{"product_id":"dual-channel-lab-syringe-pump-0-7-pl-min-0-1-accuracy-touchscreen","title":"Dual-Channel Lab Syringe Pump, 0.7 pL\/min, ±0.1% Accuracy, Touchscreen","description":"\u003cstyle\u003e     .options-section {\n    margin: 30px 0 20px;\n    font-family: Arial;\n}\n\n.options-card {\n    padding: 25px 30px;\n    border: 1px solid #f0f0f0;\n    background-color: #fafafa;\n    text-align: center;\n    border-radius: 8px;\n}\n\n.options-title {\n    font-size: 20px;\n    margin-bottom: 10px;\n    color: #333;\n    font-weight: bold;\n}\n\n.options-description {\n    font-size: 15px;\n    color: #666;\n    margin-bottom: 20px;\n    line-height: 1.5;\n}\n\n.options-btn {\n    display: inline-block;\n    padding: 15px 40px;\n    background-color: #2aa79b !important; \n    color: #FFFFFF !important;\n    text-decoration: none !important;\n    border-radius: 50px !important;\n    font-weight: bold !important;\n    box-shadow: 0 4px 6px rgba(0,0,0,0.1) !important;\n    transition: all 0.3s ease !important;\n    border: none !important;\n    cursor: pointer !important;\n    font-size: 16px !important;\n    letter-spacing: 0.5px !important;\n}\n\n.options-btn:hover {\n    background-color: #239087 !important;  \n    color: #FFFFFF !important;\n    transform: translateY(-2px) !important;\n    box-shadow: 0 6px 12px rgba(0,0,0,0.15) !important;\n}\n\n.options-btn:active {\n    background-color: #1e7f77 !important;  \n    color: #FFFFFF !important;\n    transform: translateY(0) !important;\n    box-shadow: 0 2px 4px rgba(0,0,0,0.1) !important;\n}\n  .faq-question {\n    background-color: #f2f2f2;\n    padding: 6px 8px;\n    margin: 15px 0 5px;\n    font-size: 16px;\n    line-height: 20px;\n    font-weight: bold;\n    font-family: Arial;\n    color: #000;\n}\n  \n  .section-title,\n  .section-title2,\n  .section-title3 {\n    font-size: 22px;\n    line-height: 22px;\n    font-weight: bold;\n    font-family: Arial;\n    color: #000;\n  }\n\n  .section-title {\n    margin: 15px 0 5px;\n  }\n\n  .section-title2 {\n    margin: 15px 0 3px;\n  }\n\n  .section-title3 {\n    margin: 15px 0 10px;\n  }\n\n  .section-description {\n    font-size: 16px;\n    line-height: 26px;\n    margin-bottom: 20px;\n    margin-top: 10px;\n    color: black;\n    font-family: Arial;\n  }\n\n  .section-description2 {\n    font-size: 16px;\n    line-height: 26px;\n    margin: 0;\n    font-family: Arial;\n    color: black;\n  }\n\n  .features-list {\n    padding-left: 22px;\n    margin: 0;\n  }\n\n  .parameters-table-wrapper {\n    width: 100%;\n    overflow-x: hidden;\n    margin-top: 0;\n  }\n\n  .parameters-table {\n    width: 100%;\n    border-collapse: collapse;\n    background-color: #fff;\n    font-family: Arial;\n    table-layout: fixed;\n  }\n\n  .parameters-table td {\n    border-top: 1px solid #a6a6a6;\n    border-bottom: 1px solid #a6a6a6;\n    border-left: none;\n    border-right: none;\n    padding: 3px 6px;\n    text-align: left;\n    font-size: 15px;\n    line-height: 18px;\n    color: #2c2c2c;\n    vertical-align: middle;\n  }\n\n  .parameters-table .bg-gray {\n    background-color: #f2f2f2;\n    font-weight: bold;\n  }\n\n  .table-note {\n    font-size: 14px;\n    line-height: 22px;\n    margin: 6px 0 0;\n    font-family: Arial;\n    color: #666;\n  }\n\n  @media (max-width: 768px) {\n    .parameters-table-wrapper {\n      overflow-x: auto;\n      -webkit-overflow-scrolling: touch;\n    }\n\n    .parameters-table {\n      min-width: 600px;\n      table-layout: auto;\n    }\n\n    .parameters-table td {\n      font-size: 13px;\n      padding: 6px 5px;\n      line-height: 18px;\n      border-top: 1.5px solid #a6a6a6;\n      border-bottom: 1.5px solid #a6a6a6;\n    }\n  }\n\n  @media (max-width: 480px) {\n    .parameters-table td {\n      font-size: 12px;\n      padding: 5px 4px;\n      line-height: 16px;\n      border-top: 1.5px solid #a6a6a6;\n      border-bottom: 1.5px solid #a6a6a6;\n    }\n  }\n\u003c\/style\u003e\n\u003ch2 class=\"section-title\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/ChatGPT_Image_Aug_28_2026_03_03_32_PM.png?v=1787900647\" alt=\"\"\u003e\u003c\/h2\u003e\n\u003ch2 class=\"section-title\"\u003eIntroduction\u003c\/h2\u003e\n\u003cp class=\"section-description\"\u003e\u003cspan\u003eThis U.S.Solid dual-channel smart laboratory syringe pump is designed for high-precision liquid infusion and withdrawal in laboratory applications. With a 2-channel design, a minimum flow rate as low as 0.0007 nL\/min (0.7 pL\/min), and a maximum flow rate up to 109.1360 mL\/min, it supports syringe sizes from 0.5 μL to 60 mL. The pump supports multiple operation modes, including infusion, withdrawal, infusion\/withdrawal, withdrawal\/infusion, cyclic infuse\/withdraw, and multiple infusion. Featuring a large 5-inch HD touch screen, ≤±0.1% stroke control accuracy, and 160 N linear force, it provides precise, stable, and user-friendly fluid control for various applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 class=\"section-title\"\u003eApplications\u003c\/h2\u003e\n\u003cstyle\u003e\n  .app-grid {\n    display: grid;\n    grid-template-columns: repeat(4, 1fr);\n    gap: 16px;\n    margin: 30px 0 20px;\n    font-family: 'Helvetica Neue', Arial, sans-serif;\n  }\n\n  .app-item {\n    display: flex;\n    flex-direction: column;\n    align-items: center;\n    cursor: pointer;\n  }\n\n  .app-item img {\n    width: 100%;\n    aspect-ratio: 3 \/ 2;\n    object-fit: cover;\n    border-radius: 6px;\n    transition: transform 0.3s ease, box-shadow 0.3s ease;\n  }\n\n  .app-item img:hover {\n    transform: translateY(-8px) scale(1.03);\n    box-shadow: 0 16px 40px rgba(0, 0, 0, 0.18);\n  }\n\n  .app-item span {\n    margin-top: 10px;\n    font-size: 13px;\n    font-weight: 600;\n    color: #222;\n    text-align: center;\n    letter-spacing: 0.3px;\n  }\n\n  \/* Lightbox overlay *\/\n  .app-lightbox {\n    display: none;\n    position: fixed;\n    inset: 0;\n    background: rgba(0, 0, 0, 0.75);\n    z-index: 9999;\n    justify-content: center;\n    align-items: center;\n    animation: fadeIn 0.25s ease;\n  }\n\n  .app-lightbox.active {\n    display: flex;\n  }\n\n  .app-lightbox img {\n    max-width: 80vw;\n    max-height: 80vh;\n    border-radius: 10px;\n    box-shadow: 0 24px 80px rgba(0,0,0,0.5);\n    animation: floatIn 0.35s cubic-bezier(0.34, 1.56, 0.64, 1);\n  }\n\n  .app-lightbox-close {\n    position: absolute;\n    top: 24px;\n    right: 32px;\n    font-size: 36px;\n    color: #fff;\n    cursor: pointer;\n    line-height: 1;\n    user-select: none;\n  }\n\n  @keyframes fadeIn {\n    from { opacity: 0; }\n    to   { opacity: 1; }\n  }\n\n  @keyframes floatIn {\n    from { opacity: 0; transform: scale(0.8) translateY(30px); }\n    to   { opacity: 1; transform: scale(1) translateY(0); }\n  }\n\u003c\/style\u003e\n\u003c!-- Application Images Grid --\u003e\n\u003cdiv class=\"app-grid\"\u003e\n\u003cdiv class=\"app-item\"\u003e\n\u003cimg alt=\"Pharmaceutical Research\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/pharmaceutical-development.png?v=1784796668\"\u003e \u003cspan\u003ePharmaceutical Research\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"app-item\"\u003e\n\u003cimg alt=\"Biological Laboratories\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/laboratory-research-no-people.png?v=1784796686\"\u003e \u003cspan\u003eBiological Laboratories\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"app-item\"\u003e\n\u003cimg alt=\"Micro-Volume Liquid Infusion\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/iridescent-droplets-white-background.png?v=1784796697\"\u003e \u003cspan\u003eMicro-Volume Liquid Infusion\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"app-item\"\u003e\n\u003cimg alt=\"Chemistry\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/chromatography-glass-columns.png?v=1784796717\"\u003e \u003cspan\u003eChemistry\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- Lightbox --\u003e\n\u003cdiv id=\"appLightbox\" class=\"app-lightbox\"\u003e\n\u003cspan class=\"app-lightbox-close\"\u003e×\u003c\/span\u003e \u003cimg alt=\"\" id=\"lightboxImg\"\u003e\n\u003c\/div\u003e\n\u003ch2 class=\"section-title\"\u003eFeatures\u003c\/h2\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/SP13-FEATURES-0813.png?v=1786601686\" alt=\"\" style=\"display: block; margin: 0 auto; max-width: 80%; height: auto;\"\u003e\u003c\/p\u003e\n\u003ch2 class=\"section-title3\"\u003eMore Details\u003c\/h2\u003e\n\u003cp class=\"section-description\"\u003e\u003cspan\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/SP13-15-MORE-DETAILS.png?v=1786602195\" alt=\"\" style=\"display: block; margin: 0 auto; max-width: 80%; height: auto;\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 class=\"section-title3\"\u003ePacking List\u003c\/h2\u003e\n\u003cp class=\"section-description2\"\u003eSyringe Pump *1, Power Cable *1, Syringe *2.\u003c\/p\u003e\n\u003ch2 class=\"section-title\"\u003eUser Manual\u003c\/h2\u003e\n\u003cp class=\"section-description\"\u003e\u003cspan\u003eFor detailed information on installation, setup, and usage, please refer to the \u003ca href=\"http:\/\/file.ussolid.com\/content\/JFSP\/SP_User_Manual_SP13-15.pdf\" title=\"User_Manual\" rel=\"noopener\" target=\"_blank\"\u003euser manual\u003c\/a\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 class=\"section-title3\"\u003eTechnical Data\u003c\/h2\u003e\n\u003cdiv class=\"parameters-table-wrapper\"\u003e\n\u003ctable class=\"parameters-table\" style=\"width: 100%;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\" style=\"width: 17.1953%;\"\u003eSKU\u003c\/td\u003e\n\u003ctd style=\"width: 25.2454%;\"\u003eJFSP00018\u003c\/td\u003e\n\u003ctd class=\"bg-gray\" style=\"width: 18.03%;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"width: 35.5292%;\"\u003eUSS-SP00018\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\" style=\"width: 17.1953%;\"\u003ePump Type\u003c\/td\u003e\n\u003ctd style=\"width: 25.2454%;\"\u003eDual-Channel Smart Infuse\/Withdraw Syringe Pump\u003c\/td\u003e\n\u003ctd class=\"bg-gray\" style=\"width: 18.03%;\"\u003eChannels\u003c\/td\u003e\n\u003ctd style=\"width: 35.5292%;\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\" style=\"width: 17.1953%;\"\u003eLinear Force\u003c\/td\u003e\n\u003ctd style=\"width: 25.2454%;\"\u003e160 N\u003c\/td\u003e\n\u003ctd class=\"bg-gray\" style=\"width: 18.03%;\"\u003eOperating Modes\u003c\/td\u003e\n\u003ctd style=\"width: 35.5292%;\"\u003eInfuse, Withdraw, Infuse\/Withdraw, Withdraw\/Infuse, \u003cspan\u003eCyclic infuse\/withdraw, Multiple Infusion\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\" style=\"width: 17.1953%;\"\u003eFlow Rate Range\u003c\/td\u003e\n\u003ctd style=\"width: 25.2454%;\"\u003e0.0007 nL\/min - 109.1360 mL\/min\u003c\/td\u003e\n\u003ctd class=\"bg-gray\" style=\"width: 18.03%;\"\u003eCompatible Syringe Size\u003c\/td\u003e\n\u003ctd style=\"width: 35.5292%;\"\u003e0.5 μL - 60 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\" style=\"width: 17.1953%;\"\u003eMaximum Stroke\u003c\/td\u003e\n\u003ctd style=\"width: 25.2454%;\"\u003e150 mm\u003c\/td\u003e\n\u003ctd class=\"bg-gray\" style=\"width: 18.03%;\"\u003eStepping Resolution\u003c\/td\u003e\n\u003ctd style=\"width: 35.5292%;\"\u003e0.0625 μm\/μstep\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\" style=\"width: 17.1953%;\"\u003eLinear Speed\u003c\/td\u003e\n\u003ctd style=\"width: 25.2454%;\"\u003e0.08 μm\/min - 160 mm\/min\u003c\/td\u003e\n\u003ctd class=\"bg-gray\" style=\"width: 18.03%;\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd style=\"width: 35.5292%;\"\u003eError ≤±0.1% \u003cspan lang=\"EN-US\"\u003e\u003cspan class=\"\"\u003e(when the stroke is at least 30% of the maximum stroke)\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\" style=\"width: 17.1953%;\"\u003eDisplay\u003c\/td\u003e\n\u003ctd style=\"width: 25.2454%;\"\u003e5-inch HD Touch Screen (800 × 480)\u003c\/td\u003e\n\u003ctd class=\"bg-gray\" style=\"width: 18.03%;\"\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd style=\"width: 35.5292%;\"\u003eRS485\/USB Optional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\" style=\"width: 17.1953%;\"\u003eCalibration Function\u003c\/td\u003e\n\u003ctd style=\"width: 25.2454%;\"\u003eSupported\u003c\/td\u003e\n\u003ctd class=\"bg-gray\" style=\"width: 18.03%;\"\u003eSyringe Selection\u003c\/td\u003e\n\u003ctd style=\"width: 35.5292%;\"\u003e\u003cspan\u003eBuilt-in \u0026amp; Custom Syringe Configuration\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\" style=\"width: 17.1953%;\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd style=\"width: 25.2454%;\"\u003eAC 90-264V, 50\/60 Hz\u003c\/td\u003e\n\u003ctd class=\"bg-gray\" style=\"width: 18.03%;\"\u003eDimensions\u003c\/td\u003e\n\u003ctd style=\"width: 35.5292%;\"\u003e256 × 190 × 146 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"table-note\"\u003e*To view the full table on mobile, please swipe left or right on the screen.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch2 class=\"section-title\"\u003eFAQ\u003c\/h2\u003e\n\u003cp class=\"faq-question\"\u003e1. What operating modes are available?\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003eThis syringe pump supports six operating modes: \u003cstrong\u003eInfusion\u003c\/strong\u003e, \u003cstrong\u003eWithdrawal\u003c\/strong\u003e, \u003cstrong\u003eInfuse-then-Withdraw\u003c\/strong\u003e, \u003cstrong\u003eWithdraw-then-Infuse\u003c\/strong\u003e, \u003cstrong\u003eContinuous \u003cspan\u003einfuse\/withdraw operation\u003c\/span\u003e\u003c\/strong\u003e, and \u003cstrong\u003eMultiple Infusion\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003eThese modes allow the pump to handle simple dispensing, liquid withdrawal, bidirectional operation, continuous cycling, and repeated dosing workflows.\u003c\/p\u003e\n\u003cp class=\"faq-question\"\u003e2. What flow rates can this syringe pump achieve?\u003c\/p\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 30px; align-items: flex-start;\"\u003e\n\u003cdiv style=\"flex: 1; min-width: 280px;\"\u003e\n\u003cp class=\"section-description\"\u003eThe available flow range depends on the syringe inner diameter. Smaller syringes provide ultra-low flow rates for micro-volume applications, while larger syringes support higher flow rates.\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003eThe pump supports syringes from \u003cstrong\u003e0.5 μL to 60 mL\u003c\/strong\u003e. Use the reference values shown here to check whether your syringe and target flow rate are suitable.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; min-width: 340px;\"\u003e\n\u003cdiv class=\"parameters-table-wrapper\"\u003e\n\u003ctable class=\"parameters-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSyringe Size\u003c\/th\u003e\n\u003cth\u003eReference Flow Rate\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.5 μL\u003c\/td\u003e\n\u003ctd\u003e0.0007 nL\/min - 0.0013 mL\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5 μL\u003c\/td\u003e\n\u003ctd\u003e0.0074 nL\/min - 0.0148 mL\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e100 μL\u003c\/td\u003e\n\u003ctd\u003e0.1334 nL\/min - 0.2668 mL\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1 mL\u003c\/td\u003e\n\u003ctd\u003e1.4060 nL\/min - 2.8110 mL\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5 mL\u003c\/td\u003e\n\u003ctd\u003e9.6620 nL\/min - 19.3220 mL\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10 mL\u003c\/td\u003e\n\u003ctd\u003e13.8940 nL\/min - 27.7860 mL\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e30 mL\u003c\/td\u003e\n\u003ctd\u003e34.2870 nL\/min - 68.5730 mL\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e60 mL\u003c\/td\u003e\n\u003ctd\u003e54.5680 nL\/min - 109.1360 mL\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp class=\"faq-question\"\u003e3. What syringes are compatible with this pump?\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003eThe pump supports syringe capacities from \u003cstrong\u003e0.5 μL to 60 mL\u003c\/strong\u003e. Common syringe specifications are available in the built-in syringe library. If your syringe model is not included, you can manually enter the syringe inner diameter (ID), allowing the pump to calculate accurate flow rates.\u003c\/p\u003e\n\u003cp class=\"faq-question\"\u003e4. Can infusion and withdrawal use different flow rates?\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003eYes. In Infuse-then-Withdraw and Withdraw-then-Infuse modes, the infusion and withdrawal speeds can be configured independently. The interval between direction changes can also be set.\u003c\/p\u003e\n\u003cp class=\"faq-question\"\u003e5. Can the pump perform repeated dosing automatically?\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003eYes. Multiple Infusion mode allows you to set the volume of the repeated infusion step, the number of repetitions, and the interval between consecutive doses, making it suitable for repeated dispensing workflows.\u003c\/p\u003e\n\u003cp class=\"faq-question\"\u003e6. Can the pump be controlled by a computer or external signal?\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003eYes. The pump supports \u003cstrong\u003eUSB and RS485 communication\u003c\/strong\u003e using Modbus RTU. External start\/stop control is also available, and a footswitch interface is also provided.\u003c\/p\u003e\n\u003cp class=\"faq-question\"\u003e7. How does the pump ensure reliable operation?\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003eThe pump features built-in calibration for improved dispensing accuracy, automatic Stall protection that stops operation if excessive resistance is detected, and power-off memory that retains operating parameters after a power interruption.\u003c\/p\u003e\n\u003cp class=\"faq-question\"\u003e8. Is this pump suitable for my application?\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003eThis pump is suitable for laboratory applications including microfluidics, biological research, chemistry, pharmaceutical research, electrospinning, and other precision liquid-handling workflows.\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003eIf you are unsure, send us your \u003cstrong\u003esyringe size or inner diameter, required flow rate, operating mode, and communication requirements\u003c\/strong\u003e. Our team can help confirm compatibility before ordering.\u003c\/p\u003e\n\u003cp class=\"faq-question\"\u003e9. Is this syringe pump intended for medical or clinical use?\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003eNo. This product is intended exclusively for laboratory research and industrial fluid handling applications.\u003c\/p\u003e\n\u003cp class=\"faq-question\"\u003e10. What warranty does this syringe pump include?\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\u003cspan\u003eWe offer a one-year quality warranty. See more about our \u003c\/span\u003e\u003ca href=\"https:\/\/ussolid.com\/policies\/refund-policy\"\u003ereturn policy\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"faq-question\"\u003e11. \u003cspan class=\"\"\u003eWhat is the difference between this syringe pump and\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003eJFSP00011\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e?\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\u003cspan\u003eBoth pumps offer the same accuracy. This model supports a lower minimum flow rate \u003c\/span\u003e\u003cspan\u003e(0.7 pL\/min)\u003c\/span\u003e\u003cspan\u003e, making it better for very low-volume liquid delivery, and has a larger touch screen (5-inch).\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 class=\"section-title3\"\u003eAll Options\u003c\/h2\u003e\n\u003cdiv class=\"options-section\"\u003e\n\u003cdiv class=\"options-card\"\u003e\n\u003ch3 class=\"options-title\"\u003eExplore Our Full Range of Syringe Pump Options\u003c\/h3\u003e\n\u003cp class=\"options-description\"\u003eWe offer a variety of models with different flow rates, channel numbers, accuracy, and linear force to meet your specific fluid transfer requirements.\u003c\/p\u003e\n\u003ca href=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFSP\/JFSP-options-101.html\" class=\"options-btn\" target=\"_blank\"\u003e VIEW MODEL SELECTION TABLE \u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"U.S. Solid","offers":[{"title":"Default Title","offer_id":48713410085119,"sku":"JFSP00018","price":2449.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/ChatGPT_Image_Aug_28_2026_02_34_44_PM.png?v=1787898933","url":"https:\/\/ussolid.com\/products\/dual-channel-lab-syringe-pump-0-7-pl-min-0-1-accuracy-touchscreen","provider":"U.S. Solid","version":"1.0","type":"link"}