Introduction
The USS-DBS15 series delivers high accuracy with a precision of 0.001g, ensuring reliable and precise measurements for a variety of weighing tasks. Designed for ease of use and quick response, it features a clear single display screen and an RS232 interface for seamless data transfer. Ideal for laboratory and industrial applications, this balance combines performance and simplicity for efficient weighing operations.
Applications


Features
- Readability: 0.001g with strain gauge
- Capacity:20mg-500g
- Stabilization Time: ≤1.5 seconds
- External Calibration: Manual calibration with weights
- 5 Weighing Units Conversion: oz, ct, g, ozt, lb
- RS232 Interface: Enables connection to a printer or a computer for data transfer.
- Built-in Applications: Piece counting function, tare function, over load protection, memory for accumulated time and etc.
More Details


User Manual
To learn how to install, calibrate, set up, and use this product, please refer to the user manual.
Packing List
① | Balance Main Body | ② | Power Cable | ||
③ | Calibration Weight (500g) | ④ | Instruction Manual |
*To view the full table on mobile, please swipe left or right on the screen.
Technical Data
Model | USS-DBS15-5 | Working Temperature | 41℉-104℉ | ||
Weighing Sensor | Strain gauge | Stabilization Time | ≤1.5s | ||
Calibration | External calibration | Calibration Weight | 500g*1 | ||
Capacity | 20mg-300 g | Units | oz, ct, g, ozt, lb | ||
Readability | 0.001g | Interface | RS232 | ||
Repeatability | ±0.005g | Power | AC110-240V 50/60Hz | ||
Linearity | ±0.005g | Packaging Dimensions | 13.78"x10.63"x13.98" | ||
Pan Size | Φ90 mm | Gross Weight | 9.24 lbs | ||
Number of Displays | 1 | Windshield | Yes |
*To view the full table on mobile, please swipe left or right on the screen.
Precautions
- Leveling the Balance: Accurate horizontal positioning necessary for repeatable measurementsand exact results. Adjust the leveling feet of the analytical balance until the air bubbleinthe indicator is centered.
- Warm-Up Requirement: For accurate results, the balance must warm up for at least 30 minutes after being powered on or after a power outage longer than 30 minutes, to reach the proper operating temperature before calibration or use.(For warm-up time details, refer to the user manual or contact support.)
- Stability: Place the balance on a stable, vibration-free surface, away from drafts and electromagnetic interference. It's important to note that high-precision balances are more susceptible to environmental factors, which can affect reading stability.
- Calibration: Calibrate the balance if it is moved (even within the same room), when ambient conditions change, and before each use. If pressing the "CAL" button has no effect, ensure you are pressing and holding it. For most models, calibration requires a long press rather than a quick tap.(Refer to the manual for specific instructions).
Troubleshooting
Problem | Cause | Solution | |
Upper Line "![]() |
Over Load | Re-calibrate | |
Under Line "![]() |
Overload or load cell broken | Re-calibrate | |
Display shows "Err-1" | Too frequently turn on and off the balance | Turn off the balance, resume it after 3 seconds | |
Display shows "Err-2" | The balance is not stabilized | Recalibrate machine make sure balance is level, and make sure item being weighed is fully stable. |
*To view the full table on mobile, please swipe left or right on the screen.
All Options
Units | Readability | Model | Capacity | Calibration Weight | Repeatability | Linearity | Calibration | Interface | Stabilization Time | Pan Size | Power Supply |
5 types | 0.001g | USS-DBS15-1 | 20mg-100g | 50g*1 | ±0.002g | ±0.002g | External calibration | RS232 | ≤1.5s | Φ90mm | AC100-240V |
USS-DBS15-2 | 20mg-200g | 100g*1 | |||||||||
USS-DBS15-3 | 20mg-300g | 200g*1 | |||||||||
USS-DBS15-5 | 20mg-500g | 500g*1 | ±0.005g | ±0.005g | |||||||
* 5 Weighing Units Conversion: oz,ct,g,ozt,lb |