U.S. Solid 100 x 0.001g Analytical Balance, 1 mg Digital Precision Balance Lab Scale

U.S. Solid 100 x 0.001g Analytical Balance, 1 mg Digital Precision Balance Lab Scale

SKU: Product SKU: JFDBS00057-100G

Low stock: 8 left

Regular price $148.00 USD
Regular price Sale price $148.00 USD
Sale Sold out
Shipping calculated at checkout.
 More payment options
View full details
Responsive Page with Multiple Modules Desktop Image 1 Desktop Image 2

Introduction

The USS-DBS57 precision balance series offers high accuracy and reliability with a precision of 0.001g. Designed for ease of use and quick response, it ensures precise measurement of sample weights. This balance features a single display screen and an RS232 interface for essential weighing tasks.
This balance offers a high cost-performance ratio, excellent quality, and fast response. It's ideal for users who require accurate measurements without the need for dual displays or advanced connectivity options. For those who require these additional features, the USS-DBS58 is an excellent alternative.

Applications

Desktop Image 1 Desktop Image 2

Features

  • Readability: 0.001g (1mg) with strain gauge load cell
  • Capacity:20mg-100g
  • Stabilization Time: ≤2 seconds
  • External Calibration: Manual calibration with weights
  • 19 Weighing Units Conversion: g, kg, ct, T, TAR, dr, PKT, GN, TMR, gsm, tlJ, mo, dwt, oz, lb, tlT, ozt, tlH, %.(In addition, 16 different unit packages are lockable, e.g., you can lock g,t,ct,oz,lb and hide other uncommon units.)
  • RS232 Interface
  • 3 Print Modes: Continuous print, key print and command print
  • Both AC/ DC power supply: AC 100V-240V power or 4x1.5V battery(not included)
  • Primary Functions: Qverload protection, checking weighing, piece counting function, percentage function, tare function, fault display

More Details

Desktop Image 1 Desktop Image 2

User Manual

To learn how to install, calibrate, set up, and use this product, please refer to the user manual.

Packing List

Balance Main Body Power Cable
Weighing Pan Instruction Manual
Calibration Weight (50g)

*To view the full table on mobile, please swipe left or right on the screen.

Technical Data

Model USS-DBS57-1 Working Temperature 41℉ - 95℉
Weighing Sensor Strain gauge load cell Stabilization Time ≤2s
Calibration External calibration Calibration Weight 50g*1
Capacity 20mg-100g Units g, kg, ct, T, TAR, dr, PKT, GN, TMR, gsm, tlJ, mo, dwt, oz, lb, tlT, ozt, tlH, %
Readability 0.001g(1mg) Interface RS232
Repeatability ±0.002g Power AC 100V-240V/4x1.5V battery(not included)
Linearity ±0.003g Packaging Dimensions 14.76"x10.04"x13.78"
Pan Size Φ90 mm Gross Weight 7.83 lbs
Number of Displays 1 Windshield Yes

*To view the full table on mobile, please swipe left or right on the screen.

Precautions

  • Leveling the Balance: Accurate horizontal positioning necessary for repeatable measurementsand exact results. Adjust the leveling feet of the analytical balance until the air bubbleinthe indicator is centered.
  • Warm-Up Requirement: For accurate results, the balance must warm up for at least 30 minutes after being powered on or after a power outage longer than 30 minutes, to reach the proper operating temperature before calibration or use.(For warm-up time details, refer to the user manual or contact support.)
  • Stability: Place the balance on a stable, vibration-free surface, away from drafts and electromagnetic interference. It's important to note that high-precision balances are more susceptible to environmental factors, which can affect reading stability.
  • Calibration: Calibrate the balance if it is moved (even within the same room), when ambient conditions change, and before each use. If pressing the "CAL" button has no effect, ensure you are pressing and holding it. For most models, calibration requires a long press rather than a quick tap.(Refer to the manual for specific instructions).

Troubleshooting

Problem 1: Display remains off after switching on.

Possible causes: Power cord is not connected/ Power line fuse blown/ Power supply interrupted/ Instrument faulty

Problem 2: Display does not change when loading samples.

Possible causes: The sample pan/pan holder is not installed correctly.

Problem 3: Weight display is constantly changing or unstable.

Possible causes: The sample pan is in contact with the draft shield or heating chamber/ Air movement/ Test bench vibration/ Electromagnetic field interference

All Options

Readability Capacity Model Display Qty Interface Calibration Weight Calibration Stabilization Time Units Power Supply Linearity Repeatability Pan
0.001g 20mg-100g USS-DBS57-1 1 RS232 50g*1 EXternal calibration ≤2s 19 types AC/DC ±0.003g ±0.002g Φ90mm
USS-DBS58-1 2 RS232 and USB
20mg-200g USS-DBS57-2 1 RS232 100g*1
USS-DBS58-2 2 RS232 and USB
20mg-300g USS-DBS57-3 1 RS232 200g*1
USS-DBS58-3 2 RS232 and USB
20mg-500g USS-DBS57-5 1 RS232 500g*1
USS-DBS58-5 2 RS232 and USB
* 19 Weighing Units Conversion: g, kg, ct, T, TAR, dr, PKT, GN, TMR, gsm, tlJ, mo, dwt, oz, lb, tlT, ozt, tlH, %