{"product_id":"1-1-4-zinc-alloy-solenoid-valve-24v-dc-nbr-seal-normally-closed","title":"1-1\/4\" Zinc-Alloy Solenoid Valve - 24V DC , NBR Seal, Normally Closed","description":"\u003cbody\u003e \n\n\n    \u003cstyle\u003e\n        @media only screen and (max-width: 600px) {\n        }\n    \u003c\/style\u003e\n\n\n    \u003cdiv class=\"desktop-only\"\u003e\n       \n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFZSV\/coverimage.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; line-height: 26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 10px; color: black; font-family: Arial;\"\u003eThe U.S. Solid USS-ZSV Series Zinc-alloy Solenoid Valves are engineered with both performance and cost-effectiveness in mind.  These valves utilize a zinc alloy valve body, a material selected for its ability to withstand significant pressure while offering a more economical solution than brass or stainless steel.  This series is designed to be a reliable and affordable option for various applications, making it a valuable addition to your toolkit.\u003c\/p\u003e\n        \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFZSV\/features-01.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFNSV\/Application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cdiv style=\"width: 100%; overflow-x: auto;margin-top:20px;\"\u003e\n    \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"width: 50%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFZSV\/POLARITY.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n            \u003c\/td\u003e\n            \u003ctd valign=\"top\" style=\"width: 100%;text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e\n                \u003cp style=\"margin-top: 50px;margin-bottom: 0px;\"\u003e\u003cspan style=\"font-size: 22px;color:black; font-weight: bold;\"\u003ePOLARITY\u003c\/span\u003e\u003c\/p\u003e\n                \u003cp style=\"line-height: 2;margin-top:30px;\"\u003eWhen dealing with valves equipped with two wires, an important characteristic to note is their polarity - insensitive design. This means that the valve will actuate correctly regardless of which terminal each wire is connected to. Whether a wire is attached to the positive (+) or negative (-) terminal makes no difference in the valve’s operation. However, it’s essential to be aware that some valve units incorporate an additional ground wire.To determine if your valve has a ground wire, you’ll need to open up the connector.For valves with a ground wire, proper grounding is crucial. \u003c\/p\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/table\u003e\n\u003c\/div\u003e\n          \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e \n \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-ZSV00035\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eU.S. Solid\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1-1\/4\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eFlow Aperture\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e35 mm\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eZinc Alloy\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eGasket \/ Diaphragm \/ Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNBR\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eRated Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eDC 24V\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperational pressure range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eAir\/Water: 0-8 Bar (0 to 116 PSI); Oil: 0-5 Bar(0 to 72 PSI)\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003ePower Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e40 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperation Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eDirect Lift Valve\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSuitable Media\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eWater, oil, Diesel fuel, kerosene etc.\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eFlow Value\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e24 Cv\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature, Minimum\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e14 degrees Fahrenheit (-10 degrees Celsius)\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Maximum\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e176 degrees Fahrenheit (80 degrees Celsius)\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\/G\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNormally Closed\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n      \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/CE\/CE-EMC.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n            \u003cdiv style=\"width: 100%; overflow-x: auto;margin-top:20px;\"\u003e\n    \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n        \u003ctr\u003e\n            \u003ctd valign=\"top\" style=\"width: 100%;text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e\n                \u003cp style=\"margin-top: 0px;color:black;margin-bottom: 0px;\"\u003e\u003cspan style=\"font-size: 22px; font-weight: bold;\"\u003eOVER HEATING\u003c\/span\u003e\u003c\/p\u003e\n                \u003cp style=\"line-height: 2;margin-top:20px;\"\u003e Not designed for continuous operation(not a 100% duty cycle). While energized, under normal operating conditions, solenoid valve will get HOT. The coil will reach a maximum temperature of about 176°F (80°C), which is fully complied with national standard: JB\/T7352-2010. If energized continuously for more than 8 hours the coil may burn.\u003c\/p\u003e\n            \u003c\/td\u003e\n            \u003ctd style=\"width: 60%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFZSV\/overheating.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/table\u003e\n\u003c\/div\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. Can it be used outdoors? \u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eSolenoid valves can withstand water spray. However, if they are to be permanently installed outdoors, it’s advisable to house them in a protective enclosure. This helps safeguard the valves and ensures their long - term durability.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2. Can these solenoid valves be used continuously for extended periods?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThese valves should be energized for less than 8 hours. While most do not exceed 18W of power, the coils are in a contained area and can burn out if energized for too long. We recommend using a computer fan to keep the coil cool if continuous operation is necessary.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.How long should you wait between two consecutive five-hour uses of our solenoid valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIt is recommended to allow about 20 minutes of cooling time between two consecutive 5-hour operating sessions. The exact cooling time may vary depending on ambient temperature and operating conditions.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes. This valve is crafted from zinc alloy. Zinc alloy is free of lead, making it suitable for use in drinking water systems.\u003c\/p\u003e\n    \u003c\/div\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:20px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual \u003ca href=\"http:\/\/file.ussolid.com\/content\/JFSV\/Manual-%20U.S.%20Solid%20Solenoid%20Valves.pdf\" target=\"_blank\"\u003ehere\u003c\/a\u003e.\u003c\/p\u003e\n    \u003c\/div\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"mobile-only\"\u003e\n      \n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFZSV\/coverimage.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; line-height:26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 0px; color: black; font-family: Arial;\"\u003eThe U.S. Solid USS-ZSV Series Zinc-alloy Solenoid Valves are engineered with both performance and cost-effectiveness in mind.  These valves utilize a zinc alloy valve body, a material selected for its ability to withstand significant pressure while offering a more economical solution than brass or stainless steel.  This series is designed to be a reliable and affordable option for various applications, making it a valuable addition to your toolkit.\u003c\/p\u003e\n            \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFZSV\/features-01-APP.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-bottom:10px; margin-top:20px; color: black;\"\u003e\u003cstrong\u003eAPPLICATION\u003c\/strong\u003e\u003c\/p\u003e\n                 \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFNSV\/Application-APP.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003c\/div\u003e\n   \u003cp style=\"font-size: 22px; text-align: left; margin-bottom:10px; margin-top:20px; color: black;\"\u003e\u003cstrong\u003ePOLARITY\u003c\/strong\u003e\u003c\/p\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eWhen dealing with valves equipped with two wires, an important characteristic to note is their polarity - insensitive design. This means that the valve will actuate correctly regardless of which terminal each wire is connected to. Whether a wire is attached to the positive (+) or negative (-) terminal makes no difference in the valve’s operation. However, it’s essential to be aware that some valve units incorporate an additional ground wire.To determine if your valve has a ground wire, you’ll need to open up the connector.For valves with a ground wire, proper grounding is crucial. \u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFZSV\/POLARITY.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n      \u003cp style=\"font-size: 16px; text-align: left; margin-bottom:10px; margin-top:20px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n           \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-ZSV00035\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eU.S. Solid\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1-1\/4\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eFlow Aperture\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e35 mm\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eZinc Alloy\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eGasket \/ Diaphragm \/ Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNBR\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eRated Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eDC 24V\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperational pressure range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eAir\/Water: 0-8 Bar (0 to 116 PSI); Oil: 0-5 Bar(0 to 72 PSI)\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003ePower Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e40 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperation Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eDirect Lift Valve\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSuitable Media\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eWater, oil, Diesel fuel, kerosene etc.\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eFlow Value\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e24 Cv\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature, Minimum\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e14 degrees Fahrenheit (-10 degrees Celsius)\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Maximum\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e176 degrees Fahrenheit (80 degrees Celsius)\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\/G\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNormally Closed\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n      \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/CE\/CE-EMC.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n           \u003cp style=\"font-size: 22px; text-align: left; margin-bottom:10px; margin-top:20px; color: black;\"\u003e\u003cstrong\u003eOVER HEATING\u003c\/strong\u003e\u003c\/p\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e Not designed for continuous operation(not a 100% duty cycle). While energized, under normal operating conditions, solenoid valve will get HOT. The coil will reach a maximum temperature of about 176°F (80°C), which is fully complied with national standard: JB\/T7352-2010. If energized continuously for more than 8 hours the coil may burn.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFZSV\/overheating.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n       \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. Can it be used outdoors? \u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eSolenoid valves can withstand water spray. However, if they are to be permanently installed outdoors, it’s advisable to house them in a protective enclosure. This helps safeguard the valves and ensures their long - term durability.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2. Can these solenoid valves be used continuously for extended periods?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThese valves should be energized for less than 8 hours. While most do not exceed 18W of power, the coils are in a contained area and can burn out if energized for too long. We recommend using a computer fan to keep the coil cool if continuous operation is necessary.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.How long should you wait between two consecutive five-hour uses of our solenoid valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIt is recommended to allow about 20 minutes of cooling time between two consecutive 5-hour operating sessions. The exact cooling time may vary depending on ambient temperature and operating conditions.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes. This valve is crafted from zinc alloy. Zinc alloy is free of lead, making it suitable for use in drinking water systems.\u003c\/p\u003e\n    \u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual \u003ca href=\"http:\/\/file.ussolid.com\/content\/JFSV\/Manual-%20U.S.%20Solid%20Solenoid%20Valves.pdf\" target=\"_blank\"\u003ehere\u003c\/a\u003e.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n    \u003cscript\u003e\n      \n        const isMobile = window.matchMedia(\"only screen and (max-width: 600px)\").matches;\n        const desktopContent = document.querySelector('.desktop-only');\n        const mobileContent = document.querySelector('.mobile-only');\n\n        if (isMobile) {\n           \n            console.log('');\n           \n            desktopContent.style.display = 'none';\n            mobileContent.style.display = 'block';\n        } else {\n            \n            console.log('');            \n            \n            desktopContent.style.display = 'block';\n            mobileContent.style.display = 'none';\n        }\n    \u003c\/script\u003e\n\n\n\n\u003c\/body\u003e","brand":"U.S. Solid","offers":[{"title":"NPT","offer_id":47934552703231,"sku":"JFZSV00035","price":72.9,"currency_code":"USD","in_stock":true},{"title":"G","offer_id":47934552735999,"sku":"JFZSV00135","price":57.9,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/1_beb88f67-1cdc-4305-a53d-49bc84502edc.jpg?v=1766469566","url":"https:\/\/ussolid.com\/products\/1-1-4-zinc-alloy-solenoid-valve-24v-dc-nbr-seal-normally-closed","provider":"U.S. Solid","version":"1.0","type":"link"}