{"product_id":"solenoid-valve-plastic-nylon-1-2-110-v-220-v-ac-8-bar-normally-closed-viton-seal","title":"Solenoid Valve Plastic (Nylon) 1\/2\" - 110 V \/ 220 V AC, 8 Bar, Normally Closed, VITON Seal","description":"\u003cbody\u003e \n\n\n    \u003cstyle\u003e\n        @media only screen and (max-width: 600px) {\n        }\n    \u003c\/style\u003e\n\n\n    \u003cdiv class=\"desktop-only\"\u003e\n       \n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFYSV\/002xx\/coverimage-002.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; line-height: 26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 10px; color: black; font-family: Arial;\"\u003eThe U.S. Solid industrial-grade solenoid valve is precision-engineered from corrosion-resistant nylon for long-lasting reliability in demanding environments. The Viton-sealed pilot-operated design delivers rapid response (≤100 ms) with consistent performance across 500,000+ cycles. These valves are available in 220\/110 VAC and 24\/12 VDC voltages and are constructed with Nylon bodies and viton seal materials. Featuring a high-quality coil, this solenoid valve efficiently controls the opening and closing of the diaphragm in under 1 second for precise flow control. Suitable for air and water, this valve is designed for reliable performance.\u003c\/p\u003e\n        \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFYSV\/002xx\/features-002.jpg\" style=\"flex: 1; margin:FEATURES 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFYSV\/002xx\/Applications-002.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cdiv style=\"width: 100%; overflow-x: auto;margin-top:20px;\"\u003e\n    \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"width: 50%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFNSV\/POLARITY.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n            \u003c\/td\u003e\n            \u003ctd valign=\"top\" style=\"width: 100%;text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e\n                \u003cp style=\"margin-top: 50px;margin-bottom: 0px;\"\u003e\u003cspan style=\"font-size: 22px; font-weight: bold;\"\u003ePOLARITY\u003c\/span\u003e\u003c\/p\u003e\n                \u003cp style=\"line-height: 2;margin-top:30px;\"\u003eWhen dealing with valves equipped with two wires, an important characteristic to note is their polarity - insensitive design. This means that the valve will actuate correctly regardless of which terminal each wire is connected to. Whether a wire is attached to the positive (+) or negative (-) terminal makes no difference in the valve’s operation. However, it’s essential to be aware that some valve units incorporate an additional ground wire.To determine if your valve has a ground wire, you’ll need to open up the connector.For valves with a ground wire, proper grounding is crucial. \u003c\/p\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/table\u003e\n\u003c\/div\u003e\n          \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e \n \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-YSV00201-G\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eU.S. Solid\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1\/2\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eFlow Aperture\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e15 mm\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNylon\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eVoltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eAC 110V\/220V ± 10%\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eCurrent\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e0.05 A\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eG\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003ePower Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e10 VA\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eFlow Rate\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e4.3 Cv\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperation Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003ePilot-operated\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperation Mode\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNormally Closed\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e≤100 ms\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003ePressure Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e0.01-0.8 Mpa (1.5-116 PSI)\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e-30°C ~ 150°C\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Life\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e500,000 cycles\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSuitable Media\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eAir, water\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Environment\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eIndoor\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP65. The first digit 6 indicates complete dust - tightness. The second digit 5 means protection against water jets from any direction. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFYSV\/JFYSV-IP65.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP65 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2. Can these solenoid valves be used continuously for extended periods?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThese valves should be energized for less than 8 hours. While most do not exceed 18W of power, the coils are in a contained area and can burn out if energized for too long. We recommend using a computer fan to keep the coil cool if continuous operation is necessary.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.How long should you wait between two consecutive five-hour uses of our solenoid valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIt is recommended to allow about 20 minutes of cooling time between two consecutive 5-hour operating sessions. The exact cooling time may vary depending on ambient temperature and operating conditions.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.Can it be used outdoors?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eWhile the solenoid valves have an IP65 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n    \u003c\/div\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:20px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual \u003ca href=\"http:\/\/file.ussolid.com\/content\/JFYSV\/Instruction%20Manual-JFYSV.pdf\" target=\"_blank\"\u003ehere\u003c\/a\u003e.\u003c\/p\u003e\n    \u003c\/div\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"mobile-only\"\u003e\n      \n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFYSV\/002xx\/coverimage-002.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; line-height:26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 0px; color: black; font-family: Arial;\"\u003eThe U.S. Solid industrial-grade solenoid valve is precision-engineered from corrosion-resistant nylon for long-lasting reliability in demanding environments. The Viton-sealed pilot-operated design delivers rapid response (≤100 ms) with consistent performance across 500,000+ cycles. These valves are available in 220\/110 VAC and 24\/12 VDC voltages and are constructed with Nylon bodies and viton seal materials. Featuring a high-quality coil, this solenoid valve efficiently controls the opening and closing of the diaphragm in under 1 second for precise flow control. Suitable for air and water, this valve is designed for reliable performance.\u003c\/p\u003e\n            \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFYSV\/002xx\/features-002-app.jpg\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-bottom:10px; margin-top:20px; color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n                 \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFYSV\/002xx\/Applications-002-app.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003c\/div\u003e\n   \u003cp style=\"font-size: 22px; text-align: left; margin-bottom:10px; margin-top:20px; color: black;\"\u003e\u003cstrong\u003ePOLARITY\u003c\/strong\u003e\u003c\/p\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eWhen dealing with valves equipped with two wires, an important characteristic to note is their polarity - insensitive design. This means that the valve will actuate correctly regardless of which terminal each wire is connected to. Whether a wire is attached to the positive (+) or negative (-) terminal makes no difference in the valve’s operation. However, it’s essential to be aware that some valve units incorporate an additional ground wire.To determine if your valve has a ground wire, you’ll need to open up the connector.For valves with a ground wire, proper grounding is crucial. \u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFNSV\/POLARITY.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n      \u003cp style=\"font-size: 16px; text-align: left; margin-bottom:10px; margin-top:20px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n          \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n    \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; background-color: #FFFFFF;\"\u003e\n        \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n            \u003cth style=\"width: 50%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black; word-break:keep-all;\"\u003eModel\u003c\/th\u003e\n            \u003ctd style=\"width: 44%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF; word-wrap:break-word;\"\u003eUSS-YSV00201-G\u003c\/td\u003e\n            \u003cth style=\"width: 50%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black; word-break:keep-all;\"\u003eBrand\u003c\/th\u003e\n            \u003ctd style=\"width: 44%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF; word-wrap:break-word;\"\u003eU.S. Solid\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n            \u003cth style=\"width: 50%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black; word-break:keep-all;\"\u003eSize\u003c\/th\u003e\n            \u003ctd style=\"width: 44%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF; word-wrap:break-word;\"\u003e1\/2\"\u003c\/td\u003e\n            \u003cth style=\"width: 50%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black; word-break:keep-all;\"\u003eFlow Aperture\u003c\/th\u003e\n            \u003ctd style=\"width: 44%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF; word-wrap:break-word;\"\u003e15 mm\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n            \u003cth style=\"width: 50%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black; word-break:keep-all;\"\u003eValve Material\u003c\/th\u003e\n            \u003ctd style=\"width: 44%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF; word-wrap:break-word;\"\u003eNylon\u003c\/td\u003e\n            \u003cth style=\"width: 50%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black; word-break:keep-all;\"\u003eVoltage\u003c\/th\u003e\n            \u003ctd style=\"width: 44%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF; word-wrap:break-word;\"\u003eAC 110V\/220V ± 10%\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n            \u003cth style=\"width: 50%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black; word-break:keep-all;\"\u003eCurrent\u003c\/th\u003e\n            \u003ctd style=\"width: 44%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF; word-wrap:break-word;\"\u003e0.05 A\u003c\/td\u003e\n            \u003cth style=\"width: 50%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black; word-break:keep-all;\"\u003eThread Type\u003c\/th\u003e\n            \u003ctd style=\"width: 44%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF; word-wrap:break-word;\"\u003eG\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n            \u003cth style=\"width: 50%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black; word-break:keep-all;\"\u003ePower Rating\u003c\/th\u003e\n            \u003ctd style=\"width: 44%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF; word-wrap:break-word;\"\u003e10 VA\u003c\/td\u003e\n            \u003cth style=\"width: 50%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black; word-break:keep-all;\"\u003eFlow Rate\u003c\/th\u003e\n            \u003ctd style=\"width: 44%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF; word-wrap:break-word;\"\u003e4.3 Cv\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n            \u003cth style=\"width: 50%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black; word-break:keep-all;\"\u003eOperation Type\u003c\/th\u003e\n            \u003ctd style=\"width: 44%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF; word-wrap:break-word;\"\u003ePilot-operated\u003c\/td\u003e\n            \u003cth style=\"width: 50%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black; word-break:keep-all;\"\u003eOperation Mode\u003c\/th\u003e\n            \u003ctd style=\"width: 44%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF; word-wrap:break-word;\"\u003eNormally Closed\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n            \u003cth style=\"width: 50%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black; word-break:keep-all;\"\u003eOperating Time\u003c\/th\u003e\n            \u003ctd style=\"width: 44%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF; word-wrap:break-word;\"\u003e≤100 ms\u003c\/td\u003e\n            \u003cth style=\"width: 50%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black; word-break:keep-all;\"\u003ePressure Range\u003c\/th\u003e\n            \u003ctd style=\"width: 44%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF; word-wrap:break-word;\"\u003e0.01-0.8 Mpa (1.5-116 PSI)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n            \u003cth style=\"width: 50%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black; word-break:keep-all;\"\u003eTemperature Range\u003c\/th\u003e\n            \u003ctd style=\"width: 44%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF; word-wrap:break-word;\"\u003e-30°C ~ 150°C\u003c\/td\u003e\n            \u003cth style=\"width: 50%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black; word-break:keep-all;\"\u003eWorking Life\u003c\/th\u003e\n            \u003ctd style=\"width: 44%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF; word-wrap:break-word;\"\u003e500,000 cycles\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003cth style=\"width: 50%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black; word-break:keep-all;\"\u003eSuitable Media\u003c\/th\u003e\n            \u003ctd style=\"width: 44%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF; word-wrap:break-word;\"\u003eAir, water\u003c\/td\u003e\n            \u003cth style=\"width: 50%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black; word-break:keep-all;\"\u003eOperating Environment\u003c\/th\u003e\n            \u003ctd style=\"width: 44%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF; word-wrap:break-word;\"\u003eIndoor\u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/table\u003e\n\u003c\/div\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP65. The first digit 6 indicates complete dust - tightness. The second digit 5 means protection against water jets from any direction. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFYSV\/JFYSV-IP65.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n       \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP65 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2. Can these solenoid valves be used continuously for extended periods?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThese valves should be energized for less than 8 hours. While most do not exceed 18W of power, the coils are in a contained area and can burn out if energized for too long. We recommend using a computer fan to keep the coil cool if continuous operation is necessary.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.How long should you wait between two consecutive five-hour uses of our solenoid valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIt is recommended to allow about 20 minutes of cooling time between two consecutive 5-hour operating sessions. The exact cooling time may vary depending on ambient temperature and operating conditions.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.Can it be used outdoors?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eWhile the solenoid valves have an IP65 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n    \u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual \u003ca href=\"http:\/\/file.ussolid.com\/content\/JFYSV\/Instruction%20Manual-JFYSV.pdf\" target=\"_blank\"\u003ehere\u003c\/a\u003e.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n    \u003cscript\u003e\n      \n        const isMobile = window.matchMedia(\"only screen and (max-width: 600px)\").matches;\n        const desktopContent = document.querySelector('.desktop-only');\n        const mobileContent = document.querySelector('.mobile-only');\n\n        if (isMobile) {\n           \n            console.log('');\n           \n            desktopContent.style.display = 'none';\n            mobileContent.style.display = 'block';\n        } else {\n            \n            console.log('');            \n            \n            desktopContent.style.display = 'block';\n            mobileContent.style.display = 'none';\n        }\n    \u003c\/script\u003e\n\n\n\n\u003c\/body\u003e","brand":"U.S. Solid","offers":[{"title":"G","offer_id":48075279007999,"sku":"JFYSV00201-G","price":30.29,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/3_352fe4f4-77e6-4ed0-8609-03ce45104e7e.jpg?v=1768901043","url":"https:\/\/ussolid.com\/products\/solenoid-valve-plastic-nylon-1-2-110-v-220-v-ac-8-bar-normally-closed-viton-seal","provider":"U.S. Solid","version":"1.0","type":"link"}