Introduction
Featuring an exceptionally low minimum flow rate of just 0.764 nL/min, this U.S.Solid single-channel syringe pump is designed for accurate liquid delivery and withdrawal in laboratory environments. Supporting syringe sizes from 10 μL to 100 mL, the pump delivers an exceptionally wide flow range while maintaining precise control over volume and speed. Equipped with five operating modes, users can perform infusion, withdraw, withdraw-then-infusion, infusion-then-withdraw, and cyclic infuse/withdraw operation. With a rated linear force of 180 N, this syringe pump provides stable and dependable operation across a broad range of laboratory fluid transfer applications.
Features

More Details
- Delivers flow rates from 0.764 nL/min to 88.25 mL/min for precise micro-volume and general laboratory fluid handling.
- Supports five operating modes, including infuse, withdraw, withdraw-then-infuse, infuse-then-withdraw, and cyclic infuse/withdraw operation.
- Achieves high-precision liquid delivery with 0.156 μm stroke resolution and up to ±0.5% accuracy.
Packing List
Syringe Pump *1, Power Cable *1, Syringe *2.
Technical Data
↔️ Scroll left or right to view full details
| SKU | JFSP00001 | Model | USS-SP00001 |
|---|---|---|---|
| Pump Type | Single-Channel Infuse/Withdraw Syringe Pump | Channels | 1 |
| Flow Rate Range | 0.764 nL/min - 88.25 mL/min | Compatible Syringe Size | 10 μL - 100 mL |
| Operating Modes | Infuse, Withdraw, Withdraw-then-Infuse, Infuse-then-Withdraw, Cyclic infuse/withdraw operation | Maximum Stroke | 140 mm |
| Stroke Resolution | 0.156 μm | Linear Speed | 7.94 μm/min - 79.4 mm/min |
| Display | LCD Screen | Accuracy | Error ≤±0.5% (when the stroke is at least 30% of the maximum stroke) |
| Linear Force | 180 N | Communication Interface | RS485 |
| Calibration Function | Supported | Memory Function | Power-Off Memory |
| Power Supply | AC 90-260V, 30W | Net Weight | 3 kg |
| Dimensions | 265 × 154 × 144 mm | Operating Temperature | 0°C - 40°C |
| Operating Humidity | <80% RH | Syringe Selection | Built-in Syringe List & Direct Inner Diameter Input |
FAQ
1. Can I use syringes from brands that are not listed in the pump's built-in library?
Yes. The pump includes a built-in syringe list and also supports direct syringe inner diameter input, allowing users to work with compatible custom syringes.
2. What happens if the syringe becomes blocked during operation?
If a blockage is detected, the pump automatically stops and displays a "Stall" warning to protect the system. After the issue is resolved, the warning can be cleared and normal operation resumed.
3. Can this syringe pump be calibrated for better accuracy?
Yes. The pump supports calibration, helping improve dispensing accuracy for laboratory applications.
4. Will the pump save settings after power-off?
Yes. The pump includes a power-off memory function, allowing it to retain operating parameters after shutdown or power interruption.
5. Can this syringe pump be used for clinical or medical infusion?
No. This syringe pump is intended for laboratory research use only and is not suitable for clinical applications.