{"product_id":"compact-single-channel-laboratory-syringe-pump-for-infusion-and-withdrawal","title":"Compact Single Channel Laboratory Syringe Pump for Infusion and Withdrawal","description":"\u003cstyle\u003e\n  .options-section {\n    margin: 30px 0 20px;\n    font-family: Arial;\n}\n\n.options-card {\n    padding: 25px 30px;\n    border: 1px solid #f0f0f0;\n    background-color: #fafafa;\n    text-align: center;\n    border-radius: 8px;\n}\n\n.options-title {\n    font-size: 20px;\n    margin-bottom: 10px;\n    color: #333;\n    font-weight: bold;\n}\n\n.options-description {\n    font-size: 15px;\n    color: #666;\n    margin-bottom: 20px;\n    line-height: 1.5;\n}\n\n.options-btn {\n    display: inline-block;\n    padding: 15px 40px;\n    background-color: #2aa79b !important; \n    color: #FFFFFF !important;\n    text-decoration: none !important;\n    border-radius: 50px !important;\n    font-weight: bold !important;\n    box-shadow: 0 4px 6px rgba(0,0,0,0.1) !important;\n    transition: all 0.3s ease !important;\n    border: none !important;\n    cursor: pointer !important;\n    font-size: 16px !important;\n    letter-spacing: 0.5px !important;\n}\n\n.options-btn:hover {\n    background-color: #239087 !important;  \n    color: #FFFFFF !important;\n    transform: translateY(-2px) !important;\n    box-shadow: 0 6px 12px rgba(0,0,0,0.15) !important;\n}\n\n.options-btn:active {\n    background-color: #1e7f77 !important;  \n    color: #FFFFFF !important;\n    transform: translateY(0) !important;\n    box-shadow: 0 2px 4px rgba(0,0,0,0.1) !important;\n}\n  .faq-question {\n    background-color: #f2f2f2;\n    padding: 6px 8px;\n    margin: 15px 0 5px;\n    font-size: 16px;\n    line-height: 20px;\n    font-weight: bold;\n    font-family: Arial;\n    color: #000;\n}\n  .section-title {\n    font-size: 22px;\n    line-height: 22px;\n    font-weight: bold;\n    margin: 15px 0 5px;\n    font-family: Arial;\n    color: #000;\n  }\n\n  .section-title3 {\n    font-size: 22px;\n    line-height: 22px;\n    font-weight: bold;\n    margin: 15px 0 10px;\n    font-family: Arial;\n    color: #000;\n  }\n\n  .section-description {\n    font-size: 16px;\n    line-height: 26px;\n    margin-bottom: 5px;\n    margin-top: 0;\n    color: black;\n    font-family: Arial;\n  }\n\n  .section-description2 {\n    font-size: 16px;\n    line-height: 26px;\n    margin: 0;\n    font-family: Arial;\n    color: black;\n    padding-left: 22px;\n  }\n\n  .parameters-table-wrapper {\n    overflow-x: auto;\n    -webkit-overflow-scrolling: touch;\n    margin-top: 0;\n  }\n\n  .parameters-table {\n    width: 100%;\n    min-width: 600px;\n    border-collapse: collapse;\n    margin-top: 0;\n    background-color: #fff;\n    font-family: Arial;\n  }\n\n  .parameters-table th,\n  .parameters-table td {\n    border-top: 1.2px solid #a6a6a6;\n    border-bottom: 1.2px solid #a6a6a6;\n    border-left: none;\n    border-right: none;\n    padding: 6px 5px;\n    text-align: left;\n    font-size: 16px;\n    line-height: 20px;\n    color: #000;\n  }\n\n  .parameters-table th {\n    background-color: #f2f2f2;\n    color: #2c2c2c;\n    font-weight: bold;\n  }\n\n  .mobile-scroll-note {\n    font-family: Arial;\n    font-size: 13px;\n    color: #666;\n    margin-bottom: 8px;\n    margin-top: 0;\n  }\n\n  @media (max-width: 768px) {\n    .parameters-table th,\n    .parameters-table td {\n      font-size: 14px;\n      padding: 8px 4px;\n    }\n  }\n\n  @media (max-width: 480px) {\n    .parameters-table th,\n    .parameters-table td {\n      font-size: 12px;\n      padding: 6px 3px;\n    }\n  }\n\u003c\/style\u003e\n\u003ch2 class=\"section-title\"\u003eIntroduction\u003c\/h2\u003e\n\u003cp class=\"section-description\"\u003e\u003cspan\u003eFeaturing an exceptionally low minimum flow rate of just 0.764 nL\/min, this U.S.Solid single-channel syringe pump is designed for accurate liquid delivery and withdrawal in laboratory environments. Supporting syringe sizes from 10 μL to 100 mL, the pump delivers an exceptionally wide flow range while maintaining precise control over volume and speed. Equipped with five operating modes, users can perform infusion, withdraw, withdraw-then-infusion, infusion-then-withdraw, and cyclic infuse\/withdraw operation. With a rated linear force of 180 N, this syringe pump provides stable and dependable operation across a broad range of laboratory fluid transfer applications. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 class=\"section-title\"\u003eFeatures\u003c\/h2\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/LP012-FEATURE.png?v=1782114196\" alt=\"\" style=\"width: 90%; max-width: 90%;\"\u003e\u003c\/p\u003e\n\u003ch2 class=\"section-title\"\u003eMore Details\u003c\/h2\u003e\n\u003cul class=\"section-description2\"\u003e\n\u003cli\u003eDelivers flow rates from 0.764 nL\/min to 88.25 mL\/min for precise micro-volume and general laboratory fluid handling.\u003c\/li\u003e\n\u003cli\u003eSupports five operating modes, including infuse, withdraw, withdraw-then-infuse, infuse-then-withdraw, and cyclic \u003cspan\u003einfuse\/withdraw \u003c\/span\u003eoperation.\u003c\/li\u003e\n\u003cli\u003eAchieves high-precision liquid delivery with 0.156 μm stroke resolution and up to ±0.5% accuracy.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"section-title3\"\u003ePacking List\u003c\/h2\u003e\n\u003cp class=\"section-description\"\u003e\u003cspan\u003e\u003cspan class=\"\"\u003eSyringe Pump *1, Power Cable *1, Syringe *2.\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 class=\"section-title3\"\u003eTechnical Data\u003c\/h2\u003e\n\u003cp class=\"mobile-scroll-note\"\u003e\u003cspan style=\"margin-right: 5px;\"\u003e↔️\u003c\/span\u003e \u003cem\u003eScroll left or right to view full details\u003c\/em\u003e\u003c\/p\u003e\n\u003cdiv class=\"parameters-table-wrapper\"\u003e\n\u003ctable class=\"parameters-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSKU\u003c\/th\u003e\n\u003ctd\u003eJFSP00001\u003c\/td\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003ctd\u003eUSS-SP00001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePump Type\u003c\/th\u003e\n\u003ctd\u003eSingle-Channel Infuse\/Withdraw Syringe Pump\u003c\/td\u003e\n\u003cth\u003eChannels\u003c\/th\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFlow Rate Range\u003c\/th\u003e\n\u003ctd\u003e0.764 nL\/min - 88.25 mL\/min\u003c\/td\u003e\n\u003cth\u003eCompatible Syringe Size\u003c\/th\u003e\n\u003ctd\u003e10 μL - 100 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating Modes\u003c\/th\u003e\n\u003ctd\u003eInfuse, Withdraw, Withdraw\u003cspan\u003e-then-\u003c\/span\u003eInfuse, Infuse\u003cspan\u003e-then-\u003c\/span\u003eWithdraw, \u003cspan\u003eCyclic infuse\/withdraw operation\u003c\/span\u003e\n\u003c\/td\u003e\n\u003cth\u003eMaximum Stroke\u003c\/th\u003e\n\u003ctd\u003e140 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStroke Resolution\u003c\/th\u003e\n\u003ctd\u003e0.156 μm\u003c\/td\u003e\n\u003cth\u003eLinear Speed\u003c\/th\u003e\n\u003ctd\u003e7.94 μm\/min - 79.4 mm\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDisplay\u003c\/th\u003e\n\u003ctd\u003eLCD Screen\u003c\/td\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003ctd\u003e\n\u003cspan\u003eError \u003c\/span\u003e\u003cspan lang=\"EN-US\"\u003e≤±0.5% \u003cspan class=\"\"\u003e(when the stroke is at least 30% of the maximum stroke)\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLinear Force\u003c\/th\u003e\n\u003ctd\u003e180 N\u003c\/td\u003e\n\u003cth\u003eCommunication Interface\u003c\/th\u003e\n\u003ctd\u003eRS485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCalibration Function\u003c\/th\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003cth\u003eMemory Function\u003c\/th\u003e\n\u003ctd\u003ePower-Off Memory\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower Supply\u003c\/th\u003e\n\u003ctd\u003eAC 90-260V, 30W\u003c\/td\u003e\n\u003cth\u003eNet Weight\u003c\/th\u003e\n\u003ctd\u003e3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e265 × 154 × 144 mm\u003c\/td\u003e\n\u003cth\u003eOperating Temperature\u003c\/th\u003e\n\u003ctd\u003e0°C - 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating Humidity\u003c\/th\u003e\n\u003ctd\u003e\u0026lt;80% RH\u003c\/td\u003e\n\u003cth\u003eSyringe Selection\u003c\/th\u003e\n\u003ctd\u003eBuilt-in Syringe List \u0026amp; Direct Inner Diameter Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch2 class=\"section-title\"\u003eFAQ\u003c\/h2\u003e\n\u003cp class=\"faq-question\"\u003e1. Can I use syringes from brands that are not listed in the pump's built-in library?\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003eYes. The pump includes a built-in syringe list and also supports direct syringe inner diameter input, allowing users to work with compatible custom syringes.\u003c\/p\u003e\n\u003cp class=\"faq-question\"\u003e2. What happens if the syringe becomes blocked during operation?\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003eIf a blockage is detected, the pump automatically stops and displays a \"Stall\" warning to protect the system. After the issue is resolved, the warning can be cleared and normal operation resumed.\u003c\/p\u003e\n\u003cp class=\"faq-question\"\u003e3. Can this syringe pump be calibrated for better accuracy?\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003eYes. The pump supports calibration, helping improve dispensing accuracy for laboratory applications.\u003c\/p\u003e\n\u003cp class=\"faq-question\"\u003e4. Will the pump save settings after power-off?\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003eYes. The pump includes a power-off memory function, allowing it to retain operating parameters after shutdown or power interruption.\u003c\/p\u003e\n\u003cp class=\"faq-question\"\u003e5. Can this syringe pump be used for clinical or medical infusion?\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003eNo. This syringe pump is intended for laboratory research use only and is not suitable for clinical applications.\u003c\/p\u003e\n\u003ch2 class=\"section-title3\"\u003eAll Options\u003c\/h2\u003e\n\u003cdiv class=\"options-section\"\u003e\n\u003cdiv class=\"options-card\"\u003e\n\u003ch3 class=\"options-title\"\u003eExplore Our Full Range of Syringe Pump Options\u003c\/h3\u003e\n\u003cp class=\"options-description\"\u003eWe offer a variety of models with different flow rates, channel numbers, accuracy, and linear force to meet your specific fluid transfer requirements.\u003c\/p\u003e\n\u003ca class=\"options-btn\" href=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFSP\/JFSP-options-101.html\" target=\"_blank\"\u003e VIEW MODEL SELECTION TABLE \u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"U.S. Solid","offers":[{"title":"Default Title","offer_id":48654999978239,"sku":"JFSP00001","price":1399.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/1_a90ca045-b14f-438d-9640-5ea43fd05bbf.jpg?v=1781154500","url":"https:\/\/ussolid.com\/de\/products\/compact-single-channel-laboratory-syringe-pump-for-infusion-and-withdrawal","provider":"U.S. Solid","version":"1.0","type":"link"}