{"product_id":"1-1-4-electric-actuated-ball-valve-heavy-duty-3-piece-industrial-ball-valve-304ss","title":"1 1\/4\" Electric Actuated Ball Valve, 110V AC Heavy Duty 3-Piece Industrial Ball Valve,304SS, ON\/OFF Type, Dry Contact","description":"\u003cdiv style=\"font-family: Arial, sans-serif; color: black;\" class=\"desktop-only\"\u003e\n\u003ch3 style=\"margin-bottom: 20px; margin-top: 0;\"\u003e\u003cimg alt=\"Product Introduction\" style=\"width: 100%; max-width: 100%; height: auto; display: block;\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/e448011edd64412b090515ded8262a19.jpg?v=1780117738\"\u003e\u003c\/h3\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top: 0px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; line-height: 26px; font-family: Arial; color: black; margin-bottom: 20px;\"\u003eThis premium flow control solution integrates a heavy-duty 3-piece stainless steel ball valve with a high-performance electric actuator. Engineered for reliability and precision, it provides a comprehensive hardware suite for automated systems, offering superior durability, seamless integration, and simplified maintenance in demanding industrial environments.\u003c\/p\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"margin-bottom: 20px; text-align: center;\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/ig_091236ea01646e01016a1fc6106344819babe6cfa61e9ff177.png?v=1780468642\"\u003e\u003c\/div\u003e\n\u003cul style=\"font-size: 16px; line-height: 26px; color: black; font-family: Arial; margin-bottom: 20px; padding-left: 20px;\"\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003ePremium Material Construction:\u003c\/strong\u003e Crafted from high-grade 304 stainless steel, the valve body is highly resistant to corrosion, making it suitable for handling weak acids, weak alkalis, chemical solvents, and water.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eMaintenance-Friendly 3-Piece Design:\u003c\/strong\u003e The innovative 3-piece body construction allows for seamless in-line maintenance. Internal components can be easily cleaned or replaced without the need to disconnect the pipes, significantly reducing downtime and service costs.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eHigh-Pressure \u0026amp; Full-Bore Efficiency:\u003c\/strong\u003e Designed for maximum performance, the full-bore configuration guarantees minimal pressure drop, ensuring optimal flow capacity even in high-pressure systems.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eSmart Automation Ready:\u003c\/strong\u003e Equipped with integrated limit switches and position feedback, the actuator allows for seamless integration with PLC systems, enabling precise remote control, real-time monitoring, and full automation in complex industrial processes.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eHigh-Torque Reliability:\u003c\/strong\u003e Powered by a compact yet robust heavy-duty motor, the actuator delivers a steady torque range of 50Nm to 100Nm, ensuring consistent full-port opening and reliable drop-tight sealing for every cycle.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eEnhanced Safety \u0026amp; Self-Locking:\u003c\/strong\u003e The actuator features an integrated self-locking mechanism to ensure valve stability and system integrity. Additionally, a built-in manual override port ensures safe, reliable intervention during power outages or emergencies.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eRugged Outdoor Durability:\u003c\/strong\u003e Engineered for the elements, the unit is encased in a powder-coated polyester aluminum housing, providing exceptional resistance to corrosion and harsh weather.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eAdvanced Circuitry Protection:\u003c\/strong\u003e To ensure long-term electrical reliability, the internal PCBA is treated with a protective sealant, effectively preventing damage from moisture, condensation, and short circuits.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px;\"\u003e\u003cimg alt=\"Applications\" style=\"width: 100%; max-width: 100%; height: auto; display: block;\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/Application_d83d7c67-93f0-46dd-bb8d-c1c7a38e6775.png?v=1779780603\"\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eWIRING DIAGRAMS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 15px; margin-bottom: 20px;\"\u003e\n\u003cimg alt=\"Wiring Diagram 1\" style=\"flex: 1; min-width: 280px; max-width: 100%; height: auto;\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/1_4a363947-fbb8-40f1-aeec-eb00c6867b4b.jpg?v=1780118579\"\u003e \u003cimg alt=\"Wiring Diagram 2\" style=\"flex: 1; min-width: 280px; max-width: 100%; height: auto;\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/2_13ae975c-b12f-4d7e-98d7-427307f10bc9.jpg?v=1780118579\"\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eELECTRIC WIRING\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 20px; margin-bottom: 20px;\"\u003e\n\u003cdiv style=\"flex: 1; min-width: 280px; text-align: center;\"\u003e\n\u003ch4 style=\"font-size: 16px; margin-top: 0; margin-bottom: 10px;\"\u003e\u003cstrong\u003e[OPEN]\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cimg style=\"width: 100%; max-width: 450px; height: auto;\" alt=\"OPEN\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/JFHDBV-gif1.gif?v=1780298419\"\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; min-width: 280px; text-align: center;\"\u003e\n\u003ch4 style=\"font-size: 16px; margin-top: 0; margin-bottom: 10px;\"\u003e\u003cstrong\u003e[CLOSED]\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cimg style=\"width: 100%; max-width: 450px; height: auto;\" alt=\"CLOSED\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/JFHDBV-gif2.gif?v=1780298416\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"width: 100%; overflow-x: auto; margin-bottom: 20px;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; background-color: #ffffff; font-size: 16px; font-family: Arial; color: black;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"border-bottom: 1px dashed #000000;\"\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; text-align: center;\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003eUSS-HDBV00014\u003c\/td\u003e\n\u003cth style=\"width: 20%; padding: 10px; background-color: rgb(240, 240, 240); font-weight: bold; text-align: center;\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"width: 30%; text-align: left; padding: 10px;\"\u003eU.S. Solid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed #000000;\"\u003e\n\u003cth style=\"padding: 10px; background-color: #f0f0f0; font-weight: bold;\"\u003eSize\u003c\/th\u003e\n\u003ctd style=\"padding: 10px;\"\u003e1 1\/4\"\u003c\/td\u003e\n\u003cth style=\"padding: 10px; background-color: #f0f0f0; font-weight: bold;\"\u003eWiring Type\u003c\/th\u003e\n\u003ctd style=\"padding: 10px;\"\u003eType B: ON\/OFF Type, Dry Contact\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed #000000;\"\u003e\n\u003cth style=\"padding: 10px; background-color: #f0f0f0; font-weight: bold;\"\u003eValve Material\u003c\/th\u003e\n\u003ctd style=\"padding: 10px;\"\u003e304SS\u003c\/td\u003e\n\u003cth style=\"padding: 10px; background-color: #f0f0f0; font-weight: bold;\"\u003eBall Seal\u003c\/th\u003e\n\u003ctd style=\"padding: 10px;\"\u003ePTFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed #000000;\"\u003e\n\u003cth style=\"padding: 10px; background-color: #f0f0f0; font-weight: bold;\"\u003eOperating Time\u003c\/th\u003e\n\u003ctd style=\"padding: 10px;\"\u003e20 Seconds\u003c\/td\u003e\n\u003cth style=\"padding: 10px; background-color: #f0f0f0; font-weight: bold;\"\u003eWorking Voltage\u003c\/th\u003e\n\u003ctd style=\"padding: 10px;\"\u003e110V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed #000000;\"\u003e\n\u003cth style=\"padding: 10px; background-color: #f0f0f0; font-weight: bold;\"\u003eMax Power\u003c\/th\u003e\n\u003ctd style=\"padding: 10px;\"\u003e20 W\u003c\/td\u003e\n\u003cth style=\"padding: 10px; background-color: #f0f0f0; font-weight: bold;\"\u003eMax Torque\u003c\/th\u003e\n\u003ctd style=\"padding: 10px;\"\u003e50 N m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed #000000;\"\u003e\n\u003cth style=\"padding: 10px; background-color: #f0f0f0; font-weight: bold;\"\u003eMax Medium Pressure\u003c\/th\u003e\n\u003ctd style=\"padding: 10px;\"\u003e1.6 Mpa\u003c\/td\u003e\n\u003cth style=\"padding: 10px; background-color: #f0f0f0; font-weight: bold;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n\u003ctd style=\"padding: 10px;\"\u003e-30°C to 180°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed #000000;\"\u003e\n\u003cth style=\"padding: 10px; background-color: #f0f0f0; font-weight: bold;\"\u003eLife Expectancy\u003c\/th\u003e\n\u003ctd style=\"padding: 10px;\"\u003e30,000 to 50,000 Cycles\u003c\/td\u003e\n\u003cth style=\"padding: 10px; background-color: #f0f0f0; font-weight: bold;\"\u003eBore Type\u003c\/th\u003e\n\u003ctd style=\"padding: 10px;\"\u003eFull port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed #000000;\"\u003e\n\u003cth style=\"padding: 10px; background-color: #f0f0f0; font-weight: bold;\"\u003eThread Type\u003c\/th\u003e\n\u003ctd style=\"padding: 10px;\"\u003eNPT\u003c\/td\u003e\n\u003cth style=\"padding: 10px; background-color: #f0f0f0; font-weight: bold;\"\u003eOperating State\u003c\/th\u003e\n\u003ctd style=\"padding: 10px;\"\u003eRemain in position\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px dashed #000000;\"\u003e\n\u003cth style=\"padding: 10px; background-color: #f0f0f0; font-weight: bold;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n\u003ctd style=\"padding: 10px;\"\u003e-30°C to 60°C\u003c\/td\u003e\n\u003cth style=\"padding: 10px; background-color: #f0f0f0; font-weight: bold;\"\u003eEnclosure Rating\u003c\/th\u003e\n\u003ctd style=\"padding: 10px;\"\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eWARNINGS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"font-size: 16px; line-height: 26px; color: black; font-family: Arial; margin-bottom: 20px; padding-left: 20px;\"\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003ePower Failure Behavior:\u003c\/strong\u003e This valve remains in its current position during a power outage. It does not automatically return to a preset position.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eVoltage Match Required:\u003c\/strong\u003e Supply voltage must match the actuator rating exactly. Incorrect voltage may permanently damage the unit.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eDedicated Power Circuit:\u003c\/strong\u003e Each actuator requires its own fuse-protected power supply. Do not connect multiple actuators in parallel.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eDisconnect Power Before Service:\u003c\/strong\u003e Always disconnect power before wiring, maintenance, or using the manual override.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eIP65 Weather Resistant:\u003c\/strong\u003e Suitable for outdoor use, but additional protection is recommended for permanent outdoor installations.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eLow Power Consumption:\u003c\/strong\u003e Power is only used during opening and closing. No power is consumed when fully open or fully closed.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eProfessional Installation Recommended:\u003c\/strong\u003e Installation should be performed by qualified personnel familiar with electrical control systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top: 20px; margin-bottom: 10px; color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"font-size: 16px; line-height: 26px; font-family: Arial; color: black; margin-bottom: 20px;\"\u003e\n\u003cp style=\"margin-bottom: 10px;\"\u003e\u003cstrong\u003e1: Can I manually operate the valve?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px; padding-left: 15px;\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes. The actuator features a manual override. We recommend manually cycling the valve before installation to verify smooth operation, and using the adjustment screws during commissioning to fine-tune open\/close positions.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 10px;\"\u003e\u003cstrong\u003e2: Can this valve be installed outdoors?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px; padding-left: 15px;\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes, depending on your model's IP rating. While our heavy-duty actuators are weather-resistant, we highly recommend using a protective cover or shelter for permanent outdoor installations to shield the unit from direct UV rays and ice buildup.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 10px;\"\u003e\u003cstrong\u003e3: Is this valve suitable for high-viscosity fluids or particulates?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px; padding-left: 15px;\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes, but with torque considerations. Our heavy-duty series is built for high-torque applications. However, extremely viscous mediums or large particulates will increase resistance. Ensure the operating torque remains within the actuator's rated capacity to avoid stalling.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 10px;\"\u003e\u003cstrong\u003e4: Is it normal for the actuator to feel hot during operation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px; padding-left: 15px;\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes, it is normal to feel warm during continuous cycling. The actuator includes built-in power-limiting features to prevent overheating under normal use. If the housing becomes too hot to touch, please check that you are not exceeding the recommended duty cycle or the ambient temperature limit (-30°C to +60°C).\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 10px;\"\u003e\u003cstrong\u003e5: Can I wire multiple actuators in parallel on the same circuit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 20px; padding-left: 15px;\"\u003e\u003cstrong\u003eA:\u003c\/strong\u003e No. Each motorized actuator must be installed on its own dedicated, fuse-protected circuit to ensure proper signal response and prevent electrical interference or damage.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 16px; margin-top: 25px;\"\u003eDownload user manual \u003ca style=\"color: #0066cc; text-decoration: underline;\" rel=\"noopener\" href=\"http:\/\/file.ussolid.com\/content\/JFHDBV\/JFHDBV-%20Electric%20Actuated%20Ball%20Valve%20instruction%20manual.pdf\" target=\"_blank\"\u003ehere\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"U.S. Solid","offers":[{"title":"Default Title","offer_id":48293065818367,"sku":"JFHDBV00014","price":349.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/1_82ed4319-d78a-4cd0-98eb-202e06a44788.jpg?v=1778312794","url":"https:\/\/ussolid.com\/products\/1-1-4-electric-actuated-ball-valve-heavy-duty-3-piece-industrial-ball-valve-304ss","provider":"U.S. Solid","version":"1.0","type":"link"}