Halogen Moisture Analyzer, 40-230 °C, 220 g Capacity, 0.0001 g/0.001% Readability, 5 in Touchscreen, RS232, for Food, Grain and Lab Testing

Halogen Moisture Analyzer, 40-230 °C, 220 g Capacity, 0.0001 g/0.001% Readability, 5 in Touchscreen, RS232, for Food, Grain and Lab Testing

SKU: Product SKU: JFVM00005-220G

มี 20 รายการในสต็อกสินค้า

ราคาปกติ $4,487.00 USD
ราคาปกติ ราคาโปรโมชัน $4,487.00 USD
ลดราคา ขายหมดแล้ว
ค่าจัดส่งที่คำนวณในขั้นตอนการชำระเงิน
ดูรายละเอียดทั้งหมด
Halogen moisture analyzer cover image

INTRODUCTION

The U.S. Solid USS-VM00005-220G halogen moisture analyzer combines a 220 g capacity with a 40 to 230 deg C drying range, 0.0001 g weighing readability and 0.001 percent moisture readability. It uses an electromagnetic force weighing sensor, a PT1000 temperature sensor and a glass panel between the lamp and sample area.

The 5 in touchscreen displays drying curves; store 96 methods and 2004 test records, with USB-C data import and export and RS232 printer connectivity. Operates on 110 V AC, 60 Hz with a US plug

FEATURES

Halogen moisture analyzer features

APPLICATIONS

Halogen moisture analyzer applications

CE CERTIFICATION

CE certification

SPECIFICATIONS

Model USS-VM00005-220G Capacity 220 g
Weighing Readability 0.0001 g Moisture Readability 0.001%
Weighing Repeatability Standard deviation up to 3d; d = weighing readability Weighing Sensor Electromagnetic force
Glass Heater Shield Fitted Moisture / Solids Display Range 0–100%
Heating Source 350 W halogen lamp Temperature Setting Range 40–230 °C (104–446 °F)
Temperature Resolution / Setting Step 0.1 °C / 0.1 °C Temperature Sensor / Control PT1000 / PID
Power Supply 110 V AC, 60 Hz, grounded US plug Maximum Instrument Input 500 W (distinct from lamp power)
Display 5 in color touchscreen Heating Programs Standard, gentle, rapid, step
Stopping Modes Automatic, timed, manual Timed Mode Duration 1–99 min; 1-second setting increments
Method Storage Up to 96 custom methods Result Storage Up to 2004 completed records
USB Data Port USB-C data import/export; up to 2000 HTML records per export Calibration External weight calibration; use model-specific prompted mass within capacity; separate compatible temperature calibrator
Stabilization Time None specified Heating Chamber Opening Method Manual
Sample Pan Diameter 90 mm Heating Chamber Height 24.5 mm
Dimensions 23.4 × 35 × 20.5 cm Interfaces RS-232C; USB-C data import/export
RS-232C Settings Asynchronous; 2400 / 4800 / 9600 / 19200 baud; 8 data bits, no parity, 1 stop bit (8N1); ASCII output Operating Ambient Temperature 1–38 °C; ideally 18–25 °C

FAQ

How should the analyzer be prepared before a measurement?

Place it on a firm, level bench, install a clean and dry sample pan, allow at least 30 minutes of powered warm-up, and check or calibrate the weighing system as needed.

Which heating mode should be selected?

Use standard heating for routine samples, gentle heating for heat-sensitive materials, rapid heating for suitable high-moisture samples, and step heating when the validated method requires staged drying.

Why can results vary between repeated tests?

Differences in sample uniformity, sample amount, preparation, starting chamber conditions, temperature, heating program, or endpoint can change the result. Keep these conditions consistent when comparing tests.

Does the displayed moisture result measure water only?

Not necessarily. The result is based on mass lost during heating and may include volatile substances other than water. Validate the method against an appropriate reference method when water-specific results are required.

How should the analyzer be cleaned?

Switch off, unplug, and allow the instrument to cool completely. Clean removable parts and exterior surfaces with a soft, lightly dampened lint-free cloth. Do not immerse the instrument, spray liquid onto it, or use abrasive cleaners or organic solvents.

WARNING

  • Use only the specified 110 V AC, 60 Hz supply and a grounded US power cord. Do not operate the analyzer with damaged wiring or allow liquid to enter the housing or connectors.
  • The heater, chamber, sample pan, and sample can remain hot after testing. Keep ventilation openings clear, maintain at least 1 m (39.4 in) of overhead clearance, and use suitable tools and heat protection.
  • Do not test explosive materials or samples that may react dangerously. Flammable, solvent-containing, toxic, or corrosive samples require a documented safety assessment and suitable extraction before testing.
  • Do not exceed the instrument capacity. Taring does not increase capacity, and a 100 g calibration weight must never be placed on a 62 g model.
  • Switch off, unplug, and allow the analyzer to cool before cleaning, moving, or connecting accessories. Do not open the housing or attempt internal repairs.

USER MANUAL

OTHER MODELS

Explore Our Full Range of Halogen Moisture Analyzers

We offer a variety of models with different weighing capacities and readability levels to meet your testing requirements.

VIEW MODEL SELECTION TABLE
Halogen moisture analyzer cover image

INTRODUCTION

The U.S. Solid USS-VM00005-220G halogen moisture analyzer combines a 220 g capacity with a 40 to 230 deg C drying range, 0.0001 g weighing readability and 0.001 percent moisture readability. It uses an electromagnetic force weighing sensor, a PT1000 temperature sensor and a glass panel between the lamp and sample area.

The 5 in touchscreen displays drying curves; store 96 methods and 2004 test records, with USB-C data import and export and RS232 printer connectivity. Operates on 110 V AC, 60 Hz with a US plug

FEATURES

Halogen moisture analyzer features

APPLICATIONS

Halogen moisture analyzer applications

CE CERTIFICATION

CE certification

SPECIFICATIONS

Model USS-VM00005-220G Capacity 220 g
Weighing Readability 0.0001 g Moisture Readability 0.001%
Weighing Repeatability Standard deviation up to 3d; d = weighing readability Weighing Sensor Electromagnetic force
Glass Heater Shield Fitted Moisture / Solids Display Range 0–100%
Heating Source 350 W halogen lamp Temperature Setting Range 40–230 °C (104–446 °F)
Temperature Resolution / Setting Step 0.1 °C / 0.1 °C Temperature Sensor / Control PT1000 / PID
Power Supply 110 V AC, 60 Hz, grounded US plug Maximum Instrument Input 500 W (distinct from lamp power)
Display 5 in color touchscreen Heating Programs Standard, gentle, rapid, step
Stopping Modes Automatic, timed, manual Timed Mode Duration 1–99 min; 1-second setting increments
Method Storage Up to 96 custom methods Result Storage Up to 2004 completed records
USB Data Port USB-C data import/export; up to 2000 HTML records per export Calibration External weight calibration; use model-specific prompted mass within capacity; separate compatible temperature calibrator
Stabilization Time None specified Heating Chamber Opening Method Manual
Sample Pan Diameter 90 mm Heating Chamber Height 24.5 mm
Dimensions 23.4 × 35 × 20.5 cm Interfaces RS-232C; USB-C data import/export
RS-232C Settings Asynchronous; 2400 / 4800 / 9600 / 19200 baud; 8 data bits, no parity, 1 stop bit (8N1); ASCII output Operating Ambient Temperature 1–38 °C; ideally 18–25 °C

FAQ

How should the analyzer be prepared before a measurement?

Place it on a firm, level bench, install a clean and dry sample pan, allow at least 30 minutes of powered warm-up, and check or calibrate the weighing system as needed.

Which heating mode should be selected?

Use standard heating for routine samples, gentle heating for heat-sensitive materials, rapid heating for suitable high-moisture samples, and step heating when the validated method requires staged drying.

Why can results vary between repeated tests?

Differences in sample uniformity, sample amount, preparation, starting chamber conditions, temperature, heating program, or endpoint can change the result. Keep these conditions consistent when comparing tests.

Does the displayed moisture result measure water only?

Not necessarily. The result is based on mass lost during heating and may include volatile substances other than water. Validate the method against an appropriate reference method when water-specific results are required.

How should the analyzer be cleaned?

Switch off, unplug, and allow the instrument to cool completely. Clean removable parts and exterior surfaces with a soft, lightly dampened lint-free cloth. Do not immerse the instrument, spray liquid onto it, or use abrasive cleaners or organic solvents.

WARNING

  • Use only the specified 110 V AC, 60 Hz supply and a grounded US power cord. Do not operate the analyzer with damaged wiring or allow liquid to enter the housing or connectors.
  • The heater, chamber, sample pan, and sample can remain hot after testing. Keep ventilation openings clear, maintain at least 1 m (39.4 in) of overhead clearance, and use suitable tools and heat protection.
  • Do not test explosive materials or samples that may react dangerously. Flammable, solvent-containing, toxic, or corrosive samples require a documented safety assessment and suitable extraction before testing.
  • Do not exceed the instrument capacity. Taring does not increase capacity, and a 100 g calibration weight must never be placed on a 62 g model.
  • Switch off, unplug, and allow the analyzer to cool before cleaning, moving, or connecting accessories. Do not open the housing or attempt internal repairs.

USER MANUAL

OTHER MODELS

Explore Our Full Range of Halogen Moisture Analyzers

We offer a variety of models with different weighing capacities and readability levels to meet your testing requirements.

VIEW MODEL SELECTION TABLE