U.S. Solid

500 W 2-in-1 Ultrasonic Sonicator Cell Disruptor, Upgraded Touch Screen & Electric Lift, 50-500mL

500 W 2-in-1 Ultrasonic Sonicator Cell Disruptor, Upgraded Touch Screen & Electric Lift, 50-500mL

SKU-koodi: Product SKU: JFFX00014

200 varastossa

Normaalihinta $1,129.99 USD
Normaalihinta Alennushinta $1,129.99 USD
Alennusmyynti Loppuunmyyty
Toimituskulut lasketaan kassalla.

Estimated Shipping Widget will be displayed here!

Näytä kaikki tiedot

INTRODUCTION

Ultrasonic homogenizer for use in a laboratory for the purposes of mixing, emulsifying, homogenizing, disrupting cells, and reducing particle size in a sample.LCD Digital display, 99 hours total working time, variable output for pulsation, temperature indicator to prevent overheating, easy to use programming for optimal efficiency, automatic amplitude control, sound abating chamber to reduce cavitation noise, Output Power of 0-100% depending upon needs.

FEATURES

APPLICATIONS

OPERATION PERFORMANCE

EMULSIFICATION

GIF 1

DISPERSION

GIF 2

SPECIFICATIONS

Model USS-FX00014 Frequency range 19-25 kHz (Real-time frequency display)
Total working time 1s – 99hours with pause function Output Power 500 W(0%-100% continuously adjustable)
Power Regulation 1%-100%, 1% increments Processing Volume 50-500ml
Temperature Setting 0-300°C,1°C increments Number of Users 99
Diameter of Probe Φ6 mm Working Mode Pulse, Time, and Continuous

FAQ

1. Can ultrasonic output be started when the probe tip is exposed in the air?

No. Ultrasonic output should never be started when the probe tip is exposed in the air.

2. Does the apparatus need an industrial frequency transformer for the Power Regulation?

No. The apparatus adopts switching Power Regulation without industrial frequency transformer. Do not touch randomly after opening the generator housing to avoid electroshock.

3.Does the apparatus need to warm up before use?

No. The apparatus does not need to warm up and should be grounded well when in use.

4.In what kind of environment can the apparatus be used?

It should be used in the environment free from moisture, sunshine and corrosive gases.

5.How should the correct use regarding the platform and ultrasonic probe be ensured?

The platform should be tightly fixed to the rod, and the ultrasonic probe should be in liquid and not touch the walls of the sample vessel.

PACKING LIST

  1. Ultrasonic Host x1
  2. Ultrasonic Probe x1
  3. Lifting Table with Non-slip Mat x1
  4. Temperature Sensor x1
  5. Power Cord x1
  6. Cable x1
  7. Fuse x1

WARNING

1.The liquid temperature will increase rapidly due to the cavitation effect during crushing. Pay attention to the temperatures for different cells and consider adopting multiple short - time crushing (not longer than 5s each time) and ice bath cooling.

2.Multiple short - time operations (working time 1 - 2s and interval time 1 - 2s) have better effects than continuous long - time operations to avoid liquid heating.

3.The horn end will become rough due to cavitation corrosion after being used for a period of time. Use oil stone or rasp to smooth, otherwise it will influence the working effects.

4.For long - run operations with sample heating, gross sample heating can be minimized by nesting the sample vessel in an outer vessel containing ice, selecting longer interval (gap) times, or using a specially fabricated leptomastic ultrasonication vessel (available as an accessory).

5.If the liquid volume containing the sample is less than 5 ml, choose an ultrasonic probe having a tip diameter of 2 or 3 mm, and ensure the depth and distance requirements are met.

OTHER MODELS

SKU USS-FX00016 USS-FX00014 USS-FX00019 USS-FX00020 USS-FX00021
Temperature Sensor 0–300℃ 0-300℃ 0-300℃ 0-300℃ 0-300℃
Pulser Closed cycle/open cycle: 1 second to 99 minutes select setting Closed cycle/open cycle: 1 second to 99 minutes select setting Closed cycle/open cycle: 1 second to 99 minutes select setting Closed cycle/open cycle: 1 second to 99 minutes select setting Closed cycle/open cycle: 1 second to 99 minutes select setting
Timer 1 s - 99 hours, can be suspended 1 s - 99 hours, can be suspended 1 s - 99 hours, can be suspended 1 s - 99 hours, can be suspended 1 s - 99 hours, can be suspended
Power Supply AC 220V AC 220V AC 220V AC 220V AC 110V/220V
Power Regulation 0-100% (1% each time) 0-100% (1% each time) 0-100% (1% each time) 0-100% (1% each time) 0-100% (1% each time)
Net Power 1000W 500W 1800W 2000W 3000W
Cable Length 150 cm 150 cm 150 cm 150 cm 150 cm
Frequency 20 kHz 20 kHz 20 kHz 20 kHz 20 kHz
Standard Probe Φ10mm Φ6mm Φ18mm Φ20mm Φ30mm
Standard Probe Sample Processing Capacity 0.1-1200mL 0.1-500ml 50-2200ml 50-3000ml 50-4500ml
Transducer Diameter 50mm 50mm 73mm 73mm 73mm
Transducer Length 150mm 150mm 170mm 170mm 170mm
Standard Horn Diameter 10mm 6mm 18mm 20mm 30mm
Standard Horn Length 118mm 118mm 139mm 139mm 139mm
Standard Horn Weight 80g 80g 400g 450g 450g

Download user manual here

INTRODUCTION

Ultrasonic homogenizer for use in a laboratory for the purposes of mixing, emulsifying, homogenizing, disrupting cells, and reducing particle size in a sample.LCD Digital display, 99 hours total working time, variable output for pulsation, temperature indicator to prevent overheating, easy to use programming for optimal efficiency, automatic amplitude control, sound abating chamber to reduce cavitation noise, Output Power of 0-100% depending upon needs.

FEATURES

APPLICATION

OPERATION PERFORMANCE

EMULSIFICATION

GIF 1

DISPERSION

GIF 2

SPECIFICATIONS

Model USS-FX00014 Frequency range 19-25 kHz (Real-time frequency display)
Total working time 1s – 99hours with pause function Output Power 500 W(0%-100% continuously adjustable)
Power Regulation 1%-100%, 1% increments Processing Volume 50-500ml
Temperature Setting 0-300°C,1°C increments Number of Users 99
Diameter of Probe Φ6 mm Working Mode Pulse, Time, and Continuous

FAQ

1. Can ultrasonic output be started when the probe tip is exposed in the air?

No. Ultrasonic output should never be started when the probe tip is exposed in the air.

2. Does the apparatus need an industrial frequency transformer for the Power Regulation?

No. The apparatus adopts switching Power Regulation without industrial frequency transformer. Do not touch randomly after opening the generator housing to avoid electroshock.

3.Does the apparatus need to warm up before use?

No. The apparatus does not need to warm up and should be grounded well when in use.

4.In what kind of environment can the apparatus be used?

It should be used in the environment free from moisture, sunshine and corrosive gases.

5.How should the correct use regarding the platform and ultrasonic probe be ensured?

The platform should be tightly fixed to the rod, and the ultrasonic probe should be in liquid and not touch the walls of the sample vessel.

PACKING LIST:

  1. Ultrasonic Host x1
  2. Ultrasonic Probe x1
  3. Lifting Table with Non-slip Mat x1
  4. Temperature Sensor x1
  5. Power Cord x1
  6. Cable x1
  7. Fuse x1
  8. User manual x1
Product Image

WARNING

1.The liquid temperature will increase rapidly due to the cavitation effect during crushing. Pay attention to the temperatures for different cells and consider adopting multiple short - time crushing (not longer than 5s each time) and ice bath cooling.

2.Multiple short - time operations (working time 1 - 2s and interval time 1 - 2s) have better effects than continuous long - time operations to avoid liquid heating.

3.The horn end will become rough due to cavitation corrosion after being used for a period of time. Use oil stone or rasp to smooth, otherwise it will influence the working effects.

4.For long - run operations with sample heating, gross sample heating can be minimized by nesting the sample vessel in an outer vessel containing ice, selecting longer interval (gap) times, or using a specially fabricated leptomastic ultrasonication vessel (available as an accessory).

5.If the liquid volume containing the sample is less than 5 ml, choose an ultrasonic probe having a tip diameter of 2 or 3 mm, and ensure the depth and distance requirements are met.

OTHER MODELS

SKU USS-FX00016 USS-FX00014 USS-FX00019 USS-FX00020 USS-FX00021
Temperature Sensor 0–300℃ 0-300℃ 0-300℃ 0-300℃ 0-300℃
Pulser Closed cycle/open cycle: 1 second to 99 minutes select setting Closed cycle/open cycle: 1 second to 99 minutes select setting Closed cycle/open cycle: 1 second to 99 minutes select setting Closed cycle/open cycle: 1 second to 99 minutes select setting Closed cycle/open cycle: 1 second to 99 minutes select setting
Timer 1 s - 99 hours, can be suspended 1 s - 99 hours, can be suspended 1 s - 99 hours, can be suspended 1 s - 99 hours, can be suspended 1 s - 99 hours, can be suspended
Power Supply AC 220V AC 220V AC 220V AC 220V AC 110V/220V
Power Regulation 0-100% (1% each time) 0-100% (1% each time) 0-100% (1% each time) 0-100% (1% each time) 0-100% (1% each time)
Net Power 1000W 500W 1800W 2000W 3000W
Cable Length 150 cm 150 cm 150 cm 150 cm 150 cm
Frequency 20 kHz 20 kHz 20 kHz 20 kHz 20 kHz
Standard Probe Φ10mm Φ6mm Φ18mm Φ20mm Φ30mm
Standard Probe Sample Processing Capacity 0.1-1200mL 0.1-500ml 50-2200ml 50-3000ml 50-4500ml
Transducer Diameter 50mm 50mm 73mm 73mm 73mm
Transducer Length 150mm 150mm 170mm 170mm 170mm
Standard Horn Diameter 10mm 6mm 18mm 20mm 30mm
Standard Horn Length 118mm 118mm 139mm 139mm 139mm
Standard Horn Weight 80g 80g 400g 450g 450g

Download user manual here