{"product_id":"halogen-moisture-analyzer-40-230-c-drying-range-124-g-capacity-0-001-g-0-01-readability-5-in-touchscreen-rs232-moisture-balance","title":"Halogen Moisture Analyzer, 40-230 °C Drying Range, 124 g Capacity, 0.001 g\/0.01% Readability, 5-in Touchscreen, RS232 Moisture Balance","description":"\u003cbody\u003e\n\u003cstyle\u003e@media only screen and (max-width:600px){.desktop-only{display:none!important}.mobile-only{display:block!important}}@media only screen and (min-width:601px){.mobile-only{display:none!important}}\u003c\/style\u003e\n\u003cdiv class=\"desktop-only\"\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFVM\/coverimage.png\" alt=\"Halogen moisture analyzer cover image\" style=\"display:block;width:100%;height:auto;border:0;\"\u003e\u003cp style=\"font-size:22px;font-family:Arial;text-align:left;margin-top:0;margin-bottom:10px;color:black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:26px;margin:10px 0 0;color:black;font-family:Arial;\"\u003eThe U.S. Solid USS-VM00004-124G halogen moisture analyzer provides a 40 to 230 deg C drying range for loss-on-drying methods, including procedures with setpoints above 200 deg C. It combines sample heating and weighing to calculate moisture and solids content for food powders, grain, feed, plastic pellets and other suitable laboratory materials.\u003cbr\u003e\u003cbr\u003eReview initial and final sample weights, dry basis and wet basis ratios, temperature and elapsed time. User permissions and custom sample identifiers help organize shared testing workflows. Select the temperature and endpoint for the material; mass loss can include volatile substances other than water, and readability describes display increments rather than measurement accuracy.\u003c\/p\u003e\n\u003cdiv style=\"flex:1;padding:0;font-family:Arial;\"\u003e\n\u003cp style=\"font-size:22px;text-align:left;margin-top:20px;margin-bottom:10px;color:black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFVM\/features.png\" alt=\"Halogen moisture analyzer features\" style=\"display:block;width:100%;height:auto;border:0;\"\u003e\u003cp style=\"font-size:22px;text-align:left;margin-top:20px;margin-bottom:10px;color:black;\"\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFVM\/applications.png\" alt=\"Halogen moisture analyzer applications\" style=\"display:block;width:100%;height:auto;border:0;\"\u003e\u003cp style=\"font-size:22px;text-align:left;margin-top:20px;margin-bottom:10px;color:black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"width:100%;overflow-x:auto;\"\u003e\u003ctable style=\"border-collapse:collapse;border:0;width:100%;font-family:Arial;overflow-x:auto;background-color:#FFFFFF;\"\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003eUSS-VM00004-124G\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eCapacity\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e124 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eWeighing Readability\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e0.001 g\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eMoisture Readability\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e0.01%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eWeighing Repeatability\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003eStandard deviation ≤3d (d=0.001 g)\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eWeighing Sensor\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003eElectromagnetic force\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eNet Weight\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e8.8 kg\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eHeating Source\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e350 W halogen lamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eTemperature Setting Range\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e40–230 °C (104–446 °F)\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eTemperature Resolution \/ Setting Step\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e0.1 °C \/ 0.1 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eTemperature Sensor \/ Control\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003ePT-1000 \/ PID\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003ePower Supply\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e110 V AC, 60 Hz, grounded US plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eMaximum Instrument Input\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e500 W\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eDisplay\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e5 in color touchscreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eHeating Programs\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003eStandard, gentle, rapid, step\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eStop Modes\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003eAutomatic, timed, manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eTimed Mode Duration\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e1–99 min; 1 second setting increments\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eMethod Storage\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e96 custom methods\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eResult Storage\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003eUp to 2004 completed records\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eUSB Record Backup\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003eUp to 2000 records per HTML export\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eSample Pan Diameter\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e90 mm\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eHeating Chamber Height\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e24.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eInterfaces\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003eRS-232; USB record backup\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eOperating Temperature\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e1–38 °C; ideally 18–25 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eDimensions\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e23.4 × 35 × 20.5 cm\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eCommon Series Features\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003eLive drying curve; user permissions; custom sample identification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cdiv data-section=\"faq-warning\" style=\"width:100%;box-sizing:border-box;font-family:Arial;margin-top:24px;\"\u003e\n  \u003cp style=\"font-size:22px;text-align:left;margin:0 0 10px;color:black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n  \u003cdiv style=\"border-top:1px solid #d9d9d9;border-bottom:1px solid #d9d9d9;\"\u003e\n    \u003cdiv style=\"padding:12px 0;border-bottom:1px solid #e5e5e5;\"\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0 0 4px;color:black;\"\u003e\u003cstrong\u003eHow should the analyzer be prepared before a measurement?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0;color:black;\"\u003ePlace it on a firm, level bench, install a clean and dry sample pan, allow at least 30 minutes of powered warm-up, and check or calibrate the weighing system as needed.\u003c\/p\u003e\n\u003c\/div\u003e\n    \u003cdiv style=\"padding:12px 0;border-bottom:1px solid #e5e5e5;\"\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0 0 4px;color:black;\"\u003e\u003cstrong\u003eWhich heating mode should be selected?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0;color:black;\"\u003eUse standard heating for routine samples, gentle heating for heat-sensitive materials, rapid heating for suitable high-moisture samples, and step heating when the validated method requires staged drying.\u003c\/p\u003e\n\u003c\/div\u003e\n    \u003cdiv style=\"padding:12px 0;border-bottom:1px solid #e5e5e5;\"\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0 0 4px;color:black;\"\u003e\u003cstrong\u003eWhy can results vary between repeated tests?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0;color:black;\"\u003eDifferences in sample uniformity, sample amount, preparation, starting chamber conditions, temperature, heating program, or endpoint can change the result. Keep these conditions consistent when comparing tests.\u003c\/p\u003e\n\u003c\/div\u003e\n    \u003cdiv style=\"padding:12px 0;border-bottom:1px solid #e5e5e5;\"\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0 0 4px;color:black;\"\u003e\u003cstrong\u003eDoes the displayed moisture result measure water only?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0;color:black;\"\u003eNot necessarily. The result is based on mass lost during heating and may include volatile substances other than water. Validate the method against an appropriate reference method when water-specific results are required.\u003c\/p\u003e\n\u003c\/div\u003e\n    \u003cdiv style=\"padding:12px 0;\"\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0 0 4px;color:black;\"\u003e\u003cstrong\u003eHow should the analyzer be cleaned?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0;color:black;\"\u003eSwitch off, unplug, and allow the instrument to cool completely. Clean removable parts and exterior surfaces with a soft, lightly dampened lint-free cloth. Do not immerse the instrument, spray liquid onto it, or use abrasive cleaners or organic solvents.\u003c\/p\u003e\n\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cp style=\"font-size:22px;text-align:left;margin:24px 0 10px;color:#9b1c1c;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n  \u003cdiv style=\"box-sizing:border-box;border-left:5px solid #d97706;background-color:#fff7e6;padding:14px 16px;color:black;\"\u003e\n    \u003cul style=\"font-size:16px;line-height:24px;margin:0;padding-left:22px;\"\u003e\n      \u003cli style=\"margin-bottom:8px;\"\u003eUse only the specified 110 V AC, 60 Hz supply and a grounded US power cord. Do not operate the analyzer with damaged wiring or allow liquid to enter the housing or connectors.\u003c\/li\u003e\n      \u003cli style=\"margin-bottom:8px;\"\u003eThe heater, chamber, sample pan, and sample can remain hot after testing. Keep ventilation openings clear, maintain at least 1 m (39.4 in) of overhead clearance, and use suitable tools and heat protection.\u003c\/li\u003e\n      \u003cli style=\"margin-bottom:8px;\"\u003eDo not test explosive materials or samples that may react dangerously. Flammable, solvent-containing, toxic, or corrosive samples require a documented safety assessment and suitable extraction before testing.\u003c\/li\u003e\n      \u003cli style=\"margin-bottom:8px;\"\u003eDo not exceed the instrument capacity. Taring does not increase capacity, and a 100 g calibration weight must never be placed on a 62 g model.\u003c\/li\u003e\n      \u003cli\u003eSwitch off, unplug, and allow the analyzer to cool before cleaning, moving, or connecting accessories. Do not open the housing or attempt internal repairs.\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mobile-only\"\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFVM\/coverimage.png\" alt=\"Halogen moisture analyzer cover image\" style=\"display:block;width:100%;height:auto;border:0;\"\u003e\u003cp style=\"font-size:22px;text-align:left;margin-top:0;margin-bottom:10px;color:black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:26px;margin:0;color:black;font-family:Arial;\"\u003eThe U.S. Solid USS-VM00004-124G halogen moisture analyzer provides a 40 to 230 deg C drying range for loss-on-drying methods, including procedures with setpoints above 200 deg C. It combines sample heating and weighing to calculate moisture and solids content for food powders, grain, feed, plastic pellets and other suitable laboratory materials.\u003cbr\u003e\u003cbr\u003eReview initial and final sample weights, dry basis and wet basis ratios, temperature and elapsed time. User permissions and custom sample identifiers help organize shared testing workflows. Select the temperature and endpoint for the material; mass loss can include volatile substances other than water, and readability describes display increments rather than measurement accuracy.\u003c\/p\u003e\n\u003cdiv style=\"flex:1;padding:0;font-family:Arial;\"\u003e\n\u003cp style=\"font-size:22px;text-align:left;margin-top:20px;margin-bottom:10px;color:black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFVM\/features.png\" alt=\"Halogen moisture analyzer features\" style=\"display:block;width:100%;height:auto;border:0;\"\u003e\u003cp style=\"font-size:22px;text-align:left;margin-top:20px;margin-bottom:10px;color:black;\"\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFVM\/applications.png\" alt=\"Halogen moisture analyzer applications\" style=\"display:block;width:100%;height:auto;border:0;\"\u003e\u003cp style=\"font-size:22px;text-align:left;margin-top:20px;margin-bottom:10px;color:black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"width:100%;overflow-x:auto;\"\u003e\u003ctable style=\"border-collapse:collapse;border:0;width:100%;font-family:Arial;overflow-x:auto;background-color:#FFFFFF;\"\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003eUSS-VM00004-124G\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eCapacity\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e124 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eWeighing Readability\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e0.001 g\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eMoisture Readability\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e0.01%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eWeighing Repeatability\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003eStandard deviation ≤3d (d=0.001 g)\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eWeighing Sensor\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003eElectromagnetic force\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eNet Weight\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e8.8 kg\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eHeating Source\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e350 W halogen lamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eTemperature Setting Range\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e40–230 °C (104–446 °F)\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eTemperature Resolution \/ Setting Step\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e0.1 °C \/ 0.1 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eTemperature Sensor \/ Control\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003ePT-1000 \/ PID\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003ePower Supply\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e110 V AC, 60 Hz, grounded US plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eMaximum Instrument Input\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e500 W\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eDisplay\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e5 in color touchscreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eHeating Programs\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003eStandard, gentle, rapid, step\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eStop Modes\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003eAutomatic, timed, manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eTimed Mode Duration\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e1–99 min; 1 second setting increments\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eMethod Storage\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e96 custom methods\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eResult Storage\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003eUp to 2004 completed records\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eUSB Record Backup\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003eUp to 2000 records per HTML export\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eSample Pan Diameter\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e90 mm\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eHeating Chamber Height\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e24.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eInterfaces\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003eRS-232; USB record backup\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eOperating Temperature\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e1–38 °C; ideally 18–25 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eDimensions\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e23.4 × 35 × 20.5 cm\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eCommon Series Features\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003eLive drying curve; user permissions; custom sample identification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cdiv data-section=\"faq-warning\" style=\"width:100%;box-sizing:border-box;font-family:Arial;margin-top:24px;\"\u003e\n  \u003cp style=\"font-size:22px;text-align:left;margin:0 0 10px;color:black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n  \u003cdiv style=\"border-top:1px solid #d9d9d9;border-bottom:1px solid #d9d9d9;\"\u003e\n    \u003cdiv style=\"padding:12px 0;border-bottom:1px solid #e5e5e5;\"\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0 0 4px;color:black;\"\u003e\u003cstrong\u003eHow should the analyzer be prepared before a measurement?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0;color:black;\"\u003ePlace it on a firm, level bench, install a clean and dry sample pan, allow at least 30 minutes of powered warm-up, and check or calibrate the weighing system as needed.\u003c\/p\u003e\n\u003c\/div\u003e\n    \u003cdiv style=\"padding:12px 0;border-bottom:1px solid #e5e5e5;\"\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0 0 4px;color:black;\"\u003e\u003cstrong\u003eWhich heating mode should be selected?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0;color:black;\"\u003eUse standard heating for routine samples, gentle heating for heat-sensitive materials, rapid heating for suitable high-moisture samples, and step heating when the validated method requires staged drying.\u003c\/p\u003e\n\u003c\/div\u003e\n    \u003cdiv style=\"padding:12px 0;border-bottom:1px solid #e5e5e5;\"\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0 0 4px;color:black;\"\u003e\u003cstrong\u003eWhy can results vary between repeated tests?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0;color:black;\"\u003eDifferences in sample uniformity, sample amount, preparation, starting chamber conditions, temperature, heating program, or endpoint can change the result. Keep these conditions consistent when comparing tests.\u003c\/p\u003e\n\u003c\/div\u003e\n    \u003cdiv style=\"padding:12px 0;border-bottom:1px solid #e5e5e5;\"\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0 0 4px;color:black;\"\u003e\u003cstrong\u003eDoes the displayed moisture result measure water only?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0;color:black;\"\u003eNot necessarily. The result is based on mass lost during heating and may include volatile substances other than water. Validate the method against an appropriate reference method when water-specific results are required.\u003c\/p\u003e\n\u003c\/div\u003e\n    \u003cdiv style=\"padding:12px 0;\"\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0 0 4px;color:black;\"\u003e\u003cstrong\u003eHow should the analyzer be cleaned?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0;color:black;\"\u003eSwitch off, unplug, and allow the instrument to cool completely. Clean removable parts and exterior surfaces with a soft, lightly dampened lint-free cloth. Do not immerse the instrument, spray liquid onto it, or use abrasive cleaners or organic solvents.\u003c\/p\u003e\n\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cp style=\"font-size:22px;text-align:left;margin:24px 0 10px;color:#9b1c1c;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n  \u003cdiv style=\"box-sizing:border-box;border-left:5px solid #d97706;background-color:#fff7e6;padding:14px 16px;color:black;\"\u003e\n    \u003cul style=\"font-size:16px;line-height:24px;margin:0;padding-left:22px;\"\u003e\n      \u003cli style=\"margin-bottom:8px;\"\u003eUse only the specified 110 V AC, 60 Hz supply and a grounded US power cord. Do not operate the analyzer with damaged wiring or allow liquid to enter the housing or connectors.\u003c\/li\u003e\n      \u003cli style=\"margin-bottom:8px;\"\u003eThe heater, chamber, sample pan, and sample can remain hot after testing. Keep ventilation openings clear, maintain at least 1 m (39.4 in) of overhead clearance, and use suitable tools and heat protection.\u003c\/li\u003e\n      \u003cli style=\"margin-bottom:8px;\"\u003eDo not test explosive materials or samples that may react dangerously. Flammable, solvent-containing, toxic, or corrosive samples require a documented safety assessment and suitable extraction before testing.\u003c\/li\u003e\n      \u003cli style=\"margin-bottom:8px;\"\u003eDo not exceed the instrument capacity. Taring does not increase capacity, and a 100 g calibration weight must never be placed on a 62 g model.\u003c\/li\u003e\n      \u003cli\u003eSwitch off, unplug, and allow the analyzer to cool before cleaning, moving, or connecting accessories. Do not open the housing or attempt internal repairs.\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/body\u003e","brand":"U.S. Solid","offers":[{"title":"Default Title","offer_id":49230414643455,"sku":"JFVM00004-124G","price":2472.96,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/1_135daedd-60b4-4bd7-942c-4c1edde6f53b.png?v=1789626650","url":"https:\/\/ussolid.com\/el\/products\/halogen-moisture-analyzer-40-230-c-drying-range-124-g-capacity-0-001-g-0-01-readability-5-in-touchscreen-rs232-moisture-balance","provider":"U.S. Solid","version":"1.0","type":"link"}