{"product_id":"us-solid-1-motorized-ball-valve-110220v-ac-stainless-steel-auto-return-normally-closed-with-plug-nsf-certified","title":"U.S. Solid 1\" Motorized Ball Valve, 110\/220V AC, Stainless Steel, Auto Return, Normally Closed, with Plug, NSF Certified","description":"\u003cbody\u003e \n\n\n    \u003cstyle\u003e\n        @media only screen and (max-width: 600px) {\n        }\n    \u003c\/style\u003e\n\n\n    \u003cdiv class=\"desktop-only\"\u003e\n        \u003c!--  --\u003e\n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; line-height: 26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 10px; color: black; font-family: Arial;\"\u003eMotorized ball valves present an energy-efficient substitute for solenoid valves, particularly when it comes to prolonged positioning. They primarily consume power during the processes of opening and closing, and the energy consumption is negligible once they are fully opened. This characteristic enables a permanent connection, eliminating the risks of overheating or burnout.\u003c\/p\u003e\n        \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/1-SS.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n             \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n    \u003ctable style=\"border-collapse: collapse;\n                  border: 0px;\n                  width: 100%;\n                  font-family: Arial;\n                  overflow-x: auto;\n                  background-color: #FFFFFF;\"\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"width: 100%;text-align: left;\n                       padding: 0px;\n                       font-size: 16px;\n                       border: 0;\n                       background-color: #FFFFFF;\"\u003e\n                \u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 1\" style=\"width: 100%;height: 100%;\"\u003e\n            \u003c\/td\u003e\n            \u003ctd style=\"width: 100%;text-align: left;\n                       padding: 0px;\n                       font-size: 16px;\n                       border: 0;\n                       background-color: #FFFFFF;\"\u003e\n                \u003ch2 style=\"text-align: center; margin: 0;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n                \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 2\" style=\"width: 100%;height: 100%;\"\u003e\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/table\u003e\n\u003c\/div\u003e\n          \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e \n \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV20003\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eU.S. Solid\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eUS Plug\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eSS304\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e6 - 8 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eAC 110V\/220V\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e5 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e6 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e0℃-90 ℃\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e80,000 to 100,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eFull\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\/G\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eNormally Closed\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003e-10℃- 40 ℃\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 16px; border: 0px; background-color: #FFFFFF;\"\u003eIP65\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/CE.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP65 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYES. The motorized ball valve is made of lead-free stainless steel and is NSF\/ANSI\/CAN 61 certified.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n    \u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP65 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP65. The first digit 6 indicates complete dust - tightness. The second digit 5 means protection against water jets from any direction. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/valve%20model.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n \u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/Instruction%20Manual-JFMSV2000x.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n    \u003c\/div\u003e\n    \u003cdiv class=\"mobile-only\"\u003e\n        \u003c!--  --\u003e\n        \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/coverimage.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n        \u003cp style=\"font-size: 22px; text-align: left; margin-top:0px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eINTRODUCTION\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; line-height:26px; margin-bottom:0px; margin-left: 0px;margin-right: 0px; margin-top: 0px; color: black; font-family: Arial;\"\u003eMotorized ball valves present an energy-efficient substitute for solenoid valves, particularly when it comes to prolonged positioning. They primarily consume power during the processes of opening and closing, and the energy consumption is negligible once they are fully opened. This characteristic enables a permanent connection, eliminating the risks of overheating or burnout.\u003c\/p\u003e\n            \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/1-SS.png\" style=\"flex: 1; margin: 0px; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-bottom:10px; margin-top:20px; color: black;\"\u003e\u003cstrong\u003eAPPLICATION\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/application.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eOPERATION PERFORMANCE\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n    \u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eAFTER WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif1.gif\" alt=\"GIF 1\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n    \u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eDISCONNECT THE WIRING\u003c\/strong\u003e\u003c\/h2\u003e\n    \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/gif2.gif\" alt=\"GIF 2\" style=\"width: 100%; display: block; margin: 0; padding: 0;\"\u003e\n\u003c\/div\u003e\n      \u003cp style=\"font-size: 16px; text-align: left; margin-bottom:10px; margin-top:20px;color: black;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n       \u003cdiv style=\"width: 100%; overflow-x: auto;\"\u003e\n        \u003ctable style=\"border-collapse: collapse; border: 0px; width: 100%; font-family: Arial; overflow-x: auto; background-color: #FFFFFF;\"\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eModel\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eUSS-MSV20003\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBrand\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eU.S. Solid\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eSize\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1\"\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWiring Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eUS Plug\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eValve Material\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eSS304\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBall Seal\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003ePTFE\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating Time\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e6 - 8 Seconds\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eWorking Voltage\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eAC 110V\/220V\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Power\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e5 W\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Torque\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e6 N m\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eMax Medium Pressure\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e1.0 Mpa\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eTemperature Range for Flow Medium\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e0℃-90 ℃\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eLife Expectancy\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e80,000 to 100,000 Cycles\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eBore Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eFull\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"border-bottom: 1px dashed black;\"\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eThread Type\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNPT\/G\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eOperating State\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eNormally Closed\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eAmbient Temperature Range\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003e-10℃- 40 ℃\u003c\/td\u003e\n                \u003cth style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #f0f0f0; color: black;\"\u003eEnclosure Rating\u003c\/th\u003e\n                \u003ctd style=\"width: 100%; text-align: left; padding: 5px; font-size: 14px; border: 0px; background-color: #FFFFFF;\"\u003eIP65\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCE CERTIFIED QUALITY \u0026amp; SAFETY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/CE.jpg\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n       \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1. What is the Waterproof Rating of this valve?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe motor's housing is rated at IP65 for ingress protection. If permanently installed outdoors, it is recommended to place it under a shelter or in a protective box to prevent prolonged exposure to rain.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2. What is the difference between N.C. (Normally Closed) and N.O. (Normally Open) ?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a N.C. valve, it's closed without power and opens when energized. Conversely, in a N.O. valve, it's open without power and closes when energized, blocking fluid or gas flow.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.What is the difference between Full Port and Standard Port?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eIn a full port valve, the internal diameter of the valve is the same as the pipe it's connected to. In a standard port valve, the internal diameter of the valve is smaller than the pipe size.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.Can this be used for Drinking Water?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYES. The motorized ball valve is made of lead-free stainless steel and is NSF\/ANSI\/CAN 61 certified.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.For auto return valves, what is the minimum On-Time required for electrical storage to enable closing when power off?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eTo ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e6.Can this valve be used for propane?\u003c\/b\u003e\u003c\/p\u003e\n        \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eYes, our motorized ball valves are suitable for use with propane.\u003c\/p\u003e\n    \u003c\/div\u003e\n       \u003cdiv style=\"flex: 1; padding: 0px; font-family: Arial;line-height: 26px;\"\u003e\n                \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px;margin-bottom:10px;line-height: 26px;color: black;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e\u003c\/p\u003e\n                 \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e1.\u003c\/b\u003e For 2-wire reverse polarity and 3-wire models, the valve is de-energized when fully open or closed. Other models may use a negligible amount of power when fully open, and the 5-wire model uses energy when closed to keep indicator lights operational. Refer to the specifications sheet for detailed information.\u003c\/p\u003e\n                \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e2.\u003c\/b\u003eThe valves depicted in this sheet are not designed to be operated manually. Attempting to manually open or close the valve may result in damage to the valve or injury.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e3.\u003c\/b\u003eOnly Auto Return Models will return to the closed position in the event of a power outage. All other models will remain in their current position. If this is a concern, consider purchasing an Auto-Return Model.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e4.\u003c\/b\u003eWhile the motorized ball valves have an IP65 rating, making them resistant to water spray, it is recommended to enclose the valve in a protective housing if permanently installed outdoors to ensure long-term durability.\u003c\/p\u003e\n               \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003e5.\u003c\/b\u003eThese valves are designed with power-limiting features, allowing them to be powered continuously without risk of overheating. However, always ensure proper installation and adherence to manufacturer guidelines to maintain safe operation.\u003c\/p\u003e\n            \u003c\/div\u003e\n            \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eValve Attributes\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eOperating States:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Closed: The valve is closed when power is off and opens when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eNormally Open: The valve is open when power is off and closes when power is on.\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePort Types:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eFull Port: It has a wide internal passage, resulting in low water - flow resistance.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eStandard Port: Meets regular usage requirements.\u003c\/p\u003e \n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003eIngress - Protection Rating:\u003c\/b\u003e\u003c\/p\u003e\n     \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eThe valves have an ingress - protection rating of IP65. The first digit 6 indicates complete dust - tightness. The second digit 5 means protection against water jets from any direction. They are suitable for a variety of complex environments, effectively resisting the intrusion of dust and water to ensure reliable operation.\u003c\/p\u003e \n     \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/valve%20model.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n             \u003cp style=\"font-size: 22px; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eWIRING SCHEMATICS\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/wiring-2.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n\u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003e\u003cb\u003ePlease note:\u003c\/b\u003e To ensure automatic reset functionality when the power is disconnected, it is essential to power the device for approximately one minute to charge the capacitor in 2-wire auto return motorized ball valves.\u003c\/p\u003e\n\u003cp style=\"font-size: 22px; font-family: Arial; text-align: left; margin-top:20px; margin-bottom:10px;color: black;\"\u003e\u003cstrong\u003eCHEMICAL RESISTANCE CHART FOR BALL VALVE SEAL MATERIALS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"http:\/\/file.ussolid.com\/content\/Detailed%20Page\/JFMSV\/Material-APP.png\" style=\"flex: 1; border: 0px; max-width: 100%;\" alt=\"\"\u003e\n    \u003cdiv style=\"text-align: left;\"\u003e\n  \u003cp style=\"font-size: 16px; margin-top:5px;margin-bottom:5px;line-height: 26px;color: black\"\u003eDownload user manual\u003ca href=\"http:\/\/file.ussolid.com\/content\/JFMSV\/Instruction%20Manual-JFMSV2000x.pdf\" target=\"_blank\"\u003e here\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n    \u003cscript\u003e\n\n        \/\/ (User Agent)\n        const isMobile = window.matchMedia(\"only screen and (max-width: 600px)\").matches;\n        const desktopContent = document.querySelector('.desktop-only');\n        const mobileContent = document.querySelector('.mobile-only');\n\n        if (isMobile) {\n            \/\/ \n            console.log('');\n            \/\/ ，\n            desktopContent.style.display = 'none';\n            mobileContent.style.display = 'block';\n        } else {\n            \/\/ \n            console.log('');            \n            \/\/ ，\n            desktopContent.style.display = 'block';\n            mobileContent.style.display = 'none';\n        }\n    \u003c\/script\u003e\n\n\n\n\u003c\/body\u003e","brand":"U.S. Solid","offers":[{"title":"110V AC \/ NPT","offer_id":46918491865343,"sku":"JFMSV20003","price":75.39,"currency_code":"USD","in_stock":true},{"title":"220V AC \/ G","offer_id":46918491898111,"sku":"JFMSV20003-G","price":72.79,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/8113\/7151\/files\/714q8NvKoEL._AC_SL1500.jpg?v=1735031230","url":"https:\/\/ussolid.com\/products\/us-solid-1-motorized-ball-valve-110220v-ac-stainless-steel-auto-return-normally-closed-with-plug-nsf-certified","provider":"U.S. Solid","version":"1.0","type":"link"}