{"product_id":"rotational-viscometer-10-100-000-mpa-s-digital-lcd-4-speeds-auto-scan-data-output","title":"Rotational Viscometer, 10-100,000 mPa·s, Digital LCD, 4 Speeds, Auto Scan, Data Output","description":"\u003cstyle\u003e\n  .uss-detail {\n    color: #222;\n    font-family: Arial, sans-serif;\n    line-height: 1.6;\n  }\n\n  .uss-detail * {\n    box-sizing: border-box;\n  }\n\n  .uss-detail-section {\n    margin: 28px 0;\n  }\n\n  .uss-detail-title {\n    color: #111;\n    font-size: 22px;\n    font-weight: 700;\n    margin: 0 0 12px;\n    padding-bottom: 8px;\n  }\n\n  .uss-detail p,\n  .uss-detail li {\n    font-size: 16px;\n  }\n\n  .uss-detail p {\n    margin: 0 0 14px;\n  }\n\n  .uss-detail-list {\n    margin: 0;\n    padding-left: 22px;\n  }\n\n  .uss-detail-list li {\n    margin: 0 0 10px;\n  }\n\n  .uss-detail-list strong {\n    color: #111;\n  }\n\n  .uss-detail-image {\n    display: block;\n    height: auto;\n    margin: 16px auto 20px;\n    max-width: 100%;\n    width: 100%;\n  }\n\n  .uss-detail-feature-image {\n    max-width: 70%;\n  }\n\n  .uss-detail-packing {\n    display: flex;\n    flex-wrap: wrap;\n    gap: 20px;\n    margin: 15px 0;\n  }\n\n  .uss-detail-packing-list {\n    flex: 1 1 280px;\n  }\n\n  .uss-detail-packing-image {\n    flex: 1 1 280px;\n  }\n\n  .uss-detail-callout {\n    background: #f5f5f5;\n    border-left: 4px solid #5aa61a;\n    margin: 20px 0;\n    padding: 16px 18px;\n  }\n\n  .uss-detail-callout p:last-child {\n    margin-bottom: 0;\n  }\n\n  .uss-detail-table-wrap {\n    margin: 15px 0;\n    overflow-x: auto;\n    -webkit-overflow-scrolling: touch;\n  }\n\n  .uss-detail-table {\n    background: #fff;\n    border-collapse: collapse;\n    min-width: 620px;\n    width: 100%;\n  }\n\n  .uss-detail-table th,\n  .uss-detail-table td {\n    border-bottom: 1px solid #d8d8d8;\n    padding: 10px 12px;\n    text-align: left;\n    vertical-align: top;\n  }\n\n  .uss-detail-table th {\n    background: #f2f2f2;\n    color: #111;\n    font-size: 15px;\n    font-weight: 700;\n    width: 23%;\n  }\n\n  .uss-detail-table td {\n    color: #333;\n    font-size: 15px;\n    width: 27%;\n  }\n\n  .uss-detail-faq {\n    margin: 0 0 18px;\n  }\n\n  .uss-detail-faq-question {\n    color: #111;\n    font-size: 16px;\n    font-weight: 700;\n    margin: 0 0 5px;\n  }\n\n  .uss-detail-faq-answer {\n    color: #333;\n    font-size: 16px;\n    margin: 0;\n  }\n\n  @media only screen and (max-width: 768px) {\n    .uss-detail-title {\n      font-size: 20px;\n    }\n\n    .uss-detail p,\n    .uss-detail li,\n    .uss-detail-faq-question,\n    .uss-detail-faq-answer {\n      font-size: 15px;\n    }\n\n    .uss-detail-table th,\n    .uss-detail-table td {\n      font-size: 14px;\n      padding: 8px;\n    }\n\n    .uss-detail-feature-image {\n      max-width: 100%;\n    }\n  }\n\u003c\/style\u003e\n\u003cdiv class=\"uss-detail\"\u003e\n\u003cimg class=\"uss-detail-image\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFDVT\/DVT01-21\/DVT01-23-TITLE.png\" alt=\"U.S. Solid USS-DVT01023 Digital Rotational Viscometer\"\u003e\n\u003csection class=\"uss-detail-section\"\u003e\n\u003ch2 class=\"uss-detail-title\"\u003eINTRODUCTION\u003c\/h2\u003e\n\u003cp\u003eThe U.S. Solid Digital Rotational Viscometer measures the viscosity of compatible liquid samples for laboratory testing, production inspection, and routine quality control. Its large LCD screen provides direct readings of viscosity and testing information, while microcomputer control supports stable operation and practical method setup.\u003c\/p\u003e\n\u003cp\u003eWith four fixed speeds, standard No. 1 to No. 4 rotors, timed measurement, and automatic scanning assistance, the helps users select suitable test conditions for oils, paints, inks, adhesives, coatings, food products, and other compatible liquid or semi-liquid samples.\u003c\/p\u003e\n\u003cdiv class=\"uss-detail-callout\"\u003e\n\u003cp\u003e\u003cstrong\u003eImportant:\u003c\/strong\u003e Measurement results depend on the selected rotor, speed, sample temperature, and sample properties. For meaningful comparisons, use consistent test conditions and keep torque within the recommended operating range.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003csection class=\"uss-detail-section\"\u003e\n\u003ch2 class=\"uss-detail-title\"\u003eFEATURES\u003c\/h2\u003e\n\u003cimg class=\"uss-detail-image uss-detail-feature-image\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFDVT\/DVT01-21\/DVT23-feature.png\" alt=\"U.S. Solid USS-DVT01023 Digital Rotational Viscometer Features\"\u003e\n\u003cul class=\"uss-detail-list\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eLarge LCD Display:\u003c\/strong\u003e Displays viscosity, rotor, speed, and other test information directly for convenient monitoring during measurement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e4 Fixed Test Speeds:\u003c\/strong\u003e Select 6, 12, 30, or 60 rpm to establish suitable conditions for compatible liquid samples.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e1-100,000 mPa·s Range:\u003c\/strong\u003e Covers a broad viscosity range when used with the appropriate standard rotor and speed combination.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomatic Scanning Assistance:\u003c\/strong\u003e Automatically scans and recommends a suitable rotor and rotational-speed combination to support initial range selection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTimed Measurement:\u003c\/strong\u003e Standard timed-measurement function supports repeatable test procedures and observation of viscosity changes over time.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Range Display:\u003c\/strong\u003e Shows the maximum measurable viscosity for the selected rotor and speed combination.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eData Output Ready:\u003c\/strong\u003e Includes a data output interface. Optional data-processing software and compatible printing accessories are available separately.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/section\u003e\n\u003csection class=\"uss-detail-section\"\u003e\n\u003ch2 class=\"uss-detail-title\"\u003eAPPLICATIONS\u003c\/h2\u003e\n\u003cimg class=\"uss-detail-image\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFDVT\/Application.png\" alt=\"Digital rotational viscometer applications\"\u003e\n\u003cul class=\"uss-detail-list\"\u003e\n\u003cli\u003ePaints, coatings, inks, and paper pulp\u003c\/li\u003e\n\u003cli\u003eAdhesives, latex, solvents, and biochemical products\u003c\/li\u003e\n\u003cli\u003eCosmetics, creams, lotions, and personal-care formulations\u003c\/li\u003e\n\u003cli\u003eFood products, starches, sauces, and similar liquid or semi-liquid samples\u003c\/li\u003e\n\u003cli\u003eLaboratory research, production inspection, and quality-control testing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/section\u003e\n\u003csection class=\"uss-detail-section\"\u003e\n\u003ch2 class=\"uss-detail-title\"\u003ePACKAGE OVERVIEW\u003c\/h2\u003e\n\u003cdiv class=\"uss-detail-packing\"\u003e\n\u003cdiv class=\"uss-detail-packing-list\"\u003e\n\u003cp\u003ePackage contents and optional accessories may vary by the ordered configuration. Please review the product listing and order details for the included components.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"uss-detail-packing-image\"\u003e\u003cimg class=\"uss-detail-image\" src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFDVT\/4L-1-package.png\" alt=\"Digital rotational viscometer package overview\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003csection class=\"uss-detail-section\"\u003e\n\u003ch2 class=\"uss-detail-title\"\u003eSPECIFICATIONS\u003c\/h2\u003e\n\u003cdiv class=\"uss-detail-table-wrap\"\u003e\n\u003ctable class=\"uss-detail-table\" style=\"width: 99.9828%;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 23.0173%;\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"width: 26.9506%;\"\u003eUSS-DVT01023\u003c\/td\u003e\n\u003cth style=\"width: 23.0173%;\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"width: 26.9506%;\"\u003eU.S. Solid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 23.0173%;\"\u003eMeasuring Range\u003c\/th\u003e\n\u003ctd style=\"width: 26.9506%;\"\u003e1-100,000 mPa·s (cP)\u003c\/td\u003e\n\u003cth style=\"width: 23.0173%;\"\u003eDisplay\u003c\/th\u003e\n\u003ctd style=\"width: 26.9506%;\"\u003eLCD Display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 23.0173%;\"\u003eStandard Rotors\u003c\/th\u003e\n\u003ctd style=\"width: 26.9506%;\"\u003eNo. 1, No. 2, No. 3, No. 4\u003c\/td\u003e\n\u003cth style=\"width: 23.0173%;\"\u003eOptional Rotor\u003c\/th\u003e\n\u003ctd style=\"width: 26.9506%;\"\u003e\n\u003cstrong\u003eNo. 0 Rotor\u003c\/strong\u003e for Ultra-Low Viscosity Testing \u003cstrong\u003eBelow 10 mPa·s\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 23.0173%;\"\u003eRotating Speeds\u003c\/th\u003e\n\u003ctd style=\"width: 26.9506%;\"\u003e6 \/ 12 \/ 30 \/ 60 rpm\u003c\/td\u003e\n\u003cth style=\"width: 23.0173%;\"\u003eViscosity Resolution\u003c\/th\u003e\n\u003ctd style=\"width: 26.9506%;\"\u003e0.01 mPa·s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 23.0173%;\"\u003eMeasurement Error\u003c\/th\u003e\n\u003ctd style=\"width: 26.9506%;\"\u003e±2% of Full Scale for Newtonian Fluids\u003c\/td\u003e\n\u003cth style=\"width: 23.0173%;\"\u003eRepeatability Error\u003c\/th\u003e\n\u003ctd style=\"width: 26.9506%;\"\u003e±1% for Newtonian Fluids\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 23.0173%;\"\u003eTimed Measurement\u003c\/th\u003e\n\u003ctd style=\"width: 26.9506%;\"\u003eStandard\u003c\/td\u003e\n\u003cth style=\"width: 23.0173%;\"\u003eAutomatic Scanning\u003c\/th\u003e\n\u003ctd style=\"width: 26.9506%;\"\u003eAvailable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 23.0173%;\"\u003eTemperature Measurement\u003c\/th\u003e\n\u003ctd style=\"width: 26.9506%;\"\u003eAvailable with Compatible Temperature Probe Configuration\u003c\/td\u003e\n\u003cth style=\"width: 23.0173%;\"\u003eData Output Interface\u003c\/th\u003e\n\u003ctd style=\"width: 26.9506%;\"\u003eAvailable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 23.0173%;\"\u003ePower Supply\u003c\/th\u003e\n\u003ctd style=\"width: 26.9506%;\"\u003e110V \/ 60Hz or 220V \/ 50Hz\u003c\/td\u003e\n\u003cth style=\"width: 23.0173%;\"\u003eOverall Dimensions\u003c\/th\u003e\n\u003ctd style=\"width: 26.9506%;\"\u003e300 × 300 × 450 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003csection class=\"uss-detail-section\"\u003e\n\u003ch2 class=\"uss-detail-title\"\u003eFAQ\u003c\/h2\u003e\n\u003cdiv class=\"uss-detail-faq\"\u003e\n\u003cp class=\"uss-detail-faq-question\"\u003e1. How do I select the appropriate rotor and speed?\u003c\/p\u003e\n\u003cp class=\"uss-detail-faq-answer\"\u003eIf the sample viscosity is unknown, begin with a higher-numbered rotor at a low speed, such as the No. 4 rotor at 6 rpm. Adjust the rotor and speed according to the measured torque and the instrument's measurement range table. Higher-viscosity liquids generally require a higher-numbered rotor at a lower speed; lower-viscosity liquids generally require a lower-numbered rotor at a higher speed.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"uss-detail-faq\"\u003e\n\u003cp class=\"uss-detail-faq-question\"\u003e2. Does the USS-DVT01023 measure sample temperature?\u003c\/p\u003e\n\u003cp class=\"uss-detail-faq-answer\"\u003eA compatible temperature-measurement configuration is available. The temperature probe records sample temperature; it does not heat or cool the sample. Separate temperature-control equipment is required when heating or cooling is needed.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"uss-detail-faq\"\u003e\n\u003cp class=\"uss-detail-faq-question\"\u003e3. How can I help maintain measurement accuracy?\u003c\/p\u003e\n\u003cp class=\"uss-detail-faq-answer\"\u003eKeep the sample temperature stable, avoid air bubbles, keep the rotor centered in the sample, and use the same rotor, speed, container, and test duration when comparing samples. For Newtonian fluids, the specified measurement error is ±2% of full scale.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"uss-detail-faq\"\u003e\n\u003cp class=\"uss-detail-faq-question\"\u003e4. What is the optional No. 0 rotor used for?\u003c\/p\u003e\n\u003cp class=\"uss-detail-faq-answer\"\u003eThe optional No. 0 rotor is intended for compatible ultra-low-viscosity samples below 10 mPa·s. It is not included with the standard No. 1 to No. 4 rotor configuration unless specifically stated.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"uss-detail-faq\"\u003e\n\u003cp class=\"uss-detail-faq-question\"\u003e5. Can it connect to external accessories?\u003c\/p\u003e\n\u003cp class=\"uss-detail-faq-answer\"\u003eThe instrument includes a data output interface. Optional accessories may include data-processing software, temperature-control equipment, a temperature probe, and compatible printing equipment, depending on the ordered configuration.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e","brand":"U.S. Solid","offers":[{"title":"Default Title","offer_id":50974710399231,"sku":"JFDVT01023","price":659.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/4_814d71fc-59b6-4e6a-bda3-5c41b37e63f9.png?v=1786684877","url":"https:\/\/ussolid.com\/pl\/products\/rotational-viscometer-10-100-000-mpa-s-digital-lcd-4-speeds-auto-scan-data-output","provider":"U.S. Solid","version":"1.0","type":"link"}