- background --\u003e\n\u003cp\u003e\u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHSV\/jfhsv\/jfhsv-ptfe-viton.png\"\u003e \u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHSV\/jfhsv\/jfhsv-ptfe-viton-p.png\"\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e*\u003cstrong\u003eImportant:\u003c\/strong\u003e Check marks (√) denote conditional suitability only; crosses (×) indicate complete incompatibility.\u003c\/p\u003e","brand":"U.S. Solid","offers":[{"title":"NPT","offer_id":47872136741119,"sku":"JFMSV00121","price":41.49,"currency_code":"USD","in_stock":true},{"title":"G","offer_id":47872136773887,"sku":"JFMSV00121-G","price":37.39,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/4_c0ba9c37-f897-44e6-adf0-2f09a85fed26.png?v=1770198046"},{"product_id":"3-4-upvc-motorized-ball-valve-2-wire-auto-return-with-manual-function-9-36v-ac-dc-normally-closed","title":"3\/4\" UPVC Motorized Ball Valve - 2 Wire Auto Return with Manual Function, 9-36V AC\/DC, Normally Closed","description":"\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e \u003cmeta content=\"width=device-width, initial-scale=1.0\" name=\"viewport\"\u003e\u003c\/p\u003e\n\u003cstyle\u003e\n        \n        .desktop-img {\n            display: block;\n        }\n        .mobile-img {\n            display: none;\n        } \n        \n        .section-title {\n            font-size: 22px;\n            line-height: 22px;\n            font-weight: bold;\n            margin: 15px 0 5px; \n            font-family: Arial;\n        }\n        \n        .section-title2 {\n            font-size: 22px;\n            line-height: 22px;\n            font-weight: bold;\n            margin: 15px 0 3px; \n            font-family: Arial;\n        }\n       \n        .section-title3 {\n            font-size: 22px;\n            line-height: 22px;\n            font-weight: bold;\n            margin: 15px 0 10px; \n            font-family: Arial;\n        }\n\n        \n        .section-description {\n            font-size: 16px;\n            line-height: 26px;\n            margin-top: 0px;\n            margin-bottom: 5px; \n            font-family: Arial;\n        }\n      \n        .faq {\n            font-size: 16px; \n            margin: 0; \n            line-height: 26px; \n            background-color: #f2f2f2; \n            padding: 5px;\n        }\n        \n        .section-description2 {\n            font-size: 16px;\n            line-height: 26px;\n            margin: 0px; \n            font-family: Arial;\n        }\n        \n.parameters-table-wrapper {\n    overflow-x: auto; \n    -webkit-overflow-scrolling: touch; \n    margin-top: 0px;\n}\n\n\n.parameters-table {\n    width: 100%;\n    min-width: 1000px;\n    border-collapse: collapse;\n    margin-top: 0px;\n}\n\n.parameters-table th, .parameters-table td {\n    border-top: 1.2px solid #a6a6a6; \n    border-bottom: 1.2px solid #a6a6a6;  \n    border-left: none;  \n    border-right: none;  \n    padding: 5px 2px;\n    text-align: left;\n    font-size: 16px;\n    line-height: 16px;\n}\n\n.parameters-table th {\n    background-color: #f2f2f2;\n    color: #2c2c2c;\n    font-weight: bold;\n}\n\n\n.parameters-table .bg-gray {\n    background-color: #f2f2f2;  \n}\n\n\n.options-table-wrapper {\n    overflow-x: auto; \n    -webkit-overflow-scrolling: touch; \n    margin-top: 0px;\n}\n\n.options-table {\n    width: 100%;\n    min-width: 1000px; \n    border-collapse: collapse;\n    margin-top: 0px;\n    box-shadow: 0 6px 25px rgba(0, 0, 0, 0.1); \n}\n\n.options-table th, .options-table td {\n    border: 2px solid #000;  \n    padding: 5px 2px;  \n    text-align: center;\n    font-size: 16px;\n    line-height: 16px;\n}\n\n.options-table th {\n    background-color: #f2f2f2;\n    color: #2c2c2c;\n    font-weight: bold;\n}\n\n\n.parameters-table2 {\n    width: 100%;\n    min-width: 1000px; \n    border-collapse: collapse;\n    margin-top: 0px;\n}\n\n.parameters-table2 th, .parameters-table2 td {\n    border-top: 1.2px solid #a6a6a6;  \n    border-bottom: 1.2px solid #a6a6a6; \n    border-left: none;  \n    border-right: none; \n    padding: 5px 2px;\n    text-align: center;\n    font-size: 16px;\n    line-height: 16px;\n}\n\n.parameters-table2 th {\n    background-color: #f2f2f2;\n    color: #2c2c2c;\n    font-weight: bold;\n}\n\n\n.parameters-table2 .bg-gray {\n    background-color: #f2f2f2;  \n}\n\n\n.options-table-wrapper2 {\n    overflow-x: auto; \n    -webkit-overflow-scrolling: touch; \n    margin-top: 0px;\n}\n\n        .instruction-container {\n             display: flex;\n             justify-content: space-between;\n             align-items: flex-start;\n             gap: 10px; \/* Adds space between the video and the text *\/\n             margin-bottom: 0px; \/* Adds some space below the section *\/\n        }\n\n      \n        .img-container {\n              width: 50%; \n             display: flex;\n             justify-content: center; \n        }\n\n      \n        .text-container {\n               width: 50%; \n             font-size: 16px;\n             font-family: Arial;\n             \n         }\n\n         .instruction-container2 {\n             display: flex;\n             justify-content: space-between;\n             align-items: flex-start;\n             gap: 10px; \/* Adds space between the video and the text *\/\n             margin-bottom: 0px; \/* Adds some space below the section *\/\n        }\n\n      \n        .img-container2 {\n             width: 50%; \n             display: flex;\n             justify-content: center; \n        }\n\n      \n        .text-container2 {\n             width: 50%; \n            display: flex;\n             justify-content: center;\n         }\n\n\n@media (max-width: 768px) {\n    .parameters-table th, .parameters-table td {\n        font-size: 14px; \n        padding: 8px 4px; \n    }\n\n   \n    .options-table th, .options-table td {\n        font-size: 14px; \n        padding: 8px 4px;\n    }\n\n    .parameters-table-wrapper {\n        overflow-x: auto;\n    }\n    .parameters-table2 th, .parameters-table2 td {\n        font-size: 14px; \n        padding: 8px 4px; \n    }\n    .parameters-table-wrapper2 {\n        overflow-x: auto;\n    }\n    .desktop-img {\n                display: none;\n            }\n            .mobile-img {\n                display: block; \n            }\n    .instruction-container {\n                flex-direction: column; \n                align-items: center;\n            }\n\n            .img-container, .text-container {\n                width: 100%; \/* Both take full width *\/\n                margin-bottom: 0px; \n            }\n            .instruction-container2 {\n                flex-direction: column; \n                align-items: center;\n            }\n\n            .img-container2, .text-container2 {\n                width: 100%; \/* Both take full width *\/\n                margin-bottom: 0px; \n            }\n    \n}\n\n@media (max-width: 480px) {\n    .parameters-table th, .parameters-table td {\n        font-size: 12px; \n        padding: 6px 3px; \n    }\n\n    \n    .options-table th, .options-table td {\n        font-size: 12px; \n    }\n\n    .parameters-table-wrapper {\n        overflow-x: auto;\n    }\n    .parameters-table2 th, .parameters-table2 td {\n        font-size: 12px; \n        padding: 6px 3px; \n    }\n    .parameters-table-wrapper2 {\n        overflow-x: auto;\n    }\n    .desktop-img {\n                display: none; \n            }\n            .mobile-img {\n                display: block; \n            }\n    .instruction-container {\n                flex-direction: column; \n            }\n            .instruction-container2 {\n                flex-direction: column; \n            }\n    \n}\n    \u003c\/style\u003e\n\u003c!-- background --\u003e\n\u003cp\u003e\u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/MSV121.jpg\"\u003e \u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/121.jpg\"\u003e\u003c\/p\u003e\n\u003c!-- Introduction --\u003e\n\u003cdiv\u003e\n\u003ch2 class=\"section-title\"\u003eIntroduction\u003c\/h2\u003e\n\u003cp class=\"section-description\"\u003eThis series of UPVC electric ball valves is an upgraded version with manual function based on the conventional UPVC electric ball valves. It combines the convenience of electric control with the safety of manual control, and is suitable for various working conditions. \u003cbr\u003eThe valve adopts a two-wire automatic reset design. The manual function allows users to manually open or close the valve in case of sudden power failure or no power supply, which effectively avoids working condition stagnation caused by power failure and ensures the continuity and flexibility of use. The whole valve is made of UPVC material, which is lighter, more economical and practical compared with brass or stainless steel materials.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- Applications--\u003e\n\u003ch2 class=\"section-title2\"\u003eApplications\u003c\/h2\u003e\n\u003cp\u003e\u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/JFMSV461-a.jpg\"\u003e \u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/JFMSV461-a-p.jpg\"\u003e\u003c\/p\u003e\n\u003c!-- Features --\u003e\n\u003cdiv\u003e\n\u003ch2 class=\"section-title\"\u003eFeatures\u003c\/h2\u003e\n\u003cul class=\"section-description2\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eNormally Closed:\u003c\/strong\u003eClosed when unpowered, opens when energized.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNPT \/ G Threading:\u003c\/strong\u003e NPT (National Pipe Taper) and G (BSPP) to accommodate diverse global specifications, ensuring a secure seal with \u003ca href=\"https:\/\/ussolid.com\/products\/u-s-solid-10-rolls-0-7-inch-w-x-905-inches-l-teflon-tape-plumbers-tape-yellow-shell-html?_pos=3\u0026amp;_sid=7aa2e2725\u0026amp;_ss=r\" target=\"_blank\"\u003eteflon tape\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eValve Body Material:\u003c\/strong\u003e Constructed from UPVC, offering strong corrosion resistance, lower cost, lightweight and easy installation, with lower temperature and pressure resistance than brass and stainless steel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e9V-36V AC\/DC:\u003c\/strong\u003e Works effectively over entire voltage range, this motorized ball valve will open or close valve in 6~8 seconds.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e2 Wire Auto Return:\u003c\/strong\u003e Simple two-wire connection, automatically returning to its safe state when power is removed.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManual Function:\u003c\/strong\u003e Enables emergency actuation via a dedicated hand knob, ensuring the valve can be quickly opened or closed without electrical power.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/JFMSV121-1.jpg\"\u003e \u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/JFMSV121-1-p-1.jpg\"\u003e \u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/JFMSV121-1-p-2.jpg\"\u003e\u003c\/p\u003e\n\u003c!-- User Manual --\u003e\n\u003ch2 class=\"section-title\"\u003eUser Manual\u003c\/h2\u003e\n\u003cp class=\"section-description\"\u003eTo learn how to use this product, please refer to the \u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/Manual-U.S.%20Solid%20USS-MSV%20Motorized%20Ball%20Valves%20with%20Manual%20Function.pdf\" target=\"_blank\"\u003euser manual. \u003c\/a\u003e\u003c\/p\u003e\n\u003c!-- Technical Data --\u003e\n\u003ch2 class=\"section-title3\"\u003eTechnical Data\u003c\/h2\u003e\n\u003cdiv class=\"parameters-table-wrapper\"\u003e\n\u003ctable class=\"parameters-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eUSS-MSV00122\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003ePort Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e3\/4\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eThread Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eNPT\/G\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eBody Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eUPVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eMax Torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2 Nm\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eWiring Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2 Wire Auto Return\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eOperation Mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eNormally Closed\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eFlow Aperture\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e20 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eBore Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eFull Port\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eGasket\/Diaphragm\/Seal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003ePTFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eOperating Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e6-8s\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eAC\/DC 9-36V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eIP Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIP65\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eMax Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e5W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eMedium Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e32℉-131℉(0℃-55℃)\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eLife Expectancy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e50,000 to 80,000 Cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eMax Medium Pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e145 PSI (1.0 Mpa)\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eSuitable Media\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eWater, air, oil and gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eGross Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.68 lbs\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003ePacking Dimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e3.46\"x3.70\"x5.12\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp class=\"section-description\"\u003e*To view the full table on mobile, please swipe left or right on the screen.\u003c\/p\u003e\n\n\u003ch2 class=\"section-title3\"\u003eCE Certified Quality \u0026amp; Safety\u003c\/h2\u003e\n\u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/CE\/CE-EMC.jpg\"\u003e\n\u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/CE\/CE-EMC.jpg\"\u003e\n\u003ch2 class=\"section-title\"\u003eWIRING\u003c\/h2\u003e\n\u003cdiv class=\"instruction-container2\"\u003e\n\u003cdiv class=\"img-container2\"\u003e\u003cimg alt=\"\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" style=\"width: 100%; height: auto;\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"text-container\"\u003e\u003cimg alt=\"\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" style=\"width: 100%; height: auto;\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp class=\"section-description\"\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e The product shown in the demonstration GIF may not match the actual product in this listing (e.g., differences in normally open (NO) or normally closed (NC) types). This is normal, and the GIF is intended to demonstrate the wiring method for a 2-wire auto return motorized ball valve.\u003c\/p\u003e\n\u003c!-- Manual Function --\u003e\n\u003ch2 class=\"section-title\"\u003eManual Function\u003c\/h2\u003e\n\u003cp class=\"section-description\"\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e For the 2-wire auto-reset model, wait briefly before manual operation to allow the capacitor to discharge fully before turning the handwheel.\u003c\/p\u003e\n\u003cdiv class=\"instruction-container\"\u003e\n\u003cdiv class=\"img-container\"\u003e\u003cimg alt=\"\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/jfmsv121-manual-function.jpg\" style=\"width: 100%; height: auto;\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"text-container\"\u003e\n\u003cp class=\"section-title\"\u003eRed arrow\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003eThe valves is fully closed when the red arrow on the position indicator ② points to \"0\"(vertical to the pipe).Likewise,the valve is fully open when it points to \"90\"(parallel to the pipe).\u003c\/p\u003e\n\u003cp class=\"section-title\"\u003eSteps\u003c\/p\u003e\n\u003cul class=\"section-description2\"\u003e\n\u003cli\u003eBefore manual operation, ensure the valve is in a power-off state.\u003c\/li\u003e\n\u003cli\u003eFirst, gently pull up the handwheel. At this point, rotating it will open or close the passage. You will feel a slight lift of the rod when pulling up; if it cannot be lifted, try rotating it to adjust the position.\u003c\/li\u003e\n\u003cli\u003eDo not use excessive force. While rotating, pay attention to the red line in the indicator window to avoid over-operation.\u003c\/li\u003e\n\u003cli\u003eAfter completing the manual operation, press down the handwheel to ensure the normal operation of the electric function.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- FAQ --\u003e\n\u003ch2 class=\"section-title\"\u003eFAQ\u003c\/h2\u003e\n\u003cp class=\"faq\"\u003e\u003cb\u003eProblem 1: What is the difference between N.C. (Normally Closed) and N.O. (Normally Open)?\u003c\/b\u003e\u003c\/p\u003e\n\u003cul class=\"section-description2\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eNormally Closed (NC):\u003c\/strong\u003e Valve remains closed when power is off, opening only when energized. Ideal for fail-safe closed applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNormally Open (NO):\u003c\/strong\u003e Valve remains open when power is off, closing only when energized. Ideal for fail-safe open applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"faq\"\u003e\u003cb\u003eProblem 2: What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n\u003cul class=\"section-description2\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eFull Port:\u003c\/strong\u003e Matches pipe diameter, minimal flow restriction, ideal for high flow and low pressure drop.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard Port:\u003c\/strong\u003e Smaller than pipe diameter, higher resistance, suitable for general flow and pressure needs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"faq\"\u003e\u003cb\u003eProblem 3: Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\u003cstrong\u003eNO.\u003c\/strong\u003e This valve is industrial-grade and not recommended for potable water applications.\u003c\/p\u003e\n\u003cp class=\"faq\"\u003e\u003cb\u003eProblem 4: For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n\u003cp class=\"faq\"\u003e\u003cb\u003eProblem 5: Why can't the handwheel be turned when using the manual function?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003eFor valves with automatic reset, if the handwheel cannot be turned despite following the correct procedure, it is usually because the capacitor in the valve has not fully discharged. Wait for several dozen seconds until the capacitor is discharged, then the manual function can be used normally.\u003c\/p\u003e\n\u003c!-- background --\u003e\n\u003cp\u003e\u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHSV\/jfhsv\/jfhsv-ptfe-viton.png\"\u003e \u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHSV\/jfhsv\/jfhsv-ptfe-viton-p.png\"\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e*\u003cstrong\u003eImportant:\u003c\/strong\u003e Check marks (√) denote conditional suitability only; crosses (×) indicate complete incompatibility.\u003c\/p\u003e","brand":"U.S. Solid","offers":[{"title":"NPT","offer_id":47872542048511,"sku":"JFMSV00122","price":43.49,"currency_code":"USD","in_stock":true},{"title":"G","offer_id":47872542081279,"sku":"JFMSV00122-G","price":39.39,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/4_5bd530d7-b49e-40a9-8ac7-efce0bc02b96.png?v=1770198626"},{"product_id":"1-upvc-motorized-ball-valve-2-wire-auto-return-with-manual-function-9-36v-ac-dc-normally-closed","title":"1\" UPVC Motorized Ball Valve - 2 Wire Auto Return with Manual Function, 9-36V AC\/DC, Normally Closed","description":"\u003cbody\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003cmeta content=\"width=device-width, initial-scale=1.0\" name=\"viewport\"\u003e\n\u003ctitle\u003eResponsive Page with Multiple Modules\u003c\/title\u003e\n\u003cstyle\u003e\n        \n        .desktop-img {\n            display: block;\n        }\n        .mobile-img {\n            display: none;\n        } \n        \n        .section-title {\n            font-size: 22px;\n            line-height: 22px;\n            font-weight: bold;\n            margin: 15px 0 5px; \n            font-family: Arial;\n        }\n        \n        .section-title2 {\n            font-size: 22px;\n            line-height: 22px;\n            font-weight: bold;\n            margin: 15px 0 3px; \n            font-family: Arial;\n        }\n       \n        .section-title3 {\n            font-size: 22px;\n            line-height: 22px;\n            font-weight: bold;\n            margin: 15px 0 10px; \n            font-family: Arial;\n        }\n\n        \n        .section-description {\n            font-size: 16px;\n            line-height: 26px;\n            margin-top: 0px;\n            margin-bottom: 5px; \n            font-family: Arial;\n        }\n      \n        .faq {\n            font-size: 16px; \n            margin: 0; \n            line-height: 26px; \n            background-color: #f2f2f2; \n            padding: 5px;\n        }\n        \n        .section-description2 {\n            font-size: 16px;\n            line-height: 26px;\n            margin: 0px; \n            font-family: Arial;\n        }\n        \n.parameters-table-wrapper {\n    overflow-x: auto; \n    -webkit-overflow-scrolling: touch; \n    margin-top: 0px;\n}\n\n\n.parameters-table {\n    width: 100%;\n    min-width: 1000px;\n    border-collapse: collapse;\n    margin-top: 0px;\n}\n\n.parameters-table th, .parameters-table td {\n    border-top: 1.2px solid #a6a6a6; \n    border-bottom: 1.2px solid #a6a6a6;  \n    border-left: none;  \n    border-right: none;  \n    padding: 5px 2px;\n    text-align: left;\n    font-size: 16px;\n    line-height: 16px;\n}\n\n.parameters-table th {\n    background-color: #f2f2f2;\n    color: #2c2c2c;\n    font-weight: bold;\n}\n\n\n.parameters-table .bg-gray {\n    background-color: #f2f2f2;  \n}\n\n\n.options-table-wrapper {\n    overflow-x: auto; \n    -webkit-overflow-scrolling: touch; \n    margin-top: 0px;\n}\n\n.options-table {\n    width: 100%;\n    min-width: 1000px; \n    border-collapse: collapse;\n    margin-top: 0px;\n    box-shadow: 0 6px 25px rgba(0, 0, 0, 0.1); \n}\n\n.options-table th, .options-table td {\n    border: 2px solid #000;  \n    padding: 5px 2px;  \n    text-align: center;\n    font-size: 16px;\n    line-height: 16px;\n}\n\n.options-table th {\n    background-color: #f2f2f2;\n    color: #2c2c2c;\n    font-weight: bold;\n}\n\n\n.parameters-table2 {\n    width: 100%;\n    min-width: 1000px; \n    border-collapse: collapse;\n    margin-top: 0px;\n}\n\n.parameters-table2 th, .parameters-table2 td {\n    border-top: 1.2px solid #a6a6a6;  \n    border-bottom: 1.2px solid #a6a6a6; \n    border-left: none;  \n    border-right: none; \n    padding: 5px 2px;\n    text-align: center;\n    font-size: 16px;\n    line-height: 16px;\n}\n\n.parameters-table2 th {\n    background-color: #f2f2f2;\n    color: #2c2c2c;\n    font-weight: bold;\n}\n\n\n.parameters-table2 .bg-gray {\n    background-color: #f2f2f2;  \n}\n\n\n.options-table-wrapper2 {\n    overflow-x: auto; \n    -webkit-overflow-scrolling: touch; \n    margin-top: 0px;\n}\n\n        .instruction-container {\n             display: flex;\n             justify-content: space-between;\n             align-items: flex-start;\n             gap: 10px; \/* Adds space between the video and the text *\/\n             margin-bottom: 0px; \/* Adds some space below the section *\/\n        }\n\n      \n        .img-container {\n              width: 50%; \n             display: flex;\n             justify-content: center; \n        }\n\n      \n        .text-container {\n               width: 50%; \n             font-size: 16px;\n             font-family: Arial;\n             \n         }\n\n         .instruction-container2 {\n             display: flex;\n             justify-content: space-between;\n             align-items: flex-start;\n             gap: 10px; \/* Adds space between the video and the text *\/\n             margin-bottom: 0px; \/* Adds some space below the section *\/\n        }\n\n      \n        .img-container2 {\n             width: 50%; \n             display: flex;\n             justify-content: center; \n        }\n\n      \n        .text-container2 {\n             width: 50%; \n            display: flex;\n             justify-content: center;\n         }\n\n\n@media (max-width: 768px) {\n    .parameters-table th, .parameters-table td {\n        font-size: 14px; \n        padding: 8px 4px; \n    }\n\n   \n    .options-table th, .options-table td {\n        font-size: 14px; \n        padding: 8px 4px;\n    }\n\n    .parameters-table-wrapper {\n        overflow-x: auto;\n    }\n    .parameters-table2 th, .parameters-table2 td {\n        font-size: 14px; \n        padding: 8px 4px; \n    }\n    .parameters-table-wrapper2 {\n        overflow-x: auto;\n    }\n    .desktop-img {\n                display: none;\n            }\n            .mobile-img {\n                display: block; \n            }\n    .instruction-container {\n                flex-direction: column; \n                align-items: center;\n            }\n\n            .img-container, .text-container {\n                width: 100%; \/* Both take full width *\/\n                margin-bottom: 0px; \n            }\n            .instruction-container2 {\n                flex-direction: column; \n                align-items: center;\n            }\n\n            .img-container2, .text-container2 {\n                width: 100%; \/* Both take full width *\/\n                margin-bottom: 0px; \n            }\n    \n}\n\n@media (max-width: 480px) {\n    .parameters-table th, .parameters-table td {\n        font-size: 12px; \n        padding: 6px 3px; \n    }\n\n    \n    .options-table th, .options-table td {\n        font-size: 12px; \n    }\n\n    .parameters-table-wrapper {\n        overflow-x: auto;\n    }\n    .parameters-table2 th, .parameters-table2 td {\n        font-size: 12px; \n        padding: 6px 3px; \n    }\n    .parameters-table-wrapper2 {\n        overflow-x: auto;\n    }\n    .desktop-img {\n                display: none; \n            }\n            .mobile-img {\n                display: block; \n            }\n    .instruction-container {\n                flex-direction: column; \n            }\n            .instruction-container2 {\n                flex-direction: column; \n            }\n    \n}\n    \u003c\/style\u003e\n\u003c!-- background --\u003e\n\u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/MSV121.jpg\"\u003e\n\u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/121.jpg\"\u003e\n\u003c!-- Introduction --\u003e\n\u003cdiv\u003e\n\u003ch2 class=\"section-title\"\u003eIntroduction\u003c\/h2\u003e\n\u003cp class=\"section-description\"\u003e\n            This series of UPVC electric ball valves is an upgraded version with manual function based on the conventional UPVC electric ball valves. It combines the convenience of electric control with the safety of manual control, and is suitable for various working conditions. \u003cbr\u003eThe valve adopts a two-wire automatic reset design. The manual function allows users to manually open or close the valve in case of sudden power failure or no power supply, which effectively avoids working condition stagnation caused by power failure and ensures the continuity and flexibility of use. The whole valve is made of UPVC material, which is lighter, more economical and practical compared with brass or stainless steel materials.\n        \u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- Applications--\u003e\n\u003ch2 class=\"section-title2\"\u003eApplications\u003c\/h2\u003e\n\u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/JFMSV461-a.jpg\"\u003e\n\u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/JFMSV461-a-p.jpg\"\u003e\n\u003c!-- Features --\u003e\n\u003cdiv\u003e\n\u003ch2 class=\"section-title\"\u003eFeatures\u003c\/h2\u003e\n\u003cul class=\"section-description2\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eNormally Closed:\u003c\/strong\u003eClosed when unpowered, opens when energized.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNPT \/ G Threading:\u003c\/strong\u003e NPT (National Pipe Taper) and G (BSPP) to accommodate diverse global specifications, ensuring a secure seal with \u003ca href=\"https:\/\/ussolid.com\/products\/u-s-solid-10-rolls-0-7-inch-w-x-905-inches-l-teflon-tape-plumbers-tape-yellow-shell-html?_pos=3\u0026amp;_sid=7aa2e2725\u0026amp;_ss=r\" target=\"_blank\"\u003eteflon tape\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eValve Body Material:\u003c\/strong\u003e Constructed from UPVC, offering strong corrosion resistance, lower cost, lightweight and easy installation, with lower temperature and pressure resistance than brass and stainless steel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e9V-36V AC\/DC:\u003c\/strong\u003e Works effectively over entire voltage range, this motorized ball valve will open or close valve in 6~8 seconds.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e2 Wire Auto Return:\u003c\/strong\u003e Simple two-wire connection, automatically returning to its safe state when power is removed.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManual Function:\u003c\/strong\u003e Enables emergency actuation via a dedicated hand knob, ensuring the valve can be quickly opened or closed without electrical power.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/JFMSV121-1.jpg\"\u003e\n\u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/JFMSV121-1-p-1.jpg\"\u003e\n\u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/JFMSV121-1-p-2.jpg\"\u003e\n\u003c!-- User Manual --\u003e\n\u003ch2 class=\"section-title\"\u003eUser Manual\u003c\/h2\u003e\n\u003cp class=\"section-description\"\u003e\n            To learn how to use this product, please refer to the \u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/Manual-U.S.%20Solid%20USS-MSV%20Motorized%20Ball%20Valves%20with%20Manual%20Function.pdf\" target=\"_blank\"\u003euser manual.\n    \u003c\/a\u003e\u003c\/p\u003e\n\u003c!-- Technical Data --\u003e\n\u003ch2 class=\"section-title3\"\u003eTechnical Data\u003c\/h2\u003e\n\u003cdiv class=\"parameters-table-wrapper\"\u003e\n\u003ctable class=\"parameters-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eUSS-MSV00123\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003ePort Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eThread Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eNPT\/G\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eBody Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eUPVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eMax Torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2 Nm\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eWiring Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2 Wire Auto Return\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eOperation Mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eNormally Closed\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eFlow Aperture\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e25 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eBore Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eFull Port\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eGasket\/Diaphragm\/Seal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003ePTFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eOperating Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e6-8s\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eAC\/DC 9-36V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eIP Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIP65\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eMax Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e5W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eMedium Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e32℉-131℉(0℃-55℃)\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eLife Expectancy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e50,000 to 80,000 Cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eMax Medium Pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e145 PSI (1.0 Mpa)\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eSuitable Media\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eWater, air, oil and gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eGross Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.75 lbs\u003c\/td\u003e\n\u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003ePacking Dimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e3.46\"x3.70\"x5.12\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp class=\"section-description\"\u003e*To view the full table on mobile, please swipe left or right on the screen.\u003c\/p\u003e\n\n\u003ch2 class=\"section-title3\"\u003eCE Certified Quality \u0026amp; Safety\u003c\/h2\u003e\n\u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/CE\/CE-EMC.jpg\"\u003e\n\u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/CE\/CE-EMC.jpg\"\u003e\n\u003ch2 class=\"section-title\"\u003eWIRING\u003c\/h2\u003e\n\u003cdiv class=\"instruction-container2\"\u003e\n\u003cdiv class=\"img-container2\"\u003e\n\u003cimg alt=\"\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" style=\"width: 100%; height: auto;\"\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"text-container\"\u003e\n\u003cimg alt=\"\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" style=\"width: 100%; height: auto;\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp class=\"section-description\"\u003e\n\u003cstrong\u003eNote:\u003c\/strong\u003e The product shown in the demonstration GIF may not match the actual product in this listing (e.g., differences in normally open (NO) or normally closed (NC) types). This is normal, and the GIF is intended to demonstrate the wiring method for a 2-wire auto return motorized ball valve.\n        \u003c\/p\u003e\n\u003c!-- Manual Function --\u003e\n\u003ch2 class=\"section-title\"\u003eManual Function\u003c\/h2\u003e\n\u003cp class=\"section-description\"\u003e\n\u003cstrong\u003eNote:\u003c\/strong\u003e For the 2-wire auto-reset model, wait briefly before manual operation to allow the capacitor to discharge fully before turning the handwheel.\n        \u003c\/p\u003e\n\u003cdiv class=\"instruction-container\"\u003e\n\u003cdiv class=\"img-container\"\u003e\n\u003cimg alt=\"\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/jfmsv121-manual-function.jpg\" style=\"width: 100%; height: auto;\"\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"text-container\"\u003e\n\u003cp class=\"section-title\"\u003eRed arrow\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003eThe valves is fully closed when the red arrow on the position indicator ② points to \"0\"(vertical to the pipe).Likewise,the valve is fully open when it points to \"90\"(parallel to the pipe).\u003c\/p\u003e\n\u003cp class=\"section-title\"\u003eSteps\u003c\/p\u003e\n\u003cul class=\"section-description2\"\u003e\n\u003cli\u003eBefore manual operation, ensure the valve is in a power-off state.\u003c\/li\u003e\n\u003cli\u003eFirst, gently pull up the handwheel. At this point, rotating it will open or close the passage. You will feel a slight lift of the rod when pulling up; if it cannot be lifted, try rotating it to adjust the position.\u003c\/li\u003e\n\u003cli\u003eDo not use excessive force. While rotating, pay attention to the red line in the indicator window to avoid over-operation.\u003c\/li\u003e\n\u003cli\u003eAfter completing the manual operation, press down the handwheel to ensure the normal operation of the electric function.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- FAQ --\u003e\n\u003ch2 class=\"section-title\"\u003eFAQ\u003c\/h2\u003e\n\u003cp class=\"faq\"\u003e\u003cb\u003eProblem 1: What is the difference between N.C. (Normally Closed) and N.O. (Normally Open)?\u003c\/b\u003e\u003c\/p\u003e\n\u003cul class=\"section-description2\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eNormally Closed (NC):\u003c\/strong\u003e Valve remains closed when power is off, opening only when energized. Ideal for fail-safe closed applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNormally Open (NO):\u003c\/strong\u003e Valve remains open when power is off, closing only when energized. Ideal for fail-safe open applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"faq\"\u003e\u003cb\u003eProblem 2: What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n\u003cul class=\"section-description2\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eFull Port:\u003c\/strong\u003e Matches pipe diameter, minimal flow restriction, ideal for high flow and low pressure drop.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard Port:\u003c\/strong\u003e Smaller than pipe diameter, higher resistance, suitable for general flow and pressure needs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"faq\"\u003e\u003cb\u003eProblem 3: Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\u003cstrong\u003eNO.\u003c\/strong\u003e This valve is industrial-grade and not recommended for potable water applications.\u003c\/p\u003e\n\u003cp class=\"faq\"\u003e\u003cb\u003eProblem 4: For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n\u003cp class=\"faq\"\u003e\u003cb\u003eProblem 5: Why can't the handwheel be turned when using the manual function?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003eFor valves with automatic reset, if the handwheel cannot be turned despite following the correct procedure, it is usually because the capacitor in the valve has not fully discharged. Wait for several dozen seconds until the capacitor is discharged, then the manual function can be used normally.\u003c\/p\u003e\n\u003c!-- background --\u003e\n\u003cimg alt=\"Desktop Image 1\" class=\"desktop-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHSV\/jfhsv\/jfhsv-ptfe-viton.png\"\u003e\n\u003cimg alt=\"Desktop Image 2\" class=\"mobile-img\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFHSV\/jfhsv\/jfhsv-ptfe-viton-p.png\"\u003e\n\u003cp class=\"section-description\"\u003e*\u003cstrong\u003eImportant:\u003c\/strong\u003e Check marks (√) denote conditional suitability only; crosses (×) indicate complete incompatibility.\u003c\/p\u003e\n\u003c\/body\u003e","brand":"U.S. Solid","offers":[{"title":"NPT","offer_id":47872627802367,"sku":"JFMSV00123","price":47.49,"currency_code":"USD","in_stock":true},{"title":"G","offer_id":47872627835135,"sku":"JFMSV00123-G","price":43.49,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/4_bebbcdec-78e7-4dd2-89c9-367920250438.png?v=1770198792"},{"product_id":"1-1-4-double-union-upvc-motorized-ball-valve-dc-24v-3-wire-single-control-normally-closed-with-manual-override-epdm-seal","title":"1-1\/4\" Double Union UPVC Motorized Ball Valve - DC 24V, 3-Wire Single-Control, with Manual Override \u0026 EPDM Seal","description":"\u003cbody\u003e\n    \u003cmeta charset=\"UTF-8\"\u003e\n    \u003cmeta name=\"viewport\" content=\"width=device-width, initial-scale=1.0\"\u003e\n    \u003ctitle\u003eResponsive Page with Multiple Modules\u003c\/title\u003e\n    \u003cstyle\u003e\n\n        .desktop-img {\n            display: block;\n        }\n        .mobile-img {\n            display: none;\n        }\n\n        .section-title {\n            font-size: 22px;\n            line-height: 22px;\n            font-weight: bold;\n            margin: 15px 0 5px;\n            font-family: Arial;\n        }\n\n        .section-title2 {\n            font-size: 22px;\n            line-height: 22px;\n            font-weight: bold;\n            margin: 15px 0 3px;\n            font-family: Arial;\n        }\n\n        .section-title3 {\n            font-size: 22px;\n            line-height: 22px;\n            font-weight: bold;\n            margin: 15px 0 10px;\n            font-family: Arial;\n        }\n\n        .section-description {\n            font-size: 16px;\n            line-height: 26px;\n            margin-top: 0px;\n            margin-bottom: 5px;\n            font-family: Arial;\n        }\n\n        .faq {\n            font-size: 16px;\n            margin: 0;\n            line-height: 26px;\n            background-color: #f2f2f2;\n            padding: 5px;\n        }\n\n        .section-description2 {\n            font-size: 16px;\n            line-height: 26px;\n            margin: 0px;\n            font-family: Arial;\n        }\n\n        .parameters-table-wrapper {\n            overflow-x: auto;\n            -webkit-overflow-scrolling: touch;\n            margin-top: 0px;\n        }\n\n        .parameters-table {\n            width: 100%;\n            min-width: 1000px;\n            border-collapse: collapse;\n            margin-top: 0px;\n        }\n\n        .parameters-table th, .parameters-table td {\n            border-top: 1.2px solid #a6a6a6;\n            border-bottom: 1.2px solid #a6a6a6;\n            border-left: none;\n            border-right: none;\n            padding: 5px 2px;\n            text-align: left;\n            font-size: 16px;\n            line-height: 16px;\n        }\n\n        .parameters-table th {\n            background-color: #f2f2f2;\n            color: #2c2c2c;\n            font-weight: bold;\n        }\n\n        .parameters-table .bg-gray {\n            background-color: #f2f2f2;\n        }\n\n        .options-table-wrapper {\n            overflow-x: auto;\n            -webkit-overflow-scrolling: touch;\n            margin-top: 0px;\n        }\n\n        .options-table {\n            width: 100%;\n            min-width: 1000px;\n            border-collapse: collapse;\n            margin-top: 0px;\n            box-shadow: 0 6px 25px rgba(0, 0, 0, 0.1);\n        }\n\n        .options-table th, .options-table td {\n            border: 2px solid #000;\n            padding: 5px 2px;\n            text-align: center;\n            font-size: 16px;\n            line-height: 16px;\n        }\n\n        .options-table th {\n            background-color: #f2f2f2;\n            color: #2c2c2c;\n            font-weight: bold;\n        }\n\n        .parameters-table2 {\n            width: 100%;\n            min-width: 1000px;\n            border-collapse: collapse;\n            margin-top: 0px;\n        }\n\n        .parameters-table2 th, .parameters-table2 td {\n            border-top: 1.2px solid #a6a6a6;\n            border-bottom: 1.2px solid #a6a6a6;\n            border-left: none;\n            border-right: none;\n            padding: 5px 2px;\n            text-align: center;\n            font-size: 16px;\n            line-height: 16px;\n        }\n\n        .parameters-table2 th {\n            background-color: #f2f2f2;\n            color: #2c2c2c;\n            font-weight: bold;\n        }\n\n        .parameters-table2 .bg-gray {\n            background-color: #f2f2f2;\n        }\n\n        .options-table-wrapper2 {\n            overflow-x: auto;\n            -webkit-overflow-scrolling: touch;\n            margin-top: 0px;\n        }\n\n        .instruction-container {\n            display: flex;\n            justify-content: space-between;\n            align-items: flex-start;\n            gap: 10px;\n            margin-bottom: 0px;\n        }\n\n        .img-container {\n            width: 35%;\n            display: flex;\n            justify-content: center;\n        }\n\n        .text-container {\n            width: 65%;\n            font-size: 16px;\n            font-family: Arial;\n        }\n\n        .instruction-container2 {\n            display: flex;\n            justify-content: space-between;\n            align-items: flex-start;\n            gap: 10px;\n            margin-bottom: 0px;\n        }\n\n        .img-container2 {\n            width: 50%;\n            display: flex;\n            justify-content: center;\n        }\n\n        .text-container2 {\n            width: 50%;\n            display: flex;\n            justify-content: center;\n        }\n\n        @media (max-width: 768px) {\n            .parameters-table th, .parameters-table td {\n                font-size: 14px;\n                padding: 8px 4px;\n            }\n\n            .options-table th, .options-table td {\n                font-size: 14px;\n                padding: 8px 4px;\n            }\n\n            .parameters-table-wrapper {\n                overflow-x: auto;\n            }\n\n            .parameters-table2 th, .parameters-table2 td {\n                font-size: 14px;\n                padding: 8px 4px;\n            }\n\n            .parameters-table-wrapper2 {\n                overflow-x: auto;\n            }\n\n            .desktop-img {\n                display: none;\n            }\n\n            .mobile-img {\n                display: block;\n            }\n\n            .instruction-container {\n                flex-direction: column;\n                align-items: center;\n            }\n\n            .img-container, .text-container {\n                width: 100%;\n                margin-bottom: 0px;\n            }\n\n            .instruction-container2 {\n                flex-direction: column;\n                align-items: center;\n            }\n\n            .img-container2, .text-container2 {\n                width: 100%;\n                margin-bottom: 0px;\n            }\n        }\n\n        @media (max-width: 480px) {\n            .parameters-table th, .parameters-table td {\n                font-size: 12px;\n                padding: 6px 3px;\n            }\n\n            .options-table th, .options-table td {\n                font-size: 12px;\n            }\n\n            .parameters-table-wrapper {\n                overflow-x: auto;\n            }\n\n            .parameters-table2 th, .parameters-table2 td {\n                font-size: 12px;\n                padding: 6px 3px;\n            }\n\n            .parameters-table-wrapper2 {\n                overflow-x: auto;\n            }\n\n            .desktop-img {\n                display: none;\n            }\n\n            .mobile-img {\n                display: block;\n            }\n\n            .instruction-container {\n                flex-direction: column;\n            }\n\n            .instruction-container2 {\n                flex-direction: column;\n            }\n        }\n\n    \u003c\/style\u003e\n\n\u003c!-- Background --\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/UPVC2\/b.jpg\" class=\"desktop-img\" alt=\"Desktop Image 1\"\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/UPVC2\/b-p.jpg\" class=\"mobile-img\" alt=\"Mobile Image 1\"\u003e\n\u003c!-- Introduction - 3-Wire Single-Control \/ Standard --\u003e\n\u003cdiv\u003e\n    \u003ch2 class=\"section-title\"\u003eIntroduction\u003c\/h2\u003e\n    \u003cp class=\"section-description\"\u003e\n        Our electric UPVC ball valve series has been upgraded to include three larger sizes: 1-1\/4\", 1-1\/2\", and 2\". These larger valves feature a unique \u003cstrong\u003e\u003cu\u003eUS standard socket end \u0026amp; double union connection\u003c\/u\u003e\u003c\/strong\u003e—enabling exceptional ease of installation and maintenance with a simple solvent cement bond, \u003cstrong\u003e\u003cu\u003eunlike\u003c\/u\u003e\u003c\/strong\u003e threaded NPT or G connections. For other connection standards, please contact our customer service.\u003cbr\u003eThese valves utilize a \u003cstrong\u003e\u003cu\u003e3-wire single-control\u003c\/u\u003e\u003c\/strong\u003e configuration. Unlike the 2-wire auto-return model, this version does not automatically reset if power is lost; instead, it remains in its current position. The 3-wire setup includes a common wire, a constant power wire, and a single control wire. A manual override is also included for use during power outages. All valves have EPDM seals for reliable performance.\n    \u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- Applications--\u003e\n     \u003ch2 class=\"section-title2\"\u003eApplications\u003c\/h2\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/UPVC2\/a.jpg\" class=\"desktop-img\" alt=\"Desktop Image 1\"\u003e\n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/UPVC2\/a-p.jpg\" class=\"mobile-img\" alt=\"Desktop Image 2\"\u003e\n\u003c!-- Features - 3-Wire Single-Control --\u003e\n\u003cdiv\u003e\n    \u003ch2 class=\"section-title\"\u003eFeatures\u003c\/h2\u003e\n    \u003cul class=\"section-description2\"\u003e\n        \u003cli\u003e\n\u003cstrong\u003eUnion \u0026amp; Socket End:\u003c\/strong\u003e Different from standard NPT\/G threaded connections, it uses socket-gluing for sealing and integrates threaded structures, balancing connection stability with quick disassembly and maintenance needs.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eManual Function:\u003c\/strong\u003e Comes with a hex wrench as standard; allows manual valve opening and closing during power outages. \"O\"=Open, \"S\"=Close.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eIndicator Window:\u003c\/strong\u003e Built-in engraved marks directly show the valve's open\/closed status. External arrow pointing to \"0\" means fully closed; pointing to \"90\" means fully open.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003ePremium Material:\u003c\/strong\u003e Valve body made of UPVC with EPDM seals, meeting general operating requirements.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003e3-Wire Single-Control:\u003c\/strong\u003e Uses a common wire, a constant power wire, and a single control wire. Toggle the control wire to open or close the valve; the valve remains in its current position if power is lost.\u003c\/li\u003e\n    \u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/UPVC2\/3W1C.jpg\" class=\"desktop-img\" alt=\"Desktop Image 1\"\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/UPVC2\/3W1C-p.jpg\" class=\"mobile-img\" alt=\"Desktop Image 2\"\u003e\n\u003c!-- User Manual --\u003e\n\u003cdiv\u003e\n    \u003ch2 class=\"section-title\"\u003eUser Manual\u003c\/h2\u003e\n    \u003cp class=\"section-description\"\u003e\n        To learn how to use this product, please refer to the \u003ca href=\"https:\/\/file.ussolid.com\/content\/JFMSV\/Manual-%20USS-UPVC.pdf\" target=\"_blank\"\u003euser manual\u003c\/a\u003e.\n    \u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- Technical Data --\u003e\n    \u003ch2 class=\"section-title3\"\u003eTechnical Data\u003c\/h2\u003e \n    \u003cdiv class=\"parameters-table-wrapper\"\u003e\n        \u003ctable class=\"parameters-table\"\u003e\n            \u003ctbody\u003e \n                \u003ctr\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003ePort Size\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003e1 1\/4\"\u003c\/td\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003eUSS-MSV473\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003ePort\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003e2 Way\u003c\/td\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eThread\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003eNo Thread\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eConnection\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003eUnion \u0026amp; Socket End\u003c\/td\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eMax Power\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003e15W\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eSocket Inside Diameter\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003e42.2mm (US Standard)\u003c\/td\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eWith Hex Wrench\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003eYes\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eWiring\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003e3-Wire Single-Control\u003c\/td\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eManual Function\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003eYes\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eSignal feedback function\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003eNo\u003c\/td\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eIndicator Window\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003eYes\u003c\/td\u003e\n                \u003c\/tr\u003e\n\n                \u003ctr\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eBody Material\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003eUPVC\u003c\/td\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eNormal Position\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003eNo NO\/NC distinction\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eSeal Material\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003eEPDM\u003c\/td\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eTemp Range (Medium)\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003e33.8℉ to 104℉\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eWorking Voltage\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003eDC 24V\u003c\/td\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eClose\/Open Time\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003e10-12s\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eMax Torque\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003e20 N·m\u003c\/td\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eMax. Pressure\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003e232 psi\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eLife Expectancy\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003e20,000 Cycles\u003c\/td\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eIP Rating\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003eIP65\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003ePackage Size\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003e9.1\"x7.1\"x4.7\"\u003c\/td\u003e\n                   \u003ctd class=\"bg-gray\"\u003e\u003cstrong\u003eGross Weight\u003c\/strong\u003e\u003c\/td\u003e\n                   \u003ctd\u003e3.31 lb\u003c\/td\u003e\n                \u003c\/tr\u003e \n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n    \u003cp class=\"section-description\"\u003e*To view the full table on mobile, please swipe left or right on the screen.\u003c\/p\u003e\n\u003c!-- Wiring - 3-Wire Single-Control --\u003e\n\u003ch2 class=\"section-title\"\u003e3-Wire Single-Control\u003c\/h2\u003e\n\u003cdiv class=\"instruction-container\"\u003e\n    \u003cdiv class=\"img-container\"\u003e\n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Wire\/3W1C.jpg\" alt=\"\" style=\"width: 100%; height: auto;\"\u003e\n    \u003c\/div\u003e\n    \u003cdiv class=\"text-container\"\u003e\n        \u003cp class=\"section-description\"\u003e\n            This model uses a 3-wire single-control wiring method. It includes a common wire, a constant power wire, and a single control wire. Toggle the control wire to open or close the valve; the valve remains in its current position if power is lost.\n        \u003c\/p\u003e\n        \u003cul class=\"section-description2\"\u003e\n            \u003cli\u003eFor the basic version without signal feedback, simply ignore the signal wire connections shown in the diagram.\u003c\/li\u003e\n            \u003cli\u003eWire Color Coding: BK (Black), RD (Red), YW (Yellow), WT (White), BU (Blue), GN (Green), and OG (Orange).\u003c\/li\u003e\n            \u003cli\u003eUse the wiring diagram to identify the common, power, and control connections.\u003c\/li\u003e\n            \u003cli\u003eBefore manual operation, always disconnect power first.\u003c\/li\u003e\n        \u003c\/ul\u003e\n    \u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- FAQ --\u003e\n\u003cdiv\u003e\n    \u003ch2 class=\"section-title\"\u003eFAQ\u003c\/h2\u003e\n    \u003cp class=\"faq\"\u003e\u003cb\u003eProblem 1: What is unique about the connection method of this ball valve?\u003c\/b\u003e\u003c\/p\u003e\n    \u003cdiv class=\"instruction-container\"\u003e\n        \u003cdiv class=\"img-container\"\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/UPVC2\/size-2.jpg\" alt=\"\" style=\"width: 100%; height: auto;\"\u003e\n        \u003c\/div\u003e\n        \u003cdiv class=\"text-container\"\u003e\n            \u003cp class=\"section-description\"\u003e\n                The larger sizes of our ball valve series (1-1\/4\", 1-1\/2\", and 2\") come standard with \u003cstrong\u003e\u003cu\u003eSocket End ports\u003c\/u\u003e\u003c\/strong\u003e for solvent cement bonding and a \u003cstrong\u003e\u003cu\u003eUnion structure\u003c\/u\u003e\u003c\/strong\u003e for easier installation and maintenance, instead of common threaded connections such as NPT or G.\u003cbr\u003e\n                This union design allows the valve body to be installed or removed more easily for maintenance or replacement, without cutting the pipe or rotating the valve body itself.\u003cbr\u003e\n                The pipe sockets are made to a \u003cstrong\u003e\u003cu\u003eUS standard\u003c\/u\u003e\u003c\/strong\u003e. Please note that the Socket Inside Diameter (I.D.) may vary by national standard even for the same nominal size, such as 1-1\/4\". For other connection standards, including British Standard, Japanese Industrial Standard, or others, please contact our customer service team.\n            \u003c\/p\u003e\n        \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cp class=\"faq\"\u003e\u003cb\u003eProblem 2: What precautions apply to auto-return models?\u003c\/b\u003e\u003c\/p\u003e\n    \u003cp class=\"section-description\"\u003e\n        The auto-return ball valve requires a minimum power-on duration of 60 seconds (≥60s). This step is mandatory during first commissioning or after a prolonged power cut to ensure reliable auto-reset performance. Before using the manual override, always disconnect the power first. For auto-return models, please wait for a short period after power is disconnected before manual operation, as the actuator needs time to discharge; otherwise, the valve may be difficult to turn manually.\n    \u003c\/p\u003e\n\n    \u003cp class=\"faq\"\u003e\u003cb\u003eProblem 3: Does this model come with a manual function?\u003c\/b\u003e\u003c\/p\u003e\n    \u003cp class=\"section-description\"\u003e\n        \u003cstrong\u003eYes.\u003c\/strong\u003e The manual override function allows you to control the opening and closing of the valve during a power outage. A hexagonal wrench is included with the valve for this purpose.\n    \u003c\/p\u003e\n\n    \u003cp class=\"faq\"\u003e\u003cb\u003eProblem 4: What should be noted during manual operation?\u003c\/b\u003e\u003c\/p\u003e\n    \u003cp class=\"section-description\"\u003e\n        Power must be disconnected before manual operation. Turn the valve according to the \"O\" and \"S\" indicators: \"O\" = Open, \"S\" = Close. The valve should be turned fully open or fully closed; do not leave it in a middle position, as this may damage the valve. For auto-return models, wait for a short period after disconnecting power before manual operation.\n    \u003c\/p\u003e\n\n    \u003cp class=\"faq\"\u003e\u003cb\u003eProblem 5: How to read the indicator window?\u003c\/b\u003e\u003c\/p\u003e\n    \u003cp class=\"section-description\"\u003e\n        The external arrow shows the valve position. When the arrow points to \"0\", the valve is fully closed; when it points to \"90\", the valve is fully open.\n    \u003c\/p\u003e\n\n    \u003cp class=\"faq\"\u003e\u003cb\u003eProblem 6: What is a Union connection?\u003c\/b\u003e\u003c\/p\u003e\n    \u003cp class=\"section-description\"\u003e\n        A Union connection is a detachable valve structure that allows the valve body to be removed more easily for maintenance or replacement without cutting the pipe. On this product, the pipe connection ends are Socket End ports designed for solvent cement bonding.\n    \u003c\/p\u003e\n\n    \u003cp class=\"faq\"\u003e\u003cb\u003eProblem 7: What should be noted about the four main control methods?\u003c\/b\u003e\u003c\/p\u003e\n    \u003cp class=\"section-description\"\u003e\n        Please pay attention to the wiring type when purchasing. Only auto-return models will automatically return to the closed position when power is lost. Other control methods do not automatically reset after power loss and will remain in their current position.\n    \u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/body\u003e","brand":"U.S. Solid","offers":[{"title":"Default Title","offer_id":47911676281087,"sku":"JFMSV00473","price":126.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/1_e994c5be-5ae2-4c5a-ba29-8d05f9297e7b.jpg?v=1758694453"}],"url":"https:\/\/ussolid.com\/collections\/upvc-motorized-ball-valve-html.oembed?page=14","provider":"U.S. Solid","version":"1.0","type":"link"}