{"product_id":"multi-channel-laboratory-infuse-withdraw-syringe-pump-280n-thrust","title":"Multi-channel Laboratory Infuse\/Withdraw Syringe Pump, 280N Thrust","description":"\u003cstyle\u003e\n    .options-section {\n    margin: 30px 0 20px;\n    font-family: Arial;\n}\n\n.options-card {\n    padding: 25px 30px;\n    border: 1px solid #f0f0f0;\n    background-color: #fafafa;\n    text-align: center;\n    border-radius: 8px;\n}\n\n.options-title {\n    font-size: 20px;\n    margin-bottom: 10px;\n    color: #333;\n    font-weight: bold;\n}\n\n.options-description {\n    font-size: 15px;\n    color: #666;\n    margin-bottom: 20px;\n    line-height: 1.5;\n}\n\n.options-btn {\n    display: inline-block;\n    padding: 15px 40px;\n    background-color: #2aa79b !important; \n    color: #FFFFFF !important;\n    text-decoration: none !important;\n    border-radius: 50px !important;\n    font-weight: bold !important;\n    box-shadow: 0 4px 6px rgba(0,0,0,0.1) !important;\n    transition: all 0.3s ease !important;\n    border: none !important;\n    cursor: pointer !important;\n    font-size: 16px !important;\n    letter-spacing: 0.5px !important;\n}\n\n.options-btn:hover {\n    background-color: #239087 !important;  \n    color: #FFFFFF !important;\n    transform: translateY(-2px) !important;\n    box-shadow: 0 6px 12px rgba(0,0,0,0.15) !important;\n}\n\n.options-btn:active {\n    background-color: #1e7f77 !important;  \n    color: #FFFFFF !important;\n    transform: translateY(0) !important;\n    box-shadow: 0 2px 4px rgba(0,0,0,0.1) !important;\n}\n\n    .faq-question {\n    background-color: #f2f2f2;\n    padding: 6px 8px;\n    margin: 15px 0 5px;\n    font-size: 16px;\n    line-height: 20px;\n    font-weight: bold;\n    font-family: Arial;\n    color: #000;\n}\n  \n  .section-title,\n  .section-title2,\n  .section-title3 {\n    font-size: 22px;\n    line-height: 22px;\n    font-weight: bold;\n    font-family: Arial;\n    color: #000;\n  }\n\n  .section-title {\n    margin: 15px 0 5px;\n  }\n\n  .section-title2 {\n    margin: 15px 0 3px;\n  }\n\n  .section-title3 {\n    margin: 15px 0 10px;\n  }\n\n  .section-description {\n    font-size: 16px;\n    line-height: 26px;\n    margin-bottom: 20px;\n    margin-top: 10px;\n    color: black;\n    font-family: Arial;\n  }\n\n  .section-description2 {\n    font-size: 16px;\n    line-height: 26px;\n    margin: 0;\n    font-family: Arial;\n    color: black;\n  }\n\n  .features-list {\n    padding-left: 22px;\n    margin: 0;\n  }\n\n  .parameters-table-wrapper {\n    width: 100%;\n    overflow-x: hidden;\n    margin-top: 0;\n  }\n\n  .parameters-table {\n    width: 100%;\n    border-collapse: collapse;\n    background-color: #fff;\n    font-family: Arial;\n    table-layout: fixed;\n  }\n\n  .parameters-table td {\n    border-top: 1px solid #a6a6a6;\n    border-bottom: 1px solid #a6a6a6;\n    border-left: none;\n    border-right: none;\n    padding: 3px 6px;\n    text-align: left;\n    font-size: 15px;\n    line-height: 18px;\n    color: #2c2c2c;\n    vertical-align: middle;\n  }\n\n  .parameters-table .bg-gray {\n    background-color: #f2f2f2;\n    font-weight: bold;\n  }\n\n  .table-note {\n    font-size: 14px;\n    line-height: 22px;\n    margin: 6px 0 0;\n    font-family: Arial;\n    color: #666;\n  }\n\n  @media (max-width: 768px) {\n    .parameters-table-wrapper {\n      overflow-x: auto;\n      -webkit-overflow-scrolling: touch;\n    }\n\n    .parameters-table {\n      min-width: 600px;\n      table-layout: auto;\n    }\n\n    .parameters-table td {\n      font-size: 13px;\n      padding: 6px 5px;\n      line-height: 18px;\n      border-top: 1.5px solid #a6a6a6;\n      border-bottom: 1.5px solid #a6a6a6;\n    }\n  }\n\n  @media (max-width: 480px) {\n    .parameters-table td {\n      font-size: 12px;\n      padding: 5px 4px;\n      line-height: 16px;\n      border-top: 1.5px solid #a6a6a6;\n      border-bottom: 1.5px solid #a6a6a6;\n    }\n  }\n\u003c\/style\u003e\n\u003ch2 class=\"section-title\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/SP17-11.png?v=1788253855\" alt=\"\"\u003e\u003c\/h2\u003e\n\u003ch2 class=\"section-title\"\u003eIntroduction\u003c\/h2\u003e\n\u003cp class=\"section-description\"\u003e\u003cspan\u003eThe U.S.Solid 4-channel syringe pump is designed for laboratories that require reliable, repeatable, smooth and precise fluid delivery without the complexity or cost of high-end automation systems. It supports simultaneous operation of up to \u003cstrong\u003e4\u003c\/strong\u003e syringes, making it ideal for researchers who need higher throughput while maintaining accurate and stable flow control. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\u003cspan\u003eWith support for infusion and withdrawal, ultra-low flow rates down to \u003cstrong\u003e1 nL\/min\u003c\/strong\u003e, customizable syringe sizes, synchronized multi-channel fluid delivery, stall detection, power-loss memory, calibration, and RS485 communication, the pump provides the essential features required for most laboratory research applications. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\u003cspan\u003eWhether used in microfluidics, electrospinning, chemistry, materials research, pharmaceutical development, or biological laboratories, it delivers dependable performance for everyday scientific research.\u003cspan\u003e\u003c\/span\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 class=\"section-title\"\u003eApplications\u003c\/h2\u003e\n\u003cstyle\u003e\n  .app-grid {\n    display: grid;\n    grid-template-columns: repeat(4, 1fr);\n    gap: 16px;\n    margin: 30px 0 20px;\n    font-family: 'Helvetica Neue', Arial, sans-serif;\n  }\n\n  .app-item {\n    display: flex;\n    flex-direction: column;\n    align-items: center;\n    cursor: pointer;\n  }\n\n  .app-item img {\n    width: 100%;\n    aspect-ratio: 3 \/ 2;\n    object-fit: cover;\n    border-radius: 6px;\n    transition: transform 0.3s ease, box-shadow 0.3s ease;\n  }\n\n  .app-item img:hover {\n    transform: translateY(-8px) scale(1.03);\n    box-shadow: 0 16px 40px rgba(0, 0, 0, 0.18);\n  }\n\n  .app-item span {\n    margin-top: 10px;\n    font-size: 13px;\n    font-weight: 600;\n    color: #222;\n    text-align: center;\n    letter-spacing: 0.3px;\n  }\n\n  \/* Lightbox overlay *\/\n  .app-lightbox {\n    display: none;\n    position: fixed;\n    inset: 0;\n    background: rgba(0, 0, 0, 0.75);\n    z-index: 9999;\n    justify-content: center;\n    align-items: center;\n    animation: fadeIn 0.25s ease;\n  }\n\n  .app-lightbox.active {\n    display: flex;\n  }\n\n  .app-lightbox img {\n    max-width: 80vw;\n    max-height: 80vh;\n    border-radius: 10px;\n    box-shadow: 0 24px 80px rgba(0,0,0,0.5);\n    animation: floatIn 0.35s cubic-bezier(0.34, 1.56, 0.64, 1);\n  }\n\n  .app-lightbox-close {\n    position: absolute;\n    top: 24px;\n    right: 32px;\n    font-size: 36px;\n    color: #fff;\n    cursor: pointer;\n    line-height: 1;\n    user-select: none;\n  }\n\n  @keyframes fadeIn {\n    from { opacity: 0; }\n    to   { opacity: 1; }\n  }\n\n  @keyframes floatIn {\n    from { opacity: 0; transform: scale(0.8) translateY(30px); }\n    to   { opacity: 1; transform: scale(1) translateY(0); }\n  }\n\u003c\/style\u003e\n\u003c!-- Application Images Grid --\u003e\n\u003cdiv class=\"app-grid\"\u003e\n\u003cdiv class=\"app-item\"\u003e\n\u003cimg alt=\"Pharmaceutical Research\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/pharmaceutical-development.png?v=1784796668\"\u003e \u003cspan\u003ePharmaceutical Research\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"app-item\"\u003e\n\u003cimg alt=\"Biological Laboratories\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/laboratory-research-no-people.png?v=1784796686\"\u003e \u003cspan\u003eBiological Laboratories\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"app-item\"\u003e\n\u003cimg alt=\"Micro-Volume Liquid Infusion\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/iridescent-droplets-white-background.png?v=1784796697\"\u003e \u003cspan\u003eMicro-Volume Liquid Infusion\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"app-item\"\u003e\n\u003cimg alt=\"Chemistry\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/chromatography-glass-columns.png?v=1784796717\"\u003e \u003cspan\u003eChemistry\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- Lightbox --\u003e\n\u003cdiv id=\"appLightbox\" class=\"app-lightbox\"\u003e\n\u003cspan class=\"app-lightbox-close\"\u003e×\u003c\/span\u003e \u003cimg alt=\"\" id=\"lightboxImg\"\u003e\n\u003c\/div\u003e\n\u003ch2 class=\"section-title\"\u003eFeatures\u003c\/h2\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/SP-17-2.png?v=1782978278\" alt=\"\" style=\"display: block; margin: 0 auto; max-width: 80%; height: auto;\"\u003e\u003c\/p\u003e\n\u003ch2 class=\"section-title3\"\u003eMore Details\u003c\/h2\u003e\n\u003cp\u003e\u003cimg style=\"display: block; margin: 0 auto; max-width: 80%; height: auto;\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/SP-features-update.png?v=1783066708\"\u003e\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003e\u003cspan\u003eUnlike basic syringe pumps that perform only a single infusion or withdrawal, this pump allows independent configuration of infusion and withdrawal parameters, providing greater flexibility for repetitive laboratory procedures.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 class=\"section-title3\"\u003ePacking List\u003c\/h2\u003e\n\u003cp class=\"section-description2\"\u003eSyringe Pump *1, Power Cable *1, Syringe *2.\u003c\/p\u003e\n\u003ch2 class=\"section-title3\"\u003eUser Manual\u003c\/h2\u003e\n\u003cp class=\"section-description\"\u003e\u003cspan\u003eFor detailed information on installation, setup, and usage, please refer to the \u003ca href=\"http:\/\/file.ussolid.com\/content\/JFSP\/User_Manual_Syringe_Pump_Numeric_Keypad_EN.pdf\" rel=\"noopener\" target=\"_blank\"\u003euser manual\u003c\/a\u003e\u003c\/span\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 class=\"section-title3\"\u003eTechnical Data\u003c\/h2\u003e\n\u003cdiv class=\"parameters-table-wrapper\"\u003e\n\u003ctable class=\"parameters-table\" style=\"width: 100%;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\" style=\"width: 17.1953%;\"\u003eSKU\u003c\/td\u003e\n\u003ctd style=\"width: 25.2454%;\"\u003eJFSP00017\u003c\/td\u003e\n\u003ctd class=\"bg-gray\" style=\"width: 18.03%;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"width: 35.5292%;\"\u003eUSS-SP00017\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\" style=\"width: 17.1953%;\"\u003ePump Type\u003c\/td\u003e\n\u003ctd style=\"width: 25.2454%;\"\u003eMulti-Channel Infuse\/Withdraw Syringe Pump\u003c\/td\u003e\n\u003ctd class=\"bg-gray\" style=\"width: 18.03%;\"\u003eChannels\u003c\/td\u003e\n\u003ctd style=\"width: 35.5292%;\"\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\" style=\"width: 17.1953%;\"\u003eLinear Force\u003c\/td\u003e\n\u003ctd style=\"width: 25.2454%;\"\u003e280 N\u003c\/td\u003e\n\u003ctd class=\"bg-gray\" style=\"width: 18.03%;\"\u003eOperating Modes\u003c\/td\u003e\n\u003ctd style=\"width: 35.5292%;\"\u003e\n\u003cspan\u003eInfuse, Withdraw, Withdraw\u003c\/span\u003e\u003cspan\u003e-then-\u003c\/span\u003e\u003cspan\u003eInfuse, Infuse\u003c\/span\u003e\u003cspan\u003e-then-\u003c\/span\u003e\u003cspan\u003eWithdraw, \u003c\/span\u003e\u003cspan\u003eCyclic infuse\/withdraw operation\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\" style=\"width: 17.1953%;\"\u003eFlow Rate Range\u003c\/td\u003e\n\u003ctd style=\"width: 25.2454%;\"\u003e0.001 μL\/min - 36.859 mL\/min\u003c\/td\u003e\n\u003ctd class=\"bg-gray\" style=\"width: 18.03%;\"\u003eCompatible Syringe Size\u003c\/td\u003e\n\u003ctd style=\"width: 35.5292%;\"\u003e10 μL - 20 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\" style=\"width: 17.1953%;\"\u003eMaximum Stroke\u003c\/td\u003e\n\u003ctd style=\"width: 25.2454%;\"\u003e140 mm\u003c\/td\u003e\n\u003ctd class=\"bg-gray\" style=\"width: 18.03%;\"\u003eStepping Resolution\u003c\/td\u003e\n\u003ctd style=\"width: 35.5292%;\"\u003e0.156 μm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\" style=\"width: 17.1953%;\"\u003eLinear Speed\u003c\/td\u003e\n\u003ctd style=\"width: 25.2454%;\"\u003e5 μm\/min - 130 mm\/min\u003c\/td\u003e\n\u003ctd class=\"bg-gray\" style=\"width: 18.03%;\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd style=\"width: 35.5292%;\"\u003eError ≤±0.5% \u003cspan lang=\"EN-US\"\u003e\u003cspan class=\"\"\u003e(when the stroke is at least 30% of the maximum stroke)\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\" style=\"width: 17.1953%;\"\u003eDisplay\u003c\/td\u003e\n\u003ctd style=\"width: 25.2454%;\"\u003eLCD Display\u003c\/td\u003e\n\u003ctd class=\"bg-gray\" style=\"width: 18.03%;\"\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd style=\"width: 35.5292%;\"\u003eRS485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\" style=\"width: 17.1953%;\"\u003eCalibration Function\u003c\/td\u003e\n\u003ctd style=\"width: 25.2454%;\"\u003eSupported\u003c\/td\u003e\n\u003ctd class=\"bg-gray\" style=\"width: 18.03%;\"\u003eSyringe Selection\u003c\/td\u003e\n\u003ctd style=\"width: 35.5292%;\"\u003eBuilt-in Syringe List \u0026amp; Direct Inner Diameter Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"bg-gray\" style=\"width: 17.1953%;\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd style=\"width: 25.2454%;\"\u003eAC 90V-260V\/30W\u003c\/td\u003e\n\u003ctd class=\"bg-gray\" style=\"width: 18.03%;\"\u003eDimensions\u003c\/td\u003e\n\u003ctd style=\"width: 35.5292%;\"\u003e280 × 210 × 140 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"table-note\"\u003e*To view the full table on mobile, please swipe left or right on the screen.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch2 class=\"section-title\"\u003eFAQ\u003c\/h2\u003e\n\u003cp class=\"faq-question\"\u003e1. Why choose a four-channel syringe pump?\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003eA \u003cstrong\u003efour-channel\u003c\/strong\u003e syringe pump allows up to four syringes to run simultaneously under identical operating conditions. It helps increase laboratory throughput, improve experimental consistency, and reduce the time required for repetitive testing, making it ideal for parallel sample processing and screening applications.\u003c\/p\u003e\n\u003cp class=\"faq-question\"\u003e2. Can each syringe be set to a different flow rate?\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003eNo. All four syringes operate simultaneously using the same operating parameters. This synchronized design is ideal for running multiple samples under identical experimental conditions, helping improve repeatability and experimental consistency.\u003c\/p\u003e\n\u003cp class=\"faq-question\"\u003e3. What flow rates can this syringe pump achieve?\u003c\/p\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 30px; align-items: flex-start;\"\u003e\n\u003cdiv style=\"flex: 1; min-width: 280px;\"\u003e\n\u003cp class=\"section-description\"\u003eThe available flow rate depends on the syringe inner diameter. Smaller syringes provide lower flow rates for micro-volume applications, while larger syringes allow higher flow rates.\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003eThe USS-SP00017 supports syringe sizes from \u003cstrong\u003e10 μL to 20 mL\u003c\/strong\u003e. Use the reference values shown here to determine whether your syringe and target flow rate are suitable.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; min-width: 340px;\"\u003e\n\u003cdiv class=\"parameters-table-wrapper\"\u003e\n\u003ctable class=\"parameters-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSyringe Size\u003c\/th\u003e\n\u003cth\u003eReference Flow Rate\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10 μL\u003c\/td\u003e\n\u003ctd\u003e0.001 μL\/min – 0.0128 mL\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e50 μL\u003c\/td\u003e\n\u003ctd\u003e0.0048 μL\/min – 0.0618 mL\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e100 μL\u003c\/td\u003e\n\u003ctd\u003e0.0101 μL\/min – 0.1307 mL\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e500 μL\u003c\/td\u003e\n\u003ctd\u003e0.0415 μL\/min – 0.5392 mL\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1 mL\u003c\/td\u003e\n\u003ctd\u003e0.0875 μL\/min – 1.1373 mL\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10 mL\u003c\/td\u003e\n\u003ctd\u003e1.0821 μL\/min – 14.068 mL\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e20 mL\u003c\/td\u003e\n\u003ctd\u003e1.4176 μL\/min – 36.859 mL\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp class=\"faq-question\"\u003e4. What syringes are compatible with this pump?\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003eThe pump supports syringe sizes from \u003cstrong\u003e10 μL to 20 mL\u003c\/strong\u003e. Common syringe specifications can be selected from the built-in syringe library. If your syringe is not listed, you can directly enter the syringe inner diameter to configure a custom syringe.\u003c\/p\u003e\n\u003cp class=\"faq-question\"\u003e5. Can infusion and withdrawal use different settings?\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003eYes. In Infuse-then-Withdraw and Withdraw-then-Infuse modes, the infusion and withdrawal \u003cstrong\u003eflow rates and target volumes can be configured separately\u003c\/strong\u003e. An adjustable pause time can also be set between the two directions.\u003c\/p\u003e\n\u003cp class=\"faq-question\"\u003e6. Can the pump be controlled by a computer?\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003eYes. The built-in RS485 communication interface allows integration with external computer systems and laboratory automation. \u003c\/p\u003e\n\u003cp class=\"faq-question\"\u003e7. How does the pump ensure reliable operation?\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003eThe pump features built-in calibration for improved dispensing accuracy, automatic Stall protection that stops operation if excessive resistance is detected, and power-off memory that retains operating parameters after a power interruption.\u003c\/p\u003e\n\u003cp class=\"faq-question\"\u003e8. Is this syringe pump intended for medical or clinical use?\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003eNo. This product is designed for laboratory research and scientific applications only. It is not intended for clinical, diagnostic, or patient infusion use.\u003c\/p\u003e\n\u003cp class=\"faq-question\"\u003e9. What warranty does this syringe pump include?\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003eWe offer a one-year quality warranty. See more about our \u003ca href=\"https:\/\/ussolid.com\/policies\/refund-policy\"\u003ereturn policy\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp class=\"faq-question\"\u003e10. Not sure if this pump is suitable for your application?\u003c\/p\u003e\n\u003cp class=\"section-description\"\u003eSend us your syringe size, required flow rate, and operating mode. Our team can help confirm compatibility before ordering.\u003c\/p\u003e\n\u003ch2 class=\"section-title3\"\u003eAll Options\u003c\/h2\u003e\n\u003cdiv class=\"options-section\"\u003e\n\u003cdiv class=\"options-card\"\u003e\n\u003ch3 class=\"options-title\"\u003eExplore Our Full Range of Syringe Pump Options\u003c\/h3\u003e\n\u003cp class=\"options-description\"\u003eWe offer a variety of models with different flow rates, channel numbers, accuracy, and linear force to meet your specific fluid transfer requirements.\u003c\/p\u003e\n\u003ca href=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFSP\/JFSP-options-101.html\" class=\"options-btn\" target=\"_blank\"\u003e VIEW MODEL SELECTION TABLE \u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"U.S. Solid","offers":[{"title":"Default Title","offer_id":48710296436991,"sku":"JFSP00017","price":2399.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/SP17-1-new-panel.png?v=1788253881","url":"https:\/\/ussolid.com\/products\/multi-channel-laboratory-infuse-withdraw-syringe-pump-280n-thrust","provider":"U.S. Solid","version":"1.0","type":"link"}