INTRODUCTION
The U.S. Solid USS-ZWC00020 Industrial Water Chiller provides active and stable cooling for 30–150W CO2 laser engraving and cutting systems, 5–25kW high-frequency induction heaters, and other compatible water-cooled equipment. Its compressor-based refrigeration system delivers 1.7kW cooling capacity, while the 20L/min circulation pump and 34m pump head support efficient heat transfer through demanding cooling loops.
With a 5–32°C control range, ±0.5°C temperature stability, and multiple protection functions, this chiller helps maintain consistent equipment performance during extended operation. For TIG/MIG water-cooled torches, please confirm that the required flow rate, pressure, connectors, and cooling load are compatible before use.
FEATURES
APPLICATIONS
SPECIFICATIONS
| Model | USS-ZWC00020 | Brand | U.S. SOLID |
|---|---|---|---|
| Voltage | 110 V or 220V | Cooling Capacity | 1700 W / 5830 BTU/h |
| Total Input Power | 1050 W | Compressor | Hermetic rotary, 600 W motor |
| Refrigerant | R410A | Condenser Material | Copper tube / aluminum fins |
| Evaporator Material | SUS304 stainless steel coil | Control Range | 5°C to 32°C (41°F to 89.6°F) |
| Temperature Stability | ±0.5°C (±0.9°F) | Pump | Magnetic pump, 34 m head / 20 L/min |
| Water Tank Capacity | 7.5 L | Protection | Low water, flow, high/low temperature, cooling fault, overheat, overload, anti-freeze |
| Net Weight | 35 kg | Product Size | 38 × 60 × 48 cm |
CE CERTIFIED QUALITY & SAFETY
FAQ
1. Is this a TIG/MIG welding torch water cooler?
Yes. This industrial water chiller can be used with compatible water-cooled TIG/MIG welding torches. Its compressor-based refrigeration system provides active cooling and stable temperature control. Before use, confirm that the torch system’s required cooling load, flow rate, pressure, hose connections, and operating temperature are compatible with this chiller.
It is also designed for 30–150W CO2 laser equipment and compatible U.S. Solid 5–25kW high-frequency induction heaters.
2. What temperature range can be set?
The controller supports an adjustable 5-32°C water temperature range with ±0.5°C temperature stability under normal working conditions.
3. What water should be used?
Use clean filtered water. Do not use oil, corrosive liquid, flammable liquid, or unapproved coolant.
4. What should I do if an alarm appears?
Stop the connected process load first, check the displayed alarm code, water level, hoses, water flow, and airflow. Do not repeatedly reset the chiller before the cause is corrected.
WARNING
1. Confirm the nameplate voltage and frequency before connecting power.
2. Fill the tank before startup. Never run the pump or chiller without water.
3. Use clean filtered water only. Do not use oil, corrosive liquid, flammable liquid, or unapproved coolant.
4. Install indoors on a level surface, away from rain, splash, direct sunlight, and corrosive air.
5. Keep the air inlet and fan exhaust unobstructed to maintain cooling performance.
6. If an alarm occurs, stop the connected process load and correct the cause before restarting.
7. R410A refrigerant system service should be performed by qualified refrigeration personnel.
8. Before connecting a TIG/MIG torch, verify the torch manufacturer’s requirements for cooling load, flow rate, pressure, hose connections, and operating temperature.

OTHER MODELS
| SKU | JFZWC00001 | JFZWC00002 | JFZWC00003 | JFZWC00004 |
|---|---|---|---|---|
| Voltage | 110V | 110V | 110V | 110V |
| Pump Power | 370 W | 370 W | 370 W | 370 W |
| Current | ≤ 2.2 A | ≤ 2.2 A | ≤ 2.2 A | ≤ 2.2 A |
| Cooling Capacity | 2.8 KW | 1.5 KW | 1.7 KW | 2.6 KW |
| Flow Rate | 7.5 L/min (1.98 GPM) | 7.5 L/min (1.98 GPM) | 7.5 L/min (1.98 GPM) | 7.5 L/min (1.98 GPM) |
| Head / Lift | 35 m | 35 m | 35 m | 35 m |
| Max Pressure | 0.35 MPa | 0.35 MPA | 0.35 MPa | 0.35 MPA |
| Water Capacity | 25 L (6.6 gal) | 10L (2.64 gal) | 12 L (3.17 gal) | 20L (5.28 gal) |
| Inlet Diameter | 15 cm | 3 cm | 3 cm | 15 cm |
| Connector Size | 19 mm | 10mm | 10 mm | 10mm |
| Ambient Temperature | -20~60°C (-4~140°F) | -20~60°C (-4~140°F) | -20~60°C (-4~140°F) | -20~60°C (-4~140°F) |