Introduction
The USS-DBS86-5 precision balance, with a capacity of up to 5100g and a readability of 0.1g. The strain gauge weighing sensor ensures reliable results, while the backlit LCD display provides clear readings. This balance features a large rectangular weighing pan to accommodate larger samples. Please note that this model does not include a draft shield. It is well-suited for applications requiring a degree of precision, but it may not be the best choice for highly specialized applications demanding the highest accuracy.
Applications


Features
- Readability: 0.1g with strain gauge load cell
- Capacity: 1g-5100g
- Stabilization Time: ≤3 seconds
- External Calibration: Manual calibration with weights
- 4 Weighing Units Conversion: g, gn, oz, ct
- Large size stainless steel rectangular pan: 160x160mm
- RS232 Interface: Enables connection to a printer or a computer for data transfer.
- Built-in Applications: Piece counting function, tare function, fault display and etc.
- Power Supply: AC/Rechargeable Battery
More Details


User Manual
To learn how to install, calibrate, set up, and use this product, please refer to the user manual or watch the tutorial videos.
Packing List
① | Balance Main Body | ② | Power Cable | ||
③ | Instruction Manual | ④ | Quality Certification | ||
⑤ | Weighing Pan |
*To view the full table on mobile, please swipe left or right on the screen.
Technical Data
Model | USS-DBS86-5 | Working Temperature | 41℉-104℉ | ||
Display Qty | 1 | Windshield | No | ||
Weighing Sensor | Strain gauge load cell | Stabilization Time | ≤3s | ||
Calibration | External calibration | Calibration Weight | No | ||
Capacity | 1g-5100g | Units | g, gn, oz, ct | ||
Readability | 0.1g | Interface | RS232 | ||
Repeatability | ±0.2g | Power | AC110V | ||
Linearity | ±0.3g | Packaging Dimensions | 12.01"x9.33"x5.20" | ||
Pan Size | 160x160 mm | Gross Weight | 3.90 lbs |
*To view the full table on mobile, please swipe left or right on the screen.
Precautions
- Leveling the Balance: Accurate horizontal positioning necessary for repeatable measurementsand exact results. Adjust the leveling feet of the analytical balance until the air bubbleinthe indicator is centered.
- Warm-Up Requirement: For accurate results, the balance must warm up for at least 30 minutes after being powered on or after a power outage longer than 30 minutes, to reach the proper operating temperature before calibration or use.(For warm-up time details, refer to the user manual or contact support.)
- Stability: Place the balance on a stable, vibration-free surface, away from drafts and electromagnetic interference. It's important to note that high-precision balances are more susceptible to environmental factors, which can affect reading stability.
- Calibration: Calibrate the balance if it is moved (even within the same room), when ambient conditions change, and before each use. If pressing the "CAL" button has no effect, ensure you are pressing and holding it. For most models, calibration requires a long press rather than a quick tap.(Refer to the manual for specific instructions).
All Options
Readability | Model | Capacity | Display Qty | Pan Size | Wind Shield | Repeatability | Linearity | Power Supply | Interface | Stabilization Time | Calibration |
0.01g | USS-DBS82-1100G | 0.1g-1100g | 1 | Φ130mm | yes | ±0.02g | ±0.03g | AC | RS232 | ≤3s | external calibration |
USS-DBS82-2100G | 0.1g-2100g | ||||||||||
USS-DBS82-3100G | 0.1g-3100g | 2 | |||||||||
0.1g | USS-DBS86-3 | 1g-3100g | 1 | 160x160mm | no | ±0.2g | ±0.3g | ||||
USS-DBS86-5 | 1g-5100g | ||||||||||
USS-DBS86-6 | 1g-6100g | ||||||||||
* 4 Weighing Units Conversion: g, gn, oz, ct |