{"product_id":"halogen-moisture-analyzer-40-200-c-62-g-capacity-0-01-g-0-01-readability-5-in-touchscreen-rs232-for-food-grain-and-lab-testing","title":"Halogen Moisture Analyzer, 40-200 °C, 62 g Capacity, 0.01 g\/0.01% Readability, 5 in Touchscreen, RS232, for Food, Grain and Lab Testing","description":"\u003cbody\u003e\n\u003cstyle\u003e@media only screen and (max-width:600px){.desktop-only{display:none!important}.mobile-only{display:block!important}}@media only screen and (min-width:601px){.mobile-only{display:none!important}}\u003c\/style\u003e\n\u003cdiv class=\"desktop-only\"\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFVM\/coverimage.png\" alt=\"Halogen moisture analyzer cover image\" style=\"display:block;width:100%;height:auto;border:0;\"\u003e\u003cp style=\"font-size:22px;font-family:Arial;text-align:left;margin-top:0;margin-bottom:10px;color:black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:26px;margin:10px 0 0;color:black;font-family:Arial;\"\u003eThe U.S. Solid USS-VM00006 halogen moisture analyzer measures sample mass loss during drying, with a 62 g capacity, 40 to 200 deg C range, 0.01 g weighing readability and 0.01 percent moisture readability. An HBM strain gauge sensor measures sample mass, while a PT1000 sensor monitors temperature.\u003cbr\u003e\u003cbr\u003eView drying curves on the 5 in touchscreen, save 96 methods and 2004 test records, and transfer data using a compatible USB-C flash drive. Supports a compatible RS232 printer; operates on 110 V AC, 60 Hz with a US plug.\u003c\/p\u003e\n\u003cdiv style=\"flex:1;padding:0;font-family:Arial;\"\u003e\n\u003cp style=\"font-size:22px;text-align:left;margin-top:20px;margin-bottom:10px;color:black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFVM\/features.png\" alt=\"Halogen moisture analyzer features\" style=\"display:block;width:100%;height:auto;border:0;\"\u003e\u003cp style=\"font-size:22px;text-align:left;margin-top:20px;margin-bottom:10px;color:black;\"\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFVM\/applications.png\" alt=\"Halogen moisture analyzer applications\" style=\"display:block;width:100%;height:auto;border:0;\"\u003e\u003cp style=\"font-size:22px;text-align:left;margin-top:20px;margin-bottom:10px;color:black;\"\u003e\u003cstrong\u003eCE CERTIFICATION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/CE\/CE-LVD.jpg\" alt=\"CE certification\" style=\"display:block;max-width:100%;height:auto;border:0;\"\u003e\u003cp style=\"font-size:22px;text-align:left;margin-top:20px;margin-bottom:10px;color:black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"width:100%;overflow-x:auto;\"\u003e\u003ctable style=\"border-collapse:collapse;border:0;width:100%;font-family:Arial;overflow-x:auto;background-color:#FFFFFF;\"\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003eUSS-VM00006\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eCapacity\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e62 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eWeighing Readability\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e0.01 g\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eMoisture Readability\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e0.01%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eWeighing Repeatability\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003eStandard deviation up to 3d; d = weighing readability\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eWeighing Sensor\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003eHBM strain gauge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eGlass Heater Shield\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003eNot fitted\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eMoisture \/ Solids Display Range\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e0–100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eHeating Source\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e350 W halogen lamp\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eTemperature Setting Range\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e40–200 °C (104–392 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eTemperature Resolution \/ Setting Step\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e0.1 °C \/ 0.1 °C\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eTemperature Sensor \/ Control\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003ePT1000 \/ PID\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003ePower Supply\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e110 V AC, 60 Hz, grounded US plug\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eMaximum Instrument Input\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e500 W (distinct from lamp power)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eDisplay\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e5 in color touchscreen\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eHeating Programs\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003eStandard, gentle, rapid, step\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eStopping Modes\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003eAutomatic, timed, manual\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eTimed Mode Duration\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e1–99 min; 1-second setting increments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eMethod Storage\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003eUp to 96 custom methods\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eResult Storage\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003eUp to 2004 completed records\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eUSB Data Port\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003eUSB-C data import\/export; up to 2000 HTML records per export\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eCalibration\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003eExternal weight calibration; use model-specific prompted mass within capacity; separate compatible temperature calibrator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eStabilization Time\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003eNone specified\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eHeating Chamber Opening Method\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003eManual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eSample Pan Diameter\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e90 mm\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eHeating Chamber Height\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e24.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eDimensions\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e23.4 × 35 × 20.5 cm\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eInterfaces\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003eRS-232C; USB-C data import\/export\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eRS-232C Settings\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003eAsynchronous; 2400 \/ 4800 \/ 9600 \/ 19200 baud; 8 data bits, no parity, 1 stop bit (8N1); ASCII output\u003c\/td\u003e\n\u003cth style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#f0f0f0;color:black;\"\u003eOperating Ambient Temperature\u003c\/th\u003e\n\u003ctd style=\"width:100%;text-align:left;padding:5px;font-size:16px;border:0;background-color:#FFFFFF;color:black;\"\u003e1–38 °C; ideally 18–25 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cdiv data-section=\"faq-warning\" style=\"width:100%;box-sizing:border-box;font-family:Arial;margin-top:24px;\"\u003e\n  \u003cp style=\"font-size:22px;text-align:left;margin:0 0 10px;color:black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n  \u003cdiv style=\"border-top:1px solid #d9d9d9;border-bottom:1px solid #d9d9d9;\"\u003e\n    \u003cdiv style=\"padding:12px 0;border-bottom:1px solid #e5e5e5;\"\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0 0 4px;color:black;\"\u003e\u003cstrong\u003eHow should the analyzer be prepared before a measurement?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0;color:black;\"\u003ePlace it on a firm, level bench, install a clean and dry sample pan, allow at least 30 minutes of powered warm-up, and check or calibrate the weighing system as needed.\u003c\/p\u003e\n\u003c\/div\u003e\n    \u003cdiv style=\"padding:12px 0;border-bottom:1px solid #e5e5e5;\"\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0 0 4px;color:black;\"\u003e\u003cstrong\u003eWhich heating mode should be selected?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0;color:black;\"\u003eUse standard heating for routine samples, gentle heating for heat-sensitive materials, rapid heating for suitable high-moisture samples, and step heating when the validated method requires staged drying.\u003c\/p\u003e\n\u003c\/div\u003e\n    \u003cdiv style=\"padding:12px 0;border-bottom:1px solid #e5e5e5;\"\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0 0 4px;color:black;\"\u003e\u003cstrong\u003eWhy can results vary between repeated tests?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0;color:black;\"\u003eDifferences in sample uniformity, sample amount, preparation, starting chamber conditions, temperature, heating program, or endpoint can change the result. Keep these conditions consistent when comparing tests.\u003c\/p\u003e\n\u003c\/div\u003e\n    \u003cdiv style=\"padding:12px 0;border-bottom:1px solid #e5e5e5;\"\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0 0 4px;color:black;\"\u003e\u003cstrong\u003eDoes the displayed moisture result measure water only?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0;color:black;\"\u003eNot necessarily. The result is based on mass lost during heating and may include volatile substances other than water. Validate the method against an appropriate reference method when water-specific results are required.\u003c\/p\u003e\n\u003c\/div\u003e\n    \u003cdiv style=\"padding:12px 0;\"\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0 0 4px;color:black;\"\u003e\u003cstrong\u003eHow should the analyzer be cleaned?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0;color:black;\"\u003eSwitch off, unplug, and allow the instrument to cool completely. Clean removable parts and exterior surfaces with a soft, lightly dampened lint-free cloth. Do not immerse the instrument, spray liquid onto it, or use abrasive cleaners or organic solvents.\u003c\/p\u003e\n\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cp style=\"font-size:22px;text-align:left;margin:24px 0 10px;color:#9b1c1c;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n  \u003cdiv style=\"box-sizing:border-box;border-left:5px solid #d97706;background-color:#fff7e6;padding:14px 16px;color:black;\"\u003e\n    \u003cul style=\"font-size:16px;line-height:24px;margin:0;padding-left:22px;\"\u003e\n      \u003cli style=\"margin-bottom:8px;\"\u003eUse only the specified 110 V AC, 60 Hz supply and a grounded US power cord. Do not operate the analyzer with damaged wiring or allow liquid to enter the housing or connectors.\u003c\/li\u003e\n      \u003cli style=\"margin-bottom:8px;\"\u003eThe heater, chamber, sample pan, and sample can remain hot after testing. Keep ventilation openings clear, maintain at least 1 m (39.4 in) of overhead clearance, and use suitable tools and heat protection.\u003c\/li\u003e\n      \u003cli style=\"margin-bottom:8px;\"\u003eDo not test explosive materials or samples that may react dangerously. Flammable, solvent-containing, toxic, or corrosive samples require a documented safety assessment and suitable extraction before testing.\u003c\/li\u003e\n      \u003cli style=\"margin-bottom:8px;\"\u003eDo not exceed the instrument capacity. Taring does not increase capacity, and a 100 g calibration weight must never be placed on a 62 g model.\u003c\/li\u003e\n      \u003cli\u003eSwitch off, unplug, and allow the analyzer to cool before cleaning, moving, or connecting accessories. Do not open the housing or attempt internal repairs.\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\u003cp class=\"manual-download-heading\" style=\"font-size:22px;text-align:left;margin-top:20px;margin-bottom:10px;color:black;\"\u003e\u003cstrong\u003eUSER MANUAL\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"manual-download-link\" style=\"font-size:16px;line-height:26px;margin:10px 0 0;color:black;font-family:Arial;\"\u003e\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFVM\/US_Solid_VM_Manual.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eDownload the user manual (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:22px;text-align:left;margin-top:20px;margin-bottom:10px;line-height:26px;color:black;\"\u003e\u003cstrong\u003e OTHER MODELS \u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"padding:20px;border:1px solid #f0f0f0;background-color:#fafafa;text-align:center;border-radius:8px;\"\u003e\n\u003ch3 style=\"font-size:20px;margin-bottom:10px;color:#333;\"\u003eExplore Our Full Range of Halogen Moisture Analyzers\u003c\/h3\u003e\n\u003cp style=\"font-size:15px;color:#666;margin-bottom:20px;\"\u003eWe offer a variety of models with different weighing capacities and readability levels to meet your testing requirements.\u003c\/p\u003e\n\u003ca href=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFVM\/JFVM-series.html\" style=\"display:inline-block;padding:15px 40px;background-color:#7fb72c;color:#fff;text-decoration:none;border-radius:50px;font-weight:bold;box-shadow:0 4px 6px rgba(0,0,0,0.1);\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e VIEW MODEL SELECTION TABLE \u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mobile-only\"\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFVM\/coverimage.png\" alt=\"Halogen moisture analyzer cover image\" style=\"display:block;width:100%;height:auto;border:0;\"\u003e\u003cp style=\"font-size:22px;text-align:left;margin-top:0;margin-bottom:10px;color:black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:26px;margin:0;color:black;font-family:Arial;\"\u003eThe U.S. Solid USS-VM00006 halogen moisture analyzer measures sample mass loss during drying, with a 62 g capacity, 40 to 200 deg C range, 0.01 g weighing readability and 0.01 percent moisture readability. An HBM strain gauge sensor measures sample mass, while a PT1000 sensor monitors temperature.\u003cbr\u003e\u003cbr\u003eView drying curves on the 5 in touchscreen, save 96 methods and 2004 test records, and transfer data using a compatible USB-C flash drive. Supports a compatible RS232 printer; operates on 110 V AC, 60 Hz with a US plug.\u003c\/p\u003e\n\u003cdiv style=\"flex:1;padding:0;font-family:Arial;\"\u003e\n\u003cp style=\"font-size:22px;text-align:left;margin-top:20px;margin-bottom:10px;color:black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFVM\/features.png\" alt=\"Halogen moisture analyzer features\" style=\"display:block;width:100%;height:auto;border:0;\"\u003e\u003cp style=\"font-size:22px;text-align:left;margin-top:20px;margin-bottom:10px;color:black;\"\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFVM\/applications.png\" alt=\"Halogen moisture analyzer applications\" style=\"display:block;width:100%;height:auto;border:0;\"\u003e\u003cp style=\"font-size:22px;text-align:left;margin-top:20px;margin-bottom:10px;color:black;\"\u003e\u003cstrong\u003eCE CERTIFICATION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/CE\/CE-LVD.jpg\" alt=\"CE certification\" style=\"display:block;max-width:100%;height:auto;border:0;\"\u003e\u003cp style=\"font-size:22px;text-align:left;margin-top:20px;margin-bottom:10px;color:black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"width:100%;overflow-x:auto;\"\u003e\u003ctable style=\"border-collapse:collapse;border:0;width:100%;font-family:Arial;overflow-x:auto;background-color:#FFFFFF;\"\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003eUSS-VM00006\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eCapacity\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e62 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eWeighing Readability\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e0.01 g\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eMoisture Readability\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e0.01%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eWeighing Repeatability\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003eStandard deviation up to 3d; d = weighing readability\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eWeighing Sensor\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003eHBM strain gauge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eGlass Heater Shield\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003eNot fitted\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eMoisture \/ Solids Display Range\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e0–100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eHeating Source\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e350 W halogen lamp\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eTemperature Setting Range\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e40–200 °C (104–392 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eTemperature Resolution \/ Setting Step\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e0.1 °C \/ 0.1 °C\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eTemperature Sensor \/ Control\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003ePT1000 \/ PID\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003ePower Supply\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e110 V AC, 60 Hz, grounded US plug\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eMaximum Instrument Input\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e500 W (distinct from lamp power)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eDisplay\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e5 in color touchscreen\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eHeating Programs\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003eStandard, gentle, rapid, step\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eStopping Modes\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003eAutomatic, timed, manual\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eTimed Mode Duration\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e1–99 min; 1-second setting increments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eMethod Storage\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003eUp to 96 custom methods\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eResult Storage\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003eUp to 2004 completed records\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eUSB Data Port\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003eUSB-C data import\/export; up to 2000 HTML records per export\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eCalibration\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003eExternal weight calibration; use model-specific prompted mass within capacity; separate compatible temperature calibrator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eStabilization Time\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003eNone specified\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eHeating Chamber Opening Method\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003eManual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eSample Pan Diameter\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e90 mm\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eHeating Chamber Height\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e24.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom:1px dashed black;\"\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eDimensions\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e23.4 × 35 × 20.5 cm\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eInterfaces\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003eRS-232C; USB-C data import\/export\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eRS-232C Settings\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003eAsynchronous; 2400 \/ 4800 \/ 9600 \/ 19200 baud; 8 data bits, no parity, 1 stop bit (8N1); ASCII output\u003c\/td\u003e\n\u003cth style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#f0f0f0;color:black;\"\u003eOperating Ambient Temperature\u003c\/th\u003e\n\u003ctd style=\"width:100px;text-align:left;padding:5px;font-size:14px;border:0;background-color:#FFFFFF;color:black;\"\u003e1–38 °C; ideally 18–25 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cdiv data-section=\"faq-warning\" style=\"width:100%;box-sizing:border-box;font-family:Arial;margin-top:24px;\"\u003e\n  \u003cp style=\"font-size:22px;text-align:left;margin:0 0 10px;color:black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n  \u003cdiv style=\"border-top:1px solid #d9d9d9;border-bottom:1px solid #d9d9d9;\"\u003e\n    \u003cdiv style=\"padding:12px 0;border-bottom:1px solid #e5e5e5;\"\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0 0 4px;color:black;\"\u003e\u003cstrong\u003eHow should the analyzer be prepared before a measurement?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0;color:black;\"\u003ePlace it on a firm, level bench, install a clean and dry sample pan, allow at least 30 minutes of powered warm-up, and check or calibrate the weighing system as needed.\u003c\/p\u003e\n\u003c\/div\u003e\n    \u003cdiv style=\"padding:12px 0;border-bottom:1px solid #e5e5e5;\"\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0 0 4px;color:black;\"\u003e\u003cstrong\u003eWhich heating mode should be selected?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0;color:black;\"\u003eUse standard heating for routine samples, gentle heating for heat-sensitive materials, rapid heating for suitable high-moisture samples, and step heating when the validated method requires staged drying.\u003c\/p\u003e\n\u003c\/div\u003e\n    \u003cdiv style=\"padding:12px 0;border-bottom:1px solid #e5e5e5;\"\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0 0 4px;color:black;\"\u003e\u003cstrong\u003eWhy can results vary between repeated tests?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0;color:black;\"\u003eDifferences in sample uniformity, sample amount, preparation, starting chamber conditions, temperature, heating program, or endpoint can change the result. Keep these conditions consistent when comparing tests.\u003c\/p\u003e\n\u003c\/div\u003e\n    \u003cdiv style=\"padding:12px 0;border-bottom:1px solid #e5e5e5;\"\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0 0 4px;color:black;\"\u003e\u003cstrong\u003eDoes the displayed moisture result measure water only?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0;color:black;\"\u003eNot necessarily. The result is based on mass lost during heating and may include volatile substances other than water. Validate the method against an appropriate reference method when water-specific results are required.\u003c\/p\u003e\n\u003c\/div\u003e\n    \u003cdiv style=\"padding:12px 0;\"\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0 0 4px;color:black;\"\u003e\u003cstrong\u003eHow should the analyzer be cleaned?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:16px;line-height:24px;margin:0;color:black;\"\u003eSwitch off, unplug, and allow the instrument to cool completely. Clean removable parts and exterior surfaces with a soft, lightly dampened lint-free cloth. Do not immerse the instrument, spray liquid onto it, or use abrasive cleaners or organic solvents.\u003c\/p\u003e\n\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cp style=\"font-size:22px;text-align:left;margin:24px 0 10px;color:#9b1c1c;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n  \u003cdiv style=\"box-sizing:border-box;border-left:5px solid #d97706;background-color:#fff7e6;padding:14px 16px;color:black;\"\u003e\n    \u003cul style=\"font-size:16px;line-height:24px;margin:0;padding-left:22px;\"\u003e\n      \u003cli style=\"margin-bottom:8px;\"\u003eUse only the specified 110 V AC, 60 Hz supply and a grounded US power cord. Do not operate the analyzer with damaged wiring or allow liquid to enter the housing or connectors.\u003c\/li\u003e\n      \u003cli style=\"margin-bottom:8px;\"\u003eThe heater, chamber, sample pan, and sample can remain hot after testing. Keep ventilation openings clear, maintain at least 1 m (39.4 in) of overhead clearance, and use suitable tools and heat protection.\u003c\/li\u003e\n      \u003cli style=\"margin-bottom:8px;\"\u003eDo not test explosive materials or samples that may react dangerously. Flammable, solvent-containing, toxic, or corrosive samples require a documented safety assessment and suitable extraction before testing.\u003c\/li\u003e\n      \u003cli style=\"margin-bottom:8px;\"\u003eDo not exceed the instrument capacity. Taring does not increase capacity, and a 100 g calibration weight must never be placed on a 62 g model.\u003c\/li\u003e\n      \u003cli\u003eSwitch off, unplug, and allow the analyzer to cool before cleaning, moving, or connecting accessories. Do not open the housing or attempt internal repairs.\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\u003cp class=\"manual-download-heading\" style=\"font-size:22px;text-align:left;margin-top:20px;margin-bottom:10px;color:black;\"\u003e\u003cstrong\u003eUSER MANUAL\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"manual-download-link\" style=\"font-size:16px;line-height:26px;margin:10px 0 0;color:black;font-family:Arial;\"\u003e\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFVM\/US_Solid_VM_Manual.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eDownload the user manual (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:22px;text-align:left;margin-top:20px;margin-bottom:10px;line-height:26px;color:black;\"\u003e\u003cstrong\u003e OTHER MODELS \u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"padding:20px;border:1px solid #f0f0f0;background-color:#fafafa;text-align:center;border-radius:8px;\"\u003e\n\u003ch3 style=\"font-size:20px;margin-bottom:10px;color:#333;\"\u003eExplore Our Full Range of Halogen Moisture Analyzers\u003c\/h3\u003e\n\u003cp style=\"font-size:15px;color:#666;margin-bottom:20px;\"\u003eWe offer a variety of models with different weighing capacities and readability levels to meet your testing requirements.\u003c\/p\u003e\n\u003ca href=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFVM\/JFVM-series.html\" style=\"display:inline-block;padding:15px 40px;background-color:#7fb72c;color:#fff;text-decoration:none;border-radius:50px;font-weight:bold;box-shadow:0 4px 6px rgba(0,0,0,0.1);\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e VIEW MODEL SELECTION TABLE \u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/body\u003e","brand":"U.S. Solid","offers":[{"title":"Default Title","offer_id":50717747216639,"sku":"JFVM00006","price":1152.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/0_8ab3dfdc-c741-4031-9fe1-a2fa8a3c7f54.png?v=1792462573","url":"https:\/\/ussolid.com\/id\/products\/halogen-moisture-analyzer-40-200-c-62-g-capacity-0-01-g-0-01-readability-5-in-touchscreen-rs232-for-food-grain-and-lab-testing","provider":"U.S. Solid","version":"1.0","type":"link"}