{"product_id":"1-brass-solenoid-valve-24v-ac-normally-closed-4-4-232-psi-viton-seal","title":"1\" Brass  Solenoid Valve - 24V AC, Normally Closed, 4.4-232 PSI, VITON Seal","description":"\u003cbody\u003e \n\n\n    \u003cstyle\u003e\n        @media only screen and (max-width: 600px) {\n        }\n    \u003c\/style\u003e\n\n\n    \u003cdiv class=\"desktop-only\"\u003e\n       \n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFYSV\/coverimage-pilot-operated.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; line-height: 26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 10px; color: black; font-family: Arial;\"\u003eThe U.S. Solid USS-YSV Series offers 2-way electric solenoid valves with both normally closed and normally open models, featuring semi-direct-acting functionality. These valves are available in 220\/24 VAC and 24\/12 VDC voltages and are constructed with industrial-grade brass or 304 stainless steel bodies and viton seal materials. Featuring a high-quality coil, this solenoid valve efficiently controls the opening and closing of the diaphragm in under 1 second for precise flow control. Suitable for various media types such as air, water, oil, natural gas, gasoline, diesel fuel, kerosene, and low viscosity fluids (less than 20 centistokes), this valve is designed for reliable performance.\u003c\/p\u003e\n        \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFYSV\/features-06-pilot-operated.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFNSV\/Application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cdiv style=\"width: 100%; overflow-x: auto;margin-top:20px;\"\u003e\n    \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"width: 50%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFNSV\/POLARITY.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n            \u003c\/td\u003e\n            \u003ctd valign=\"top\" style=\"width: 100%;text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e\n                \u003cp style=\"margin-top: 50px;margin-bottom: 0px;\"\u003e\u003cspan style=\"font-size: 22px; font-weight: bold;\"\u003ePOLARITY\u003c\/span\u003e\u003c\/p\u003e\n                \u003cp style=\"line-height: 2;margin-top:30px;\"\u003eWhen dealing with valves equipped with two wires, an important characteristic to note is their polarity - insensitive design. This means that the valve will actuate correctly regardless of which terminal each wire is connected to. Whether a wire is attached to the positive (+) or negative (-) terminal makes no difference in the valve’s operation. However, it’s essential to be aware that some valve units incorporate an additional ground wire.To determine if your valve has a ground wire, you’ll need to open up the connector.For valves with a ground wire, proper grounding is crucial. \u003c\/p\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/table\u003e\n\u003c\/div\u003e\n          \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e \n \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-YSV00115\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eU.S. Solid\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eFlow Aperture\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e25 mm\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eBrass\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eGasket \/ Diaphragm \/ Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eVITON\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eRated Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eAC 24V ± 10%\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eCurrent\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e0.92 A\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003ePower Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e22 VA\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperation Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003ePilot\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLevel of protection\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eIP65\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eFlow Value\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e12 Cv\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperational Pressure Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e4.4 - 232 PSI(0.3-16 bar)\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Temperature\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e-22°F ~ 302°F\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\/G\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNormally Closed\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/CE\/CE-EMC.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP65. The first digit 6 indicates complete dust - tightness. The second digit 5 means protection against water jets from any direction. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFNSV\/JFNSV-IP65.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP65 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2. Can these solenoid valves be used continuously for extended periods?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThese valves should be energized for less than 8 hours. While most do not exceed 18W of power, the coils are in a contained area and can burn out if energized for too long. We recommend using a computer fan to keep the coil cool if continuous operation is necessary.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.How long should you wait between two consecutive five-hour uses of our solenoid valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIt is recommended to allow about 20 minutes of cooling time between two consecutive 5-hour operating sessions. The exact cooling time may vary depending on ambient temperature and operating conditions.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNO. This valve is made of brass, which contains lead, should not be used for drinking water.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.Can it be used outdoors?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eWhile the solenoid valves have an IP65 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n    \u003c\/div\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:20px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual \u003ca href=\"http:\/\/file.ussolid.com\/content\/JFYSV\/Instruction%20Manual-JFYSV.pdf\" target=\"_blank\"\u003ehere\u003c\/a\u003e.\u003c\/p\u003e\n    \u003c\/div\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"mobile-only\"\u003e\n      \n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFYSV\/coverimage-pilot-operated.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; line-height:26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 0px; color: black; font-family: Arial;\"\u003eThe U.S. Solid USS-YSV Series offers 2-way electric solenoid valves with both normally closed and normally open models, featuring semi-direct-acting functionality. These valves are available in 220\/24 VAC and 24\/12 VDC voltages and are constructed with industrial-grade brass or 304 stainless steel bodies and viton seal materials. Featuring a high-quality coil, this solenoid valve efficiently controls the opening and closing of the diaphragm in under 1 second for precise flow control. Suitable for various media types such as air, water, oil, natural gas, gasoline, diesel fuel, kerosene, and low viscosity fluids (less than 20 centistokes), this valve is designed for reliable performance.\u003c\/p\u003e\n            \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFYSV\/features-06-pilot-operated-APP.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-bottom:10px; margin-top:20px; color: black;\"\u003e\u003cstrong\u003eAPPLICATION\u003c\/strong\u003e\u003c\/p\u003e\n                 \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFNSV\/Application-APP.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003c\/div\u003e\n   \u003cp style=\"font-size: 22px; text-align: left; margin-bottom:10px; margin-top:20px; color: black;\"\u003e\u003cstrong\u003ePOLARITY\u003c\/strong\u003e\u003c\/p\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eWhen dealing with valves equipped with two wires, an important characteristic to note is their polarity - insensitive design. This means that the valve will actuate correctly regardless of which terminal each wire is connected to. Whether a wire is attached to the positive (+) or negative (-) terminal makes no difference in the valve’s operation. However, it’s essential to be aware that some valve units incorporate an additional ground wire.To determine if your valve has a ground wire, you’ll need to open up the connector.For valves with a ground wire, proper grounding is crucial. \u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFNSV\/POLARITY.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n      \u003cp style=\"font-size: 16px; text-align: left; margin-bottom:10px; margin-top:20px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n          \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14PX; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14PX; border: 0px; background-color: #FFFFFF;\"\u003eUSS-YSV00115\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14PX; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14PX; border: 0px; background-color: #FFFFFF;\"\u003eU.S. Solid\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14PX; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14PX; border: 0px; background-color: #FFFFFF;\"\u003e1\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14PX; border: 0px; background-color: #f0f0f0; color: black;\"\u003eFlow Aperture\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14PX; border: 0px; background-color: #FFFFFF;\"\u003e25 mm\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14PX; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14PX; border: 0px; background-color: #FFFFFF;\"\u003eBrass\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14PX; border: 0px; background-color: #f0f0f0; color: black;\"\u003eGasket \/ Diaphragm \/ Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14PX; border: 0px; background-color: #FFFFFF;\"\u003eVITON\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14PX; border: 0px; background-color: #f0f0f0; color: black;\"\u003eRated Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14PX; border: 0px; background-color: #FFFFFF;\"\u003eAC 24V ± 10%\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14PX; border: 0px; background-color: #f0f0f0; color: black;\"\u003eCurrent\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14PX; border: 0px; background-color: #FFFFFF;\"\u003e0.92 A\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14PX; border: 0px; background-color: #f0f0f0; color: black;\"\u003ePower Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14PX; border: 0px; background-color: #FFFFFF;\"\u003e22 VA\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14PX; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperation Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14PX; border: 0px; background-color: #FFFFFF;\"\u003ePilot\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14PX; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLevel of protection\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14PX; border: 0px; background-color: #FFFFFF;\"\u003eIP65\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14PX; border: 0px; background-color: #f0f0f0; color: black;\"\u003eFlow Value\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14PX; border: 0px; background-color: #FFFFFF;\"\u003e12 Cv\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14PX; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperational Pressure Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14PX; border: 0px; background-color: #FFFFFF;\"\u003e4.4 - 232 PSI(0.3-16 bar)\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14PX; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Temperature\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14PX; border: 0px; background-color: #FFFFFF;\"\u003e-22°F ~ 302°F\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14PX; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14PX; border: 0px; background-color: #FFFFFF;\"\u003eNPT\/G\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14PX; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14PX; border: 0px; background-color: #FFFFFF;\"\u003eNormally Closed\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/CE\/CE-EMC.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP65. The first digit 6 indicates complete dust - tightness. The second digit 5 means protection against water jets from any direction. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFNSV\/JFNSV-IP65.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n       \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP65 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2. Can these solenoid valves be used continuously for extended periods?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThese valves should be energized for less than 8 hours. While most do not exceed 18W of power, the coils are in a contained area and can burn out if energized for too long. We recommend using a computer fan to keep the coil cool if continuous operation is necessary.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.How long should you wait between two consecutive five-hour uses of our solenoid valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIt is recommended to allow about 20 minutes of cooling time between two consecutive 5-hour operating sessions. The exact cooling time may vary depending on ambient temperature and operating conditions.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNO. This valve is made of brass, which contains lead, should not be used for drinking water.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.Can it be used outdoors?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eWhile the solenoid valves have an IP65 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n    \u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual \u003ca href=\"http:\/\/file.ussolid.com\/content\/JFYSV\/Instruction%20Manual-JFYSV.pdf\" target=\"_blank\"\u003ehere\u003c\/a\u003e.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n    \u003cscript\u003e\n      \n        const isMobile = window.matchMedia(\"only screen and (max-width: 600px)\").matches;\n        const desktopContent = document.querySelector('.desktop-only');\n        const mobileContent = document.querySelector('.mobile-only');\n\n        if (isMobile) {\n           \n            console.log('');\n           \n            desktopContent.style.display = 'none';\n            mobileContent.style.display = 'block';\n        } else {\n            \n            console.log('');            \n            \n            desktopContent.style.display = 'block';\n            mobileContent.style.display = 'none';\n        }\n    \u003c\/script\u003e\n\n\n\n\u003c\/body\u003e","brand":"U.S. Solid","offers":[{"title":"NPT","offer_id":47358419534079,"sku":"JFYSV00115","price":66.69,"currency_code":"USD","in_stock":true},{"title":"G","offer_id":47358419566847,"sku":"JFYSV00115-G","price":46.49,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/1_5c2feba3-6c9d-44a2-9bbb-a763c99bf5c9.jpg?v=1773382357","url":"https:\/\/ussolid.com\/products\/1-brass-solenoid-valve-24v-ac-normally-closed-4-4-232-psi-viton-seal","provider":"U.S. Solid","version":"1.0","type":"link"}