{"product_id":"1-hp-cast-iron-shallow-well-jet-pump-115-230v-26-gpm-max-flow","title":"1 HP Cast Iron Shallow Well Jet Pump, 115\/230V, 26 GPM Max Flow","description":"\u003cstyle\u003e\n  .section-title {\n    font-size: 22px;\n    line-height: 24px;\n    font-weight: bold;\n    margin: 20px 0 8px;\n    font-family: Arial;\n    color: #000;\n  }\n\n  .section-title3 {\n    font-size: 22px;\n    line-height: 24px;\n    font-weight: bold;\n    margin: 20px 0 10px;\n    font-family: Arial;\n    color: #000;\n  }\n\n  .section-description {\n    font-size: 16px;\n    line-height: 26px;\n    margin: 0 0 8px;\n    color: #000;\n    font-family: Arial;\n  }\n\n  .section-description2 {\n    font-size: 16px;\n    line-height: 26px;\n    margin: 0;\n    padding-left: 22px;\n    color: #000;\n    font-family: Arial;\n  }\n\n  .faq-question {\n    background-color: #f2f2f2;\n    padding: 7px 9px;\n    margin: 15px 0 6px;\n    font-size: 16px;\n    line-height: 22px;\n    font-weight: bold;\n    font-family: Arial;\n    color: #000;\n  }\n\n  .parameters-table-wrapper {\n    overflow-x: auto;\n    -webkit-overflow-scrolling: touch;\n    margin-top: 0;\n  }\n\n  .parameters-table {\n    width: 100%;\n    min-width: 680px;\n    border-collapse: collapse;\n    margin-top: 0;\n    background-color: #fff;\n    font-family: Arial;\n  }\n\n  .parameters-table th,\n  .parameters-table td {\n    border-top: 1.2px solid #a6a6a6;\n    border-bottom: 1.2px solid #a6a6a6;\n    border-left: none;\n    border-right: none;\n    padding: 7px 6px;\n    text-align: left;\n    font-size: 16px;\n    line-height: 21px;\n    color: #000;\n    vertical-align: top;\n  }\n\n  .parameters-table th {\n    background-color: #f2f2f2;\n    color: #2c2c2c;\n    font-weight: bold;\n  }\n\n  .performance-table {\n    width: 100%;\n    min-width: 650px;\n    border-collapse: collapse;\n    background-color: #fff;\n    font-family: Arial;\n  }\n\n  .performance-table th,\n  .performance-table td {\n    border: 1px solid #b5b5b5;\n    padding: 7px 6px;\n    text-align: center;\n    font-size: 15px;\n    line-height: 20px;\n    color: #000;\n  }\n\n  .performance-table th {\n    background-color: #f2f2f2;\n    font-weight: bold;\n  }\n\n  .mobile-scroll-note {\n    font-family: Arial;\n    font-size: 13px;\n    color: #666;\n    margin-bottom: 8px;\n    margin-top: 0;\n  }\n\n  .highlight-box {\n    background-color: #f7f7f7;\n    border-left: 4px solid #2aa79b;\n    padding: 16px 18px;\n    margin: 15px 0;\n    font-family: Arial;\n  }\n\n  .warning-box {\n    background-color: #fff8e8;\n    border-left: 4px solid #e5a100;\n    padding: 16px 18px;\n    margin: 15px 0;\n    font-family: Arial;\n  }\n\n  .danger-box {\n    background-color: #fff3f3;\n    border-left: 4px solid #c62828;\n    padding: 16px 18px;\n    margin: 15px 0;\n    font-family: Arial;\n  }\n\n  .highlight-box p,\n  .warning-box p,\n  .danger-box p {\n    font-size: 16px;\n    line-height: 25px;\n    margin: 0 0 6px;\n    color: #000;\n  }\n\n  .highlight-box p:last-child,\n  .warning-box p:last-child,\n  .danger-box p:last-child {\n    margin-bottom: 0;\n  }\n\n  .step-title {\n    font-family: Arial;\n    font-size: 17px;\n    line-height: 24px;\n    font-weight: bold;\n    margin: 12px 0 4px;\n    color: #000;\n  }\n\n  .image-placeholder {\n    width: 100%;\n    min-height: 80px;\n    margin: 12px 0 18px;\n  }\n\n  @media (max-width: 768px) {\n    .parameters-table th,\n    .parameters-table td,\n    .performance-table th,\n    .performance-table td {\n      font-size: 14px;\n      padding: 7px 4px;\n    }\n  }\n\n  @media (max-width: 480px) {\n    .parameters-table th,\n    .parameters-table td,\n    .performance-table th,\n    .performance-table td {\n      font-size: 12px;\n      padding: 6px 3px;\n    }\n  }\n\u003c\/style\u003e\n\u003c!-- MAIN PRODUCT IMAGE PLACEHOLDER --\u003e\n\u003ch2 class=\"section-title\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/ChatGPT_Image_Sep_7_2026_03_43_59_PM.png?v=1788767062\" alt=\"\"\u003e\u003c\/h2\u003e\n\u003ch2 class=\"section-title\"\u003eIntroduction\u003c\/h2\u003e\n\u003cp class=\"section-description\"\u003eThe U.S. Solid \u003cstrong\u003e1 HP Shallow Well Jet Pump\u003c\/strong\u003e is designed for shallow-well water supply applications where the vertical distance from the pump to the water level is no more than \u003cstrong\u003e25 ft.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003eAt 40 PSI discharge pressure, the pump delivers up to \u003cstrong\u003e26 GPM\u003c\/strong\u003e with a 0 ft. suction lift. A factory-installed \u003cstrong\u003e30\/50 PSI automatic pressure switch\u003c\/strong\u003e starts and stops the pump according to system pressure, making it suitable for residential water systems, pressure-tank installations, irrigation, sprinkler systems, and other clear-water applications.\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003eThe single-phase motor supports \u003cstrong\u003e115 V and 230 V, 60 Hz\u003c\/strong\u003e operation and is \u003cstrong\u003efactory prewired for 115 V\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2 class=\"section-title\"\u003eApplications\u003c\/h2\u003e\n\u003c!-- APPLICATION IMAGE PLACEHOLDER --\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/WP03_APPLICATION.png?v=1788245545\" alt=\"\"\u003e\u003c\/p\u003e\n\u003ch2 class=\"section-title\"\u003eFeatures\u003c\/h2\u003e\n\u003c!-- FEATURES IMAGE PLACEHOLDER --\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/features-WP03.png?v=1788329697\" alt=\"\"\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2 class=\"section-title\"\u003eMore Details\u003c\/h2\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/WP03-more_details.png?v=1788492622\" alt=\"\"\u003e\u003c\/p\u003e\n\u003ch2 class=\"section-title\"\u003eElectrical Requirements\u003c\/h2\u003e\n\u003cp class=\"mobile-scroll-note\"\u003e\u003cspan style=\"margin-right: 5px;\"\u003e↔️\u003c\/span\u003e \u003cem\u003eScroll left or right to view full details\u003c\/em\u003e\u003c\/p\u003e\n\u003cdiv class=\"parameters-table-wrapper\"\u003e\n\u003ctable class=\"performance-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage\u003c\/th\u003e\n\u003cth\u003eMaximum Load Current\u003c\/th\u003e\n\u003cth\u003eRecommended Branch Fuse \/ Circuit Rating\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e115 V\u003c\/td\u003e\n\u003ctd\u003e17.6 A\u003c\/td\u003e\n\u003ctd\u003e30 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230 V\u003c\/td\u003e\n\u003ctd\u003e8.8 A\u003c\/td\u003e\n\u003ctd\u003e20 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2 class=\"section-title\"\u003eTechnical Data\u003c\/h2\u003e\n\u003cp class=\"mobile-scroll-note\"\u003e\u003cspan style=\"margin-right: 5px;\"\u003e↔️\u003c\/span\u003e \u003cem\u003eScroll left or right to view full details\u003c\/em\u003e\u003c\/p\u003e\n\u003cdiv class=\"parameters-table-wrapper\"\u003e\n\u003ctable class=\"parameters-table\" style=\"width: 100%; height: 524px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003cth style=\"width: 22.0913%; height: 21px;\"\u003eSKU\u003c\/th\u003e\n\u003ctd style=\"width: 25.9311%; height: 21px;\"\u003eJFWP00003\u003c\/td\u003e\n\u003cth style=\"width: 23.1116%; height: 21px;\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"width: 28.866%; height: 21px;\"\u003eUSS-WP00003\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003cth style=\"width: 22.0913%; height: 21px;\"\u003ePump Type\u003c\/th\u003e\n\u003ctd style=\"width: 25.9311%; height: 21px;\"\u003eCast Iron Shallow Well Jet Pump\u003c\/td\u003e\n\u003cth style=\"width: 23.1116%; height: 21px;\"\u003eMotor Power\u003c\/th\u003e\n\u003ctd style=\"width: 28.866%; height: 21px;\"\u003e1 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003cth style=\"width: 22.0913%; height: 21px;\"\u003eVoltage\u003c\/th\u003e\n\u003ctd style=\"width: 25.9311%; height: 21px;\"\u003e115\/230 V AC\u003c\/td\u003e\n\u003cth style=\"width: 23.1116%; height: 21px;\"\u003eFactory Voltage Setting\u003c\/th\u003e\n\u003ctd style=\"width: 28.866%; height: 21px;\"\u003e115 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003cth style=\"width: 22.0913%; height: 21px;\"\u003eFrequency\u003c\/th\u003e\n\u003ctd style=\"width: 25.9311%; height: 21px;\"\u003e60 Hz\u003c\/td\u003e\n\u003cth style=\"width: 23.1116%; height: 21px;\"\u003ePhase\u003c\/th\u003e\n\u003ctd style=\"width: 28.866%; height: 21px;\"\u003eSingle Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003cth style=\"width: 22.0913%; height: 21px;\"\u003eMotor Speed\u003c\/th\u003e\n\u003ctd style=\"width: 25.9311%; height: 21px;\"\u003e3450 RPM\u003c\/td\u003e\n\u003cth style=\"width: 23.1116%; height: 21px;\"\u003eMotor Type\u003c\/th\u003e\n\u003ctd style=\"width: 28.866%; height: 21px;\"\u003eCSIR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 42px;\"\u003e\n\u003cth style=\"width: 22.0913%; height: 42px;\"\u003eMaximum Load Current\u003c\/th\u003e\n\u003ctd style=\"width: 25.9311%; height: 42px;\"\u003e17.6 A @ 115 V \/ 8.8 A @ 230 V\u003c\/td\u003e\n\u003cth style=\"width: 23.1116%; height: 42px;\"\u003eRecommended Circuit\u003c\/th\u003e\n\u003ctd style=\"width: 28.866%; height: 42px;\"\u003e30 A @ 115 V \/ 20 A @ 230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 63px;\"\u003e\n\u003cth style=\"width: 22.0913%; height: 63px;\"\u003eMaximum Flow Rate\u003c\/th\u003e\n\u003ctd style=\"width: 25.9311%; height: 63px;\"\u003e26 GPM\u003c\/td\u003e\n\u003cth style=\"width: 23.1116%; height: 63px;\"\u003eMaximum Shutoff Pressure\u003c\/th\u003e\n\u003ctd style=\"width: 28.866%; height: 63px;\"\u003e74 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 42px;\"\u003e\n\u003cth style=\"width: 22.0913%; height: 42px;\"\u003eMaximum Shallow Well Depth\u003c\/th\u003e\n\u003ctd style=\"width: 25.9311%; height: 42px;\"\u003e25 ft.\u003c\/td\u003e\n\u003cth style=\"width: 23.1116%; height: 42px;\"\u003ePressure Switch\u003c\/th\u003e\n\u003ctd style=\"width: 28.866%; height: 42px;\"\u003e30 PSI ON \/ 50 PSI OFF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003cth style=\"width: 22.0913%; height: 21px;\"\u003eSuction Port\u003c\/th\u003e\n\u003ctd style=\"width: 25.9311%; height: 21px;\"\u003e1-1\/4 in. FNPT\u003c\/td\u003e\n\u003cth style=\"width: 23.1116%; height: 21px;\"\u003eDischarge Port\u003c\/th\u003e\n\u003ctd style=\"width: 28.866%; height: 21px;\"\u003e1 in. FNPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 42px;\"\u003e\n\u003cth style=\"width: 22.0913%; height: 42px;\"\u003eLiquid Temperature Range\u003c\/th\u003e\n\u003ctd style=\"width: 25.9311%; height: 42px;\"\u003e32°F–140°F (0°C–60°C)\u003c\/td\u003e\n\u003cth style=\"width: 23.1116%; height: 42px;\"\u003eOperation\u003c\/th\u003e\n\u003ctd style=\"width: 28.866%; height: 42px;\"\u003eAutomatic with Pressure Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003cth style=\"width: 22.0913%; height: 21px;\"\u003ePump Housing\u003c\/th\u003e\n\u003ctd style=\"width: 25.9311%; height: 21px;\"\u003eCast Iron\u003c\/td\u003e\n\u003cth style=\"width: 23.1116%; height: 21px;\"\u003ePump Base\u003c\/th\u003e\n\u003ctd style=\"width: 28.866%; height: 21px;\"\u003eCast Iron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003cth style=\"width: 22.0913%; height: 21px;\"\u003eImpeller\u003c\/th\u003e\n\u003ctd style=\"width: 25.9311%; height: 21px;\"\u003eReinforced Thermoplastic\u003c\/td\u003e\n\u003cth style=\"width: 23.1116%; height: 21px;\"\u003eDiffuser\u003c\/th\u003e\n\u003ctd style=\"width: 28.866%; height: 21px;\"\u003eReinforced Thermoplastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003cth style=\"width: 22.0913%; height: 21px;\"\u003eGasket\u003c\/th\u003e\n\u003ctd style=\"width: 25.9311%; height: 21px;\"\u003eRubber\u003c\/td\u003e\n\u003cth style=\"width: 23.1116%; height: 21px;\"\u003eShaft Seal\u003c\/th\u003e\n\u003ctd style=\"width: 28.866%; height: 21px;\"\u003eMechanical Seal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 42px;\"\u003e\n\u003cth style=\"width: 22.0913%; height: 42px;\"\u003eMotor Shaft\u003c\/th\u003e\n\u003ctd style=\"width: 25.9311%; height: 42px;\"\u003eStainless Steel\u003c\/td\u003e\n\u003cth style=\"width: 23.1116%; height: 42px;\"\u003eMotor Bearings\u003c\/th\u003e\n\u003ctd style=\"width: 28.866%; height: 42px;\"\u003eBall Bearings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 41px;\"\u003e\n\u003cth style=\"width: 22.0913%; height: 41px;\"\u003eCooling\u003c\/th\u003e\n\u003ctd style=\"width: 25.9311%; height: 41px;\"\u003eFan Cooled\u003c\/td\u003e\n\u003cth style=\"width: 23.1116%; height: 41px;\"\u003eMotor Protection\u003c\/th\u003e\n\u003ctd style=\"width: 28.866%; height: 41px;\"\u003eAutomatic-Reset Thermal Overload Protector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003cth style=\"width: 22.0913%; height: 21px;\"\u003eInsulation Class\u003c\/th\u003e\n\u003ctd style=\"width: 25.9311%; height: 21px;\"\u003eClass B\u003c\/td\u003e\n\u003cth style=\"width: 23.1116%; height: 21px;\"\u003eNet Weight\u003c\/th\u003e\n\u003ctd style=\"width: 28.866%; height: 21px;\"\u003e\u003cspan\u003e45.19 lbs \/ 20.5 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch2 class=\"section-title\"\u003ePacking List\u003c\/h2\u003e\n\u003cp class=\"section-description\"\u003eShallow Well Jet Pump × 1, User Manual × 1\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e Pressure tank, piping, foot valve, check valve, fittings, electrical wiring, and other installation accessories are not included unless otherwise specified.\u003c\/p\u003e\n\u003ch2 class=\"section-title\"\u003eUser Manual\u003c\/h2\u003e\n\u003cp class=\"section-description\"\u003eFor detailed installation, electrical wiring, priming, operation, maintenance, and troubleshooting instructions, please refer to the \u003c!-- INSERT USER MANUAL URL HERE --\u003e \u003ca href=\"http:\/\/file.ussolid.com\/content\/JFWP\/WP03_Shallow_Well_Jet_Pump_Manual.pdf\" target=\"_blank\" rel=\"noopener\"\u003euser manual\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch2 class=\"section-title\"\u003eWarning\u003c\/h2\u003e\n\u003cp class=\"section-description\"\u003e1. \u003cstrong\u003eAlways verify that the motor voltage setting matches the power supply before connecting power. \u003c\/strong\u003eNever connect a 230 V power supply while the motor is configured for 115 V. Incorrect voltage may damage the motor and create a fire or electrical hazard.\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e2. \u003cstrong\u003eDo not run the pump dry.\u003c\/strong\u003e The pump housing and suction piping must be completely filled with water before the pump is started.\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e3. \u003cstrong\u003eNever operate the pump against a closed discharge. \u003c\/strong\u003eDoing so may cause water inside the pump to overheat or boil, creating hazardous pressure that could result in equipment damage, explosion, or serious scalding injury.\u003c\/p\u003e\n\u003ch2 class=\"section-title\"\u003eFAQ\u003c\/h2\u003e\n\u003cp class=\"faq-question\"\u003e1. What type of well is this pump designed for?\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003eThis pump is designed for shallow-well applications where the vertical distance between the pump and the water level is no more than \u003cstrong\u003e25 ft.\u003c\/strong\u003e If the water level is deeper than 25 ft., use a pump designed for deeper-well applications.\u003c\/p\u003e\n\u003cp class=\"faq-question\"\u003e2. Does the pump automatically turn on and off?\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003eYes. A factory-installed pressure switch automatically controls the pump based on water-system pressure. When a faucet, sprinkler, or other water outlet is opened and system pressure drops to approximately \u003cstrong\u003e30 PSI (cut-in)\u003c\/strong\u003e, the pump automatically starts. As water demand decreases and system pressure rises to approximately \u003cstrong\u003e50 PSI (cut-out)\u003c\/strong\u003e, the pump automatically stops.\u003c\/p\u003e\n\u003cp class=\"faq-question\"\u003e3. Does this pump require a pressure tank?\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003eA pressure tank is recommended for normal automatic residential water-system operation. It stores pressurized water, helps reduce frequent pump cycling, and works with the 30\/50 PSI pressure switch to provide automatic water pressure. The pressure tank is not included. \u003c\/p\u003e\n\u003cp class=\"faq-question\"\u003e4. Is the pump 115 V or 230 V?\u003c\/p\u003e\n\u003cdiv style=\"display: flex; align-items: center; gap: 24px; flex-wrap: wrap;\"\u003e\n\u003cdiv style=\"flex: 3.5 1 0; min-width: 280px;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/voltage-select.png?v=1788335840\" alt=\"115 V and 230 V voltage selector\" style=\"width: 100%; height: auto; display: block;\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"section-description\" style=\"flex: 6.5 1 0; min-width: 280px; margin: 0;\"\u003e\n\u003cp class=\"section-description\"\u003eThe motor supports both \u003cstrong\u003e115 V and 230 V, 60 Hz\u003c\/strong\u003e operation and is \u003cstrong\u003efactory prewired for 115 V\u003c\/strong\u003e. Before connecting power, always verify that the voltage selector matches the available power supply. For 230 V operation, disconnect all power, remove the rear motor cover, move the voltage selector to the 230 V position, and reinstall the cover before applying power.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp class=\"faq-question\"\u003e5. Does the pump come with a power plug?\u003c\/p\u003e\n\u003ch3 class=\"step-title\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/steps-WP03.png?v=1788492639\" alt=\"\"\u003e\u003c\/h3\u003e\n\u003cp class=\"section-description\"\u003eNo. The pump does not come with a power plug. The pump is designed for field electrical connection through the pressure switch. Power-supply conductors and grounding must be connected according to the wiring instructions above and applicable electrical codes. \u003c\/p\u003e\n\u003cp class=\"faq-question\"\u003e6. Does the pump need to be primed before use?\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003eYes. Before initial startup, completely fill the pump housing and suction piping with water. \u003cstrong\u003eNever run the pump dry.\u003c\/strong\u003e Dry running may cause overheating and damage the mechanical seal.\u003c\/p\u003e\n\u003cp class=\"faq-question\"\u003e7. Can this pump be installed outdoors?\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003eThe pump should not be installed outdoors where it is directly exposed to weather. For outdoor installations, place the pump in a suitable pump house or protective enclosure and protect it from flooding, excessive moisture, and freezing conditions. Auxiliary heat may be required where freezing is possible.\u003c\/p\u003e\n\u003cp class=\"faq-question\"\u003e8. What pipe sizes are required?\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003eThe pump has a \u003cstrong\u003e1-1\/4 in. FNPT suction port\u003c\/strong\u003e and a \u003cstrong\u003e1 in. FNPT discharge port\u003c\/strong\u003e. Suction piping should be airtight, watertight, and properly sized to minimize restriction and prevent air from entering the system.\u003c\/p\u003e\n\u003cp class=\"faq-question\"\u003e9. Can this pump be used for ponds, lakes, or cisterns?\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\u003cspan\u003eYes. The pump can be used for surface-water applications such as ponds, lakes, rivers, and cisterns, provided the suction lift is less than \u003c\/span\u003e\u003cspan\u003e25 ft\u003c\/span\u003e\u003cspan\u003e. \u003cstrong\u003eInstall an appropriate inlet screen to help prevent debris, wildlife, or other objects from entering the suction pipe.\u003c\/strong\u003e \u003c\/span\u003e\u003cspan\u003eDo not use untreated surface water for drinking.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"faq-question\"\u003e10. Can this pump handle sewage or dirty water?\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003eNo. This pump is intended for \u003cstrong\u003eclear water only\u003c\/strong\u003e. Do not use it for sewage, heavily contaminated water, flammable liquids, fuels, oils, or explosive liquids.\u003c\/p\u003e","brand":"U.S. Solid","offers":[{"title":"Default Title","offer_id":49097840427263,"sku":"JFWP00003","price":580.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/JFWP03_5.png?v=1788231325","url":"https:\/\/ussolid.com\/ms\/products\/1-hp-cast-iron-shallow-well-jet-pump-115-230v-26-gpm-max-flow","provider":"U.S. Solid","version":"1.0","type":"link"}