The USS-DBS59-5 precision balance, with a capacity of up to 500g and a readability of 0.01g, is ideal for applications requiring a moderate level of precision. The strain gauge weighing sensor ensures reliable results, while the backlit LCD display provides clear readings.
This balance features a large rectangular weighing pan to accommodate larger samples. Please note that this model does not include a draft shield. It is well-suited for tasks like chemical experiments, pharmaceutical formulations, and food processing where a degree of precision is required, but it may not be the best choice for highly specialized applications demanding the highest accuracy.

Applications

Desktop Image 1 Desktop Image 2

Features

  • Readability: 0.01g with strain gauge
  • Capacity:0.1g-500g
  • Stabilization Time: ≤3 seconds
  • External Calibration: Manual calibration with weights
  • 10 Weighing Units Conversion: g, ct, oz, ozt, lb, TOL, dwt, MM, kg and %
  • Large size stainless steel rectangular pan: 150x180mm
  • Both AC/ DC power supply: AC 100V-240V power or 9V battery(battery not included)
  • Built-in Applications: parts counting, percentage function, tare function, fault display and etc.

More Details

Desktop Image 1 Desktop Image 2

User Manual

To learn how to install, calibrate, set up, and use this product, please refer to the user manual or watch the tutorial videos.

Packing List

Balance Main Body Power Cable
Weighing Pan Instruction Manual
Calibration Weight (200g)

*To view the full table on mobile, please swipe left or right on the screen.

Technical Data

Model USS-DBS59-5 Working Temperature 41℉ - 104℉
Weighing Sensor Strain gauge Stabilization Time ≤3s
Calibration External calibration Calibration Weight 200g*1
Capacity 0.1g-500g Units g, ct, oz, ozt, lb, TOL, dwt, MM, kg and %
Readability 0.01g Interface No
Repeatability ±0.02g Power AC 100V-240V/9V battery(not included)
Linearity ±0.03g Packaging Dimensions 11.61"x9.45"x5.51"
Pan Size 150x180mm Gross Weight 4.63 lbs
Number of Displays 1 Windshield No

*To view the full table on mobile, please swipe left or right on the screen.

Precautions

  • Leveling the Balance: Accurate horizontal positioning necessary for repeatable measurementsand exact results. Adjust the leveling feet of the analytical balance until the air bubbleinthe indicator is centered.
  • Warm-Up Requirement: For accurate results, the balance must warm up for at least 30 minutes after being powered on or after a power outage longer than 30 minutes, to reach the proper operating temperature before calibration or use.(For warm-up time details, refer to the user manual or contact support.)
  • Stability: Place the balance on a stable, vibration-free surface, away from drafts and electromagnetic interference. It's important to note that high-precision balances are more susceptible to environmental factors, which can affect reading stability.
  • Calibration: Calibrate the balance if it is moved (even within the same room), when ambient conditions change, and before each use. If pressing the "CAL" button has no effect, ensure you are pressing and holding it. For most models, calibration requires a long press rather than a quick tap.(Refer to the manual for specific instructions).

Troubleshooting

Problem Cause Solution
Display not working No power supply Plug in the adapter
Display shows
"horizontal line"
Object weight below minimum threshold, taring issues exist, or balance is not properly calibrated. Make sure item being weighed is at least 10mg. Make sure receptacles have been tared, and the balance has been properly calibrated.
Display shows
"horizontal line"
ltem being weighed is over maximum allowable weight. Make sure balance is properly calibrated, and make sure item is below maximum allowable weight.
Display shows "Err-1" Power issues with the balance. Machine may have a poor power connection. Check the power in the back, and the outlet. Leave machine off for several minutes, unplug fully, then reconnect and beqin again.
Display shows "Err-2" Unstable weighing conditions. Recalibrate machine make sure balance is level, and make sure item being weighed is fully stable.

All Options

Units Readability Model Capacity Calibration Weight Linearity Repeatability Pan Size Wind Shield Calibration Stabilization Time Power Supply
10 types 0.001g USS-DBS64-5 0.01g-500g 200g*1 ±0.005g ±0.002g Φ90mm yes external calibration ≤3s AC/DC
0.01g USS-DBS59-5 0.1g-500g 200g*1 ±0.03g ±0.02g 150x180mm no
USS-DBS59-10 0.1g-1kg 500g*1
USS-DBS59-20 0.1g-2kg
USS-DBS59-30 0.1g-3kg
USS-DBS59-50 0.1g-5kg no
0.1g USS-DBS60-50 1g-5kg no ±0.3g ±0.2g
USS-DBS60-100 1g-10kg
USS-DBS60-150 1g-15kg
* 10 Weighing Units Conversion: g, ct, oz, ozt, lb, TOL, dwt, MM, kg, %