Skip to product information
1 of 8

U.S. Solid

0.1mg Analytical Balance - Automatic Internal Calibration Precision Lab Balance, 120g x 0.0001g , Electromagnetic Force Sensor, RS232

0.1mg Analytical Balance - Automatic Internal Calibration Precision Lab Balance, 120g x 0.0001g , Electromagnetic Force Sensor, RS232

SKU: Product SKU: JFDBS00048

Low stock: 7 left

Regular price $557.00 USD
Regular price Sale price $557.00 USD
Sale Sold out
Shipping calculated at checkout.
View full details
Responsive Page with Multiple Modules Desktop Image 1 Desktop Image 2

Introduction

The USS-DBS48 Analytical Balance is equipped with an advanced electromagnetic force sensor, delivering exceptional accuracy of 0.0001 g—far superior to traditional strain gauge sensors. For applications requiring higher capacity and a readability of 0.001 g, the USS-DBS89 series is a more suitable choice.
The USS-DBS48 also offers percentage weighing and counting functions, along with adjustable stability and display speed settings, ensuring both efficiency and precision in your measurements. Additionally, it supports four weighing units: grams (g), milligrams (mg), carats (ct), and ounces (oz), providing the flexibility needed for a wide range of laboratory tasks.

Applications

Desktop Image 1 Desktop Image 2

Features

  • Readability: 0.0001g (0.1mg) with electromagnetic force sensor.
  • Enhanced Capacity: 0.001g-120g
  • Stabilization Time: ≤3 seconds
  • Internal Calibration
  • Four Weighing Units Conversion: g,mg,ct,oz
  • RS232 Interface: Enables connection to a printer or a computer for data transfer.
  • Overload protection, piece counting

More Details

Desktop Image 1 Desktop Image 2

User Manual

To learn how to install, calibrate, set up, and use this product, please refer to the user manual or watch the tutorial videos.

Packing List

Balance Main Body Power Cable
Weighing Pan Instruction Manual
Quality Certification Calibration Weight (100g)

*To view the full table on mobile, please swipe left or right on the screen.

Technical Data

Model USS-DBS48 Working Temperature 63.5℉ - 72.5℉
Weighing Sensor Electromagnetic Force Stabilization Time ≤3s
Calibration Internal calibration Windshield Yes
Capacity 0.001g-120g Units g,mg,ct,oz
Readability 0.0001g(0.1mg) Interface RS232
Repeatability ±0.0002g Power AC 110V
Linearity ±0.0003g Packaging Dimensions 20.87"x14.37"x20.87"
Pan Size Φ80 mm Gross Weight 19.84 lbs
Calibration Weight 100g*1 Number of Displays 1

*To view the full table on mobile, please swipe left or right on the screen.

Precautions

  • Leveling the Balance: Accurate horizontal positioning necessary for repeatable measurementsand exact results. Adjust the leveling feet of the analytical balance until the air bubbleinthe indicator is centered.
  • Warm-Up Requirement: For accurate results, the balance must warm up for at least 30 minutes after being powered on or after a power outage longer than 30 minutes, to reach the proper operating temperature before calibration or use.(For warm-up time details, refer to the user manual or contact support.)
  • Stability: Place the balance on a stable, vibration-free surface, away from drafts and electromagnetic interference. It's important to note that high-precision balances are more susceptible to environmental factors, which can affect reading stability.
  • Calibration: Calibrate the balance if it is moved (even within the same room), when ambient conditions change, and before each use. If pressing the "CAL" button has no effect, ensure you are pressing and holding it. For most models, calibration requires a long press rather than a quick tap.(Refer to the manual for specific instructions).

Troubleshooting

Problem 1: Display remains off after switching on.

Possible causes: Power cord is not connected/ Power line fuse blown/ Power supply interrupted/ Instrument faulty

Problem 2: Display does not change when loading samples.

Possible causes: The sample pan/pan holder is not installed correctly.

Problem 3: Weight display is constantly changing or unstable.

Possible causes: The sample pan is in contact with the draft shield or heating chamber/ Air movement/ Test bench vibration/ Electromagnetic field interference

All Options

Units Readability Model Capacity Calibration Weight Pan Size Repeatability Linearity Interface Power Supply Stabilization Time Calibration
4 types 0.0001g USS-DBS48 0.001g-120g 100g*1 Φ80mm ±0.0002g ±0.0003g RS232 AC 110V ≤3s Internal calibration
USS-DBS47 0.001g-220g 200g*1
0.001g USS-DBS89-500G 0.01g-500g ±0.002g ±0.003g
USS-DBS89-600G 0.01g-600g
USS-DBS89-1000G 0.01g-1000g 500g*1 Φ100mm
USS-DBS89-1200G 0.01g-1200g
* 4 Weighing Units Conversion: g,mg,ct,oz