Skip to product information
1 of 3

U.S. Solid

High-Precision Lab Syringe Pump, 0.7 pL/min Ultra-Low Flow Rate, ±0.1% Accuracy, Touchscreen

High-Precision Lab Syringe Pump, 0.7 pL/min Ultra-Low Flow Rate, ±0.1% Accuracy, Touchscreen

SKU: Product SKU: JFSP00013

20 in stock

Regular price $2,149.00 USD
Regular price Sale price $2,149.00 USD
Sale Sold out
Shipping calculated at checkout.

Estimated Shipping Widget will be displayed here!

View full details

Introduction

Precision laboratory syringe pump designed for both infusion and withdrawal. Supports 0.5 μL–60 mL syringes with flow rates from 0.0007 nL/min (0.7 pL/min) to 109.1360 mL/min. With six operating modes, ≤±0.1% stroke control accuracy, a 5" touchscreen, syringe calibration, real-time flow adjustment, USB/RS485 communication, it provides flexible control for both standalone experiments and automated laboratory workflows. Suitable for microfluidics, biological research, chemistry, pharmaceutical research, micro-volume infusion, and automated liquid handling.

Applications

Pharmaceutical Research Pharmaceutical Research
Biological Laboratories Biological Laboratories
Micro-Volume Liquid Infusion Micro-Volume Liquid Infusion
Chemistry Chemistry
×

Features

More Details

Packing List

Syringe Pump *1, Power Cable *1, Syringe *2.

User Manual

For detailed information on installation, setup, and usage, please refer to the user manual.

Technical Data

SKU JFSP00013 Model USS-SP00013
Pump Type Single-Channel Smart Infuse/Withdraw Syringe Pump Channels 1
Linear Force 160 N Operating Modes Infuse, Withdraw, Withdraw-then-Infuse, Infuse-then-Withdraw, Cyclic infuse/withdraw operation, Multiple Infusion
Flow Rate Range 0.0007 nL/min - 109.1360 mL/min Compatible Syringe Size 0.5 μL - 60 mL
Maximum Stroke 150 mm Stepping Resolution 0.0625 μm/μstep
Linear Speed 0.08 μm/min - 160 mm/min Stroke-Control Accuracy Error ≤±0.1% (when the stroke is at least 30% of the maximum stroke)
Display 5-inch HD Touch Screen (800 × 480) Communication Interface RS485/USB Optional
Calibration Function Supported Syringe Selection Built-in & Custom Syringe Configuration
Power Supply AC 90-264V, 50/60 Hz Dimensions 256 × 190 × 146 mm

*To view the full table on mobile, please swipe left or right on the screen.

FAQ

1. What operating modes are available?

This syringe pump supports six operating modes: Infusion, Withdrawal, Infuse-then-Withdraw, Withdraw-then-Infuse, Continuous infuse/withdraw operation, and Multiple Infusion.

These modes allow the pump to handle simple dispensing, liquid withdrawal, bidirectional operation, continuous cycling, and repeated dosing workflows.

2. What flow rates can this syringe pump achieve?

The available flow range depends on the syringe inner diameter. Smaller syringes provide ultra-low flow rates for micro-volume applications, while larger syringes support higher flow rates.

The pump supports syringes from 0.5 μL to 60 mL. Use the reference values shown here to check whether your syringe and target flow rate are suitable.

Syringe Size Reference Flow Rate
0.5 μL 0.0007 nL/min - 0.0013 mL/min
5 μL 0.0074 nL/min - 0.0148 mL/min
100 μL 0.1334 nL/min - 0.2668 mL/min
1 mL 1.4060 nL/min - 2.8110 mL/min
5 mL 9.6620 nL/min - 19.3220 mL/min
10 mL 13.8940 nL/min - 27.7860 mL/min
30 mL 34.2870 nL/min - 68.5730 mL/min
60 mL 54.5680 nL/min - 109.1360 mL/min

3. What syringes are compatible with this pump?

The pump supports syringe capacities from 0.5 μL to 60 mL. Common syringe specifications are available in the built-in syringe library. If your syringe model is not included, you can manually enter the syringe inner diameter (ID), allowing the pump to calculate accurate flow rates.

4. Can infusion and withdrawal use different flow rates?

Yes. In Infuse-then-Withdraw and Withdraw-then-Infuse modes, the infusion and withdrawal speeds can be configured independently. The interval between direction changes can also be set.

5. Can the pump perform repeated dosing automatically?

Yes. Multiple Infusion mode allows you to set the volume of the repeated infusion step, the number of repetitions, and the interval between consecutive doses, making it suitable for repeated dispensing workflows.

6. Can the pump be controlled by a computer or external signal?

Yes. The pump supports USB and RS485 communication using Modbus RTU. External start/stop control is also available, and a footswitch interface is also provided.

7. How does the pump ensure reliable operation?

The pump features built-in calibration for improved dispensing accuracy, automatic Stall protection that stops operation if excessive resistance is detected, and power-off memory that retains operating parameters after a power interruption.

8. Is this pump suitable for my application?

This pump is suitable for laboratory applications including microfluidics, biological research, chemistry, pharmaceutical research, electrospinning, and other precision liquid-handling workflows.

If you are unsure, send us your syringe size or inner diameter, required flow rate, operating mode, and communication requirements. Our team can help confirm compatibility before ordering.

9. Is this syringe pump intended for medical or clinical use?

No. This product is intended exclusively for laboratory research and industrial fluid handling applications.

10. What warranty does this syringe pump include?

We offer a one-year quality warranty. See more about our return policy.

11. What is the difference between this syringe pump and USS-SP00008?

Both pumps offer the same accuracy. This model supports a lower minimum flow rate (0.7 pL/min), making it better for very low-volume liquid delivery, and has a larger touch screen (5-inch).

All Options

Explore Our Full Range of Syringe Pump Options

We offer a variety of models with different flow rates, channel numbers, accuracy, and linear force to meet your specific fluid transfer requirements.

VIEW MODEL SELECTION TABLE