Introduction
The U.S. Solid USS-DBS88 High-Precision Analytical Balance boasts an expansive capacity that surpasses conventional 0.1 mg analytical balances. This balance is equipped with a state-of-the-art high-precision weighing transducer that ensures unparalleled stability compared to standard analytical balances. Moreover, it incorporates an internal calibration function, eliminating the necessity for manual weight calibration.
This analytical balance is designed to meet the demands of applications requiring both high precision and wide capacity. It also offers a wide range of functions, including formulation functions, GLP data output, animal weighing, percentage weighing, full capacity taring, and density determination - to name just a few.
While this balance excels in high-capacity weighing, if your needs prioritize ultra-high precision with a 0.01mg readability and a more compact capacity, consider the USS-DBS84 series.
Applications


Features
- Readability: 0.0001g (0.1mg) with electromagnetic force sensor.
- Capacity: 0.001g - 610g
- Stabilization Time: ≤4 seconds
- Automatic Internal Calibration
- Ten Weighing Units Conversion: g, mg, ct, oz, lb, dwt, ozt, gn, tl, mo
- RS232 Interface: Enables connection to a printer or a computer for data transfer.
- Multi languages: English, French, German, Italian, Spanish, Portuguese
- Universal Power: AC110-230V, 50/60Hz; DC12V 1A with 4 interchangeable plugs for worldwide use.
- Multifunction:Includes a variety of features, such as formulation, GLP data output, density determination, animal weighing, full capacity taring, percentage weighing, and piece counting, among many others.(The density determination kit is not included in the set.)
More Details


User Manual
To learn how to install, calibrate, set up, and use this product, please refer to the user manual.
Packing List
① | Balance Main Body | ② | Power Cable(with 4 interchangeable plugs) | ||
③ | Weighing Pan | ④ | Instruction Manual |
*To view the full table on mobile, please swipe left or right on the screen.
Technical Data
Model | USS-DBS88-610G | Working Temperature | 41℉ - 95℉ | ||
Weighing Sensor | Electromagnetic Force | Stabilization Time | ≤4s | ||
Calibration | Internal calibration | Windshield | Yes | ||
Capacity | 0.001g-610g | Units | g, mg, ct, oz, lb, dwt, ozt, gn, tl, mo | ||
Readability | 0.0001g(0.1mg) | Interface | RS232 | ||
Repeatability | ±0.00035g | Power | AC110-230V,50/60Hz; Out DC12V 1A | ||
Linearity | ±0.0005g | Packaging Dimensions | 20.08"x24.41"x15.75" | ||
Pan Size | Φ80 mm | Gross Weight | 18.19 lbs |
*To view the full table on mobile, please swipe left or right on the screen.
Precautions
- Leveling the Balance: Accurate horizontal positioning necessary for repeatable measurementsand exact results. Adjust the leveling feet of the analytical balance until the air bubbleinthe indicator is centered.
- Warm-Up Requirement: For accurate results, the balance must warm up for at least 30 minutes after being powered on or after a power outage longer than 30 minutes, to reach the proper operating temperature before calibration or use.(For warm-up time details, refer to the user manual or contact support.)
- Stability: Place the balance on a stable, vibration-free surface, away from drafts and electromagnetic interference. It's important to note that high-precision balances are more susceptible to environmental factors, which can affect reading stability.
- Calibration: Calibrate the balance if it is moved (even within the same room), when ambient conditions change, and before each use. If pressing the "CAL" button has no effect, ensure you are pressing and holding it. For most models, calibration requires a long press rather than a quick tap.(Refer to the manual for specific instructions).
Error Codes
DISPLAY | MEANING | SOLUTIONS | |||
ERR01 | Weight not stable after operation of tare | Protect the balance from air flows or from vibrations of the working table | |||
ERR02 | Impossible to start the calibration due to instability of the balance | Protect the balance from air flows or from vibrations of the working table. | |||
ERR03 | Calibration weight not correct or balance unstable | Calibrate with correct weight or protect the balance from environment disturbs. In models with internal calibration remove the screw in the left lower part of the balance (see user manual) | |||
ERR04 | Weight of samples for the piececounting function not adequate or unstable | Select a bigger number of samples or protect the balance from vibrations | |||
ERR05 | Impossible to print because of weight unstable | Protect the balance from environment disturbs | |||
ERR06 | Weight cannot get stable in density mode | Protect the balance from environment disturbs | |||
ERR07 | Weight cannot get stable in percentual weighing mode | Protect the balance from environment disturbs | |||
ERR08 | Anomaly on autocalibration motor | Contact service staff | |||
ERR09 | Weight cannot get stable in formulation mode | Protect the balance from environment disturbs | |||
ERR10 | Weight of component out of tollerance in formulation mode | Reduce quantity | |||
ERR F | Flash memory damaged | Ask assistance to authorized service staff | |||
UNLOAD | Weight loaded on the pan or pan not positioned properly | Remove the weight from the pan or position properly the pan and underpan. | |||
CAL But | The balance requires to be recalibrated | Unload weights, if any, on the pan, and press the CAL button | |||
![]() |
Over-range condition | Unload the weights loaded on the pan | |||
![]() |
Under-range condition | Place properly pan and underpan |
All Options
Units | Dual Capacity | Model | Readability | Capacity | Repeatability | Linearity | Stabilization Time | Pan Size | Power Supply | Interface | Calibration |
10 types | yes | USS-DBS84-62 | 0.00001g | 0.0001g-62g | ±0.03mg | ±0.08mg | ≤6s | Φ80mm | AC110-230V | RS232 | Internal calibration |
0.0001g | 0.001g-120g | ±0.1mg | ±0.2mg | ||||||||
USS-DBS84-82 | 0.00001g | 0.0001g-82g | ±0.05mg | ±0.1mg | |||||||
0.0001g | 0.001g-220g | ±0.1mg | ±0.2mg | ||||||||
no | USS-DBS88-310G | 0.0001g | 0.001g-310g | ±0.3mg | ±0.5mg | ≤4s | |||||
USS-DBS88-410G | 0.001g-410g | ±0.35mg | |||||||||
USS-DBS88-510G | 0.001g-510g | ||||||||||
USS-DBS88-610G | 0.001g-610g | ||||||||||
USS-DBS88-1100G | 0.001g-1100g | ||||||||||
* 10 Weighing Units Conversion: g, mg, ct, oz, lb, dwt, ozt, gn, tl, mo |