Introduction
The USS-DBS81 Precision Balance series offers high accuracy and reliability, with a precision of 0.001g. Designed for ease of use and quick response, it ensures precise measurement of sample weights.
Featuring dual display screens (front and rear), this balance is versatile, suitable for both standard applications and specialized scenarios where single-screen balances fall short.
The advantages of this balance are its high cost-performance ratio, excellent quality, and fast response. We also offer the basic USS-DBS87 series, which is essentially the same as the DBS81 but features a single display screen.
Applications


Features
- Readability: 0.001g (1mg), enabled by a strain gauge load cell
- Capacity: 0.01g - 310g
- Stabilization Time: Within 3 seconds
- Dual Displays: Enhanced readability and multi-angle viewing with front and back displays.
- External Calibration: Manual calibration with weights
- Four Weighing Units Conversion: g, gn, oz, ct
- RS232 Interface
- Quality Assured: UL-certified power cord for guaranteed performance.
- Counting Function
- Overload Warning Function
More Details


User Manual
For instructions on how to install, calibrate, set up, and use the product, please refer to the user manual or watch the tutorial video.
Packing List
① | Balance Main Body | ⑤ | Calibration Weight (200g) | ||
② | Weighing Pan | ⑥ | Instruction Manual | ||
③ | Draft Shield | ⑦ | Quality Certification | ||
④ | Power Cable |
*To view the full table on mobile, please swipe left or right on the screen.
Technical Data
Model | USS-DBS81-310G | Calibration Weight | 200g | ||
Stabilization Time | ≤3 s | Weighing Sensor | Strain gauge load cell | ||
Calibration | External calibration | Number of Displays | 2 | ||
Capacity | 0.01g - 310g | Units | g, gn, oz, ct | ||
Readability | 0.001g (1mg) | Interface | RS232 | ||
Repeatability | ±0.002g | Power | 110V, 60Hz, AC | ||
Linearity | ±0.003g | Packaging Dimensions | 14.25"x14.17"x10.63" | ||
Pan Size | Φ90 mm | Gross Weight | 7.45 lbs | ||
Working Temperature | 59°F- 95°F | Windshield | Yes |
*To view the full table on mobile, please swipe left or right on the screen.
Precautions
- Leveling the Balance: Accurate horizontal positioning necessary for repeatable measurementsand exact results. Adjust the leveling feet of the analytical balance until the air bubbleinthe indicator is centered.
- Warm-Up Requirement: For accurate results, the balance must warm up for at least 30 minutes after being powered on or after a power outage longer than 30 minutes, to reach the proper operating temperature before calibration or use.(For warm-up time details, refer to the user manual or contact support.)
- Stability: Place the balance on a stable, vibration-free surface, away from drafts and electromagnetic interference. It's important to note that high-precision balances are more susceptible to environmental factors, which can affect reading stability.
- Calibration: Calibrate the balance if it is moved (even within the same room), when ambient conditions change, and before each use. If pressing the "CAL" button has no effect, ensure you are pressing and holding it. For most models, calibration requires a long press rather than a quick tap.(Refer to the manual for specific instructions).
Troubleshooting
Problem 1: Display remains off after switching on.
Possible causes: Power cord is not connected/ Power line fuse blown/ Power supply interrupted/ Instrument faulty
Problem 2: Display does not change when loading samples.
Possible causes: The sample pan/pan holder is not installed correctly.
Problem 3: Weight display is constantly changing or unstable.
Possible causes: The sample pan is in contact with the draft shield or heating chamber/ Air movement/ Test bench vibration/ Electromagnetic field interference
All Options
Readability | Units | Model | Capacity | Display Qty | Calibration | Calibration Weight | Stabilization Time | Power Supply | Linearity Error | Repeatability Error | Pan | Interface |
0.001g | 4 types | USS-DBS81-110G | 0.01g - 110g | 2 | External calibration | 100g*1 | ≤3 s | 110V | ± 0.002g | ± 0.003g | Φ90mm | RS-232 |
USS-DBS87-110G | 1 | Internal calibration | ||||||||||
USS-DBS81-210G | 0.01g - 210g | 2 | Enternal calibration | 200g*1 | ||||||||
USS-DBS87-210G | 1 | Internal calibration | ||||||||||
USS-DBS81-310G | 0.01g - 310g | 2 | Enternal calibration | 200g*1 | ||||||||
USS-DBS87-310G | 1 | Internal calibration | ||||||||||
* 4 Weighing Units Conversion: g, gn, oz, ct |