{"product_id":"continuous-flow-dual-channel-laboratory-syringe-pump","title":"Continuous-Flow Dual-Channel Laboratory Syringe Pump","description":"\u003cstyle\u003e     .options-section {\n    margin: 30px 0 20px;\n    font-family: Arial;\n}\n\n.options-card {\n    padding: 25px 30px;\n    border: 1px solid #f0f0f0;\n    background-color: #fafafa;\n    text-align: center;\n    border-radius: 8px;\n}\n\n.options-title {\n    font-size: 20px;\n    margin-bottom: 10px;\n    color: #333;\n    font-weight: bold;\n}\n\n.options-description {\n    font-size: 15px;\n    color: #666;\n    margin-bottom: 20px;\n    line-height: 1.5;\n}\n\n.options-btn {\n    display: inline-block;\n    padding: 15px 40px;\n    background-color: #2aa79b !important; \n    color: #FFFFFF !important;\n    text-decoration: none !important;\n    border-radius: 50px !important;\n    font-weight: bold !important;\n    box-shadow: 0 4px 6px rgba(0,0,0,0.1) !important;\n    transition: all 0.3s ease !important;\n    border: none !important;\n    cursor: pointer !important;\n    font-size: 16px !important;\n    letter-spacing: 0.5px !important;\n}\n\n.options-btn:hover {\n    background-color: #239087 !important;  \n    color: #FFFFFF !important;\n    transform: translateY(-2px) !important;\n    box-shadow: 0 6px 12px rgba(0,0,0,0.15) !important;\n}\n\n.options-btn:active {\n    background-color: #1e7f77 !important;  \n    color: #FFFFFF !important;\n    transform: translateY(0) !important;\n    box-shadow: 0 2px 4px rgba(0,0,0,0.1) !important;\n}\n    .faq-question {\n    background-color: #f2f2f2;\n    padding: 6px 8px;\n    margin: 15px 0 5px;\n    font-size: 16px;\n    line-height: 20px;\n    font-weight: bold;\n    font-family: Arial;\n    color: #000;\n}\n  .section-title {\n    font-size: 22px;\n    line-height: 22px;\n    font-weight: bold;\n    margin: 15px 0 5px;\n    font-family: Arial;\n    color: #000;\n  }\n\n  .section-title3 {\n    font-size: 22px;\n    line-height: 22px;\n    font-weight: bold;\n    margin: 15px 0 10px;\n    font-family: Arial;\n    color: #000;\n  }\n\n  .section-title4 {\n    font-size: 22px;\n    line-height: 22px;\n    font-weight: bold;\n    margin: 15px 0 10px;\n    font-family: Arial;\n    color: #000;\n  }\n\n  .section-description {\n    font-size: 16px;\n    line-height: 26px;\n    margin-bottom: 5px;\n    margin-top: 0;\n    color: black;\n    font-family: Arial;\n  }\n\n  .section-description2 {\n    font-size: 16px;\n    line-height: 26px;\n    margin: 0;\n    font-family: Arial;\n    color: black;\n    padding-left: 22px;\n  }\n\n  .parameters-table-wrapper {\n    overflow-x: auto;\n    -webkit-overflow-scrolling: touch;\n    margin-top: 0;\n  }\n\n  .parameters-table {\n    width: 100%;\n    min-width: 600px;\n    border-collapse: collapse;\n    margin-top: 0;\n    background-color: #fff;\n    font-family: Arial;\n  }\n\n  .parameters-table th,\n  .parameters-table td {\n    border-top: 1.2px solid #a6a6a6;\n    border-bottom: 1.2px solid #a6a6a6;\n    border-left: none;\n    border-right: none;\n    padding: 6px 5px;\n    text-align: left;\n    font-size: 16px;\n    line-height: 20px;\n    color: #000;\n  }\n\n  .parameters-table th {\n    background-color: #f2f2f2;\n    color: #2c2c2c;\n    font-weight: bold;\n  }\n\n  .mobile-scroll-note {\n    font-family: Arial;\n    font-size: 13px;\n    color: #666;\n    margin-bottom: 8px;\n    margin-top: 0;\n  }\n\n  @media (max-width: 768px) {\n    .parameters-table th,\n    .parameters-table td {\n      font-size: 14px;\n      padding: 8px 4px;\n    }\n  }\n\n  @media (max-width: 480px) {\n    .parameters-table th,\n    .parameters-table td {\n      font-size: 12px;\n      padding: 6px 3px;\n    }\n  }\n\u003c\/style\u003e\n\u003ch2 class=\"section-title\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/1-9.jpg?v=1782368522\" alt=\"\"\u003e\n\u003c\/h2\u003e\n\u003ch2 class=\"section-title\"\u003eIntroduction\u003c\/h2\u003e\n\u003cp class=\"section-description\"\u003eDeliver continuous, low-pulsation liquid flow for long-duration laboratory experiments.\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\u003cspan\u003eUnlike conventional syringe pumps that must stop for refilling, the U.S.Solid Continuous-Flow Dual-Channel Laboratory Syringe Pump alternates two synchronized syringe channels. While one syringe dispenses liquid, the other simultaneously refills. When paired with external check valves and T-valves, the system provides smooth and continuous fluid delivery with minimal interruption.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\u003cspan\u003eCompatible with 10 μL to 20 mL syringes, the system delivers flow rates from 0.001 μL\/min to 36.859 mL\/min, making it suitable for microfluidics, analytical chemistry, electrospinning, long-duration dosing, and other precision laboratory applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 class=\"section-title\"\u003eApplications\u003c\/h2\u003e\n\u003cstyle\u003e\n  .app-grid {\n    display: grid;\n    grid-template-columns: repeat(4, 1fr);\n    gap: 16px;\n    margin: 30px 0 20px;\n    font-family: 'Helvetica Neue', Arial, sans-serif;\n  }\n\n  .app-item {\n    display: flex;\n    flex-direction: column;\n    align-items: center;\n    cursor: pointer;\n  }\n\n  .app-item img {\n    width: 100%;\n    aspect-ratio: 3 \/ 2;\n    object-fit: cover;\n    border-radius: 6px;\n    transition: transform 0.3s ease, box-shadow 0.3s ease;\n  }\n\n  .app-item img:hover {\n    transform: translateY(-8px) scale(1.03);\n    box-shadow: 0 16px 40px rgba(0, 0, 0, 0.18);\n  }\n\n  .app-item span {\n    margin-top: 10px;\n    font-size: 13px;\n    font-weight: 600;\n    color: #222;\n    text-align: center;\n    letter-spacing: 0.3px;\n  }\n\n  \/* Lightbox overlay *\/\n  .app-lightbox {\n    display: none;\n    position: fixed;\n    inset: 0;\n    background: rgba(0, 0, 0, 0.75);\n    z-index: 9999;\n    justify-content: center;\n    align-items: center;\n    animation: fadeIn 0.25s ease;\n  }\n\n  .app-lightbox.active {\n    display: flex;\n  }\n\n  .app-lightbox img {\n    max-width: 80vw;\n    max-height: 80vh;\n    border-radius: 10px;\n    box-shadow: 0 24px 80px rgba(0,0,0,0.5);\n    animation: floatIn 0.35s cubic-bezier(0.34, 1.56, 0.64, 1);\n  }\n\n  .app-lightbox-close {\n    position: absolute;\n    top: 24px;\n    right: 32px;\n    font-size: 36px;\n    color: #fff;\n    cursor: pointer;\n    line-height: 1;\n    user-select: none;\n  }\n\n  @keyframes fadeIn {\n    from { opacity: 0; }\n    to   { opacity: 1; }\n  }\n\n  @keyframes floatIn {\n    from { opacity: 0; transform: scale(0.8) translateY(30px); }\n    to   { opacity: 1; transform: scale(1) translateY(0); }\n  }\n\u003c\/style\u003e\n\u003c!-- Application Images Grid --\u003e\n\u003cdiv class=\"app-grid\"\u003e\n\u003cdiv class=\"app-item\"\u003e\n\u003cimg alt=\"Pharmaceutical Research\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/pharmaceutical-development.png?v=1784796668\"\u003e \u003cspan\u003ePharmaceutical Research\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"app-item\"\u003e\n\u003cimg alt=\"Biological Laboratories\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/laboratory-research-no-people.png?v=1784796686\"\u003e \u003cspan\u003eBiological Laboratories\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"app-item\"\u003e\n\u003cimg alt=\"Micro-Volume Liquid Infusion\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/iridescent-droplets-white-background.png?v=1784796697\"\u003e \u003cspan\u003eMicro-Volume Liquid Infusion\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"app-item\"\u003e\n\u003cimg alt=\"Chemistry\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/chromatography-glass-columns.png?v=1784796717\"\u003e \u003cspan\u003eChemistry\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- Lightbox --\u003e\n\u003cdiv id=\"appLightbox\" class=\"app-lightbox\"\u003e\n\u003cspan class=\"app-lightbox-close\"\u003e×\u003c\/span\u003e \u003cimg alt=\"\" id=\"lightboxImg\"\u003e\n\u003c\/div\u003e\n\u003ch2 class=\"section-title\"\u003eFeatures\u003c\/h2\u003e\n\u003cp\u003e\u003cimg style=\"display: block; margin: 0 auto; max-width: 85%; height: auto;\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/SP-09-1.png?v=1783059606\" alt=\"\"\u003e\u003c\/p\u003e\n\u003ch2 class=\"section-title3\"\u003eMore Details\u003c\/h2\u003e\n\u003cp\u003e\u003cimg style=\"display: block; margin: 0 auto; max-width: 85%; height: auto;\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/SP-09-2.png?v=1783061563\"\u003e\u003c\/p\u003e\n\u003ch2 class=\"section-title3\"\u003ePacking List\u003c\/h2\u003e\n\u003cp class=\"section-description\"\u003e\u003cspan\u003e\u003cspan class=\"\"\u003eSyringe Pump *1, Power Cable *1, Syringe *2.\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 class=\"section-title3\"\u003eUser Manual\u003c\/h2\u003e\n\u003cp class=\"section-description\"\u003e\u003cspan\u003eFor detailed information on installation, setup, and usage, please refer to the \u003ca rel=\"noopener\" href=\"http:\/\/file.ussolid.com\/content\/JFSP\/User_Manual_Syringe_Pump_Numeric_Keypad_EN.pdf\" target=\"_blank\"\u003euser manual\u003c\/a\u003e\u003c\/span\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 class=\"section-title4\"\u003eContinuous Flow Principle\u003c\/h2\u003e\n\u003cdiv style=\"display: flex; align-items: center; gap: 40px; flex-wrap: wrap;\"\u003e\n\u003cdiv style=\"flex: 1; min-width: 300px;\"\u003e\n\u003cp class=\"section-description\"\u003eDuring operation, one syringe dispenses liquid while the other simultaneously refills.\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003eOnce the dispensing syringe reaches its target volume, the two syringe channels automatically exchange roles. \u003c\/p\u003e\n\u003cp class=\"section-description\"\u003eWhen combined with external check valves and T-valves, this alternating cycle enables smooth continuous fluid delivery for long-duration laboratory applications, with minimal interruption during channel switching.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2 class=\"section-title4\"\u003eTechnical Data\u003c\/h2\u003e\n\u003cp class=\"mobile-scroll-note\"\u003e\u003cspan style=\"margin-right: 5px;\"\u003e↔️\u003c\/span\u003e \u003cem\u003eScroll left or right to view full details\u003c\/em\u003e\u003c\/p\u003e\n\u003cdiv class=\"parameters-table-wrapper\"\u003e\n\u003ctable class=\"parameters-table\" style=\"width: 100%;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 16.0267%;\"\u003eSKU\u003c\/th\u003e\n\u003ctd style=\"width: 35.5593%;\"\u003eJFSP00009\u003c\/td\u003e\n\u003cth style=\"width: 20.8681%;\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"width: 27.379%;\"\u003eUSS-SP00009\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 16.0267%;\"\u003ePump Type\u003c\/th\u003e\n\u003ctd style=\"width: 35.5593%;\"\u003eDual-Channel Continuous Infuse\/Withdraw Syringe Pump\u003c\/td\u003e\n\u003cth style=\"width: 20.8681%;\"\u003eChannels\u003c\/th\u003e\n\u003ctd style=\"width: 27.379%;\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 16.0267%;\"\u003eFlow Rate Range\u003c\/th\u003e\n\u003ctd style=\"width: 35.5593%;\"\u003e0.001 μL\/min - 36.859 mL\/min\u003c\/td\u003e\n\u003cth style=\"width: 20.8681%;\"\u003eCompatible Syringe Size\u003c\/th\u003e\n\u003ctd style=\"width: 27.379%;\"\u003e10 μL - 20 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 16.0267%;\"\u003eOperating Modes\u003c\/th\u003e\n\u003ctd style=\"width: 35.5593%;\"\u003eInfuse, Withdraw, Withdraw\u003cspan\u003e-then-\u003c\/span\u003eInfuse, Infuse\u003cspan\u003e-then-\u003c\/span\u003eWithdraw, Continuous Operation\u003c\/td\u003e\n\u003cth style=\"width: 20.8681%;\"\u003eMaximum Stroke\u003c\/th\u003e\n\u003ctd style=\"width: 27.379%;\"\u003e140 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 16.0267%;\"\u003eStroke Resolution\u003c\/th\u003e\n\u003ctd style=\"width: 35.5593%;\"\u003e0.156 μm\u003c\/td\u003e\n\u003cth style=\"width: 20.8681%;\"\u003eLinear Speed\u003c\/th\u003e\n\u003ctd style=\"width: 27.379%;\"\u003e5 μm\/min - 65 mm\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 16.0267%;\"\u003eDisplay\u003c\/th\u003e\n\u003ctd style=\"width: 35.5593%;\"\u003eLCD Screen\u003c\/td\u003e\n\u003cth style=\"width: 20.8681%;\"\u003eAccuracy\u003c\/th\u003e\n\u003ctd style=\"width: 27.379%;\"\u003e\n\u003cspan\u003eError \u003c\/span\u003e\u003cspan lang=\"EN-US\"\u003e≤±0.5% \u003cspan class=\"\"\u003e(when the stroke is at least 30% of the maximum stroke)\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 16.0267%;\"\u003eLinear Force\u003c\/th\u003e\n\u003ctd style=\"width: 35.5593%;\"\u003e250 N\u003c\/td\u003e\n\u003cth style=\"width: 20.8681%;\"\u003eCommunication Interface\u003c\/th\u003e\n\u003ctd style=\"width: 27.379%;\"\u003eRS485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 16.0267%;\"\u003eCalibration Function\u003c\/th\u003e\n\u003ctd style=\"width: 35.5593%;\"\u003eSupported\u003c\/td\u003e\n\u003cth style=\"width: 20.8681%;\"\u003eMemory Function\u003c\/th\u003e\n\u003ctd style=\"width: 27.379%;\"\u003ePower-Off Memory\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 16.0267%;\"\u003ePower Supply\u003c\/th\u003e\n\u003ctd style=\"width: 35.5593%;\"\u003eAC 90-260V, 15W\u003c\/td\u003e\n\u003cth style=\"width: 20.8681%;\"\u003eNet Weight\u003c\/th\u003e\n\u003ctd style=\"width: 27.379%;\"\u003e3.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 16.0267%;\"\u003eDimensions\u003c\/th\u003e\n\u003ctd style=\"width: 35.5593%;\"\u003e280 × 210 × 140 mm\u003c\/td\u003e\n\u003cth style=\"width: 20.8681%;\"\u003eOperating Temperature\u003c\/th\u003e\n\u003ctd style=\"width: 27.379%;\"\u003e0°C - 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 16.0267%;\"\u003eOperating Humidity\u003c\/th\u003e\n\u003ctd style=\"width: 35.5593%;\"\u003e\u0026lt;80% RH\u003c\/td\u003e\n\u003cth style=\"width: 20.8681%;\"\u003eSyringe Selection\u003c\/th\u003e\n\u003ctd style=\"width: 27.379%;\"\u003eBuilt-in \u0026amp; Custom Syringe Configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch2 class=\"section-title\"\u003eFAQ\u003c\/h2\u003e\n\u003cp class=\"faq-question\"\u003e1. How is this different from a standard syringe pump?\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003eUnlike a standard syringe pump that must stop when the syringe reaches the end of its stroke, this continuous syringe pump alternates between two synchronized syringes. While one syringe dispenses liquid, the other refills, helping provide uninterrupted liquid delivery for long-duration experiments.\u003c\/p\u003e\n\u003cp class=\"faq-question\"\u003e2. Do I need external valves for continuous operation?\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003eYes. Continuous liquid delivery requires external check valves and T-valves. These components help direct the liquid flow during syringe switching and are shown in the connection diagram above.\u003c\/p\u003e\n\u003cp class=\"faq-question\"\u003e3. How does the continuous liquid supply work?\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003eOne syringe dispenses while the other refills. Once the dispensing syringe reaches the target volume, the two syringes automatically exchange roles. With external check valves and T-valves, this alternating cycle helps maintain continuous liquid delivery.\u003c\/p\u003e\n\u003cp class=\"faq-question\"\u003e4. What operating modes are available?\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003eThe pump supports five operating modes: Infusion, Withdrawal, Withdraw-then-Infuse, Infuse-then-Withdraw, and Continuous operation.\u003c\/p\u003e\n\u003cp class=\"faq-question\"\u003e5. What flow rates can this pump achieve?\u003c\/p\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 30px; align-items: flex-start;\"\u003e\n\u003cdiv style=\"flex: 1; min-width: 280px;\"\u003e\n\u003cp class=\"section-description\"\u003eThe available flow rate depends on the syringe diameter and the pump's linear speed. Smaller syringes provide ultra-low flow rates for precision dispensing, while larger syringes allow higher flow rates for larger-volume transfer.\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003eThis pump supports syringe sizes from \u003cstrong\u003e10 μL to 20 mL\u003c\/strong\u003e. Additional syringe sizes can be configured by selecting from the built-in syringe library or entering a custom syringe inner diameter.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; min-width: 340px;\"\u003e\n\u003cdiv class=\"parameters-table-wrapper\"\u003e\n\u003ctable class=\"parameters-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSyringe Size\u003c\/th\u003e\n\u003cth\u003eReference Flow Rate\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10 μL\u003c\/td\u003e\n\u003ctd\u003e0.001 μL\/min – 0.0128 mL\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e100 μL\u003c\/td\u003e\n\u003ctd\u003e0.0101 μL\/min – 0.1307 mL\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1 mL\u003c\/td\u003e\n\u003ctd\u003e0.0875 μL\/min – 1.1373 mL\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10 mL\u003c\/td\u003e\n\u003ctd\u003e1.0821 μL\/min – 14.068 mL\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e20 mL\u003c\/td\u003e\n\u003ctd\u003e1.4176 μL\/min – 36.859 mL\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp class=\"faq-question\"\u003e6. Can I use syringes that are not listed in the built-in library?\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003eYes. The pump includes a built-in syringe library and also supports manual entry of custom syringe inner diameters.\u003c\/p\u003e\n\u003cp class=\"faq-question\"\u003e7. Can the pump be controlled by a computer?\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003eYes. The built-in RS485 communication interface allows connection with external control systems for laboratory automation.\u003c\/p\u003e\n\u003cp class=\"faq-question\"\u003e8. How does the pump ensure reliable operation?\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003eThe pump includes flow calibration for improved dispensing accuracy, Stall protection that stops operation if excessive resistance is detected, and power-off memory that retains operating parameters after a power interruption.\u003c\/p\u003e\n\u003cp class=\"faq-question\"\u003e9. Is this pump suitable for microfluidic applications?\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003eYes. With flow rates as low as \u003cstrong\u003e0.001 μL\/min\u003c\/strong\u003e, this pump is suitable for microfluidics and other low-flow precision liquid handling applications.\u003c\/p\u003e\n\u003cp class=\"faq-question\"\u003e10. Is this syringe pump intended for medical or clinical use?\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003eNo. This product is designed for laboratory research and scientific applications only. It is not intended for clinical, diagnostic, or patient infusion use.\u003c\/p\u003e\n\u003cp class=\"faq-question\"\u003e11. What warranty does this syringe pump include?\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003eWe offer a one-year quality warranty. See more about our \u003ca href=\"https:\/\/ussolid.com\/policies\/refund-policy\"\u003ereturn policy\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch2 class=\"section-title3\"\u003eAll Options\u003c\/h2\u003e\n\u003cdiv class=\"options-section\"\u003e\n\u003cdiv class=\"options-card\"\u003e\n\u003ch3 class=\"options-title\"\u003eExplore Our Full Range of Syringe Pump Options\u003c\/h3\u003e\n\u003cp class=\"options-description\"\u003eWe offer a variety of models with different flow rates, channel numbers, accuracy, and linear force to meet your specific fluid transfer requirements.\u003c\/p\u003e\n\u003ca class=\"options-btn\" href=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFSP\/JFSP-options-101.html\" target=\"_blank\"\u003e VIEW MODEL SELECTION TABLE \u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"U.S. Solid","offers":[{"title":"Default Title","offer_id":48696509235455,"sku":"JFSP00009","price":1799.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/2_15aa402e-213f-4143-aaa9-30986e6253d1.jpg?v=1781587771","url":"https:\/\/ussolid.com\/products\/continuous-flow-dual-channel-laboratory-syringe-pump","provider":"U.S. Solid","version":"1.0","type":"link"}